Haryana Police Housing Corporation Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Haryana Police Housing Corporation - HPHC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date21 Nov 2024
Closing Date12 Dec 2024
Tender Amount₹ 21,81,78,689 
Notes
Download

Costs

  • EMD

    ₹ 43,64,000
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
[10.29.2]Providing and laying of chequered terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 2. Medium shade pigment using 50% white cement, 50% ordinary cement

331.43

793

262823.99

... More
[10.37.1]Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1. 25 mm thick

1003.41

790

792693.9

... More
[10.38]Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

29.94

836

25029.84

... More
[10.5]Providing and laying of screed of 40 mm thick cement concrete 1:8:16 to be laid below the topping.

7082

69

488658

... More
[10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

3023.56

2707

8184776.92

... More
[10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc.

540.99

2534

1370868.66

... More
[10.58]Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

2510.94

538

1350885.72

... More
[10.63.3]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 3. Size of Tile 800x800 mm

3054.75

1164

3555729

... More
[10.67.3]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 3. Size of Tile 800x800 mm

290.4

1181

342962.4

... More
[10.72]Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles.

3345.15

4

-13380.6

... More
[10.98]Providing and fixing Grass paver block of required strength and thickness on 25 mm thick compacted bed of sand and filling the joint with sand complete in all respect

399.57

1198

478684.86

... More
[11.17]Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge

20516

234

4800744

... More
[11.35]Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

1539.39

23

35405.97

... More
[11.46]Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 and II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls and ceiling at all floors and locations, finished in smooth line and level etc. complete.

25727.78

188

4836822.64

... More
[11.47.1]12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): 1. Flush Band

9681

2

19362

... More
[11.5.4]12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand)

358.17

104

37249.68

... More
[11.60]Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

4676.83

59

275932.97

... More
[11.64.1]Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer

23216.84

45

1044757.8

... More
[11.69.2]Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre

2130.46

22

46870.12

... More
[11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade.

1550.02

31

48050.62

... More
[11.94.1]Finishing walls with textured exterior paint of required shade : 1. New work (Two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

1687.24

136

229464.64

... More
[11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

2989.59

88

263083.92

... More
[12.102.1]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm

626

49

30674

... More
[12.102.2]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 100 mm

1886

43

81098

... More
[12.103.2]Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 2. Twin rubber stopper

172

52

8944

... More
[12.114]Providing and fixing of roller blinds on windows complete with material and labour complete with push up and down arrangement as per approved design / colour and Engineer-in-charge.

102.24

2087

213374.88

... More
[12.12.2]Providing and Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 2. 1.0 mm thick

2616

460

1203360

... More
[12.147]Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermiculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) all-round the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).

255

1229

313395

... More
[12.152]Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail and side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for separately).

151

7080

1069080

... More
[12.154]Providing and fixing glazing in fire resistant door shutters, fixed panels and partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, and special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity and radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW and EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm

51

34022

1735122

... More
[12.157.1.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)

875

350

306250

... More
[12.157.2.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)

22318

403

8994154

... More
[12.159.2]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 2. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

585.28

922

539628.16

... More
[12.162.2]Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. 2. 255 X 19 mm

582

268

155976

... More
[12.37.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

412

1400

576800

... More
[12.37.3]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 3. 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws

726.24

1316

955731.84

... More
[12.39]Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).

412

348

143376

... More
[12.42]Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).

412

81

33372

... More
[12.87.2]Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 2. Double strip (horizontal type)

602

23

13846

... More
[12.89]Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

172

701

120572

... More
[12.98.1]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm

660

201

132660

... More
[12.99.2]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 250x10 mm

639

84

53676

... More
[12.99.4]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 4. 150x10 mm

1585

62

98270

... More
[12.99.5]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 5. 100x10 mm

301

46

13846

... More
[13.10.1]Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1. 4.0 mm thick glass panes

280

539

150920

... More
[13.10.2]Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 2. 5.5 mm thick glass panes

150

794

119100

... More
[13.21.1]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 1. Door Frame of size 80mm x 50mm with 37mm wide single rebate for 35mm door shutter

2537.6

947

2403107.2

... More
[13.21.2]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 2. Door Frame of size 125mm x 60mm with 37mm wide double rebate for 35mm door shutter

4629

1240

5739960

... More
[13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

14774

83

1226242

... More
[13.30.1]Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 1. Hot finished welded type tubes

4302

105

451710

... More
[13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

509

396

201564

... More
[13.5.3]Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 3. 10 x 120 mm

2264

78

176592

... More
[13.9.2]Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3 mm and nuts and bolts complete. 2. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides

935

697

651695

... More
[20.24.6]Drilling and tapping cast iron pipe lines of all diameters and screwing in ferrule and connections 6. Ferrule size 40 mm

2

841

1682

... More
[20.26.1]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 1. 11.43 cm thick wall

100

164

16400

... More
[20.26.2]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wall

160

242

38720

... More
[20.28.1]Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repointing, replastering, replacing bitumen and colour or white washing where required. 1. 75 mm thickness of roof or floor

100

85

8500

... More
[20.28.2]Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repointing, replastering, replacing bitumen and colour or white washing where required. 2. 115 mm thickness of roof or floor

160

103

16480

... More
[20.29.5]Labour our fixing G.I. or W.I. pipe sleeve pieces in holes in walls, floors, and roofs rounds pipes including all cutting and wastage 5. 40 mm internal diameter of sleeve pipe

2

61

122

... More
[20.56.2]Providing and screwing in brass/Gun Metal ferrules drilling and tapping Cast Iron /D.I. /G.I. pipe lines of all diameters and connections including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in- Charge. (Excavation will be paid separately). 2. 10mm i/d ferrule

2

155

310

... More
[20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge.

