Haryana Vidyut Prasaran Nigam Limited Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 60,56,000Document Cost
₹ 11,800Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_HBC_245556_1Bid Award Id
ViewTender No
EPC-D-62 dated 10.11.2022Tender Authority
Haryana Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://www.hvpn.org.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Shifting raising the height realignment creation of 220 kV and 66 kV transmission lines in Palwal area.
technical specification electrical
BOQ Items
220kV Special extn (MD+15m) type M/C tower (without stub)
1
-
-
220kV M/C “MB” type Tower (KRR Design)
2
-
-
+3m extn. Only
1
-
-
220kV M/C “MC” type Tower (KRR Design)
1
-
-
220kV M/C “MD” type Tower (KRR Design)
14
-
-
+3m extn. Only
5
-
-
'+6m extn. Only
6
-
-
aux-cross arm only (set of 3)
3
-
-
Auxiliary Cross-arm only (set of 6)
2
-
-
220kV Special extn (MD+9m) type M/C tower
3
-
-
220kV Special extn (MD+15m) type M/C tower
2
-
-
220kV D/C “DA” type Tower (TATA design)
24
-
-
i) +3m extn. Only
12
-
-
ii) +6m extn. Only
6
-
-
220kV D/C DB Type (TATA Design) tower
4
-
-
+3m extn. Only
2
-
-
220kV D/C DC Type (TATA Design) tower
10
-
-
+3m extn. Only
2
-
-
+9m extn. Only
2
-
-
220kV D/C “DD” type Tower (TATA design)
9
-
-
i) +3m extn. Only
3
-
-
ii) +6m extn. Only
1
-
-
220kV D/C Gantry
2
-
-
66kV D/C “DA” type Tower (KRR design)
7
-
-
+3m extn. Only
2
-
-
+6m extn. Only
1
-
-
66kV D/C “DB” type Tower (KRR design)
4
-
-
+3m extn. Only
2
-
-
66kV D/C “DC” type Tower (KRR design)
3
-
-
+6m extn. Only
2
-
-
66kV D/C “DD” type Tower (KRR Design)
12
-
-
+3m extn. Only
3
-
-
+6m extn. Only
2
-
-
+12 m extn. Only
2
-
-
Extra cross-arm only (Set of 3)
1
-
-
Supply of earthing of towers Pipe type
105
-
-
Supply of following Tower accessories
i) Danger Plate
101
-
-
ii) Number Plate
101
-
-
iii) Phase Plate (set of 3)
164
-
-
iv) Circuit Plate (set of 2)
117
-
-
v) Bird Guard (Set of 3)
66
-
-
vi) Anti-climbing device
101
-
-
vii) Glow plate
8
-
-
LINE MATERIAL Conductor (Zebra)
113.1
-
-
Conductor (Moose)
5.65
-
-
Earth wire 7/3.15
1.65
-
-
220kV Silicon Rubber Polymer Insulator strings or Anti-fog* i) 90 kN
9
-
-
i) 70 kN
156
-
-
ii) 120 kN
300
-
-
ii) 160 kN
252
-
-
220kV Bus Post Insulator
12
-
-
66kV Silicon Rubber Polymer Insulator strings or Anti-fog* i) 70 kN
60
-
-
ii) 90kN
6
-
-
iii) 120 kN
324
-
-
Hardware Fittings for ACSR Moose i) Single ‘I’ Suspension String
3
-
-
ii) Single pilot suspension string
12
-
-
iii) Single Tension string
132
-
-
iv) Double tension string
15
-
-
Hardware Fittings for ACSR Zebra i) Single ‘I’ Suspension String
186
-
-
ii) Single Tension string
540
-
-
iii) Single pilot suspension string
30
-
-
iv) Double tension string
42
-
-
Hardware Fittings for ACSR wolf conductor i) Single Tension string
12
-
-
Accessories equivalent to ACSR Moose conductor i) Mid Span Compression Joint for conductor
16
-
-
ii) Repair sleeves for conductor
5
-
-
iii) Vibration damper for ACSR Moose conductor
408
-
-
Accessories equivalent to ACSR Zebra conductor i) Mid Span Compression Joint for conductor
74
-
-
ii) Repair sleeves for conductor
21
-
-
iii) Vibration damper for ACSR Zebra conductor
1524
-
-
Earthwire accessories: i) Vibration damper for earthwire 7/3.15mm
44
-
-
ii) Tension Clamp for earthwire 7/3.15mm
22
-
-
iii) Flexible copper bond
44
-
-
Accessories for ACSR wolf conductor i) Mid Span Compression Joint for ACSR Wolf conductor
3
-
-
OPGW 24F (DWSM, G.652D) (equivalent to Earth wire 7/3.15mm in all respect) matching with existing 24F OPGW
18.88
-
-
Hardware set for above 24 Fiber OPGW fiber optic (equivalent to Earth wire: 7/3.15mm in all respect) cabling including all cable fittings & accessories except joint box.
