Haryana Power Generation Corporation Limited Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Haryana Power Generation Corporation Limited - HPGCL Tender

Works
Eprocure
Opening Date31 May 2024
Closing Date25 Jul 2024
Tender Amount₹ 64,79,911 
Notes
Download

Costs

  • EMD

    ₹ 1,29,600
  • Document Cost

    ₹ 1,180
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING & CALIB OF ACTUATORS FOR PNEUMATIC CONTROL VALVE SYSTEMS INCLUDING INSTALLATION ABOVE 200MM

40

77571

1939.29

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING & CALIB. OF POWER CYLINDER OF SADC SYSTEM INCLUDING INSTALLATION

240

64632

269.3

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING & CALIB. OF POWER CYLINDER OF HOT AIR/COLD AIR DAMPER/PRIMARY AIR THROUGH MILL / BP AIR INCLUDING INSTALLATION

120

129266

1077.22

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING & CALIB. OF POWER CYLINDER OF ID/FD/PA/SCAPH/BFP SCOOP TUBE & VANE CONTROL INCLUDING INSTALLATION

80

129383

1617.29

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING & CALIB. OF POWER CYLINDER OF BURNER TILT MATHANISM INCLUDING INSTALLATION

24

38814

1617.29

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING & CALIB. OF POWER CYLINDER OF SEAL AIR CONTROL DAMPER INCLUDING INSTALLATION

36

15543

431.77

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING & CALIB. OF POWER CYLINDER OF PURGE AIR DAMPER / SEAL AIR DISCHARGE DAMPER INCLUDING INSTALLATION

80

21544

269.3

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING & CALIB. OF FEEDBACK TRANSMITTERS INCLUDING INSTALLATION

300

21513

71.71

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING & CALIB. OF POSITIONER INCLUDING INSTALLATION

200

14342

71.71

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING & CALIB. OF I/P CONVERTOR INCLUDING INSTALLATION

200

14342

71.71

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING & CALIB. OF AFR/Air LOCK RELAY INCLUDING INSTALLATION

300

21513

71.71

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING & CALIB. OF Solenoid Valves of Actuators INCLUDING INSTALLATION

120

13524

112.7

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING & CALIB. OF POWER CYLINDER OF PA Gen Inlet gate/Feeder Outlet gate INCLUDING INSTALLATION

36

58196

1616.56

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. SERVICING OF Limit Switches of Actuators INCLUDING INSTALLATION

300

21513

71.71

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. Removal, Checking , Testing and Reinstallation of PFT/LVDT of HPLB byepass , HPCV, IPCV, LPBP, Seal Steam control Valves and governing rack.

80

53860

673.26

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. Removal, Checking , Testing and Reinstallation of LLD probe and its amplifier

40

26930

673.26

... More
Round the clock preventive/breakdown maintenance of Pneumatic Actuators (installed at various locations in the plant) along with its accessories which also includes the repair and replacement (up to sub-assembly level)of positioners,I /P converters, filter regulators, Air Lock Relays, Solenoid valves, Copper/ SS tubing, limit switches, position feedback transmitter and the calibration of positioners, position feedback transmitter, I/P converters and the complete actuator installed in Unit-7&8. Removal, Checking , Testing and Reinstallation of Displacer/capacitance/US type LVL TX

80

53860

673.26

... More
Preventive, Breakdown and Routine maintenance and monitoring of complete SWAS (Steam & Water Analysis System) Dry & Wet panels including online water/steam & gas analyzers and DM Plant analytical and local Instrumentation installed in Unit-7&8. DISMENTLING/CLEANING BY WIRE BRUSH & REFITTING OR REPLACEMENT OF SAMPLE STRAINER/FILTER

100

5415

54.15

... More
Preventive, Breakdown and Routine maintenance and monitoring of complete SWAS (Steam & Water Analysis System) Dry & Wet panels including online water/steam & gas analyzers and DM Plant analytical and local Instrumentation installed in Unit-7&8. DISMENTLING/CLEANING BY WIRE BRUSH & REFITTING OR REPLACEMENT OF PR. REDUCER VALVE IN HIGH PR. LINE/VREL

60

5444

90.74

... More
Preventive, Breakdown and Routine maintenance and monitoring of complete SWAS (Steam & Water Analysis System) Dry & Wet panels including online water/steam & gas analyzers and DM Plant analytical and local Instrumentation installed in Unit-7&8. DISMENTLING/CLEANING BY WIRE BRUSH & REFITTING OR REPLACEMENT OF CATION COLOUMN

