Haryana Police Housing Corporation Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Haryana Police Housing Corporation - HPHC Tender

Works
Building Construction
Eprocure
Opening Date4 Feb 2025
Closing SoonCancelled
Tender Amount₹ 44,89,63,870 
Notes
Download

Costs

  • EMD

    ₹ 89,80,000
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
[10.4]Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. [Through Rate]

7014.85

88

617306.8

... More
[10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate]

3923.59

2707

10621158.13

... More
[10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. [Through Rate]

2862.26

2534

7252966.84

... More
[10.52.1]Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc. [Through Rate]

359.8

2534

911733.2

... More
[10.53.1]Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm, including pointing with white cement slurry admixed with pigment to match the marble shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc. [Through Rate]

53.97

4954

267367.38

... More
[10.55]providing and fixing 38 mm thick wood block flooring of first class teak wood laid over 25 mm thick levelling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete. [Through Rate]

237.32

5145

1221011.4

... More
[10.61]Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. [Through Rate]

302.19

756

228455.64

... More
[10.62]Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. [Through Rate]

361.87

570

206265.9

... More
[10.63.3]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 3. Size of Tile 800x800 mm [Through Rate]

534.19

1164

621797.16

... More
[10.67.3]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 3. Size of Tile 800x800 mm [Through Rate]

80.13

1181

94633.53

... More
[10.7]Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4 [Through Rate]

45

216

9720

... More
[10.70.3]Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 3. Size of Tile 800x800 mm [Through Rate]

573.28

113

64780.64

... More
[11.17]Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge [Through Rate]

15022.96

234

3515372.64

... More
[11.58]Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete [Through Rate]

15014.41

32

480461.12

... More
[11.61.1]White washing with lime to give an even shade : 1. New work (three or more coats) [Through Rate]

3100.96

13

40312.48

... More
[11.64.1]Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer [Through Rate]

15227.37

45

685231.65

... More
[11.73.1]Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer`s specifications including appropriate priming coat, preparation of surface, etc. complete. 1. On steel work [Through Rate]

679

80

54320

... More
[11.82.1]Painting the wooden / metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work [Through Rate]

2132.51

49

104492.99

... More
[11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate]

2896.54

88

254895.52

... More
[12.12.2]Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 2. 1.0 mm thick [Through Rate]

505.2

460

232392

... More
[12.130.3]Providing and fixing of casement and fixed windows made from multi chambered UPVC profiles of 56 to 68mm width in natural from stabilized for heat, light, impact and UV radiation The UPVC profiles should be reinforced with galvanized steel profiles of designed thickness. All openable sashes shall be having weather seal fitted in continuous lengths made from Bubble EPOM Rubber and side hung/ top hung with up to 90 degree opening friction stays of SS 304 with provision of multipoint locking system made from Espag rods. All handle shall be made from Die Cast Zinc alloy (Model ESPAG)BS-1004A in white finish with suitable locking arrangement. The windows shall be fixed to opening using expandable screws and friction stays that shall be able to with stand wind speeds up to 180 km/hr. the shoot bolts in windows shall be rust proof metallic coated steel. The window frames shall be fixed in masonry wall RCC with necessary fasteners, nuts, bolts, washers, caps, silicon sealant etc. complete 3. Double glass glazing comprising of 6 mm thick toughened clear glass + 12mm air gap + 5mm annealed clear glass. [Through Rate]

249.58

1987

495915.46

... More
[12.136.4]Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape and size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) crescent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame and sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware`s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing and direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 4. Three track three panels sliding door with fly proof S.S wire mesh (Two Nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm up to 5.00 sqm) [Through Rate]

249.58

6427

1604050.66

... More
[12.140]Providing and fixing steel roller for uPVC sliding window with necessary screws etc. complete. [Through Rate]

516

71

36636

... More
[12.142]Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. complete. [Through Rate]

129

139

17931

... More
[12.171]Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). [Through Rate]

278.34

3415

950531.1

... More
[12.36.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate]

252.6

2385

602451

... More
[12.80]Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. [Through Rate]

30

541

16230

... More
[13.20]Providing and Fixing Poly Carbonate Sheet 1.25mm thickness on Gates and grills excluding the cost of MS framework but including the cost of nut bolts, Welding rods complete in all respect as per direction of Engineer­in-Charge. [Through Rate]

582.68

1310

763310.8

... More
[13.21.1]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 1. Door Frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter [Through Rate]

546.85

947

517866.95

... More
[13.28]Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. [Through Rate]

3055.5

75

229162.5

... More
[13.30.1]Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 1. Hot finished welded type tubes [Through Rate]

817913.1

105

85880875.5

... More
[13.37.1]Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 1. 80x1.25 mm M.S. laths with 1.25 mm thick top cover [Through Rate]

62.63

1993

124821.59

... More
[13.38]Providing and fixing ball bearing for rolling shutters. [Through Rate]

8

322

2576

... More
[13.39.1]Extra for providing mechanical device chain and crank operation for operating rolling shutters. 1. Exceeding 10.00 sqm and up to 16.80 sqm in the area [Through Rate]

62.63

938

58746.94

... More
[13.4.1]Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) [Through Rate]

530.4

100

53040

... More
[13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate]

6694.3

396

2650942.8

... More
[13.6.1]Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 1. Using M.S. angels 40x40x6 mm for diagonal braces [Through Rate]

48

2738

131424

... More
[13.9.2]Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3 mm and nuts and bolts complete. 2. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides [Through Rate]

124.79

697

86978.63

... More
[17.14.1]Granular Sub-Base with Close Graded Material - (Table:- 400-1) Plant mix method Construction of granular sub-base by providing Material as per Grading III (Table 400-I of MORTandH 5th revision) mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORTandH specifications 1. Grading I material [Through Rate]

233.99

1178

275640.22

... More
[17.14.2]Granular Sub-Base with Close Graded Material - (Table:- 400-1) Plant mix method Construction of granular sub-base by providing Material as per Grading III (Table 400-I of MORTandH 5th revision) mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORTandH specifications 2. Grading II material [Through Rate]

233.99

1187

277746.13

... More
[17.5.3]Compacting Original Ground 3. Compaction of Earthwork Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications [Through Rate]

2339.88

7

16379.16

... More
[17.69.2]Interlocking Concrete Block Pavement 2. Providing and Laying 80 mm thick ISI marked Interlocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect. [Through Rate]

569.85

655

373251.75

... More
[17.72]Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORTH specifications [Through Rate]

975

4932

4808700

... More
[18.25]Providing and fixing factory made solid Foam uPVC profile for kitchen cabinet frame (45 x 20 mm) of approved shade, quality and make. The profile shall be laminated on both sides, made from rigid foam sheets (Single extruded) having density 600 kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frame shall be fire retardant with necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastener with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. [Through Rate]

882.85

287

253377.95

... More
[18.26]Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardant having necessary screw holding capacity. Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. [Through Rate]

57.69

3214

185415.66

... More
[20.114.3]Supplying erection, testing of fully automatic electric control panel board for T/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of 0 to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in all respect. 3. 20 HP Motor [Through Rate]

2

23190

46380

... More
[20.52.5]providing and placing in horizontal layers filtering media screened washed and cleaned as described below - 5. Bottom layer Broken stone, screened, washed and graded from 50 mm to 75 mm (from Ghaggar or approved equivalent quarry) [Through Rate]

20

1160

23200

... More
[20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48" (1200mm) [Through Rate]

125

2054

256750

... More
[20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. [Through Rate]

23

1339

30797

... More
[20.84]Providing and fixing of insulated rubber matting suitable for 11 KV installation 1 M x 2 M x 12 mm thick (IS code 15652-40091) as per specification complete and as per directions of Engineer-in-charge [Through Rate]

32

1368

43776

... More
[20.85.2]Supplying and Fixing of PVC water bars for water stops flexible physical plastic for preventing leakage in concrete joints to avoid seepage ( Fixo- stop) with ribs and central bulbs marked as per IS-12200 of 2001 along with bitumen filler complete in all respects. 2. 150mm wide X 6.00 mm thickness of wall [Through Rate]

314.48

205

64468.4

... More
[20.86]Supply, erection, testing and commissioning of G.O. Switch two poles, with blade, pin 6 insulators operating handle with GI pipe 25 mm class B complete in all respects. [Through Rate]

2

36814

73628

... More
[21.110.14]Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 30.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect 14. Discharge Capacity (LPM) - 700 Power Capacity (BHP) - 7.5 [Through Rate]

2

82557

165114

... More
[21.28]Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge [Through Rate]

160

298

47680

... More
[21.43]Extra over the rate laid down in this schedule for cement concrete work more making and finishing benching and complicated floor work in manholes, including formation of channels and bulldozing and smooth finishing the surface accurately to template. [Through Rate]

24

160

3840

... More
[21.84.1]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 1. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping [Through Rate]

61

3487

212707

... More
[21.84.2]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 2. Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) [Through Rate]

20

4977

99540

... More
[21.84.3]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) [Through Rate]

15

5438

81570

... More
[21.85.1]Extra for every 0.30 metre depth of Inspection chamber 1. 450 mm x 450 mm inside [Through Rate]

61

762

46482

... More
[21.85.2]Extra for every 0.30 metre depth of Inspection chamber 2. 450 mmx 600 mm inside [Through Rate]

20

847

16940

... More
[21.85.3]Extra for every 0.30 metre depth of Inspection chamber 3. 600 mm x 900 mm inside [Through Rate]

15

1138

17070

... More
[22.10.2.2]Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 2.2. Kitchen sink without drain board610x460 mm bowl depth 200 mm [Through Rate]

10

1924

19240

... More
[22.101.2.1]Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore [Through Rate]

72

51

3672

... More
[22.103.2]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 2. 20 mm nominal bore [Through Rate]

6

294

1764

... More
[22.103.3]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore [Through Rate]

2

292

584

... More
[22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate]

34

346

11764

... More
[22.106.1]Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore [Through Rate]

42

457

19194

... More
[22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate]

118

444

52392

... More
[22.109]Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. [Through Rate]

118

49

5782

... More
[22.110.1]Providing and fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 1. 15 mm nominal bore [Through Rate]

36

6731

242316

... More
[22.119.2]Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 2. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. [Through Rate]

36

360

12960

... More
[22.14.2.1]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 2.1. Flexible pipe 32 mm dia [Through Rate]

46

57

2622

... More
[22.15]Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge. [Through Rate]

46

735

33810

... More
[22.166.1.1]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.1. 100x100 mm size P type With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]

60

1457

87420

... More
[22.19]Providing and fixing 100 mm sand cast Iron grating for gully trap. [Through Rate]

30

32

960

... More
[22.192.1.1]Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.1. 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]

10

5867

58670

... More
[22.194.1.1]Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.1. 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]

10

11121

111210

... More
[22.195.1]Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m : 1. With common burnt clay non-modular bricks of class designation 7.5 [Through Rate]

20

4515

90300

... More
[22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. [Through Rate]

20

813

16260

... More
[22.211]Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. [Through Rate]

20

523

10460

... More
[22.216.1]Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-in-charge. 1. 25 Litres capacity [Through Rate]

10

8086

80860

... More
[22.216.3]Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-in-charge. 3. 35 Litres capacity [Through Rate]

18

10405

187290

... More
[22.221.11]Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. 11. Table Top (size 49 x 40 x 15 cm) [Through Rate]

16

7474

119584

... More
[22.221.9]Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. 9. Size 560mm x 450mm (Under counter oval) [Through Rate]

20

2359

47180

... More
[22.222.2.1]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete [Through Rate]

1020

534

544680

... More
[22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete [Through Rate]

2360

322

759920

... More
[22.33]Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. [Through Rate]

36

10809

389124

... More
[22.38]Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. [Through Rate]

36

241

8676

... More
[22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass [Through Rate]

36

389

14004

... More
[22.46]Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water (250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. [Through Rate]

18

5548

99864

... More
[22.50.1.1.2]Providing and fixing partitions for different type of urinals. 1.1.2. Vitreous Chinaware Partition plate. Small size 680mm x 330 mm Single Colour [Through Rate]

36

1062

38232

... More
[22.85.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate]

57.1

233

13304.3

... More
[22.85.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes [Through Rate]

40.9

311

12719.9

... More
[22.85.5]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 5. 40 mm nominal outer dia Pipes [Through Rate]

37.1

430

15953

... More
[22.86.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes [Through Rate]

1101.9

264

290901.6

... More
[22.87.6]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 6. 50 mm nominal outer dia Pipes [Through Rate]

123

592

72816

... More
[22.87.8]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 8. 75 mm nominal inner dia Pipes [Through Rate]

270

1582

427140

... More
[22.87.9]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 9. 100 mm nominal inner dia Pipes [Through Rate]

75

2256

169200

... More
[22.98.3]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore. [Through Rate]

21

485

10185

... More
[22.98.4]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 4. 40 mm nominal bore [Through Rate]

21

567

11907

... More
[22.98.7]Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 7. 80 mm nominal bore [Through Rate]

8

1892

15136

... More
[22.99.4.2]Providing and fixing gun metal non- return valve of approved quality (screwed end) : 4.2. 50 mm nominal bore Vertical [Through Rate]

8

1057

8456

... More
[23.1.6.2]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.2. Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) [Through Rate]

4525

163

737575

... More
[23.1.6.3]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.3. Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate]

1600

194

310400

... More
[23.1.6.4]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.4. Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate]

2160

238

514080

... More
[23.1.6.5]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.5. Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate]

470

411

193170

... More
[23.2.1.2]COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B [Through Rate]

1106

747

826182

... More
[23.2.2.2]COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) 2.2. Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group B [Through Rate]

52

1062

55224

... More
[23.2.4.2]COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) 4.2. Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B [Through Rate]

138

1179

162702

... More
[23.2.5.2]COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) 5.2. Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B [Through Rate]

71

1494

106074

... More
[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA [Through Rate]

2

20350

40700

... More
[23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA [Through Rate]

16

8577

137232

... More
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate]

11

6130

67430

... More
[23.22.4.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.11. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate]

2

8083

16166

... More
[23.22.4.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.3. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 12 way ( 2 incoming and 10 outgoing) [Through Rate]

3

1706

5118

... More
[23.22.4.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) [Through Rate]

18

2707

48726

... More
[23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate]

6

3958

23748

... More
[23.22.4.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.8. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing) [Through Rate]

2

5755

11510

... More
[23.22.4.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.9. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing) [Through Rate]

10

6088

60880

... More
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]

348

145

50460

... More
[23.22.5.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.2. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Single Pole [Through Rate]

8

308

2464

... More
[23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate]

24

426

10224

... More
[23.22.6.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.1. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 25 A [Through Rate]

3

1478

4434

... More
[23.22.6.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.4. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TP RCCB 30ma sensitivity , 25 A [Through Rate]

16

1950

31200

... More
[23.22.6.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.5. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. FP RCCB 30ma sensitivity , 40 A [Through Rate]

13

1958

25454

... More
[23.22.8.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.5. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 400 amp 415 volts [Through Rate]

2

31366

62732

... More
[23.23.10]MISCELLANEOUS 10. Supplying and drawing of 1 no UTP 4 pair CAT 6a LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate]

14700

44

646800

... More
[23.23.2.1]MISCELLANEOUS 2.1. Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia [Through Rate]

156.25

135

21093.75

... More
[23.23.5.4]MISCELLANEOUS 5.4. Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work. 50x50 mm [Through Rate]

1600

76

121600

... More
[23.23.6.1]MISCELLANEOUS 6.1. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 100 X 50 X 2 mm [Through Rate]

195

231

45045

... More
[23.23.6.3]MISCELLANEOUS 6.3. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 375 X 50 X 2 mm [Through Rate]

45

397

17865

... More
[23.23.6.4]MISCELLANEOUS 6.4. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 600 X 50 X 2 mm [Through Rate]

500

474

237000

... More
[23.23.7.1]MISCELLANEOUS 7.1. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 100 X 50 X 2 mm [Through Rate]

620

203

125860

... More
[23.23.7.2]MISCELLANEOUS 7.2. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 200 X 50 X 2 mm [Through Rate]

490

340

166600

... More
[23.23.7.3]MISCELLANEOUS 7.3. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 375 X 50 X 2 mm metre [Through Rate]

295

588

173460

... More
[23.23.7.4]MISCELLANEOUS 7.4. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 600 X 50 X 2 mm [Through Rate]

500

985

492500

... More
[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate]

1830

31

56730

... More
[23.24.1]MS STAND, BUS BAR CHAMBER AND PANELS 1. Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. [Through Rate]

2025

84

170100

... More
[23.24.4.4]MS STAND, BUS BAR CHAMBER AND PANELS 4.4. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 8 way 400 amp. [Through Rate]

2

56621

113242

... More
[23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. [Through Rate]

6

93

558

... More
[23.26.3]SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame. [Through Rate]

51

262

13362

... More
[23.26.4]SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia). [Through Rate]

6

2739

16434

... More
[23.6.6.1]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia. [Through Rate]

4315

92

396980

... More
[23.6.6.2]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 25 mm dia. [Through Rate]

5128

106

543568

... More
[23.7.6.1]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia. [Through Rate]

6940

26

180440

... More
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]

20200

32

646400

... More
[23.8.1.6]FITTING AND ACCESSORIES 1.6. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Call bell 220/230 volts musical type [Through Rate]

12

90

1080

... More
[23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate]

30

93

2790

... More
[23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate [Through Rate]

280

18

5040

... More
[23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate]

125

257

32125

... More
[23.8.11.8]FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type [Through Rate]

12

75

900

... More
[23.8.11.9]FITTING AND ACCESSORIES 11.9. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. T.V. Socket outlet modular type [Through Rate]

10

75

750

... More
[23.8.3.4]FITTING AND ACCESSORIES 3.4. Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet as below 200 mm X 150 mm X 60 mm deep metal box [Through Rate]

23

158

3634

... More
[23.8.3.5]FITTING AND ACCESSORIES 3.5. Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet as below 200 mm X 150 mm X 60 mm deep metal box [Through Rate]

25

232

5800

... More
[23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. [Through Rate]

125

95

11875

... More
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]

62

2721

168702

... More
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]

190

730

138700

... More
[24.1.11]EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. [Through Rate]

240

189

45360

... More
[24.1.12]EARTHING AND LIGHTENING ARRESTOR 12. Supplying and laying 6 S.W.G G.I. wire at 0.50 m below ground level from earth electrode including thimbles, soldering etc. as required. [Through Rate]

200

127

25400

... More
[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate]

240

21

5040

... More
[24.1.14]EARTHING AND LIGHTENING ARRESTOR 14. Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size. [Through Rate]

250

62

15500

... More
[24.1.16]EARTHING AND LIGHTENING ARRESTOR 16. Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers. [Through Rate]

12

898

10776

... More
[24.1.17]EARTHING AND LIGHTENING ARRESTOR 17. Providing and fixing testing joints made of 20mm x 3mm thick G.I. strips 125 mm long with 4 nos. G.I. bolts and nuts with washers complete. [Through Rate]

60

73

4380

... More
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]

62

652

40424

... More
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate]

20

3368

67360

... More
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate]

16

8275

132400

... More
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate]

36

801

28836

... More
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate]

867

360

312120

... More
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]

1650

96

158400

... More
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. [Through Rate]

154

730

112420

... More
[24.13.100]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 100. 400 Sq mm 3.5 core (Arm.) [Through Rate]

220

2006

441320

... More
[24.13.14]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 14. 10 Sq mm 2core (Arm.) [Through Rate]

215

122

26230

... More
[24.13.18]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 18. 10 Sq mm 4 core (Arm.) [Through Rate]

200

148

29600

... More
[24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate]

250

180

45000

... More
[24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) [Through Rate]

450

217

97650

... More
[24.13.48]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 48. 50 Sq mm 4 core (Arm.) [Through Rate]

880

371

326480

... More
[24.13.56]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 56. 70 Sq mm 4 core (Arm.) [Through Rate]

550

497

273350

... More
[24.13.64]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 64. 95 Sq mm 4 core (Arm.) [Through Rate]

390

624

243360

... More
[24.13.70]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 70. 120 Sq mm 3.5 core (Arm.) [Through Rate]

250

684

171000

... More
[24.13.82]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 82. 185 Sq mm 3.5 core (Arm.) [Through Rate]

480

1011

485280

... More
[24.13.88]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 88. 240 Sq mm 3.5 core (Arm.) [Through Rate]

220

1289

283580

... More
[24.13.94]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 94. 300 Sq mm 3.5 core (Arm.) [Through Rate]

320

1574

503680

... More
[24.14.100]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 100. 400 Sq mm 3.5 core (Arm.) [Through Rate]

4

1988

7952

... More
[24.14.14]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 14. 10 Sq mm 2core (Arm.) [Through Rate]

215

125

26875

... More
[24.14.18]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 18. 10 Sq mm 4 core (Arm.) [Through Rate]

407

151

61457

... More
[24.14.30]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 30. 25 Sq mm 3.5 core (Arm.) [Through Rate]

150

214

32100

... More
[24.14.38]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35 Sq mm 3.5 core (Arm.) [Through Rate]

260

259

67340

... More
[24.14.54]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 54. 70 Sq mm 3.5 core (Arm.) [Through Rate]

300

463

138900

... More
[24.14.56]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 56. 70 Sq mm 4 core (Arm.) [Through Rate]

645

507

327015

... More
[24.14.88]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 88. 240 Sq mm 3.5 core (Arm.) [Through Rate]

400

1303

521200

... More
[24.14.94]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 94. 300 Sq mm 3.5 core (Arm.) [Through Rate]

650

1592

1034800

... More
[24.15.9]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in 1 per meter below ground level with sand and bricks with all labour and material including digging and refilling of trench as required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 9. 300 Sq mm 3 core [Through Rate]

850

2249

1911650

... More
[24.16.9]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 9. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 300 Sq mm 3 core [Through Rate]

150

2149

322350

... More
[24.2.10]LT CABLE 10. Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S. Rod welded/riveted at the top with 10 cm dia 3 mm thick MS plate inscribed with cable word on it, having a cross arm 30 cm long of the same dia welded at the bottom, in exiting trench 45 cm below ground level. [Through Rate]

20

240

4800

... More
[24.2.7.2]LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core [Through Rate]

100

45

4500

... More
[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core [Through Rate]

88

77

6776

... More
[24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core [Through Rate]

32

133

4256

... More
[24.2.7.6]LT CABLE 7.6. Supply and erection of suitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 Core [Through Rate]

64

165

10560

... More
[24.2.7.7]LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core [Through Rate]

80

227

18160

... More
[24.2.8.10]LT CABLE 8.10. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 120 sqmm [Through Rate]

160

32

5120

... More
[24.2.8.12]LT CABLE 8.12. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 185 sqmm [Through Rate]

165

49

8085

... More
[24.2.8.13]LT CABLE 8.13. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 240 sqmm [Through Rate]

48

71

3408

... More
[24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm [Through Rate]

8

91

728

... More
[24.2.8.15]LT CABLE 8.15. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 400 sqmm [Through Rate]

88

125

11000

... More
[24.2.8.3]LT CABLE 8.3. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 10 sqmm [Through Rate]

100

6

600

... More
[24.2.8.5]LT CABLE 8.5. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 25 sqmm [Through Rate]

56

10

560

... More
[24.2.8.6]LT CABLE 8.6. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 35 sqmm [Through Rate]

