Haryana Police Housing Corporation Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Haryana Police Housing Corporation - HPHC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date30 Jan 2024
Closing Date20 Feb 2024
Tender Amount₹ 23,37,76,079 
Notes
Download

Costs

  • EMD

    ₹ 46,76,000
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 1,180

Summary

Construction Of 96 House (stilt Plus 6 Storeyed I.e 72 Nos. Type Ii And 24 Nos. Type Iii) For Police Official On A Land Measuring 11 Kanal In Police Lines, Ambala City In Front Of Police Dav Public School

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
HSR Item 6.30.1-Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR Rate(Rs.) 156.00 Through Rate

1986.24

309852

156

... More
HSR Item 9.11.1-10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 HSR Rate(Rs.) 488.00 Through Rate

1066.14

520276

488

... More
HSR Item 4.32-Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR Rate(Rs.) 46.00 Through Rate

1016.91

46777

46

... More
HSR Item 15.42-Pile Load Test on single Vertical Pile in accordance with IS:2911(Part-IV) MORTandH clause 1100 (a)Initial and routine load test HSR Rate(Rs.) 754.00 Through Rate

135

101790

754

... More
HSR Item 10.4-Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. HSR Rate(Rs.) 88.00 Through Rate

5172.71

455198

88

... More
HSR Item 6.1.6-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR Rate(Rs.) 2442.00 Through Rate

153.36

374505

2442

... More
HSR Item 6.25.1-Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer- in-charge. 1. All works up to plinth level HSR Rate(Rs.) 4464.00 Through Rate

966.76

4315625

4464

... More
HSR Item 13.3.3.1-Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 3.1. Profile E Fixing with adjustable lugs with split end tail to each jamb HSR Rate(Rs.) 388.00 Through Rate

4921.92

1909704

388

... More
HSR Item 13.3.1.1-Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb HSR Rate(Rs.) 341.00 Through Rate

1478.88

504298

341

... More
HSR Item 12.159.2-Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in- charge . (Cost of aluminium snap beading shall be paid in basic item): 2. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) HSR Rate(Rs.) 922.00 Through Rate

307.04

283090

922

... More
HSR Item 2.B0653- B0653. MS thread rod 8 mm dia with bolt and washer HSR Rate(Rs.) 125.00 Rate

1856.78

232097

125

... More
HSR Item 6.33.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR Rate(Rs.) 61.00 Through Rate

197438.52

12043749

61

... More
HSR Item 28.18-Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer`s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. HSR Rate(Rs.) 322.00 Through Rate

394.2

126932

322

... More
HSR Item 11.17-Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in- charge HSR Rate(Rs.) 234.00 Through Rate

3753.97

878428

234

... More
HSR Item 6.30.3-Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR Rate(Rs.) 208.00 Through Rate

8680.28

1805497

208

... More
HSR Item 6.49.1-Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 1. 50 mm thick HSR Rate(Rs.) 847.00 Through Rate

585.56

495971

847

... More
HSR Item 11.67.1-Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. Water thinnable cement primer HSR Rate(Rs.) 22.00 Through Rate

24477.99

538515

22

... More
HSR Item 10.63.2-Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm HSR Rate(Rs.) 987.00 Through Rate

2916.39

2878478

987

... More
HSR Item 10.61-Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. HSR Rate(Rs.) 756.00 Through Rate

1538.28

1162937

756

... More
HSR Item 6.30.2-Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. HSR Rate(Rs.) 282.00 Through Rate

991.45

279589

282

... More
HSR Item 9.57.2-Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR Rate(Rs.) 200.00 Through Rate

41.13

8226

200

... More
HSR Item 9.58.5.2-Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5° 110 mm bend HSR Rate(Rs.) 93.00 Through Rate

18

1674

93

... More
HSR Item 9.58.5.3-Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5° 150 mm bend HSR Rate(Rs.) 129.00 Through Rate

48

6192

129

... More
HSR Item 12.102.2-Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 100 mm HSR Rate(Rs.) 43.00 Through Rate

1440

61920

43

... More
HSR Item 12.99.5-Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 5. 100x10 mm HSR Rate(Rs.) 46.00 Through Rate

1440

66240

46

... More
HSR Item 12.98.2-Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm HSR Rate(Rs.) 179.00 Through Rate

288

51552

179

... More
HSR Item 12.48.3-Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete : 3. 25 mm dia HSR Rate(Rs.) 409.00 Through Rate

1118.88

457621

409

... More
HSR Item 9.47.2-Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer- in-charge. 2. GI Metal Ceiling Lay in perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. HSR Rate(Rs.) 1031.00 Through Rate

691.2

712627

1031

... More
HSR Item 28.12-`Providing and applying waterproofing treatment to sound, moisture free concrete surface using liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2 mm. It shall be applied in two coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties: 1) Elongation : )400% as per ASTM D 412 2) Tensile Strength : 2.5 N/mm2 as per ASTM D 412 3) Adhesion in-peel test : )50 N as per ASTM C- 836 4) Recovery from 350% elongation : 95% as per ASTM D 412 5) Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr 6) Initial Hardness Shore A : min 60 as per ASTM D 2240 7) Root resistant : protection screed required System includes supply , application and termination of coating all complete as per the manufacturer methodology. Clean the RCC slab/screed surface and wall for treatment by removing dust, dirt and layers of concrete over the surface. etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer’s recommendations. Providing and applying liquid applied single component pitch free polyurethane coating in 2 coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. (Fibre cloth/fleece/reinforcement should not be used in between two coats of PU as it has adverse effect on elongation property and also affects bonding with slab). Termination shall be done 300 mm above vertical wall by providing a groove cut of 30mm x 30mm and seal it with shrinkage compensated polymer modified mortar. Membrane shall be protected using 8mm thick dimple board for protection as per manufacturer`s recommendation followed by backfilling. The rates are inclusive of surface preparation, crack filling, injection grouting at honeycombed areas, coving, priming all complete as per manufacturer methodology but excluding the cost of protection board. ` HSR Rate(Rs.) 719.00 Through Rate

335.68

241353

719

... More
HSR Item 28.30-Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. HSR Rate(Rs.) 461.00 Through Rate

33.18

15295

461

... More
HSR Item 28.29.2-Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled and honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystalline mortar shall conform to the EN 1504-3 having compressive strength Class R4 =45 MPa and adhesive bond strength Class R3 =1.5 MPa. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. 2. For patching of tie rod holes, prepared tie rod hole surface and then primed the area with integral crystalline slurry @0.070kg/sqm and while the surface is tacky repair and then filled the tie rod holes with crystalline mortar@0.040kg per hole. The crystalline mortar should be tightly rodded into tie rod holes or packed tightly (For 25x25x25 mm tie rod hole, use 0.040kg to fill the hole) HSR Rate(Rs.) 13.00 Through Rate

150

1950

13

... More
HSR Item 28.20.2-Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 2. For horizontal surface one coat @1.10 kg per sqm HSR Rate(Rs.) 311.00 Through Rate

22.39

6964

311

... More
HSR Item 11.76-Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR Rate(Rs.) 37.00 Through Rate

3700.73

136927

37

... More
HSR Item 6.30.5-Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR Rate(Rs.) 296.00 Through Rate

7114.04

2105755

296

... More
HSR Item 6.25.2-Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer- in-charge. 2. All works above plinth level up to floor IV level HSR Rate(Rs.) 4502.00 Through Rate

3226.51

14525766

4502

... More
HSR Item 12.37.1-Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws HSR Rate(Rs.) 1400.00 Through Rate

894.09

1251724

1400

... More
HSR Item 7.22.2-Brick work with common burnt clay non- modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) HSR Rate(Rs.) 3961.00 Through Rate

818.2

3240870

3961

... More
HSR Item 11.6.1-15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 102.00 Through Rate

733.52

74818

102

... More
HSR Item 11.65.1-Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer`s specification. 1. Two or more coats on new work HSR Rate(Rs.) 31.00 Through Rate

24477.99

758817

31

... More
HSR Item 12.157.2.2-Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) HSR Rate(Rs.) 403.00 Through Rate

13127.14

5290235

403

... More
HSR Item 11.4.2-10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR Rate(Rs.) 86.00 Through Rate

7824.95

672945

86

... More
HSR Item 12.157.1.2-Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) HSR Rate(Rs.) 350.00 Through Rate

2418.19

846366

350

... More
HSR Item 6.30.13-Centering and shuttering including strutting, propping etc. and removal of form for 13. Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards HSR Rate(Rs.) 458.00 Through Rate

1263.63

578740

458

... More
HSR Item 6.30.6-Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts HSR Rate(Rs.) 262.00 Through Rate

6910.84

1810639

262

... More
HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 84.00 Through Rate

19571.74

1644026

84

... More
HSR Item 13.3.2.1-Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 2.1. Profile C Fixing with adjustable lugs with split end tail to each jamb HSR Rate(Rs.) 364.00 Through Rate

2460.96

895789

364

... More
HSR Item 7.28.2-Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) HSR Rate(Rs.) 488.00 Through Rate

5896.09

2877290

488

... More
HSR Item 12.102.1-Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm HSR Rate(Rs.) 49.00 Through Rate

864

42336

49

... More
HSR Item 11.60-Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR Rate(Rs.) 59.00 Through Rate

44783.25

2642211

59

... More
HSR Item 11.98.1-Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 1. New work (Two or more coats applied @ 1.43 litre/ 10 sqm Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm HSR Rate(Rs.) 86.00 Through Rate

20305.26

1746252

86

... More
HSR Item 12.37.3-Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 3. 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws HSR Rate(Rs.) 1316.00 Through Rate

647.88

852615

1316

... More
HSR Item 28.17.1-Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 1. With average thickness of 120 mm and minimum thickness at khurra as 65 mm. HSR Rate(Rs.) 664.00 Through Rate

692.84

460047

664

... More
HSR Item 12.33.2-Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 2. With 12 mm mild steel U beading HSR Rate(Rs.) 697.00 Through Rate

804.6

560805

697

... More
HSR Item 10.62-Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. HSR Rate(Rs.) 570.00 Through Rate

4906.44

2796670

570

... More
HSR Item 10.70.2-Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 2. Size of Tile 600x600 mm HSR Rate(Rs.) 140.00 Through Rate

4038.85

565438

140

... More
HSR Item 10.50.1-Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in- Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. HSR Rate(Rs.) 2707.00 Through Rate

226.8

613947

2707

... More
HSR Item 10.67.2-Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 2. Size of Tile 600x600 mm HSR Rate(Rs.) 1004.00 Through Rate

1122.46

1126944

1004

... More
HSR Item 10.51-Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. HSR Rate(Rs.) 2534.00 Through Rate

124.74

316091

2534

... More
HSR Item 12.158.2-Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 2. Pre-laminated particle board with decorative lamination on both sides HSR Rate(Rs.) 789.00 Through Rate

92.49

72976

789

... More
HSR Item 13.10.1-Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1. 4.0 mm thick glass panes HSR Rate(Rs.) 539.00 Through Rate

667.88

359986

539

... More
HSR Item 7.58-Dressed or moulded one brick cornice laid in cement sand mortar 1:4 including 12 mm thick cement plaster 1:4 or pointing, as required. HSR Rate(Rs.) 75.00 Through Rate

415.71

31178

75

... More
HSR Item 11.5.4-12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand) HSR Rate(Rs.) 68.00 Through Rate

15015.86

1021078

68

... More
HSR Item 11.6.2-15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) HSR Rate(Rs.) 86.00 Through Rate

1637.18

140797

86

... More
HSR Item 6.30.4-Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) HSR Rate(Rs.) 223.00 Through Rate

493.13

109967

223

... More
HSR Item 6.30.7-Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases HSR Rate(Rs.) 290.00 Through Rate

496.39

143954

290

... More
HSR Item 11.77-Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR Rate(Rs.) 19.00 Through Rate

3700.73

70313

19

... More
HSR Item 11.68.3-Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works HSR Rate(Rs.) 19.00 Through Rate

3410.59

64801

19

... More
HSR Item 11.82.1-Painting the wooden / metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work HSR Rate(Rs.) 49.00 Through Rate

7111.32

348454

49

... More
HSR Item 12.42-Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). HSR Rate(Rs.) 81.00 Through Rate

1554.92

125948

81

... More
HSR Item 12.89-Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR Rate(Rs.) 701.00 Through Rate

216

151416

701

... More
HSR Item 12.99.3-Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm HSR Rate(Rs.) 72.00 Through Rate

720

51840

72

... More
HSR Item 12.99.4-Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 4. 150x10 mm HSR Rate(Rs.) 62.00 Through Rate

2160

133920

62

... More
HSR Item 12.103.2-Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 2. Twin rubber stopper HSR Rate(Rs.) 52.00 Through Rate

720

37440

52

... More
HSR Item 12.98.1-Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm HSR Rate(Rs.) 201.00 Through Rate

504

101304

201

... More
HSR Item 4.14.1-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. HSR Rate(Rs.) 83.00 Through Rate

1016.91

84403

83

... More
HSR Item 12.48.2-Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete : 2. 20 mm dia HSR Rate(Rs.) 316.00 Through Rate

198.72

62795

316

... More
HSR Item 13.29.2-Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR Rate(Rs.) 83.00 Through Rate

31458.18

2611028

83

... More
HSR Item 6.1.1-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) HSR Rate(Rs.) 3975.00 Through Rate

397.44

1579824

3975

... More
HSR Item 7.51-Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). HSR Rate(Rs.) 3613.00 Through Rate

1399

5054576

3613

... More
HSR Item 10.48-Providing and laying Baroda Green marble stone 17mm and above thick flooring included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR Rate(Rs.) 1187.00 Through Rate

1578.83

1874073

1187

... More
HSR Item 10.47-Providing and laying Baroda Green marble stone 17mm and above thick in risers of step, skirting , dado, pillars and wall lining included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR Rate(Rs.) 1214.00 Through Rate

380.44

461856

1214

... More
HSR Item 6.34.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR Rate(Rs.) 61.00 Through Rate

296613.48

18093422

61

... More
HSR Item 7.97-30 mm red sand stone sun-shade (chisel- dressed) supported on red sand stone brackets, fixed in walls with cement mortar 1:4 (1 cement : 4 coarse sand), including finishing complete. HSR Rate(Rs.) 510.00 Through Rate

524.16

267321

510

... More
HSR Item 2.PH230- PH230. Core cutting up to 200mm RCC slab - 125mm dia HSR Rate(Rs.) 625.00 Rate

345

215625

625

... More
HSR Item 9.57.3-Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter HSR Rate(Rs.) 269.00 Through Rate

615.6

165596

269

... More
HSR Item 6.66-Extra for laying reinforced cement concrete in or under water and/ or liquid mud, including cost of pumping or bailing out water and removing slush etc., complete. HSR Rate(Rs.) 360.00 Material Rate

799.4

287785

360

... More
HSR Item 6.27-Extra for R.C.C./ B.M.C/ R.M.C. work above floor IV level for each three floors or part thereof. HSR Rate(Rs.) 244.00 Through Rate

1898.84

463317

244

... More
HSR Item 6.65-Extra for laying concrete in or under foul positions. HSR Rate(Rs.) 157.00 Through Rate

84.04

13194

157

... More
NS Item -PROTECTION DRAIN BOARD : Providing and fixing Drain board of branded organization as protection board for waterproofing which is high strength one side dimpled structure, light in weight 400 ( plus /- 20) gm/sqm yet flexible strong and resilient. Product should be High Density Polyethylene (HDPE) draining system with 8 mm dimples, which helps in fast and efficient drainage of surp us water and controls soil erosion,protects construction, allows water to drain while reducing water table pressure. It is mainly used for,vertical/ horizontal drainage, soil erosion control,and prctects the main waterproofing layer complete as per direction of engineer incharge.

