Haryana Vidyut Prasaran Nigam Limited Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 77,54,551Document Cost
₹ 11,800Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_HBC_245554_1Bid Award Id
ViewTender No
EPC-D No. 66/PDCTender Authority
Haryana Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://etenders.hry.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
220kv Isolater without E/Switch
14
-
-
220kv Surge Arrestor
18
-
-
220kv Post Insulator
14
-
-
220KV CTs for line & Bus Coupler(1200-800-400/1-1-1-1-1A)
15
-
-
220KV CT for Transformer (450-300/0.577-1-1-1-1A)
6
-
-
220KV CVT
4
-
-
220kv C&R Panels
a) Line Protection and circuit Breaker Panel (With Auto Reclose)
4
-
-
b) Transformer Protection and Ckt Breaker control Panel (Without Auto Reclose)for both HV side of 220/33kv T/F (one for each transformer)
2
-
-
c) Bus Coupler cum Bus Bar Protection and Ckt Breaker control Panel without auto reclose (Double Bus Bar)
1
-
-
220kv NCT (450-300/1A)
2
-
-
220kv PT
6
-
-
Time Sychronization euipment
1
-
-
33 KV VCB 2000A for Bus Coupler & Incommer
3
-
-
33 KV VCB 630A
10
-
-
33 KV Capacitor VCB 630A
2
-
-
33 KV LA's
42
-
-
33 KV C&R Panels
a) 33KV Transfomer I/C C&R Panel (Without Auto Reclose) with one no. special energy meter
2
-
-
b) 33KV Line Protection and circuit Breaker Panel (Without Auto Reclose)
10
-
-
c) 33KV Ckt Breaker control Panel (Without Auto Reclose) and capacitor protection panel
2
-
-
d) 33 KV Bus Coupler Protection and Ckt Breaker control Panel( without auto reclose) (Double Bus Bar)
1
-
-
33 KV Isolator 630A
28
-
-
33 KV Isolator 2000A for bus coupler & incomer
6
-
-
33 KV L&E Switch for line & cap. Bank
12
-
-
33 KV PT
6
-
-
33 KV line cum capacitor CT (400-300/5-1A)
36
-
-
33 KV I/C Transformer CT (2000-1000/0.577-5-5-1A)
6
-
-
33 KV Bus Coupler CT (2000-1000/5A)
3
-
-
33 KV NCT(2000-1000/5A)
2
-
-
1X21.744 MVAR 33KV Capacitor Bank along with Str. & allied equipment (NCT, Series Reactor etc.,) as per specification
2
-
-
220V 200AH Battery
2
-
-
220 V Battery Charger
2
-
-
220V D.C.D.B. suitable for 200AH Battery
2
-
-
415V LT AC MCCB Board 500A
1
-
-
33/0.4 kv Station Transformer 200 KVA with CSP
2
-
-
100 KVA DG Set along with associated accessories
1
-
-
1.1 kv Copper Control Cable Armoured for 220kv bays of size 2Cx6mm2, 7Cx4mm2, 4Cx4mm2, 2Cx4mm2, 16Cx2.5mm2, 10Cx2.5mm2, & 7Cx2.5mm2, 3Cx2.5mm2, including junction box etc.(as per Section-5 of copper control cables specifications & section-7 for switchyard erection)
1
-
-
1.1 kV Copper Control Cable unarmoured for 33 kV bays of size 2CX6mm2, 7CX4mm2, 4CX4mm2, 2CX4mm2, 16CX2.5mm2, 10CX2.5mm2, 7CX2.5mm2, 3CX2.5mm2 including Junction box (as per section-5 of copper control cables specifications and Section-7, switchyard erection).
1
-
-
650/1100 Volts 3.5 core 240 mm2 aluminium power cable from Aux. Transformer to ACDB
1
-
-
650/1100 Volts 3.5 core 70 mm2 aluminium cable for oil filtration set.
1
-
-
650/1100 Volts 4core 16mm2 armoured copper power cable for MLDB and other cable required as per contract for 220kv bays.
1
-
-
650/1100 Volt 4 core 16 mm2 unarmoured copper power cable for MLDB and other cable required as per contract for 33kV bays.
1
-
-
Earthing Mat Material. The earth mat will be designed / quoted for soil resistivity of 50Ὡm. In case soil resistivity is more than 50Ὡm then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item. (43470 sq. meter approx.)