32

11

352

... More
[24.2.8.8]LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm [Through Rate]

50

20

1000

... More
[24.2.9.6]LT CABLE 9.6. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 70 sqmm to 150 sqmm Cable 3 to 4 Core [Through Rate]

4

3662

14648

... More
[24.2.9.8]LT CABLE 9.8. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 400 sqmm Cable 3 to 4 core [Through Rate]

4

7119

28476

... More
[24.3.3.3]HT CABLE 3.3. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 to 400 sqmm [Through Rate]

8

10280

82240

... More
[24.3.4.3]HT CABLE 4.3. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240 to 400 sqmm [Through Rate]

4

17536

70144

... More
[24.3.5.4]HT CABLE 5.4. Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 to 400 sqmm [Through Rate]

4

38374

153496

... More
[24.4.11.1]STREET LIGHT 11.1. Erection of MS/GI/Swaged ( excluding Octagonal ) metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 2.5 metre and up to 4 metre [Through Rate]

13

527

6851

... More
[24.4.2.4]STREET LIGHT 2.4. Supply and erection of GI bracket made of 32 mm dia medium class GI pipe, having 15 deg angle from horizontal, suitable for fixing on top of Street Light pole 150 cm long, with 30 cm high suitable size pole cap. [Through Rate]

9

685

6165

... More
[24.4.8.7]STREET LIGHT 8.7. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 9 Metre Long pole with top dia 100 mm and bottom 200 mm with base plate of size 350 x 350 x 20 mm. [Through Rate]

6

25028

150168

... More
[24.5.1.1]MISCELLANEOUS ITEMS 1.1. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. Submersible Copper Cable 3 Core 1.5 sqmm [Through Rate]

570

51

29070

... More
[24.5.1.4]MISCELLANEOUS ITEMS 1.4. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. Submersible Copper Cable 3 Core 6 sqmm [Through Rate]

140

143

20020

... More
[24.5.1.6]MISCELLANEOUS ITEMS 1.6. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. Submersible Copper Cable 3 Core 16 sqmm [Through Rate]

120

281

33720

... More
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]

1533

124

190092

... More
[24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate]

1200

161

193200

... More
[24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia [Through Rate]

350

241

84350

... More
[24.5.2.6]MISCELLANEOUS ITEMS 2.6. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 145/123 mm outer dia/ inner dia [Through Rate]

250

297

74250

... More
[24.5.2.7]MISCELLANEOUS ITEMS 2.7. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 180/150 mm outer dia/ inner dia [Through Rate]

1995

343

684285

... More
[24.7.7]RCC FOUNDATIONS FOR DG SET 7. 500 KVA DG Set [Through Rate]

2

97639

195278

... More
[25.3.2]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 2. 250 mm dia [Through Rate]

2

15015

30030

... More
[25.3.3]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 3. 200mm dia. [Through Rate]

3

8941

26823

... More
[25.3.4]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 4. 150mm dia. [Through Rate]

13

4552

59176

... More
[25.3.6]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 6. 100mm dia. [Through Rate]

20

2664

53280

... More
[25.3.7]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 7. 80mm dia. [Through Rate]

13

2030

26390

... More
[25.3.9]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 9. 50 mm dia. [Through Rate]

4

1585

6340

... More
[25.4.2]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 2. 150mm dia. [Through Rate]

6

8137

48822

... More
[25.4.4]Supplying, fixing, testing and commissioning o NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end and PN 16 pressure rating as specified. 4. 100mm dia. [Through Rate]

5

4176

20880

... More
[25.5.2]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 2. 150mm dia. [Through Rate]

6

18147

108882

... More
[25.5.4]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 4. 100mm dia. [Through Rate]

20

9493

189860

... More
[25.5.5]Supplying, fixing, testing and commissioning o BALANCING VALVE flanged end and PN 16 pressure rating as specified. 5. 80mm dia. [Through Rate]

4

6408

25632

... More
[25.7.1]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 1. Thickness 0.63 mm sheet [Through Rate]

162

812

131544

... More
[25.7.2]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 2. Thickness 0.80 mm sheet [Through Rate]

1984.44

972

1928875.68

... More
[25.7.3]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 3. Thickness 1.00 mm sheet [Through Rate]

1125

1175

1321875

... More
[25.7.4]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 4. Thickness 1.25 mm sheet [Through Rate]

75

1398

104850

... More
[26.1]Supplying and stacking at site of work well-decayed farm-yard manure from any available source, approved by the Engineer-in-charge including screening through sieve of I.S.designation 16 mm with 5 km lead. [Through Rate]

115.05

546

62817.3

... More
[26.10]Maintenance of fine grass lawn for one year including fertilizer application, DAP @ 20gm/sqm, urea 40gm/sqm, watering, weeding, top dressing with good earth and manure mixture 2:1 @ 0.01cum per sqm, maintaining fine level, regular mowing and removal of rubbish with all lifts and leads. [Through Rate]

575.25

45

25886.25

... More
[26.13.3]Digging holes in all kinds of soil, and refilling the same, with the excavated earth, mixed with well decayed farmyard manure (cost of well decayed farm yard manure to be paid separately) 3. Hole 0.75 metre dia and 0.75 metre deep [Through Rate]

185

21

3885

... More
[26.13.4]Digging holes in all kinds of soil, and refilling the same, with the excavated earth, mixed with well decayed farmyard manure (cost of well decayed farm yard manure to be paid separately) 4. Hole 0.60 metre dia and 0.60 metre deep [Through Rate]

127

11

1397

... More
[26.2]Supplying and stacking of good quality top layer garden earth free from debris and weeds, at site including royalty and carriage/lead 5 km (good earth measured in stacks will be reduced by 20 % for payment) only for filling of pots and flower beds . 0.00 0.00 0.00 [Through Rate]

345.15

302

104235.3

... More
[26.20]Supply and Planting rare and specimen tree plants in already prepared pits (Ficus starlight 150 cm height , Terminalia 210 cm height, menatalis , Michelia champaca hybrid more than 180 cm height, Cyprus (Golden juniperous ) more than 180 cm height, topiary of 10 to 12 no. well trimmed bolls of more than 30cm size of Ficus nuda, Ficus retusa, Ficus long island , Ficus panda more than 180 cm height, Golden bottle brush , casurina equistefolia , Bottle palm with stem circumference at base more than 40cm ,Washingtonia palm of healthy clear stem height below leaf more Thant 90 cm ) including , fertilizer and insecticides chlorpyriphos 20 ml per pit, planting of 180cm to 210cm tall sapling in position and flooding with water .specie of plant will be decided by engineer in charge. [Through Rate]

185

999

184815

... More
[26.21]Maintenance of specimen tree for one year including weeding, hoeing , plant protection , watering from Deptt. source , application of 20 ml chlorpyriphos four times, 0.0289 cum FYM each,50 gm urea and 50 gm DAP twice ,replacement of casualty ,disposal of debris and other activities.etc. [Through Rate]

185

582

107670

... More
[26.22.1]Planting seasonal flower in beds 1. Supply and planting flower beds including digging 30 cm deep bed and refilling of beds with excavated soil and FYM 0.0508 cum per sqm , Fertilizer DAP 50 gms and insecticides chlorpyriphos 10 ml per sqm , planting of F1 hybrid flower saplings to be supplied in tray pots / thumb pots at 20 cm distance from plant to plant and row to row minimum 25 no . plants per sqm [Through Rate]

125

213

26625

... More
[26.24]Supply and planting bulbous flower of football lily, amaryllis lily , Lilium, gladiolus, Cladium of hybrid colour vise beds including digging 30 cm deep bed and refilling of beds with excavated soil and FYM 0.0508 cum per sqm , Fertilizer DAP 50 gms and insecticides chlorpyriphos 10 ml per sqm , planting of bold size flower bulbs of improved cultivars to be supplied and planted at 23 cm distance from plant to plant and row to row minimum 18 no . bulbs per sqm [Through Rate]

98

396

38808

... More
[26.30]Supplying healthy, well branched, well bloomed and Planting rose beds including digging 30 cm deep bed and refilling of beds with excavated soil and FYM 0.0508 cum per sqm , Fertilizer DAP 50 gms and insecticides chlorpyriphos 10ml per sqm , planting of hybrid Budded rose saplings to be supplied in earthen pots /20cm x20cm polybags , planting of sapling at 45 cm distance from plant to plant and row to row and 5 no. plants per sqm [Through Rate]

64.03

159

10180.77

... More
[26.32]Planting permanent edging plants around beds, lawn or along paths including of digging of trench 45 cm wide to 15 cm depth, refilling the excavated earth, mixed with farm-yard manure, supplied at the rate of 0.9 cum per sqm and supplying and planting hedge/ edge at 20 cm apart in one or two rows @11no. well trimmed bushy ,multi branched ,30 cm to 45 cm in height plants to be supplied in 15 cm x 15 cm poly bags per sqm . [Through Rate]

245

97

23765

... More
[26.46]`Supplying and display specimen pot plant of raphis palm , cephorthia palm 150 cm,areca palm 150-180 cm and similar high quality plants of croton petra 3 plants each in 45 cm plastic pots with plastic plate for indoor display at site of work. with fresh foliage,90 cm- 180 cm in height` 6-8 stems per pot, full of leaves, ,and displaying indoor including the cost of material ( garden soil, coco peat, FYM in 2:1:1 proportion),with ,PVC plate. complete in all respects.` [Through Rate]

105

790

82950

... More
[26.50]Supplying and display of specimen pot plant of Cyprus , Ficus starlight, Topiary of Ficus retusa and similar high quality plants in 45 cm cement pots with plastic plate for outdoor display at site of work. with fresh foliage,105 cm- 150 cm in height, 3-4 stems per pot, full of leaves, ,and displaying indoor including the cost of material ( garden soil, coco peat, FYM in 2:1:1 proportion),with ,PVC plate. complete in all respects. [Through Rate]

200

803

160600

... More
[26.63.2]Providing and fixing steel tree guard 2. MS circular tree guard with wire mesh, having 4 No. legs of angle iron size 25x25x3mm, 1.80 metre. height, 3 No rings of M.S Flats of 25 x 6 mm, 60cm dia and fixing of wire mesh size 50x75mm. Tree guard in two halves bolted together with 8mm dia & 30 mm long bolts, and fixing 250 mm X 100 mm iron plate, fixed in ground with 1:2:4 cement concrete, complete in all respects. Minimum weight should be 23 kgs [Through Rate]

312

1828

570336

... More
[26.9.4]Turfing lawns with fine grassing ( selection no.1/ Bermuda and Mexican/Neelgiri grass )including ploughing, dressing including breaking of clods, removal of rubbish, dressing and supplying of selection no. 1 / Bermuda doob grass and Mexican/Neelgiri grass roots, including supplying and spreading of farmyard manure at the rate of 0.60 cum per 100 sqm, maintenance till weed free turf is formed 4. Providing and fixing Selection no. 1 grass turf with earth 50mm to 60mm thickness and ramming with required wooden tools, rolling with light roller to make the surface smooth and even [Through Rate]

575.25

100

57525

... More
[28.12]`Providing and applying waterproofing treatment to sound, moisture free concrete surface using liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2 mm. It shall be applied in two coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties: 1) Elongation : )400% as per ASTM D 412 2) Tensile Strength : 2.5 N/mm2 as per ASTM D 412 3) Adhesion in-peel test : )50 N as per ASTM C- 836 4) Recovery from 350% elongation : 95% as per ASTM D 412 5) Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr 6) Initial Hardness Shore A : min 60 as per ASTM D 2240 7) Root resistant : protection screed required System includes supply , application and termination of coating all complete as per the manufacturer methodology. Clean the RCC slab/screed surface and wall for treatment by removing dust, dirt and layers of concrete over the surface. etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer’s recommendations. Providing and applying liquid applied single component pitch free polyurethane coating in 2 coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. (Fibre cloth/fleece/reinforcement should not be used in between two coats of PU as it has adverse effect on elongation property and also affects bonding with slab). Termination shall be done 300 mm above vertical wall by providing a groove cut of 30mm x 30mm and seal it with shrinkage compensated polymer modified mortar. Membrane shall be protected using 8mm thick dimple board for protection as per manufacturer`s recommendation followed by backfilling. The rates are inclusive of surface preparation, crack filling, injection grouting at honeycombed areas, coving, priming all complete as per manufacturer methodology but excluding the cost of protection board. ` [Through Rate]

3762.66

719

2705352.54

... More
[28.15]Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. [Through Rate]

1305.35

233

304146.55

... More
[28.17.1]Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 1. With average thickness of 120 mm and minimum thickness at khurra as 65 mm. [Through Rate]

2296.25

664

1524710

... More
[28.20.1]Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage and water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 1. For vertical surface two coats @ 0.70 kg per sqm [Through Rate]

3762.66

398

1497538.68

... More
[28.8]`Supplying and applying waterproofing treatment for `Raft Slab` by using 1.2 mm thick fully bonded HDPE sheet membrane complying to BS8102:2009/ IS 16471-2017. The HDPE shall be virgin HDPE and not recycled, thickness of bare HDPE shall not be less than 0.8 mm coated with pressure sensitive adhesive layer and a trafficable granular top layer. The HDPE membrane shall have the following typical properties: 1. Tensile Strength : )27 Mpa ( as per ASTM D412) 2. Puncture Resistance: )1000N±5% (as per ASTM E154) 3. Elongation: )500% 4. Peel adhesion to concrete: )1500N/m (as per ASTM D903 Modified) 5. Resistance to Hydrostatic Head: )70 metre (as per ASTM D751-06(2011) 6. UV exposure test (60 days): No change 7. Lap Joint Strength : 1500N/m (as per ASTM D1876) HDPE Membrane shall be installed over the entire PCC area with standard 75 mm selvedge laps and end laps overlaid with HDPE Sealed Tape as per manufacturer`s instructions. The rates are inclusive of supply and installation of membrane as per manufacturer methodology. The rates are inclusive of surface preparation, injection grouting at honeycombed areas all complete as per manufacturer methodology. ` [Through Rate]

4546.23

656

2982326.88

... More
[3.1.2]By Mechanical Transport including loading, unloading and stacking 2. Earth [1km]

16169.65

53

856991.45

... More
[30.82.1]Making holes by cutting cores of appropriate dia in RCC floors and roofs of thickness up to 6` (six inches) for passing drain pipe and repairing the hole after insertion of drain pipe etc. including finishing-complete so as to make it leak proof. 1. Drain pipe of 150mm internal dia [Through Rate]

44

997

43868

... More
[30.82.2]Making holes by cutting cores of appropriate dia in RCC floors and roofs of thickness up to 6` (six inches) for passing drain pipe and repairing the hole after insertion of drain pipe etc. including finishing-complete so as to make it leak proof. 2. Drain pipe of 100mm internal dia [Through Rate]

222

684

151848

... More
[32.70.3]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 3. Above 100 kWp and up to 500 Kwp [Through Rate]

130

40003

5200390

... More
[33.12]Supplying, filling, spreading and levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. [Through Rate]

42.39

1039

44043.21

... More
[33.13]Supplying, filling, spreading and levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge. [Through Rate]

42.39

1039

44043.21

... More
[33.14]Supplying, filling, spreading and levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer -in-charge. [Through Rate]

42.39

1039

44043.21

... More
[33.18.3]Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 3. 200 mm dia [Through Rate]

2

259

518

... More
[33.19]Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by `V` notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire and labour charges of air compressor, tools and accessories etc., all as per requirement and direction of Engineer-in-charge. [Through Rate]

16

1030

16480

... More
[33.6.1.2]Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. 1.2. All types of soil 350 mm dia [Through Rate]

25

559

13975

... More
[33.9.3]Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 3. 200 mm nominal size dia [Through Rate]

25

980

24500

... More
[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]

18552.78

78

1447116.84

... More
[4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate]

1425.6

64

91238.4

... More
[4.17]Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). [Through Rate]

606.8

3

1820.4

... More
[4.2]Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. [Through Rate]

4250

3

12750

... More
[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate]

2191.45

46

100806.7

... More
[6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) [Through Rate]

106.05

3476

368629.8

... More
[6.1.3]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 3. 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) [Through Rate]

71.16

3426

243794.16

... More
[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate]

124.83

2442

304834.86

... More
[6.14.1]Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) [Through Rate]

65.52

4374

286584.48

... More
[6.22.1.3]Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 1.3. All works above plinth and up to floor IV level : M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) [Through Rate]

935.96

3149

2947338.04

... More
[6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate]

4309.47

4464

19237474.08

... More
[6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate]

2764.16

4502

12444248.32

... More
[6.26.2]Extra for providing richer mixes up to plinth and at all floor levels. 2. Providing M-35 grade concrete instead of M-25 grade BMC/ RMC. (Note : Cement content considered in M-35 is @ 350 kg/ cum) [Through Rate]

7073.65

119

841764.35

... More
[6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate]

1315.09

156

205154.04

... More
[6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. [Through Rate]

3762.66

282

1061070.12

... More
[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate]

10009.65

208

2082007.2

... More
[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate]

5288.96

296

1565532.16

... More
[6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate]

5421.97

262

1420556.14

... More
[6.30.7]Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases [Through Rate]

256.71

290

74445.9

... More
[6.32.1]Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 1. Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) [Through Rate]

179.55

146

26214.3

... More
[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate]

120427.98

66

7948246.68

... More
[6.39.1]Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate]

20.21

4135

83568.35

... More
[7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]

549.43

4128

2268047.04

... More
[7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate]

1754.94

4488

7876170.72

... More
[7.28.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) [Through Rate]

1114.82

488

544032.16

... More
[7.30]Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. [Through Rate]

1114.81

75

83610.75

... More
[8.26.2.1]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.1. Granite of any colour and shade Area of slab up to 0.50 sqm [Through Rate]

100.55

2750

276512.5

... More
[8.27.2]Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work [Through Rate]

1360.8

230

312984

... More
[8.28]Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. [Through Rate]

41

393

16113

... More
[8.6.2]Providing and fixing cramps of required size and shape in RCC/ CC / Brick masonry backing with cement mortar 1:2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). 2. Stainless steel cramps [Through Rate]

120

418

50160

... More
[8.7.1.2]Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 1.2. Wedge expansion type Fastener with threaded dia 10 mm [Through Rate]

480

21

10080

... More
[9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [Through Rate]

44

147

6468

... More
[9.33]Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm ( plus 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. [Through Rate]

315

504

158760

... More
[9.47.2]Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 2. GI Metal Ceiling Lay in perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. [Through Rate]

302.19

1031

311557.89

... More
[9.57.1]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 1. 75 mm diameter [Through Rate]

520

121

62920

... More
[9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter [Through Rate]

48

200

9600

... More
[9.57.3]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter [Through Rate]

850

269

228650

... More
[9.58.1.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.2. Coupler 110 mm [Through Rate]

60

82

4920

... More
[9.58.1.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.3. Coupler 150 mm [Through Rate]

64

118

7552

... More
[9.58.2.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 2.2. Single push fit Coupler 110 mm [Through Rate]

20

74

1480

... More
[9.58.2.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 2.3. Single push fit Coupler 150 mm [Through Rate]

170

101

17170

... More
[9.58.3.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 3.2. Single tee with door 110x110x110 mm [Through Rate]

20

155

3100

... More
[9.58.3.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 3.3. Single tee with door 150x150x150 mm [Through Rate]

34

210

7140

... More
[9.58.4.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 4.3. Single tee without door 150x150x150 mm [Through Rate]

42

205

8610

... More
[9.58.5.1]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.1. Bend 87.5° 75 mm bend [Through Rate]

56

59

3304

... More
[9.58.5.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5° 110 mm bend [Through Rate]

20

93

1860

... More
[9.58.5.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5° 150 mm bend [Through Rate]

116

129

14964

... More
[9.58.6.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 6.2. Shoe (Plain) 110 mm Shoe [Through Rate]

88

79

6952

... More
[9.58.6.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 6.3. Shoe (Plain) 150 mm Shoe [Through Rate]

32

113

3616

... More
[9.62.1]Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 1. 100 mm diameter [Through Rate]

50

145

7250

... More
[9.62.2]Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 2. 150 mm diameter [Through Rate]

884

162

143208

... More
SITC of Commercial grade 55 inch DISPLAY UNIT having following technical specification 1.Display Size: 55 inches or more 2.Resolution and built in:3840 x 2160 (UHD) ,4K 3.AUDIO: Advanced Audio 4.Built in :Bluetooth Connectivity (optional), built in Wi Fi, 5.Built in Speaker:20W 6.Others:HDMI X 3, DP X 1,USB X1 ,RJ45 X 1 , Digital audio out. 7.Brightness:300 cd/m2 or better 8.Dashboard feature:SNMP support to take control of display to check, Diagnose and Corrections through LAN network, Wake on LAN 9.Operation Temperature:0 °C to 40 °C or better, humidity 80% 10.Warranty: 3 years onsite 11.Mounting:Wall mount and table mount both 12.Display Type:24x7 working compatibility 13.Certificates and Approvals: BIS, ISO 9001, CB/UL

8

56250

450000

... More
Providing and applying 12-15mm ready mix/ ready plaster RP cement based plaster mortar having density 1500-1600 per m cum and compressive strength in 28 days 10-12 MPA on cement concrete/reinforcement concrete/brick work/AAC Block of approved make as per satisfaction of Engineer in Charge.....

15215.41

266

4047299.06

... More
Supply and Erection of 24-port 19` 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19` 1U straight Patch Panel, 24-port,Should have integral cable management Metal shelf,Should accept Shielded as well as Unshielded jacks, Should have rear cable management shelf metallic powder coated.

4

8048

32195.2

... More
Providing and fixing of Woven vinyl carpet floorings series with roll dimensions of 1.8/2mtr meters width and length of 20 meters or Tiles size as per company standard should be approved by architech. 2.50-2.80 mm thickness to laid on hard, levelled, smooth and moisture free sub floor. Woven Vinyl flooring should have traffic classification 33 and weight of 2.7-3.5 kg/m2. Flooring should have caster chair EN-985 tested with color fastness of more than 6. It should be ASTME662 qualified on Smoke density test. Product must be fire rating of the product should be Bfl-S1. Any Joints in flooring rolls should be sealed with cold welding.As per approved shade and colour as per the satisfaction of the Architect.MAKE: LG/ Woderfloor.

1802.42

3062

5519010.04

... More
Supplying, installation, testing and commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.

1

69750

69750

... More
Supplying, installation, testing and commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc. as required Supplying, installation, testing and commissioning of intelligent addressable programmable sounder complete as required.

160

113

18080

... More
Supplying, installation, testing and commissioning of fault isolator complete with base as required.

40

2419

96760

... More
Supplying, installation, testing and commissioning of addressable beam detector with short circuit isolator (inbuilt or separate complete with emitter and receiver including connections with remote test features etc. complete as required.

4

59063

236252

... More
Supplying, installation, testing and commissioning of fire fighter telephone handset complete as required.

2

3094

6188

... More
Supplying, installation, testing and Commissioning of intelligent interface unit BAC net/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required.

1

144000

144000

... More
Supplying, installation, testing and commissioning of fire fighter phone jack complete as required.

26

1181

30706

... More
Supplying, installation, testing and commissioning of 6 inches dia, 2 watts, 70/ 100 volts ceiling speaker complete as required.

