Haryana Vidyut Prasaran Nigam Limited Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Haryana Vidyut Prasaran Nigam Limited - HVPNL Tender

Works
Energy, Oil and Gas
Eprocure
Opening Date9 Aug 2024
Closing Date22 Nov 2024
Tender AmountRefer Documents 
Notes
Download

Costs

  • EMD

    ₹ 2,29,57,000
  • Document Cost

    ₹ 11,800
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
BDV testing Kit

3

-

-

... More
Tool Kit

2

-

-

... More
160 MVA, 220/132 kV, 3 Phase Transformer with NIFPES for 160 MVA T/F( to be supplied by HVPNL)

1

-

-

... More
420kV circuit breakers (3 Ph.) with support structures 3150 A, 50 KA without closing resistor

16

-

-

... More
420kv (6core) CT (1 Ph.) Ratio- 3000-2000-500/1-1-1-1-1-1A 3000 A, 50KA with 125% extended current rating

48

-

-

... More
420kV Isolators (double break type) i) 3150A, 50 KA, isolator with one E/S

34

-

-

... More
ii) 3150A, 50 KA, isolator with both side E/S

10

-

-

... More
336 kV Surge Arrester (Gapless)

9

-

-

... More
420kV Bus Post Insulator

23

-

-

... More
400 KV C&R Panels (Simplex type) i. Circuit Breaker control panel without Auto Reclose and transformer Protection Panel (For HV side) with peripheral relay for bus bar protection on 400kV side.

3

-

-

... More
ii. Circuit Breaker control panel with Auto Reclose and Tie protection panel with P.U of future line bay.

2

-

-

... More
i) Extension of existing Fire Protection System (As per technical specification) for 500 MVA Auto-Transformer at 400kV sub-station as per site requirement is in the scope of bidder.

3

-

-

... More
ii) Anti Fire Wall

3

-

-

... More
245 kV Circuit Breakers(3 ph) i) 2500 A, 50 kA

3

-

-

... More
ii) 1250 A,40KA

1

-

-

... More
245 kV T/F I/C CT (1 ph) 50 kA with 125% extended current (I/C T/F CT ) (Ratio 1600-800/1-1-1-1-1A)

9

-

-

... More
220 kV CT for Transformer (Ratio 450-300/0.577-1-1-1-1A)

3

-

-

... More
220KV NCT(for 160MVA)

1

-

-

... More
245 kV Isolator (3 ph) Double break i. 2500A,50 kA,Isolator

6

-

-

... More
ii. 1250 A,40 kA,Isolator

2

-

-

... More
220 kV Surge arrestors i. 216kV, 50KA

9

-

-

... More
ii. 198kV , 40kA

3

-

-

... More
245kV Bus Post Insulator

6

-

-

... More
220 kV C&R Panels with SAS i) Circuit Breaker control panel without Auto Reclose for T/F I/C for 500MVA, 400/220kV T/F.

1

-

-

... More
ii) Circuit Breaker control panel without Auto Reclose and transformer Protection Panel (For HV side) with peripheral relay for bus bar protection on 220kV side for 160MVA, 220/132kV T/F.

1

-

-

... More
iii) Circuit Breaker control panel without Auto Reclose and transformer Protection Incomer Panel (For LV side) with peripheral relay for bus bar protection on 220kV side .

2

-

-

... More
132kv Bus Post insulator

2

-

-

... More
132kv 1000 Amps circuit breaker

1

-

-

... More
132kv 1000 Amps isolator

2

-

-

... More
132kv CVT (if required as per site)

1

-

-

... More
132kv surge Arrestor

3

-

-

... More
132 kV CT For Transformer I/C (750-500/0.577-1-1-1A)

3

-

-

... More
132 kV C&R Panels with SAS Circuit Breaker control panel without Auto Reclose for T/F I/C for 160MVA, 220/132kV T/F.

1

-

-

... More
Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area including all accessories, cables etc. as per HVPNL Technical specification .

37

-

-

... More
Fire Fighting equipments as per tech. spec. i) 22.5 Kg Capacity FE CO2 type, Trolley Mounted

2

-

-

... More
ii) 25 Kg Capacity FE DCP type, Trolley Mounted

2

-

-

... More
iii) Fire Buckets(12 Nos with stand in one set)

1

-

-

... More
Power cables (XLPE & PVC) as per site requirements.