54

1339

72306

... More
[21.100.2]Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect. 2. 100 mm dia pipe

169

638

107822

... More
[21.100.3]Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect. 3. 125 mm dia pipe

186

812

151032

... More
[21.93.1]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 1. Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening

10

1155

11550

... More
[21.93.2]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening

8

1058

8464

... More
[21.93.3]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 3. Type:- Extra Heavy Duty Set (EHD-10) 560MM Clear Opening

6

772

4632

... More
[22.10.2.1]Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 2.1. Kitchen sink without drain board 610x510 mm bowl depth 200 mm

20

2620

52400

... More
[22.101.2.1]Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore

128

51

6528

... More
[22.102.2]Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 2. 150 mm diameter

64

151

9664

... More
[22.103.3]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore

2

292

584

... More
[22.106.1]Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore

64

457

29248

... More
[22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore

128

444

56832

... More
[22.109]Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.

60

49

2940

... More
[22.119.2]Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 2. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

64

360

23040

... More
[22.14.1.2]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 1.2. Semi rigid pipe 40 mm dia

72

54

3888

... More
[22.166.3.1]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 3.1. 180x150 mm size P type With common burnt clay non-modular bricks of class designation 7.5

21

1593

33453

... More
[22.173.1]Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5

2

772

1544

... More
[22.185.1]Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 1. 50 mm dia

25

4412

110300

... More
[22.186.1]Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 1. 80 mm dia nominal bore

1

2708

2708

... More
[22.190.1.1]Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 1.1. Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay non-modular bricks of class designation 7.5

12

6580

78960

... More
[22.190.2.1]Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 2.1. Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay non-modular bricks of class designation 7.5

12

14563

174756

... More
[22.191.1.1]Extra for depth for manholes : 1.1. Size 90x80 cm With common burnt clay non-modular bricks of class designation 7.5

12

4077

48924

... More
[22.191.1.2]Extra for depth for manholes : 1.2. Size 90x80 cm With Sewer bricks conforming to IS : 4885

12

4130

49560

... More
[22.198.1]Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 1. With 20x20 mm square bar

96

243

23328

... More
[22.206.1]Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5

12

3284

39408

... More
[22.207.1]Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : 1. With common burnt clay non-modular bricks of class designation 7.5

14

5463

76482

... More
[22.218.1]Providing and Supplying of class SN 8 structured wall Polyethylene Piping system (Pipe with online/ offline coupler and elastomeric sealing ring) with non smooth external annular corrugated and smooth internal surface (double wall) for non-pressure underground sewerage and drainage application as confirm to IS 16098 (part II):2013 including transportation, frieght charges, inspection charges, loading, unloading, complete as specified and directed by Engineer In-Charge. 1. 250 mm Internal Diameter

429

442

189618

... More
[22.218.2]Providing and Supplying of class SN 8 structured wall Polyethylene Piping system (Pipe with online/ offline coupler and elastomeric sealing ring) with non smooth external annular corrugated and smooth internal surface (double wall) for non-pressure underground sewerage and drainage application as confirm to IS 16098 (part II):2013 including transportation, frieght charges, inspection charges, loading, unloading, complete as specified and directed by Engineer In-Charge. 2. 300 mm Internal Diameter

53

701

37153

... More
[22.218.3]Providing and Supplying of class SN 8 structured wall Polyethylene Piping system (Pipe with online/ offline coupler and elastomeric sealing ring) with non smooth external annular corrugated and smooth internal surface (double wall) for non-pressure underground sewerage and drainage application as confirm to IS 16098 (part II):2013 including transportation, frieght charges, inspection charges, loading, unloading, complete as specified and directed by Engineer In-Charge. 3. 400 mm Internal Diameter

10

1233

12330

... More
[22.22.1]Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1. White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

24

3493

83832

... More
[22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete

724.9

322

233417.8

... More
[22.222.2.3]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete

104

273

28392

... More
[22.33]Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.

32

10809

345888

... More
[22.38]Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.

33

241

7953

... More
[22.41]Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.

2

36

72

... More
[22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass

32

389

12448

... More
[22.83]Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.

90

138

12420

... More
[22.85.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes

694

311

215834

... More
[22.85.5]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 5. 40 mm nominal outer dia Pipes

473

430

203390

... More
[22.85.6]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 6. 50 mm nominal outer dia Pipes

307

648

198936

... More
[22.86.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes

729.53

264

192595.92

... More
[22.86.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes

145

333

48285

... More
[22.86.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes

120

429

51480

... More
[22.87.7]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 7. 62.50 mm nominal inner dia Pipes

115

1229

141335

... More
[22.87.8]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 8. 75 mm nominal inner dia Pipes

15

1582

23730

... More
[22.93.3]Providing and filling sand envelope of grading zone IV or coarser grade,100mm all-round the G.I. pipes in external work : 3. 25 mm diameter pipe

12

62

744

... More
[22.93.6]Providing and filling sand envelope of grading zone IV or coarser grade,100mm all-round the G.I. pipes in external work : 6. 50 mm diameter pipe