1
-
-
Fire Fighting equipments as per section -6
a) 22.5 kg Capacity FE CO2 type, Trolley Mounted
4
-
-
b) 25 kg Capacity FE DCP type, Trolley Mounted
4
-
-
c) DCP 9 kg Capacity, wall mounted
9
-
-
d) FE CO2 6.5 Kg Capacity, Wall mounted
7
-
-
e) DCP 6 kg Capacity, wall mounted
2
-
-
f) Foam type 9 Litre Capacity, Wall mounted
1
-
-
g) Water CO2 9 Litre, Wall mounted
1
-
-
h) Fire buckets (12 Nos. with stand in one set)
2
-
-
Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area including all accessories, cables etc. as per clause 16.0 of section 7 of the specifications.
48
-
-
Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets including all accessories, cables etc. as per clause 16.0 of section -7 of the specification.
20
-
-
a) Supply and installation of 35W LED tube fitting on tubular steel poles along fencing/boundary wall at a distance of 30 meter including all accessories, cables etc.as per clause 16.0 of section 7 of the specification.
30
-
-
b) Supply and installation of Post top lantern 40W LED Lamps with all complete accessories at the enterance gate of substation.
4
-
-
c) Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building
4
-
-
High wall type split AC unit of 2 Ton capacity for computer room (as per technical specifications)
2
-
-
Testing of IUM System at NABL accredited lab
1
-
-
complete Substation automation system for 220/33KV substations including hardware (along with transducers) & software for present bays and software for future bay alongiwth associated equipment for the bays as defined in the technical specification, sec-sub-station automation system) as per technical specification.The scope for present and future is as under:-
220kV System Present Bays Future Bays
Line Bays 4 2
Transformer Bay 2 2
Bus Coupler Bay 1 -
33kV System
Line Bays 10 10
Transformer Incomer Bay 2 2
Bus Coupler Bay 1 1
Capacitor Bay 2 2
1
-
-
Computer system (SFF) with Intel Core i5, 9th generation processor, 8GB RAM, 1 TB HDD, 19.5 Display with UPS.
1
-
-
Mono chrome Multi-functional Printer,A-4,25 PPM,Wi-Fi
1
-
-
Bolted type 220kv Single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connection and tension clamp set suitable for twin Trantulla (string).
42
-
-
Bolted type 220kv Single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connection suitable for twin Trantulla (string).
15
-
-
Bolted type 220kv Single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connection and tension clamp sets suitable for Single Trantulla (string).
36
-
-
Bolted type 220kv Single Suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connections and suspension clamp sets suitable for single Trantulla conductor.
36
-
-
Bolted type 33 kV single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connection and tension clamp set suitable for twin Tarantula (string).
60
-
-
Bolted type 33 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connection suitable for twin Tarantula (string).
24
-
-
Bolted type 33 kV Single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connections and tension clamp sets suitable for single Tarantula (string).
78
-
-
Boltless C-Type Wedge connectors matching with conductor size.
1
-
-
Copper lugs glands, PVC ferrules for control cabling.
1
-
-
Fibre cleats, Aluminium clamps, bolts, nuts, washers etc., for fixing control cables in trenches
1
-
-
Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 150x25x2mm, 100x25x2mm and 75x25x2mm and G.I. Conduits of 50mm/100mm diameter from euipment to main trench as per section-7, Switchyard erection.
1
-
-
2.5" dia HDD/PVC for 4Cx4mm2 control cable from CT, VT to metering system as per Section-5, Chapter-5
1
-
-
AAC Trantulla conductor
6800
-
-
7/3.15 Earth Wire
500
-
-
Spacers for Twin Tarantulla Conductor
1
-
-
U-Bolt 20mm dia
1
-
-
Item for associated structure work
‘Lattice type steel structure for 220 kV Substations Chickenwas. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 220/132/33 kV switchyard fabricated from steel conforming to IS: 2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner.