20
-
-
Joint Box 24F fiber OPGW to OPGW (as applicable)
8
-
-
OPGW (48 fiber) (DWSM). G 652D) (equivalent to Earth wire 7/3.15mm in all respect) which includes following portions:-(i) Tower No. 188 of 220kV Sohna Road-Rangla Rajpur line to Gantry of 220kV S/Stn., Roj-ka-Meo.
1.8
-
-
Hardware set for above 48 Fiber OPGW fiber optic (equivalent to Earth wire: 7/3.15mm in all respect) cabling including all cable fittings accessories except joint box.
2
-
-
FODP 48F: Indoor type, rack mounted with FCPC coupling and pig tails (5mtrs Each) as applicable for 220kV S/Stn.,Roj-ka-Meo.
4
-
-
Joint Box 24F fiber OPGW to OPGW (2 way joint Boxes) (as applicable) (Quantity may varies as per drum schedule of OPGW)
1
-
-
Joint Box 48F (3 way joint Box) OPGW to OFAC (as applicable)
1
-
-
Joint Box (48 Fiber) OPGW to FOAC (as applicable for 220kV Roj-ka-Meo.)
1
-
-
Fiber optic Approach cable, 48 fibers (DWSM)
1
-
-
PLB HDPE Ducts of suitable size & strength alongwith all accessories for Fiber optic Approach cable, 48 fibers(DWSM)
1
-
-
Fiber optic Approach cable, 24 fiber (DWSM) along with PLB HDPE Ducts of suitable size & strength and all accessories
2
-
-
Joint Box (24 fiber) OPGW to FOAC
4
-
-
Wideband Communication Equipment and spares
Telecom equipment as required for 66kV D/C line from 220kV S/Stn., Meerpur Kurali to 66kv S/Stn., Hassanpur.
SDH Equipment (STM – 16 MADM upto 5 MSP protected directions) Base Equipment (Common cards, Cross connect/control cards, optical base cards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc. fully equipped excluding (ii) & (iii) below
2
-
-
Optical Interface Cards/SFP S4.1 SFP (the quantities will be decided at the time of detail engineering)
8
-
-
Tributary cards: E1 Interface card (Min. 32 interfaces per card)
4
-
-
Ethernet Interface 10/100 Base T with Layer-2 switching (min8 interfaces per card)
4
-
-
Gigabit Ethernet (Layer 2) Interface (min 2 nos)
2
-
-
Equipment Cabinet with DDF and all installation accessories
2
-
-
VOIP telephone instrument with one common switch(min. 8 port) compatible with SLDC
2
-
-
Integration of the Equipment with existing network Note: Above quantity covers the requirement of remote station as well.
2
-
-
Optical Interface Cards/SFP S4.1 SFP (the quantities will be decided at the time of detail engineering)
2
-
-
Tributary cards E1 Interface card ( Min.32 interfaces per card)
2
-
-
Ethernet Interface 10/100 BaseT with Layer-2 switching (min 8 interfaces per card)
2
-
-
Gigabit Ethernet (Layer 2) Interface (min 2 nos)
2
-
-
Pre Connectorized Optical Fibre Patch Cords (10 Mtrs.)-Pack of six Patch cords
2
-
-
Transportation & Erection Only of following design of towers i) 220kV D/C DD Type TATA Design
1
-
-
Transportation & Erection of 220kV Silicon Rubber Polymer Insulator strings from site store for its erection i) 90 KN
30
-
-
ii) 160 KN
144
-
-
Transportation & Erection of ACSR Moose Conductor along with Accessories i) ACSR Moose
18.15
-
-
ii) Single ‘I’ Suspension String
9
-
-
iii) Single Tension string
144
-
-
Dismantlement of existing towers of LILO of one ckt of 66kV D/C Panchgaon-Mohammedpur Ahir at Tauru s/stn. The dismantlement of tower shall also include dismantlement of Stub concrete upto a depth of 1M (one meter) from Natural Ground level, back filling, compaction and clearing the site of debris as per satisfaction of field office. a) 66kV D/C DA+0 KRR Design
2
-
-
b) 66kV D/C DD+0 KRR Design
1
-
-
c) 66kV D/C DD+3 KRR Design
1
-
-
d) 66kV D/C DD+12 KRR Design
2
-
-
Dismantlement of towers of part section of existing 66kV S/C Sohna-Taoru line. The dismantlement of tower shall also include dismantlement of Stub concrete upto a depth of 1M (one meter) from Natural Ground level, back filling, compaction and clearing the site of debris as per satisfaction of field office. a) 66kV S/C SA+0 HSEB Design
2
-
-
Dismantlement of existing towers of 66kV D/C Roj ka Meo-Nuh line (in RoW of 66kv S/C Sohna-Nuh line). The dismantlement of tower shall also include dismantlement of Stub concrete upto a depth of 1M (one meter) from Natural Ground level, back filling, compaction and clearing the site of debris as per satisfaction of field office. a) 220kV S/C SC+6 HSEB Design
2
-
-
Dismantlement of existing ACSR Zebra conductor and earthwire complete with H/W fittings, insulators for above portion of line and their transportation & proper stacking at any dedicated store of HVPNL.