60.06

20298

338

... More
NS Item -Boring with hydraulic pilling rigs with power units/DMC, Providing and Installing cast in Situ single under reemed piles of 500 mm dia and Length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solutions and the length of pile to be embedded in pile cap and including preparation of pile head by dismantling extra loose concrete etc. all complete.. Note:- 1. Length of Pile for payment shall be measured upto the bottom of pile cap 2. No Extra Payment will be made on account of liquid Mud/Daldal removal occured during boring/piling 3. Design mix for Pile shall be prepared from authorized laboratory by the agency. No any payment will be made on account of Extra cement.

4465.44

8560248

1917

... More
Sub-Component Total Amount (A)

-

-

-

... More
Sub-Component: Type-II 72 Nos (Public Health)

-

-

-

... More
HSR Item 21.38.4-`Lowering salt glazed stoneware pipes and specials into trenches for all depths and laying out the same to correct alignment gradient, level etc in trenches including all dressing and trimming of bed and sides of trenches, if required, trimming and cutting of concrete beds and joint holes, supporting the pipes and specials, in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching hunching and envelopes are completed. The sewer shall rest on the bed at every point throughout its length and to ensure this, it shall be grouted in without extra charge by the contractor with lime surkhi mortar, in the case of lime concrete beds and 1:3 cement sand mortar in the case of cement concrete beds including cartage from Divisional Store or nearest Railway station to site of work. The internal diameter of sewer being :-` 4. 200 mm internal diameter of sewer HSR Rate(Rs.) 493.00 Through Rate

71.5

35251

493

... More
HSR Item 21.93.2-Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening HSR Rate(Rs.) 1058.00 Through Rate

44

46552

1058

... More
HSR Item 20.26.1-Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 1. 11.43 cm thick wall HSR Rate(Rs.) 164.00 Through Rate

231

37884

164

... More
HSR Item 22.14.1.1-Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 1.1. Semi rigid pipe 32 mm dia HSR Rate(Rs.) 46.00 Through Rate

432

19872

46

... More
HSR Item 22.33-Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. HSR Rate(Rs.) 10809.00 Through Rate

72

778248

10809

... More
HSR Item 22.86.1-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes HSR Rate(Rs.) 205.00 Through Rate

720

147600

205

... More
HSR Item 22.20.2-Providing and fixing in position C.I. plain Nahani Trap conforming to I.S.I. specifications and of self cleaning design with C.P. brass hinged grating with frame complete 2. With 75 mm internal diameter outlet HSR Rate(Rs.) 1170.00 Through Rate

432

505440

1170

... More
HSR Item 22.85.2-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR Rate(Rs.) 181.00 Through Rate

180

32580

181

... More
HSR Item 22.38-Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. HSR Rate(Rs.) 241.00 Through Rate

72

17352

241

... More
HSR Item 22.86.2-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR Rate(Rs.) 264.00 Through Rate

2042.64

539256

264

... More
HSR Item 20.66.1-Cutting DI pipe and chipping or filling the surface to a uniform finish 1. 100 mm i/d HSR Rate(Rs.) 22.00 Through Rate

40

880

22

... More
HSR Item 22.85.3-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR Rate(Rs.) 233.00 Through Rate

5399.52

1258088

233

... More
HSR Item 20.64.1-Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade SandS pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/W to be measured and paid separately. 1. 100 mm i/d HSR Rate(Rs.) 839.00 Through Rate

666.84

559478

839

... More
HSR Item 20.67.1-Joining DI socketed pipes, valves and special with rubber tyton joints fitted complete including cost of labour and tools etc. and tested complete. 1. 100 mm i/d HSR Rate(Rs.) 29.00 Through Rate

170

4930

29

... More
HSR Item 22.162.1.1-Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 1.1. 100 mm diameter Class I HSR Rate(Rs.) 5044.00 Through Rate

4

20176

5044

... More
HSR Item 20.56.2-Providing and screwing in brass/Gun Metal ferrules drilling and tapping Cast Iron /D.I. /G.I. pipe lines of all diameters and connections including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in- Charge. (Excavation will be paid separately). 2. 10mm i/d ferrule HSR Rate(Rs.) 155.00 Through Rate

72

11160

155

... More
HSR Item 22.101.1.1-Providing and fixing Unplasticised PVC connection pipe with brass unions : 1.1. 30 cm length 15 mm nominal bore HSR Rate(Rs.) 44.00 Through Rate

504

22176

44

... More
HSR Item 22.98.1-Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore HSR Rate(Rs.) 414.00 Through Rate

144

59616

414

... More
HSR Item 22.104.1-Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore HSR Rate(Rs.) 346.00 Through Rate

144

49824

346

... More
HSR Item 6.30.1-Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR Rate(Rs.) 156.00 Through Rate

652.54

101795

156

... More
HSR Item 4.16.1.2-Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1.2. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia HSR Rate(Rs.) 62.00 Through Rate

725.04

44952

62

... More
HSR Item 21.38.2-`Lowering salt glazed stoneware pipes and specials into trenches for all depths and laying out the same to correct alignment gradient, level etc in trenches including all dressing and trimming of bed and sides of trenches, if required, trimming and cutting of concrete beds and joint holes, supporting the pipes and specials, in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching hunching and envelopes are completed. The sewer shall rest on the bed at every point throughout its length and to ensure this, it shall be grouted in without extra charge by the contractor with lime surkhi mortar, in the case of lime concrete beds and 1:3 cement sand mortar in the case of cement concrete beds including cartage from Divisional Store or nearest Railway station to site of work. The internal diameter of sewer being :-` 2. 150 mm internal diameter of sewer HSR Rate(Rs.) 380.00 Through Rate

30

11400

380

... More
HSR Item 21.39.4-Jointing and fixing salt glazed stoneware pipes and special in trenches using cement sand mortar 1:1 and best white Italian tarred hemp/yarn including finishing and trowel ling of each joint at an angle of 45 degrees with the longitudinal axis of the pipes, watering, keeping the joints covered and wetted till the same are cured, testing the sewer lines for leakages and making all leakages and defect good, complete as laid down in the contract specifications. 4. 200 mm internal diametre of sewer HSR Rate(Rs.) 75.00 Through Rate

1008

75600

75

... More
HSR Item 21.39.2-Jointing and fixing salt glazed stoneware pipes and special in trenches using cement sand mortar 1:1 and best white Italian tarred hemp/yarn including finishing and trowel ling of each joint at an angle of 45 degrees with the longitudinal axis of the pipes, watering, keeping the joints covered and wetted till the same are cured, testing the sewer lines for leakages and making all leakages and defect good, complete as laid down in the contract specifications. 2. 150 mm internal diametre of sewer HSR Rate(Rs.) 57.00 Through Rate

204

11628

57

... More
HSR Item 22.1.3-Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 3. White vitreous chinaware Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps HSR Rate(Rs.) 1818.00 Through Rate

144

261792

1818

... More
HSR Item 22.5-Providing and fixing white vitreous chinaware pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. HSR Rate(Rs.) 1104.00 Through Rate

144

158976

1104

... More
HSR Item 9.60-Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. HSR Rate(Rs.) 35.00 Through Rate

111

3885

35

... More
HSR Item 21.40.4-Cutting glazed stoneware pipes and specials chipping and finishing the cut surface to a uniform finish and roughing the part of the pipes, if any entering the sockets of the adjacent pipes complete, to the satisfaction of the engineer-in-charge of the works. 4. 200 mm internal diametre of pipes HSR Rate(Rs.) 28.00 Through Rate

136

3808

28

... More
HSR Item 21.40.2-Cutting glazed stoneware pipes and specials chipping and finishing the cut surface to a uniform finish and roughing the part of the pipes, if any entering the sockets of the adjacent pipes complete, to the satisfaction of the engineer-in-charge of the works. 2. 150 mm internal diametre of pipes HSR Rate(Rs.) 21.00 Through Rate

68

1428

21

... More
HSR Item 21.90.4.2-Construction of rectangular standard brick masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular pipe sewers up to the required depth in 1.5 cement sand mortar, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium silicate on interior surface where required, reinforced cement concrete slab 180mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. the rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. sodium silicate shall be supplied free of cost at the stores of the Engineer-in- charge. 4.2. On 200 mm internal diameter pipe sewer - for 2.10 meters depth below ground level HSR Rate(Rs.) 15474.00 Through Rate

2

30948

15474

... More
HSR Item 22.166.1.1-Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.1. 100x100 mm size P type With common burnt clay non-modular bricks of class designation 7.5 HSR Rate(Rs.) 1457.00 Through Rate

48

69936

1457

... More
HSR Item 6.1.8-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 8. 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) HSR Rate(Rs.) 2165.00 Through Rate

65.25

141274

2165

... More
HSR Item 20.26.2-Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wall HSR Rate(Rs.) 242.00 Through Rate

252

60984

242

... More
HSR Item 22.98.2-Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore HSR Rate(Rs.) 384.00 Through Rate

6

2304

384

... More
HSR Item 22.102.2-Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 2. 150 mm diameter HSR Rate(Rs.) 151.00 Through Rate

144

21744

151

... More
HSR Item 22.107.1-Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore HSR Rate(Rs.) 508.00 Through Rate

1008

512064

508

... More
HSR Item 22.109-Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR Rate(Rs.) 49.00 Through Rate

936

45864

49

... More
HSR Item 21.84.3-Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR Rate(Rs.) 5438.00 Through Rate

44

239272

5438

... More
HSR Item 22.222.2.2-Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete HSR Rate(Rs.) 322.00 Through Rate

1346.16

433463

322

... More
HSR Item 21.85.3-Extra for every 0.30 metre depth of Inspection chamber 3. 600 mm x 900 mm inside HSR Rate(Rs.) 1138.00 Through Rate

44

50072

1138

... More
HSR Item 22.222.2.3-Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete HSR Rate(Rs.) 273.00 Through Rate

1572

429156

273

... More
HSR Item 6.1.3-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 3. 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) HSR Rate(Rs.) 3426.00 Through Rate

146.82

503008

3426

... More
HSR Item 22.181-Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR Rate(Rs.) 7.00 Through Rate

72000

504000

7

... More
HSR Item 20.68.1-Providing, lowering, laying in trenches, aligning, fixing in position and jointing at all level/depths Ductile Iron (DI) standard specials plain /flanged/ socketed confirming to IS9523-2000 with rubber ring (EPDM/SBR) joints such as tees, bends, tapers, caps etc. with in trenches in DI pipe line complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. 1. Up to 300mm dia HSR Rate(Rs.) 64.00 Through Rate

1000

64000

64

... More
HSR Item 22.8.2-Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). 2. Two way HSR Rate(Rs.) 2475.00 Through Rate

144

356400

2475

... More
HSR Item 22.10.1.2-Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1.2. Kitchen sink with drain board 510x1040 mm bowl depth 225 mm HSR Rate(Rs.) 4322.00 Through Rate

72

311184

4322

... More
HSR Item 28.14-Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). HSR Rate(Rs.) 375.00 Through Rate

450.43

168912

375

... More
HSR Item 22.22.1-Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1. White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests HSR Rate(Rs.) 3493.00 Through Rate

72

251496

3493

... More
HSR Item 22.105.1-Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore HSR Rate(Rs.) 512.00 Through Rate

648

331776

512

... More
NS Item -Providing and fixing CP jali/grating 100 mm with hinges complete in all respects.

432

64368

149

... More
NS Item -Providing and fixing Towel Ring round with round flange of Jaquar make (ACN-1121BN) or equivalent approved brand complete in all respects to the satisfection of engineer in charge.

144

136512

948

... More
HSR Item 22.209-Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. HSR Rate(Rs.) 813.00 Through Rate

288

234144

813

... More
NS Item -`SITC of Ball valves with and without strainers alongwith fittings etc of sizes:` 32 mm dia without Strainer Make : RC/Anergy/Advance

144

183024

1271

... More
NS Item -`SITC of Ball valves with and without strainers alongwith fittings etc of sizes:` 25 mm dia without Strainer Make : RC/Anergy/Advance

144

121968

847

... More
NS Item -Providing and fixing CPVC Ball valve of 20 mm dia including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge.

144

19584

136

... More
NS Item -Providing and fixing CPVC tank connector/ tank nipple 20 mm dia including cutting hole and Jointing the pipe in water tank with solution etc. complete in all respects as per direction of engineer incharge

144

7200

50

... More
NS Item -Providing and fixing CPVC tank connector/ tank nipple 25 mm including cutting hole and Jointing the pipe in water tank with solution etc. complete in all respects as per direction of engineer incharge

144

20592

143

... More
NS Item -Providing and fixing 32mm dia CPVC Union in CPVC pipe including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge

144

43920

305

... More
NS Item -Providing and fixing 25mm CPVC Union in CPVC pipe including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge .

432

92448

214

... More
NS Item -Providing and fixing 20 mm CPVC Union in CPVC pipe including cutting and Jointing the pipe with solution etc. complete

432

50544

117

... More
HSR Item 22.103.3-Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore HSR Rate(Rs.) 292.00 Through Rate

72

21024

292

... More
HSR Item 2.B1332- B1332. Soap Dish HSR Rate(Rs.) 445.00 Rate

288

128160

445

... More
HSR Item 2.B1505- B1505. PTMT - Towel Rail (600 mm long) HSR Rate(Rs.) 147.00 Rate

144

21168

147

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia Single Tee with door

240

52080

217

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia Single Tee

72

13464

187

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 90 mm dia . Single Tee with Door

246

45264

184

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 90 mm dia . Single Tee

72

11304

157

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 90 mm dia . Bend 87.5 degree

240

27360

114

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia Bend 87.5 degree

240

35040

146

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 90 mm dia . Vent Cowl

120

4200

35

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia Vent Cowl

120

4800

40

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia . Nahani Trap without Jali (110x90) mm

216

40824

189

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia Nahani Trap without Jali (110x110) mm

360

77760

216

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia . P-Trap

144

56736

394

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 90 mm dia . Coupler

192

16128

84

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia Coupler

192

19776

103

... More
NS Item -Providing and Fixing Powder Coated aluminum I- Hook 150mm Long Included Labour for fixing complete in all respect.