54

66

3564

... More
[22.96.1]Providing and fixing brass bib cock of approved quality : 1. 15 mm nominal bore

32

250

8000

... More
[23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA

2

6695

13390

... More
[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA

8

10809

86472

... More
[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA

1

20350

20350

... More
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA

35

6130

214550

... More
[23.22.4.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.10. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 6 way ( 8 incoming 3phase*6 outgoing)

5

7223

36115

... More
[23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing)

7

1406

9842

... More
[23.22.4.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.3. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 12 way ( 2 incoming and 10 outgoing)

34

1706

58004

... More
[23.22.4.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.6. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing)

4

3276

13104

... More
[23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)

5

3958

19790

... More
[23.22.4.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.8. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing)

4

5755

23020

... More
[23.22.4.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.9. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing)

22

6088

133936

... More
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole

680

145

98600

... More
[23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE

62

426

26412

... More
[23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole

34

677

23018

... More
[23.22.5.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.5. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs TRIPLE POLE

2

682

1364

... More
[23.22.5.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.7. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs FOUR POLE

27

910

24570

... More
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE

30

1291

38730

... More
[23.22.6.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.1. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 25 A

17

1478

25126

... More
[23.22.6.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.2. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 40 A

61

1670

101870

... More
[23.22.6.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.3. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 63 A

12

2075

24900

... More
[23.22.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 7. Supply and erection of blanking sheet in existing distribution board.

101

8

808

... More
[23.23.10]MISCELLANEOUS 10. Supplying and drawing of 1 no UTP 4 pair CAT 6a LAN Cable in the existing surface/recess MS/PVC conduit as required

5600

44

246400

... More
[23.23.6..2]MISCELLANEOUS 6..2. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 200 X 50 X 2 mm

70

351

24570

... More
[23.23.6.1]MISCELLANEOUS 6.1. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 100 X 50 X 2 mm

60

231

13860

... More
[23.23.6.3]MISCELLANEOUS 6.3. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 375 X 50 X 2 mm

60

397

23820

... More
[23.23.7.1]MISCELLANEOUS 7.1. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 100 X 50 X 2 mm

60

203

12180

... More
[23.23.7.2]MISCELLANEOUS 7.2. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 200 X 50 X 2 mm

70

340

23800

... More
[23.23.7.3]MISCELLANEOUS 7.3. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 375 X 50 X 2 mm metre

60

588

35280

... More
[23.24.3.8]MS STAND, BUS BAR CHAMBER AND PANELS 3.8. Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S. sheet and fixing with rag bolts on wall or on existing pedestal/angle iron frame including bonding, detachable top and bottom including painting and necessary connection etc. (Aluminium bars). 300 amp 4 bars of 55 cm each (cross section 51 mm x6 mm) chamber over all size 60 cm x 55 cm x 23 cm

2

5133

10266

... More
[23.24.4.1]MS STAND, BUS BAR CHAMBER AND PANELS 4.1. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 4 way 250 amp.

2

43169

86338

... More
[23.24.4.2]MS STAND, BUS BAR CHAMBER AND PANELS 4.2. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 8 way 250 amp.

3

52129

156387

... More
[23.24.4.3]MS STAND, BUS BAR CHAMBER AND PANELS 4.3. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 4 way 400 amp.

1

48467

48467

... More
[23.24.4.4]MS STAND, BUS BAR CHAMBER AND PANELS 4.4. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 8 way 400 amp.

1

56621

56621

... More
[23.27.5]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 5. M.S. pedestal of size 1200 mm wide ,1500 mm high ,450 mm deep and bottom totally open , duly embeded in cement concrete block of size 1350 mm x 600 mm x 200 mm above ground level , having a base of size 1500 mm x 750 mm x 250 mm below ground level . 0 0

1

12357

12357

... More
[23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)

800

88

70400

... More
[23.3.6.10]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.10. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 3 run of Size 2.50 Sqmm(1.1.80mm)

250

271

67750

... More
[23.3.6.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm)

750

113

84750

... More
[23.3.6.3]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm)

200

144

28800

... More
[23.3.6.4]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm)

650

172

111800

... More
[23.3.6.5]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm)

460

346

159160

... More
[23.3.6.6]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm)

150

135

20250

... More
[23.3.6.7]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.7. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 2.50 Sqmm(1.1.80mm)

750

193

144750

... More
[23.3.6.8]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.8. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 4 Sqmm(1/2.24mm)

300

259

77700

... More
[23.3.6.9]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.9. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 3 run of Size 1.50 Sqmm(1/1.40mm)

200

189

37800

... More
[23.4.1.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A

1254

520

652080

... More
[23.4.4.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.1. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A

629

725

456025

... More
[23.4.5.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.1. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A

253

999

252747

... More
[23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm)

230

109

25070

... More
[23.5.6.4]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm)

350

138

48300

... More
[23.5.6.5]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm)

294

310

91140

... More
[23.7.6.1]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia.

900

26

23400

... More
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.

6900

32

220800

... More
[23.7.6.4]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia.

200

57

11400

... More
[23.8.10.2]FITTING AND ACCESSORIES 10.2. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 Modules

181

127

22987

... More
[23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch

151

41

6191

... More
[23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate

130

18

2340

... More
[23.8.11.3]FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch

30

82

2460

... More
[23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket

151

82

12382

... More
[23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket

30

124

3720

... More
[23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt

244

257

62708

... More
[23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.