80

1294

103520

... More
Supplying and laying of 2x 1.5 sqmm fire survival armored cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armoring and LSZH outer sheath complete as required.

13400

276

3698400

... More
CONTROL PANELS Fabrication, supply, Installation testing and commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter- connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump pressurization pump and diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required: INCOMING 630A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-630 A) with selector switch and CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 800Amps OUTGOING (Note: All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) MAIN FIRE PUMP 250 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation. selector switch for local/remote, auto/manual/OFF operation. JOCKEY PUMP 125 A, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL Control for diesel engine comprising- Automatic/Manual selector switch and 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0- 30 V DC volt meter, and 0-20 A DC. Ammeter All standard relays and accessories for automatic operation of diesel engine. SYSTEM CONTROLLER Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification.

1

253125

253125

... More
S.I.T.C. of auto glow exist sings and indication signs of size 12” x 4” and attack fire, DP indication at every exit point, fire point, fire extinguisher compete in all respect.

90

1350

121500

... More
Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the nonvolatile memory (EPROM), power supply unit (230 t 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for BMS system with open protocol BAC net/ Modbus over IP complete as per specifications: Ten Loop Panel

2

376875

753750

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding. excavation and providing cement concrete blocks as supports anticorrosive treatment with coaltar/asphalt tape as per IS 10221. Refilling the trench etc. of following sizes complete as required. 200 mm dia (Wall Thickness = 6.3 mm)

20

4483

89660

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding. excavation and providing cement concrete blocks as supports anticorrosive treatment with coaltar/asphalt tape as per IS 10221. Refilling the trench etc. of following sizes complete as required. 150 mm dia

550

3139

1726450

... More
Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: Stainless Steel ( G- 304)

9

1406

12654

... More
Providing and fixing flow switch in following sizes M.S. pipe including connection etc. as required. 100mm dia

4

4331

17324

... More
Providing and fixing flow switch in following sizes M.S. pipe including connection etc. as required. 150mm dia

5

5456

27280

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 4 way-150 mm dia MS Pipe

3

8775

26325

... More
Providing, fixing, testing and commissioning of 15mm dia quartzite bulb type sprinklers of rating 68 degree centigrade with required accessories. Horizontal side wall sprinkler

307

422

129554

... More
(A) Supplying. installation, testing and commissioning of electric driven pressurization pump suitable for automatic operation and consisting of following, complete in all respects, as required: ( Jockey Pump) (B) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS: 1520. (C) Suitable HP squirrell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS:325. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required (E) Suitable cement concrete foundation duly plastered and with anti-vibration pads. 180 LPM at 88 m Head.

2

95625

191250

... More
(A) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520 (C) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325 (D) M.S. fabricated Common base plate, coupling, coupling guard foundation bolts etc. as required (E) Suitable cement concrete foundation duly plastered with anti-vibration pads. (Note: The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/ farthest point.) 2280 LPM at 70 m Head

2

299250

598500

... More
(A) Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) (B) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (C) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts electric starting equipment, diesel tank exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (D) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required (E) Suitable cement concrete foundation duly plastered and with anti-vibration pads. (Note: The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/ farthest point.) 2280 LPM at 70 M Head

1

545625

545625

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 50mm dia

2

2756

5512

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 80mm dia

2

3431

6862

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 150mm dia

3

5456

16368

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 200 mm dia

3

10744

32232

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 250mm dia

1

15244

15244

... More
Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required: 50mm dia

2

3206

6412

... More
Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required: 80mm dia

6

5006

30036

... More
Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required: 100mm dia

20

5456

109120

... More
Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required: 150mm dia

9

12319

110871

... More
Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required: 200mm dia

3

21319

63957

... More
Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required: 250mm dia

1

30994

30994

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/I$ 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 25mm dia

1350

535

722250

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 32mm dia

135

647

87345

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 40mm dia

106

782

82892

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 50mm dia

100

984

98400

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 65mm dia

110

1209

132990

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 80mm dia

160

1434

229440

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 100mm dia

425

1659

705075

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 150mm dia

335

2784

932640

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 250 mm dia(wall thickness 6.3 mm)

20

5259

105180

... More
S/E of 70/72W LED Street light luminaire with powder coated pressure die-cast aluminium housing,high efficiency LED, toughened glass with IP66 protection, , working hour minimum 50000 hours, operation on single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. [3Q]

9

4106

36954

... More
Supply and erection of LED Downlighter 12 watt, operation on single phase AC supply complete in all respect up to the entire satisfaction of Engineer- in - charge of the work including making necessary connections etc. [3Q]

176

1024

180224

... More
S/E of stay set suitable for 9/11 mtr long PCC pole made out of 7/8 SWG GI wire with U type MS rod 5/8`dia duly threaded by means of angle iron of size 50mmx6mmx6mm, 30 cm long and 6 ft. long MS rod5/8` dia, 5` buried in the ground after fixing with cross channel of size 75mmx40mmx60cm. The stay wire will be binded on the top of the pole with the help of suitable size of double U type MS clamps and tied with nuts and bolts. the stay wire shall be insulated in the middle pointwith the help of insulator and complete with one coat of red oxide with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. ii) With Disc insulator (for H.T. Pole) [3Q]

4

1800

7200

... More
SUPPLY and ERECTION of -11 meter long PCC Pole 152 mm x 203 mm at top and 152 mm x 368 mm at bottom with working load of 360 Kg. burried 2.20 m in ground. [3Q]

2

5569

11138

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required,(i) Stainless Steel (Grade 304) [3Q]

28

3938

110264

... More
Supply and Erection of hose box double door(750*600*250 mm) suitable for 2 No. hose pipe 15 meter, 1 No. short branch pipe complete in all respect. [3Q]

9

5456

49104

... More
Providing and Fixing of ABC Type 6 kg (Stored Pressure) Fire Extinguisher filled with Mono Ammonium Phosphate Powder MAP 50% Confirming to ‘IS 4308’, Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose and Nozzle and Epoxy Polyester Powder Coated Mild Steel body, Fire Extinguishers As per ‘IS 15683 : 2018’ ISI Marked. [3Q]

39

3488

136032

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bond with GI wire, rivets etc. conforming to IS 636 (Type-A) as required: Stainless Steel (Grade-304). [3Q]

56

3594

201264

... More
Supply and erection of LED light 2` x 2` 36 Watt, operation on single phase AC supply upto 35000 working hour complete in all respect up to the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. [3Q]

97

2869

278293

... More
Supply and erection of 25 Ltr. commercial RO plus UV, Fully automatic with auto cut off RO plus UV Water Purification system 25 ltr/ hr capacity complete with all labour and petty material required i/c making necessary connections upto entire staisfaction of Engineer-in-Charge of the work [3Q]

8

22275

178200

... More
S/E OF WATER COOLER OF SS BODY WITH 150 LTR. STORAGE and COOLING CAPACITY WITH ALL PETTY MATERIAL AS PER BRAND LIST. [3Q]

8

45000

360000

... More
PROVIDING AND FIXING HAND SHOWER (HEALTH FAUCET) WITH 8MM DIA 1 METER LONG FLEXIBLE TUBE AND WALL HOOK CAT NO. (ALD-CHR-573) make Jaquar complete in all respect (Updated 05.03.2024)

36

1413

50868

... More
PROVIDING AND FIXING 12 INCH TOWEL RAIL (GRAB BAR) CAT NO. (AQN- CHR-7711B) make Jaquar complete in all respect (Updated 05.03.2024)

56

1639

91784

... More
PROVIDING AND FIXING TOWEL RING CAT NO. (AQN- CHR-7721) make Jaquar complete in all respect (Updated 05.03.2024)

36

1336

48096

... More
PROVIDING AND FIXING Soap Dish CAT NO. (AQN-CHR-7731) make Jaquar complete in all respect (Updated 05.03.2024)

36

1500

54000

... More
Supply and Erection of 2 Core 1.5 Sq mm Speaker Cable Make Havells/Polycab/Finolex. [3Q]

500

129

64500

... More
Supply and Erection of 10 mtr HDMI Cable Make Kramer / Manhattan/ AMX 3Q]

1

10114

10114

... More
S/E LED 18 W downlighter/square /round surface/recess mounting white colour working hour minimum 35000 hours operations on single phase AC supply complete in all respect upto the entire satisfaction of engineer in charge of the work including making necessary connection etc.(3QN)

188

1519

285572

... More
Supply and erection of Fire Extinguisher ISI marked CO2 type of 4.5 Kg capacity as per IS :7285 duly erected/ hags on wall with hooks i/c the cost of hook, screws etc. with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer in Charge of the work. /[3Q]

39

5119

199641

... More
Supply, Installation, Testing and Commissioning of Outdoor Junction box PVC.

183

2138

391254

... More
Supplying. Installation, testing and commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required.

310

2025

627750

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. (a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 (b) 20 mm nominal internal dia gun metal globe valve and nozzle. (c) Drum and brackets for fixing the equipment`s on wall. (d) Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket. (DSR2022/18.17.1) 30 m size

19

6535

124165

... More
Providing and fixing of pressure switch in M.S. pipe line including connection etc. as required.

5

1463

7315

... More
Providing and fixing Auditorium chair complete in all respect (Warranty period of Five years include AMC of the product). The specifications are as under:- Providing and arranging auditorium chairs that are aesthetically pleasing, cozy, and well-designed. The back will be composed of 15mm plywood with PU foam, and the seat will be made of 12mm thick hot- pressed plywood with HR polyurethane foam upholstered in fire-resistant fabric tapestry. There must be a seat sliding mechanism on the chair. The armrest needs to have a cup holder and be composed of PP. Every metal component needs to have a minimum 40 micron black powder coating applied to it. The grouting plate, which measures 170 mm by 85 mm by 3.5 mm in thickness, must be welded. The dimensions of the seat are 470±10 mm (W) x 440±10 mm (D), the back is 820±10 mm (H) from the seat x 540±10 mm (W), and the total height is 1040±10 mm. The chair must be Grennguard (Ul), indoor air quality (IAQ), Confederation of Indian Industry (CII) certified. (3Q).

1515

11000

16665000

... More
Providing and fixing Fully Insulated Non Metallic Wooden Fire door at all levels. Wooden fire door should carry 120 minutes Insulation properties. Main Door frame shall be Single rebate profile of section 120 x 70 mm made out of Hard wood - Red merandi / Ivory Coast (2nd class ) as per requirement with factory made groove of suitable size so as to accommodate Fire and smoke seal of size 20x4mm . The frame must be primed with Fire retardant primer. Wooden shutter must be of minimum 52mm of thickness finished with commercial ply on both faces. The commercial ply must be finished with Fire retardant primer. The Commercial ply may also be pasted with Laminate in desired shade (payable in extra item). The composite thickness of the core insulation will be 44mm consists of Calcium Silicate boards of approved make and treated wool Insulation material. The shutter should be provided with heat activated intumescent fire seal strip of size 20mm x 4 mm mounted in the suitable grooves all three sides except bottom provided on Exposed OR concealed wooden lipping . Vision panels wherever required should be of 120 minutes fire rated clear non wired type. All hardware’s, Fasteners and FR Glass shall be payable in Extra item. Door shutter provided with commercial ply on both faces with 1mm Thick Regular SF grade Factory pasted Laminate on both faces and Main frame made out of hardwood frame. Frame primed with Fire retardant primer. FIXTURES OF DOORS: (A) Supply and fixing of SS Ball Bearing Hinges of size 100 x 75 x 3mm complete with SS Screws of BB1953 Becker Fire Solutions / DORMA 3090F / GEZE Make (4 No’s per panel), (B) Supply and fixing of anchor fasteners of HILTI/ FISHER/ Equivalent of M10X120mm length. (C) Supply and fixing of door closers of BLC-604 Becker Fire Solutions/ TS-89 DORMA / GEZE TS 2000 Series Make. (Except shaft door). (D) Supply and fixing of Stainless Tower Bolt 300mm Long for Double leaf door of height up to 2100mm of Becker Fire Solutions. / Dorset Make with necessary screws as required. (E) Supply and fixing of Stainless Tower Bolt 600mm Long for Double leaf door of height up to 2400mm of Becker Fire Solutions. / Dorset / EQ make with necessary screws as required. (F) Supply and Filling the gap between wall and Door frame by using silicone sealant and Wool insulation on both side of the door(3Q)

54.72

23625

1292760

... More
SITC of 22U equipment rack with provision for housing all control equipment with front and rear door, blower for cooling and proper locking arrangements and as per the specifications, complete in all reapect upto the entire satisfaction of engineer in charge of the work. Complete in all respect as per Directions of Engineer-in-Charge.

2

13169

26338

... More
SITC of LED `COB` WASH LIGHT for CYCLORAMA: using 60 Nos.x 4w RGBW Hi-Power 3-in-1 LEDs : IP-65 rated : Power AC 240V / 50Hz 240W : Lamp Life: )50000 hours : Beam Angle: 60°: 0-100% electronic linear Dimmer, 1-10 times/sec strobe: DMX-512 signal, 6 DMX Channels : Al.die-cast housing : s/w Power and DMX data link cables: 4-leaf Barndoors and suitable clamp. Complete in all respect as per Directions of Engineer-in-Charge.

6

50236

301416

... More
Gigabit Managed Network switch with PoE. Complete in all respect as per Directions of Engineer-in-Charge.

1

30148

30148

... More
SITC of 16 Port Gigabit switch. Complete in all respect as per Directions of Engineer-in-Charge.

7

25749

180243

... More
Providing and Fixing of installation control valve with turbine type automatic Alarm Gong to be connected with control valve, drain and test valve as per manufacturer`s specifications complete. (i) 150mm dia.

1

37297

37297

... More
Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Stainless Steel seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. (i) 25MM

1

1516

1516

... More
Supply, installation, testing and commissioning of plug in type analogue addressable Multicriteria Detector (Heat cum Smoke) with soft addressing feature including the cost of base plate with twin LED for 360° view complete as per specification.

4

1817

7268

... More
Providing and Fixing of Control Module to control the other systems such as elevators, automatic doors etc

11

6589

72479

... More
Providing and Fixing of Monitor Module to activate the fire fighting system, Exhaust fans, etc

34

6248

212432

... More
`Proving and fixing ISI Marked Dual Type Non-return valves flanged end class PN-1.6 as per IS:5312/2004 in pipe lines including jointing and cost of Nut Bolt , rubber insertion etc complete (i) 150mm dia(Dual Type NRV)

3

12584

37752

... More
Supplying, Installation, Testing and Commissioning of cast iron flanged Y type strainer with stainless steel mesh in PN-1.6 including cost of Nut Bolt , rubber insertion complete in all respects. (i) 250 mm dia

1

38791

38791

... More
SITC of Industrial type pressure gauges with gun metal / brass valves complete in all respect

9

725

6525

... More
Providing and fixing in position CP jali of Heavy quality, 100mm dia of standard make approved by Engineer-in-charge complete in all respect (3Q).

118

147

17346

... More
Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect )110mm dia Plain Bend.

55

124

6820

... More
Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe (110mm dia) class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect ) Door tee. (3Q)

68

200

13600

... More
Providing, laying and jointing specials with required rubber seal and solvent of PVC/SWR pipe (110mm dia) class (type B) and ISI marked i/c filling joint solvent mixture complete in all respect ) Plain tee. (3Q)

47

158

7426

... More
Providing and fixing 50mm wide colour contrast `EDGE STRIPS` self addhesive on treads of stair cases to help people with visual diabilities and elederly even in dim light condition complete in all respect to the entire satisfaction of Engineer-in-charge (NS) (Latest 3 Nos Quotations)

140

84

11760

... More
Providing and fixing `L` shaped `Grab Bar` 600mm long and 30mm 40mm thick dianmeter of 18-gauge made up of `stainless steel` of International Standard in the toilets to make them `Unisex Toilet` for visually impaired visitors as per design / specification and guidelines complete in all respect to the entire satisfaction of Engineer-in-charge (NS) (Latest 3 nos quotations)

36

7459

268524

... More
Providing and Fixing of Emergency Assistance Alarm System for toilets (Wireless) having 3-way splitter unit i.e. Pull Cord for differently abled persons/ Senior Citizens, reset system and Over Door Alarm having compact design, High Visibility and as per harmonized guidelines laid by the Government. (NS) (Latest 3 nos quotaions)

1

25425

25425

... More
SITC of ERD unit having 30 KV Capacity for 13 passenge lift having 3Phase in 3Phase Out ,With inbuilt isolation transformer ,Micro controller based IGBT technology ,Advanced technology: DSP based controller for power and monitoring ,True online dual conversion design , 30nos.*12V/42AH for 30Kva,Heavy duty angle iron racks plus UNINVYN fire retardant copper battery interlinks,Wireless RF based voice guided display unit with transmitter, signal booster and receiver Complete in all respect.

4

447750

1791000

... More
Supply, Installation, Testing and Commissioning of Analogue Addressable type Smoke Detector with Visible bi-color LEDs for 360 deg having Rotary, decimal addressing system in the range of 01-159, complete with standard base, as required, complying to EN54 and LPCB/UL.

156

3116

486096

... More
Supply, Installation, Testing and Commissioning of Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54 having Rotary Decade Switches for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/UL.

40

4647

185880

... More
P/F Soap Dispenser with Glass Bottle (CAN-1135N) Jaquar make or equivalent.

36

1350

48600

... More
P/F Toilet Roll Holder with Stainless Steel Flap (CAN-1153S) Jaquar make or equivalent.

36

1181

42516

... More
P/F Wall Mixer Non-Telephonic Shower Arrangement with Connecting Legs and Wall Flanges (SOL-6219) Jaquar make or equivalent.

18

5113

92034

... More
Providing and fixing SWR UPVC SWR P-trap (DS) 110x110mm dia complete in all respect.

180

274

49320

... More
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical confirming to IS:1520 (C) Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325. (D) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered and with anti-vibration pads. 900 LPM at 35 m Head

2

81563

163126

... More
Supply and fixing Air vessel made of 250mm dia x 1200mm high with air release valve top and flanged connection to riser, drain arrangement with 25mm dia gunmetal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

4

13204

52816

... More
Supply, Installing, Testing and commissioning of Hard Disk 10TB for NAS storage WD Ultra Star.

12

28114

337368

... More
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with Class O closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant/Client in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system.(Make : Rajco,Mandev,Totaline,Hariom) (I) 34.9 mm OD (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

220

2160

475200

... More
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with Class O closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant/Client in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system.(Make : Rajco,Mandev,Totaline,Hariom) (I) 28.6 mm OD (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation...

180

1586

285480

... More
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with Class O closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant/Client in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system.(Make : Rajco,Mandev,Totaline,Hariom) ..(I) 22.2 mm OD (ins(Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation.

400

979

391600

... More
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with Class O closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant/Client in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system.(Make : Rajco,Mandev,Totaline,Hariom) (I) 19.1 mm OD (Hard drawn) with tube thickness 1.2 mm with 13 mm thick insulation..

295

821

242195

... More
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with Class O closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant/Client in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system.(Make : Rajco,Mandev,Totaline,Hariom) (I) 15.9 mm OD (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation..

220

686

150920

... More
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with Class O closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant/Client in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system.(Make : Rajco,Mandev,Totaline,Hariom). (I) 9.5 mm OD ((Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation..

180

343

61740

... More
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF /VRV system etc. complete in all respects duly insulated with Class `O`closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes and layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system. ..41.3 mm OD (insulation = 19mm)

295

2572

758740

... More
SITC of Master Control Unit inbuilt A/v alarm Control Panel along with sounder cum strobe of 24VDC operated red colour MS housing , 2 NO/NC potential free relay contact for Main Fire Alarm. Modbus for BMS Integration. Gas discharge led indicator, battery led indicator, system status Led indicator, AC power ON Led indicator...

40

29152

1166080

... More
Supply of Wall Fan 16` Sweep ( 400mm)oscilating pipe light duty complete with built-in regulater, blade, jali etc. .Make:- as per HPHC approved Brand List WITHOUT GST..

2

2059

4118

... More
Supply, Installation, Testing and Commissioning of 5 MP BULLET Camera 30 mtr IR with below mentioned minimum features: Type of Camera: Bullet Image Sensor: 1/2.8 ` progressive Scan CMOS Resolution and frame rate: 5 MP @ 20fps OR Better Minimum Illumination: 0.05 Lux or better, F 1.6 or better Video Compression (Minimum): H.264, H.265, or better Wide Dynamic Range: Real/True WDR (120 db or more) Storage: Including 256 GB SD card- class 10 Audio Recording: Including internal and External Mic IR: 30 mtr. Or higher Network Protocol: TCP/IP, UDP, IPV4, IPV6, HTTPS, SNMP, DHCP Enclosure: IP67, IK10 Standards: BIS, UL/CE/FCC Power: PoE Reset Button: Required Lens Type: Lens Type: 2.8- 8mm or better motorized lens Lens: F 1.6 or better Signal-to-Noise Ratio: 50 dB or more System Capability: Should be ONVIF Profile G, S and T Note : Quoted Model should be listed on ONVIF website and CCTV OEM should not be blacklisted by ONVIF. Operating Condition: 0 °C to 55°C, humidity 80% (max) VMS Support: Camera shall support open-source VMS Additional Features: Defog, BLC,HLC Video Analytics: Motion Detection, Tampering Video Encryption: AES/TLS/SRTP NDAA Compliant: Yes..

146

17820

2601720

... More
Supply, Installation, Testing and Commissioning of 5 MP DOME Camera 30 mtr IR with below mentioned minimum features: Type of Camera: Dome Image Sensor: 1/2.8 ` progressive Scan CMOS Resolution and frame rate: 5 MP @20fps OR Better Minimum Illumination: 0.05 Lux or better, F 1.6 or better Video Compression (Minimum): H.264, H.265, or better Wide Dynamic Range: Real/True WDR (120 db or more) Storage: Including 256 GB SD card- class 10 Audio Recording: Including Mic IR: 30 mtr. Or higher Network Protocol: TCP/IP, UDP, IPV4, IPV6, HTTPS, SNMP, DHCP Enclosure: IP67, IK10 Standards: BIS, UL/CE/FCC Power: PoE Reset Button: Required Lens Type: Lens Type: 2.8- 8 mm motorised lens or better or equivalent Lens: F 1.6 or better Signal-to-Noise Ratio: 50 dB or more System Capability: Should be ONVIF Profile G, S and T Note : Quoted Model should be listed on ONVIF website and CCTV OEM should not be blacklisted by ONVIF. Operating Condition: 0 °C to 55°C, humidity 80% (max) VMS Support: Camera shall support open-source VMS Additional Features: Defog, BLC Video Analytics: Motion Detection, Tampering Video Encryption: AES/TLS/SRTP NDAA Compliant: Yes..

37

16038

593406

... More
Supplying of 10 Watt, 0.5 Metre, LED Bollard Light fittings alongwith its all accessories like potted electronic LED driver made out of Die Cast base and opal acrylic diffuser having IP-65 protection and mechanical impact resistance rating of lk)=07. The fixture should have a minimum system efficacy of )100 lumen/Watt.The fixture driver should have an operating voltage range of 140-270 Volt, surge protection of )=10KV, PF))0.90, THD (20%. The fixture shall be designed for a system life of 50,000 hours. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.(as per HPHC Brand List) (Make-Phillips / Havells / Wipro / Bajaj)

26

6800

176800

... More
Supply, Installation, Testing and Commissioning of 1.5 TR, 5 star, Inverter type, Wall mount `Split Air-conditioning unit `, single phase consisting of condensing indoor unit, outdoor unit of copper coil, MS stand, copper wound digital stabilizer 4 KVA , 160V -270V , copper refrigerant piping and cabling between indoor and outdoor unit upto 3 meter etc. complete in all respect i/c making repair of wall, floor and roof in original shape caused by making holes and chases etc.

