Haryana Rural Roads And Infrastructure Development Agency Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
Refer DocumentsDocument Cost
₹ 15,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_HRRDA_107854_1Bid Award Id
ViewTender No
HR09-III-04Tender Authority
Haryana Rural Roads And Infrastructure Development Agency ViewPurchaser Address
-Website
http://http://hsrdc.org.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Earth work excavation in ordinary soil exclusive of compensation of earth-earth-work undressed with all lead & lift including breaking of clods. (HSR 6.2b) , and relaying the same for making of berms and side slopes including laying , dressing, watering & rolling as per HSR 6.2 g-i, g iii & g-v -
2081.19
-
-
... More
Preparation of sub-grade including trenching rough dressing of soil, final dressing of earth to given levels and chamber , watering, rolling with road roller and compacting the bed in all respect before laying paving material [confirming to clause 301 of MoRD specification for Rural Roads-2004] Note: - In widening portion sub grade will be prepared with the use of Baby roller (HSR 24.1) or width of excavation should be made sufficient wide to accommodate road roller. Extra width required for compaction of sub grade shall not be paid and its expenditure shall be in incidental to the work.
17815.86
-
-
... More
Preparation of berms including filling of Earth work, excavation and cutting of earth in all kind of soils including dressing the bank, side slope to given levels and templates after breaking of clouds, including the cost of rolling and watering all allowances for labour hardness wetness irrespective of all lead and lift and including Compensation for earth taken from private land, fields etc. and compacted to meet requirement of table 300-2 of MoRT&H specification clause No. 30 and to entire satisfaction of the Engineer of the work confirming to PWD specification No. 6.2 and 6.3 and 3.2 and the other specification 1990 Ist edition. As per X-section. This item also includes E/W if required in sub grade for Widening and Shoulder. Earth used for sub grade, shoulder and berms should have minimum CBR 8%. Note:- No earth work will be allowed to be taken from PWD B&R/ROW except for surplus earth after approval from Engineer.
8.1
-
-
... More
Providing laying, watering and compacting of 150 mm thick granular sub base (G-I) consisting of filter layer confirming to Table 400.1 Grading - 1 of MoRD specifications, mixing in a mechanical mix plant at OMC, carriage of mix material to the site of work, spreading in uniform layer with motor grader on prepared surface and compacting with vibratory power roller to achieve desired density complete as per clause No. 401 of MoRD specifications 2004.
Note - 1. Only crushed metal material should be used. No local earth sand shall be used. The material finer than 425 micron shall have zero Plasticity Index (PI).
417.3
-
-
... More
Stabilized Sub Base (In widening Portion): Providing, Laying, Spreading and Compacting in-situ/borrow area soil of CBR 5% mixed with 30% crushed aggregate / GSB Grade 2 as per mix design. Application: (1) Spread soil 70% in required area with excavator. Spread aggregates 30% as per mix design in soil. Mix with tractor operated rotavator to achieve uniform mix and desired thickness. (2) Spread Cement 3% by weight of soil & aggregate mix. Loosen with tractor operated ripper and mix thoroughly with tractor operated rotavator. (3) Apply 0.60 kg/cum Organosilane Nanotechnology and 0.60 kg/cum Nano Acrylic Co-polymer mixed in OMC water (1000 ppm TDS) on loose soil-aggregate-cement mixes. Scarify & mix the treated material with rotavator and grade it with grader and do light compaction with vibratory compactor. (4) Compact the stabilized soil-cement-aggregate base with 8 to 10 tonne vibratory roller to achieve the desired density.
Rates include all material, labour, hire charges of machinery etc. as per MoRD specifications & direction of Engineer-in-Charge in consultation with concerned technology provider as approved by department.