244

95

23180

... More
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.

80

730

58400

... More
[24.1.12]EARTHING AND LIGHTENING ARRESTOR 12. Supplying and laying 6 S.W.G G.I. wire at 0.50 m below ground level from earth electrode including thimbles, soldering etc. as required.

120

127

15240

... More
[24.1.14]EARTHING AND LIGHTENING ARRESTOR 14. Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size.

680

62

42160

... More
[24.1.16]EARTHING AND LIGHTENING ARRESTOR 16. Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers.

8

898

7184

... More
[24.1.17]EARTHING AND LIGHTENING ARRESTOR 17. Providing and fixing testing joints made of 20mm x 3mm thick G.I. strips 125 mm long with 4 nos. G.I. bolts and nuts with washers complete.

8

73

584

... More
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.

52

3368

175136

... More
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.

4

8275

33100

... More
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.

64

801

51264

... More
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.

250

360

90000

... More
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.

300

96

28800

... More
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.

80

730

58400

... More
[24.13.18]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 18. 10 Sq mm 4 core (Arm.)

160

148

23680

... More
[24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.)

390

180

70200

... More
[24.13.26]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 26. 25 Sq mm 2core (Arm.)

30

146

4380

... More
[24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.)

110

217

23870

... More
[24.13.38]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 38. 35 Sq mm 3.5 core (Arm.)

80

250

20000

... More
[24.13.54]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 54. 70 Sq mm 3.5 core (Arm.)

60

453

27180

... More
[24.13.62]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 62. 95 Sq mm 3.5 core (Arm.)

120

561

67320

... More
[24.13.82]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 82. 185 Sq mm 3.5 core (Arm.)

40

1011

40440

... More
[24.13.88]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 88. 240 Sq mm 3.5 core (Arm.)

50

1289

64450

... More
[24.13.94]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 94. 300 Sq mm 3.5 core (Arm.)

60

1574

94440

... More
[24.2.10]LT CABLE 10. Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S. Rod welded/riveted at the top with 10 cm dia 3 mm thick MS plate inscribed with cable word on it, having a cross arm 30 cm long of the same dia welded at the bottom, in exiting trench 45 cm below ground level.

30

240

7200

... More
[24.2.7.1]LT CABLE 7.1. Supply and erection of suitable compression type brass cable glands for underground Cable :- Up to 6 Sq mm cable 2 to 4 Core

50

32

1600

... More
[24.2.7.2]LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core

10

45

450

... More
[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core

14

77

1078

... More
[24.2.7.4]LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core

14

104

1456

... More
[24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core

8

133

1064

... More
[24.2.7.7]LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core

6

227

1362

... More
[24.2.8.11]LT CABLE 8.11. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 150 sqmm

16

40

640

... More
[24.2.8.12]LT CABLE 8.12. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 185 sqmm

16

49

784

... More
[24.2.8.13]LT CABLE 8.13. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 240 sqmm

16

71

1136

... More
[24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm

12

91

1092

... More
[24.2.8.2]LT CABLE 8.2. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 4 sqmm to 6 sqmm

250

4

1000

... More
[24.2.8.3]LT CABLE 8.3. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 10 sqmm

50

6

300

... More
[24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm

160

8

1280

... More
[24.2.8.5]LT CABLE 8.5. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 25 sqmm

60

10

600

... More
[24.2.8.6]LT CABLE 8.6. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 35 sqmm

40

11

440

... More
[24.2.8.7]LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm

12

15

180

... More
[24.2.8.8]LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm

20

20

400

... More
[24.2.8.9]LT CABLE 8.9. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 95 sqmm

16

23

368

... More
[24.5.1.5]MISCELLANEOUS ITEMS 1.5. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. Submersible Copper Cable 3 Core 10 sqmm

220

183

40260

... More
[25.3.2]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 2. 250 mm dia

22

15015

330330

... More
[25.3.4]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 4. 150mm dia.

2

4552

9104

... More
[25.6.2]Supplying, fixing, testing and commissioning o STRAINER flanged end and PN 16 pressure rating as specified. 2. 150mm dia.

2

8137

16274

... More
[25.7.1]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 1. Thickness 0.63 mm sheet

100

812

81200

... More
[25.7.2]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 2. Thickness 0.80 mm sheet

90

972

87480

... More
[25.7.3]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 3. Thickness 1.00 mm sheet

20

1175

23500

... More
[25.7.4]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 4. Thickness 1.25 mm sheet

10

1398

13980

... More
[26.58.1]Supply and installation of garden bench 1. Chair type garden bench with L-shaped sides made of reinforced concrete (M30), thickness 100 mm, overall height 1000 mm, base width 620 mm. Back and seat shall consist of 5 Nos. reinforced concrete planks 1500 mm x 100 mm x 50 mm one plank 1500 mm x 200 mm x 50 mm. Seating height of the bench shall be 450 mm. The bench shall be fixed with nuts on concrete mount, all holes sealed after assembly and installation. All materials required to be as per BIS specifications.