4

49511

198044

... More
Supply, installation, testing and commissioning of NVR, 64 Channel , with Incoming and out going bandwidth of 320 Mbps each , 8 SATA port , with minimum 40 TB (4 X 10 TB) storage with below mentioned minimum features: supporting channel :64 channels Bandwidth :320 Mbps (Incoming)/320 Mbps (Outgoing) Recording Resolution: UP to 8 MP Video Output:1 or 2 HDMI Ports USB interface:1xUSB 3.0, 2XUSB 2.0 Raid :RAID 0/1/5/6/10 Minimum Storage :Minimum 8 SATA ports (Support up to 10TB Each SATA Port) Alerts: Generate alerts for camera or equipment malfunction and replacement, HDD failures, HDD tampering, etc. Auto start/ Resume :should be capable of auto start/Resume operations post power fluctuation/ failure Access Management: Feature to limit access to storage data with access management Connectivity Interface:2 Nos. x 10/100/1000 Base-T Lan Port Backup and other Interface:1 e-SATA Port Protocols: NTP, SNMP Operating Condition:0°C to 55°C, humidity 80% (max) Alarms I/O: Minimum - 1 Alarm input ports and 1 Alarm Output Ports System Capability: Should be ONVIF Profile G, S and T Note: Quoted Model should be listed on ONVIF website and NVR OEM should not be blacklisted by ONVIF. Certifications :BIS Certified, UL/CE/FCC Additional feature :Auto sync - SD card to NVR, Auto resume ,VMS: Must have pre-loaded VMS, ONVIF complaint.

3

196020

588060

... More
Supplying of 200 W LED Flood light luminaire, housing made up of die cast aluminium/ aluminium alloy, complete with driver, LEDs with Optic Lenses, toughened glass cover and mounting bracket. The fixture should have a minimum system efficacy of 120 lumen/Watt, ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK )=07. The fixture driver should have an operating voltage range of 140-270 V, surge protection of )=10KV, PF )0.9, THD (10%. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. (Make-Phillips / Havells / Wipro / Bajaj).

5

11593

57965

... More
Supply, installation, testing and commissioning of 12 W COB downlighter Recess mounted complete with pressure die-cast aluminium housing, LEDs and electronic driver with THD (10% Output Short Circuit Protection, Surge Voltage Protection. Minimum system efficacy of 100 lumen/Watt Total Lumen shoud be 1200lumen, Operating voltage range 140 V-270 V and beam angle 60°. The fixture shall be designed for a average LED life L70B50 50000 hours. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. ( Make-Phillips / Havells / Wipro / Bajaj).

132

1526

201432

... More
Supply, Installation, Testing and Commissioning of 40 watt decorative LED (Housing LED) to be mounted on decorative pole complete in all respect upto entire saticfation of engineer in Charge. ( CAT no. Twinkle PT - 230- HY).

13

8415

109395

... More
Supply and Erection of 5 mtr. Decorative pole complete in all respect upto entire satisfaction of engineer in Charge. ( Twinkle Luxmax SP-114-502-Z4).

13

17487

227331

... More
Supply and Erectrion of Bracket on Existing Decorative Pole complete in all respect upto entire satisfaction of engineer in Charge. ( Twinkle Luxmax BKT - 46 single).

13

8879

115427

... More
Supply, Installation, Testing and Commissioning of Size/Dimension 9U rack Height 600mm Width x 600 mm Depth, Color RAL 7035 Light Grey Usable Width 482.6mm (19 Inch),Usable Depth 200mm (07.87 in) Overall width 575mm Overall Depth 300 mm ,Overall Height 500mm (19.68 Inch),Height in 9U,Product Part No. RSOD009-001,Usable Height 400 mm (15.75 Inch).

12

11813

141756

... More
Supply and laying of hardener at top surface 5 kg/sqm of trimix M-30 to finish surface complete in all respect.(Rate Derived from HSR B0400) 30.07.2024

4874.99

236

1151716.39

... More
Supply, Installation, Testing and Commissioning of UL/FM Certified Extinguishing agent filled in PESO Approved Filling Station: 2 Kg FK-5-1-12 Clean agent filled in PESO approved stored pressure type seamless steel cylinder as per IS 7285 (life 15years) with automatic type DLP valve assembly PI marked, TPED (Transportable Pressure Equipment Directive) approved, Used Standards for type approvals ISO 17871:2015 in conjunction with EN ISO 10297:2014 EN ISO 14246: 2017-12, Push in connector, End of line adapter, UL listed Pr. Switch, end of line plug, T connector, Safety Burst Disc at 28 Bar and Mounting Bracket. Stored Pressure type fitted with Pressure gauge, UV Resistance, Operating Pressure 15 bar, Hydraulic Pressure Tested to 250 bar, Burst Pressure at 350 bar, Red Powder coated. Certified by National Test House, Dept of Consumer Affairs, Govt. of India. system design as per NFPA 2001 and Installed as per LPS 1666

15

72785

1091775

... More
Supply, Installation, Testing and Commissioning of Master Control Unit inbuilt A/v alarm Control Panel along with sounder cum strobe of 24VDC operated red colour MS housing , 2 NO/NC potential free relay contact for Main Fire Alarm. Modbus for BMS Integration. Gas discharge led indicator, battery led indicator, system status Led indicator, AC power ON Led indicator.

15

29152

437280

... More
Supply, Installation, Testing and Commissioning of UL Certified Linear pneumatic Heat Detection Tube (ID-6mm and OD-8mm) for automatic fire detection and suppression system made by special modified polyimide (PA), colour red RAL300, burst temperature 1310C, inner diameter 6mm, outer diameter 8mm. Pressurized with dry nitrogen at 15 bar pressure with all necessary fittings and supports. Certified by National Test House, Dept of Consumer Affairs, Govt. of India.

600

3581

2148600

... More
Supplying, Installing, Testing and Commissioning of Axial flow fan complete and inclusive of motor, supporting frame, G.I. Welded wiremesh inlet guard and including back draft dampers at outlet etc. as per drawings and specifications.Note :a) All motor shall be EFF-2 and H-Class,b) Fan outlet Velocity shall not exceed 16 m/s.c) Factory fitted Backdraft dampers and all accessories shall be part of the Axial fan d) All the fans would be 2 hrs. Fire rated at 250oC Smoke Air Exhaust:-7540 Cubm/Hr. (3500 CFM) at 40 mm WG, 500 mm dia, 2.2 kw motor Retail smoke exhaust fan (3Q)

2

52988

105976

... More
Supply, Installation, testing and commissioning of Axial flow fans complete with motor, supporting frame, gravity louvres, weldmesh inlet guard etc. with necessary civil work as per drawings and specifications Fresh air:-7540 Cubm/Hr. (3500 CFM) at 40 mm WG, 500 mm dia, 2.2 kw motor Retail smoke exhaust fan (3Q)

2

63000

126000

... More
Lift lobby Pressurization Supply, Installation, testing and commissioning of Axial flow fans complete with motor, supporting frame, gravity louvres, weldmesh inlet guard etc. with necessary civil work as per drawings and specifications. 12920 Cubm/Hr. (7600 cfm)at 40 mm WG, 630 mm dia, 3.7 kw motor (3Q)

4

105975

423900

... More
Supply, installation, testing and commissioning of main panel boards made of 2.0 mm thick steel sheet duly powder coated complete with voltmeter,ammeter, indicating lights, selector switch,incoming/ outgoing isolators, current operated single phase preventor, CTS contactors, A/M Switch for remote controls operation complete as per specifications and drawings and as required.Incomer:1 No. 63 Amps MCCB TP plus NL of 25 KA breaking capacity incoming.1 No. 100 Amps aluminium bus bar duly sleeved as required.1 No. CT operated ammeter with selector switch.1 No. voltmeter with selector switch and control fuse.3 Nos. phase indicating lights with control fuse.Outgoing :4 Nos. 40 Amps MCCB of 15 KA breaking capacity outgoing 4 Nos. DOL Starter for 3.7 KW motor Axial fan 12920 CMH for Lift lobby Pressurization 1 No. 40 Amps of spare.All Starters shall have following accessories,Overload relays,Ammeter with selector switch and CTs,Single phase preventer of MPRD-2 type,ON/OFF indicating lights,ON/OFF push buttons (3Q)

1

96030

96030

... More
Supply, Installation, Testing and Commissioning of Integrated master controllers 6 and 8 channel Digital Voice Evacuation which is expandable by slave controller, capable to supervise all the speaker circuits, with required number of zone control as given below and accessories required to complete the system. Failure of Fire Panel CPU shall not result in failure of DVC operation.DVC shall be with in built with fireman microphone , PA Zone control and Remote Paging mic unit. built-in EVAC and alert voice message by SD card,auto changeover into standby when fault, with extension amplifier connector, AC mains and DC battery operation.6 Zone EVAC Controller, built-in 500W class-D amplifier, built-in EVAC and alert voice message by SD card, with fireman microphone, with AB speaker line low impedance supervision, with amplifier auto changeover into standby when fault, with extension amplifier connector, AC and DC battery operation. (3Q)

1

232470

232470

... More
Supply, Installation, Testing and Commissioning of Integrated master controllers 6 and 8 channel Digital Voice Evacuation which is expandable by slave controller, capable to supervise all the speaker circuits, with required number of zone control as given below and accessories required to complete the system. Failure of Fire Panel CPU shall not result in failure of DVC operation.DVC shall be with in built with fireman microphone , PA Zone control and Remote Paging mic unit. built-in EVAC and alert voice message by SD card,auto changeover into standby when fault, with extension amplifier connector, AC mains and DC battery operation.6 Zone Router, built-in 500W class-D amplifier, with 8 zone speaker outputs and volume control, receive sources and fire alarm message from master controller, with AB speaker line low impedance supervision, with amplifier auto changeover into standby when fault, with extension amplifier connector, AC and DC battery operation. (3Q)

1

193725

193725

... More
Supply, Installation, Testing and Commissioning of Booster Amplifier capable of delivering 240/480/1000 Wattage RMS power output for speakers, built-in fan for temperature control, built in line matching transformer distortion typically ( 3% @1 KHz, S/N) 80 dB complete as required, Inbuilt Line Converter, 70v and 100v output. 240 W (3Q)

3

67158

201474

... More
Supply, Installation, Testing and Commissioning of Booster Amplifier capable of delivering 240/480/1000 Wattage RMS power output for speakers, built-in fan for temperature control, built in line matching transformer distortion typically ( 3% @1 KHz, S/N) 80 dB complete as required, Inbuilt Line Converter, 70v and 100v output.480W (3Q)

1

90405

90405

... More
Supply, Installation, Testing and Commissioning of Remote Paging Unit with annunciator with zone controls and all zone control microphone with accessories as required.12 Zones Control (Remote Paging Microphone, 12 zone capacity with 12 keypad buttons, each system can connection up to 32 remote microphone, DC24V power supply.) (3Q)

1

77490

77490

... More
Supply, Installation, Testing and Commissioning of Remote Paging Unit with annunciator with zone controls and all zone control microphone with accessories as required .Zone Extension Key Pad to RM-EVAC-12Z paging microphone, 12 Zone capacity, up to 11 nos keypad can be connected to EVAC-RM microphone.(3Q)

1

37454

37454

... More
Supply, Installation, Testing and Commissioning of 6` 6W Ceiling Speaker with SPL at rated power/1W 90dB (1m and 1kHz). Frequency response of 125Hz – 16kHz (-10 dB with reference to 1kHz). The speaker should have tapping`s at 6W/3W/1.5W.` (3Q)

78

1369

106782

... More
Supply, Installation, Testing and Commissioning of 15W Wall mount with 96dB . Frequency response of 110 Hz ~13K Hz. The speaker shoud have tappings at 15W/7.5W/3.75W (3Q)

28

3875

108500

... More
Supply, Installation, testing and commissioning of cubical type dust and vermin proof H.T. Metering panel free for standing floor mounting suitable for 11 KV 3 Phase supply made out of14 gauge MS sheet with channel from base frame painted with staving synthetic light gray enameled paint suitable for operation on 11 KV 3 Phase four wire 50 cycle systems effectively earthed system and consisting of the followings:- i) 3nos 11 KV C.T of required capacity with burden class 0.5 S of approved make by HVPN. ii) ONE No PT 11KV/110 volts 3 phase oil cooled 10 VA class 0.5 of make as approved make by HVPNL .iii) 2 NOS cable holes for incoming and outgoing 11KV cable. iv)Wiring and terminal block v) THE panel will be complete with all internal wiring, inter connection of VT and HT, compound filling of cable and boxes, HT cable connections etc. complete in all respect as approved by UHBVN/DHBVN authorities including the cost of security for H.T. Meter, testing fee of CTs, PT another equipment`s as required by UHBVN/DHBVN authorities.

1

85200

85200

... More
Supply, Installation, Testing and Commissioning of 10 KVA sine wave online UPS 3 Phase input and Single phase output with 16 x 42Ah 12V Exide batteries, minimum 1 hour power backup and VAH 16385 Voltage Range -320V to 460V AC 3 Phase, Output 230V AC, frequency 50Hz. Warranty as per OEM standards complete in all respect with allied cables and necessary connection upto the entire satisfaction of Engineer In Charge.

5

253125

1265625

... More
Providing and fixing suspended false ceiling with glass fiber reinforced acoustic gypsum baord of Size 1200X2500X12.5mm with round random perforation G8/15/20 with 9.9% perforation and NRC upto 0.55 .Installation includes providing and fixing GI perimeter channels of size 0.55 mm. Thk. having one flange of 20 mm and another flange of 30 mm and web of 27 mm along the perimeter of the ceiling, screw fixed to brick wall/ partition with help of nylon sleeves and screws, at 610 mm centers. The suspended GI intermediate channels of size 45 mm,0.9mm thk with two flanges of 15 mm each from the soffit at 900 mm centers with ceiling angle of width 25mm x 10mm x 0.55mm thk fixed to soffit with GI cleat and steel expansion fasteners. Ceiling section of 0.55 mm thk having web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are fixed to the intermediate channels with help of connecting clips and in direction perpendicular to the intermediate channel with centers of 333 mm perforated gypboard is then screw fixed to ceiling section with 25 mm dry wall screws at 300 mm centers to G.I. framing in perfect level. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally the boards are to be joined and finished so as to have a flush look with uniflot. Product comes with Cleaneo Technology - Air purification and Air quality.Active reduction of air polluants thanks to Cleaneo Technology effectively reduces concentrations of VOC’s like alcohol, aldehydes, ketons and esters as well as unpleasant odours from e.g. food or cigarette smoke Air purification properties tested according to CEN standards and VDI guidelines by Fraunhof Insistute for Building Physics The false ceiling surfaces shall be prepared to the satisfaction of the Architect, and shall be applied with two coats of primer and Paint to the satisfaction of Architects. (Make Armstong, Gridsquare, Anakon, Anuton)

1532

2231

3418504.8

... More
Providing and fixing heavy Duty S.S Handle bolt (8` long) with nuts and screws etc complete (Grade 304)

238

102

24276

... More
Providing and fixing heavy Duty S.S tower bolt (18` long) with nuts and screws etc complete (Grade 304)

119

413

49147

... More
Providing and fixing Heavy Duty. S.S tower bolt (6` long) with nuts and screws etc complete (Grade 304)

119

106

12614

... More
Providing and fixing Heavy Duty S.S Sliding bolt (300mm x16 mm dia.) with nuts and screws etc complete (Grade 304)

27

209

5643

... More
Providing and fixing Heavy Duty S.S Sliding bolt (200mm x 16 mm dia) with nuts and screws etc complete (Grade 304)

65

173

11245

... More
Providing and fixing of 150 mm floor stainless steel door stoppers, godrej make with rubber cushion screws etc to suit shutter thickness complete.

119

143

17017

... More
Providing and fixing tiled false ceiling of specified materials of size 600 x 600 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm center to center to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-chargeProviding and fixing Knauf Danoline Perforated glass fiber reinforced Gypsum tile Belegravia MICRO with Square perforation of size 3×3 mm with c/c 8.33 mm spacing and size of 12.5mm* 600*600 mm. The reverse of the board incorporates an acoustic fleece which provides sound absorption performance( NRC value 0.60) . Front surface is White acrylic paint, RAL 9003, gloss 5. Product comes with Cleaned Technology -Active reduction of air pollutants due to Cleaned Technology, effectively reduces concentrations of VOC’s like alcohol, aldehydes, ketones and esters as well as unpleasant odors from e.g. food or cigarette smoke Air purification properties tested according to CEN standards and VDI guidelines by Fraunhofer Institute for Building Physics The false ceiling surfaces shall be prepared to the satisfaction of the Architect (Make Armstong, Gridsquare, Anakon, Anuton)

2299.2

2897

6660782.4

... More
Supply and Installation of Fire Resistance Door Size 2000X2400 mm, 46 mm thick Tata steel door shutter of 120 minute fire rated confirming to BS-476, Part 20-22 and lS:3614 part-II, Prototype certified from Govt. approved Lab. GQMC / CBRI Roorkee. fabricated with 2 nos of 0.8 mm thick galvanized steel sheet sandwiching fire insulation materials in between suitable for 120 minute. Door frame are manufactured with 1.2 mm thick galvanized Tata steel sheet pressed to form single rebate profile of size 100X58mm and fixing with dash fastener of approved size including Ball bearing butt hinge of size 1OOX75X3mm with screws in SSS 304 grade, Door Closer, 5mm thick Saint Gobin Fire Rated Vision Panel (Size 200X300 mm), Triple Point Panic Bar, Panic Trim, Fasteners etc. The frame and shutter are finished with powder coated approved shade, including all contingent work there to, complete in all respect upto entire satisfaction of Engineer-in-charge. (Make Navair, Ziplex, Becker Fire Solutions)

27

68006

1836162

... More
Supply and Installation of Fire Resistance Door Size 1200X2400 mm, 46 mm thick Tata steel door shutter of 120 minute fire rated confirming to BS-476, Part 20-22 and lS:3614 part-II, Prototype certified from Govt. approved Lab. GQMC / CBRI Roorkee. fabricated with 2 nos of 0.8 mm thick galvanized steel sheet sandwiching fire insulation materials in between suitable for 120 minute. Door frame are manufactured with 1.2 mm thick galvanized Tata steel sheet pressed to form single rebate profile of size 100X58mm and fixing with dash fastener of approved size including Ball bearing butt hinge of size 1OOX75X3mm with screws in SSS 304 grade, Door Closer, 5mm thick Saint Gobin Fire Rated Vision Panel (Size 200X300 mm), Triple Point Panic Bar, Panic Trim, Fasteners etc. The frame and shutter are finished with powder coated approved shade, including all contingent work there to, complete in all respect upto entire satisfaction of Engineer-in-charge.(Make Navair, Ziplex, Backer fire Solutions)

4

35300

141200

... More
Providing and Fixing Channeled Woodworks perforated panels of width 128/192mm, thickness of 15mm and length 2400 mm or as required by the Engineer- in-Charge, made of Moisture Resistant fiber board with minimum 595 Kg/M3 density substrate with a laminated facing as per the approved shade and finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a Helmholtz fluted perforation of 3mm width and 21mm of visible panel each. The edges of the panels shall be tongue- and-grooved to receive special clips for installation. The back of the perforated panel shall have sound absorbing non- woven acoustical fleece having NRC value not less than 0.7. The panels shall be mounted on special aluminum splines using clips.The panels shall be mounted on special splines of GI steel fixed at the spacing of 600mm centre to centre and made of aluminium extruded channel size of 15mmx25mmx20mm with the help of clips required size and shape as per manufacturers specification.The thermal insulation shall be provided with Resin Bonded Rockwool confirming to IS 8183 having density of 48kg/m3 x 50mm, wrapped in virgin polythene bags fixed to the wall. Place the inside clip on the groove end of the panel along the Al keel and then place the tongue end of the next panel. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing inside clips into the next keel till the actual height is achieved. All complete with necessary synth / glass wool and frame work as per manufacturer specification. (GRIDSQUARE/ARMSTRONG/ANUTONE/Anakon)

1577.96

7932

12516410.28

... More
Providing and supplying Acoustical Wall Paneling with square edges made of rockwool tissue substrate 50mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class BS-476, as per part 4, 20, fabric with an option of colors – Ivory, Autumn Orange, Pista Green, Straw Gold, Rustic Green, Burgundy, Rust, Peacock Blue, Ash Grey, Mocha as per the choice of the Architect of size 600X600 mm providing a minimum sound absorption level of 0.80 NRC to be affixed to wall using Wall panel impalers construction adhesives as per the instructions laid down by the manufacturer. INSTALLATION: 4nos. l panel Impalers of shall be fixed to the wall surface using self tapping screws. Silica based construction adhesive to be dabbed on to the projecting elements (spikes) of the impalers. Wall panels shall be pierced through the spikes of the impalers ensuring the line and level of the panels are aintained(.GRIDSQUARE/ARMSTRONG/ANUTONE)

1309.64

8100

10608097.1

... More
Supply and fixing of 50/85 mm continuous line puf roof panel having 0.5mm PPGI sheet outer side and 0.4 mm PPGI sheet inner side of 120gsm, 240MPA on both side,puf infill density 40 plus -2 kg/m3.RAL 9002(trapezoidal outer and inner micro ribbed panel) fix with self teaping screws with bitumen warsher and filling silicon complete all respect. (Make Anakon, Jindal, Everest)

2595.1

2888

7494648.8

... More
Providing and fixing of PPGI Flusing (Make Anakon, jindal, Everest)

146.94

154

22628.76

... More
Supply and erection of GRC screens( jali) 50 mm thick in approved designs and sizes factory manufactureed containing alkali resistant Glass Fiber of make NEG, Japan and fixing by Dry Cladding using SS Cleats, SS Threading rods , Self Tapping Screws and Fischer make pure epoxy chemical fastner (Em Plus with RGM/ GM 8.8 grade rods ) as per design, complete including scaffolding and all other plants and machinery with all type of labour . ( Unicrete , Unistone,Rajesh GRC) with entire satisfaction of Engineer in charge. (MS structure paid seperately)

140.03

3520

492905.6

... More
Supply of Door handle size 32mmx457mm H-type (CTC 308mm) to required colour or shade, with necessary SS screws and Nut etc. complete :- (make:- OZONE, Dorma, Hettics )

20

2485

49700

... More
Supply of Patch Lock to required colour or shade, with necessary SS screws and Nut etc. complete :- (make:- OZONE, Dorma, Hettics)

10

2922

29220

... More
Supply and Installation of Fire Resistance Door Size 1500X2400 mm, 46 mm thick Tata steel door shutter of 120 minute fire rated confirming to BS-476, Part 20-22 and lS:3614 part-II, Prototype certified from Govt. approved Lab. GQMC / CBRI Roorkee. fabricated with 2 nos of 0.8 mm thick galvanized steel sheet sandwiching fire insulation materials in between suitable for 120 minute. Door frame are manufactured with 1.2 mm thick galvanized Tata steel sheet pressed to form single rebate profile of size 100X58mm and fixing with dash fastener of approved size including Ball bearing butt hinge of size 1OOX75X3mm with screws in SSS 304 grade, Door Closer, 5mm thick Saint Gobin Fire Rated Vision Panel (Size 200X300 mm), Triple Point Panic Bar, Panic Trim, Fasteners etc. The frame and shutter are finished with powder coated approved shade, including all contingent work there to, complete in all respect upto entire satisfaction of Engineer-in-charge. (Make Navair, Ziplex Backer Fire Solutions)

2

60307

120614

... More
Providing and Filling Construction and Longitudinal joints (6 mm wide x 65 mm deep) in VDC/PQC M30 by groove cutting machine, providing and filling joints with Polysulphide Pour Grade sealent of approved make in the VDC M-30 complete as per specifications and directions of Engineer-incharge. (Item of dowel bars / tie bars to be paid separately). Derived from HSR

591.35

395

233583.25

... More
Providing and fixing for SWR Pipes (80 mm to 150 mm) specials tees, bends, couplers, single y, cross tee, short bend etc. conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge Plain Y Junctions 110MM (Supreme, Finolex, Prince)

50

415

20750

... More
Providing and fixing for SWR Pipes (80 mm to 150 mm) specials tees, bends, couplers, single y, cross tee, short bend etc. conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge Double Y Junctions 110MMx110mmx110mmx110mm (make Supreme, finolex and Prince)

26

722

18772

... More
Providing and fixing for SWR Pipes (80 mm to 150 mm) specials tees, bends, couplers, single y, cross tee, short bend etc. conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge Plain Y Junctions 160MM (Supreme, Finolex, Prince)

47

925

43475

... More
Providing and fixing for SWR Pipes (80 mm to 150 mm) specials tees, bends, couplers, single y, cross tee, short bend etc. conforming to I.S 4985:2000 . Including the cost of carriage and all fixing labour as per entire staisfication of Engineer incharge Double Y Junctions 160MMx160mmx160mmx160mm (Supreme, Finolex, Prince)

26

1424

37024

... More
VANITY 1300 (W) X 600 (D) X 900 (H) VANITY: STRUCTURE MADE OF 18MM THICK IN HDMR plus PRE-LAMINATED BOARD AND FRONT MADE OF 25MM THICK HDMR plus PRE-LAMINATED BOARD WITH 2MM THICK PVC EDGEBANDED FINISH LAMINATE AS PER DESIGN and SHADE.VANITY SIZE 1300W X 600D X 900mm (H) (Jaquar, Kohlar and Hindware)

16

45479

727664

... More
SITC of 24 Watts Ceiling Loudspeaker, Maximum power 36 W,Sound pressure level at 24 W / 1 W (1 kHz, 1 m) -106 dB / 92 dB (SPL),Sound pressure level at 24 W / 1 W (4 kHz, 1 m) - 107 dB / 93 dB (SPL),Effective frequency range (-10 dB) -60 Hz to 18 kHz,Opening angle at 1 kHz/4 kHz (-6 B)-160° / 60°,Rated voltage -100 V,Rated impedance 417 ohm.