864

26784

31

... More
Sub-Component Total Amount (B)

-

-

-

... More
Sub-Component :- Type-III 24 Nos (Civil Work)

-

-

-

... More
HSR Item 13.29.2-Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR Rate(Rs.) 83.00 Through Rate

12443.58

1032817

83

... More
HSR Item 11.6.1-15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 102.00 Through Rate

746.23

76115

102

... More
HSR Item 9.57.3-Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter HSR Rate(Rs.) 269.00 Through Rate

180.4

48527

269

... More
HSR Item 11.5.4-12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand) HSR Rate(Rs.) 68.00 Through Rate

6139.83

417508

68

... More
HSR Item 6.30.4-Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ) HSR Rate(Rs.) 223.00 Through Rate

228.14

50876

223

... More
HSR Item 15.42-Pile Load Test on single Vertical Pile in accordance with IS:2911(Part-IV) MORTandH clause 1100 (a)Initial and routine load test HSR Rate(Rs.) 754.00 Through Rate

135

101790

754

... More
HSR Item 2.B0653- B0653. MS thread rod 8 mm dia with bolt and washer HSR Rate(Rs.) 125.00 Rate

592.83

74103

125

... More
HSR Item 10.61-Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. HSR Rate(Rs.) 756.00 Through Rate

519.52

392754

756

... More
HSR Item 6.30.3-Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR Rate(Rs.) 208.00 Through Rate

3651.94

759604

208

... More
HSR Item 6.30.2-Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. HSR Rate(Rs.) 282.00 Through Rate

578.98

163271

282

... More
HSR Item 10.63.2-Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm HSR Rate(Rs.) 987.00 Through Rate

1037.02

1023539

987

... More
HSR Item 11.68.3-Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works HSR Rate(Rs.) 19.00 Through Rate

1373.62

26098

19

... More
HSR Item 11.60-Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR Rate(Rs.) 59.00 Through Rate

13900.5

820129

59

... More
HSR Item 11.65.1-Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer`s specification. 1. Two or more coats on new work HSR Rate(Rs.) 31.00 Through Rate

8201.74

254253

31

... More
HSR Item 6.33.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR Rate(Rs.) 61.00 Through Rate

66555.12

4059862

61

... More
HSR Item 4.32-Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR Rate(Rs.) 46.00 Through Rate

287.38

13219

46

... More
HSR Item 28.30-Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. HSR Rate(Rs.) 461.00 Through Rate

10.92

5034

461

... More
HSR Item 28.29.2-Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled and honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystalline mortar shall conform to the EN 1504-3 having compressive strength Class R4 =45 MPa and adhesive bond strength Class R3 =1.5 MPa. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. 2. For patching of tie rod holes, prepared tie rod hole surface and then primed the area with integral crystalline slurry @0.070kg/sqm and while the surface is tacky repair and then filled the tie rod holes with crystalline mortar@0.040kg per hole. The crystalline mortar should be tightly rodded into tie rod holes or packed tightly (For 25x25x25 mm tie rod hole, use 0.040kg to fill the hole) HSR Rate(Rs.) 13.00 Through Rate

50

650

13

... More
HSR Item 4.14.1-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. HSR Rate(Rs.) 83.00 Through Rate

287.38

23852

83

... More
HSR Item 10.62-Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. HSR Rate(Rs.) 570.00 Through Rate

1584.82

903345

570

... More
HSR Item 10.50.1-Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in- Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. HSR Rate(Rs.) 2707.00 Through Rate

133.63

361741

2707

... More
HSR Item 10.51-Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. HSR Rate(Rs.) 2534.00 Through Rate

22.27

56437

2534

... More
HSR Item 10.47-Providing and laying Baroda Green marble stone 17mm and above thick in risers of step, skirting , dado, pillars and wall lining included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR Rate(Rs.) 1214.00 Through Rate

62.83

76269

1214

... More
HSR Item 10.37.1-Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick HSR Rate(Rs.) 790.00 Through Rate

246.31

194586

790

... More
HSR Item 10.38-Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. HSR Rate(Rs.) 836.00 Through Rate

29.19

24402

836

... More
HSR Item 13.3.3.1-Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 3.1. Profile E Fixing with adjustable lugs with split end tail to each jamb HSR Rate(Rs.) 388.00 Through Rate

2067.84

802321

388

... More
HSR Item 13.3.2.1-Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 2.1. Profile C Fixing with adjustable lugs with split end tail to each jamb HSR Rate(Rs.) 364.00 Through Rate

769.92

280250

364

... More
HSR Item 6.30.1-Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR Rate(Rs.) 156.00 Through Rate

626.82

97784

156

... More
HSR Item 10.67.2-Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 2. Size of Tile 600x600 mm HSR Rate(Rs.) 1004.00 Through Rate

134.01

134548

1004

... More
HSR Item 10.70.2-Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 2. Size of Tile 600x600 mm HSR Rate(Rs.) 140.00 Through Rate

1171.03

163944

140

... More
HSR Item 9.11.1-10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 HSR Rate(Rs.) 488.00 Through Rate

500.76

244372

488

... More
HSR Item 9.17.1-Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase HSR Rate(Rs.) 112.00 Through Rate

333.31

37330

112

... More
HSR Item 12.102.2-Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 100 mm HSR Rate(Rs.) 43.00 Through Rate

384

16512

43

... More
HSR Item 12.98.1-Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm HSR Rate(Rs.) 201.00 Through Rate

288

57888

201

... More
HSR Item 12.98.2-Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm HSR Rate(Rs.) 179.00 Through Rate

96

17184

179

... More
HSR Item 7.22.2-Brick work with common burnt clay non- modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) HSR Rate(Rs.) 3961.00 Through Rate

248.95

986090

3961

... More
HSR Item 9.58.5.3-Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5° 150 mm bend HSR Rate(Rs.) 129.00 Through Rate

16

2064

129

... More
HSR Item 9.57.2-Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter HSR Rate(Rs.) 200.00 Through Rate

10.95

2190

200

... More
HSR Item 9.58.5.2-Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5° 110 mm bend HSR Rate(Rs.) 93.00 Through Rate

6

558

93

... More
HSR Item 9.58.3.1-Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 3.1. Single tee with door 75x75x75 mm HSR Rate(Rs.) 104.00 Through Rate

24

2496

104

... More
HSR Item 11.17-Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in- charge HSR Rate(Rs.) 234.00 Through Rate

1534.95

359178

234

... More
HSR Item 2.PH230- PH230. Core cutting up to 200mm RCC slab - 125mm dia HSR Rate(Rs.) 625.00 Rate

115

71875

625

... More
HSR Item 9.47.2-Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer- in-charge. 2. GI Metal Ceiling Lay in perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. HSR Rate(Rs.) 1031.00 Through Rate

178.92

184466

1031

... More
HSR Item 28.18-Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer`s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. HSR Rate(Rs.) 322.00 Through Rate

133.4

42954

322

... More
HSR Item 28.20.2-Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 2. For horizontal surface one coat @1.10 kg per sqm HSR Rate(Rs.) 311.00 Through Rate

7.31

2273

311

... More
HSR Item 28.17.1-Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 1. With average thickness of 120 mm and minimum thickness at khurra as 65 mm. HSR Rate(Rs.) 664.00 Through Rate

230.95

153348

664

... More
HSR Item 6.1.1-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) HSR Rate(Rs.) 3975.00 Through Rate

131.42

522402

3975

... More
HSR Item 28.12-`Providing and applying waterproofing treatment to sound, moisture free concrete surface using liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2 mm. It shall be applied in two coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties: 1) Elongation : )400% as per ASTM D 412 2) Tensile Strength : 2.5 N/mm2 as per ASTM D 412 3) Adhesion in-peel test : )50 N as per ASTM C- 836 4) Recovery from 350% elongation : 95% as per ASTM D 412 5) Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr 6) Initial Hardness Shore A : min 60 as per ASTM D 2240 7) Root resistant : protection screed required System includes supply , application and termination of coating all complete as per the manufacturer methodology. Clean the RCC slab/screed surface and wall for treatment by removing dust, dirt and layers of concrete over the surface. etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer’s recommendations. Providing and applying liquid applied single component pitch free polyurethane coating in 2 coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. (Fibre cloth/fleece/reinforcement should not be used in between two coats of PU as it has adverse effect on elongation property and also affects bonding with slab). Termination shall be done 300 mm above vertical wall by providing a groove cut of 30mm x 30mm and seal it with shrinkage compensated polymer modified mortar. Membrane shall be protected using 8mm thick dimple board for protection as per manufacturer`s recommendation followed by backfilling. The rates are inclusive of surface preparation, crack filling, injection grouting at honeycombed areas, coving, priming all complete as per manufacturer methodology but excluding the cost of protection board. ` HSR Rate(Rs.) 719.00 Through Rate

101.99

73332

719

... More
HSR Item 6.25.1-Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer- in-charge. 1. All works up to plinth level HSR Rate(Rs.) 4464.00 Through Rate

324.69

1449425

4464

... More
HSR Item 6.25.2-Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer- in-charge. 2. All works above plinth level up to floor IV level HSR Rate(Rs.) 4502.00 Through Rate

1012.97

4560395

4502

... More
HSR Item 12.157.2.2-Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) HSR Rate(Rs.) 403.00 Through Rate

5142.24

2072322

403

... More
HSR Item 7.51-Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). HSR Rate(Rs.) 3613.00 Through Rate

462.61

1671402

3613

... More
HSR Item 6.1.6-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR Rate(Rs.) 2442.00 Through Rate

82.16

200644

2442

... More
HSR Item 10.48-Providing and laying Baroda Green marble stone 17mm and above thick flooring included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1:3 and jointed with white slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. HSR Rate(Rs.) 1187.00 Through Rate

474.67

563436

1187

... More
HSR Item 6.34.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR Rate(Rs.) 61.00 Through Rate

155314.97

9474213

61

... More
HSR Item 12.48.3-Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete : 3. 25 mm dia HSR Rate(Rs.) 409.00 Through Rate

280.8

114847

409

... More
HSR Item 6.30.5-Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR Rate(Rs.) 296.00 Through Rate

2753.29

814974

296

... More
HSR Item 6.30.6-Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts HSR Rate(Rs.) 262.00 Through Rate

2114.96

554119

262

... More
HSR Item 6.30.7-Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases HSR Rate(Rs.) 290.00 Through Rate

177.75

51548

290

... More
HSR Item 6.30.13-Centering and shuttering including strutting, propping etc. and removal of form for 13. Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards HSR Rate(Rs.) 458.00 Through Rate

429.43

196677

458

... More
HSR Item 9.58.5.1-Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.1. Bend 87.5° 75 mm bend HSR Rate(Rs.) 59.00 Through Rate

8

472

59

... More
HSR Item 11.82.1-Painting the wooden / metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work HSR Rate(Rs.) 49.00 Through Rate

1885.08

92368

49

... More
HSR Item 12.42-Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). HSR Rate(Rs.) 81.00 Through Rate

245.71

19902

81

... More
HSR Item 12.89-Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR Rate(Rs.) 701.00 Through Rate

72

50472

701

... More
HSR Item 9.10.1-Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 1. With residual type petroleum bitumen of grade VG -10 HSR Rate(Rs.) 93.00 Through Rate

500.76

46570

93

... More
HSR Item 10.4-Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. HSR Rate(Rs.) 88.00 Through Rate

2251.57

198138

88

... More
HSR Item 12.103.2-Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 2. Twin rubber stopper HSR Rate(Rs.) 52.00 Through Rate

288

14976

52

... More
HSR Item 12.157.1.2-Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) HSR Rate(Rs.) 350.00 Through Rate

1329.74

465409

350

... More
HSR Item 12.33.2-Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 2. With 12 mm mild steel U beading HSR Rate(Rs.) 697.00 Through Rate

310.47

216399

697

... More
HSR Item 12.158.2-Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 2. Pre-laminated particle board with decorative lamination on both sides HSR Rate(Rs.) 789.00 Through Rate

30.83

24325

789

... More
HSR Item 13.10.1-Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1. 4.0 mm thick glass panes HSR Rate(Rs.) 539.00 Through Rate

172.93

93207

539

... More
HSR Item 6.49.1-Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 1. 50 mm thick HSR Rate(Rs.) 847.00 Through Rate

195.19

165324

847

... More
HSR Item 12.48.2-Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete : 2. 20 mm dia HSR Rate(Rs.) 316.00 Through Rate

56.4

17822

316

... More
HSR Item 12.37.1-Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws HSR Rate(Rs.) 1400.00 Through Rate

391.58

548209

1400

... More
HSR Item 8.1.1.1-Providing and fixing dry cladding up to 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size up to 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 1.1. Red sand stone - 30mm thick gang saw cut stone HSR Rate(Rs.) 1006.00 Through Rate

164.63

165617

1006

... More
HSR Item 12.37.3-Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 3. 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws HSR Rate(Rs.) 1316.00 Through Rate

245.71

323347

1316

... More
HSR Item 11.76-Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. HSR Rate(Rs.) 37.00 Through Rate

1529.47

56590

37

... More
HSR Item 11.77-Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. HSR Rate(Rs.) 19.00 Through Rate

1529.47

29059

19

... More
HSR Item 7.28.2-Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) HSR Rate(Rs.) 488.00 Through Rate

2244.84

1095481

488

... More
HSR Item 11.4.2-10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) HSR Rate(Rs.) 86.00 Through Rate

2061.91

177323

86

... More
HSR Item 10.104-Mirror polishing on marble work/Granite work/stone work whereever reqired to give high gloss finish complete. HSR Rate(Rs.) 257.00 Through Rate

275.5

70804

257

... More
HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 84.00 Through Rate

4952.53

416012

84

... More
HSR Item 9.57.1-Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1. 75 mm diameter HSR Rate(Rs.) 121.00 Through Rate

90.2

10914

121

... More
HSR Item 12.159.2-Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in- charge . (Cost of aluminium snap beading shall be paid in basic item): 2. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) HSR Rate(Rs.) 922.00 Through Rate

84.91

78290

922

... More
HSR Item 12.99.3-Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm HSR Rate(Rs.) 72.00 Through Rate

528

38016

72

... More
HSR Item 12.99.5-Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 5. 100x10 mm HSR Rate(Rs.) 46.00 Through Rate

384

17664

46

... More
HSR Item 12.102.1-Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm HSR Rate(Rs.) 49.00 Through Rate

1104

54096

49

... More
HSR Item 12.99.4-Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 4. 150x10 mm HSR Rate(Rs.) 62.00 Through Rate

288

17856

62

... More
HSR Item 13.3.1.1-Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb HSR Rate(Rs.) 341.00 Through Rate

876.48

298879

341

... More
HSR Item 11.67.1-Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. Water thinnable cement primer HSR Rate(Rs.) 22.00 Through Rate

8201.74

180438

22

... More
HSR Item 11.98.1-Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 1. New work (Two or more coats applied @ 1.43 litre/ 10 sqm Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm HSR Rate(Rs.) 86.00 Through Rate

5698.76

490093

86

... More
HSR Item 7.97-30 mm red sand stone sun-shade (chisel- dressed) supported on red sand stone brackets, fixed in walls with cement mortar 1:4 (1 cement : 4 coarse sand), including finishing complete. HSR Rate(Rs.) 510.00 Through Rate

204.1

104088

510

... More
HSR Item 6.65-Extra for laying concrete in or under foul positions. HSR Rate(Rs.) 157.00 Through Rate

23.75

3728

157

... More
HSR Item 6.66-Extra for laying reinforced cement concrete in or under water and/ or liquid mud, including cost of pumping or bailing out water and removing slush etc., complete. HSR Rate(Rs.) 360.00 Material Rate

231.06

83182

360

... More
HSR Item 6.27-Extra for R.C.C./ B.M.C/ R.M.C. work above floor IV level for each three floors or part thereof. HSR Rate(Rs.) 244.00 Through Rate

694.76

169522

244

... More
NS Item -PROTECTION DRAIN BOARD : Providing and fixing Drain board of branded organization as protection board for waterproofing which is high strength one side dimpled structure, light in weight 400 ( plus /- 20) gm/sqm yet flexible strong and resilient. Product should be High Density Polyethylene (HDPE) draining system with 8 mm dimples, which helps in fast and efficient drainage of surp us water and controls soil erosion,protects construction, allows water to drain while reducing water table pressure. It is mainly used for,vertical/ horizontal drainage, soil erosion control,and prctects the main waterproofing layer complete as per direction of engineer incharge.