1503.39
-
-
... More
Stabilized Base: Providing, Laying, Spreading and Compacting in-situ/borrow area soil of CBR 5% mixed with 30% crushed aggregate / GSB Grade 2 as per mix design. Application: (1) Spread soil 70% in required area with excavator. Spread aggregates 30% as per mix design in soil. Mix with tractor operated rotavator to achieve uniform mix and desired thickness. (2) Spread Cement 4% by weight of soil & aggregate mix. Loosen with tractor operated ripper and mix thoroughly with tractor operated rotavator. (3) Apply 1.0 kg/cum Organosilane Nanotechnology and 1.0 kg/cum Nano Acrylic Co-polymer mixed in OMC water (1000 ppm TDS) on loose soil-aggregate-cement mixes. Scarify & mix the treated material with rotavator and grade it with grader and do light compaction with vibratory compactor. (4) Compact the stabilized soil-cement-aggregate base with 8 to 10 tonne vibratory roller to achieve the desired density.
Rates include all material, labour, hire charges of machinery etc. as per MoRD specifications & direction of Engineer-in-Charge in consultation with concerned technology provider as approved by department.
3788.19
-
-
... More
Waterproofing on top compacted ( as per relevant MoRD specification) subgrade/shoulders/sub base/base, as specified, with Organosilane Nanotechnology & Nano Acrylic Co-polymer with water (1000 ppm TDS) in the ratio of 1 kg Organosilane Nanotechnology: 1 kg nano acrylic co-polymer : 200 liter water spray @ 3 liter/sqm in two spray applications (1.5 liter + 1.5 liter) as per direction of the Engineer-in-charge in consultation with concerned technology provider as approved by department.
37881.86
-
-
... More
Providing & laying 75/150 mm thick (Compacted) stone metal (G-III) 53mm to 22.4mm gauge wearing coat to water bound macadam in layer of 75 mm each using screening type ‘B’ compacting with three wheeled power rollers of 80-100 kN capacity or tandem or vibratory of 80-100 kN static weigth to achieve the desire density including lighting, guarding barricading and maintenance of diversion etc. as per clause no 405 of MoRD specification for Rural Roads-2004) as per drawing and design directed by the Engineer complete in all respects.(N.S.) Note: - 1.Only crushed stone metal material should be used. No local earth/ natural occurring sand shall be used. The material finer than 425 micron shall have zero Plasticity Index (PI). 2. Materials to be used and operations of manufacturing shall be approved by engineer.
3855.15
-
-
... More
Prime Coat: Preparing and applying of water soluble Organosilane Nanotechnology (for bitumen emulsion application, IRC approved) with cationic bitumen emulsion CSS1 and water (1000 ppm TDS) in the ratio of 1 kg Organosilane Nanotechnology : 100 kg cationic bitumen emulsion CSS1 : 200 liter water. Mixing & Spraying : Take 1 kg of Organosilane nanotechnology and add in 200 liter water while filling water in tanker/drum and then add 100 kg cationic bitumen emulsion under circulation. Mix the solution completely. Spray the solution @ 1 liter per sqm on compacted stone base. Rates including all materials, labour, hire Charges of machinery etc. complete as per MoRD specifications & direction of Engineer-in-Charge in consultation with concerned technology provider as approved by department.
37881.86
-
-
... More
Providing and applying tack coat with CSS-1 bitumen emulsion on prepared surface of Aggregate layer including clearing of road surface and spraying mixed with Organosilane Nanotechnology in the ratio of 1.4:100:200 (1.4 kg Organosilane:100 Kg SS1 Emulsion:200 ltrs Water); at the rate of 0.25 ltr/sqm using mechanical means as per the directions of Engineer-in-charge in consultation with concerned technology provider as approved by department.