14

11858

166012

... More
SITC of 240 Watts Amplifier ,Inbuilt Bluetooth for audio streaming , Supports audio playback from USB pen drive ,4 microphone/line inputs, plus music source input , Insert feature to use as a pre/power amplifier , Optional 2 tone chime generation for input 1 , Frequency response - 80 Hz to 18 kHz ( plus 1/ 3 dB @ 10 dB ref. rated output , Distortion -(1 % @ rated output power, 1 kHz, Sensitivity - 200 mV to 300 mV, Impedance -22 kohm.

2

36619

73238

... More
SITC of Interactive Display 98 inch Display Size : 98 inch, Display, Resolution : 3840(H) ×2160 (V), Aspect Ratio : 16:9, Display Color : 1.06Billon colors, Brightness : =450 cd/m², Response Time(ms) : 6-8ms, Glass Thickness : 4mm, Touch Surface : Anti - Glare and Anti scratch, Contrast ratio : 1200:1, Dynamic Contrast Ratio : 30000:1 with OPS • i5 Processor • 8GB RAM • 256 GB SSD.

1

845719

845719

... More
SITC of Full HD PTZ Camera supporting 1080p at 60 Frames per Second, minimum 12X Optical Zoom with FoV of 72 degree and minimum 255 presets. Camera should support simultaneous outputs through IP, HDMI, USB 3.0 and 3G-SDI, Audio In and can be controlled via RS232/422 and IP. Panning angle -170° ~ plus 170° , Tilting angle -30° ~ plus 90. Camera should support SRT, PoE and should be compatible with Virtual USB Driver. OEM should be BIS, CE,RoHS and FCC Certified.

4

219375

877500

... More
SITC of Multiviewer with streaming solution for Video Conferencing with 4 x HDMI inputs and 1 x HDMI and 1 x USB 3.0 outputs supporting 18Gbps (600MHz) 4K UHD support, Seamless switching with no loss of sync to display when switching sources in 4x2 matrix mode, supports to store a multi-window arrangement as a preset, EDID management, Supports easy adjustment of window size, position and settings in the PiP windowing mode via the WebGUI and controllable via front panel buttons, WebGUI, Telnet, RS-232. Ability to automatically scales 4K sources to 1080p for USB capture with video timing stabilization to help ensure a reliable and stable USB capture stream, should support capturing 2 channel digital audio from either HDMI (LPCM 2.0) or the 3.5mm analog audio input (selectable via capture software). Compliance with the UAC (USB Audio Class) and UVC (USB Video Class) standards to support most common capture and video streaming.

2

340031

680062

... More
Supply installation testing commissioning of 450mm Gooseneck microphone with a programmable microphone button (Toggle on/ off, PTM, PTT, and permanent on) and a bi-color LED ring for status indication. 450mm length, condenser capsule with cardioid pickup pattern, Frequency response: 50 Hz - 20 kHz, Maximum sound pressure level: 130 dB SPL, Connectivity: XLR 3M. It should have TTL-logic output for camera control feature.

4

63000

252000

... More
SITC of 43 Inch , Screen Resolution - 3840 x 2160, Brightness 400cd/m2, Inbuilt Memory 16 GB, 2GB DDR3 2133Mhz RAM, Android OS Version11, Built in Google Play store, Screen Mirroring for Android and Windows devices, preinstalled APPs: YouTube, Netflix, etc. HDMI x 3, USB x 2, RJ45 x 1, AV IN x 1, SPDIF Out - Yes Optical, Headphone out, Viewing Angle 178/178 degree, Sound Surround Mode - Yes, Speaker output - 2 x 10W, Rated Power Consumption 95W, Standby Power Consumption 0.5W, Power Supply AC 110V – 240V,Capability to run Digital Signage Software of Same OEM, Built in Chrome cast,24x7

5

49180

245900

... More
SITC of Wireless Content Presentation, Collaboration, and Conferencing Solution, Wireless content sharing and collaboration applications ,Optimized for video conferencing using room peripherals, Local video streaming output to large displays, Direct run of 3rd party web applications, Wireless sharing from Miracast™ and AirPlay™, Powerful security features, Switched enabled wired input, Centralized cloud management and control, PORTS -1 Ethernet: On an RJ–45 connector, 2 USB 3.0: On a female USB type–A connector, 1 USB 2.0: On a female USB type–A connector, 2 Pin connector: Video Switching control

2

191813

383626

... More
SITC of 2 Core Power cable 1.5 sqmm.

200

108

21600

... More
SITC of Mic Cable

70

48

3360

... More
SITC of 15 Mtr HDMI cable Connectors at both ends

3

13078

39234

... More
SITC of 20 Mtr HDMI cable Connectors at both ends

2

23018

46036

... More
SITC of 24 port Gigabit switch.

1

51188

51188

... More
SITC of WIFI Access point.

2

48150

96300

... More
SITC of 15U Equipment Rack with provision for housing all control equipment with front and rear door, Blower for cooling and proper locking arrangements

2

17438

34876

... More
SITC of Intel Core i5 PC of higher, 8 GB RAM, 500GB SSD and Window 11, Warranty 1 Year

1

122063

122063

... More
Chairman Unit for Priority button, Optional chime tone facility preceding chairman announcements. Microphone with flexible stem and light ring. Two headphone sockets.Interconnections * 1 x 2.7 m (106.3 in) cable terminated with a 8-pin male connector for loop-through connection to other.* 1 x 8-pin circular female connector for loop-through connection to other delegate or chairman units.* 2 x 3.5 mm (0.14 in) stereo headphone sockets.

2

20053

40106

... More
-SITC of Delegate Unit, Built-in volume control for headphones, Microphone with flexible stem and light ring , Two headphone sockets Interconnections * 1 x 2.7 m (106.3 in) cable terminated with a 8-pin male connector for loop-through connection to other. * 1 x 8-pin circular female connector for loop-through connection to other delegate or chairman units. * 2 x 3.5 mm (0.14 in) stereo headphone sockets.

2

18915

37830

... More
SITC of Control Unit , Controls up to 50 Discussion units , 3-Band equaliser for better sound performance, Audio interfaces for connecting external audio equipments ,Mains voltage - 230VAC,50 Hz (±10%), DC voltage supply to contribution units -24V ± 1V DC,THD at rated output - (1%, Mic input sensitivity - 1 mV ( plus 1/-3dB),sensitivity-100mV ( plus 1/-3dB),Frequency response - 200 Hz to 12 kHz, Input Impedance - 4.7 kohm

1

43594

43594

... More
SITC of Extension cable assembly 10M

3

2964

8892

... More
SITC of Premium-sound cabinet loudspeaker ,Maximum power - 45 W , Rated power - 30 W (30 / 15 / 7.5 / 3.75 W), Sound pressure level at rated / 1 W (1 kHz, 1 m) -105 / 90 dB (SPL), Effective frequency range (-10 dB) - 100 Hz to 18.5 kHz, Opening angle 1 kHz / 4 kHz (-6 dB) - 160° / 81° (horizontal) / 150° / 90° (vertical), Rated input voltage - 15.5/70/100 V, Rated impedance -8 / 163 / 333 ohm

4

19181

76724

... More
SITC of 120 Watts Amplifier ,Inbuilt Bluetooth for audio streaming , Supports audio playback from USB pen drive ,4 microphone/line inputs, plus music source input , Insert feature to use as a pre/power amplifier , Optional 2 tone chime generation for input 1 , Frequency response - 80 Hz to 18 kHz ( plus 1/ 3 dB @ 10 dB ref. rated output , Distortion -(1 % @ rated output power, 1 kHz, Sensitivity - 200 mV to 300 mV, Impedance -22 kohm

1

28772

28772

... More
SITC of 1.5 mtr HDMI cable in existing pipe/ channel connectors at both ends complete in all respect.

8

3139

25112

... More
-SITC of 18U Equipment Rack with provision for housing all control equipment with front and rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work.

1

23541

23541

... More
Supply, Installation, Testing and Commissioning of High Power Three-Way Bi-amp / Tri-amp Switchable Loudspeaker with 1 x 15” LF and Rotatable Horn: Coverage Pattern should be 60° x 40° or better with rotatable waveguide: Should have Frequency Range 39Hz–20kHz orbetter: Should have PEAK Maximum SPL (LF) 133dB - 136dB or better, (MF/HF) 139dB - 142dB or better: Sensitivity (LF) 97dB - 100dB or better: Sensitivity (MF/HF) 108dB - 111dB or better: Should have PEAK Long Term 100hrs Power rating (LF) 2400W - 2600W orbetter: Should have PEAK Long Term 100hrs Power rating (MF/HF) 800W - 1000W orbetter: Impedance 8 Ohms / 10 Ohms: Should support Bi-amp mode and Tri-amp mode switchable : Should have 15 ormore M10 points for suspension: etc.

4

502141

2008566

... More
Supply, Installation, Testing and Commissioning of Flying, dual 15` LF or more subwoofer: Frequency Range 32 Hz – 1 kHz (-10 dB): Frequency Response 38 Hz – 1 kHz ( ± 3 dB): System Sensitivity (dB-SPL, 1W @ 1m)-100 dB: Maximum SPL 132dB - 135dB or more: Long-Term System Power Rating: 1350 W - 1450W: etc

2

433164

866328.76

... More
Supply, Installation, Testing and Commissioning of M10, Eye-Bolt Kit for above Loudspeakers and Subwoofer Unit: etc. A

6

5343

32062.5

... More
Supply, Installation, Testing and Commissioning of High Power TwoWay Loudspeaker with 1 x 15” LF and Rotatable Horn: Coverage Pattern should be 120° x 60° ormore with rotatable waveguide: Frequency Range 35Hz–20kHz orbetter: Should have PEAK Maximum SPL 130dB - 133dB orbetter: Passive Crossover Frequency: 1.4kHz: Sensitivity Should be 96dB - 99dB or better: Should have PEAK Power rating 2400W - 2600W or better: Impedance 8 Ohms: Should support Bi-amp mode and Passive mode switchable: Should have 15 ormore M10 points for suspension: etc

2

310471

620943.76

... More
Supply, Installation, Testing and Commissioning of M10, Eye-Bolt Kit for above Loudspeakers Unit: etc.

2

5343

10687.5

... More
Supply, Installation, Testing and Commissioning of 12` Two-Way Self-Powered Stage Monitor Loudspeaker System: should support Power rating 2000W(pk) ormore: Frequency Range 51Hz – 20kHz orbetter: Max. SPL 132dB or more: Coverage Pattern 90° x 50° or better: Crossover Frequency: 2050Hz: User selectable Optimized presets for Main or Monitor position: 100V - 240V ~ 50/60 Hz Operation: Should support audio connectivity with minium 2 x XLR balanced Combo jacks: 1 x 3.5mm aux input: 2 x XLR-M loop-through: 1 x XLRM mix out: etc

4

203062

812250

... More
-Supply, Installation, Testing and Commissioning of Advanced Feedback Suppression: should support Stereo or Dual Independent Channel Processing: Inputs / Outputs 2In / 2 Out: Max input line level plus 20dBu or more: A/D Conversion 24bit orbetter: THD plus Noise 0.003% or better: Should have Wizard Setup Function: Should have Full LCD Display: 24 or more Programmable Filters per Channel: Live and Fixed Filter Modes: 24 or more LED per Channel Filter Metering: Input Impedance: Balanced 50kO, Unbalanced 25kO: Frequency Response: 20Hz – 20kHz, plus /- 0.5dB orbetter: Crosstalk input to output )80dB ormore: etc.

1

87081

87081.75

... More
-Supply, Installation, Testing and Commissioning of Compact Two - way Loudspeaker with 2 x 8”-10` orbetter LF Driver: PEAK Power rating 1500W - 1800W ormore: Impedance 8 Ohms: Coverage Pattern 120° x 60° or better: Frequency Range 54Hz-20kHz or more, Frequency Response 65Hz-20kHz ormore: Should have Max SPL 120dB - 123dB or above: System Sensitivity 94dB - 97dB or above: Crossover: 2.1kHz: etc.

4

145585

582340.52

... More
Supply, Installation, Testing and Commissioning of Wall Mount U Type Bracket for above Front Fill Loudspeaker: etc

4

11756

47025

... More
-Supply, Installation, Testing and Commissioning of Two Way UltraCompact Wall Mount Loudspeaker for indoor and outdoor uses with 3` - 4` LF Driver, Frequency Range 72Hz–20kHz ormore: Should have Peak Power rating 160Watts - 200Watts or better: Peak Max SPL 109dB or better: Should have 70/100V Transformer taps 15W, 7.5W, 3.7W ormore: 100-120 degree (H) x 100-120 degree (V) orbetter coverage: etc

2

19451

38902.5

... More
Supply, Installation, Testing and Commissioning of Wired Gooseneck Microphone with Desktop base unit for portable podium uses. It should support Cardioid or better polar pattern: built-in on/off switch: Audio frequency bandwidth 70-18000Hz ormore: Signal to Noise 64dB-A orbetter: 500mm (50cm) or more in Length: 9 to 52V Power Interface: etc.

4

40398

161595

... More
-Supply, Installation, Testing and Commissioning of wired Vocal microphone Should be Professional Dynamic Handheld Microphone and On/Off Switch: should support Polar Pattern supercardioid orbetter Audio Frequency bandwidth 70 to 20000Hz ormore: Sensitivity 2.6 mV/Pa or better: Electrical Impedance : 600 Ohms or better: Recommended Load Impedance : 2000 Ohms or more: Connector Type : 3-pin XLR Male (Balanced): Metal Body: etc

4

18810

75240

... More
Supply, Installation, Testing and Commissioning of Wired Dynamic Instrument Microphone with Cardioid orbetter Dynamic Instrument Microphone: Audio frequency bandwidth 50-20000Hz ormore: Sensitivity 2.5 mV/Pa or more: Max. SPL 47dB or more: etc.

6

20947

125685

... More
-Supply, Installation, Testing and Commissioning of Self-Powered Two-Way Studio Monitor with 6.5` - 8.0` LF Driver, INPUT SENSITIVITY : (-10dBV INPUT) 92dB / 1m, Power Configuration: Bi-amplified , HF DRIVER POWER AMP : 56W or better, Class-D , LF DRIVER POWER AMP : 56W or better, Class-D , Frequency Range (-10dB): 41Hz – 24kHz , MAXIMUM CONTINUOUS SPL: 98dB - 101dB, Maximum Peak SPL: 108dB - 111dB or better, MAXIMUM PEAK INPUT LEVEL(-: 10dBV / plus 4dBu) plus 6dBV / plus 20.3dBu: etc.

1

37406

37406.25

... More
-Supply, Installation, Testing and Commissioning of Professional studio grade closed-back headphones for Main FOH Monitoring, should support auto mute technology: Max. Input Power 200mW orbetter: Audio frequency bandwidth 16-28000Hz ormore: Sensitivity 104dB or more: Should comes with a detachable cable: etc.

1

33131

33131.25

... More
Supply, Installation, Testing and Commissioning of Multichannel Digital Network Based Power Amplifier with 1250W - 1300W ormore per channel @ 8 Ohms power output: should have four or more inputs and outputs analog audio channels: Should support 70Vrms and 100Vrms output on all output channels: THD 0.35% orbetter: Should support Cooling Continuously variable speed forced air: Voltage Gain 34dB ormore: Digital audio bus compatibility up to 8 or more audio channel: Should have bridgeable channels even for 100Vrms mode to operate with 200Vrms output: 2digital audio bus RJ 45 port: 1 Ethernet RJ45 port for monitoring and configuration: Should have DSP features Incl. Limiters, Input/output EQ, Delay, Matrix Mixer, Speaker Line Monitoring: Damping Factor )1500 ormore: etc

2

544186

1088372.26

... More
-Supply, Installation, Testing and Commissioning of Multichannel Digital Network Based Power Amplifier with 600W - 650W or more per channel @ 8 Ohms power output: should have four or more inputs and outputs analog audio channels: should support 70Vrms and 100Vrms output on all output channels: THD 0.35% orbetter: Should support Cooling Continuously variable speed forced air: Voltage Gain 34dB ormore: Digital audio bus compatibility up to 8 or more audio channel: Should have bridgeable channels even for 100Vrms mode to operate with 200Vrms output: 2digital audio bus RJ45 port, 1 Ethernet R 45 port for monitoring and configuration: Should have DSP features incl. Limiters , Input/output EQ , Delay ,Matrix Mixer ,Speaker Line Monitoring: Damping Factor )1000 or more: etc.

1

411618

411618.38

... More
Supply, Installation, Testing and Commissioning of Dual channel Digital Power Amplifier with per channel power output of 2100W - 2500W or better @ 4 Ohms / 6 Ohms : Sensitivity shoul be 1.4V, Should have bridge mode power output 6000W - 6800W or better at 4 Ohms / 6 Ohms , Signal to Noise Ratio should be 103dB - 106dB or above, Total Harmonic Distortion should be (0.5%, Damping Factor 20 Hz to 1kHz should be 500 or above, Frequency Response (at 1W, 20 Hz to 20 kHz) plus 0 dB, -1 dB, Crosstalk should be )70 dB or more, Input Impedance 20kO balanced, 10kO unbalanced: etc

1

256500

256500

... More
Supply, Installation, Testing and Commissioning of dual channel power amplifier with 120W - 150W ormore power output @ 8Ohms, 70V/100V: Input Sensitivity: 1.4Vrms for 8-ohms: Input Impedance 20K ohms orbetter: 2xRJ45connector for external controls: etc.

1

84196

84196.13

... More
SITC of Mic Stand

10

2227

22275

... More
Supply installation testing commissioning of 55` 4KUHD resolution LED Display with Android 11, 400 nits brightness, Cortex A55 1.3Ghz processor, Mali G31 MP2, Open GLES3.2, 2 GB DDR RAM, 16 GB Memory, Wifi Type support both 2.4 and 5G Standard, Dolby Audio, Built in Wifi and Cromecast, HDMI CEC, HDMI ARC, Built-in Bluetooth, Hotel mode, Meeting Mode,20W built in speakers, HDMI 2.0 X 2, AV X 1, USB X 2, RJ45 X 1, SPDIF Out x 1,24/7 operational

2

90305

180610

... More
Stand for Confidence monitors.

2

12937

25875

... More
upply, Installation, Testing and Commissioning of Floor BOX with Power/LAN/XLR/HDMI Connectivity and space for AVOIP encoders

5

36562

182812.5

... More
-Supply, Installation, Testing and Commissioning of HDMI recorder with Pass Through. 2TB storage included. With dual slots for HDD. Option of recording to USB-C disks. Support for h.265, h.264.

1

450000

450000

... More
Supply, Installation, Testing and Commissioning of FHD 1080p/60fps,1/2.8``, CMOS, Effective Pixel: 2.07 Megapixels,30x Optical Zoom,8X Digital Zoom,camera should have a standard Video Output and should support HDMI/DVI and 3G-SDI Ports so that Camera can be integrated with standard End Points. Apart from that , It should have native USB 3.0 support along with HDMI/DVI support so that it can also be connected with Software based VC Solution.should have 60.7 Degree or better field of view,should have at least 250 Position Presets,supplied with IR remote control as an included accessory,f4.42mm ~ 132.6mm, F1.8 ~ F2.8,0.5 Lux @ (F2.0, AGC ON),should have at least 250 Position Presets, Digital Noise Reduction,YUY2, H.264 / MJPEG Compression,Horizontal Rotation ±170°,Vertical Rotation -30° ~ 90°,Number of Preset 255,USB 3.0 Type-A, HDMI, 3G-SDI, Rj45, RS232, Line In/Out,VISCA/ Pelco-D/ Pelco-P,CE, ROHS and FCC.

1

337500

337500

... More
-Supply, Installation, Testing and Commissioning of Keyboard and Joystick Control, VISCA protocol campatible keyboard and camera controler, Multifold communication mode - RS485, RS422, RS232, 10M internet(select to order), USB(select to order), Control the rotation of speed dome camera and swinging angle of joystick with nonpolar variable speed control to embody speed dome camera’s rotating speed real-time, Transmission range - All input and output communication port use anti-radar design, powerful anti-jamming performance, the standard transmitting distance is 1200 meters, Key numbersMaximum sub-control keyboard:16 qty, Password - Keyboard operation password on/off/lock function, LCD display for user interface, Protocol - Pelco-D, Pelco-P, VISCA, Communication Range - RS485, RS422: 1200m, RS232: 10m, Cascade connection number - cascade 16 sub-control at most, controller ID:0- 15, Joystick feature of 3D(control: up, down, left, right, zoom), power consumption of 6W.