3

-

-

... More
Complete substation automation system for 400/220/132 kV substations including hardware (along with transducers) & software, if required for present scope of work ( 1 no.500 MVA 400/220/33 kV T/F Bay and 1 no. 160 MVA 220/132 kV T/F Bays ) (Refer Note 1 also)

1

-

-

... More
Complete substation automation system for 400/220kV substations including hardware (along with transducers) & Software, if required, for present scope of work ( 1 no.500 MVA 400/220/33 kV T/F Bay)

2

-

-

... More
Armoured copper control cables (PVC) of following sizes 7Cx4mm2, 4Cx4mm2, 2Cx4mm2, 2Cx6mm2, 3Cx2.5mm2, 7Cx2.5mm2, 10Cx2.5mm2 & 16Cx2.5mm2 with junction box for 400kV ,220kV and 132kv side with associated accessories like clamps, PVC ferrules, glands, lugs, fibre cleat/aluminum clamp/bolt/washers etc. as per specification.

3

-

-

... More
Dismantlement of existing 400kV switchgear equipments at 400KV Sub-station Dhanonda i. 420kV circuit breakers (3 Ph.) with support structures

11

-

-

... More
ii. 420kV current Transformer

33

-

-

... More
iii. Isolators (double break type) with one Earth Switch

22

-

-

... More
iv. Isolators (double break type) with both side Earth Switch

8

-

-

... More
v. Aluminium Tube

1

-

-

... More
vi. All the above equipments along with associated jumpers, hardware fittings, conductor etc.as per site.

1

-

-

... More
Bolted type 400 kV single suspension string assembly with Silicon rubber Polymer Composite Insulators (E&M strength 120 KN) with all hardware accessories including ball & socket connection accessories for Twin Tarantula conductor.

21

-

-

... More
Bolted type 400 kV Double tension string assembly with Silicon rubber Polymer Composite Insulators (E&M strength 120 KN) with all hardware accessories including ball & socket connection accessories for twin tarantula conductor.

24

-

-

... More
Bolted type 220 kV single suspension string assembly with Silicon rubber Polymer Composite Insulators (E&M strength 90 KN) with all hardware accessories including ball & socket connection suitable for Twin Tarantula (string).

18

-

-

... More
Bolted type 220 kV Single tension string assembly with Silicon Rubber Polymer Composite Insulators (E&M strength 90 KN) with all hardware accessories including ball & socket connections and tension clamp sets suitable for Twin Tarantula (string).

42

-

-

... More
Bolted type 132 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90KN) with all hardware accessories including ball & socket connection suitable for Twin Tarantula (string).

18

-

-

... More
Bolted type 132 kV Single Tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 90 KN) with all hardware accessories including ball & socket connection suitable for Twin Tarantula (string).

36

-

-

... More
Earthing material – 40mm MS rod & G.I. earthing flat for connecting all the equipments with existing main earthmat, risers, & independent earthing of T/F up to water level. Suitable arrangements as per actual site conditions shall be made in existing earthmat to take care of 50kA fault level as per technical specification and IEEE-80.

3

-

-

... More
Erection Hardware for 400/220 kV/132kv Insulator strings, Disc Insulators, Hardware, conductor(s),Al tube(s), Earthwire(s), corona bell ,bus-bar materials,Earthing material,Risers,Auxilliary earthmat ,Cable trays,Bay MB

3

-

-

... More
Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 150x25x2 mm, 100x25x2 mm and 75x25x2 mm and G.I conduits of 50/100mm diameter from equipment to main trench as per technical requirement.

3

-

-

... More
Clamps & connectors including equipment connectors, cable supporting angles/channels, cables, C-Wedge connectors, spacers, lug glands, firefighting equipment ,Junction box,Pipes for equipments and lighting, lighting PVC ferrules all accessories etc. as per GELO and specification.

3

-

-

... More
Dismantlement of bus & erection and jumpering with equipments and all other equipment/conductor etc dismantlement which has not been specified but is necessary to complete the work

1

-

-

... More
Tarantula Conductor

10000

-

-

... More
AL Tube Bus bar (4.5 inch)

1700

-

-

... More
GS Earth wire (7/3.66) as per specification

3

-

-

... More
U-bolt 20mm dia

3

-

-

... More
Bay marshalling Kiosk with mounting structure for 400kV side (Front side with 350 tb for control circuit and rear side power circuit)

4

-

-

... More
Bay marshalling Kiosk with mounting structure for 220kV side (Front side with 300 tb for control circuit and rear side power circuit)

4

-

-

... More
Bay marshalling Kiosk with mounting structure for 132kV side

1

-

-

... More
Item for associated Structure work ‘Lattice Type Steel Structure. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 400/220kV/132kV switchyard fabricated from steel conforming to IS:2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner. Main substation Tower and beam Tower type AT-1