37881.86
-
-
... More
Pdg& laying 50mm BM using the reclaimed material to the extent of 30% of the required quantity, hauling and stockpiling the reclaimed material near the central recycling plant after carrying out necessary checks and evaluation, adding fresh material including rejuvenators as required, mixing in Drum type hot mix plant, with appropriate arrangement for use of R.A.P., transporting and laying at site with hydraulic paver finisher with sensor control to the required grade and compacting to the required grade level and thickness with appropriate rollers all as specified in clause 519 (5th Revision) of 2013 using bitumen VG-30 dosed with 0.1% Organosilane Nanotechnology by weight of bitumen binder. (minimum Bitumen's 3.40% i/c bitumen of retrieved material as per job mix formula) complete in all respect. Note: -1. The milled material to be used in BM shall be minimum 80% of the theoretical quantity of milled material. 2. If bitumen required more than 3.40% as per job mix formula no extra payment will be paid extra bitumen required will be considered as incidental to work. 3. Before carrying out bituminous work, coating & Stripping of bitumen aggregate mix is to be performed in accordance with IS-6241. If coating and stripping of bitumen aggregate mix is less than 95%, anti-stripping agent will be used by contractor. The anti-stripping agent should conform to the requirement as stipulated in IS 14982:2017. The cost so incurred will be considered as incidental to work and noting extra shall be payable. The type and brand of anti-stripping agent along with procedure shall be approved by SE-in-Charge in writing before start of work. A proper record of results be maintained and same shall be submitted along with bills by the contractor.
1522.56
-
-
... More
Providing and Laying 50 mm thick Compacted bituminous macadam in (BM) in one layer by DRUM type hot mix plant and paver finisher with sensor control to the required grade level alignment and rolling with appropriate roller by as specified to achieved the desired density as per clause No. 504 table No. 500-4 of MoRD specification using minimum 3.4 % bitumen grade VG-30 as binder content by weight of total mix and dosed with 0.1% Organosilane Nanotechnology by weight of bitumen binder, complete in all respects i/c cost of bitumen, instruction issued from time to time by MoRD regarding machinery & bitumen will be followed strictly. The use of self propelled mechanical paver fitted with electronic sensor device conforming to MoRD specification in mandatory. If bitumen required is this account more than 3.4% as per job mix formula no extra payment will be made, extra bitumen required will be considered as incidental to work. Note: - 1. Before carrying out bituminous work, coating & Stripping of bitumen aggregate mix is to be performed in accordance with IS-6241. If coating and stripping of bitumen aggregate mix is less than 95%, anti-stripping agent will be used by contractor. The anti-stripping agent should conform to the requirement as stipulated in IS 14982:2017. The cost so incurred will be considered as incidental to work and noting extra shall be payable. The type and brand of anti-stripping agent along with procedure shall be approved by SE-in-Charge in writing before start of work. A proper record of results be maintained and same shall be submitted along with bills by the contractor.
371.53
-
-
... More
Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen dosed with 0.1% Organosilane Nanotechnology by weight of bitumen binder to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades in consultation with concerned technology provider as approved by department.
Note: - 1. Before carrying out bituminous work, coating & Stripping of bitumen aggregate mix is to be performed in accordance with IS-6241. If coating and stripping of bitumen aggregate mix is less than 95%, anti-stripping agent will be used by contractor. The anti-stripping agent should conform to the requirement as stipulated in IS 14982:2017. The cost so incurred will be considered as incidental to work and noting extra shall be payable. The type and brand of anti-stripping agent along with procedure shall be approved by SE-in-Charge in writing before start of work. A proper record of results be maintained and same shall be submitted along with bills by the contractor.
37881.86
-
-
... More
Providing and laying of premix sand seal coat dosed with 0.1% Organosilane Nanotechnology by weight of bitumen binder with HMP of appropriate capacity not less than 75 tonnes/ hours using crushed stone chipping 6.7 mm size and penetration bitumen of suitable grade.
37881.86
-
-
... More
Dismantling of existing CC block including transporting and stacking usable block along road side and dispose unusable blocks outside PWD land or desired by Engineer (NS)
164.7
-
-
... More
Relaying old CC blocks over 25 mm thick fine sand including transportation from road side where stacked excluding cost of CC blocks and complete in all respect as per specifications (NS).
131.76
-
-
... More
Manufacturing, laying of table vibrator cement concrete blocks of size 0.450mm X0.300mm X 0.150mm of cement concrete(C.C) M-30 grade and spreading 25mm thick sand under neath and filling joints with sand on existing base as per Technical specification Clause 1503 of MoRD specification for Rural roads 2004.
