If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 5,00,000Document Cost
₹ 15,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_HRRDA_120413_1Bid Award Id
ViewTender No
HR9-III-301Tender Authority
Haryana Rural Roads And Infrastructure Development Agency ViewPurchaser Address
-Website
http://pmgsytenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications (HSR 17.5.3)
5144.31
-
-
... More
Preparation of berms including filling of Earth work, excavation and cutting of earth in all kind of soils including dressing the bank, side slope to given levels and templates after breaking of clouds, including the cost of rolling and watering all allowances for labour hardness wetness irrespective of all lead and lift and including Compensation for earth taken from private land, fields etc. and compacted to meet requirement of table 300-2 of MoRT&H specification clause No. 30 and to entire satisfaction of the Engineer of the work confirming to PWD specification No. 6.2 and 6.3 and 3.2 and the other specification 1990 Ist edition. As per X-section. This item also includes E/W if required in sub grade for Widening and Shoulder. Earth used for sub grade, shoulder and berms should have minimum CBR 8%. Note:- No earth work will be allowed to be taken from PWD B&R/ROW except for surplus earth after approval from Engineer.
10.1
-
-
... More
Providing and laying 150/200 mm thick granular sub base consisting of filter layer confirming to Table 400.1 Grading-I of MoRD specification, mixing in a mechanical mix plant at OMC, carriage of mix material to the site of work, spreading in uniform layer with motor grader on prepared suface and compacting with vibratory power roller to achieve desired density complete as per clause No. 401 of MoRD specification-2004. Note: - 1.Only crushed stone metal material should be used. No local earth sand shall be used. The material finer than 425 micron shall have zero Plasticity Index (PI). 2. Materials to be used and operations of manufacturing shall be approved by engineer.
1011.65
-
-
... More
Providing & laying 150/225 mm thick (Compacted) stone metal (G-III) 53mm to 22.4mm gauge wearing coat to water bound macadam in layer of 75mm each using screening type ‘B’ compacting with three wheeled power rollers of 80-100 kN capacity or tandem or vibratory of 80-100 kN static weigth to achieve the desire density including lighting, guarding barricading and maintenance of diversion etc. as per clause no 405 of MoRD specification for Rural Roads-2004) as per drawing and design directed by the Engineer complete in all respects.(N.S.) Note: - 1.Only crushed stone metal material should be used. No local earth/ natural occurring sand shall be used. The material finer than 425 micron shall have zero Plasticity Index (PI). 2. Materials to be used and operations of manufacturing shall be approved by engineer.
77.47
-
-
... More
Providing and applying primer coat with bitumen emulsion (SS-I) on prepared surface of granular base including cleaning of road surface and spraying primer mix including silane at the rate of 0.60 kg/sqm using mechanical means as per Technical specification clause 502 of MoRD specification Rural roads-2004. Instructions issued from time to time by MoRD regarding bitumen emulsion will be followed strictly.
344.31
-
-
... More
Providing and laying surface dressing as wearing course in First coat using crushed stone aggregates of 13 mm nominal size Pre-coated chipping with Bitumen @ of 1.00 % weight of Chips of specified size on a layer of bituminous binder VG - 10 @ 0.80 Kg per sqm laid on prepared surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 509 of MORT&H specifications.
Note:- 1. The aggregates are to be laid only using automatic Chip Spreader & no manual Laying is allowed.
2.The underlying Surface Course on which Surface Dressing is to be laid shall be prepared, Shaped and Conditioned to a uniform grade, Camber and section as specified. Any depressions or Pot-holes shall be properly made up and compacted sufficiently in advance. All pot-holes and depressions shall be filled up with a suitable premix material and rammed or rolled properly and brought to shape. Where the existing surface shows sign of fatting-up. Such portion should be rectified. This work be incidental to work.
56444.31
-
-
... More
Providing and laying surface dressing as wearing course in Second coat using crushed stone aggregates of 10 mm nominal size Pre-coated chipping with Bitumen @ of 1.00 % weight of Chips of specified size on a layer of bituminous binder VG - 10 @ 0.70 Kg per sqm laid on prepared surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 509 of MORT&H specifications.
Note:- 1. The aggregates are to be laid only using automatic Chip Spreading & no Manual Laying is allowed.
2. The second coat should not be applied until the first coat has been opened to traffic for 2 to 3 weeks.
56444.31
-
-
... More
Providing and Laying 80 mm thick ISI marked Interlocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect.(HSR 17.69.2)
4800
-
-
... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including Reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. Note:- Before start of work the contractor shall give brand , batch no. , manufacturing date of the material to be used and get approved thbe same from Engineer-In-Charge before use.(HSR 34.26)
777.7
-
-
... More
Providing and Laying 600 mm dia Reinforced cement concrete pipe NP3 prestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets 600 mm dia, as per clause 2900 of MORT&H specifications (HSR 17.61.1) Note:- Contractor shall supply bill of manufacture of pipes. Pipes should bear name of manufacturer and ISI mark along with bill duly valid ISI certificate of manufacturer should be supply. Without these bills certificate no payment shall be released.
48.75
-
-
... More
Providing & fixing Reinforced cement concrete M-25 grade precast 5th kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc complete as per technical clause 804 of MORTH Specifications (HSR.34.27.1)
2
-
-
... More
Providing & fixing Reinforced cement concrete M-25 grade precast ordinary kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc complete as per technical clause 804 of MORTH Specifications (HSR.34.27.2)
8
-
-
... More
Providing & fixing Reinforced cement concrete M-25 grade 200 meter stone of standard design as per IRC:8- 1980, fixing in position including painting and printing etc complete as per technical clause 804 of MORTH Specifications (HSR.34.27.4)
42
-
-
... More
Providing & fixing Hazard Marker sign board 300x900mm rectangular as per IRC 67- 2012 with using retro reflective Sheeting Class B as per ASTM D 4956 09 and IRC 67 2012, fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground including foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67- 2012. (HSR.34.19.2)
22
-
-
... More
Providing & fixing cautionary sign board as per IRC 67- 2012 with using retro reflective Sheeting Class B as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports including three year outdoor weathering test report for sheeting tested in India condition from an independent test laboratory conforming to clause 6.7 of IRC67-2012 900x900x900mm triangular (HSR.34.4.2)
45
-
-
... More
900 mm HIGH OCTAGON
35
-
-
... More
Providing and fixing steel plate/ steel tube citizen informatory sign boards as prescribed by NRRDA (with two information plates of 750mm x 980mm size each) & other specifications conforming to the MoRD specification 2004; all inclusive, including excavation, concrete etc. Will supply warranty for sheeting Clause 801.3.11
2
-
-
... More
Reinforced cement concrete M15 grade boundary pillar of standard design as per IRC:25-1967, fixed in position including finishing and lettering but excluding painting (HSR 34.28).
100
-
-
... More
Providing and fixing of typical PMGSY informatory sign board with logo as per MoRD specification and drawing.Three MS plates of 1.6mm thick, top and middle plate duly welded with S flat iron 25mmX5mm size on back on edges,25mmX25mmX5mm. The angle iron frame of the lower most plate and flat iron frme of middle plate will be welded to 2 nos,.75mmX75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mmX450mmX600mm below ground level. The top most diamond plate will be welded to middle plate by 47mmX47mm of 12 SWG steel plate tube . All MS will be stove enamelded on both sides. Lettering and printing arrows, border etc. will painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.0.
2
-
-
... More
Providing and fixing of typical PMGSY PMGSY Maintenance Board with logo as per MoRD specification and drawing.Three MS plates of 1.6mm thick, top and middle plate duly welded with S flat iron 25mmX5mm size on back on edges,25mmX25mmX5mm. The angle iron frame of the lower most plate and flat iron frme of middle plate will be welded to 2 nos,.75mmX75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mmX450mmX600mm below ground level. The top most diamond plate will be welded to middle plate by 47mmX47mm of 12 SWG steel plate tube . All MS will be stove enamelded on both sides. Lettering and printing arrows, border etc. will painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.0.
1
-
-
... More
Providing and fixing Logo Board of PMGSY size 600×600mm diamond shape with 1 plate of size 900×250 mm made of 60 gauge sheet over frame of angle iron 25×5×3 as per PMGSY specifications & drawing, painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
2
-
-
... More
Providing & fixing overhead sign board 3050x1525mm cantilever type single sided using retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67-2012 with retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012 fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 40x40x6mm angle iron supported on designed single support system of MS pipe and plates in the form of a cantilever type truss made with 350NB pipe @50kg per metre as vertical support, 50NB pipe @ 4.50kg per metre and 40NB pipe @ 3.61kg per metre for truss including base plates, gusset plates, designed RCC foundation for fixing in ground complete as per clause 802 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 .
2
-
-
... More
Providing and installation of solar cat eye produced from an engineered polymer selected for superior impact resistance and weather-ability. The top of the solar stud should be transparent for solar charging and light output in active mode. The base of the body shall be yellow or neutral white as approved by Engineer In-charge. The marker shall incorporate a solar panel (comprising of solar cells) for converting solar energy into electricity, a storage device for storing the energy, LEDs for illumination and a design for providing 360 degree smooth illumination. The Solar stud shall be round in shape for providing illumination in all directions. The solar stud shall also have high reflective polycarbonate/ methyl methecrylate lenses for conspicuity in passive mode and dual shanks for improved road presence. The solar studs are intended for application directly onto pavement surfaces and shall be applied with epoxy resin adhesives designed for use with raised pavement markers and as supplied by the marker manufacturer separately. The solar cat eye shall be of height: 65 ± 2 mm & Maximum Diameter: 136 ± 5 mm. The body of the solar cat eye shall be resistant to dust and water ingress as per IP 65 standards. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. (HSR 34.36)
350
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (HSR 6.1.6)
300
-
-
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - CC :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) (HSR 6.14.1)
88.8
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - CC 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)
84
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for - Suspended floors, roofs, landings, balconies and access platform (HSR 6.30.3)
672
-
-
... More
Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.M-15 grade plain cement concrete. (cement content considered @ 240 kg/cum) (HSR 6.22.2.2)
(Note :- Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix)
19.27
-
-
... More
Brick work with common burnt clay non modular bricks of class designation 10.5 in foundation and plinth in cement Mortar 1:4. (HSR 7.21.1)
498.01
-
-
... More
12mm thick Plastering with cement mortar (1:3) on brick work in sub-structure as per Technical Specifications (HSR 11.5.2)
1194.99
-
-
... More
Providing and erecting a 'W' metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be f1Xed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 (HSR.34.32.1)
400
-
-
... More
Steel reinforcement Thermo-Mechanically Treated bars of grade Fe-500D or more for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level.
Note: - Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 6.33.6) Note:- If any discrepancy found in the unit/Nomenclature in the items of BOQ. The nomenclature of HSR/MoRD shall be applicable.
NOTE- It may kindly be noted that the contractorwould be obligated to carry out 05 years paid maintenance as per the rates fixed in the DNIT. However, the items of 05 yearsmaintenance shall not be part of BOQ to avoid any confusion.
8.02
-
-