20.86

7049

338

... More
NS Item -Boring with hydraulic pilling rigs with power units/DMC, Providing and Installing cast in Situ single under reemed piles of 500 mm dia and Length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solutions and the length of pile to be embedded in pile cap and including preparation of pile head by dismantling extra loose concrete etc. all complete.. Note:- 1. Length of Pile for payment shall be measured upto the bottom of pile cap 2. No Extra Payment will be made on account of liquid Mud/Daldal removal occured during boring/piling 3. Design mix for Pile shall be prepared from authorized laboratory by the agency. No any payment will be made on account of Extra cement.

1542.24

2956474

1917

... More
Sub-Component Total Amount

-

-

-

... More
Sub-Component :- Type-III 24 Nos (Public Health)

-

-

-

... More
HSR Item 22.85.3-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes HSR Rate(Rs.) 233.00 Through Rate

1799.84

419362

233

... More
HSR Item 22.222.2.3-Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete HSR Rate(Rs.) 273.00 Through Rate

524

143052

273

... More
HSR Item 9.60-Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. HSR Rate(Rs.) 35.00 Through Rate

18

630

35

... More
HSR Item 22.85.2-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR Rate(Rs.) 181.00 Through Rate

60

10860

181

... More
HSR Item 22.98.1-Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore HSR Rate(Rs.) 414.00 Through Rate

48

19872

414

... More
HSR Item 22.98.2-Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore HSR Rate(Rs.) 384.00 Through Rate

50

19200

384

... More
HSR Item 22.101.1.1-Providing and fixing Unplasticised PVC connection pipe with brass unions : 1.1. 30 cm length 15 mm nominal bore HSR Rate(Rs.) 44.00 Through Rate

168

7392

44

... More
HSR Item 22.102.2-Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 2. 150 mm diameter HSR Rate(Rs.) 151.00 Through Rate

48

7248

151

... More
HSR Item 22.86.1-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes HSR Rate(Rs.) 205.00 Through Rate

240

49200

205

... More
HSR Item 22.166.1.1-Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.1. 100x100 mm size P type With common burnt clay non-modular bricks of class designation 7.5 HSR Rate(Rs.) 1457.00 Through Rate

16

23312

1457

... More
HSR Item 22.105.1-Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore HSR Rate(Rs.) 512.00 Through Rate

216

110592

512

... More
HSR Item 22.107.1-Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore HSR Rate(Rs.) 508.00 Through Rate

336

170688

508

... More
HSR Item 20.56.2-Providing and screwing in brass/Gun Metal ferrules drilling and tapping Cast Iron /D.I. /G.I. pipe lines of all diameters and connections including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in- Charge. (Excavation will be paid separately). 2. 10mm i/d ferrule HSR Rate(Rs.) 155.00 Through Rate

24

3720

155

... More
HSR Item 22.104.1-Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore HSR Rate(Rs.) 346.00 Through Rate

48

16608

346

... More
HSR Item 21.84.3-Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR Rate(Rs.) 5438.00 Through Rate

12

65256

5438

... More
HSR Item 6.30.1-Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR Rate(Rs.) 156.00 Through Rate

148.5

23166

156

... More
HSR Item 22.8.2-Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). 2. Two way HSR Rate(Rs.) 2475.00 Through Rate

24

59400

2475

... More
HSR Item 22.109-Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. HSR Rate(Rs.) 49.00 Through Rate

600

29400

49

... More
HSR Item 22.222.2.2-Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete HSR Rate(Rs.) 322.00 Through Rate

448.72

144487

322

... More
HSR Item 22.181-Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR Rate(Rs.) 7.00 Through Rate

24000

168000

7

... More
HSR Item 21.85.3-Extra for every 0.30 metre depth of Inspection chamber 3. 600 mm x 900 mm inside HSR Rate(Rs.) 1138.00 Through Rate

12

13656

1138

... More
HSR Item 20.26.2-Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wall HSR Rate(Rs.) 242.00 Through Rate

84

20328

242

... More
HSR Item 6.1.8-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 8. 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) HSR Rate(Rs.) 2165.00 Through Rate

14.85

32150

2165

... More
HSR Item 2.B1323- B1323. CP grating 100mm dia HSR Rate(Rs.) 89.00 Rate

144

12816

89

... More
HSR Item 20.26.1-Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 1. 11.43 cm thick wall HSR Rate(Rs.) 164.00 Through Rate

77

12628

164

... More
HSR Item 4.16.1.2-Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1.2. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia HSR Rate(Rs.) 62.00 Through Rate

165

10230

62

... More
HSR Item 21.39.4-Jointing and fixing salt glazed stoneware pipes and special in trenches using cement sand mortar 1:1 and best white Italian tarred hemp/yarn including finishing and trowel ling of each joint at an angle of 45 degrees with the longitudinal axis of the pipes, watering, keeping the joints covered and wetted till the same are cured, testing the sewer lines for leakages and making all leakages and defect good, complete as laid down in the contract specifications. 4. 200 mm internal diametre of sewer HSR Rate(Rs.) 75.00 Through Rate

210

15750

75

... More
HSR Item 21.38.4-`Lowering salt glazed stoneware pipes and specials into trenches for all depths and laying out the same to correct alignment gradient, level etc in trenches including all dressing and trimming of bed and sides of trenches, if required, trimming and cutting of concrete beds and joint holes, supporting the pipes and specials, in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching hunching and envelopes are completed. The sewer shall rest on the bed at every point throughout its length and to ensure this, it shall be grouted in without extra charge by the contractor with lime surkhi mortar, in the case of lime concrete beds and 1:3 cement sand mortar in the case of cement concrete beds including cartage from Divisional Store or nearest Railway station to site of work. The internal diameter of sewer being :-` 4. 200 mm internal diameter of sewer HSR Rate(Rs.) 493.00 Through Rate

12.5

6162

493

... More
HSR Item 22.1.3-Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 3. White vitreous chinaware Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps HSR Rate(Rs.) 1818.00 Through Rate

48

87264

1818

... More
HSR Item 22.5-Providing and fixing white vitreous chinaware pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. HSR Rate(Rs.) 1104.00 Through Rate

48

52992

1104

... More
HSR Item 22.10.2.2-Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 2.2. Kitchen sink without drain board610x460 mm bowl depth 200 mm HSR Rate(Rs.) 1924.00 Through Rate

24

46176

1924

... More
HSR Item 22.20.2-Providing and fixing in position C.I. plain Nahani Trap conforming to I.S.I. specifications and of self cleaning design with C.P. brass hinged grating with frame complete 2. With 75 mm internal diameter outlet HSR Rate(Rs.) 1170.00 Through Rate

144

168480

1170

... More
HSR Item 22.33-Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. HSR Rate(Rs.) 10809.00 Through Rate

24

259416

10809

... More
HSR Item 22.14.1.1-Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 1.1. Semi rigid pipe 32 mm dia HSR Rate(Rs.) 46.00 Through Rate

72

3312

46

... More
HSR Item 21.93.2-Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening HSR Rate(Rs.) 1058.00 Through Rate

12

12696

1058

... More
HSR Item 28.14-Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). HSR Rate(Rs.) 375.00 Through Rate

269.62

101106

375

... More
HSR Item 22.86.2-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes HSR Rate(Rs.) 264.00 Through Rate

680.88

179752

264

... More
HSR Item 6.1.3-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 3. 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) HSR Rate(Rs.) 3426.00 Through Rate

33.41

114472

3426

... More
HSR Item 22.38-Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. HSR Rate(Rs.) 241.00 Through Rate

24

5784

241

... More
HSR Item 21.38.2-`Lowering salt glazed stoneware pipes and specials into trenches for all depths and laying out the same to correct alignment gradient, level etc in trenches including all dressing and trimming of bed and sides of trenches, if required, trimming and cutting of concrete beds and joint holes, supporting the pipes and specials, in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching hunching and envelopes are completed. The sewer shall rest on the bed at every point throughout its length and to ensure this, it shall be grouted in without extra charge by the contractor with lime surkhi mortar, in the case of lime concrete beds and 1:3 cement sand mortar in the case of cement concrete beds including cartage from Divisional Store or nearest Railway station to site of work. The internal diameter of sewer being :-` 2. 150 mm internal diameter of sewer HSR Rate(Rs.) 380.00 Through Rate

4

1520

380

... More
HSR Item 21.39.2-Jointing and fixing salt glazed stoneware pipes and special in trenches using cement sand mortar 1:1 and best white Italian tarred hemp/yarn including finishing and trowel ling of each joint at an angle of 45 degrees with the longitudinal axis of the pipes, watering, keeping the joints covered and wetted till the same are cured, testing the sewer lines for leakages and making all leakages and defect good, complete as laid down in the contract specifications. 2. 150 mm internal diametre of sewer HSR Rate(Rs.) 57.00 Through Rate

70

3990

57

... More
HSR Item 22.22.1-Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1. White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests HSR Rate(Rs.) 3493.00 Through Rate

24

83832

3493

... More
HSR Item 22.209-Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. HSR Rate(Rs.) 813.00 Through Rate

96

78048

813

... More
NS Item -`SITC of Ball valves with and without strainers alongwith fittings etc of sizes:` 32 mm dia without Strainer Make : RC/Anergy/Advance

48

61008

1271

... More
NS Item -`SITC of Ball valves with and without strainers alongwith fittings etc of sizes:` 25 mm dia without Strainer Make : RC/Anergy/Advance

48

40656

847

... More
NS Item -Providing and fixing CPVC Ball valve of 20 mm dia including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge.

48

6528

136

... More
NS Item -Providing and fixing 20 mm CPVC Union in CPVC pipe including cutting and Jointing the pipe with solution etc. complete

144

16848

117

... More
NS Item -Providing and fixing 25mm CPVC Union in CPVC pipe including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge .

144

30816

214

... More
NS Item -Providing and fixing 32mm dia CPVC Union in CPVC pipe including cutting and Jointing the pipe with solution etc. complete in all respects as per direction of engineer incharge

144

43920

305

... More
NS Item -Providing and fixing Towel Ring round with round flange of Jaquar make (ACN-1121BN) or equivalent approved brand complete in all respects to the satisfection of engineer in charge.

48

45504

948

... More
HSR Item 22.103.3-Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore HSR Rate(Rs.) 292.00 Through Rate

24

7008

292

... More
NS Item -Providing and fixing CPVC tank connector/ tank nipple 32 mm including cutting hole and Jointing the pipe in water tank with solution etc. complete in all respects as per direction of engineer incharge

48

10080

210

... More
NS Item -Providing and fixing CPVC tank connector/ tank nipple 25 mm including cutting hole and Jointing the pipe in water tank with solution etc. complete in all respects as per direction of engineer incharge

48

6864

143

... More
NS Item -Providing and fixing CPVC tank connector/ tank nipple 20 mm dia including cutting hole and Jointing the pipe in water tank with solution etc. complete in all respects as per direction of engineer incharge

48

2400

50

... More
HSR Item 2.B1332- B1332. Soap Dish HSR Rate(Rs.) 445.00 Rate

96

42720

445

... More
HSR Item 2.B1505- B1505. PTMT - Towel Rail (600 mm long) HSR Rate(Rs.) 147.00 Rate

48

7056

147

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 90 mm dia . Coupler

64

5376

84

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia Coupler

64

6592

103

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 90 mm dia . Single Tee with Door

94

17296

184

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia Single Tee with door

80

17360

217

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 90 mm dia . Vent Cowl

56

1960

35

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia Vent Cowl

56

2240

40

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 90 mm dia . Bend 87.5 degree

112

12768

114

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia Bend 87.5 degree

112

16352

146

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia Single Tee

24

4488

187

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia . P-Trap

48

18912

394

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia . Nahani Trap without Jali (110x90) mm

72

13608

189

... More
NS Item -Providing and fixing UPVC SWR fittings/accessories for UPVC SWR pipes including jointing with solvent etc. complete in all respects. For 110 mm dia Nahani Trap without Jali (110x110) mm

120

25920

216

... More
NS Item -Providing and Fixing Powder Coated aluminum I- Hook 150mm Long Included Labour for fixing complete in all respect.

240

7440

31

... More
Sub-Component Total Amount

-

-

-

... More
Sub-Component :- Rain Water Harvesting

-

-

-

... More
HSR Item 33.16.2-Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 2. 150 mm dia HSR Rate(Rs.) 183.00 Through Rate

1

183

183

... More
HSR Item 6.30.3-Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform HSR Rate(Rs.) 208.00 Through Rate

23.18

4821

208

... More
HSR Item 10.100.1-Cement Concrete 1:8:16 Flooring 1. Cement Concrete 1:8:16 with Over burnt (Jhama) Brick Aggregate: 90 mm to 40 mm size in foundation and plinth. HSR Rate(Rs.) 1727.00 Through Rate

3.78

6534

1727

... More
HSR Item 33.7.1.1-Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre and up to 150 metre depth below ground level. 1.1. All types of soil 300 mm dia HSR Rate(Rs.) 596.00 Through Rate

110

65560

596

... More
HSR Item 33.9.2-Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in- charge. 2. 150 mm nominal size dia HSR Rate(Rs.) 642.00 Through Rate

60

38520

642

... More
HSR Item 33.12-Supplying, filling, spreading and levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. HSR Rate(Rs.) 1039.00 Through Rate

6.47

6722

1039

... More
HSR Item 33.13-Supplying, filling, spreading and levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineer-in- charge. HSR Rate(Rs.) 1039.00 Through Rate

5.09

5284

1039

... More
HSR Item 33.8.2-Supplying, assembling, lowering and fixing in vertical position in bore well, Unplasticised PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 2. 150 mm nominal size dia HSR Rate(Rs.) 594.00 Through Rate

50

29700

594

... More
HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 84.00 Through Rate

72.68

6104

84

... More
HSR Item 33.14-Supplying, filling, spreading and levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer -in-charge. HSR Rate(Rs.) 1039.00 Through Rate

2.54

2642

1039

... More
HSR Item 6.1.1-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) HSR Rate(Rs.) 3975.00 Through Rate

1.26

5016

3975

... More
HSR Item 7.21.1-Brick work with common burnt clay non- modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR Rate(Rs.) 3693.00 Through Rate

17.72

65428

3693

... More
HSR Item 6.43-Providing, hoisting and fixing above plinth level up to floor four level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone- III) : 3 graded stone aggregate 20 mm nominal size). HSR Rate(Rs.) 4174.00 Through Rate

0.06

250

4174

... More
HSR Item 6.33.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR Rate(Rs.) 61.00 Through Rate