10

4814

48140

... More
[28.15]Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

1075.63

233

250621.79

... More
[28.6]`Providing and applying waterproofing treatment to sound, moisture free concrete surface using liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2 mm. It shall be applied in two coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties: 1) Elongation : )400% as per ASTM D 412 2) Tensile Strength : 2.5 N/mm2 as per ASTM D 412 3) Adhesion in-peel test : )50 N as per ASTM C- 836 4) Recovery from 350% elongation : 95% as per ASTM D 412 5) Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr 6) Initial Hardness Shore A : min 60 as per ASTM D 2240 7) Root resistant : protection screed required System includes supply , application and termination of coating all complete as per the manufacturer`s methodology. Clean the RCC slab/screed surface and wall for treatment by removing dust, dirt and layers of concrete over the surface. etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer`s recommendations. Prepare a side gola of 50X50 mm at the junction using polymer modified mortar. Providing and applying liquid applied single component pitch free polyurethane coating in 2 coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. (Fibre cloth/fleece/reinforcement should not be used in between two coats of PU as it has adverse effect on elongation property and also affects bonding with slab). Termination shall be done 300 mm above FFl by providing a groove cut of 30mm x 30mm and seal it with shrinkage compensated polymer modified mortar. Lay a 150 GSM geotextile layer to protect the coating from external damage on final coating before laying of screed concrete/final finish. It shall be applied as per manufactures specification. Rates are incl of surface preparation, grouting and chemical application only. (Rates for geotextile, protection plaster and final finishes such as screed or Brick bat filling for slope, china mosaic, tiles etc is not included in above item. It will be added as per EIC requirements).`

1733.83

694

1203278.02

... More
[29.1]Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.

1309

321

420189

... More
[29.2]Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, desiccants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.29.6) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, plus 12mm Air gap plus 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

119

2269

270011

... More
[29.3]Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.

23.8

2326

55358.8

... More
[29.4]Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm /sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminium sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.

23.8

1323

31487.4

... More
[29.5]Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevant Item).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

23.8

1425

33915

... More
[30.94]Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, up to 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal and vertical tubes joint with cup and lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.

6315.61

121

764188.81

... More
[31.14.1]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 1. 8mm dia (hole size 12 mm dia & depth up to 80 mm)

35

290

10150

... More
[31.14.2]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 2. 10 mm dia (hole size 14 mm.& hole depth up to 100 mm) 0 0

450

522

234900

... More
[31.14.3]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 3. 12mm dia (hole size 16mm.& hole depth up to 120 mm) 0 0

40

638

25520

... More
[31.14.4]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 4. 16mm dia (hole size 20 mm dia & depth up to 200mm) 0 0

100

812

81200

... More
[31.14.5]Rebarring work with 10ml inject able mortar epoxy adhesive (Hybrid Urethane Methacrylate adhesive) or chemical compound of make as approved by Engineer-in-Charge complete in all respect including drilling and cost of all materials 0 0 0 5. 20mm dia (hole size 24 mm dia & depth up to 240mm) 0 0

30

986

29580

... More
[32.47.2]Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance = 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 and7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre and 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 2. With 20 mm thick bevelled tegular mineral fibre false ceiling tile (NRC 0.7)

402.99

1465

590380.35

... More
[32.70.2]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 2. Above 10 kWp and up to 100 Kwp

16

42902

686432

... More
[4.1]Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.

4793.3

6

28759.8

... More
[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil

4849.7

78

378276.6

... More
[4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil.

615

83

51045

... More
[4.16.1.3]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.3. All kind of soil Pipes, cables etc, exceeding 300 mm dia but not exceeding 600 mm dia.

492

131

64452

... More
[4.31.1]Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 1. All kinds of soil

2473.75

51

126161.25

... More
[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

3200.8

46

147236.8

... More
[4.39]Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20%

2323.8

284

659959.2

... More
[6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

199.38

3476

693044.88

... More
[6.1.4]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 4. 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)

24.3

2911

70737.3

... More
[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

655.94

2442

1601805.48

... More
[6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

250.13

6113

1529044.69

... More
[6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level

1616.77

4464

7217261.28

... More
[6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level

2325.07

4502

10467465.14

... More
[6.26.1]Extra for providing richer mixes up to plinth and at all floor levels. 1. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)

1457.24

59

85977.16

... More
[6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete

844.62

156

131760.72

... More
[6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

678.07

282

191215.74

... More
[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform

7695.77

208

1600720.16

... More
[6.30.4]Centering and shuttering including strutting, propping etc. and removal of form for 4. Shelves (Cast in situ)

39.96

223

8911.08

... More
[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers

10618.84

296

3143176.64

... More
[6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts

5787.83

262

1516411.46

... More
[6.30.7]Centering and shuttering including strutting, propping etc. and removal of form for 7. Stairs, (excluding landings) except spiral-staircases

218.88

290

63475.2

... More
[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more

647019.37

66

42703278.42

... More
[6.61.2]Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminium base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical location in load application areas that accommodates multi directional seismic movement without stress to it`s components. System shall consist of metal profiles with a universal aluminium base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063). 2. Floor Joint of 150 mm gap

260.24

5559

1446674.16

... More
[6.62.2]Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminium base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings and complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminium profiles exhibiting minimal exposed aluminium surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 2. Wall Joint of 150 mm gap

55.2

4168

230073.6

... More
[6.63.2]Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminium base members with, self aligning and self centering arrangement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminium base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). 2. Roof Joint of 150 mm gap

65.06

4631

301292.86

... More
[6.8.2]Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 2. 40mm thick

352.47

133

46878.51

... More
[7.21.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement mortar 1:6 (1 cement : 6 coarse sand)

616.78

3968

2447383.04

... More
[7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand)

49.06

4488

220181.28

... More
[7.28.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand)

1224.02

488

597321.76

... More
[7.30]Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry.