1

135000

135000

... More
Supply, Installation, Testing and Commissioning of AVOIP Network switch with 24 # 1G Base-T Copper PoE plus Ports, 02 # 1G Base-T Copper Ports, 04 # 1 Base-X Fiber SFP, RAM: 2 GB, Dedicated Quad-Core Cortex-A57 ARMv8 1.8Ghz CPU (64-bit), Packet buffer memory: 16 Mb, Flash: 256 MB, 300W PoE Budget, Switching fabric: 60 Gbps Line-Rate (non blocking fabric).

1

194906

194906.25

... More
-Supply, Installation, Testing and Commissioning of 18Gbps 10-feet HDMI Cable

6

1206

7239.36

... More
Supply, Installation, Testing and Commissioning of 18Gbps 6-feet HDMI Cable

18

649

11698.02

... More
Supply, Installation, Testing and Commissioning of 2.5 Sqmm speaker cable

1050

129

136437

... More
Supply, Installation, Testing and Commissioning of 2 core shielded balanced microphone cable.

300

59

17820

... More
Supply, Installation, Testing and Commissioning of 3 core 1.5 Sqmm power cable

3050

110

336262.5

... More
Supply, Installation, Testing and Commissioning of 6` Hight speed USB A-B 3.0 Cables

2

464

928.12

... More
SITC of 8 core snake cable

100

366

36675

... More
Supply, Installation, Testing and Commissioning of 6` USB C Cable with Thunderbolt and 65W charging support

4

742

2970

... More
Supply, Installation, Testing and Commissioning of Advanced Feedback Suppression: should support Stereo or Dual Independent Channel Processing: Inputs / Outputs 2In / 2 Out: Max input line level plus 20dBu or more: A/D Conversion 24bit orbetter: THD plus Noise 0.003% or better: Should have Wizard Setup Function: Should have Full LCD Display: 24 or more Programmable Filters per Channel: Live and Fixed Filter Modes: 24 or more LED per Channel Filter Metering: Input Impedance: Balanced 50kO, Unbalanced 25kO: Frequency Response: 20Hz – 20kHz, plus /- 0.5dB orbetter: Crosstalk input to output )80dB ormore: etc

1

87081

87081.75

... More
Supply, Installation, Testing and Commissioning of Wired Gooseneck Microphone with Desktop base unit for portable podium uses. It should support Cardioid or better polar pattern: built-in on/off switch: Audio frequency bandwidth 70-18000Hz ormore: Signal to Noise 64dB-A orbetter: 500mm (50cm) or more in Length: 9 to 52V Power Interface: etc...

4

40398

161595

... More
Supply, Installation, Testing and Commissioning of Wired Dynamic Instrument Microphone with Cardioid orbetter Dynamic Instrument Microphone: Audio frequency bandwidth 50-20000Hz ormore: Sensitivity 2.5 mV/Pa or more: Max. SPL 47dB or more: etc...

6

20947

125685

... More
SITC of MAIN CURTAIN made out of Fire Retardant velvet curtain cloth with horizontal sliding arrangement complete with fixing curved rails, brackets, sliding arrangement and motorised operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP motor (Crompton) 2nos. air breaker contactors (LandT / SIEMENS), 2nos. micro switches for auto stop, 3 nos push buttons for fcrward, reverse and stop pcsiticns. The curtain should be· draped to half area when in closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering, with Main Frill. Size:9m x24 including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge

1

365625

365625

... More
SITC of CENTER CURTAIN made out of Fire Retardant velvet curtain cloth with horizontal sliding arrangement complete with fixing curved rails, brackets, sliding arrangement and motorised operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP motor (Crompton) 2nos. air breaker contactors (LandT / SIEMENS), 2nos. micro switches for auto stop, 3 nos push buttons for fcrward, reverse and stop pcsiticns. The curtain should be· draped to half area when in closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering, with Main Frill.including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge. Size:9 m x24 m,

1

36562

36562.5

... More
SITC of REAR CURTAIN made out oftreated black colour crepe/galaze / cloth cotton clotr. with horizontal sliding arrangement complete with fixing curved rails, brackets, sliding arrangement and motorised operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP motor (Crompton) 2nos. air breaker contactors (LandT/SIEMENS), 2nos. micro switches for auto stop, 3 nos push buttons for forward, reverse and stop positions. The curtain should be draped to half area when in closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge. Size:-9 X 24 MTR

1

348750

348750

... More
MAIN VALANCE: SITC of High quality Velvet fabric fire retardant treated as per approved colour and make with a gathering of 100% stitched Oas per site condition, curtain provided with eyelets at every 200/250mm for uniform fixing on 25MM GI PIPE (For Main Valance) including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge. Size: 24Mtr x 1.8Mtr.

1

42750

42750

... More
Supply, installation, testing and commissioning of Wall mounted type indoor unit with cordless remote controller. Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete including cordless remote with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer .Make: Toshiba/Mitsubishi Heavy/O General 2.5 TR hiwall

1

71275

71275

... More
Supply, installation, testing and commissioning of Wall mounted type indoor unit with cordless remote controller. Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete including cordless remote with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer. Make: Toshiba/Mitsubishi Heavy/O General 2.0 TR hiwall

11

69368

763048

... More
Supply, installation, testing and commissioning of Wall mounted type indoor unit with cordless remote controller. Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete including cordless remote with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer. Make: Toshiba/Mitsubishi Heavy/O General 1.5 TR hiwall

8

67462

539696

... More
Supply, fixing and commissioning of refrigerant joint / Branch distibutors between Indoors with nitrile rubber insulation, supporting etc.complete as required. Make: Toshiba/Mitsubishi Heavy/O General

60

5288

317280

... More
Y Joints Supply, fixing and commissioning of refrigerant joint / Branch distibutors between Outdoors with nitrile rubber insulation, supporting etc. complete as required. Make: Toshiba/Mitsubishi Heavy/O General

14

7728

108192

... More
Supply installation Testing and Commissioning of Touch Type centralised controller suitable for Controlling to connect all indoor units as complete as required. Make: Toshiba/Mitsubishi Heavy/O General

1

97627

97627

... More
Drain Piping Supply Installation Testing and Commissioning of rigid UPVC piping with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation etc. complete as required.32 mm dia

420

124

52080

... More
Drain Piping Supply Installation Testing and Commissioning of rigid UPVC piping with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation etc. complete as required. 25 mm dia

350

107

37450

... More
Supply, installation and testing of acoustic lining of ducts with glass wool of 24 Kg/sqcm, the glasswool shall be covered with RP tissue paper and fixed with roofing nut and bolt complete as per specification and complete as per requirement.. Thermal conductivity of the insulation material shall not exceed 0.047 W/moK at an average temperature of 20oC. 25 mm thick acoustic lining Make: UP Twiga/ Ownes Cornin

768

956

734208

... More
Supply installation and fixing of fire retardant non porous double layer flexible connection between each AHU as complete as required. (canvas connection)

15

2700

40500

... More
Grilles / Diffuser Supplying and fixing of powder coated extruded aluminum Supply and Return Air Diffusers with aluminum volume control dampers as per specifications

210

7650

1606500

... More
Grilles / Diffuser Supplying and fixing of powder coated extruded aluminum Supply Air Grills with aluminum volume control dampers as per specifications

120

7650

918000

... More
Supplying and fixing of acoustic lining of duct with Open Cell Nitrile Rubber density 140-180 Kg/m³. Applied by Adhesive, conforming to standard specification. 10 mm thick open cell nitrile rubber

75

506

37950

... More
Supply and charging of Refrigerant gas R-410 for top up as complete as required.

1

354375

354375

... More
-FRILLS Providing and fixing average frills made out of double gathering glazed cotton cloth to be installed above the stage on 25mm dia GI pipe including cost ,conveyance, loading, unloading, labor ,T and P, sundries, scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge. Size:-24 m x 1.5 m,

6

31500

189000

... More
-SIDE WINGS: SITC of Fixed Wing Structure designed as per site condition for a height approx 5.5Mtr x 1Mtr made up of MS Square tube of 25mm or higher size rested on pilotable trolley on a track for the rotation of the wing. Adjustable floor locking screw jacks with rubber grips including cost ,conveyance, loading, unloading, labor ,T and P, sundries, scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge. 9 MTR X 2 MTR

8

47250

378000

... More
-MOTORISED LIGHTING BAR-Supply, installation, testing and commissioning of motorized lighting bar operated with 1 HP 3 phase ( kirloskar I ABBI Siemensl Cromptonl Havells ) motor, Aluminium Ole cast heavy duty gear box` 2 nos. air breaker switch ( LandT siemens) for up and down, 2 nos. micro switch for auto stop, 48 mm dia GI pipe. Pile Winding drum plates of not less than 5mm thickness and suitable dia. to wind 4mm rope for a lift of more than 5 mtr including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge

5

281250

1406250

... More
SITC of MS suspension grid - Providing and fixing MS angle rafters above stage area of stage at 1200x600mm centres with 2 x 40x40x5mm thick MS angle runners and 25x12x12mm thick studs as MS spacers fixed @ 600mm c/c sandwiched between the MS angle runners so as to maintain 12mm gap between MS Angles. The Grid so formed to be suspended from bottom of the roof structure by means of 35 x 5mm thick MS flat suspenders / fixed to the wall / fixed to Proscenium with MS cleats and dash fasteners at 1200mm centre to the Grid including painting. 9 mtr x 23mtr (APPROX) including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge.

240

2643

634500

... More
SIDE LADDER: SITC of STAGE SIDE LADDER : M.S. Pipe Ladders to be provided on sides of the Stage to be fixed on the existing GI pipe or top grid. Made of 50mm x 25mm MS pipe of following 2400*600 including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge

8

9562

76500

... More
SITC of 200WLED PROFILE: Power Supply: AC 100V - 240V, 50-60HZ Source- COB LED,Wattage - 200W, CCT – 3200K / 5600K , CRI - =90 , Beam angle - 19°/26°/36° (Optional), R9 Value 90 plus , Tel. Lighting Consistency Index 97 plus , Pan/ tilt - Manual, Controls - DMX512, Auto run, Master/Slave DMX channels - 1/2CH (Single color), 2/5CH (2in1) : (OPTIONAL ) Dimmer/strobe - 0~100% linearly adjustable/ 1-25 times/sec, Operating Voltage - 90-260V AC, IP Rating - IP20, Operating temperature - 30°C~40°C Finish - Black, Certification: CE including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge

12

61875

742500

... More
SITC of 200W LED FRESNEL : Power Supply: AC 100V - 240V, 50- 60HZ ,Light Source- COB LED, Wattage - 200W,CCT – 3200K / 5600K , CRI - =90, Beam angle - Manual 19°-50° gives a very soft edged beam as well as spreading a great deal of light outside the beam, Pan/ tilt - Manual Controls - DMX512,mater and slave, auto running, sound mode, DMX channels - 1/2CH (Single color),2/5CH (2in1),3/7CH(3in1,4/8 CH(4in1),Color system - Single WW or CW(150W/200W/300W(2in1/4in1)180W(3IN1), Optional, Dimmer/strobe - 0~100% linearly adjustable Operating Voltage - 90-260V AC,IP Rating - IP20 Operating temperature - 30°C~50°C ,Finish - Black Weight - 8.5 Kg,Certification: CE including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge

14

45000

630000

... More
-SITC of 200W LED PC: Power Supply: AC 100V - 240V, 50-60HZ ,Light Source- COB LED , Wattage - 200W, CCT – 3200K / 5600K , CRI - =90 , Beam angle - Manual 15°-35°,Pan/ tilt - Manual,Controls - DMX512,mater and slave, auto running, sound mode,DMX channels - 1/2CH(Single color),2/5CH (2in1),3/7CH(3in1,4/8 CH(4in1) Color system - Single WW or CW (150W/200W/300W) 200W/300W(2in1/4in1)180W(3IN1), Optional Dimmer/strobe - 0~100% linearly adjustable Operating Voltage - 90-260V AC,IP Rating - IP20 Operating temperature - 30°C~50°C,Finish - Black Weight - 8.5 Kg, Certification: CE including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge

8

36000

288000

... More
SITC of WW/CW LED PAR : 150W LED , CCT: TW-3200K/TC-5600K, Ra) 93,voltage : ac-100-240v, 50/60Hz, Max Power 143, Power Connection : Power in and out, DMX XLR : DMX SPLITTER IN/OUT.IP 65 including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- incharge

48

24750

1188000

... More
SITC of MOVING HEAD : Power voltage : AC100-240V , 50/60Hz,Power consumption : 250W,Color temprature : 8500k,Beam Angle : 0 °-3.8°(by aperture},Pan/Tilt : 540°/250°,DMX channel mode : 16 channels,Color Wheel : 14 colors plus white with rainbow effect,Gobo wheel : 1 fixed gobo wheel with 17 gobos plus open,Prism : 8/16/24 facet prism rotating in both directions,Focus : Motorized focus,Frost : 0-100%,Display : LCD display Power Socket : Powercon in including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge

6

106875

641250

... More
SITC of LED BATTEN FOR CURTAIN: Body Material Aluminum alloy structure,Product size 1000mm × 59mm × 116mm, Voltage AC100-240V 50/60Hz Input Power 200W, Lamp Type 18pcs x 10W LEDs Average Life Span 50,000h,Color System 18pcs RGBW 4 in 1 ,Color Temperature 2700K~8000K, Control Channel 8/72/76 control channel modes, Control Mode Standard DMX512, Master/Slave control mode, Sound Active, Auto Run Menu Display LED display, DMX Signal Connection 3-pin XLR In/Out, Beam Angle 25°, 40°(Optional) Working Temperature -20-40?, including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge

18

39375

708750

... More
SITC of LED FLOOD LIGHT:LIGHT SOURCE: 70W -100W , Integrated design - means the case never needs to be opened Long lifetime - no bulb replacements plus 70% light output maintenance to 30,000 hours Slimline - main body is 40mm thick. High efficiency - around 85 lumens/watt (4,300lm) More robust .TYPE: MSSP- LED 100W etc complete as required. including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- incharge

6

16312

97875

... More
SITC of DMX SPLITTER: DMX Splitter with one DMX input and 8 buffered outputs and 3 pin / 5 pin XLR connectors.including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge

4

24750

99000

... More
SITC of LIGHTING CONSOLE: Lighting Console with Internal Flash Drive, similar in functionality to a hard disk but faster and more rugged. Provides enough storage for:- The entire Fixture Library of more than 3,000 files, New Locate Fixture button, Fixture Selects (selecting the top row of faders), 2048 Channels, 240 Intelligent Fixtures,240 Dimmer Control Channels, Theatrical Plotting and Playback functions, Shape Generator for instant creation of patterns and effects, 15 Playback Masters controlling 450 memories, chases or cue lists, MIDI and Bass, Mid, Treble sound to light triggers, Colour VGA output fitted as standard, Front panel now reverse printed PolyCarbonate Laminate using technology from the Diamond 4, this is incredibly hard wearing and looks excellent, Each console individually has an electronic serial , Supplied with PC applications: Avolites Visualiser, Pearl Simulation program and Cache Builder.including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge

1

337500

337500

... More
SITC of DMX LOOP POINT WIRING WITH ALL REQUIRED CONNECTORS FROM SPLITTER TO ALL LIGHTING FIXTURES. including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- incharge

114

3937

448875

... More
SITC of foot power point etc as required. including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge

10

5062

50625

... More
SITC of Suspender cum clamps designed made out of MS material 150mm x 150mm x 5mm MS Base plate Threaded rod, Black powder coated finish All the materials under gone through 7 tank process with various chemical treatment to keep them rust free Suitable to hold various type grid and other rigging systems.including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge

114

618

70537.5

... More
SITC of Light Fixture dual safety Chain made up of GI wire rope Bundled and twisted together Having load bearing capacity above 200 Kgs .including cost ,conveyance, loading,unloading, labour ,T and P,sundries,scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge.

228

393

89775

... More
Providing and fixing of staggered 2nd layers/Mr Ply 12mm thick MR ply of approved make like century, Duron, Green ply, Merino or equivalent fixed to natural wood frame work of approved size fixed at 300 mm c/c both ways The nature wood framework to be supported cleat pads and held in position by 35x35x5 mm angle cleats of 75mm length at 1200 mm centers. The wooden framework to be filled with 25mm thick thermal bonded polyester wadding micron fiber of 1000 gm/sqm (Make: Sunshine india/ Nowofill / Vibrant or equivalent) held in position with 18mm 24 SWG chicken mesh fixed on the bottom of the wooden framework with necessary screws and washers. The cleats to be given two or more coats of zinc chromate primer. The cleat to be prewelded to the and screwed to the wooden framework with necessary screws.The work shall be executed as per drawings ,specifications and instructions of engineer in charge

240

3937

945000

... More
Supply and fixing Engineered Wood flooring:-The blonde hues found in this 3-strip ash floor from the Nordic Naturals Collection range from amber honey to vanilla cream. To create this lively effect, lighter surface wood has been mixed with darker core wood.Collection-Nordic Naturals CollectionSurface treatment-Matt lacquerConstruction-3-layer parquetProduct measurements-200 x 2423 x 15 mm Engineered Wood flooring

240

6750

1620000

... More
Supply, Installation, testing and commissioning of Light Point Wiring from Patch Panel to be Provided near stage to various stage light fixtures with 2.5 Sq.mm 3 Core PVC Insulated and PVC Sheathed Cable including Cable Tray of suitable size for laying these wires on the tray including 15-20 amps metallic clad sockets with box at top etc complete as required. including cost ,conveyance, loading, unloading, labour, T and P, sundries, scaffolding required for work etc, complete as per specification and direction of the Engineer- in-charge.

114

5062

577125

... More
Supply, erection, testing and commissioning of 13 passengers(B plus G plus 2 floors) Electrical Traction Elevator Room less , Gearless with Speed of 1.0 mtr/Second serving 4 Stops and 4 Opening with SS Vandal finish, hand rail, Mirror and Antiskid PVC Flooring to be erected in accordance with the following Technical Specification and as per latest IS Specification. i) Type and capacity: Passenger Elevator App. 884 Kg. 13 person ii) Speed mps : 1.0 mtr per second iii) Travelling (max) in mtrs : Approx. 16 mtrs iv) Serving: (B plus G plus 2) 4 stops, 4 opening- Two-panel center opening Door panels with full-glass) v) Power Supply: 415 V, 3 phase, 50 HZ A C supply. vi) Control: High Performance simplex full collective integrated serial communication control system. vii) Operation: Automatic viii) Motor: Permanent Magnet Synchronous Electric Traction Gearless Motor to be hoisted on guide rail within the elevator hoist way ix) Location of Motor: Motor to be hoisted above the rail within the elevator hoist way. x) Type of Drive: A. C. Variable Voltage Variable frequency with 16 Bit Microprocessor xi) Car inside area : 1600 mm Wide x 1400 mm Deep (2.24 Sq. meter xii) Car Enclosure : S.S Scratch Resistant Cabin, Granite flooring on heavy duty M.S. Platform, Decorative False Ceiling With CFL/LED Lighting, Blower/Rotor motor xiii) False Ceiling : Stainless steel false ceiling in hair line finish xiv) Car Panel : stainless steel (scratch free) Hair line finish xv) Flooring : B,G ,1,2 xvi) Clear Opening of door : 900 mm wide x 2000 mm Height xvii) Door Operation : Automatic DC/AC with adjustable Door Opening and closing timings with center opening sliding door xviii) Car Door: Center opening automatic door Two-panel center opening Door panels with full-glass. Landing door : Center opening automatic door Other Features: i) Battery operated intercom, emergency alarm and emergency light with maintenance free rechargeable battery. ii) Adjustable guide shoes. (Ensures good ride comfort) iii) Digital direction and position indicator in Car and at all landings. iv) Integral full height car opening panel with luminous combined with direction arrows, overload warning indicator and services cabinet v) Hands free press and speak intercom with EPABX for three way communication. vi) a) Automatic rescue device with batteries etc. to rescue the Passenger in case of emergency the device will bring the elevators to the nearest floor and open the door automatically in Case of power / phase failure / low voltage. b) Manual Rescue lever` vii) Full height infrared safety curtain (Highly sensitive safety device for safe entrance and exit of the Passenger into the Car and automatic floor announcer. viii) Diffused lighting in car. ix) Cross flow fans=2 Nos. x) Looking mirror in side of lift car. xi) Face plate Finish: stainless steel in hair line. xii) Face plate: Rectangular. xiii) A three feet high railing shall be provided on car top xiv) The motor shall be high starting torque and low starting current and shall be arranged for self-lubrication. xv) Proper weight screen shall be provided at the hoist way. xvi) Fire retardant compound coated traveling cable shall be used. xvi) 2 Phase Device Fire Man Drive and Fireman switch at ground floor xvii) Micro Movements L.E.D. based Buttons. xviii) Load Weighing device with overload bypass feature. (Audio Visual over load indicator in the car) xix) Steel items such as Door Frames Sill Angles, Fascia Plates, Spring Buffers. xx) Braille fixtures, Lift announcement system, Pit ladder, Hand rail, Pressure sensing device and Additional Car Gate Lock. xxi) Three Side Hand Rails in Stainless Steel Finish xxii) System Capable of withstanding plus 10% to –10% Variation in Supply Voltage Fluctuations. (C.V.T should be provided for Protection of lift against Single phase, Low voltage and over voltage) xxiii) Car Platform constructed out of Cold Rolled Grain Oriented Formed Sheets of Steel xxiv) Fire Rated Landing Doors for a Period of One Hour Only. xxv) The whole machinery shall be mounted on appropriate anti vibration supports to minimize voice and vibration. xxvi) A handrail not less than 0.60mtr long and 1.0 mtr. Above floor level shall be fixed adjacent to the control panel. xxvii) The time of automatically closing door shall be minimum 5 seconds and the closing speed shall not exceed 0.25mtr./ Seconds xxviii) Over speed governor (Electro-mechanical device that prevents free fall in case the lift is travelling at speed more than 10% of the rated speed in downward direction. xxix) All other required features relates the operation of lift by the Handicaps and Blind person and others as per instruction of lift inspector and HBC 2017.

4

2285512

9142048

... More
Supply, Installation, Testing and Commissioning of 12 x 8 Networked Digital Signal Processor With AEC: Should have 12 or more floating AEC in group of 4 or more Channels: DSP with 12 inputs and 8 outputs or more: 12 Control Inputs and 6 Logic Outputs for GPIO Integration: 48V phantom power on all analog inputs: THD: (0.01% 20Hz to 20KHz: Crosstalk: (-75dB or better: Open architecture software configurable: Separate logic processing power: 2 digital audio bus RJ45 Port: 1 Ethernet port for Monitoring and configuration: Capable to handle plus 5V unloaded logic output voltage: Should have speech sense engine: Capable to control 3rd party devices with TCP IP and RS232: Should have 1nos of RS 232 port for integration with control System: Should have Bi-Directional Locate Functionality: Should have 48 or more digital audio Channel Bus: Should have monitoring LED for COM, STAT, ERR and PWR etc.