600

36600

61

... More
HSR Item 4.12.1-Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer- in-charge. 1. All kinds of soil HSR Rate(Rs.) 78.00 Through Rate

174.43

13605

78

... More
HSR Item 9.57.3-Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter HSR Rate(Rs.) 269.00 Through Rate

452.44

121706

269

... More
HSR Item 9.58.5.3-Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5° 150 mm bend HSR Rate(Rs.) 129.00 Through Rate

4

516

129

... More
HSR Item 4.31.1-Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 1. All kinds of soil HSR Rate(Rs.) 51.00 Through Rate

171.41

8741

51

... More
HSR Item 33.17.2-Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 2. 150 mm clamp HSR Rate(Rs.) 1191.00 Through Rate

1

1191

1191

... More
HSR Item 33.18.2-Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 2. 150 mm dia HSR Rate(Rs.) 236.00 Through Rate

1

236

236

... More
HSR Item 22.198.1-Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 1. With 20x20 mm square bar HSR Rate(Rs.) 243.00 Through Rate

2

486

243

... More
HSR Item 22.200.2-Supplying and fixing C.I. cover without frame for manholes : 2. 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg HSR Rate(Rs.) 2702.00 Through Rate

2

5404

2702

... More
HSR Item 4.32-Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR Rate(Rs.) 46.00 Through Rate

108.39

4985

46

... More
HSR Item 21.93.1-Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 1. Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening HSR Rate(Rs.) 1155.00 Through Rate

2

2310

1155

... More
HSR Item 6.16-Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). HSR Rate(Rs.) 6113.00 Through Rate

1.28

7824

6113

... More
HSR Item 11.6.1-15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 102.00 Through Rate

72.68

7413

102

... More
HSR Item 6.1.6-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR Rate(Rs.) 2442.00 Through Rate

0.73

1775

2442

... More
HSR Item 33.15-Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineer-in- charge. HSR Rate(Rs.) 1166.00 Through Rate

5.83

6797

1166

... More
HSR Item 13.29.2-Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR Rate(Rs.) 83.00 Through Rate

800

66400

83

... More
Sub-Component Total Amount

-

-

-

... More
Sub-Component :- Boundary wall and Road

-

-

-

... More
HSR Item 6.16-Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). HSR Rate(Rs.) 6113.00 Through Rate

21.72

132743

6113

... More
HSR Item 7.21.1-Brick work with common burnt clay non- modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR Rate(Rs.) 3693.00 Through Rate

39.94

147502

3693

... More
HSR Item 11.60-Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR Rate(Rs.) 59.00 Through Rate

1413

83367

59

... More
HSR Item 6.30.6-Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts HSR Rate(Rs.) 262.00 Through Rate

306.18

80219

262

... More
HSR Item 11.98.1-Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 1. New work (Two or more coats applied @ 1.43 litre/ 10 sqm Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm HSR Rate(Rs.) 86.00 Through Rate

1413

121518

86

... More
HSR Item 6.30.1-Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete HSR Rate(Rs.) 156.00 Through Rate

321.55

50161

156

... More
HSR Item 6.30.5-Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers HSR Rate(Rs.) 296.00 Through Rate

188.82

55890

296

... More
HSR Item 10.78-Providing and laying 100mm thick factory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design and shape, laid in required colour and pattern over (BIS 15658:2006) and including 60mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. HSR Rate(Rs.) 664.00 Through Rate

3546.49

2354866

664

... More
HSR Item 17.14.2-Granular Sub-Base with Close Graded Material - (Table:- 400-1) Plant mix method Construction of granular sub-base by providing Material as per Grading III (Table 400-I of MORTandH 5th revision) mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORTandH specifications 2. Grading II material HSR Rate(Rs.) 1187.00 Through Rate

702.73

834139

1187

... More
HSR Item 17.73-Construction of unreinforced plain cement concrete pavement in M-25 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORTH specifications HSR Rate(Rs.) 4873.00 Through Rate

655.5

3194241

4873

... More
HSR Item 10.4-Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. HSR Rate(Rs.) 88.00 Through Rate

1217.6

107148

88

... More
HSR Item 21.87.1.1-Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item No.10.6) in foundations 1st class brick work laid in cement sand mortar 1:5, 40 mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12mm in thickness of 1:2 cement sand plaster and finished with floating coat of neat cement 1 mm thick left absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar (as Specified in item No. Item 21.48) complete to the requirement of the Engineer in-charge 1.1. Single road gully chamber - Size: 610mm x 457mm x 800mm HSR Rate(Rs.) 3237.00 Through Rate

46

148902

3237

... More
HSR Item 6.1.6-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) HSR Rate(Rs.) 2442.00 Through Rate

736.14

1797663

2442

... More
HSR Item 4.14.1-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. HSR Rate(Rs.) 83.00 Through Rate

229.84

19076

83

... More
HSR Item 6.14.1-Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone- III): 3 graded stone aggregate 20 mm nominal size) HSR Rate(Rs.) 4374.00 Through Rate

46.93

205267

4374

... More
HSR Item 7.22.1-Brick work with common burnt clay non- modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) HSR Rate(Rs.) 3877.00 Through Rate

121.16

469717

3877

... More
HSR Item 11.5.3-12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 84.00 Through Rate

742.69

62386

84

... More
HSR Item 11.6.1-15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand) HSR Rate(Rs.) 102.00 Through Rate

670.31

68371

102

... More
HSR Item 17.5.3-Compacting Original Ground 3. Compaction of Earthwork Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications HSR Rate(Rs.) 7.00 Through Rate

5867.07

41069

7

... More
HSR Item 22.170.1-Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 1. 450 mm dia RCC pipes. HSR Rate(Rs.) 2145.00 Through Rate

20

42900

2145

... More
HSR Item 6.15.1-Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone- III) : 3 graded stone aggregate 20 mm nominal size) HSR Rate(Rs.) 5969.00 Through Rate

27.68

165192

5969

... More
HSR Item 6.33.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR Rate(Rs.) 61.00 Through Rate

13804

842044

61

... More
HSR Item 6.34.6-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR Rate(Rs.) 61.00 Through Rate

4091

249551

61

... More
NS Item -Supply and Filling of good quality local earth brought from the outside of the building of any irrespective lead and lift including transporation i.e carriage loading and unloading and leveliing and compaction as per MORT and H specification in 15cm layer under the floor of building and pavment/road and other places of site complete in all respect as per entire satisfaction of Engineer- In-Charge. Note- All necessary approval, permissions and royalty if required will be borne by the agency/Contractor

7192.69

2035530

283

... More
HSR Item 4.16.1.1-Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1.1. All kinds of soil Pipes, cables etc, not exceeding 80 mm dia. HSR Rate(Rs.) 55.00 Through Rate

710

39050

55

... More
HSR Item 6.1.7-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) HSR Rate(Rs.) 2192.00 Through Rate

63.9

140068

2192

... More
HSR Item 6.1.2-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) HSR Rate(Rs.) 3476.00 Through Rate

63.9

222116

3476

... More
HSR Item 21.95.1-Providing lowering cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot and socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.44, item 21.45, and item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being: 1. 350 mm HSR Rate(Rs.) 991.00 Through Rate

710

703610

991

... More
HSR Item 21.84.3-Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR Rate(Rs.) 5438.00 Through Rate

25

135950

5438

... More
HSR Item 21.85.3-Extra for every 0.30 metre depth of Inspection chamber 3. 600 mm x 900 mm inside HSR Rate(Rs.) 1138.00 Through Rate

25

28450

1138

... More
HSR Item 21.93.2-Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening HSR Rate(Rs.) 1058.00 Through Rate

25

26450

1058

... More
NS Item -Cutting groove in cement concrete work in road/ taxi track of size 50mm deep.

2157.37

60406

28

... More
Sub-Component Total Amount

-

-

-

... More
Sub-Component :- Fire Fighting

-

-

-

... More
HSR Item 22.83-Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. HSR Rate(Rs.) 138.00 Through Rate

8

1104

138

... More
HSR Item 25.3.6-Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 6. 100mm dia. HSR Rate(Rs.) 2664.00 Through Rate

16

42624

2664

... More
HSR Item 22.98.1-Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore HSR Rate(Rs.) 414.00 Through Rate

32

13248

414

... More
HSR Item 22.181-Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR Rate(Rs.) 7.00 Through Rate

20000

140000

7

... More
NS Item -Fire Exit Singages Single Side Size 16` x 6` Including Labour and Fixing

28

17304

618

... More
NS Item - 19 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 19.1 2 way-100 mm dia M.S. Pipe (NS Based on DSR)

4

23024

5756

... More
NS Item -20 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. (NS Based on DSR)

4

62928

15732

... More
NS Item -7 Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required (NS Based on DSR)

40

16440

411

... More
NS Item -16 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 16.2 Stainless Steel (Grade 304) NS Based on DSR

56

216944

3874

... More
NS Item -17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. (a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 (b) 20 mm nominal internal dia gun metal globe valve and nozzle. (c) Drum and brackets for fixing the equipmets on wall. (d) Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket. 17.1 30 m (NS Based on DSR)

28

205772

7349

... More
NS Item -22 Providing and fixing of pressure switch in M.S. pipe line including connection etc. as required. (NS based on DSR)

4

5268

1317

... More
NS Item -23 Providing and fixing flow switch in following sizes M.S. pipe including connection etc as required. 23.1 100mm dia (NS Based on DSR)

4

25724

6431

... More
NS Item -Supply and Installation of Water CO2 9LTR Fire Extinguisher Complete in all respect.( Make MEC,Lifeline)

28

92932

3319

... More
NS Item -Providing and Fixing in position the industrial type pressure gauge with gunmetal complete in all respect.WITHOUT GST

4

5328

1332

... More
NS Item -Providing and Fixing of Double door MS Sheet Hose Box with (30`x24`x10`) sizes front glass and lockable facility to accommodate hose pipe and branch pipe. without GST

32

246240

7695

... More
NS Item -4 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical confirming to IS :1520 (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-`F` insulation, conforming to IS- 325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 4.2 (450 LPM at 25m Head) NS Based on DSR. WITHOUT GST

4

292632

73158

... More
NS Item -Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 14.5- 100mm dia (NS Based on HSR 2021)

8

74352

9294

... More
NS Item -Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. (NS Based on DSR)

28

30996

1107

... More
NS Item -Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 9.1 Single headed gunmetal (NS Based on DSR)

28

179984

6428

... More
NS Item -11. Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 11.5 100 MM dia (NS Based on DSR)

20

110720

5536

... More
NS Item -ABC Fire Extinguisher 4 KG included Labour and Fixing (MEC, Lifeline. WITHOUT GST

28

40320

1440

... More
NS Item -7 Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 7.2 (32mm Dia (NS Based on DSR) WITHOUT GST

40

18080

452

... More
NS Item -7 Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 7.7 (100mm dia) (NS Based on DSR). without GST..

400

514240

1285.6

... More
NS Item -Supply and Installation of CO2 4.5 Kg Fire Extinguisher Complete in all respect. (Make MEC, Lifeline)

28

190876

6817

... More
Sub-Component Total Amount

-

-

-

... More
Sub-Component :- Dismantling and Recovery Part

-

-

-

... More
HSR Item 2.B0154- B0154. Common burnt clay F.P.S. (non modular) bricks class designation 7.5 HSR Rate(Rs.) 4108.00 Rate

53.99

-221807

4108

... More
HSR Item 2.B0146- B0146. Brick bats HSR Rate(Rs.) 357.00 Rate

74.99

-26770

357

... More
HSR Item 5.7.4-Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar HSR Rate(Rs.) 585.00 Through Rate

187.48

109675

585

... More
Sub-Component Total Amount

-

-

-

... More
E.I. (HSR) PART

-

-

-

... More
HSR Item 23.8.10.1-FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data HSR Rate(Rs.) 93.00 Through Rate

384

35712

93

... More
HSR Item 23.8.10.2-FITTING AND ACCESSORIES 10.2. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 Modules HSR Rate(Rs.) 127.00 Through Rate

384

48768

127

... More
HSR Item 23.8.10.6-FITTING AND ACCESSORIES 10.6. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 12 Modules HSR Rate(Rs.) 282.00 Through Rate

672

189504

282

... More
HSR Item 23.8.11.4-FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket HSR Rate(Rs.) 82.00 Through Rate

1920

157440

82

... More
HSR Item 23.4.2.1-COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 2.1. Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A HSR Rate(Rs.) 804.00 Through Rate

288

231552

804

... More
HSR Item 23.8.11.1-FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch HSR Rate(Rs.) 41.00 Through Rate

1920

78720

41

... More
HSR Item 23.8.11.9-FITTING AND ACCESSORIES 11.9. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. T.V. Socket outlet modular type HSR Rate(Rs.) 75.00 Through Rate

288

21600

75

... More
HSR Item 23.8.11.10-FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate HSR Rate(Rs.) 18.00 Through Rate

2400

43200

18

... More
HSR Item 23.8.11.7-FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt HSR Rate(Rs.) 257.00 Through Rate

288

74016

257

... More
HSR Item 23.22.4.3-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.3. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 12 way ( 2 incoming and 10 outgoing) HSR Rate(Rs.) 1706.00 Through Rate

96

163776

1706

... More
HSR Item 23.22.5.1-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole HSR Rate(Rs.) 145.00 Through Rate

960

139200

145

... More
HSR Item 23.22.5.4-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole HSR Rate(Rs.) 677.00 Through Rate

96

64992

677

... More
HSR Item 9.59.3-Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 3. 150 mm HSR Rate(Rs.) 154.00 Through Rate

320

49280

154

... More
HSR Item 20.71.1-Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48" (1200mm) HSR Rate(Rs.) 2054.00 Through Rate

288

591552

2054

... More
HSR Item 20.72-Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. HSR Rate(Rs.) 1339.00 Through Rate

288

385632

1339

... More
HSR Item 23.4.4.1-COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.1. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A HSR Rate(Rs.) 725.00 Through Rate

960

696000

725

... More
HSR Item 23.7.6.2-PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. HSR Rate(Rs.) 32.00 Through Rate

1920

61440

32

... More
HSR Item 23.4.5.1-COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.1. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A HSR Rate(Rs.) 999.00 Through Rate

576

575424

999

... More
HSR Item 23.7.6.3-PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia. HSR Rate(Rs.) 45.00 Through Rate

2880

129600

45

... More
HSR Item 23.8.4-FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. HSR Rate(Rs.) 95.00 Through Rate

288

27360

95

... More
HSR Item 24.1.2-EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. HSR Rate(Rs.) 652.00 Through Rate

40

26080

652

... More
HSR Item 24.1.11-EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. HSR Rate(Rs.) 189.00 Through Rate

400

75600

189

... More
HSR Item 24.1.13-EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. HSR Rate(Rs.) 21.00 Through Rate

800

16800

21

... More
HSR Item 24.5.2.5-MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia HSR Rate(Rs.) 241.00 Through Rate

320

77120

241

... More
HSR Item 23.3.6.1-COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) HSR Rate(Rs.) 88.00 Through Rate

14400

1267200

88

... More
HSR Item 24.1.1-EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. HSR Rate(Rs.) 2721.00 Through Rate

40

108840

2721

... More
NS Item -Supply and erection of 4 Sqmm ISI marked, FRLS PVC insulated, single core copper conductor cable Make- Grandlay or as approved in HPHC brand List

19200

633600

33

... More
HSR Item 23.8.5-FITTING AND ACCESSORIES 5. Supply and erection 5-30 A single phase A.C. energy metre , LCD display and optical port , with rag bolts on wall/existing pedestal including the cost of rag bolts required to complete the job in all respect with necessary connections and bonding to earth. HSR Rate(Rs.) 1715.00 Through Rate

96

164640

1715

... More
HSR Item 23.4.1.1-COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A HSR Rate(Rs.) 520.00 Through Rate

3516

1828320

520

... More
HSR Item 23.20-Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required HSR Rate(Rs.) 67.00 Through Rate

636

42612

67

... More
NS Item -Supply of PVC/ XLPE insulated (Heavy Duty ) Electrical cables for working voltage upto 1100 volt to IS: 1554 (PART-1) with Aluminium Conductor- ISI Marked Power Cable- Aluminium Conductor (16 sqmm 2 core armoured/ unarmoured as per requirment/ enegineer in charge). Make - Grandlay ( price list w.e.f from 24.01.2022) as per HPHC Brand List WITHOUT GST

9600

1286400

134

... More
NS Item -SITC of Solar Operated fully Stainless Steel Body Water Cooler (Make- climatrol / usha or as per HPHC approved Brand List ) of 40 litre cooling capacity and 80 litre storage capacity with inbuilt RO ( Make - Kent) of 50 LPH RO/ UV/UF capacity - 1 no Solar off grid plant 1 Kwp ( 3 Panel, 1 inverter, 2 Battery ) Complete the all necessary connection in all respect. AS Per HPHC Brand List

1

214513

214513

... More
NS Item -SITC of fully stainless steel body 150 ltr cooling and 150 ltr storage capacity water cooler with 2 no taps,locking arrangemeny with 5 KVA 170/270 v rating copper wound stablizer ( stablizer Make:- V-Guard ,microtek,luminious,voltas) complete in all respect. Make - as per HPHC approved brand list

1

52030

52030

... More
NS Item -SITC of Commercial RO / Water purifier Capacity 50 LPH Complete with making necessary connection in all respect. Make - as per HPHC brand list

1

41219

41219

... More
NS Item -Supply and erection of 1.5 sq. mm ISi marked, FRLS PVC insulated, single core copper conductor cable .Make:- as per HPHC approved Brand List without gst

48000

696000

14.5

... More
NS Item -Supply and erection of 10 sq. mm ISi marked, FRLS PVC insulated, single core copper conductor cable .Make:- as per HPHC approved Brand List WITHOUT GST

4800

441600

92

... More
NS Item -Supply and erection of 6 sq. mm ISi marked, FRLS PVC insulated, single core copper conductor cable .Make:- as per HPHC approved Brand List WITHOUT GST

9600

384000

40

... More
NS Item -Supply of 18/20 watt rating 4 feet long LED Tube light Batten suitable for operation on 230 volt, 50 Hz supply. Make:- Havells or as per HPHC approved brand list

636

133560

210

... More
NS Item -Supply and installation of fire existingusher ABC type 4 kg capacity duly erected / hangs on the wall with hooks i.c the cost of hook ,screw etc with all material required to complete the job in all respact. WITHOUT GST

28

81536

2912

... More
NS Item -S/E of L.T. energy meters Panel made out of 16 guage CRCA sheet with double shutter and locking arrangment consisting of legs of M.S angle iron of size 50 mmx50 mmx 6mm, 0.90mtr hight embeded in C.C. Block 1:2:4 projected 100 mm all around the panel 600 mm depth, 1 no 4 pole MCCB of 400 amp, 25 KA breaking capacity, 4Nos. Aluminium busbar of size 50mm x12mm, internal copper wiring 10 sqmm size, hollock wooden board 20mm thick for fixing of energy meters and 24 nos 63 A SPN MCB, complete in all respect with all labour, petty material, painting and making necessary connections etc. (Design as approved by DHBVN/UHBVN). i) For 24 No`s energy metre (Apporx. panel size 86` x 72` x 16`) (Apporx. space for each energy meter 425mm x300mm x16mm, apporx. space for Bus- bar 450mm x1800mm x 16mm) without gst

4

540000

135000

... More
NS Item -`ESE-TYPE LIGHTNING ARRESTER ESE lightning air terminal with the below technical parameters,- stainless steel material (304-L)- Suitable for corrisive environment - temparture 60 micro seconds. METU lab tested as per NF C-17-102(2011) standard- CPRI tested for 70 KA (8/20 micro sec) = 1 no. Lightning current= 100KA (10/350micro sec) tested 20 years warranty. Protection radius=107 mtrs.( Level IV/very high) Model: SIRIUS Make TOPBAS ( Turkey, Europe), /safesheild / KALRE). Lightning Counter = 1 no. Supply 17.2mm dia copper bonded-soild electrode with 50kg chemical (25kgx2BAG) with tir-port and Pit cover. = 3 nos. 70 Sqmm single core pure copper cable with thimble ( make PoLYCAB, havells, grandlay, finolex or HPHC approved brand list. Aviation Lamp light with wiring = 1 no complete the work including installation charges OBO,JVL`

2

309926

154963

... More
Electrical ( A Part )

-

-

-

... More
Estate Electrical Work ( B Part)

-

-

-

... More
HSR Item 24.3.2.1-HT CABLE 2.1. Laying and erection of XLPE II or 33 kv HT aluminium conductor armoured cable ISI mark laid on surface/pipe/cable tray with all labour and material as required up to 120 sqmm 3 core XLPE Cable HSR Rate(Rs.) 78.00 Through Rate

500

39000

78

... More
NS Item -Supply and erection of R.D. fuses fixed on 2 Nos. channels of (set of 6 Nos) insulators pactel make size 75 mmx40 mmx6mm 2.25 mt. long with the help of suitable sizes of MS clamps, nuts and bolts i/c painting necessary connectiona and labour on existing pole complete in all respect

1

5336

5336

... More
HSR Item 24.1.3-EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. HSR Rate(Rs.) 3368.00 Through Rate

12

40416

3368

... More
NS Item -Supply of PVC/ XLPE insulated (Heavy Duty ) Electrical cables for working voltage upto 1100 volt to IS: 1554 (PART-1) with Aluminium Conductor- ISI Marked Power Cable- Aluminium Conductor (300 sqmm 3.5 core armoured/ unarmoured as per requirment/ enegineer in charge). Make - Grandlay or as per approved HPHC Brand list (Price list w.e.f. dated 24.01.2022)

400

714400

1786

... More
HSR Item 24.3.4.1-HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm HSR Rate(Rs.) 11516.00 Through Rate

22

253352

11516

... More
HSR Item 24.1.5-EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. HSR Rate(Rs.) 801.00 Through Rate

10

8010

801

... More
HSR Item 24.1.7-EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. HSR Rate(Rs.) 360.00 Through Rate

100

36000

360

... More
HSR Item 24.1.8-EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. HSR Rate(Rs.) 96.00 Through Rate

150

14400

96

... More
NS Item - SITC of cubical type dust and vermine proof H.T Metering panel free for standing floor mounting suitable for 11 kv 3 phase supply made out of 14 gauge MS sheet with channal from base frame painted with stoving synethic light gray enameled paint suitable for operation on 11az kv 3 phase 50 cycle system effective erthed system1.) Cubical boxes approved by UHBVN/DHBVN of 14 SWG MILD STEEL sheet with double door space and double meter arrangement 11 Kv epoxy testing of burden 10 VAA Class 0.52.) 3 nos C.T of required capacity of stova burden class 0.5 of approved make by as per aggrement list ofOne no PT11/kv/110 volts 3 phase oil cooled 10 va class 0.5 of make as approved make by UHBVN3.) 2 Noside cable end boxes for incoming and outgoing 11 Kv cable with suitable copper bus bars. 4.) Electronic Trivactor meter 11 KV HT of required capacity class A as per requirement of 11 KV /110 volts approved make of UHBVN/DHBVN ISImarked the panel will be complete with all internal wiring inter connection VT and HT compound filling of cable and boxes, HT cable connection etc. complete in all respect as approved by UHBVN/DHBVN authorities including the cost of CT/PT ,electronics meter,Test fees of euipments tested by UHBVN/DHBVN authorities upto the entire satisfaction of Engineer in Charges of the work.As per approved list of HVPN/DHBVN/UHBVN. 5.) Testing fees for CT and PT as approved by HVPN/DHBVN/UHBVN

1

102266

102266

... More
NS Item -S/E of PVC/ XLPE insulated (Heavy Duty ) 50 sqmm 3 core HT Electrical cables for working voltage upto 11000 volt with Aluminium Conductor- ISI Marked Power Cable- Aluminium Conductor (50 sqmm 3 core HT Cable armoured). Make - Polycab w.e.f. Dtd : 5th July 2022

500

467000

934

... More
HSR Item 23.26.1-SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. HSR Rate(Rs.) 76.00 Through Rate

6

456

76

... More
HSR Item 23.26.2-SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. HSR Rate(Rs.) 93.00 Through Rate

3

279

93

... More
HSR Item 23.26.3-SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame. HSR Rate(Rs.) 262.00 Through Rate

2

524

262

... More
HSR Item 24.1.4-EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. HSR Rate(Rs.) 8275.00 Through Rate

4

33100

8275

... More
NS Item -Supply and erection of stay set suitable for 9 /11 Mts. Long PCC Pole made out of 7/8 SWG, GI Wire with U type M S. rod 5/8` dia duly threaded by means of angle iron of size 50 mm x 6mmx30 cm and 6 ft. long M.S. rod 5/8 dia 5` buried in the ground after fixing with cross channel of size 75mmx40mmx60cm.complete in all respect.

3

10113

3371

... More
NS Item -Supply and erection of H-Pole structure made out of 2 Nos. channel of size 100 mm x50mm x6mm 2.25 long, 6 Nos. M.S Channel of size 75 mmx40mmx6mm,0.75m long and 3Nos. M.S. angle iron 50 mm x50mmx6mm , 2.25 Mtr. For laying earth wire on existing PCC Poles i/c necessary M.S. Flat 50mmx6mm size clamps, nuts andbolts i/c painting complete in all respect with all labour and material required to complete the job upto entire satisfaction of E.I.C of the work. (Over all wt. of M.S. parts should not less than 193.5 kg.

1

18418

18418

... More
HSR Item 24.3.3.1-HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm HSR Rate(Rs.) 7149.00 Through Rate

6

42894

7149

... More
NS Item - Supply and erection of lightening arrestor model SDU suitable for 11 KV. 3 phase, 50 cycle, per second grounded neutal system comprising of spark gap type quench gap in service with no linear resistor element housed in along with mountering clamps and confirming to ISS -3070(Part-1) of 1988 with latest amendment on existing channels with labour and material required to complete the job in all respect upto entire satisfaction of Engineer-incharge of the work.

1

3202

3202

... More
NS Item -Sitc of fire existingusher ABC type 4 kg capacity duly erected / hangs on the wall with hooks i.c the cost of hook ,screw etc with all material required to complete the job in all respact

4

12216

3054

... More
NS Item -Supply and erection of 11 KV G.O.D.O. Panel with 25x5 mm size copper bus- bar contacts including suitable M.S. Stand Complete the all necessary connection in all respect.

1

43569

43569

... More
HSR Item 20.86-Supply, erection, testing and commissioning of G.O. Switch two poles, with blade, pin 6 insulators operating handle with GI pipe 25 mm class B complete in all respects. HSR Rate(Rs.) 36814.00 Through Rate

1

36814

36814

... More
HSR Item 24.2.4.5-LT CABLE 4.5. Laying of underground cable in pipe /existing open/closed trench etc as required:- 300 sqmm to 400 sqmm 3 to 3½ Core HSR Rate(Rs.) 29.00 Through Rate

400

11600

29

... More
HSR Item 24.4.10.3-STREET LIGHT 10.3. Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required. Above 6 metre and up to 8.0 metre HSR Rate(Rs.) 2099.00 Through Rate

2

4198

2099

... More
HSR Item 24.4.10.4-STREET LIGHT 10.4. Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required. Above 8.0 metre and up to 11.0 metre HSR Rate(Rs.) 2157.00 Through Rate

4

8628

2157

... More
NS Item -Supply and erection of lightening arrestor model SDU suitable for 11 KV. 3 phase, 50 cycle, per second grounded neutal system comprising of spark gap type quench gap in service with no linear resistor element housed in along with mountering clamps and confirming to ISS -3070(Part-1) of 1988 with latest amendment on existing channels with labour and material required to complete the job in all respect upto entire satisfaction of Engineer-incharge of the work. WITHOUT GST

1

3154

3154

... More
NS Item -Supply and erection of R.D. fuses fixed on 2 Nos. channels of (set of 6 Nos) insulators pactel make size 75 mmx40 mmx6mm 2.25 mt. long with the help of suitable sizes of MS clamps, nuts and bolts i/c painting necessary connectiona and labour on existing pole complete in all respect. without GST

1

5219

5219

... More
NS Item -Supply and erection of H-Pole structure made out of 2 Nos. channel of size 100 mm x50mm x6mm 2.25 long, 6 Nos. M.S Channel of size 75 mmx40mmx6mm,0.75m long and 3Nos. M.S. angle iron 50 mm x50mmx6mm , 2.25 Mtr. For laying earth wire on existing PCC Poles i/c necessary M.S. Flat 50mmx6mm size clamps, nuts andbolts i/c painting complete in all respect with all labour and material required to complete the job upto entire satisfaction of E.I.C of the work. (Over all wt. of M.S. parts should not less than 193.5 kg WITHOUT GST

1

20625

20625

... More
NS Item -Supply and erection of stay set suitable for 9 /11 Mts. Long PCC Pole made out of 7/8 SWG, GI Wire with U type M S. rod 5/8` dia duly threaded by means of angle iron of size 50 mm x 6mmx30 cm and 6 ft. long M.S. rod 5/8 dia 5` buried in the ground after fixing with cross channel of size 75mmx40mmx60cm.complete in all respect. WITHOUT GST

3

11325

3775

... More
NS Item -Supply of PVC/ XLPE insulated (Heavy Duty ) Electrical cables for working voltage upto 1100 volt to IS: 1554 (PART-1) with Aluminium Conductor- ISI Marked Power Cable- Aluminium Conductor (50 sqmm 3.5/ 4 core armoured/ unarmoured as per requirment/ enegineer in charge). Make - Grandlay ( price list w.e.f from 24.01.2022) as per HPHC Brand List

500

179000

358

... More
NS Item -Supply of PVC/ XLPE insulated (Heavy Duty ) Electrical cables for working voltage upto 1100 volt to IS: 1554 (PART-1) with Aluminium Conductor- ISI Marked Power Cable- Aluminium Conductor (300 sqmm 3.5/4 core armoured/ unarmoured as per requirment/ enegineer in charge). Make - Grandlay or as per approved HPHC Brand list. without gst

400

680000

1700

... More
NS Item -COMPACT SUB STATION-250 KVA CSS-250 KVA - Supply, installation, testing and commissioning of distribution 11/0.433 kv Outdoor, 250 KVA, Compact Sub Station as per below specifications (Make : SIEMENS/SCHNEIDER /ABB) HT SWITCHGEAR 11kV 630Amps 21KA/3 sec. Non- Extensible Ring Main Unit Compact switchgear consisting of (CCV) Two Number Fixed Manual Load break switches and One Number Fixed Manual Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure (2.5 mm thick) with series trip, self powered microprocessor based numerical over current and earth fault relay protection . Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium Unarmoured XLPE cable (Make: SIEMENS /Schneider/ ABB) -_ 1 No. in each Incoming and Outgoing Load break switches shall be suitable for cable termination of 3C x 300 sq.mm Cable.