1224.02

75

91801.5

... More
[7.50]Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor IV level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos. 6 mm dia M.S. bars at every third course of masonry work.

412.71

5054

2085836.34

... More
[7.51]Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately).

1281.31

4144

5309748.64

... More
[8.26.2.1]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.1. Granite of any colour and shade Area of slab up to 0.50 sqm

107.36

2750

295240

... More
[8.26.2.2]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shade Area of slab over 0.50 sqm

61.99

2776

172084.24

... More
[8.27.2]Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work

1115.5

230

256565

... More
[8.28]Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

114

393

44802

... More
[8.32]ALUMINIUM COMPOSITE PANELS Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis and design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metallic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material and labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item , as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminium Composite Panel Cladding (including width of groove) shall be measured in sqm up to two decimal places.

59.5

2475

147262.5

... More
[8.5]Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width up to 150 mm with epoxy resin based adhesive, including cleaning etc. complete.

78.33

189

14804.37

... More
[9.11.1]10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10

1733.83

488

846109.04

... More
[9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase

932.05

112

104389.6

... More
[9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

22

147

3234

... More
[9.46.3]Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 3. 12.5 mm thick tapered edge gypsum moisture resistant board

225.09

868

195378.12

... More
[9.47.1]Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 1. GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.

487.1

921

448619.1

... More
[9.57.3]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter

429.15

269

115441.35

... More
[9.58.1.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.3. Coupler 150 mm

68

118

8024

... More
[9.58.5.3]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5° 150 mm bend

44

129

5676

... More
NS PART Earth filling with earth brought from outside the campus, irrespective of any lead, including laying in 15cm in layers, watering and consolidating complete in all respect and fully satisfaction of Engineer-in-charge (Based on HSR 2021)

4431.6

343

1520038.8

... More
Providing and fixing towel ring of Jaquar make or equivalent complete in all respect

52

500

26000

... More
Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer-in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium corbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum densityof 650 kg/cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mm square hollow box section including applying a priming coat of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer- In- Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately.

239.28

2664

637441.92

... More
Extra for grouting the joints of floor tiles having joints of 4 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 800x800mm

3907.86

118

461127.48

... More
Supply Installation Testing and Commissioning of 65 Inch LED Display ,Resolution - 3,840 X 2,160 (UHD), Brightness (cd/m²) 400, HDR (10 Pro / HLG), Audio Output - 10W plus 10W, Speaker System - 2.0 ch, One Touch Sound Tuning, USB Cloning, WOL, SNMP, Diagnostics (USB), Sampling (HDMI-CEC (1.4)), IR Out (RS-232C), Multi IR Code, Voltage, Hz -AC 120 V ~ 50 / 60 Hz, Power Consumption(Typ.)-180.3W complete in all respect with petty material including making necessary connections upto entire satisfaction of engineer- in- charge of work.

1

78404

78404

... More
Providing and fixing UPVC SWR P-trap (DS) 110x110mm dia complete in all respect

123

274

33702

... More
Providing and fixing SWR PVC Nanhi trap with Jali (110x110mm)

22

256

5632

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

13

1181

15353

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS Sheet, 1200mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

2

15188

30376

... More
Supply and Erection of hose box double door (750x 600x 250mm) suitable for 2 nos. hose pipe 15 meter, 1 no. short branch pipe complete in all respect.

19

3656

69464

... More
Supply and erection of Fire Extinguisher ISI marked CO2 type of 4.5 Kg capacity as per IS :7285 duly erected/ hags on wall with hooks i/c the cost of hook, screws etc. with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer in charge of the work.

25

4894

122350

... More
Providing and fixing pressure gauges with all accessories complete in all respects.

4

731

2924

... More
Supplying and fixing _single headed internal hydrant valve with instantaneous Gunmetal/ Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Stainless steel

20

4331

86620

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 2 way-100 mm dia MS Pipe

1

4275

4275

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 4 way-150 mm dia MS Pipe

2

8775

17550

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required: 100mm dia

2

3881

7762

... More
Providing and Fixing of ABC Type 6 kg (Stored Pressure) Fire Extinguisher filled with Mono Ammonium Phosphate Powder MAP 50% Confirming to ‘IS 4308’, Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose and Nozzle and Epoxy Polyester Powder Coated Mild Steel body, Fire Extinguishers As per ‘IS 15683 : 2018’ ISI Marked. [3Q]

25

3488

87200

... More
Supply, and Erection of 10W LED Bulkhead light fixture with necessary driver lamp, connections, wiring and etc. complying to IP 65 class of protection complete as required.

68

638

43384

... More
Supply and erection of LED Light 36 Watt 2`x2` Size (Recessed Type) operation on single phase AC Supply complete in all respect up to the entire satisfaction of engineer- in charger of the work including making necessary connection.

62

2802

173724

... More
Supply and erection of LED Down Light 12 Watt 6``x6`` Size (Surface Type) operation on single phase AC Supply complete in all respect up to the entire satisfaction of engineer- in charger of the work including making necessary connection.