7

-

-

... More
Tower type AT-3

2

-

-

... More
Beam Type AB-1

5

-

-

... More
Tower type BT-1

5

-

-

... More
Tower type BT-3

5

-

-

... More
Beam type BB-1

5

-

-

... More
400 kV Pipe Structures (Standard) i. CT (Drg. No. HTD/ST-197)

15

-

-

... More
ii. Isolators ( Drg. No. HTD/ST-196)

14

-

-

... More
iii. Surge Arrestor (Drg. No. HTD/ST-195)

9

-

-

... More
iv. BPI (Drg. No. HTD/ST-193)

23

-

-

... More
220 kV Lattice Structure (Standard) i. CT (Drg. No. HTD/ST-147)

12

-

-

... More
ii. Isolators (Drg. No. HTD/ST-170)

8

-

-

... More
iii. BPI (Drg. No. HTD/ST-116 R3)

6

-

-

... More
iv. Surge Arrestor ( Drg. No. HTD/ST-93 R)

12

-

-

... More
v. 220 kV NCT drawing No. HTD/ST-150

1

-

-

... More
132KV Structure i. CT (Drg. No. HHW/ST-67)

3

-

-

... More
ii. Isolators (Drg. No. HTD/ST-90R)

2

-

-

... More
iii. BPI (Drg. No. HTD/ST144)

2

-

-

... More
iv. Surge Arrestor (Drg. No. HSW/ST- 63R)

3

-

-

... More
v. CVT(Drg. No. HHW/ST- 67)

1

-

-

... More
LIST OF MANDATORY SPARES FOR 400kV DHANONDA, 400kV NAWADA and 400kV KIRORI A. 420 kV SF-6 circuit Breaker i. One pole complete without closing resistor, grading capacitor (if applicable) complete with column and interrupter with MB & operating mechanism and without support structure

1

-

-

... More
ii. SF-6 Gas (40% of ordered quantity)

1

-

-

... More
iii. Trip coil with resistor

2

-

-

... More
iv. Closing coil with resistor

2

-

-

... More
v. Terminal pad and connectors

1

-

-

... More
vi. Molecular filter for SF6 Ckt for 1 pole of CB

2

-

-

... More
vii. Density /pressure monitor for SF-6CKt for 1 pole of ckt breaker

1

-

-

... More
viii. Corona rings of each type

1

-

-

... More
ix. Fixed moving and arching contacts including insulating nozzels for one pole of CB

1

-

-

... More
x. Relays, power contractors, switch fuse units, limit switches, push buttons, timers and MCBs etc. (1 no of each type)

1

-

-

... More
xi. Closing Coil assembly

1

-

-

... More
xii. Trip Coil assembly

1

-

-

... More
xiii. Set of control valves (of each type)

1

-

-

... More
xiv. Pressure switches of each type ( 1 CB)

1

-

-

... More
xv. Pressure Gauge with coupling device of each type

1

-

-

... More
xvi. Aux switch assembly

1

-

-

... More
xvii. Operation counter

1

-

-

... More
xviii. All type of coupling for SF6 gas

1

-

-

... More
xix. Rubber Gasket “O Ring” and seal (complete replacement for 1 phase of 420kV SF6 Circuit Breaker

1

-

-

... More
Spring Operating Mechanism xx. Complete Spring Operating Mechanism

1

-

-

... More
xxi. Closing Dashpot

1

-

-

... More
xxii. Opening Dashpot

1

-

-

... More
xxiii. Opening Catch Gear

1

-

-

... More
xxiv Closing Catch Gear

1

-

-

... More
B. 420 kV Double Break Isolator i. One complete pole with support insulators excluding structure & motor operating mechanism

1

-

-

... More
ii. Copper contact fingers for female & male contacts

2

-

-

... More
iii. Terminal pad with connectors

1

-

-

... More
iv. Relays, power contactors, MCBs switch fuses, push buttons and resistors for electrical control ckt as per approved schematic

1

-

-

... More
v. Timers. Key interlock, push button switch, limit switch, aux. switches, corona shield, motor having bearing assembly etc.