999.24
-
-
... More
Providing & Marking center line / side line 2.5mm thick (minimum) with hot applied thermo-plastic road marking paint 10cms wide complete in all respect such as furnishing all labour, materials, tolls equipments including all incidental costs necessary for carrying out in work at site confirming to the technical specification as clause No. 1702 of MoRD specification . Each container of the thermoplastic material shall have the name trademark or other means of identification of manufacturer, batch number, date of manufacture color maximum application temperature and maximum heating temperature. The thermoplastic paint material shall be of Asian Paint-Apcomark/Berger-Sigmarc/Prismo. The glass beads shall be of Potters/Sovitec/Fleolite. The thermoplastic material shall be sampled and tested in accordance with appropriate ASTM/BS method. The contractor shall furnish to the Engineer-in-Charge a copy of certified test reports from the manufacturer of the thermoplastic material meet all requirement of the specifications. The reflectorzing glass beads shall meet the requirement of clause 803.4.2 and test methods mentioned in clause 803.4.2.4 shall be meticulously followed. The minimum thickness specified is exclusive of surface of glass beads .the method of thickness measurement shall be in accordance with appendix B and C of BS:3262 (part-3).
Note:- Before start of work the contractor shall give brand , batch no. , manufacturing date of the material to be used and get approved the same from Engineer-In-Charge before use.
544
-
-
... More
Providing lowering, cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 which Spigot & socketted joints manufactured with ISI marked antiternmite as required at site, into trenches, for all depths and laying out the same to correct alignment, gridients and levels including dressing and trimming and cutting of concrete beds and sides of trenches, if required, jointing with rubber rings in trenching and jointing with 1 : 11/2 cement sand mortar and with end dowels filled with 1 : 11/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in HSR item no. 29.38, 29.44, 29.45 & 29.46 including cartage loading and unloading complete in all respects. (HSR 29.96)
58.5
-
-
... More
Providing Reinforced cement concrete M-15 grade 5th km stone of standard design as per IRC-8 fixing in position including painting and printing etc as per drawing and technical specification clause 1703 of MoRD specification clause for rural roads-2004.
1
-
-
... More
Providing kilometer stone made of concrete as per specified design conforming to MoRD specification No. 1703, all inclusive, including cost of concrete, fixing, painting writing etc. ( conforming to MoRD specifications for Rural Roads-2004).
7
-
-
... More
Providing and fixing 200 m stone made of concrete as per specified design conforming to MoRD specification no. 1703; all inclusive, including cost of concrete, fixing, painting, writing etc. ( conforming to MoRD specifications for Rural Roads-2004).
35
-
-
... More
Providingand fixing retroeflective hazard marker confirming to IRC 79:1981 of size 900x300 mm with back support of M S angle 25*5x3 mm and leg postof80mm dia having 1.6mm thickness dulypainted,1500 mm high embedded into 0.3x0.3x0.45m M20 gradeConcreteaspersite requirements, micro- usingnon-metallic prismaticretro-reflectivesheet confirming to IRC: 6720'12 type lY specificationfixed on 3 mm thick aluminum composite Material sheete as base having 0.5 mm thick aluminumon both sides.
22
-
-
... More
Providing and fixing of shoulder mounted sign boards of various sizes using non-metallic micro prismatic retroreflective sheet conforming to IRC: 67 -2012 type lV HIP specification fixed on 3 mm thick Aluminium anel,having 0.5 mm thick Composite Aluminium on both sides supported on Mild Steel Pipe leg post 80mmNB,1.6mm thick duly painted in alternative color of black and white embeded M-20 Grade concrete foundation of size 450mm x 450mm x 600mm, complete as per drawings, Technical Specifications and as directed by Engineer-in-Charge.