3

287320

861960

... More
Supply, Installation, Testing and Commissioning of Input Expansion Unit with 8 - 10 Analog audio output: should be capable to route 256 or more audio Channels a CATX cable, Should have DIP Switches for easy configuration for audio channel routing: Height should not more than 1RU: Should supplied by same OEM of above requested chassis based DSP Unit, it will help to avoid any compatibility issue(s) during the time of installation and/or post installation etc.

1

85589

85589

... More
Supply, Installation, Testing and Commissioning of Network Enable Wall mount Keypad Controller with 8 -10 Buttons: Should have PoE (Power Over Ethernet) port: Should have 8 - 10 Programmable Buttons (Multicolored): Capable to trigger any DSP logic: Multicolored 2 Programmable 64x128 Pixel LCDs: Sleep Function: Security: Remote Lock/Unlock and Local Unlock via PIN Entry: Should have knob and capable to control 8 zones separate: Should be from same OEM of supplied DSP Unit(s) to avoid any compatibility issue(s) etc.

3

46261

138783

... More
Supply, Installation, Testing and Commissioning of bidirectional USB module for DSP connection to PC/Mac for soft conferencing.

3

69647

208941

... More
Supply, Installation, Testing and Commissioning of Multiformat HDBT 4K Transmitter should support up to 4in x 1out audio and video switching, routed to the HDMI and HDBT output simultaneously, 3x HDMI input Type A Female Connector, 1x VGA Input, 1x Analog Stereo Inputs , 1x HDMI Outputs ,1x HD Base: supports digital video, audio, bidirectional control , USB2.0 extension and power , HDCP Support Yes: HDCP 1.4 and 2.2, Key Management System for Fast Switching: EDID Management A preferred EDID can be selected for each input or any display EDID can be mirrored to any input independently.

3

141818

425454

... More
Supply, Installation, Testing and Commissioning of 8x8 Matrix Switcher, it should support Minimum 8 HDMI input and 8 HDMI output with Video Input Port : 8 x HDMI, Video Output Port : 8 x HDMI: Should support computer and video resolutions up to 4K/60 4:4:4 orbetter: Should support HDMI 2.0 with a data rates up to 18 Gbps ormore: Should support Front panel, IR, RS232 and Web based GUI control modes: Should support audio input format PCM 2-Channel, PCM Multi-Channel, Dolby Digital, Dolby Digital Plus, Dolby Atmos, Dolby True HD, DTS, DTS HD MA etc.

1

362075

362075

... More
Supply, Installation, Testing and Commissioning of 4K60 Twisted Pair Transmitter , Shall have 4K60 4:4:4 transmitter which supports traditional HD Base T Outputs, and HDMI as an inputs: Shall have onboard USB 2.0 available on the HDBT allows for easy distribution of USB signals between the transmitter and receiver. A USB device, such as conferencing soundbar, can be mounted at the display and connected to a receiver. A laptop can then connect to the transmitter at the table, with USB and video distributed over category cable. It should support long distance transport of Ultra high resolution video, embedded audio, bidirectional RS-232 and IR and USB 2.0 over a single category cable. 4K60 4:4:4 and HDCP 2.2 Support over HD Base T with Display Stream Compression (DSC)– Visually lossless compression and future-proof support, Twisted Pair Cable Type Shielded Cat6, Cat6A and Cat7 / Shielded Cat6A and Cat7, Twisted Pair Cable Length Up to 70m - 100m or more, HD Base T Layer Throughput (Max) 10.2 Gbps, Shall have 1xHDMI , 1x HDBT Output , Shall serial port , Shall have IR TX and RX ports , Input Signal Type HDMI, HDCP DVI , Data Rate (Max) :18 Gbp ,Pixel Clock (Max) Up to 600 MHz, Regulatory Compliance CE, FCC, NRTL, RoHS, WEEE etc.

8

69647

557176

... More
Supply, Installation, Testing and Commissioning of of 4K60 Twisted Pair Receiver, Should support traditional HD Base T as an input, and HDMI as an outputs to connect the display unit: Should have USB 2.0 Pass-through. It should support long distance transport of Ultra high resolution video, embedded audio, bidirectional RS-232 and IR and USB 2.0 over a single category cable. 4K60 4:4:4 and HDCP 2.2 Support over HD Base T with Display Stream Compression (DSC)– Visually lossless compression and future-proof support, Power over HD Base T – Can be powered from HD Base T inputs which means there is no need for an additional power source at the table ,Twisted Pair Cable Type Shielded Cat6, Cat6A and Cat7 / Shielded Cat6A and Cat7, Twisted Pair Cable Length Up to 70m - 100m or more, HD Base T Layer Throughput (Max) 10.2 Gbps, Shall have 1x HDBT, 1 x HDMI Output , Shall serial port , Shall have IR TX and RX ports , Input Signal Type HDMI, HDCP DVI , Data Rate (Max) :18 Gbp ,Pixel Clock (Max) Up to 600 MHz, Regulatory Compliance CE, FCC, NRTL, RoHS, WEEE etc.

11

69647

766117

... More
Supply, Installation, Testing and Commissioning of Integrated Controller, Dual Network Interface card, Should support IPv6 , Shall Supports IEEE Standard for Port-based Network Access Control with the ability to grant or deny network access to devices wishing to attach to a LAN based on credentials tied to the device rather than to a user, Should have High Performance Architecture, Flexible Programming Platform Java, Should have ability to manage secure port TLS and SSH communications with a remote device or server, Enhanced Diagnostics On Serial and IR Ports , Hardware / Software should be Built for 24/7/365 Operation, Should have Ultra-Fast 1600 MIPS processor , 512 MB Onboard RAM , 1 M Non-Volatile Memory, 8 GB SDHC FLASH Memory ,1 RU Rack Space ,10/100 LAN Interface ,4 Digital I/O Ports , 1 RS-232/422/485 Port , 3 RS-232-Only Ports , 4 IR/Serial Output Ports , 4 Relay Ports Shall be supplied with OEM recommended power supply , Regulatory Compliance :RoHS, WEEE etc.

3

147033

441099

... More
Supply, Installation, Testing and Commissioning of External Power Supply Adapter for above Control Processor etc.

3

15477

46431

... More
Supply, Installation, Testing and Commissioning of 10.1” or above Touch Panel: fully configurable: IPS LCD based Capacitive Multi-Touch with LED backlighting: Should support Any-Color Side LEDs: Ambient Light Sensor: Built-in Zoom Rooms Controller, Book Scheduling, Web Kiosk: Adjustable Security Modes, Resolution (WH) Landscape: 1920x1200, Aspect Ratio (WH) Landscape: 16:10, Brightness 350 cd/m2, Contrast Ratio 800:1, RAM4 GB, storage 16 GB, Ethernet RJ-45, POE 802.3af, 15.4W, Speakers 2 x 2 Watt, Compliance: UL, CE, CB, FCC Class B (-5dB) etc.

3

216682

650046

... More
Supply, Installation, Testing and Commissioning of Tabletop Stand for above touch panel for desktop operations: should have the feature called as `Angle select` which allows to adjusted the position of a touch panel at a 30-, 45- or 60-degree angle from vertical etc.

3

30955

92865

... More
Supply, Installation, Testing and Commissioning of PoE Injector for above touch panel etc.

3

15477

46431

... More
Supply, Installation, Testing and Commissioning of 6 - 8 or more Button Keypad with volume knob: it should supplied with 3-Input Switching Wall plate Transmitter (2 HDMI, 1 USB-C) includes auto and manual switching modes, and support for transmission of uncompressed video and audio up to 40m/131ft at 4K or 70m/230ft at 1080P over shielded Cat 6/6A/7 cable: It should support supplied Multi-Function Receiver with Built-In 2x25W 4/8-ohm Amplifier, USB signal pass-through, RS232 control, Relay, IR, mic/line input, line out, remote mute, audio de-embedding, USB-AUDIO, ARC function, and CEC control (Embedded HD Base T™ technology allows for full usage of HDMI and controls over Cat 6/6A/7 cable). Web Configuration for simplified installation: should support OEM Specific Management PC tool included for campus wide room and device management etc.

2

162512

325024

... More
Supply, Installation, Testing and Commissioning of 4x4 Matrix Switcher, it should support Minimum 4 HDMI input and 4 HDMI output Should support computer and video resolutions up to 4K/60 4:4:4 or better: Should support HDMI 2.0 with a data rates up to 18 Gbps or more: Should support Front panel, IR, RS232 and Web based GUI control modes: Should support audio input format PCM 2-Channel, PCM Multi-Channel, Dolby Digital, Dolby Digital Plus, Dolby Atmos, Dolby True HD, DTS, DTS HD MA etc.

2

232159

464318

... More
Supply, Installation, Testing and Commissioning of wireless handheld microphone set with rack receiver having an automatic frequency and interference management, OLED display, Ethernet connectivity (IPv4 and IPv6), 256-bit AES encryption, Frequency range: 1,880 to 1,900 MHz, Frequency response: 20 to 20,000 Hz, Signal-to-noise ratio: ) 90 dB(A), RF output power: up to 80 mW or more, Dynamic range: ) 120 dB(A), Sampling rates: 24 bit/48 kHz, Connection: Audio Out: XLR 3M Audio Out: 2 x RCA Network: RJ 45 along with condenser type handheld transmitter with a super-cardioid pick-up pattern, sensitivity: 1.6 mV/Pa, Maximum sound pressure level: 152 dB, RF output power: up to 80 mW or more, operating time: 15 hour operation time. It should be remotely controlled with centralized software.

5

110471

552355

... More
Supply, Installation, Testing and Commissioning of wireless Lavalier microphone set with rack receiver having an automatic frequency and interference management, OLED display, Ethernet connectivity (IPv4 and IPv6), 256-bit AES encryption, Frequency range: 1,880 to 1,900 MHz, Frequency response: 20 to 20,000 Hz, Signal-to-noise ratio: ) 90 dB(A), RF output power: up to 80 mW or more, Dynamic range: ) 120 dB(A), Sampling rates: 24 bit/48 kHz, Connection: Audio Out: XLR 3M Audio Out: 2 x RCA Network: RJ 45 along with Wireless Bodypack transmitter with condenser type omni-directional clip-on microphone, Sensitivity: 20 mV/Pa, Maximum sound pressure level: 130 dB, RF output power: up to 80 mW or more, operating time: 15 hours. It should be remotely controlled with centralized software.

4

124249

496996

... More
Supply, Installation, Testing and Commissioning of 2 bay network charge, Remote Charging status Monitoring to OEM own software or third party controller, each bay should have 4 LEDs to indicate the corresponding battery status of the microphone, two hour or less for full charging, The charger shall have an RJ-45 network socket and shall support IPv4 and IPv6 network addressing.

5

29651

148255

... More
Supply, Installation, Testing and Commissioning of HDMI to USB converter.

3

61909

185727

... More
Supply, Installation, Testing and Commissioning of Metallic Audio Electronic Digital Podium, Display - High Sensitive, Built-In Speaker, Touch Type Monitor, Motorized Adjustable, Screen -Color Led: Scratch Resistant, Anti Glare and Vandal Resistant Glass, Size - 21.5 Inch Screen, Display Colors - 1 Billion Colors, Brightness - )450 Nits, Aspect Ratio(Typical) 16:9, Computer Interface - USB X1, HDMI X1, Response Time 8MS or better , Viewing Angle - 170 (H) 160 (V), Touch Technology- Infrared Technology - Console Panel Display Ports - HDMI, USB X1, RJ 45 X1, Type/Mounting - Free Standing, Adjustable Tilt, Body Type - CRCA Steel Sheet, All Directional Wheel With Lock, Small Form Factor, Gooseneck Mic, Processor - Intel Core i5 , Ram 8GB , SSD 256, Port - HDMI X 1, VGA X 1, USB 3.0 X 1, USB 2.0 X 2, LAN, Wi-Fi Inbuilt, Audio - Line-Out X 1/ Line-In X 1 Keyboard and Mouse Provided, O/S - Windows 10 Pro Preloaded, Central Controller With Panel And video Scalar Feature.

2

332858

665716

... More
Supply, Installation, Testing and Commissioning of Desktop Document Camera, 1/2.8` 8M CMOS Color Image Sensor, Pixels - 8.6 MP, Zoom - 30x, Resolution - XGA / 720p / 1080p / 2160p, Frame Rate - 30 fps for all resolution, Shooting Area Max. - 522 x 308 mm (20.5` x 12.1`), Input - HDMIx1 (Support 4K), HDMI Pass-Through, Output - HDMI2.0 x1 / VGA x1(up to 1080p) / USB 2.0 / IP Streaming, Control -RS-232 / USB / Ethernet, Supports HDMI, VGA, Ethernet, and USB output, Standalone Audio Video Recording on USB Drive, In-built Mic, Top Light x 2, In- built Backlight for X-rays, Negatives, Slides etc. OEM should be BIS, CE, RoHS and FCC Certified.

1

172727

172727

... More
Supply, Installation, Testing and Commissioning of 19` Integrated LED LIFT with Touch screen , Screen 1920 X 1080 LED Widescreen, Screen thickness – 15mm, Screen Structure – Toughened glass in Front and black aluminum frame, Motor power – 18W 220V 50/60 Hz, Interface – VGA/HDMI Input, Door opening method- Upward opening door elevation angle: 12 degrees elevation, Control Mode- manual control, Remote control, 485 center control, Central control interface- Rs485 input and output.

1

98022

98022

... More
Supply, Installation, Testing and Commissioning of Multiview with streaming solution for Video Conferencing with 4 x HDMI inputs and 1 x HDMI and 1 x USB 3.0 outputs supporting 18Gbps (600MHz) 4K UHD support, Seamless switching with no loss of sync to display when switching sources in 4x2 matrix mode, supports to store a multi-window arrangement as a preset, EDID management, Supports easy adjustment of window size, position and settings in the PiP windowing mode via the Web GUI and controllable via front panel buttons, Web GUI, Telnet, RS-232. Ability to automatically scales 4K sources to 1080p for USB capture with video timing stabilization to help ensure a reliable and stable USB capture stream, should support capturing 2 channel digital audio from either HDMI (LPCM 2.0) or the 3.5mm analog audio input (selectable via capture software). Compliance with the UAC (USB Audio Class) and UVC (USB Video Class) standards to support most common capture and video streaming.

1

387163

387163

... More
Variable Refrigerant Flow System :- Supply Installation Testing and Commissioning of Variable Refrigerant Flow air cooled Outdoor Units suitable for cooling and heating, having all hermetically sealed inverter type Scroll / Twin rotary Compressor(s) , microprocessor based controller, top discharge type condensing units with R410 A refrigerant , vibration isolators with suitable foundation etc. complete as required. The Outdoor unit should have anti corrosive, fins along with auto dust removal as a standard feature. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 Deg C ambient temperature without tripping. The unit shall be suitable to work on 400 V plus /-10% 3 phase , 50 Hz AC power supply. The COP at AHRI in Cooling mode should not be less than 4.0 and IEER 7.2 at 100% . Each ODU whether connected in module to make bigger ODU should have Same make Compressor. 24 HP (Two or More ODU Unit)

19

554259

10530921

... More
4- Way Cassette indoor unit :- Supply Installation Testing and Commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve ,outer cabinet, drain pump grill, necessary supports, vibration isolation, corded/Cordless remote control etc suitable for operation on 230 V plus - 10% 50 Hz AC supply. 4.0 TR Cassette A/C (With Sensing Panel)

15

57629

864435

... More
4- Way Cassette indoor unit :- Supply Installation Testing and Commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve ,outer cabinet, drain pump grill, necessary supports, vibration isolation, corded/Cordless remote control etc suitable for operation on 230 V plus - 10% 50 Hz AC supply. 3.0 TR Cassette A/C (With Sensing Panel)

7

55830

390810

... More
High Static Ducted Units :- Supply Installation Testing and Commissioning of following minimum capacity High Static VRV/VRF Ducted Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve ,outer cabinet, drain pump grill, necessary supports, vibration isolation, corded/Cordless remote control etc suitable for operation on 230 V plus - 10% 50 Hz AC supply. 8.2 TR Ductable A/c

5

101155

505775

... More
Supply, installation, testing and commissioning of factory fabricated Double Skin weather proof, outdoor type, Air- handling unit horizontal type fabricated out of extruded aluminium section consisting with 0.63 mm pre-plasticized/pre-coated Galvanised steel sheet outside and 0.63 mm plain galvanised steel sheet inside with blower, blower section, fan motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, Multi Row deep cooling coil made of Aluminium finned Copper tube with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90%, stainless steel drain pan made out of 18 G sheet duly insulated complete with motor and belt drive package etc. The AHU panels with thermal break profile insulated with (50±2) mm thick and 40 ± 2 Kg/m³ density PU foam. The motor and blower assembly shall be mounted on Aluminium extruded section only. The complete AHU shall conform to standard specification. Constructional Features of DOUBLE SKIN TYPE HORIZONTAL FLOOR MOUNTED AIR HANDLING UNITS. ? Mixing box with manually operated fresh and return air AL dampers. ? Filter section with 50 mm thick box type pre-filter. ? Coil section with multi-rows deep DX type cooling coil. ? Fan section with SISW centrifugal direct driven plug fan,with VFD Unit and spring isolators. ? Supply air manually operated AL damper. 29500 CFM / with AHU kit as per OEM Design.

2

1733554

3467108

... More
Refrigerant Piping :- Supply installation Testing and Commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for F/VRV system, complete with fittings, with suitable adjustable ring type hanger supports, ng/brazing including accessories insulated with XLPE Class O tubular insulation/with Class O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories.Size 12.70mm OD

400

1197

478800

... More
Supply and fixing of following thickness duly laminated aluminium foil finish closed cell Nitrile rubber ( Class O) insulation on duct after applying suitable adhesive for Nitrile rubber . The joints shall be sealed with 50 mm wide and 3mm thick self adhesive nitrile rubber insulation complete as per specifications and as required. (a) 19 mm thick insulation with Aluminium foil.

2484

585

1453140

... More
Supply and Laying 4.0 core x 10 Sq.mm copper conductor armoured cable complete in all respect to entire satisfaction of Engineer-in-charge.

75

796

59700

... More
Supply of Laying of 4 core 6 mm Sq copper cable complete in all respect to entire satisfaction of Engineer-in-charge.

100

450

45000

... More
Supply, Installation, Testing and Commissioning of Rodent System having following specifications: - Microprocessor based Main Panel / Controller wall mounting type with facility to connect 20 Transducers Operating Frequency ) 20Khz and ( 60 Khz. with 4 frequency bands Front Facia having LCD display and on board controls to view and operate the menu. Panel to be with power supply supporting 230V AC. Panel to have BMS Compatibility. (Up To 24 TRANSDUCERS ) TRANSDUCERS (12 nos.), BRACKETS (MS POWDER COATED), Standard 2 core 0.5sq. Mm PVC insulated wire complete in all respect.

1

163935

163935

... More
Supply, Installation, Testing and Commissioning of Video wall having screen size 29 x 11 Feet The pixel pitch should be 2.5 mm or better. The LED type is SMD 3 in 1. The LED configuration shall be 1 Red, 1 Green, 1 Blue. The cabinet design shall be fan less. The pixel density shall be 160,000 pixels per square meter or more. The half-gain horizontal and vertical viewing angles shall be H 150° and V 150° or better. The refresh rate shall be =3840 Hz or better. The grayscale processing shall be 16-bit or higher. The brightness shall be 800 cd/m² or higher, calibrated. The maximum power consumption during LED start-up shall be 347 W/sqm or lower. The average power consumption shall be 120 W/sqm or lower. The Video Inputs- HDMI 2.0 HDMI 2.0 (w/ HDCP 2.2) X 2, Display Port X 1, Outputs - RJ45/ Fiber Optics, The dimming capability shall have 256 levels. The operating temperature shall be 0°C to 40°C. The working humidity is 10% RH to 80% RH, The rated voltage shall be AC-230V±10% at 50/60Hz. The contrast ratio shall be 5000:1 or better. The access for maintenance shall be from the front. The IP level shall be IP20 or better. The lifespan shall be 100,000 hours or more. LED spares of 5% (modules) shall be provided at the time of delivery. Mandatory certifications CE, FCC, BIS, and UL, ISO 9001:2015, ISO 14001, ISO 45001. OEM must have a operational service center in state/ city from last 5 years, The mounting structure shall be made of MS or aluminum as per site requirements, 100% maintenance-free, with design flexibility, unaffected by humidity and water, durable to impact, requiring no polishing, and including fasteners or clamps. The brightness of the active LED Video wall of 800 nits must be measured by the OEM in the presence of the Engineer-in-Charge at the site using a luminance meter that gives output in cd/sqm or nits, not in Lux. Bidder must have to submit the ink signed MAF from respective OEM.

1

7945000

7945000

... More
SITC of Main Electrical Panel (CPRI Approved manufacturer at leat 70 K) INCOMING SUPPLY : MCCB 630 Amps 65 KA 4 Pole Micro Processor Based Adjustable Type with Rotary Mechanism and all Protections along With Spreader Links etc: 1 No Multi Fuction VAF/VIF Meter (96mmX96mm Size), Indication Lamps LED Type RYB, Control MCB SP for Control (3 Nos.) CT`s 600/5 (3Nos) and Control Terminal (8.0Nos) etc. Outgoing 20 No. 40-63 Amp TPNL MCCB with Adjustable Release 50 KA with ROM and Spreader Links S/c, O/L and Other Protections Outgoing for 24 HP ODU (12HP plus 12HP) All starter shall have following accessories : 1 No. overload relay, 1 No. Ammeter with CTs., 1 No. single phase preventer, 2 Nos. ON/OFF indicating lights, 2 Nos. ON/OFF push buttons, Hardware (PVC Channels/MCB Channels/Fibre-Glass/Gaskits/Sleeves/nuts/Bolts/washers/cooling fans/etc) Complete Wiring inclusive of thimbles,etc upto entire satisfaction of Enigneer-In-Charge of the work., The panel drawing shall be approved before taking up the fabrucation and shall have compitable BMS for future requiremnt.

2

723563

1447126

... More
SITC of DOL Starter (15KW), Outdoor Type. With Indication LED Lamps, On and Off Switch With Allied Accessories Items For AHU Unit, complete in all respect to entire satisfaction of Engineer-in-charge.

4

57746

230984

... More
CAR PARK VENTILATION SYSTEM Supply, installing, testing and commissioning of Analog type Carbon Monoxide based Gas detection system comprising of CO sensors, with DDC controller, built in power supply units. Detectors shall be mounted in enclosure with sensor lid projection at distance not more than 1500 mm from floor and shall have suitable arrangement to fix on wall or on ceiling as directed including SS 304 grill of size (200 x 150 x 125 mm) for protection. Sensor shall have range of 0-250 ppm non linear sensing, sensors shall be solid state type with operating temperature range of -10 to 50 deg C and relative humidity of 10% to 100% [noncondensing]. Enclosure shall be in minimum IP 55 construction. Seperate MS Powder Coated Junction Box shall be provided near each sensor for termination of armoured copper cable and final terminal inside sensor with flexible copper cable and IP 65 PVC glands . The Cost of CO senser , cabling , Conduit and supporting shall be included in this item . The CO senser location and technical details shall be approved by Consutlant based on design submitted by HVAC Vender. complete in all respect to entire satisfaction of Engineer-in-charge.