2

-

-

... More
vi. Support Insulator

1

-

-

... More
C. 336 kV Surge Arrester i. 336 kV Surge Arrester complete with Insulating base and terminal connectors

3

-

-

... More
ii. Surge Counters/monitors

3

-

-

... More
D. Transformers protection panel spares i. Transformers differential protection relay including all aux. CTs

3

-

-

... More
ii. Restricted earth fault protection relay with non-linear resistor

3

-

-

... More
iii. Back up for protection relay with 3 O/C and E/F element

3

-

-

... More
iv. Over fluxing relay, if separate relay is provided in the approved C&R panel

3

-

-

... More
v. Over load spare relay with timer, if separate relay is provided in the approved C&R panel

3

-

-

... More
E. Substation Automation System i. Intelligent electronics device (IED)

3

-

-

... More
ii. Set of each type optic fire cables of length of longest section used

3

-

-

... More
iii. Set of connectors (one of each type) for optic fibre cables

3

-

-

... More
iv. Ethernet switch

3

-

-

... More
F. 420 kV CT

3

-

-

... More
G. 245kV SF-6 Ckt Breaker i. One pole complete with of 2500 A CB with pole column and interrupter with MB & operating mechanism, grading capacitor (if required) and without support structure

3

-

-

... More
ii. “O” rings, gaskets, Seals for operating mechanism

3

-

-

... More
iii. Trip coil with resistor

3

-

-

... More
iv. Closing coil with resistor

3

-

-

... More
v. Terminal pad and connectors

3

-

-

... More
vi. Molecular filter for SF6 Ckt for 1 pole of CB

3

-

-

... More
vii. Density /pressure monitor for SF6 ckt for 1 pole of ckt breaker

3

-

-

... More
viii. Corona ring of each type

3

-

-

... More
ix. Fixed moving and arcing contacts including insulating nozzles for one pole of CB.

3

-

-

... More
x. Relays, power contractors , switch fuse units , limit switches , push buttons m, timers and MCBs etc

3

-

-

... More
xi. Closing Coil assembly

3

-

-

... More
xii. Trip Coil assembly

3

-

-

... More
xiii. Set of control Valve (of each type)

3

-

-

... More
xiv. Pressure switches with (1 CB)

3

-

-

... More
xv. Pressure gauges with coupling device of each type

3

-

-

... More
xvi. Aux switch assembly

3

-

-

... More
xvii. Operation counter

3

-

-

... More
xviii. All type of coupling for SF6 Gas

3

-

-

... More
Spring Operating Mechanism xix. Complete Spring Operating Mechanism

3

-

-

... More
xx. Closing Dashpot

3

-

-

... More
xxi. Opening Dashpot

3

-

-

... More
xxii. Opening Catch Gear

3

-

-

... More
xxiii. Closing Catch Gear

3

-

-

... More
H. 245 kV Double break isolator i. One complete pole of 245 KV 2500A Isolator along with support insulators & operating mechanism.

3

-

-

... More
ii. Copper contact fingers for female & male contacts.

3

-

-

... More
iii. Terminal pad with connectors

3

-

-

... More
iv. Relays, power contactors, switch tests & push buttons

3

-

-

... More
v. Motor with gear assembly and bevel gear assembly

3

-

-

... More
vi. Hinge pins

9

-

-

... More
vii. Corona shield rings

3

-

-

... More
viii. Bearing

3

-

-

... More
ix. Current Carrying assembly

3

-

-

... More
x. Limit switch

6

-

-

... More
I. 216 kV Surge Arrester i. 216 KV Surge Arrester Complete with Insulating base and terminal connectors

3

-

-

... More
ii. Surge Counters

3

-

-

... More
J. 220 kV T/F I/C CT

3

-

-

... More
K. LIST OF MANDATORY SPARES FOR 500 MVA AUTO TRANSFORMER (AS APPLICABLE) i. Oil cooler pump with motor

3

-

-

... More
ii. Buchholz relay complete with float and contacts (main Tank)

3

-

-

... More
iii. Local & remote WTI complete with sensing device & contacts

3

-

-

... More
iv. Oil temperature indicators with contacts & sensing device

3

-

-

... More
v. Pressure relief device

3

-

-

... More
vii. Magnetic oil level gauge

3

-

-

... More
viii. Cooler fan with motor

3

-

-

... More
ix. Starters, contactors, switches & relays for electrical control panels (one set of each type)

3

-

-

... More
x. Set of valves (complete set for one transformer)

3

-

-

... More
xi. Fuses & MCBs ( one set complete for replacement for one transformer)

3

-

-

... More
xii. Oil sampling bottles (Stainless Steel, 1 Ltr)

18

-

-

... More
xiii. Oil storage tank (15 KL)

10

-

-

... More
xiv. Indicating Lamps (1Set consisting of complete replacement for one transformer).

3

-

-

... More
xv. Aux. Transformer for control of cooler control cabinet and OLTC (if applicable)

3

-

-

... More
xvi. Breather assembly (one of each type ) for conservator and OLTC

3

-

-

... More
xvii. Remote tap position indicator

3

-

-

... More
xviii. Oil flow indicator with flow switch

3

-

-

... More
xix. Oil surge relay for OLTC

3

-

-

... More
xx. 420kV Bushing with metal parts, gasket and lifting tools

3

-

-

... More
xxi. 245kV Bushing with metal parts & gasket

3

-

-

... More
xxii. 52kV Bushing with metal parts & gasket (if applicable)

3

-

-

... More
xxiii. Neutral Bushing with metal parts & gasket

3

-

-

... More
xxiv. Cartridge for Online insulating oil drying system.