900 mm EQUILATERAL TRIANGLE
38
-
-
... More
900 mm HIGH OCTAGON
34
-
-
... More
Providing and fixing steel plate/ steel tube citizen informatory sign boards as prescribed by NRRDA (with two information plates of 750mm x 980mm size each) & other specifications conforming to the MoRD specification 2004; all inclusive, including excavation, concrete etc. Will supply warranty for sheeting Clause 801.3.11 .
2
-
-
... More
Providing and fixing of typical PMGSY informatory sign board with logo as per MoRD specification and drawing.Three MS plates of 1.6mm thick, top and middle plate duly welded with S flat iron 25mmX5mm size on back on edges,25mmX25mmX5mm. The angle iron frame of the lower most plate and flat iron frme of middle plate will be welded to 2 nos,.75mmX75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mmX450mmX600mm below ground level. The top most diamond plate will be welded to middle plate by 47mmX47mm of 12 SWG steel plate tube . All MS will be stove enamelded on both sides. Lettering and printing arrows, border etc. will painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.0.
3
-
-
... More
Providing and fixing Logo Board of PMGSY size 600×600mm diamond shape with 1 plate of size 900×250 mm made of 60 gauge sheet over frame of angle iron 25×5×3 as per PMGSY specifications & drawing, painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
2
-
-
... More
Providing & erecting OVERHEAD SIGNS gantry supported by M. S. Pipe Structure complete as per drawings, Technical Specifications and as directed by Engineer-In-Charge including construction of R.C. C. foundation for providing of M. S Tubular structure for Cantilever signage at given site as per drawing enclosed. The C. C. mix to be in ratio of 1:1½:3 (RCC 1:1½:3) and that of lean to be ratio of 1:3:6 the work will be carried out as per the instructions of Engineer-In-Charge. Note: Foundation including reinforcement etc. as per Drawing. Cantilever Over head Sign gantry. frame/truss Size- 3.05 m x 1.525 m
2
-
-
... More
Providing and fixing sign boards on the gantry as provided in the item No. 28 above, of size 3.05m x 1.525m made out of retro-reflective sheeting of high intensity micro prismatic grade confirming to IRC:67 – 2012 Type IV standard fixed on 4mm thick Aluminum Composite Panels (ACP sheet) as base board with pressure-sensitive adhesive numerals etc.) and borders of Retro Reflective Boards with pressure-sensitive adhesive having 0.5 mm thick Aluminum on both sides. The message (legends, letters, numerals etc.) and borders of Retro Reflective Boards shall be of cut letters made in transparent overlay film pasted over the base sheeting with pressure sensitive adhesive or as instructed by the manufacturers or as directed by the Engineer-in-Charge. Note:- 1.) Work will be carried out as per MoRTH specification for road and bridges works (5th revision). 2.) Retro-reflective sheeting of high intensity micro-prismatic grade confirming to IRC 67-2017 Type-IV Standard shall be of Avery Dennision/3M make only. 3.) Warranty and Durability as per clause 801.3.11 of MoRTH Specification 5th Revision will be applicable which is reproduced as under:- The contractor shall obtain from the manufacturer a ten year warranty for satisfactory field performance including stipulated retro-reflectance of the retro-reflective sheeting of micro-prismatic sheeting and a seven-year warranty for high intensity grade and submit the same to the Engineer. The warrenty shall be inclusive of the screen printed or cut out letters/legends and their bonding to the retro-reflective sheeting. The contractor/supplier shall also furnish the LOT numbers and certification that the signs and materials supplied against the assigned work meets all the stipulated requirements and carry the stipulated warranty and that the contractor / supplier is the authorized convertor of the particular sheeting. All signs shall be dated during fabrication with indelible markings to indicate the start of warranty. The warranty shall also cover the replacement obligation by the sheeting manufacturer as well as contractor for replacement/repair/restoration of the retro-reflective efficiency. A certificate in original shall be given by the sheeting manufacturer that its offered retro-reflective sheeting has been tested for various parameters such as co-efficient of retro-reflection, day/night time colour and luminance, shrinkage, flexibility, linear removal, adhesion, impact resistance, specular gloss and fungus resistance; the tests shall be carried out by a Government Laboratory in accordance with various ASTM procedures and the results must show that the sheeting has passes the requirements for all the above mentioned
parameters. A copy of the test reports shall be attached with the certificate.