1.28
-
-
Dismantlement of existing ACSR wolf conductor and earthwire complete with H/W fittings, insulators for above portion of line and their transportation & proper stacking at any dedicated store of HVPNL.
0.9
-
-
Dismantlement of existing towers of 220KV D/C Sector-72 (now Sohna Road)-Rangala Rajpur line. The dismantlement of tower shall also include dismantlement of Stub concrete upto a depth of 1M (one meter) from Natural Ground level, back filling, compaction and clearing the site of debris as per satisfaction of field office. a) 220kV D/C DA+0 TATA Design
1
-
-
b) 220kV D/C DC+3 TATA Design
1
-
-
c) Dismantlement of existing ACSR Moose conductor 0.5sq” and earthwire complete with H/W fittings, insulators, for above portion of line and their transportation & proper stacking at any dedicated store of HVPNL.
0.86
-
-
Detailed Survey
25
-
-
Furnishing bore log data
25
-
-
Construction of tower foundations as per HVPNL Drgs & Specifications for 0 to 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. (i) 220kV 'MB' type Tower (KRR Design) classified as - Wet
2
-
-
ii)220kV 'MC' type Tower (KRR Design) classified as - Wet
1
-
-
iii) 220kV M/C 'MD' type Tower (KRR Design) classified as - Wet
14
-
-
iv) 220kV D/C 'DA' type Tower (TATA Design) classified as - Wet
24
-
-
v) 220kV D/C 'DB' type Tower (TATA Design) classified as - Wet
4
-
-
vi) 220kV D/C 'DC' type Tower (TATA Design) classified as - Wet
8
-
-
vii) 220kV D/C 'DD' type Tower (TATA Design) classified as - Wet
9
-
-
vi) 220kV D/C Gantry
2
-
-
Construction of tower foundations as per HVPNL Drgs& Specs for 0 to 6 Mtr. Extn , more than +6M and up to +12M extension, including excavation, concreting, supply and placement of steel Reinforcement/Material and backfilling completed in all respect.
i) 66kV D/C 'DA' type Tower (KRR Design) classified as - Wet
7
-
-
ii) 66kV D/C 'DB' type Tower (KRR Design) classified as - Wet
4
-
-
iii) 66kV D/C 'DC' type Tower (KRR Design) classified as - Wet
3
-
-
iv) 66kV D/C 'DD' type Tower (KRR Design) classified as - Dry
1
-
-
- Wet
11
-
-
Construction of tower foundations as per HVPNL Drgs & Specifications for above 06 Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. i) 220kV D/C 'DC' type Tower (TATA Design) classified as - Wet
2
-
-
(ii) 220kV 'MD' type Tower (KRR Design) classified as - Wet
5
-
-
Dewatering of subsoil water for lowering of water table to enable excavation of earth, concreting for foundations/stub and backfilling, by boring of tube wells or deploying well point system so that continuous lowering of water table is made till completion of work, without disturbing the soil characteristics. The rate shall include all type of expenditure for required dewatering arrangements and irrespective of type of tower including extensions if any i.e. KRR design or TATA design.
37
-
-
Protection Measure Brick masonry in 1:4 cement sand mortar including excavation
14
-
-
Earth filling, compaction, leveling etc inside revetments
12
-
-
M-20 (1:1½ :3 mix) concrete for top seal cover, for revetment etc.
7
-
-
Lean concrete (1:3:6)
5
-
-
Lean concrete (1:4:8)
9
-
-
RCC 1:1.5:3 (M20) including all material, labour, excavation, cutting and placing of steel, centering & shuttering, concreting etc. complete in all respect.
17
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements