Haryana Power Generation Corporation Limited Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 1,46,300Document Cost
₹ 1,180Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HBC_417827_1Tender No
2024BA40DEEB 1A24 4CAE 93AF DC8DBBF30F92713PGCTender Authority
Haryana Power Generation Corporation Limited ViewPurchaser Address
-Website
http://www.hpgcl.org.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Servicing of all Wall Blowers (56 Nos.) & all LRSBs (18 Nos) and Sampling Coolers (As per scope of work Referring Item No. 6) for 250 MW, Unit-8, PTPS, Panipat
1
-
-
... More
Overhauling of Drum Internals and Hangers & Supports (As per scope of work Referring Item No. 7 & 8) for 250 MW, Unit-8, PTPS, Panipat
1
-
-
... More
Repairing of Pent House, SS wire mesh in BAH, Economizer Hoppers and seal plate (As per scope of work Referring Item No. 9) for 250 MW, Unit-8, PTPS, Panipat
1
-
-
... More
Servicing/Replacement of HP/LP Valves Including Safety Valves etc. (As per scope of work Referring Item No. 11) for 250 MW, Unit-8, PTPS, Panipat
1
-
-
... More
Overhauling of Bottom Water Wall Ring Header (As per scope of work Referring Item No. 12) for 250 MW, Unit-8, PTPS, Panipat
1
-
-
... More
Service & Setting of safety valves: Drum Safety valve for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Service & Setting of safety valves: M.S. Safety Valve/ERV for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Service & Setting of safety valves: R.H Safety Valve/ERV for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Service & Setting of safety valves: PRDS Safety valve for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Service & Setting of safety valves: SH ERV including Pilot valve for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Service & Setting of safety valves: RH ERV including Pilot valve for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Lifting of any LTSH coil (Upper & lower) repositioning after carrying out repairs / replacement wherever required. (HP joints and radiography excluded) for 250 MW, Unit-8 (for unit rate variation purpose)
2
-
-
... More
Lifting of any ECO coil (Upper & lower) repositioning after carrying out repairs / replacement wherever required. (HP joints and radiography excluded) for 250 MW, Unit-8 (for unit rate variation purpose)
2
-
-
... More
Repair & Replacement of any castle baffle for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Replacement of Shield / Shroud for 250 MW, Unit-8 (for unit rate variation purpose)
100
-
-
... More
Providing refractory for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
HP joints including cutting, edge preparation etc. up to tube dia 76 mm diameter. for 250 MW, Unit-8 (for unit rate variation purpose)
100
-
-
... More
Fin Welding for 250 MW, Unit-8 (for unit rate variation purpose)
10
-
-
... More
Fabrication of Pressure Part Bend out of boiler tube of various size up to 76.10mm. for 250 MW, Unit-8 (for unit rate variation purpose)
5
-
-
... More
Thickness measurement of tubes by D-metering for 250 MW, Unit-8 (for unit rate variation purpose)
100
-
-
... More
Servicing of Wall Blower. for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Servicing of hanger in critical piping for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Replacement of hanger in critical piping for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Repair / Servicing of oil burner valve and replacement. for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Removal of oil tip & its re-fitting including alignment. for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Removal of End air tip & its re-fitting including alignment. for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Removal of Air nozzle tip, Repair / Replacement of worn out portion, if required. Assembling & re-fitting of the same including its alignment. for 250 MW, Unit-8 (for unit rate variation purpose)
6
-
-
... More
Re-alignment of re-heater/platen superheater coils as per requirement by locking them with spacer tube & fixing of male/female connectors wherever required after necessary pulling of coils. Scaffolding, if required for execution of work is also included in the scope of work of contractors for 250 MW, Unit-8 (for unit rate variation purpose)
15
-
-
... More
Alignment of Final Super Heater coils as per requirement by locking them with scallop bar wherever required after necessary pulling of coils including erection and dismantlement of scaffolding for execution of work for 250 MW, Unit-8 (for unit rate variation purpose)
15
-
-
... More
Making work space for carrying out inspection & repairs (build ups, shielding etc.) in one LTSH coil by pulling adjacent modules by push-pull machine/chain pulley block for 250 MW, Unit-8 (for unit rate variation purpose)
15
-
-
... More
DPT of stub joints / hand holes (Pent house, SHH-9, intermediate header, ECO inlet header etc.), safety valves welds with DPT kit for 250 MW, Unit-8 (for unit rate variation purpose)
10
-
-
... More
Removal of skin casing, re-fixing of skin casing after repair in pent house for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Replacement of gasket of manhole of Boiler drum for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Replacement of one male connector in Re-heater / superheater for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Replacement of one female connector in Re-heater / superheater for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Servicing of HP/LP Valves, traps, NRVs: Up to 25 mm for 250 MW, Unit-8 (for unit rate variation purpose)
2
-
-
... More
Servicing of HP/LP Valves, traps, NRVs: 40 mm to 50 mm for 250 MW, Unit-8 (for unit rate variation purpose)
2
-
-
... More
Servicing of HP/LP Valves, traps, NRVs: 65 mm to 100 mm for 250 MW, Unit-8 (for unit rate variation purpose)
2
-
-
... More
Servicing of HP/LP Valves, traps, NRVs: 150 mm to 200 mm for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Servicing of HP/LP Valves, traps, NRVs: 250 mm & above for 250 MW, Unit-8 (for unit rate variation purpose)
1
-
-
... More
Replacement of HP / LP piping (in per Mtr. running length): Up to 25 mm for 250 MW, Unit-8 (for unit rate variation purpose)
5
-
-
... More
Replacement of HP / LP piping (in per Mtr. running length): 26 mm to 50 mm for 250 MW, Unit-8 (for unit rate variation purpose)
5
-
-
... More
Replacement of HP/ LP valves, traps, NRVs: Size Up to 25 mm for 250 MW, Unit-8 (for unit rate variation purpose)
5
-
-
... More
Replacement of HP/ LP valves, traps, NRVs: 40 mm to 50 mm for 250 MW, Unit-8 (for unit rate variation purpose)
5
-
-
... More
Replacement of HP/ LP valves, traps, NRVs: 65 mm to 100 mm for 250 MW, Unit-8 (for unit rate variation purpose)
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%