A. Main Substation Tower and beam
a) Tower type AT-1
7
-
-
b) Tower type AT-3
8
-
-
c) Tower type AT-4
4
-
-
d) Tower type AT-6
8
-
-
e) Beam type AB-1
16
-
-
f) Beam type AB-2
8
-
-
g) Tower type CT-4
14
-
-
h) Tower type CT-5
18
-
-
i) Tower type CT-6
5
-
-
j) Tower type CT-8
10
-
-
k) Beam type DD-1*
31
-
-
l) Beam type DD-2*
10
-
-
B. Equipment Structure
1. 220kv CT Drawing. No. HTD/ST-147
21
-
-
2. 220kv NCT Drawing. No. HTD/ST-150
2
-
-
3. 220kv PT/CVT Drawing. No. HTD/ST-147
10
-
-
4. 220kv Surger Arrestor Drawing. No. HTD/ST-93R
18
-
-
5. 220kv Bus Post Insulater Drawing. No. HTD/ST-116
14
-
-
6. 220kv Isolater/L&E Drawing. No. HTD/ST-170
18
-
-
7. 33 kV Surge Arrestor Drawing No. HTD/ST-89R
42
-
-
8. 33 kV CT drawing No. HTD/ST-88
45
-
-
9. 33 kV Isolator/L&E drawing HTD/ST-110
46
-
-
10. 33 kV NCT drawing HTD/ST-88
2
-
-
11. 33 kV PT drawing HTD/ST-88
6
-
-
BOQ OF PLCC EQUIPMENTS
LILO of both ckts of 220kV PGCIL Hisar- Fatehbad at 220kV Chickenwas
a) PLC terminals
2 (1 No. for 220kV S/Stn Chickenwas & 1 No. for PGCIL Hisar/Fatehbad)
2
-
-
b) PLC terminals with protection coupler
4 (2 No. for 220kV S/Stn Chickenwas & 2 No. for PGCIL Hisar/Fatehbad)
4
-
-
c) Wave trap (2000A)
4 No. for 220kV S/Stn Chickenwas (To be supplied by HVPNL from Carrier Store, Sewah store)
4
-
-
d) LTU
4 (2 No. for 220kV S/Stn Chickenwas & 2 No. for PGCIL Hisar/Fatehbad)
4
-
-
e) 48V Battery & battery charger 300AH
(1 for 220kV S/Stn Chickenwas)
1
-
-
f) HF cable
1
-
-
1. EARTH WORK IN FILLING
1.1 Earth filling with good earth (as per satisfaction of Executive Engineer/Civil Works Division), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect.
72000
-
-
2. FOUNDATIONS
Supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & drawings attached with the tender document including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc. and other items not mentioned herein but required for the completion of work.
A. GANTRY TOWERS i) AT-1
7
-
-
ii) AT-3
8
-
-
iii) AT-4
4
-
-
iv) AT-6
8
-
-
v) CT-4
14
-
-
vi) CT-5
18
-
-
vii) CT-6
5
-
-
viii) CT-8
10
-
-
B. EQUIPMENT 220kV side
i) 220kV LA
18
-
-
ii) 220kV Isolator/L&E switch
18
-
-
iii) 220kV CVT
4
-
-
iv) 220kV PT
6
-
-
v) 220kV CT
21
-
-
vi) 220kV Post Insulator
14
-
-
vii) 220kV NCT
2
-
-
33 kV side
i) 33kV LA
42
-
-
ii) 33kV Isolator/L&E switch
46
-
-
iii) 33 kV NCT
2
-
-
iv) 33 kV CT
45
-
-
v) 33 kV PT
6
-
-
3. BREAKER FOUNDATION
Design, Engineering, Supply of labour, material and Construction of breaker foundations including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications. i) 220kV SF-6 Breaker
7
-
-
ii) 33kV VCB
15
-
-
4. ROADS
Supply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification. i. 6.0M approach road upto main gate
15
-
-
ii.5.0m wide road within substation land
230
-
-
iii. 3.66m wide road within substation land
65
-
-
5. CAPACITOR BANK FOUNDATIONS
Design, Engg. & supply of labour, material & construction of foundations for following rating capacitor bank with capacitor unit (with allied equipments) & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification.
i) 1x21.744 MVAR 33 kV capacitor bank
2
-
-
6. ROAD CULVERT
Design, Engineering and const. of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards.