120

6498

54.15

... More
Preventive, Breakdown and Routine maintenance and monitoring of complete SWAS (Steam & Water Analysis System) Dry & Wet panels including online water/steam & gas analyzers and DM Plant analytical and local Instrumentation installed in Unit-7&8. DISMENTLING/CLEANING BY WIRE BRUSH & REFITTING OR REPLACEMENT OF ROTAMETERS

160

7024

43.9

... More
Preventive, Breakdown and Routine maintenance and monitoring of complete SWAS (Steam & Water Analysis System) Dry & Wet panels including online water/steam & gas analyzers and DM Plant analytical and local Instrumentation installed in Unit-7&8. SERVICING & MAINTENANCE of PRIMARY SAMPLE COOLER

16

2294

143.43

... More
Preventive, Breakdown and Routine maintenance and monitoring of complete SWAS (Steam & Water Analysis System) Dry & Wet panels including online water/steam & gas analyzers and DM Plant analytical and local Instrumentation installed in Unit-7&8. SERVICING & MAINTENANCE of SECONDARY SAMPLE COOLER

20

2868

143.43

... More
Preventive, Breakdown and Routine maintenance and monitoring of complete SWAS (Steam & Water Analysis System) Dry & Wet panels including online water/steam & gas analyzers and DM Plant analytical and local Instrumentation installed in Unit-7&8. MAINTENANCE OF SWAS CHILLER UNIT

16

6931

433.24

... More
Preventive, Breakdown and Routine maintenance and monitoring of complete SWAS (Steam & Water Analysis System) Dry & Wet panels including online water/steam & gas analyzers and DM Plant analytical and local Instrumentation installed in Unit-7&8. Checking, monitering of SWAS Samples, flushing of lines, arreasting of leakages if any, replacemt of required regents,

600

132606

221.01

... More
Preventive, Breakdown and Routine maintenance and monitoring of complete SWAS (Steam & Water Analysis System) Dry & Wet panels including online water/steam & gas analyzers and DM Plant analytical and local Instrumentation installed in Unit-7&8. Removal/Installtion/servicing of SWAS /DM plant sensor/Transmitters

400

45080

112.7

... More
Preventive, Breakdown and Routine maintenance and monitoring of complete SWAS (Steam & Water Analysis System) Dry & Wet panels including online water/steam & gas analyzers and DM Plant analytical and local Instrumentation installed in Unit-7&8. REPAIR OF ZIRCONIA PROBE SHIELD BY EDGE PREPARATION OF NEW PIPE & WELDING

16

8617

538.61

... More
Preventive, Breakdown and Routine maintenance and monitoring of complete SWAS (Steam & Water Analysis System) Dry & Wet panels including online water/steam & gas analyzers and DM Plant analytical and local Instrumentation installed in Unit-7&8. Removal, cleaning & installation/rotation of O2 probe and erosion shield

80

32316

403.95

... More
Preventive, Breakdown and Routine maintenance and monitoring of complete SWAS (Steam & Water Analysis System) Dry & Wet panels including online water/steam & gas analyzers and DM Plant analytical and local Instrumentation installed in Unit-7&8. SERVICING & MAINTENANCE of On/Off actuators in DM Plant /Clorination Plant

100

26930

269.3

... More
Preventive, Breakdown and Routine maintenance and monitoring of complete SWAS (Steam & Water Analysis System) Dry & Wet panels including online water/steam & gas analyzers and DM Plant analytical and local Instrumentation installed in Unit-7&8. SERVICING & MAINTENANCE of Limit Switches, solenoids , Pressure Switches in DM Plant /Clorination Plant.

240

27048

112.7

... More
Cleaning and Maintenance Assistance for equipments installed in Unit-7&8. Main conventional desks and UCB, HMI workstations alongwith furniture, LVS, HMI Printers in Unit-7.

624

137910

221.01

... More
Cleaning and Maintenance Assistance for equipments installed in Unit-7&8. Main conventional desks and UCB, HMI workstations alongwith furniture, LVS, HMI Printers in Unit-8.

624

137910

221.01

... More
Cleaning and Maintenance Assistance for equipments installed in Unit-7&8. Control Panels of ATRS, Station C&I , Mills, Feeders, UPS, FSSS installed in main control room CWPH room in Unit-7.

624

137910

221.01

... More
Cleaning and Maintenance Assistance for equipments installed in Unit-7&8. Control Panels of ATRS, Station C&I , Mills, Feeders, UPS, FSSS installed in main control room CWPH room in Unit-8.