9.3
-
-
... More
Pavement marker (Cat eyes)Molded shank raised pavement marker made polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a lad of 16000 Kg tested in accordance to ASTM D 4280 Type H. The height, width and length shall not exceed 50mm and 100mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall 35+/-5 degree.The strength of detachment of the intrgratedcyclindrical shanks(of diameter not less than 19+/-2mm and height no less than 30+/-2mm) from the body is to be a minimum value of 500 kg .Fixing will be bt drilling without nails and using epoxy resin based adhesive as per manufacturer’s recommendation(of reputed make such as 3M etc.)
450
-
-
... More
Cement Concrete 1:4:8 with stone aggregate 40mm nominal size in foundation and plinth (HSR 10.39)
252
-
-
... More
Cement Concrete 1:2:4 with stone aggregate 20mm nominal size in foundation and plinth. (HSR 10.41)
70
-
-
... More
Cement Concrete 1 : 1.5 : 3 with stone aggregate 20 mm nominal size for RCC work in slab with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement but including centering and shuttering, laid in position complete in all respect. (HSR 10.82 +10.95 (a)
74.2
-
-
... More
Providing & laying in position machine batached and machine mixed design mix M-15 grade cement concrete for reinforced cement concrete work, using cement content as er approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement, including admixtures in ommended proportions as per IS: 9103 to accelerate, retared setting of concrete, mprove workability without impairing strength and durability as per direction of Engineer-in charge in foundation and plinth. (Note: Cement Concrete considered in this item is @ 240 Kg/cum).(HSR 10.64)
57.87
-
-
... More
Providing & laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in- charge in foundation and plinth. (Note: Cement Concrete considered in this item is @ 300 kg/Cum.) (HSR 10.65)
63.17
-
-
... More
Providing & Laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge in foundation and plingth. (Note: Cement content considered in this item is @330 Kg/cum) (HSR 10.66)
29.87
-
-
... More
Brick Masonry Work in Cement Mortar 1:4 in Foundation complete excluding Pointing and Plastering, as per Drawing and Technical Specifications clause no. 1202 & 1203 of MoRD specification 2004
380
-
-
... More
12 mm thick Plastering with cement mortar (1:3) on brick work in sub-structure as per Technical Specifications (HSR 15.4)
1037.98
-
-
... More
Fe-500 E.Q.R. TMT Steel bars for R.C.C. works, where not included in the complete rate of R.C.C. including bending, binding and placing in position complete. (HSR 18.22) NOTE-Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, exckuding overlaps. from the length so measured, the weigth of reinforcement shall be calculated in tones on the basis of IS:1732. Wastage, overlaps, couplings,weleded joints,spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
12.78
-
-
... More
Ruled POINTING in 1 cement : 2 sand mortar on BRICK WALLS [conforming to MoRD specification for Rural Road - 2004]
30.75
-
-
... More
Providing BRICK ON EDGE FLOORING (nominal thickness 110mm), with SECOND class (100B/75A) bricks laid dry, inclding filling of joints with fine send[ conforming to MoRD specifications for Rural Roads-2004]
21.96
-
-
... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8
62.12
-
-
... More
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing and Technical Specifications clause No. 614, 709, 1204.3.7 of MoRD specification 2004 NOTE:- In case of any difference in the unit of nomenclature of any of the HSR/MORD Items depicted in this DNIT and that given HSR, the unit and nomenclature given in HSR shall be Applicable. NOTE- It may kindly be noted that the contractorwould be obligated to carry out 05 years paid maintenance as per the rates fixed in the DNIT. However, the items of 05 yearsmaintenance shall not be part of BOQ to avoid any confusion.
52
-
-