If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Haryana Tourism Corporation Limited - HBC Tender

Works
Telecommunication Services
Eprocure
Opening Date24 Jan 2020
Closing Date19 Feb 2020
Tender Amount₹ 1,63,25,000 
Notes
Download

Costs

  • EMD

    ₹ 3,26,500
  • Document Cost

    ₹ 17,700
  • Tender Fee

    ₹ 1,180

Summary

Development Of Tourist Infrastructure At Places Related To Mahabharat In Kurukshetra Under Krishna Circuit

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
o There shall be 8 control inputs, which should be freely programmable.

-

-

-

... More
o The network controller shall have analog audio line outputs for fire alarm signals, music sources etc. The network controller shall have the capability to handle at least 100 levels of priorities and 200 zones, 30 call stations or MMI (Man Machine Interface)

-

-

-

... More
o The network controller shall monitor the status of all zones in the system and the last 200 status change and fault events should be logged.

-

-

-

... More
o Attention and alarm tone definitions shall be stored in the network controller or recalled from an external storage device through control ports. These tones can be accessed by any call stations or control inputs for announcement broadcast or alarm broadcast.

-

-

-

... More
o At least 4 pre-recorded messages should be played simultaneously.

-

-

-

... More
o The network control unit shall have extensive audio processing possibilities for audio inputs and audio outputs. Parametric equalisation, limiter, and gain can be adjusted with the configuration software.

-

-

-

... More
o The network controller shall monitor the status of all equipment including the status of the microphone capsule of a call station and report any fault.

-

-

-

... More
o The network controller should have hot standby auto switchover facility to redundant controller.

-

-

-

... More
o The controller should 16X2 front panel LCD display and rotary control, through which debugging of faults will be possible.

-

-

-

... More
o It shall be compliant to EN 60849, EN 54-16.

-

-

-

... More
Technical Specification: Power Source: 115/230 VAC ±10%, 50/60 Hz, Battery Power Supply: 48V DC, Power consumption: 14W with no load, 150W with maximum load, Audio inputs: 28 channels, Control Inputs: 8, Control Outputs: 8 Line Outputs: 4, Operating Temperature: -50C to +550C, Frequency response: 20 Hz to 20 kHz (-3 dB) Event Logs: 200 Make: Bosch/TOA/Audio Technica

-

-

-

... More
Supply, Installation, testing and commissioning of Audio over IP interface shall have a network interface for fiber optical hybrid cabling with dual network connections, capable of redundant loop operation. The Audio over IP interface shall also provide a network interface to an industry-standard Ethernet based Audio over IP with redundant CAT-5 network connections. The fiber optic network interface of the Audio over IP Interface shall support multi-channel digital audio and control signals. The Audio over IP interface shall transfer predefined digital audio channels from the Audio over IP network to dynamically assigned audio channels on the fiber optic network. Simultaneously, the Audio Over IP interface shall transfer dynamically assigned digital audio channels from the fiber optic network to predefined audio channels on the Audio Over IP network. The Audio over IP interface shall have a supervision system to monitor its operation conditions. Network connectivity status and fault conditions shall be displayed on a back-lit LCD on the front panel. In normal operation conditions this LCD will show a configurable name for the Audio Over IP interface to allow for easy identification and a level indicator bar for each input and output. Fault conditions shall also be reported by the unit to a network connected system controller for logging purposes. The control inputs shall have configurable functionality, such as automatically starting an emergency alarm in case of activation by a fire detector or control of background music volume. The Audio over IP interface cabinet shall be 19”-wide and 2U-high for easy rack mounting without the need for free rack space between units Make: Bosch/TOA/AudioTechnica

2

-

355000

... More
Supply, Installation, testing and commissioning of call station for announcing console is used for making a manual or pre-recorded call to any pre-assigned zones or executing a predefined action. The call station shall have a fixed microphone to transmit speech over the network and a press-to-talk key. Technical Specifications: External power supply: 18 to 56 VDC Power consumption 4.4 W (DC) excluding keypads Microphone: Nominal acoustic input level 75 to 90 dB S/N 60 dB at 85 dB Loudspeaker S/N 80 dB at max. OutputSound pressure level 85 dB at 0.5 m and 1 kHz. Make: Bosch/TOA/AudioTechnica

1

-

64000

... More
Supply, Installation, testing and commissioning of Remote call station is to be used for lost and found announcement purpose and other applications with following functionalities: Connects to call station interface via CAT-5 cable, Up to 1 km from digital public address optical network, Uses standard keypads for extension, Built-in limiter, Powered via CAT-5 and/or local power supply and complete supervision. Technical Specifications: Electrical: External power supply 18 to 56 VDC, Power consumption 2.9 W at 48 V without keypads, Microphone: Nominal acoustic input level 75 to 90 dB SPL, S/N 60 dB at 85 dB SPL, Frequency response: 340 Hz to 14 kHz (-3 dB) Loudspeaker S/N: 80 dB at max. Sound pressure level: 85 dB (SPL) at 0.5 m and 1 kHz Headset Connector 3.5 mm jack. Make: Bosch/TOA/AudioTechnica

1

-

69000

... More
Supply, Installation, testing and commissioning of Call Station keypad with 8 or more programmable keys with activation indicators complete in all respect as per satisfaction of engineer in charge. Make: Bosch/TOA/AudioTechnica

2

-

30000

... More
Supply, Installation, testing and commissioning of Power Amplifier. The main function of the power amplifier is the amplification of audio signals for the loudspeakers. It shall be possible to select the output voltage between 100V and 70V by changing jumpers. It should have at least the following functionalities:

28

-

272700

... More
o The amplifier should have DSP built in for Equalization, delay settings etc. The noise dependant Automatic Volume Control (AVC) circuitry should be built in. Each amplifier should have min two channels for AVC function.