354

909

321786

... More
Supply and erection of LED batten 20 watt (4 feet long) operation on single phase AC supply complete in all respect up to the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. (3Q)

497

391

194327

... More
Supply and erection of 25 Ltr. commercial RO plus UV, Fully automatic with auto cut off RO plus UV Water Purification system 25 Itr/ hr capacity. (3Q)

12

23400

280800

... More
Supply and Erection of Split AC 1.5 TR 3 Star rating fixed speed split type air conditioning unit, with copper refrigerant pipe as supply by manufacture, complete with all labor and petty material required i/c making necessary connections up to entire satisfaction of Engineer-in-Charge of the work. (3Q)

2

33047

66094

... More
Supply and erection of Stabilizer 4 KVA 100 UP (150 Volt to 280 Volt) complete in all respected all labor and petty material. (3Q)

2

4481

8962

... More
Supply and erection of Stabilizer 5 KVA 100 UP (150 Volt to 280 Volt) complete in all respected all labor and petty material. (3Q)

12

6472

77664

... More
Supply and Erection of Outdoor stand (Heavy) as per Company complete in all respect. (3Q)

2

746

1492

... More
Supply and Erection of Copper Refrigerant Pipe for 1.5 Ton AC with insulation and 4.0 Sq mm 4 Core Wiring complete in all respect. (3Q)

40

979

39160

... More
Cutting chase in brick work for skirting flush with plaster

8638.4

28

241875.2

... More
Providing and fixing aluminium sliding door bolt 200x16mm

301

294

88494

... More
Providing and fixing aluminium sliding door bolt 150x12mm

301

159

47859

... More
Providing and fixing aluminium folding handle 100mm

1284

118

151512

... More
Providing and fixing CP brass flange of approved make complete in all respect

142

37

5254

... More
FIRST AID HOSE REEL:-Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve and nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket.

17

6535

111095

... More
Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: Stainless Steel (Grade 304)

38

1252

47576

... More
HOSE PIPE:-Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with Gl wire, rivets etc. conforming to IS 636 (type A) as required : Stainless Steel (Grade 304)

38

3351

127338

... More
P/F Soap Dish Holder (CAN-1131N) Jaquar make or equivalent

96

821

78816

... More
Providing and fixing SWR PVC Single T with door 110mm dia.

6

210

1260

... More
Providing and fixing SWR PVC Single T with door 90mm dia

16

179

2864

... More
Providing and fixing SWR PVC Single T 110mm dia.

62

182

11284

... More
Providing and fixing SWR PVC Vent cowl with Jali 110mm dia

6

83

498

... More
Providing and fixing SWR PVC Pipe clip/ Clamp 90mm dia

50

33

1650

... More
Providing and fixing SWR PVC Pipe clip/ Clamp 110mm dia

605

35

21175

... More
Providing and fixing SWR PVC Coupler/ Socket 110mm dia.

6

107

642

... More
Providing and fixing SWR PVC Coupler/ Socket 90mm dia.

32

89

2848

... More
Providing and fixing SWR PVC Bend with Door 110mm dia.

195

169

32955

... More
Providing and fixing SWR PVC Bend with Door 90mm dia.

32

148

4736

... More
Providing and fixing Zinc coated clamp i/c cost of 12mm screwed GI rod and fastener complete in all respect having dia 110mm/90mm..

660

245

161700

... More
Providing and fixing 32mm dia CPVC ball valve/gate valve (Union type) of approved quality complete in all respect.

32

371

11872

... More
Providing and fixing 40mm dia CPVC ball valve/gate valve (Union type) of approved quality complete in all respect.

32

609

19488

... More
Providing and fixing 25mm thick red sand stone both side slightly rounded for partition and shelves in CB

363.12

765

277786.8

... More
Providing and fixing in position best quality stainless steel sink (Glossy) with complete fitting Size 45” x 20” with 2 nos. bowls of size 20” x 16”,8”, Model DBF-02. Make Jayna or equipment

2

12312

24624

... More
Supply, Installation, Testing and comissioning of Basic IP Phone with 128 x 64 –pixel Graphical LCD (3.1 Inch). LED for Incoming/ Ongoing Call, Mute, Hold. 3 Feature Keys : Headset, Mute , Hands-free speaker phone. Volume Control Keys. Complete in all respect as per Directions of Engineer-in-Charge.

1

4869

4869

... More
SUPPLY AND ERECTION of water cooler SP body with 150 ltr/hr Cooling Capacity and 150 ltr storage capacity complete in all respect /c all labor and petty material. [3Q]

12

44312

531744

... More
Supply, Installation, Testing and Commissioning of Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54 having Rotary Decade Switches for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/UL.

16

4647

74352

... More
P/F Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever and Adjustable Wall Flange (CON-083FTK) Jaquar make or equivalent.

128

591

75648

... More
Providing and fixing 50mm dia CPVC union complete in all respect

20

341

6820

... More
Supply and Erection of 1.5 Sqmm x 3 core PVC insulated multi core copper conductor cable (unarmored) 1100 volts grade (round) in existing pole/ pipe, complete in all respect including making necessary connections

2200

65

143000

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 150mm diameter

60

2784

167040

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 100mm diameter.

360

1659

597240

... More
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 25 mm diameter.

20

535

10700

... More
Fabrication, supply, Installation , testing and commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, Compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : 5.1 INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Voltmeter 0- 500V with selector switch Digital Ammeter (0- 250 A) with selector switch and CTs etc. LED type RYB phase indicating lamps, ON, OFF, preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/ manual/ OFF operation.

2

32063

64126

... More
Supply, Installation Testing and Commissioning of auto glow exist sings and indication signs of size 12” x 4” and attack fire, DP indication at every exit point, fire point, fire extinguisher compete in all respect.

