Haryana Power Generation Corporation Limited Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Haryana Power Generation Corporation Limited - HPGCL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Jul 2024
Closing Date20 Aug 2024
Tender AmountRefer Documents 
Notes
Download

Costs

  • EMD

    ₹ 1,27,500
  • Document Cost

    ₹ 1,180
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing New Insulation with refixing of old cladding in Boiler Furnace Wind Box and APH Area. Insulation (Type: Rock Wool Felt, Thickness-200mm) Netting: GI, Cladding (Old Corrugated sheet)

150

-

-

... More
Providing New Insulation with New Cladding in Boiler Furnace Wind Box and APH Area. Insulation (Type: Rock Wool Felt, Thickness-190 mm) Netting: GI, Cladding (Corrugated Al. Sheet, Thickness: 1.2 mm)

100

-

-

... More
Providing New Insulation with refixing of old cladding in Drum DownComers pipers 24 to 80 m elevation, ring header including man holes of ring header at 9 meter elevation, main steam to PRDS line, main steam line and ID fan area. Insulation (Type: Rock Wool Felt, Thickness-150 mm) Netting: GI, Cladding (Old plain sheet)

50

-

-

... More
Providing New Insulation with new cladding in Drum Down-Comers pipers 24 to 80 m elevation, ring header including man holes of ring header at 9 meter elevation, main steam to PRDS line, main steam line and ID fan area. Insulation (Type: Rock Wool Felt, Thickness-150 mm) Netting: GI, Cladding (Al. Sheet, Thickness: 0.56 mm)

50

-

-

... More
Providing New Insulation with refixing of old Cladding in Bottom of Zpanel at 9 meter elevation and ESP Hopper area. Insulation (Type: Rock Wool Felt, Thickness-150 mm) Netting: GI, Cladding (Old Corrugated sheet)

100

-

-

... More
Providing New Insulation with new cladding in Bottom of Z-panel at 9 meter elevation and ESP Hopper area. Insulation (Type: Rock Wool Felt, Thickness-190 mm) Netting: GI, Cladding (Corrugated Al. Sheet, Thickness: 1.2 mm)

100

-

-

... More
Providing New Insulation with new cladding in Fuel Oil Lines/after Vent/Drain line valve i.e. Drum Vent, CBD Drain (Left and Right) and Vent, LTSH Drain line and Ring Header Drain Valve area. Insulation (Type: Rock Wool Felt, Thickness-50 mm) Netting: GI, Cladding (Al. Sheet, Thickness: 0.56 mm)

50

-

-

... More
Filling Inside Cover Plates. Providing only new Insulation in Burner Panel area. Insulation (Type: Rock Wool Felt, Thickness-120 mm) Netting: GI.

500

-

-

... More
Providing New Insulation with New Cladding in Vent/Drain i.e. Drum Vent, CBD Drain (Left and Right), SH Spray Line and Vent, LTSH Drain line and Ring Header Drain Valve area. Insulation (Type: Rock Wool Felt, Thickness-100 mm) Netting: GI. Cladding (Al. Sheet, Thickness: 0.56 mm)

100

-

-

... More
Providing New Insulation with New Cladding in Primary and secondary Hot Air Duct at, 6 M to 30 M elevation area. Insulation (Type: Rock Wool Felt, Thickness-170 mm) Netting: GI. Cladding (Corrugated Al. Sheet Thickness: 1.2 mm)

450

-

-

... More
Providing New Insulation with refixing of old cladding in Primary and secondary Hot Air Duct at , 6 M to 30 M elevation area. Insulation (Type: Rock Wool Felt, Thickness-170 mm) Netting: GI. Cladding (Old Corrugated Sheet)

100

-

-

... More
Providing New Insulation with New Cladding in Flue Gas Duct area. Insulation (Type: Rock Wool Felt, Thickness-40 mm) Netting: GI. Cladding (Corrugated Al. Sheet Thickness-1.2 mm )

500

-

-

... More
Providing New Insulation with refixing of old cladding in Flue Gas Duct area. Insulation (Type: Rock Wool Felt, Thickness-40 mm) Netting: GI. Cladding (Old Corrugated Sheet)

600

-

-

... More
Providing New Cladding sheet on existing insulation in any area boiler/ hot duct/cold duct/wind box/ ESP hopper /ESP duct. Cladding (Corrugated Sheet Al Thickness: 1.2 mm)

100

-

-

... More
Providing New Cladding sheet on existing insulation in Any area line of vent/drain/main steam line/ bottom Ring Header line. Cladding (Al. Sheet Thickness: 0.56 mm)

50

-

-

... More
Refixing of Old cladding Sheet in any of the area pertaining to Boiler and its auxiliaries. Cladding (Old Corrugated/ plain sheet)

200

-

-

... More
Thermal Insulation works pertaining to Turbine and its auxiliaries

-

-

-

... More
Alumina silicate fibre block insulation with bottom plaster, Thickness: 70x3mm, Area: HIP turbine (Cylinder cover) Main Turbine Site.

40

-

-

... More
Alumina silicate fibre block type insulation with bottom plaster, Thickness: 60x3mm, Area: HIP turbine (Cylinder base) Main Turbine Site

40

-

-

... More
Alumina silicate fibre type insulation , Thickness: 80x2mm, Area: steam inlet sleeve, HIP turbine Main Turbine Site

12

-

-

... More
Alumina silicate fibre type, Thickness: 40x2mm, Area: Dum Ring balance piping, HIP turbine Main Turbine Site.

20

-

-

... More
Alumina silicate fibre block type insulation with bottom plaster, Thickness: 80x2mm, Area: MSV body Main Turbine Site

38

-

-

... More
Alumina silicate fibre pipe type insulation with bottom plaster, Thickness: F340x70 and F480x50, Area: GV piping and flanges Main Turbine Site

60

-

-

... More
Alumina silicate fibre block type insulation with bottom plaster, Thickness: 80x2mm, Area: RSV and RIV body and cover Main Turbine Site

25

-

-

... More
Alumina silicate fibre pipe type insulation with bottom plaster, Thickness: 80x2mm, Area: RSV piping and flanges Main Turbine Site

45

-

-

... More
Alumina silicate fibre block type insulation, Thickness: 60 +40mm, Area: cross-over piping and flanges Main Turbine Site

100

-

-

... More
Alumina silicate Felt, Insulation Thickness-160 mm for TDBFP in r/o TGM-I, RGTPP

40

-

-

... More
Alumina silicate Felt ,Thickness 120 mm in r/o TGM-I, RGTPP

30

-

-

... More
Alumina silicate Felt ,Thickness 100 mm in r/o TGM-I, RGTPP

40

-

-

... More
Alumina silicate Felt ,Thickness 50 mm in r/o TGM-I, RGTPP

30

-

-

... More
Rock Wool felt ,Insulation Thickness 160 mm in r/o TGM-I, RGTPP

40

-

-

... More
Rock Wool felt ,Insulation Thickness120 mm in r/o TGM-I, RGTPP

40

-

-

... More
Rock Wool felt,Insulation Thickness 100 mm in r/o TGM-I, RGTPP

120

-

-

... More
Rock Wool felt ,Insulation Thickness 80 mm in r/o TGM-I, RGTPP

100

-

-

... More
Rock Wool felt , Insulation Thickness 50 mm in r/o TGM-I, RGTPP

100

-

-

... More
Cladding in r/o TGM-I, RGTPP

150

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.