-

-

-

... More
o The amplifier monitoring and changeover facility shall be incorporated with the power amplifier. The changeover relays shall be integrated with the standby unit. In case of failure of any working amplifier, the standby amplifier shall automatically come in the circuit.

-

-

-

... More
o The amplifier should have rotary or push control for selection of system enquiry mode and Headphone volume along with LCD display.

-

-

-

... More
o The amplifier should have the built-in line and loud speaker supervision, automatic volume control, automatic ventilation temperature control, auto change over to DC power supply.

-

-

-

... More
o Channels as required.

-

-

-

... More
Power amplifier technical specifications are as follows: Mains supply: 115/ 230VAC 10% at 50 - 60 Hz, Type of Amplifiers Class D, Indication & Controls: 2 x 16-character LCD display for status display, Rotary/push control for selection of system enquiry mode .Output Power: 1 x 500W. Outputs Selectable 100V, 70V. Audio Input: Mono,balanced, Control Inputs 8 Control Outputs 1 or 2 or 4 or 8 depending on the amplifier type. Frequency response 60 Hz to 20 kHz (-3 dB). Frequency Response (audio inputs) Line: -3dB at 20Hz and 20KHz Mic: -3dB at 100Hz to 16KHz, Total harmonic distortion 0.3% (1 kHz) at 50% of rated power Cross talk: 70 dB (1 kHz) nominal (only multichannel). Signal to noise ratio: 85 dB with pilot tone off, Battery Power Supply: 48V, Safety and Emergency: According to EN 60849 and EN 54-16 . Make: Bosch/TOA/AudioTechnica

-

-

-

... More
Supply, Installation, testing and commissioning of PC Call Server, it provides facilities for connected clients, such as identification, making of calls, BGM source and volume control, acknowledge and reset of emergency modes, time synchronization, Multiple views of a system can be configured as background images with zone and zone group locations, allows control of BGM source and volume in the configured zones and gives feedback about the actual volume. It sed for making live speech or pre-record announcements to any zone or a group of zones or to execute any pre-defined actions. On-screen configuration sections allow the user to enter the properties of any combination of zones or individual zone such as entering the name of a zone/group, pre-defined input/output relay actions and selected attention/alarm tones or pre-recorded messages. Make: Bosch/TOA/AudioTechnica

1

-

146000

... More
Supply, Installation, testing and commissioning of Horn loudspeaker with aluminium body, with steel mounting bracket. Maximum power 75 W Rated power 50 W, Sound pressure level at 1 W (1 kHz, 1 m) 109 dBor more (SPL), Max SPL: 125dB or more, Effective frequency range (-10 dB) 350 Hz to 4 kHz, Water-and dust protected to IP 65 rating. Safety and Emergency according to EN 60065 and EN 60849. Make: Bosch/TOA/AudioTechnica

262

-

10800

... More
Supply, Installation, testing and commissioning of Bracket for mounting of speakers complete in all respect as per satisfaction of engineer in charge. Make: Custom

262

-

1035

... More
Supply, Installation, testing and commissioning of PC Client Intel i5 processor (for workstation) with clock speed- minimum 3.0GHz, RAM 8 GB & Expandable. Window 7/10 or Window 2008 Server or Unix based Edition .21” LED color monitors. Minimum 1TB (For Workstations)With Read & Write functions . LAN Interface 10/100Mbps Ethernet. PCI express graphics card Mouse Optical . USB port at front Dual and dual monitor support. Make: HP, Dell, IBM.

1

-

69400

... More
Supply, Installation, testing and commissioning of Network cable assembly 2 m of dia 7mm in black colour pull force 150N (Max) complete in all respect as per satisfaction of engineer in charge. Make: Bosch/TOA/AudioTechnica

37

-

5200

... More
Supply, Installation, testing and commissioning of Network cable assembly 10 m of dia 7mm in black colour pull force 150N (Max) complete in all respect as per satisfaction of engineer in charge. Make: Bosch/TOA/AudioTechnica

4

-

11900

... More
Supply, Installation, testing and commissioning of Armoured speaker cable 2 core 1.5 Sqmm complete in all respect as per satisfaction of engineer in charge. Make: Polycab/Havells/RRKabel.

4500

-

106

... More
Supply, Installation, testing and commissioning for 36U indoor rack with 800X800 high density rack with framework with 2 Horizontal and 2 Vertical channel with 4 FAN tray roof cabinet. 1 Top Cover and 1 Bottom Cover with gland plate and rubber grommets for cable entry provisions, 4 Recess mounting angles, with PVC cable separation cable manager. Rack should be certified complete in all respect as per satisfaction of engineer in charge. Make: Valrack,Netrack,Netlink

4

-

47600

... More
Supply, Installation, testing and commissioning of HDPE pipe 32mm. Complete in all respect as per satisfaction of engineer in charge.

3500

-

40



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.