624

137910

221.01

... More
Cleaning and Maintenance Assistance for equipments installed in Unit-7&8. Local instruments, racks & control panels installed in Turbine and Boiler area in Unit-7.

624

137910

221.01

... More
Cleaning and Maintenance Assistance for equipments installed in Unit-7&8. Local instruments, racks & control panels installed in Turbine and Boiler area in Unit-8.

624

137910

221.01

... More
Cleaning and Maintenance Assistance for equipments installed in Unit-7&8. Local instruments, Junction boxes, racks & control panels installed in BOP area in Unit-7.

624

137910

221.01

... More
Cleaning and Maintenance Assistance for equipments installed in Unit-7&8. Local instruments, Junction boxes, racks & control panels installed in BOP area in Unit-8.

624

137910

221.01

... More
Cleaning and Maintenance Assistance for equipments installed in Unit-7&8. Internal Cleaning of Control Panels alongwith cards & other modules of ATRS, Station C&I , Mills, Feeders, UPS, CWPH, DM plant ,FSSS installed in main control room & sites of Unit-7

240

138400

576.67

... More
Cleaning and Maintenance Assistance for equipments installed in Unit-7&8. Internal Cleaning of Control Panels alongwith cards & other modules of ATRS, Station C&I , Mills, Feeders, UPS, CWPH, DM plant ,FSSS installed in main control room & sites of Unit-8.

240

138400

576.67

... More
Removal, cleaning & installation, Testing / servicing of HEA Igniters & assembly and Flame Scanners installed in Unit-7&8. Removal,Cleaning & reinstallation of HEA Igniters & assembly installed in Unit-7

600

57960

96.6

... More
Removal, cleaning & installation, Testing / servicing of HEA Igniters & assembly and Flame Scanners installed in Unit-7&8. Removal,Cleaning & reinstallation of HEA Igniters & assembly installed Unit-8

600

57960

96.6

... More
Removal, cleaning & installation, Testing / servicing of HEA Igniters & assembly and Flame Scanners installed in Unit-7&8. Testing/servicing of HEA Igniters & assembly installed Unit-7

40

7669

191.74

... More
Removal, cleaning & installation, Testing / servicing of HEA Igniters & assembly and Flame Scanners installed in Unit-7&8. Testing/servicing of HEA Igniters & assembly installed Unit-8

40

7669

191.74

... More
Removal, cleaning & installation, Testing / servicing of HEA Igniters & assembly and Flame Scanners installed in Unit-7&8. SILVER BRAZING OF HEA FLEXIBLE CABLE/HI TEMP WIRE

20

3834

191.74

... More
Removal, cleaning & installation, Testing / servicing of HEA Igniters & assembly and Flame Scanners installed in Unit-7&8. Removal, Cleaning & reinstallation flame Scanners installed Unit-7

1000

96600

96.6

... More
Removal, cleaning & installation, Testing / servicing of HEA Igniters & assembly and Flame Scanners installed in Unit-7&8. Removal, Cleaning & reinstallation flame Scanners installed Unit-8

1000

96600

96.6

... More
Removal, cleaning & installation, Testing / servicing of HEA Igniters & assembly and Flame Scanners installed in Unit-7&8. Testing/servicing of flame Scanners including fiber optic cables installed Unit-7

120

11592

96.6

... More
Removal, cleaning & installation, Testing / servicing of HEA Igniters & assembly and Flame Scanners installed in Unit-7&8. Testing/servicing of flame Scanners including fiber optic cables installed Unit-8

120

11592

96.6

... More
Maintenance of Mills , Feeders & its and local Instrumentation installed in Unit - 7&8. Maintenance of Mill DP system including cleaning, flushing of lines, clearing of choking in lines, brazing of copper tubes & replacement if any etc

220

159387

724.49

... More
Maintenance of Mills , Feeders & its and local Instrumentation installed in Unit-7&8. Cleaning, servicing & replacement of Tachgenerator & excitation coil.

48

11802

245.89

... More
Maintenance of Mills , Feeders & its and local Instrumentation installed in Unit-7&8. Maintenance of Steam inerting & fire fighting control panels of Mills

48

11802

245.89

... More
Maintenance of Mills , Feeders & its and local Instrumentation installed in Unit-7&8. Maintenance of Noise Valve Tx, Jaw clutch system & Greasing mechanism switches.