2

4771900

2385950

... More
Incoming Cable termination kits shall be in purchaser scope of supply only Relay shall be of Ashida make of Model No: ADR241S (50,50N,51,51N) with communication port -_ 1 No. in each Protection CT shall be /1A 2.5VA 10P10. (Make: Ericon/Bharti Electricals/ECS/Equiv) -_ 1 Set in each Voltage Presence Indicator -_ 1 Set in each Fault Passage Indicator for Incoming C module Only -_ 1 No. in each Shunt trip coil rating- 230V AC. -_ 1 Set in each Padlocking facility -_ 1 No. in each Manometer -_ 1 No. in each All modules of the RMU shall be capable for cable termination of 3C x 300 sq.mm unarmoured Al XLPE Cable, incoming cable termination kits shall be in the scope of purchaser only. TRANSFORMER 11/0.433KV, 250KVA Copper Wound, Oil cooled transformer as per IS-1180-L2 with copper winding plus 5 to -5 and voltage variation in steps of 2.5% Off load tap changer -_ 1 No. in each LVS PANEL 400 AMPS ALUMINIUM BUSBAR (100% FOR PHASES AND 50% FOR NEUTRAL) - CURRENT DENSITY OF ALUMINIUM 1 A/sq.mm, LT panel made up of 1.5/2mm CRCA sheet with IP4X degree of ingress protection INCOMER FROM TRANSFORMER 400 Amps 433V 4 P 50Hz 50KA MCCB with Microprosser based release for Overload , Shortcircuit and Earth Fault protection (Make : SIEMENS) -_ 1 No. in each RYB, ON/OFF Trip Indication with MCB protection -_ 1 Set in each Control MCB -_ 1 Set in each OUTDOOR ENCLOSURE Outdoor type enclosure having construction of Galvanised Sheet Steel having 2mm thickness for Load bearing member and 1.5mm thickness for Non Load bearing members with 4mm ISMC Base frame.

-

-

-

... More
The Enclosure shall have IP54 degree of protection for HT and LT switchgear compartment and IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder coated (Color Light Gray and D.A.Gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV and LV compartment. Separate switch operated bulk head lamp for transformer compartment. -_ 1 Set in each INTERCONNECTION AND EARTHING Interconnection Between HT switchgear and Transformer using 1C x 3R x 95 Sq.mm XLPE Single core cable and Interconnection between Transformer and LT switchgear using Aluminium Busbars. Internal earthing connections including transformer neutral by using 50 x 6 mm GI Strips. -_ 1 Set in each WITHOUT GST

-

-

-

... More
NS Item -MAIN LT PANEL Supply and Erection Testing and commissioning of indoor type/OUTDOOR TYPE LT PANEL Confirming specification for cubical panel fabricator out of 2mm thick CRCA sheet having with base frame made M.S sheet duly x with one coat of primer red oxide staving spray painted with one coat of anit corrosion and finally painted synthetic enemal paint of front door powder coated. The panel should be complete in all respect as desired by the Engineer in charge of the work. Make : SIEMENS, SCHNEIDER,UNITECH /ABB/VRINDAVAN/UNITECH ELECTRICALS

1

740000

740000

... More
Incomers 1and 2(CSS-250 KVA ) MCCB 4 pole 400 Aamp., 36 KA with TM Release, Rotary Handle and Spreader Links, 415 volts complete as per above Specs.-02 Sets -_ 02 Sets Shunt Release 220V AC Aux. Block Mechanical and Electrical Interlocking Control MCB 2A SP.10KA `C` Curve. Aux. Contactor Load Manager EM6400NG with RS485 Port or Equivalent (Class 1.0, with RS485 Port, with Paramenters V, Amp, PF, % THD, F,W,WH,VA,VAH, VAR,VARH, Runhrs, ON hrs, Interupts, Make : Schneider / Conzerv / Secure / Siemens MCB 2Amp / SP for Control. Make : Siemens / Legrand / Schneider Indication Lamp LED Type for R, ,Y, B . Make : Siemens / Schneider / LandT LED Lamp 220V for ON / Trip CT`s -Resin Cast CT 800/5 , Make : Kappa, A.E , Meco,NewTek Bus Coupler MCCB 4 pole 400 Aamp., 36 KA with TM Release, Rotary Handle and Spreader Links, 415 volts complete as per above Specs.-02 Sets -_ 01 Set Shunt Release 220V AC Aux. Block Mechanical and Electrical Interlocking Control MCB 2A SP.10KA `C` Curve.

-

-

-

... More
LED Lamp 220V for ON / Trip Outgoing Feeders on Section-1 200A 3P MCCB FEEDER :- (For Meter Board-1,2,3,4 and Spare) -_ 05 Sets 200A 3P 36KA MCCB with Adjustable TM Based Release having O/L,S/C, protections, ROM and Spreader Link. Digital Multifunction Meter Control MCB 2A SP.10KA `C` Curve. CTs 200/5A For Metering CT Shorting Link 100A 3P MCCB FEEDER :- (For Utility) -_ 01 Set 100A 3P 36KA MCCB with Adjustable TM Based Release having O/L,S/C, protections, ROM and Spreader Link. Digital Multifunction Meter Control MCB 2A SP.10KA `C` Curve. CTs 100/5A For Metering CT Shorting Link CT Shorting Link MCB MCB 10 KA 63A 4 Pole -_ 04 Nos MCB 10 KA 63A 4 Pole -_ 04 Nos OUT GOING FEEDERS :- SECTION II

-

-

-

... More
SECTION II 200A 3P MCCB FEEDER :- (For Meter Board- 1,2,3,4 and Spare) -_ 05 Sets 200A 3P 36KA MCCB with Adjustable TM Based Release having O/L,S/C, protections, ROM and Spreader Link. Digital Multifunction Meter Control MCB 2A SP.10KA `C` Curve. CTs 200/5A For Metering CT Shorting Link 100A 3P MCCB FEEDER :- (For Utility) -_ 01 Set 100A 3P 36KA MCCB with Adjustable TM Based Release having O/L,S/C, protections, ROM and Spreader Link. Digital Multifunction Meter Control MCB 2A SP.10KA `C` Curve. CTs 100/5A For Metering CT Shorting Link CT Shorting Link MCB MCB 10 KA 63A 4 Pole -_ 04 Nos MCB 10 KA 63A 4 Pole -_ 04 Nos WITHOUT GST

-

-

-

... More
NS Item -HT VCB PANEL Supply, erection, testing and commissioning of 3 Panel, 800A ,11 kV, 3 Phase, 50 Hz., metal clad, dead front, 500 MVA (26.3 KA) rupturing capacity Vacuum Circuit Breaker 1 No. Incoming and 02 Nos. Outgoings ( 3 Panel Board) as per the detailed specifications and drawings including connections etc. Including interlocking as per technical spcifications and as required. (Make : SIEMENS/SCHNEIDER/ Crompton/ABB) INCOMER: 1 No. VCB Panel having following 1 No. 800A, 11kV, 26.3 KA, 3 Phase, 50Hz., metal clad, dead front, 500 MVA rupturing capacity, Fully Draw out type, Vacuum Circuit Breaker (VCB). 1 set of 11kV/110V -110 V Potential Transformers , Accuracy Class-0.2 for metering and protection. 1 Set of Phase indicating lamps with HRC fuses. 1 No. Digital Voltmeter. 1 set of indicating lamps to indicate OPEN, CLOSE, TRIP, SPRING CHARGED, TRIP CIRCUIT HEALTHY. Push button for ON,

1

1521500

1521500

... More
OFF and TRIP circuit healthy. 1 No. Digital Ammeter with selector switch and one set of C.T 60/5-5 A,Accuracy Class- 0.2 For Measurement and Class 5P10 for Protection. 1 Set of Microcontroller based numerical relay having 4 element relay (3O/C plus 1E/F). Relay should have display of phase current and trip history. Digital Multi Funtion Meter with RS 485.( Accuracy Class -0.2) Digital Tri Vector Meter.( Accuracy Class

-

-

-

... More
I Set of undervoltage relay and Overvoltage relay. Trip circuit supervision relay, Auxiliary relays with shunt trip coil (WTI and Door open trip). I No. Master Trip relay. 1 No. Trip Circuit Supervision Relay 8 window annunciator. 1 no. Phase Reversal Relay. I Set of Undervoltage Relay and Overvoltage Relay. BUSBARS: 11kV, 500 MVA, 800 Amps Three Phase busbars of Aluminium OUTGOINGS: 2 No. VCB each having the following: 1 No. 800A, 11kV, 26.3 KA, 3 Phase, 50Hz., metal clad, dead front, 500 MVA rupturing capacity, Fully Drawout type, Vacuum Circuit Breaker (VCB). 1 set of 11kV/110V-110 V Potential Transformers Accuracy Class -0.5 for metering and protection. 1 Set of Phase indicating lamps with HRC fuses. 1 No. Digital Voltmeter. 1 set of indicating lamps to indicate OPEN, CLOSE, TRIP, SPRING CHARGED, TRIP CIRCUIT HEALTHY. Push button for ON, OFF,TRIPandTRIP circuit healthy. 1 No. Digital Ammeter with selector switch and one set of C.T 30/5-5 A,Accuracy Class-0.5 For Measurement and Class 5P10 for Protection. 1 Set of Microcontroller based numerical relay having 4 element relay (3O/C plus 1E/F). Relay should have display of phase current and trip history. Digital Multi Funtion Meter with RS 485.( Accuracy Class -0.2) Trip Circuit Supervision Relay I No. Master Trip relay. Auxiliary Relays with shunt trip coil (3 C/O - 2 Nos. for Alarm/Trip) 8 window annunciator. WITHOUT GST

-

-

-

... More
NS Item -Supply of prestressed cement concrete (PCC) pole as per IS : 1678-1960, Height 9 metres long 105 mm x 115 mm at top and 105 mm x 315 mm at bottom with working load of 200 kg. burried 1.80 m in ground, as per UHBVN Complete the all necessary connection in all respect.

2

11000

5500

... More
NS Item -Supply of prestressed cement concrete (PCC) pole as per IS : 1678-1960, Height 8 metres long 90 mm x 145 mm at top and 90 mm x 290 mm at bottom with working load of 200 kg burried 1.6 m in ground, as per UHBVN Complete the all necessary connection in all respec

2

8650

4325

... More
NS Item -Supply and erection of 11 KV G.O.D.O. Panel with 25x5 mm size copper bus- bar contacts including suitable M.S. Stand Complete the all necessary connection in all respect.WITHOUT GST

1

40500

40500

... More
NS Item -Supply and installation of fire existingusher ABC type 4 kg capacity duly erected / hangs on the wall with hooks i.c the cost of hook ,screw etc with all material required to complete the job in all respact. WITHOUT GST

4

11648

2912

... More
NS Item -Suply of prestressed cement concrete (PCC) pole as per IS : 1678-1960, Height 11 metres long 152 mm x 203 mm at top and 152 mm x 368 mm at bottomwith working load of 360 kg. burried 2.20 m in ground Complete the all necessary connection in all respect.without GST

2

20120

10060

... More
( B) Part Estate work Total Amount

-

-

-

... More
Street light work

-

-

-

... More
HSR Item 23.3.6.1-COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) HSR Rate(Rs.) 88.00 Through Rate

1000

88000

88

... More
HSR Item 32.70.1-Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 1. Above 1 kWp and up to 10 Kwp HSR Rate(Rs.) 48699.00 Through Rate

10

486990

48699

... More
HSR Item 24.2.4.2-LT CABLE 4.2. Laying of underground cable in pipe /existing open/closed trench etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core HSR Rate(Rs.) 13.00 Through Rate

200

2600

13

... More
NS Item -Supply and erection of Semi Solar Street Light 30 watt Solar Panel 100 Wp-1 nos. LED Light 30 watt philips-1 nos ( Inbuilt Battery LiPo4 36 AH. PWM Charge Controller, PIR Sensosr). Backup Hours 18-20 hours, Lumen 3300, Warrenty : solar panel -25 yrs, LED street light 5 yrs, Battery 5 yrs Complete in all respect.

8

147256

18407

... More
NS Item -Supply of 45 watt LED street Light suitable for operating on 220 V, 50Hz supply complete with making necessary connection. Make - Havells or as per HPHC approved brand list

60

171480

2858

... More
HSR Item 23.27.3-Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 3. M.S. pedestal of size 750 mm wide , 1200 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 HSR Rate(Rs.) 7768.00 Through Rate

1

7768

7768

... More
NS Item -supply of semi Intergrated street Light 20 watt LED Phlips 20 watt. Battery 24 AhliPo4 A class cells. Solar Panel 75 watt PIR Sensor. Dusk and Down. Warranty-5 Years off Site Complete in all respect.