3

-

-

... More
Civil Portion 1. Foundations Supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & drawings attached with the tender document including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc. and other items not mentioned herein but required for the completion of work. A. Gantry Towers i) AT-1

6

-

-

... More
ii) AT-3

1

-

-

... More
B. Equipment 400 kV side i) 400kV CT

15

-

-

... More
ii) 400kV L&E/Isolator

14

-

-

... More
iii) 400kV LA

9

-

-

... More
iv) 400kV Post

23

-

-

... More
220 Kv Side i) 220 kV LA

9

-

-

... More
ii) 220kV CT

9

-

-

... More
iii) 220kV Post

6

-

-

... More
iv) 220kV L&E/Isolator

7

-

-

... More
v) 220kV NCT

1

-

-

... More
132 kV Side i) 132 kV Post Insulator

2

-

-

... More
2. Breaker Foundation Design, engineering, supply of labour, material for construction of breaker foundations including all associated works such as PCC, RCC, structural steel, steel reinforcement, form work etc. or any other items not specifically mentioned herein but required for completion of work as per approved equipment(s) and technical specifications. i) 400 kV Circuit Breaker

5

-

-

... More
ii) 220kV Circuit Breaker

4

-

-

... More
iii) 132kV Circuit Breaker

1

-

-

... More
3. Transformer Foundation i) Design, Engg., supply of labour, material and construction of T/F foundation including radiator foundations etc. complete transformer foundations including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications. In case additional foundation is/are required as per approved equipment drawing, the same shall be constructed by the successful bidder without any extra cost to HVPNL. Such drawing(s) shall, however, be got approved from HVPNL. 500MVA,400/220kV T/F block foundation including radiator foundation and oil pit system etc. complete in all respect

3

-

-

... More
ii) Design, Engg., supply of labour, material and construction of radiator foundation including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications. In case additional foundation is/are required as per approved equipment drawing, the same shall be constructed by the successful bidder without any extra cost to HVPNL. Such drawing(s) shall, however, be got approved from HVPNL. 160 MVA T/F, 220/132kV Radiator foundation including associated foundations for NIFPES system complete in all respect.

1

-

-

... More
4. OUTDOOR CABLE TRENCHES Supply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works as per approved Trench layout plan, HVPNL drgs. & tech. specs. complete in all respect. 400 kV S/Stn. Dhanonda i) D-Type Trench

225

-

-

... More
ii) E-Type Trench

285

-

-

... More
iii) F-Type Trench

45

-

-

... More
iv) G-Type Trench

45

-

-

... More
v) Trench Culvert

1

-

-

... More
5. Site Surfacing PCC WITH GRAVEL (FRESH) 5.1 Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates & spreading 100mm thick layer of 40mm nominal size uncrushed/crushed/broken stone/ pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm size uncrushed/crushed/ broken stone/pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge.

2540

-

-

... More
5.2 ONLY GRAVEL Providing, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge.

2910

-

-

... More
5.3 PCC with existing gravel Collection, screening, cleaning & stacking of existing laid stone ballast (gravel) & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates & re-laying the collected gravel in 100mm thick layer over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm size uncrushed/crushed/ broken stone/pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge, only the gravel laid a fresh will be measured and paid.

10250

-

-

... More
6. RCC Antifire wall Design Engineering & construction of RCC anti fire wall of suitable height & length between 500 MVA T/F and all associated works including supply of labour, material, cement, reinforcement steel, steel form work etc. as per technical specification.

3

-

-

... More
7. AC Kiosk (RCC Framed Structure) Design, Engineering (architectural and structural drawings of AC Kiosk room), supply of labour, material and construction of AC Kiosk room on RCC framed structure including Anti-Termite treatment, plinth protection, electrification (Ceiling LED tubes with fitting, modular switches, boxes, AC, electric wire etc.), acrylic emulsion and weather proof (exterior acrylic paint), aluminum work (doors/windows/ventilators frames etc), false ceiling, floor finishing,indoor RCC cable trenches,double brick wall with 50mm thick glass/mineral wool insulation complete in all respect as per technical specification. Items, which are not mentioned but required for completion of work shall be provided by the successful bidder without any extra cost. i) 400 kV side

4

-

-

... More
ii) 220kV Side

4

-

-

... More
iii) 132kV Side

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.