Haryana Urban Development Authority Tender
... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 2,660Document Cost
₹ 250Tender Fee
₹ 1,180
Summary
Pf Of Electrical Installations And Repair And Renovation Of House No.1252 At Twell No. M 19 In Sec 7 Panchkula With One Year Free Mtc. Defect Liability Period Free Of Cost
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_HBC_439613_1Bid Award Id
ViewTender No
2025DDC9E48A 956D 49CA B448 7AFF9D8921EE269HSVTender Authority
Haryana Urban Development Authority ViewPurchaser Address
-Website
http://https://www.hsvphry.org.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
23.3.6.9:- Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 3 run of Size 1.50 Sqmm(1/1.40mm)
90
189
17010
... More
23.3.6.10:- Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 3 run of Size 2.50 Sqmm(1.1.80mm)
90
271
24390
... More
23.3.6.3:- Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm)
50
144
7200
... More
23.8.10.4:- FITTING AND ACCESSORIES Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules
10
186
1860
... More
23.8.10.5:- Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 8 Modules
10
233
2330
... More
23.8.10.6:- Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 12 Modules
5
282
1410
... More
23.8.11.1:- Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch
6
41
246
... More
23.8.11.3:- Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch
15
82
1230
... More
23.8.11.4:- Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket
15
82
1230
... More
23.8.11.5:- Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket
15
124
1860
... More
23.7.6.2:- PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
60
32
1920
... More
23.8.11.7:- FITTING AND ACCESSORIES Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete
in all respect. step type Fan Regulator 2 modules 300 watt
10
257
2570
... More
23.8.11.12:- Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. USB Charger, 1000mA, 5V, 1 Module ( For Non residential use only)
10
304
3040
... More
23.22.4.8:- MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing)
1
5755
5755
... More
23.22.5.1:- Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
10
145
1450
... More
23.22.5.8:- Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE
1
1291
1291