9

40520

364680

... More
Supplying, installation, testing and commissioning of ceiling hung / floor mounted vane/tube axial flow fans of following capacity with GSS casing/ standard M.S. construction and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency IE2 for Emergency Supply, Pressurization and Smoke Exhaust Fans and IE3 for Normal Supply, and Exhaust Fans suitable for 3 Phase 50 Hz 415V ± 10 %. Motor shall be class `F` insulation for Fresh Air and Pressurization Fans and class `H` insulation for Exhaust Fans. Fire rated flexible connection etc. including all accessories complete as required and as per specifications. Motor of exhaust fans shall be of high temperature resistance `Class H Smoke Spill` 250° C for 2 hrs., Complete fan shall be AMCA certidied for Air and sound performance and CE listed in accordance in EN 12101-3:2015 All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating/Powder coating after phosphating process and complete with bird screen at inlet with louver and fan protection coul. Suitable TP isolator within MS enclosure should be provided. Gravity louvers will be provided at the discharge of the fan so as to avoid reverse flow. Static pressure shall be checked/verified by contractor prior to order. Complete as required as per site conditions.18500 CFM / 18 MMWC TSP - For Fresh Air

2

139406

278812

... More
Supplying, installation, testing and commissioning of ceiling hung / floor mounted vane/tube axial flow fans of following capacity with GSS casing/ standard M.S. construction and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency IE2 for Emergency Supply, Pressurization and Smoke Exhaust Fans and IE3 for Normal Supply, and Exhaust Fans suitable for 3 Phase 50 Hz 415V ± 10 %. Motor shall be class `F` insulation for Fresh Air and Pressurization Fans and class `H` insulation for Exhaust Fans. Fire rated flexible connection etc. including all accessories complete as required and as per specifications. Motor of exhaust fans shall be of high temperature resistance `Class H Smoke Spill` 250° C for 2 hrs., Complete fan shall be AMCA certidied for Air and sound performance and CE listed in accordance in EN 12101-3:2015 All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating/Powder coating after phosphating process and complete with bird screen at inlet with louver and fan protection coul. Suitable TP isolator within MS enclosure should be provided. Gravity louvers will be provided at the discharge of the fan so as to avoid reverse flow. Static pressure shall be checked/verified by contractor prior to order. Complete as required as per site conditions. 18500 CFM / 18 MMWC TSP - Exhaust Air

2

169024

338048

... More
Supplying, installation, testing and commissioning of ceiling hung / floor mounted vane/tube axial flow fans of following capacity with GSS casing/ standard M.S. construction and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency IE2 for Emergency Supply, Pressurization and Smoke Exhaust Fans and IE3 for Normal Supply, and Exhaust Fans suitable for 3 Phase 50 Hz 415V ± 10 %. Motor shall be class `F` insulation for Fresh Air and Pressurization Fans and class `H` insulation for Exhaust Fans. Fire rated flexible connection etc. including all accessories complete as required and as per specifications. Motor of exhaust fans shall be of high temperature resistance `Class H Smoke Spill` 250° C for 2 hrs., Complete fan shall be AMCA certidied for Air and sound performance and CE listed in accordance in EN 12101-3:2015 All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating/Powder coating after phosphating process and complete with bird screen at inlet with louver and fan protection coul. Suitable TP isolator within MS enclosure should be provided. Gravity louvers will be provided at the discharge of the fan so as to avoid reverse flow. Static pressure shall be checked/verified by contractor prior to order. Complete as required as per site conditions.22500 CFM / 18 MMWC TSP - For Fresh Air

2

174620

349240

... More
Supplying, installation, testing and commissioning of ceiling hung / floor mounted vane/tube axial flow fans of following capacity with GSS casing/ standard M.S. construction and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency IE2 for Emergency Supply, Pressurization and Smoke Exhaust Fans and IE3 for Normal Supply, and Exhaust Fans suitable for 3 Phase 50 Hz 415V ± 10 %. Motor shall be class `F` insulation for Fresh Air and Pressurization Fans and class `H` insulation for Exhaust Fans. Fire rated flexible connection etc. including all accessories complete as required and as per specifications. Motor of exhaust fans shall be of high temperature resistance `Class H Smoke Spill` 250° C for 2 hrs., Complete fan shall be AMCA certidied for Air and sound performance and CE listed in accordance in EN 12101-3:2015 All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating/Powder coating after phosphating process and complete with bird screen at inlet with louver and fan protection coul. Suitable TP isolator within MS enclosure should be provided. Gravity louvers will be provided at the discharge of the fan so as to avoid reverse flow. Static pressure shall be checked/verified by contractor prior to order. Complete as required as per site conditions. 22500 CFM / 18 MMWC TSP - FOR Exhaust Air

2

221410

442820

... More
Supply, installing, testing and commissioning of Jet Fan shall be provided with Dual Speed smoke spill motor with class `H` insulation for smoke extraction.Complete fan alongwith motor shall be suitable for operation on 415±10% volts, 50Hz, 3 phase AC power supply and capable to withstand 300 deg C temperature for a minimum duration of 2 hours. The Impeller of jet fan shall be Airfoil design with High efficiency blades.Jet Fans shall be made in single piece and shall supplied with silencers and fan should be within the silencer to avoid air, sound leakage .Fan shall be AMCA Certified for Air and Sound Performance. The fan shall be tested and certified for (F300) CE/UL Certified for smoke control and exhaust applications in accordance with EN 12101-3:2015 from notified body. Note: The motor make of smoke/exhaust fan shall be same as mentioned on the fire certificate of the fan provided by international independent laboratory under certifying authority. Quantity and location of jet fans will be finalized based on CFD analysis. complete in all respect to entire satisfaction of Engineer-in-charge.

9

79110

711990

... More
SITC of Preparation and approval of CFD (Computational Fluid Dynamics) Analysis in Basement Zone. CFD analysis to decide the correct location and quantity of jet fans. CFD analysis will be carried out for both normal and fire mode ventilation situation considering 6/12 ACPH, airflow strategy and control strategy to confirm the operation logic. CFD analysis will model all the cars, car parking bays, beams, structures, columns, voids, shafts, ramps, proposed fresh air route, fresh air shaft, exhaust air shaft and preliminary location of jet fans shown in the drawing. CFD output will give complete simulation of ventilation scheme not limited to velocity profile, temperature profile, smoke temp and movement profile, CO level profile, air movement profile. The number of repeat simulations shall be carried out until satisfactory results are achieved. complete in all respect to entire satisfaction of Engineer-in-charge.

1

40520

40520

... More
Supply, fabrication, installation and testing the flexible connections of fire resistance flexible double canvas sleeve as per the approved shop drawings. complete in all respect to entire satisfaction of Engineer-in-charge.

100

2701

270100

... More
Supply, installation, testing and commissioning of package type/unitized 11kV / 433 V Outdoor sub-station, 800kVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation. Vacuum Interrupter, RMU, LT panel switchgear and CSS enclosure shall be of same make to ensure life cycle optimization. Make: Siemens/Schneider Infrastructure/ABB. Note: CSS shall be from OEMs only. Licensed System Integrators are not allowed to supply. Package substation will have the following equipment:- HT SWITCHGEAR: - 11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of 2 nos. fixed manual operated Load Break Switch and 1 nos. fixed manual operated Vacuum Circuit Breaker Module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No. Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil. Capacitive voltage indication fixed type system with LED SF6 Gas pressure indicator. Padlocking facility. Protection CT shall be minimum 60/1A, 2.5VA, 5P10. - 3 nos. Operating Sequence of VCB shall be O-0.3sec-CO-3MIN-CO LBS module will have FPI. All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set TRANSFORMER: - 800 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer with corrugated wall, without conservator, type of design and Top Bushings for HT and LT with On Load Tap Changer of rating plus 10% to -10% @1.25%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date) Max Losses @ 50% Load 2147W and Max Losses @ 100% Load 5837 W and Impedance of 5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (Make of transformer: - NUCON/POWER STAR/DANISH/ As per OEM approved brands/ UHBVN/ DHBVN approved) - One No. Winding Temperature Indicator with Alarm and trip Contact LT PANEL: - LVS PANEL 2000 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. : LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER FROM TRANSFORMER: - 1600 Amps 433V 4P 50Hz 50KA EDO Air Circuit Breaker Ics=Icu=Icw=50 KA for 1 second based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases Multifunction meter of class 0.5 accuracy. - 1 No. All Civil works such as PCC/RCC foundation, Platform, Filling trench and pedestal etc as per CSS manufacturer`s recommendation are included in scope of work. OUTDOOR ENCLOSURE: - Outdoor type enclose of 1.5 mm (For non load bearing members) and 2.0 mm (For load bearing members) thickness having modular construction of Galvanized Sheet Steel in suitable design for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT and LT switchgear compartment and IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitably handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment. Vacuum Interrupter, RMU, LT panel switch gear and CSS enclosure shall be of same make to ensure life cycle optimization.

2

5477510

10955020

... More
Supply, Installation, Testing and Commissioning of Ceiling Hung Supply Air Axial flow fans of 20 mm WG static pressure complete with GSS casing, aluminium alloy impellers, directly driven by TEFC induction motor suitable at 415±10 % V,50 Hz, 3 Phase AC power supply, 1400 RPM, supporting frame,louvers, weld mesh inlet guard, TP isolator with MS enclosure box as required. Axial fans shall be AMCA and third party certified and should have rated motor and fan of Class- F complete in all respect to entire satisfaction of Engineer-in-charge. 32000 CFM

2

281798

563596

... More
Supplying, Installation, Testing and Commissioning of Floor standing Exhaust Air Axial flow fans of 20 mm WG static pressure complete with GSS casing, aluminium alloy impellers, directly driven by TEFC induction motor suitable for 415 V ± 10 %, 50 Hz ,3 Phase, 1400 RPM, supporting frame, Gravity louvers, weld mesh inlet guard, TP isolator with MS enclosure box as required etc. Axial fans for smoke ventilation shall be AMCA and third party certified and should have fire rated motor and fan of Class- H suitable for working at high temperature (250 deg. C for minimum 2 hrs.) complete in all respect to entire satisfaction of Engineer-in-charge. 32000 CFM

2

337663

675326

... More
Supplying, Fixing, Testing and Commissioning of motorised fire dampers in supply air duct, return air duct as and where required inclusive of control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed/opened in the event of fire signal complete as required. complete in all respect to entire satisfaction of Engineer-in-charge. Actuator

4

12372

49488

... More
Supply, Installation, Testing and Commissioning of Indoor type (T.T.A. PANEL) as per IEC/IS 61439- Part 1 and 2 Automatic Power Factor Correction panel (with detuned reactors) - 250KVAR. Supply, installation, testing and commissioning of powder coated (treated with 9 tank phosphating) with approved colour compartmentalized cubicle MV Panel fabricated out of 14/16 SWG thick CRCA sheet steel suitable for operation on 415 Volts, 50Hz, 3 Phase 4 wire AC supply . The panel shall be indoor free standing, floor mounting, dust and vermin proof type, adequate size cable alley with front operated rotary handles for MCCB`s complete with gland plates, lifting hooks, ventilating louvers, bus bars, Inter connections, earthing, labeling electrical interlocking , suitable for termination of cables as per single line diagram including. Supply and fixing of following switchgear and accessories complete as required. A separate earth copper bus bar of size 25 mm x 5 mm to be provided throughout the length of the panel complete with both Electrically interlocking foolproof system. The Panel should be extendable type. All accessories included in the panel cost such as rotary handles, Spreader link and its accessories and metering and capacitor feeder etc. as mentioned. The panel should be got inspected / tested in the factory premises from the Engineer-in-charge / consultant before brought at site after approval of all drawings of the panel. ( Make of Panels :- Schneider / ABB / Siemens / LandT / Sudhir Power / Tricolite / Advance Power Control System / Milestone / Trisquare ) CAPACITOR PANEL 250 KVAR shall comprise of following as mentioned :- MCCB 630 Amp TP 50KA complete with Spreader , Rotary Handle, Voltmeter with VSS , Ammeter with ASS , RYB Indication Lamp LED = 3 OS., 400/5Amp. 15 VA CL-1 Current Transformer = 3 NO. 06Amp. Control SP MCB = 8 NO. , 12 stage APFC relay, Control Contactors etc. Each capacitor feeder shall consists of 14% detuned reactor , Heavy duty capacitor ( rated at 525 volt ) , capacitor duty contactor as per capacitor , Selector switch , On / Off indicator with Push buttons , MCCB ( 36 KA ), MCB (10 ka ) for capacitor rating less than 15 KVAR . Panel shall be made to work in auto as well as manual mode. Capacitors banks shall be 5 KVAR - 1 NOS. , 10 KVAR - 1 Nos. , 15 KVAR - 1 NOS. , 20 KVAR - 1 Nos. , 25 KVAR - 2 Nos. , 50 KVAR - 3 Nos. Panel shall have 600 amp aluminium bus bar ACCESSORIES Fabrication in 2mm CRCA Sheet Powder Coating in Siemens Gray Shade, 75x40mm.Channel Base Frame, Cable Entry will be Top and Bottom Suitable for Cable, Lock, Rubber Gasket, hardware etc. Aluminium Main Bus Bar, Load wise Sub Feeder Bus Bar Colour Coated Heat Shrink Bus Bar sleeves Nut-Bolt, Washer, Hardware etc. WIRING and ACCESSORIES Power and Control Wiring will be (ISI 1100V) flame smoke FRLS PVC Single Core Copper Wire, Copper Lugs, PVC Sleeve, Ferrules Numbers, Hardware and Labour etc. Net capacitor rating shall be 250 KVAR @ 440 Volt.

2

675325

1350650

... More
Supply, Installation, Testing and Commissioning of Indoor type (T.T.A. PANEL) as per IEC/IS 61439- Part 1 and 2, with Aluminium TPN electrolytic grade Busbar 2000 Amp self standing indoor cubical main control confirming to IEC/IS 61439-1 and 2 specification for cubical panel fabricated out of 2mm thick CRCA sheet having with base frame made of 75 x 40 mm channel duly powder coated with shade of choice (pre treated with 9 tank pre treatment process). The panel shall have fire suppression system complete with tubes and cylinder duly filled. The panel should be complete in all respect as desired by the Engineer in charge of the work. ( Make of Panels :- Schneider / ABB / Siemens / LandT / Tricolite / Advance Power Control System / Milestone / Trisquare ) Incomer Supply- From 800 kVA PSS (1 and 2 ) - 2 nos. each comprising of = 1 sets ACB 4 pole 1600 Amp., EDO Ics=Icu=Icw=50 KA for 1 second with microprocessor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases (MP-LSIG Release), 415 volts complete Set, Shunt Release 220V AC, Under Voltage Release, Aux. Block, Interlocking System, Control MCB 6A SP.10KA `C` Curve., Aux. Contactor, display for energy parameter with percentage loading of graph, last 10 trip history and ZSI, individual fault indicator, Digital Multifunction Meter, Digital Volt meter 0-500V, MCB 20/2Amp / SP for Control, Breaker Control Switch, Indication Lamp LED Type for RYB, LED Lamp 220V for ON / Off/Trip, CT`s - 1600/5, for Metering and APFCR with CT Shorting Links, Panel Light with accessories, Cooling Fan plus MCB and other accessories etc. Incomer Supply From DG ( 1 ands ) - 2 nos. each comprising of 1 Sets ACB 4 pole 1250 amp., EDO with MP-LSIG Release, 415 volts complete Set, Shunt Release 220V AC, Under Voltage Release, Aux. Block, Interlocking System, Control MCB 6A SP.10KA `C` Curve, Aux. Contactor, Digital Multifunction Meter, Digital Volt meter 0-500V, MCB 20/2Amp / SP for Control, Breaker Control Switch, Indication Lamp LED Type for R,Y, B, LED Lamp 220V for ON / Off/Trip, CT`s - 1600/5, for Metering with CT Shorting Links, Cooling Fan plus MCB and other accessories etc. Bus coupler = 1 Set ACB 4 pole 1250Aamp., EDO with MP-LSIG Release, 415 volts complete, Shunt Release 220V AC, Under Voltage Release, Aux. Block, Interlocking System, Control MCB 6A SP.10KA `C` Curve., Aux. Contactor, Breaker Control Switch, MCB 6Amp / SP for Control., LED Lamp 220V for ON / Off/Trip. Outgoing Feeders- 1:-6 nos. 630A TP MCCB (36kA) with built-in Microprocessor Based Release (O/C, S/C) each comprising of spreader link, Rotary Handle. Digital Multifunction Meter with RS-485 communication port, Accuracy Cl.-1 (96mmX96 mm), 3 nos. CT - 600/5A, 5VA, Cl.-1 for Metering (Resin Cast) , 3nos. Indicating Lamps - ON, OFF,TRIP (220-240V AC), 4 nos. 6A SP Control MCB (10kA) C Curve, Outgoing Feeder 18 nos. each comprising of 100A TP MCCB (25kA) with TMD Based Release (O/C, S/C ) spreader link , extended rotary handle , Aux Contact , Digital Multifunction Meter with RS-485 communication port, Accuracy Cl.-1 (96mmX96 mm) , 3 nos. CT - 100/5A, 5VA, Cl.-1 for Metering (Resin Cast) , 3 nos. Indicating Lamps - ON, OFF, TIRP (220- 240V AC), 4 nos. 6A SP Control MCB (10kA) C Curve. The Panel shall be complete with all the interconnections, interlocking of incomer’s aluminium bus bar connections etc. Panel shall be complete with PLC based auto load management with DG synchronization ( DEIF based AGC 150 relay - 2 Nos. ) including necessary control contactors, relays, timers, push buttons, control logic, commissioning on site etc.

1

4705029

4705029

... More
SITC of Electrical Motor Control panel (MCC), made out of 2mm CRCA sheet finished with Grey Powder Coated painting with IP55 degree of protection comprising of incoming MCCB , Amp metering, outgoing feeders with MCB, Motor Starters DOL/ star delta starter comprising of contactors, relays, pushbutton station facility for remote Operation through push buttons/ BMS, Auto manual switches and safety devices complete at basement level. The panels shall be designed to suiting the requirement of Car parking Ventilation logic at all basements as per Technical Specifications and SLD. GA Drawing, SLD and Control Logic of panels to be submitted and approved prior to fabrication. Vendor shall verify the motor ratings as per the fan make /model selected and make necessary modifications as necessary) or single speed Exhaust Fans and Dual Speed Jet Fans. The single point incoming power will be supply by Electrical vender upto fan Electrical Panel. Further distribution shall be in scope of HVAC vender. (Including Panel, jet fan incoming power and communication cable, cable tray, conduit, panel) . (including all accessories) Incomer - 25 KW Outgoing - 7.5 KW X 2 Nos for Exhaust Fans. Outgoing – 2.0 KW X 5 Nos for Jet Fans.

2

92813

185626

... More
Supply and charging of Refrigerant Gas R- 410 for Top up in all respect as per requirement.

432

1157

499824

... More
SITC of Grille/Diffusers/Dampers of Aluminum with powder coating for Lift Lobby pressurization system with necessary civil work as per drawings and specifications complete in all respect upto entire satisfaction of EIC.

14.4

11715

168696

... More
Providing and fixing motorized volume control damper with necessary civil work as per drawings and specifications complete in all respect upto entire satisfaction of EIC.

16.88

11711

197690.63

... More
SITC of TFA ID unit (1500 CFM, 6RD/8RD 65sp) complete in all respect including the cost of all material required for installation like supports, brackets and controller etc. upto the entire satisfaction of Engineer in charge.

2

164791

329582

... More
Supply, installation, testing, and commissioning of CO2 monitoring system, inclusive of CO2 sensors and centralized controller, complete with wiring and accessories for minimum 16 sensors, as per specifications and approved drawings complete in all respect to entire satisfaction of Engineer-in-charge.

1

304543

304543

... More
Supply, installation, testing and commissioning of Copper conductor cables PVC sheathed, armoured cables of 1.1 KV grade with copper lugs and flameproof brass compression glands on both the ends with inhibting compound and GI earthing, identification tags, clamps and saddles etc. (I) 4Cx 10 Sqmm Copper Armoured

380

797

302860

... More
SITC of RGBW LED PAR: Light Source: 54x3 W RGBW LEDs Lamp life: 50,000 hrs, Input Voltages: AC90-260V 50/60Hz, Power Consumption:. 170W, Strobe: high speed white color or color changing strobe with 1-13Hz frequency range, Dimmer: 0-100% electronic dimming Light Angle: 25°, Control: DMX512, master-slave and sound activated or auto operation, Channels: 7 DMX channels USITT DMX-512, Other Functions: LED display, IR Remote control (optional), automatic operation with built-in programs, efficient low noise cooling system IP20, Finish - Black, Certification: CE complete in all respect to entire satisfaction of Engineer-in-charge.

16

24970

399520

... More
SITC of Video wall LED controller to maintain aspect ratio of 29 feet by 11 feet video wall screen with following specifications complete in all respect to entire satisfaction of Engineer-in-charge. 1 Architecture Server Based architecture 4U 2 Operating System Windows 10 Pro or higher -64bit 3 RAM 16 GB 4 SSD 950 GB or higher x2 Hot Swappable 5 RAID RAID 1 6 Chip i7 / Xeon Processor 7 Power Supply Maximum Power Consumption 500W : Dual Redundant Power Supply 8 Output 4 with custom Resolution 9 Inputs 04 HDMI Inputs ( FHD) plus 4 VNC Sources 10 PCIe Should have at least 2 PCIe x16 physical slots or higher 11 Chassis 19` rack mount industrial chassis with front Lock 12 Unix/Linux Emulation Should be possible to display images from Unix/Linux workstation 13 Wall Management Software Software to be provided to manage the layout on the display WALL MANAGEMENT SOFTWARE 14 Scaling and display Software enable user to display multiple sources up to any size and anywhere on the display wall.( Pixel to Pixel ) 15 RS232, TCP/IP RS232 and TCP/IP support should be available for other interfaces 16 Remote Control Controller can be controlled by Remote PC through LAN with MAC OS / OSX and WINDOWS 17 Auto Source Detection Software should support for auto source detection 18 Layout Management Should support for Video, RGB, DVI, ,Internet Explorer, Google Crome, Desktop Application and Remote Desktop Monitoring Layouts19 Scenarios ` Software should able to Save and Load desktop layouts from Local or remote machines` 20 Layout Scheduler All the Layouts can be scheduled as per user convenience 21 Software should support auto launch of Layouts according to specified time event by user 22 Launch Application Software should able to Support 23 User friendly Software should be use friendly 24 WebUI Software should support Web Based UI: can be opened for layout control and Create New Layout on windows, android, MAC OS 25 Zoning Logical Division of Wall with ability to create layouts for specified logical zone without interference with other zone 26 Multiple Video Wall Software should be capable to control multiple video wall from same software 27 Licensing Software based licensing with lifetime license on same hardware 28 Upgradability Complete System should be capable to add Inputs/Outputs in future 29 Source Type Supported Hardware Inputs, Google Chrome, IE, Screen Scrapping,HTML5,RSSFEED,TICKER,RTP,RTSP,H.264/Video/Images 30 Certification / Compliance BIS , ROHS , CE etc

1

851250

851250



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.