72

17704

245.89

... More
Maintenance of Mills , Feeders & its and local Instrumentation installed in Unit-7&8. Maintenance of Feeder Limit Switches, solenoids , Pressure Switches, LSFB, LSFD.

400

45080

112.7

... More
Preventive, Breakdown and Routine maintenance of Fire detection and alarm system for Unit-7&8. Removal & reinstalltion of Fire detectors

900

32940

36.6

... More
Preventive, Breakdown and Routine maintenance of Fire detection and alarm system for Unit-7&8. HORN SPEAKERS

64

2342

36.6

... More
Preventive, Breakdown and Routine maintenance of Fire detection and alarm system for Unit-7&8. DV Solenoid Valves, Press Switches , CR/CT1

120

13524

112.7

... More
Preventive, Breakdown and Routine maintenance of Fire detection and alarm system for Unit-7&8. WALL MOUNTED MCP

120

4392

36.6

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. LOCAL PR. GAUGES

800

90160

112.7

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. LOCAL TEMP-GAUGES WITHOUT CAPILLARY

700

78890

112.7

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. LOCAL TEMP-GAUGES WITH CAPILLARY

120

13524

112.7

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. LOCAL PR. SWITCHES

300

33810

112.7

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. LOCAL TEMP. SWITCHES WITHOUT CAPILLARY

80

9016

112.7

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. LOCAL TEMP-SWITCHES WITH CAPILLARY

60

6762

112.7

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. LEVEL SWITCHES LOW PR. AREA UPTO 10 KG./CM2

60

6762

112.7

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. LEVEL SWITCH HIGH PR. AREA ABOVE 10Kg/cm2

50

10757

215.15

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. SOLENOID VALVES

500

56350

112.7

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. PRESS ,LEVEL , FLOW TRANSMITTER

800

90160

112.7

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. LIMIT SWITCHES

600

67620

112.7

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. REPLACEMENT,CLEANING & REINSTALLATION OF hydrastep electrodes

120

48474

403.95

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. REPLACEMENT,CLEANING & REINSTALLATION OF RTD/Thermocouple Connection Tightening

1300

146510

112.7

... More
DISMENTALLING /CLEANING & REFITTING OR REPLACEMENT OF LOCAL GAUGES/PR. SWITCHES, TEMP.TX, PR. TRANSMITTERS, LEVEL SWITCH, TEMP. SWITCES including transportation from site to lab & back. REPLACEMENT,CLEANING & REINSTALLATION OF Ultra sonic Level & flow transmitters

60

24237

403.95

... More
Mechanical Jobs LAYING INCLUDING DRESSING OF S.S tube/ IMPULSE PIPE LINE UPTO 10MM NB

60

11504

191.74

... More
Mechanical Jobs LAYING INCLUDING DRESSING OF S.S tube/ IMPULSE PIPE LINE FROM 11MM NB TO 25MM NB

40

11533

288.33

... More
Mechanical Jobs LAYING/Replacement INCLUDING DRESSING OF CU/PVC 6/8mm

200

8780

43.9

... More
Mechanical Jobs Arreasting of leakages in impluse lines SS/CU

400

22832

57.08

... More
Mechanical Jobs REMOVAL/DISMENTLING/REPLACEMENT OF Manifolds 3 way/5way, Isolation valves 1/2", 3/8"

100

13172

131.72

... More
Mechanical Jobs REMOVAL/DISMENTLING/REPLACEMENT OF PIPE LINE UPTO 25NB by proper hangers/supports

40

11533

288.33

... More
Mechanical Jobs Welding/repair OF PIPE LINE UPTO 25NB (SS/CS/GI), Thermowells, stubs, joints etc

100

10685

106.85

... More
Mechanical Jobs FLUSHING/CLEANING OF IMPULSE PIPE LINE WITH SERVICE AIR WHICH ALSO INVOLVES DISMANTLING & NORMALIZING AFTER FLUSHING/ARRESTING OF LEAKAGES, IF ANY.

700

65569

93.67

... More
Mechanical Jobs Fabrication /repair of Canopy for C&I equipments 8 sqM

20

9601

480.06

... More
VIBRATION PICK-UP DISMENTALLING/CLEANING & REFITTING OR REPLACEMENT OF SHAFT & PEDESTAL VIBRATION PICK-ups of Main turbine

60

40395

673.26

... More
VIBRATION PICK-UP DISMENTALLING/CLEANING & REFITTING OF AXIAL SHAFT EXPANSION PICK UP & SPEED SENSORS of Pumps

100

10391

103.91

... More
VIBRATION PICK-UP DISMENTALLING/CLEANING & REFITTING OF AXIAL SHAFT EXPANSION PICK UP & SPEED SENSORS of Fans etc

60

6234

103.91

... More
SSDP CHARGER / OTHER / Battery Bank Removal, checking & reinstallation of cooling Fans

80

11474

143.43

... More
SSDP CHARGER / OTHER / Battery Bank Cleaning and conection tightening of battery terminals of UPS battery Bank

16

18429

1151.86

... More
Installation/dismentelling of control and instruments /compenseting cables/Network cables including cable route tracing, fault finding, cutting jolinting termination etc Up to 6PX0.5MM2 TO 12 P X 0.5MM2

2000

8760

4.38

... More
Installation/dismentelling of control and instruments /compenseting cables/Network cables including cable route tracing, fault finding, cutting jolinting termination etc 1PX1.5MM2 TO 5PX1.5MM2

2000

8760

4.38

... More
Installation/dismentelling of control and instruments /compenseting cables/Network cables including cable route tracing, fault finding, cutting jolinting termination etc 6PX1.5MM2 TO 12 P X 1.5MM2

1000

9510

9.51

... More
Installation/dismentelling of control and instruments /compenseting cables/Network cables including cable route tracing, fault finding, cutting jolinting termination etc Network Ethernet cable

400

3804

9.51

... More
Installation/dismentelling of control and instruments /compenseting cables/Network cables including cable route tracing, fault finding, cutting jolinting termination etc FO CABLE

200

6732

33.66

... More
Installation/dismentelling of control and instruments /compenseting cables/Network cables including cable route tracing, fault finding, cutting jolinting termination etc TERMINATION OF CONTROL , INSTRUMENTATION AND COMPENSATING OF 0.5/1.5

800

5864

7.33

... More
Installation/dismentelling of control and instruments /compenseting cables/Network cables including cable route tracing, fault finding, cutting jolinting termination etc Cable Glanding/ DRESSING/ STRAIGHT THROUGH LUGS OF CABLE 0.5/1.5 SIZE

800

5864

7.33

... More
INSTALLATION OF CABLE TRAYS UPTO 150MMX50MM SIZE

40

2166

54.15

... More
INSTALLATION OF CABLE TRAYS ABOVE 150MMX50MM UPTO 450MMX50MM

40

6439

160.99

... More
INSTALLATION OF CABLE TRAYS REMOVAL OF CABLE TRAYS UPTO 450MM

80

3512

43.9

... More
INSTALLATION OF CABLE TRAYS FABRICATION OF SUPPORTING STEEL STRUCTURE AS PER DRAWING & SPEC. INCLUDING PAINTING.

4

30168

7542.01

... More
MAINTENANCE OF FIELD JUNCTION BOXES REPAIR/REPLACEMENT OF HINGES

40

2283

57.08

... More
MAINTENANCE OF FIELD JUNCTION BOXES FIXING OF RUBBER GASKETS/LINING WITH MATERIAL

60

6411

106.85

... More
MAINTENANCE OF FIELD JUNCTION BOXES REPLACEMENT OF T.Bs INCLUDING DE-TERMINATION & TERMINATION

160

17096

106.85

... More
MAINTENANCE OF FIELD JUNCTION BOXES INSTALLATION / DISMENTALLING / SEALING OF JB

40

4274

106.85

... More
MAINTENANCE OF FIELD JUNCTION BOXES PANEL SEALING WITH GLASS PUTTY & CHEMICAL

80

8548

106.85

... More
DRILLING OF HOLES from 6mm to 15mm DIA, OTHER THAN PANELS

100

1902

19.02

... More
DRILLING OF HOLES Above 15mm DIA, OTHER THAN PANELS

60

1668

27.81

... More
DRILLING OF HOLES from 6mm to 15mm DIA, ON PANELS

80

3864

48.3

... More
DRILLING OF HOLES Above 15mm DIA, ON PANELS

40

3044

76.11

... More
Handling/Shifting/TRANSPORTATION of C&I equipment/ MATERIAL from O&M Store/other Units of PTPS to Unit 7 & 8 & vice versa Material transportation 10Kg to 100Kg

100

24003

240.03

... More
Handling/Shifting/TRANSPORTATION of C&I equipment/ MATERIAL from O&M Store/other Units of PTPS to Unit 7 & 8 & vice versa Material transportation 101Kg & above

40

15397

384.93

... More
Extra manpower Man Days

600

147534

245.89



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.