24

418992

17458

... More
HSR Item 24.9.3-RCC FOUNDATIONS FOR HIGH MAST OCTAGONAL POLES 3. Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 75 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for high mast octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 20m high mast pole HSR Rate(Rs.) 71685.00 Through Rate

1

71685

71685

... More
HSR Item 24.4.15.3-STREET LIGHT 15.3. B.S.E.N. 10025 High Masts "Supply, installation, testing and commissioning of 20 mtr. long High Mast manufactured from B.S.E.N. 10025 or equivalent grade material in, 2 (two) section hot dip, galvanized inside and outside in single dip, suitable for wind velocity as per IS 875 Part-3 suitable for 9/12 nos. luminaire loading fully motorized (power tool) with starter & cable complete along with standard accessories supplied by the manufacturer with 3 nos. steel wire rope double drum system and twin dome aviation light with LED without foundation but including cost of set of foundation nut and bolts, installation at site complete in all respect upto entire satisfaction of Engineer -in-Charge Thickness of Top and Bottom Section = 3 mm & 4mm (minimum) Top Dia = 150 mm and Bottom Dia = 460mm Thickness of Galvanization - Top = 65 micron (minimum) and Bottom = 85 micron (minimum)" HSR Rate(Rs.) 203913.00 Through Rate

1

203913

203913

... More
HSR Item 24.4.8.5-STREET LIGHT 8.5. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 7 Metre Long pole with top dia 75 0mm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm HSR Rate(Rs.) 15685.00 Through Rate

50

784250

15685

... More
HSR Item 24.4.3-STREET LIGHT 3. Supply and erection of 32mm dia metre 1.5 m long bracket (B-class) making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing of GI. bracket on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections. HSR Rate(Rs.) 512.00 Through Rate

50

25600

512

... More
HSR Item 24.1.11-EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. HSR Rate(Rs.) 189.00 Through Rate

260

49140

189

... More
HSR Item 24.1.2-EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. HSR Rate(Rs.) 652.00 Through Rate

14

9128

652

... More
HSR Item 24.5.2.1-MISCELLANEOUS ITEMS 2.1. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 40/32 mm outer dia/ inner dia HSR Rate(Rs.) 100.00 Through Rate

100

10000

100

... More
HSR Item 24.5.2.2-MISCELLANEOUS ITEMS 2.2. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 50/40 mm outer dia/ inner dia HSR Rate(Rs.) 109.00 Through Rate

300

32700

109

... More
HSR Item 24.5.2.3-MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia HSR Rate(Rs.) 124.00 Through Rate

100

12400

124

... More
HSR Item 24.1.1-EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. HSR Rate(Rs.) 2721.00 Through Rate

14

38094

2721

... More
HSR Item 23.22.5.3-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE HSR Rate(Rs.) 426.00 Through Rate

3

1278

426

... More
HSR Item 23.27.1-Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 1. M.S. pedestal of size 600 mm wide , 750 mm high ,300 mm deep and bottom totally open , duly embeded in 1:2:4 cement concrete block of size 750 mm x 450 mm x 200 mm above ground level , having a base of size 900 mm x 600 mm x 250 mm below ground level. 0 0 HSR Rate(Rs.) 4854.00 Through Rate

1

4854

4854

... More
HSR Item 23.22.4.4-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.4. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 16 way ( 2 incoming and 14 outgoing) HSR Rate(Rs.) 2080.00 Through Rate

2

4160

2080

... More
HSR Item 23.22.5.7-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.7. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs FOUR POLE HSR Rate(Rs.) 910.00 Through Rate

3

2730

910

... More
HSR Item 24.4.4.2-STREET LIGHT 4.2. Erection of street light fitting on the pole including the cost of petty material required (irrespective of height/length of bracket) At Pole above 4.5 metres but up to the height of 7 metres. HSR Rate(Rs.) 107.00 Through Rate

60

6420

107

... More
HSR Item 24.2.4.1-LT CABLE 4.1. Laying of underground cable in pipe /existing open/closed trench etc as required:- 2.5 Sq mm to 10 Sq mm 2 to 4 Core HSR Rate(Rs.) 9.00 Through Rate

800

7200

9

... More
HSR Item 24.4.7.1-STREET LIGHT 7.1. Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 32 mm dia HSR Rate(Rs.) 280.00 Through Rate

50

14000

280

... More
HSR Item 24.4.7.2-STREET LIGHT 7.2. Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia HSR Rate(Rs.) 385.00 Through Rate

50

19250

385

... More
HSR Item 23.20-Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required HSR Rate(Rs.) 67.00 Through Rate

4

268

67

... More
HSR Item 23.22.5.1-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole HSR Rate(Rs.) 145.00 Through Rate

120

17400

145

... More
NS Item -Supply and erection of Astronomical Multifunction Time Switch for Control Devices and Mounitoring with different switching time internal battery to enable the timing function in case of power failure, daily and weekly programing Make Havells. without GST

1

4870

4870

... More
NS Item -SUPPLY of PVC/ XLPE insulated (Heavy Duty ) Electrical cables for working voltage upto 1100 volt to IS: 1554 (PART-1) with Aluminium Conductor- ISI Marked Power Cable- Aluminium Conductor (10 sqmm 4 core armoured/ unarmoured as per requirment/ enegineer in charge). Make - Grandlay ( price list w.e.f from 24.01.2022) as per HPHC Brand List

150

22500

150

... More
NS Item -Supply and erection of 1.5 sq. mm ISi marked, FRLS PVC insulated, single core copper conductor cable .Make:- as per HPHC approved Brand List without gst

1000

14500

14.5

... More
NS Item -Supply and erection of 4 sq. mm ISi marked, FRLS PVC insulated, single core copper conductor cable .Make:- as per HPHC approved Brand List WITHOUT GST

100

3125

31.25

... More
NS Item -Supply and erection of Post Top lantern 25/ 30 watt LED light suitable for 220 V, 50 Hz supply. Make as per HPHC Brand list

5

28725

5745

... More
NS Item -S/E of 32mm dia metre 1.5 m long Double Arm bracket (B-class) making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing of GI. bracket on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections. without gst

5

8150

1630

... More
NS Item - Supply of 16 Sq. mm 4 Core armoured/ unarmoured as per requirment/ enegineer in charge PVC/ XLPE insulated (Heavy Duty ) Electrical cables for working voltage upto 1100 volt to IS: 1554 (PART-1) with Aluminium Conductor- ISI Marked Power Cable- Aluminium Conductor . Make - Grandlay or as per HPHC approved brand list.

200

34800

174

... More
NS Item -Supply of PVC/ XLPE insulated (Heavy Duty ) Electrical cables for working voltage upto 1100 volt to IS: 1554 (PART-1) with Aluminium Conductor- ISI Marked Power Cable- Aluminium Conductor (6 sqmm 4 core armoured/ unarmoured as per requirment/ enegineer in charge). Make - Grandlay ( price list w.e.f from 24.01.2022) as per HPHC Brand List without gst

600

78000

130

... More
NS Item -S/E of Piller Light of 8`` size Globe with 9 watt rating LED Bulb with 2 years warrenty (Make- Crompton/ Havells or as per HPHC approved brand list) suitable for 220 V, 50 Hz supply with Suitable base for piller light complete with making necessory connections and allied items i.e. nut, bolt, base etc.WITHOUT GST

100

35000

350

... More
NS Item -SITC of IP 65 Photoelectric Cell for use of Standard/ Programable light Sensitive Switched / LDR (Light detecting resistor) with 100 A rating 3 phase Power Connector, 100 A rating MCCB 4 Pole 25kA, Automanual switch, On/ Off Indicator, Terminal Block connetor , Power wiring complete in all respect for automatic light sensitive switching in sun- rise and sun- set.WITHOUT SGT

1

16425

16425

... More
NS Item -S/E of 180/200 watt LED Flood Light suitable for working on 220 V , 50 Hz AC supply, complete with making necessary connection. Make - Havells or as per HPHC approved brand list. without GST

12

88260

7355

... More
NS Item -Supply of 45 watt LED street Light suitable for operating on 220 V, 50Hz supply complete with making necessary connection. Make - Havells or as per HPHC approved brand list. WITHOUT GST

60

163200

2720

... More
Street Light Total ( C Part )

-

-

-

... More
Sub-Component :- Passenger lift work

-

-

-

... More
HSR Item 23.22.1.9-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA HSR Rate(Rs.) 6130.00 Through Rate

12

73560

6130

... More
HSR Item 24.5.2.1-MISCELLANEOUS ITEMS 2.1. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 40/32 mm outer dia/ inner dia HSR Rate(Rs.) 100.00 Through Rate

320

32000

100

... More
HSR Item 23.22.2.1-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP HSR Rate(Rs.) 1815.00 Through Rate

8

14520

1815

... More
HSR Item 23.22.1.11-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA HSR Rate(Rs.) 10809.00 Through Rate

1

10809

10809

... More
HSR Item 23.24.4.1-MS STAND, BUS BAR CHAMBER AND PANELS 4.1. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 4 way 250 amp. HSR Rate(Rs.) 43169.00 Through Rate

1

43169

43169

... More
HSR Item 24.1.3-EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. HSR Rate(Rs.) 3368.00 Through Rate

2

6736

3368

... More
HSR Item 24.1.5-EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. HSR Rate(Rs.) 801.00 Through Rate

2

1602

801

... More
HSR Item 24.1.7-EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. HSR Rate(Rs.) 360.00 Through Rate

30

10800

360

... More
HSR Item 23.22.4.5-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) HSR Rate(Rs.) 2707.00 Through Rate

4

10828

2707

... More
HSR Item 23.22.5.8-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE HSR Rate(Rs.) 1291.00 Through Rate

4

5164

1291

... More
HSR Item 24.1.8-EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. HSR Rate(Rs.) 96.00 Through Rate

40

3840

96

... More
HSR Item 24.5.2.3-MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia HSR Rate(Rs.) 124.00 Through Rate

100

12400

124

... More
HSR Item 24.2.4.3-LT CABLE 4.3. Laying of underground cable in pipe /existing open/closed trench etc as required:- 50 Sq mm to 150 sqmm 2 to 4 Core HSR Rate(Rs.) 21.00 Through Rate

550

11550

21

... More
NS Item -Supply and erection of 1.5 sq. mm ISi marked, FRLS PVC insulated, single core copper conductor cable .Make:- as per HPHC approved Brand List without gst

400

5800

14.5

... More
NS Item -Supply and erection of 4 sq. mm ISi marked, FRLS PVC insulated, single core copper conductor cable .Make:- as per HPHC approved Brand List WITHOUT GST

400

12500

31.25

... More
NS Item -Supply and erection of 10 sq. mm ISi marked, FRLS PVC insulated, single core copper conductor cable .Make:- as per HPHC approved Brand List WITHOUT GST

400

36800

92

... More
NS Item -Supply of PVC/ XLPE insulated (Heavy Duty ) Electrical cables for working voltage upto 1100 volt to IS: 1554 (PART-1) with Aluminium Conductor- ISI Marked Power Cable- Aluminium Conductor (50 sqmm 3.5/ 4 core armoured/ unarmoured as per requirment/ enegineer in charge). Make - Grandlay ( price list w.e.f from 24.01.2022) as per HPHC Brand List

150

53700

358

... More
NS Item -Supply and erection of 6 sq. mm ISi marked, FRLS PVC insulated, single core copper conductor cable .Make:- as per HPHC approved Brand List WITHOUT GST

400

16000

40

... More
NS Item -Supply of PVC/ XLPE insulated (Heavy Duty ) Electrical cables for working voltage upto 1100 volt to IS: 1554 (PART-1) with Aluminium Conductor- ISI Marked Power Cable- Aluminium Conductor (16 sqmm 4 core armoured/ unarmoured as per requirment/ enegineer in charge). Make - Grandlay ( price list w.e.f from 24.01.2022) as per HPHC Brand List without GST

400

73600

184

... More
NS Item -Supply, installation, tesing and commissioning of 884kg/13 passengers, 7storeys (Stilt plus 6), automatic glass door Lift including ARD (Automatic Rescue Device)/ ERD (Emergency rescue device) System of 30 minutes battery back-up complete in all respect as satisfactory of charge - in - engineer. Make - Orbis or as per HPHC approved brand list.without gst

4

7276000

1819000

... More
(D Part ) Total Amount

-

-

-

... More
Sub-Component :- Generator with shed work

-

-

-

... More
HSR Item 23.22.2.1-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP HSR Rate(Rs.) 1815.00 Through Rate

1

1815

1815

... More
HSR Item 24.5.2.4-MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia HSR Rate(Rs.) 161.00 Through Rate

100

16100

161

... More
HSR Item 23.22.1.10-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA HSR Rate(Rs.) 6695.00 Through Rate

1

6695

6695

... More
HSR Item 24.7.2-RCC FOUNDATIONS FOR DG SET 2. 60 to 90 KVA DG Set HSR Rate(Rs.) 22159.00 Through Rate

1

22159

22159

... More
HSR Item 24.1.4-EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. HSR Rate(Rs.) 8275.00 Through Rate

2

16550

8275

... More
HSR Item 24.1.5-EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. HSR Rate(Rs.) 801.00 Through Rate

4

3204

801

... More
HSR Item 24.1.8-EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. HSR Rate(Rs.) 96.00 Through Rate

24

2304

96

... More
HSR Item 24.1.10-EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. HSR Rate(Rs.) 730.00 Through Rate

24

17520

730

... More
HSR Item 20.89.4-`Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. a) Diesel Engine b) Alternator c) Battery 24 V. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) Tools, standard panel g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT`s) h) Metering set 60/5A/110V (Amp. Meter, Volt Meter) i) Overload protection for DC-1 No. j) Battery Charger 24V DC k)Copper bus bar of suitable size l) KWH meter 96 sqmm size m) Starting fuse button and key switch9on/off) n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, Dc control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge` 4. 50 KVA HSR Rate(Rs.) 522763.00 Through Rate

1

522763

522763

... More
HSR Item 9.31-Providing and fixing Hi, Rib profiled sheets 0.60mm TT (Total Thickness) (only ± 0.2mm tolerance allowed) Hi Tensile galvalume/Zincalume steel sheet of the approved make having a hot dip metallic Zinc-Aluminium alloy (AZ-150) coating of minimum (150 gms/sqm) with 550 Mpa yield strength of approved blue colour (RAL-5012) the colour coating shall be as per IS 15965 of SMP or Super Durable Polyester Paint XRW fixed with hex head self-drilling screw sloping roof without curvature as per approved specification, drawing and design of the Corporation HSR Rate(Rs.) 508.00 Through Rate

200

101600

508

... More
HSR Item 13.29.2-Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works HSR Rate(Rs.) 83.00 Through Rate

20

1660

83

... More
HSR Item 13.28-Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. HSR Rate(Rs.) 75.00 Through Rate

1000

75000

75

... More
HSR Item 24.1.7-EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. HSR Rate(Rs.) 360.00 Through Rate

20

7200

360

... More
HSR Item 24.1.9-EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. HSR Rate(Rs.) 730.00 Through Rate

20

14600

730

... More
HSR Item 23.22.8.3-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.3. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 200 amp 415 volts HSR Rate(Rs.) 14959.00 Through Rate

1

14959

14959

... More
HSR Item 24.1.3-EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. HSR Rate(Rs.) 3368.00 Through Rate

2

6736

3368

... More
HSR Item 24.2.4.3-LT CABLE 4.3. Laying of underground cable in pipe /existing open/closed trench etc as required:- 50 Sq mm to 150 sqmm 2 to 4 Core HSR Rate(Rs.) 21.00 Through Rate

220

4620

21

... More
NS Item -Supply of 95 Sq. mm 3.5 Core Armoured PVC/ XLPE insulated (Heavy Duty ) Electrical cables for working voltage upto 1100 volt to IS: 1554 (PART-1) with Aluminium Conductor- ISI Marked Power Cable- Aluminium Conductor . Make - Grandlay or as per HPHC approved brand list.

120

67200

560

... More
NS Item -Supply of LED 18 to 24 watt Square fitting ( 1`x 1`) size , surface / recess. Make:as per HPHC approved brand list

2

4914

2457

... More
NS Item -Supply of 32/34/36 watt 6000k LED Surface/recess Mount fitting, slim type, M.S body 2`x2` size suitable for operation on 230V 50Hz AC Supply Make-Havells or as per HPHC approved brand list WITHOUT GST

2

5460

2730

... More
NS Item -Supply of 70 Sq. mm 3.5 Core Armoured PVC/ XLPE insulated (Heavy Duty ) Electrical cables for working voltage upto 1100 volt to IS: 1554 (PART-1) with Aluminium Conductor- ISI Marked Power Cable- Aluminium Conductor . Make - Grandlay or as per HPHC approved brand list.

100

44800

448



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.