1
-
-
7. TRANSFORMER FOUNDATION
7.1 Construction of transformer foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & drawing attached. In case extra foundation(s) has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this account.
i) 100MVA,220/33kV T/F foundation
2
-
-
7.2 Design, Engg., supply of labour, T&P and material including RCC, PCC, Reinforcement steel, misc. structural steel & other item(s) not mentioned herein but required for the completion of work as per tech. specs. for construction of below mentioned T/F foundations. i) 200KVA 33/0.4kv Station T/F
2
-
-
ii) 100kVA DG Set
1
-
-
8. OUTDOOR CABLE TRENCHES
Supply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts crossings for roads and sumpit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per approved Trench layout plan, HVPNL drgs. & tech. specs. complete in all respect.
1
-
-
9. SITE SURFACING
9.1 Providing, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of XEN/Civil Works Division.
1400
-
-
9.2 Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed/ crushed/broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed /broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of concerned XEN/Civil Works Division.
10100
-
-
10. BOUNDARY WALL
10.1 Supply of labour, T&P, material & construction of front, side & U/C boundary walls (brickwork below DPC level) as per GELO/CLO, tech. spec. & HVPNL drgs including excavation, PCC, back filling etc. complete in all respects.
1450
-
-
10.2 Supply of labour, material and construction of front, C & U/C boundary walls above DPC including main gate foundations as per GELO/CLO, technical specifications. & HVPNL drg. HCD/TS-1176 R3 including DPC complete in all respect.
i. 6 ft. high U/C B/wall with barbed wire on angles at top including construction of entrance gate(w/o wicket gate) for yard.
740
-
-
ii. 4½ ft. high front wall including providing grill at top of wall & construction of main entrance gate (with wicket gate).
120
-
-
iii. 4½ ft. high side wall with barbed wire on angles at top of wall.
30
-
-
11. CONTROL ROOM
Supply of labour, material & construction of control room building complete in all respect as per tech. specs. & approved drgs. attached including exterior & interior acrylic emulsion paint, all internal services like water supply including supply & providing of 5000ltr. capacity triple layered Sintex/Diplast PVC tank, sewerage system, staircase, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans , finishing, plinth protection, indoor trenches, trench covers, soakage pit near the switch house building, connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority/ submersible bore (as applicable) etc. & any other item not mentioned herein but required for completion of works. The successful bidder shall also provide water supply connection from bore well/HUDA/Municipal /Public Health or Panchyat water supply scheme (as per available source of portable water) to the control room bldgs. without any extra cost of HVPNL.
4917
-
-
12. U/C FENCING & GATES Providing & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached.
105
-
-
13. PCC PAVEMENT
Construction of PCC pavement in front, rear or side (as per site requirement of the switch house building) as per drawing no. HCD/SK-172 & technical specifications.
250
-
-
14. DRAINAGE-CUM-RAIN HARVESTING SYSTEM
14.1 Supply of labour, material for construction of recharge structures with bore well(s) as per HVPN drawings & specs. complete in all respect. The location of recharge structures shall preferably be located on corner(s) of the substation and shall be got decided from the concerned XEN/Civil Works Division on the basis of surroundings of the substation(s). In case ground water table is less than 8m from FGL, rain harvesting well shall not be constructed (the drainage system with sump pit is to be constructed as per item mentioned below).
2
-
-
14.2 The successful bidder shall evolve design & drawing for drains, manholes with RCC covers and settlement tank including preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be located on corner(s) of the s/stn. and shall be got decided from the concerned XEN/Civil Works Division on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide two no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.
1
-
-
15. AC Kiosk (Framed Structure)
Design, Engineering including architectural and structural drawings of AC Kiosk building (framed structure) ,supply of labour, material and construction of GIS building comprising of Anti-Termite treatment, plinth protection, electrification (Ceiling LED tubes with fitting, modular switches, boxes, AC, electric wire etc.), acrylic emulsion and weather proof (exterior acrylic paint), aluminum work (doors/windows/ventilators frames etc), false ceiling, floor finishing,indoor RCC cable trenches,double wall with 50mm thick glass/mineral wool insulation complete in all respect as per technical specification. Items, which are not mentioned but required for completion of work shall be provided by the successful bidder without any extra cost.
i) 220 kv Ac kiosk
4
-
-
ii) 33 kv Ac Kiosk
4
-
-
16. RCC M-20 inclusive of labour, material, shuttering, Steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing natural ground level and the formation level to be fixed after contouring or difference on account of revised drawing issued at the time of construction and the tender drawing.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements