Haryana Police Housing Corporation Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Haryana Police Housing Corporation - HPHC Tender

Works
Civil And Construction
Drainage Work
Eprocure
Opening Date23 Dec 2024
Closing Soon2 Jan 2025
Tender Amount₹ 1,51,46,232 
Notes
Download

Costs

  • EMD

    ₹ 3,02,000
  • Document Cost

    ₹ 15,000
  • Tender Fee

    ₹ 1,180

Summary

Onstruction Of Sewage Treatment Plant In High Security Jail Campus At Rohtak (0.50 M.l.d). Construction Of Sewage Treatment Plant In High Security Jail Campus At Rohtak (0.50 M.l.d).

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
[10.25.1.1]Providing and laying of marble chips skirting up to 30 cm height, rubbed and polished to granolithic finish, top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from smallest to 4 mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume : 1.1. 18 mm thick with under layer 12 mm thick in cement plaster 1:3 (1 cement : 3 coarse sand) : Dark shade pigment with ordinary cement [Through Rate]

3.74

476

1780.24

... More
[10.8]Providing and laying of conglomerate floor 40mm thick cement concrete topping 1:2:4 [Through Rate]

17.08

181

3091.48

... More
[11.4.2]10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) [Through Rate]

32.41

114

3694.74

... More
[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate]

89.32

113

10093.16

... More
[11.61.1]White washing with lime to give an even shade : 1. New work (three or more coats) [Through Rate]

29.61

13

384.93

... More
[11.63]Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade. [Through Rate]

76.09

29

2206.61

... More
[11.77]Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. [Through Rate]

14.79

19

281.01

... More
[11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. [Through Rate]

14.79

31

458.49

... More
[11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate]

661.5

88

58212

... More
[12.36.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate]

5.57

2385

13284.45

... More
[12.61.1]Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 1. 125x65x2.12 mm [Through Rate]

12

32

384

... More
[12.65.1]Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 1. 300x16 mm [Through Rate]

1

149

149

... More
[13.21.1]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 1. Door Frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter [Through Rate]

22.1

947

20928.7

... More
[13.24.1]Providing and fixing glazing in door, window, ventilator shutters and partitions etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of Gasket / beading shall be paid as per respective item) 1. Float glass panes of 5.5mm thickness [Through Rate]

0.88

754

663.52

... More
[20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48" (1200mm) [Through Rate]

2

2054

4108

... More
[22.91.5]Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. External work 5. 40 mm dia nominal bore [Through Rate]

358

338

121004

... More
[23.1.1.1]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group A [Through Rate]

2

584

1168

... More
[23.1.2.1]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 2.1. Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. switch in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group A [Through Rate]

6

766

4596

... More
[23.1.4.1]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 4.1. Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required Group A [Through Rate]

2

867

1734

... More
[23.21]Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required [Through Rate]

5

48

240

... More
[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA [Through Rate]

1

10809

10809

... More
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate]

5

6130

30650

... More
[23.22.4.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.11. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate]

1

8083

8083

... More
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]

24

145

3480

... More
[23.27.2]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 2. M.S. pedestal of size 750 mm wide , 900 mm high , 300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 [Through Rate]

1

6352

6352

... More
[23.4.1.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A [Through Rate]

31

520

16120

... More
[23.4.4.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.1. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A [Through Rate]

24

725

17400

... More
[23.4.5.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.1. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A [Through Rate]

22

999

21978

... More
[23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]

288

53

15264

... More
[23.5.6.5]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate]

340

310

105400

... More
[23.6.1.1]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 1.1. MS CONDUIT and MS/GI BOX only for LIGHT/FAN/Call bell point wiring Group A [Through Rate]

1

334

334

... More
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]

492

32

15744

... More
[23.8.1.1]FITTING AND ACCESSORIES 1.1. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Switch 5 amp. on existing sheet. [Through Rate]

14

16

224

... More
[23.8.1.2]FITTING AND ACCESSORIES 1.2. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Wall socket 5 amp on existing sheet. [Through Rate]

2

29

58

... More
[23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate]

2

257

514

... More
[23.8.2.2]FITTING AND ACCESSORIES 2.2. Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 3 mm thick [Through Rate]

1350

12

16200

... More
[23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. [Through Rate]

3

95

285

... More
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]

9

2721

24489

... More
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]

9

652

5868

... More
[24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate]

388

180

69840

... More
[24.13.55]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 55. 70 Sq mm 4 core (UnArm.) [Through Rate]

291

473

137643

... More
[24.4.8.5]STREET LIGHT 8.5. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 7 Metre Long pole with top dia 75 0mm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm [Through Rate]

20

15685

313700

... More
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]

520

124

64480

... More
[24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate]

522

161

84042

... More
[4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate]

490.36

83

40699.88

... More
[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate]

14.74

46

678.04

... More
[6.1.4]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 4. 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) [Through Rate]

0.71

2911

2066.81

... More
[6.1.5]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 5. 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) [Through Rate]

7.01

2876

20160.76

... More
[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate]

3.37

2442

8229.54

... More
[6.10]Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. [Through Rate]

4.71

90

423.9

... More
[6.15.1]Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate]

31.2

5969

186232.8

... More
[6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate]

4.55

6113

27814.15

... More
[6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate]

0.85

4464

3794.4

... More
[6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate]

213.72

4502

962167.44

... More
[6.26.1]Extra for providing richer mixes up to plinth and at all floor levels. 1. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) [Through Rate]

1.91

59

112.69

... More
[6.29.2]Centering and shuttering including strutting, propping etc. and removal of form work for : 2. Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. [Through Rate]

160.37

282

45224.34

... More
[6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. [Through Rate]

557.5

282

157215

... More
[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate]

590.45

208

122813.6

... More
[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate]

48104.97

66

3174928.02

... More
[6.38.1]Providing and fixing up to floor four level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size) [Through Rate]

3.53

4049

14292.97

... More
[6.8.2]Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 2. 40mm thick [Through Rate]

4.71

133

626.43

... More
[7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]

9.49

4128

39174.72

... More
[7.45.1]Brick work with modular calcium silicate bricks machine moulded conforming to IS:4139, class designation 10 average compressive strength in super structure above plinth level up to floor IV level in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]

16.49

3784

62398.16

... More
[9.12.1]10cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow-dung) and covered with machine moulded tile bricks, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat. 1. With machine moulded common burnt clay non-modular brick tiles of class designation 12.5, conforming to IS 2690 [Through Rate]

30.06

491

14759.46

... More
[9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [Through Rate]

4

147

588

... More
[9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter [Through Rate]

6.3

200

1260

... More
[9.58.5.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5° 110 mm bend [Through Rate]

4

93

372

... More
Supply and erection of LED street light 70 watt , operation on single phase AC supply complete in all respect up to the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc.(3Q)

20

4019

80380

... More
Supply and erection of LED batten 20 watt (4 feet long) operation on single phase AC supply complete in all respect up to the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. (3Q)

2

391

782

... More
Design, Installation testing and commisioning of Sewerage treatment plant in MBBR(Moving Bed Bio Reactor) process electro Mech. work only for Sewege capciaty 500 cum/day. Outlet Parameter should be match for using the water for Gardening and Flushing purpose. Bidder should include following items as specified below suitable for 500 cum/day STP. (Bidder Must visit the site before quote) Depth of Incomming sewer 2.0 m to be consider. The STP shall be designed based on the following parameters: Inlet Parameters PH-6.5-8.5 TSS-250-300 PPM BOD300-350 PPM COD500-600 PPM Oil and Grease = ( 50 PPM Outlet Parameters post Tertiary PH-6.5-8.5 TSS50 PPM BOD 15 to 20 PPM COD100 PPM Oil and Grease = ( 5 PPM E Coli-Nil. Supply, installation, testing and commissioning of SS Manual coarse Screen with 10 mm size (3Q)

1

36562

36562

... More
Supply, installation, testing and commissioning of Submersible Raw Sewage Transfer Pumps, C.I. impeller and C.I. Body, connected to a inbuilt motor (with mechanical seal) suitable for 400/440 volts, 3 phase 50 cycles A.C. supply. (Make: Wilo / KSB/Kirloskar). Pumps suitable to handle solids upto 50 mm size with C.I. body, C.I. impeller with mechanical seal. Capacity/Flow Rate - 25M3/Hr Head-8-10 m 1 Set = 2 Nos. pump (1 working plus 1 standby) MOC C.I Casing/C.I. Impeller (3Q)

2

81562

163124

... More
Supply, Installation, testing and commissioning of belt type oil skimmer for removal of oil and grease present in effluent from kitchen area and restaurant area. Oil removal capacity – 0.50 LPH MOC of oil skimmer – MSEP, Motor HP-0.5 HP (3Q)

1

58500

58500

... More
Supply, installation, testing and commissioning of `Twin Iobe rotary air blowers for Equalization Tank, MBBR-I and II and Sludge Holding Tank capable of delivering 400 m3/tir of free air at 0.4 Kg/Cm2 driven through `V` belt or directly coupled through flexible coupling to a TEFCmotor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles AC supply. (IW plus 15). (Make: W2P) (3Q)

2

348750

697500

... More
Supply and installation of Air Grid (UPVC) for diffused aeration to be used along with air blowers in equalization tank and aeration tank as per its size. (Make Astral/Supreme/ Prince). 3Q

1

292500

292500

... More
MBBR – 1 and 11 Supply, installation, testing and commissioning of high surface area bio media and Tuve Set Media made of PP having surface area suitable to be used in MBBR Reactor (Make W2P). (3Q)

1

472500

472500

... More
MBBR – 1 and 11 Supply, installation, testing and commissioning of MEDIA Retaining screen, Make – W2P (3Q)

3

29250

87750

... More
Supplying, installing, testing and commissioning of Horizontal centrifugal filter feed pumps CI Head and Base,Cl Impeller along with motor, pressure gauge. NRV on delivery line and mechanical seal. The pump shall be suitable for 400/415 volts, 3 phase 50 cycles AC supply. (1W plus 15). (Make: Wilo/Kirloskar) Capacity/Flow Rate-25.0M3/Hr Head 30 to 35 M 1 Set 2 Nos. pump (1 working plus 1 standby) RPM-2900 MOC-C1 Casing/C.1. or SS Impeller (3Q)

2

85500

171000

... More
Providing, fixing, testing and commissioning of vertical self supporting Dual Media Filter, in MSEP vessels, pressure gauges at inlet and outlet, with Manual Butterfly Valves (Make W2P) Dual Medai Filter Sand Filter Capacity/Flow Rate-25.0M3/H Filtration rate approx.(15m3/hr/m2) Filter Dimensions 1500 mm X 1800mm Working pressure- 2.5 Kg/Sq.cm Test pressure 5.0 Kg/Sq.cm Supply and installation (3Q)

1

832500

832500

... More
Supply, installation, testing and commissioning of Chlorine dosing system comprising of: Chlorine Dosing Pump Capacity- (0-6 LPH) Qty. 2 (1w plus 1s) Make W2P Chlorine Dosing Tank Capacity- 250 Ltr Qty-1 no Make-Sintex/eqv. (3Q)

1

52875

52875

... More
Supply, installation, testing and commissioning of 4` Dial Type Pressure Gauges to measure pressure at the inlet and outlet of pumps, blowers and filters. (Make: H Guru). (3Q)

1

47250

47250

... More
Supply, installation, testing and commissioning of Electromagnetic Flow Meter in discharge of Sewage Transfer Pump In Treated Water Line. (Make-W2P/EandH). Flow-30.0 M3/Hr. Max. (3Q)

1

106875

106875

... More
SLUDGE DEWATERING SYSTEM. Supply, installation, testing and commissioning of Monoblock Pump for Sludge Recirculation with motor of C.I. Parts and mechanical seal complete with isolation and non-return valves, incuilding necessary fittings reduces, elbow etc to run. (Make: Wilo/ Kirloskar/Eq.) Capacity/Flow Rate 5 M3/Hr Head 8 to 10 m 1. Set 4 Nos. pump (1 working plus 1 standby) RPM 2900 MOC C.I Casing/C.I. Impeller/C.S. Shaft Location STP Room Supply and Installation. (3Q)

4

89437

357748

... More
SLUDGE DEWATERING SYSTEM. Supply, installation, testing and commissioning of Screw Type Centrifuge Feed Pump along with control valves, suction and delivery headers and fittings. The capacity will be 2 M3/Hr. per pump @ 40 MWC head (Make-W2P.) (3Q)

2

76500

153000

... More
SLUDGE DEWATERING SYSTEM. Supply, Installation, testing and commissioning of Basket Type Filter Press, MSEP Frame, SS 304 Basket having size 30` dia. (Make-W2P). (3Q)

1

292500

292500

... More
Supply, installation, testing and commissioning of Poly dosing system comprising of: Dosing Pump Capacity: (0-6 LPH) Qty. 2 nos. (1w plus 1s) Make W2P Tank Capacity 250 Ltr Gty I no Make sintex/eqv (3Q)

1

52875

52875

... More
Supply, installation, testing and commissioning of PVC pipe Under Water and MSEP ABOVE Water, all piping of STP and isolation control valves for making the system complete PVC make-Supreme/Prince/Ashirwad MS make- TATA/Zindal/ Eq (3Q)

1

573750

573750

... More
Electricals, Design, fabrication, assembling, wiring, supply, installation testing and commissioning of motor control centre fabricated out of 14 gauge CRCA sheet steel Cable gland plates shall be provided on top as well as at the bottom of the panels Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint 2 Nos earthling terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Panel should be complete with Isolation push button for every equipment and auto manual selection switches (As per actual equipment rating and as per manufacturer standards), Make-W2P Panel Features Energy Meter and VIF Incoming One No. amps TP incoming MCCB complete with the following 0-500 volts 96x96 square mm voltmeter with selector switch and fuses. 0 amps 96x96 square mm ammeter with......./5 amps ratio CT`s and selector switch Phase indicating lamps with toggle switches. Indication lamps for ON/OFF/TRIP status of motors. Outgoing As per STP Equipment Control Panel as described above Supplying and laying of aluminium/copper armored/unarmoured cable of size as per equipment rating along with supports.Supply and fixing of perforated type Gl perforated cable trays with supports, hangers, fastners. (3Q)

1

776812

776812

... More
Supplying, installing, testing and commissioning of treated water boosting pumps CI Head and Base,Cl Impeller along with motor, pressure gauge. NRV on delivery line and mechanical seal. The pump shall be suitable for 400/415 volts, 3 phase 50 cycles AC supply. (1W plus 15). (Make: Wilo/Kirloskar) Capacity/Flow Rate-25.0M3/Hr Head 30 to 35 M 1 Set 2 Nos. pump (1 working plus 1 standby) RPM-2900 MOC-C1 Casing/C.1. or SS Impeller. (3Q)

2

82687

165374

... More
Manpower deputed at site on 8 hours shift basis. (3Q)

180

14253

2565540

... More
Visiting charges of senior engineer twice in a month. (3Q)

120

2767

332040

... More
Consumables like chlorine, oil and grease, EM solution for routine maintenance.(3Q)

60

4612

276720

... More
Test report from NABI, HPCB approved laboratory (3Q)

60

1845

110700

... More
Supply, installation, testing and commissioning of Fine bubble Membrane diffusers of Tube Type of EPDM material for Equalization Tank. (Make: W2P) (3Q)

1

258750

258750



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.