24

1350

32400

... More
Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the nonvolatile memory (EPROM), power supply unit (230 t 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for BMS system with open protocol BAC net/ Modbus over IP complete as per specifications: Ten Loop Panel

1

376875

376875

... More
Supplying, installation, testing and commissioning of addressable horn cum strobe complete as required.

16

2475

39600

... More
Providing and applying RCC bond for Gypsum plaster on RCC ceiling etc. complete in all respect.

16298.39

53

863814.67

... More
NS Item -Providing and fixing Glass Reinforced Concrete (GRC) moulding casted with `Spray Mix` concrete design in approved size, pattern, thickness of 40-50mm on the outer border and 15-20mm for internal member and shade. The moulding should be made from `43 grade` Portland Cement of approved brand white Quartz fine graded sieve silica sand, Alkali Resistant glass fibre of approved brand, super plasticizers of approved brand, polymers of approved brand and U.V. resistant synthetic inorganic pigments should be used for pgmentation of approved brand. The mould casting shall take place with layering methodology using- direct power spray machines. The GRC moulding flexural strength average LOP should be above or equivalent to 6N/mm2 and MOR should be above or equivalent to 12N/mm2 for tests done on 28 days cured samples. The fixing of mould should be done using ` Dry fixing` method onto structral support members i.e. RCC, Brick work MS framework. MS Galvanized clamps and PINS also if required fasteners to be used of Steel Grip/HP/Wurth/Hilti/Fischer/ Klimas or equivalent. If there will be a requirement of joints filling, then Elastomeric exterior grade hybrid paintable silicon sealant will be used for final finishing of moulding/ cornice/ column/ brackets one weather shield exterior grade water based diluted paint coat will be done if required vendors shall submit shop drawing of the same, the drawings to be duly approved by the Engineer in charge at site Unistone grass reinforced concrete (GRC) Moulding 75x50mm.

303.32

1674

507757.68

... More
Providing and fixing Glass Reinforced Concrete (GRC) moulding casted with `Spray Mix` concrete design in approved size, pattern, thickness of 40-50mm on the outer border and 15-20mm for internal member and shade. The moulding should be made from `43 grade` Portland Cement of approved brand white Quartz fine graded sieve silica sand, Alkali Resistant glass fibre of approved brand, super plasticizers of approved brand, polymers of approved brand and U.V. resistant synthetic inorganic pigments should be used for pgmentation of approved brand. The mould casting shall take place with layering methodology using- direct power spray machines. The GRC moulding flexural strength average LOP should be above or equivalent to 6N/mm2 and MOR should be above or equivalent to 12N/mm2 for tests done on 28 days cured samples. The fixing of mould should be done using ` Dry fixing` method onto structral support members i.e. RCC, Brick work MS framework. MS Galvanized clamps and PINS also if required fasteners to be used of Steel Grip/HP/Wurth/Hilti/Fischer/ Klimas or equivalent. If there will be a requirement of joints filling, then Elastomeric exterior grade hybrid paintable silicon sealant will be used for final finishing of moulding/ cornice/ column/ brackets one weather shield exterior grade water based diluted paint coat will be done if required vendors shall submit shop drawing of the same, the drawings to be duly approved by the Engineer in charge at site Unistone grass reinforced concrete (GRC) Moulding 300x250mm.

844.36

7582

6401937.52

... More
Providing and Fixing Fire Rated 5 Knuckle, 2 Ball bearing butt hinges size 4` x 3` x 3mm, in SS 304 and in SSS finish . Suitable for door weights upto 120kgs. Template Drilled Approved to EN 1935 , Durability - 200,000 Cycles, Corrosion Resistance - Very High as per direction of Engineer-in Charge. Fire Rated 2hrs. (Make - Dormakaba or equivalent).

312

321

100152

... More
Providing and Fixing Panic bar (Triple Point ) set for active leaf and 2 point locking panic bolt set on inactive leaf suitable for door width and height complete set with screws and fixing accessories Trim lever Latch Complete set including Spindle, screws and all fixing accessories 6 pin Euro profile half cylinder with one side key operation standard length 42mm in satin nickel plated finish with 3 keys. Optional master keying and grand master keying can be done on request reputed brand and manufacture.as per direction of Engineer-in Charge Fire Rated 2hrs. (Make - Dormakaba or equivalent).

38

20448

777024

... More
Providing and fixing rack and pinion door closer TS 71 or equivalent with adjustable closing force, size EN 3 or 4, Std. Arm closing speed adjustable in two independent ranges, with adjustable latching action. Non-handed. Approved to EN 1154,CERTIFIRE and CE Marked. Durability - 500,000 Cycles, Corrosive resistance - Moderate,Finish:Silver as per direction of Engineer-in Charge. (Make - Dormakaba or equivalent).

78

4361

340158

... More
Providing and fixing Surface mounted door coordinator for double doors , zinc plated for steel doors, non-Handed as per EN1158 and CE marked as per direction of Engineer-in Charge. (Make-Dormakaba or Equivalent).

38

7249

275462

... More
Providing and fixing floor stop half dome with 45mm dia with fixing accessories, in satin Chrome as per direction of Engineer-in-Charge. (Make - Dormakaba or equivalent).

78

260

20280

... More
Providing and fixing back to back with adjustable fixing for glass, wood and metal doors in satin stainless steel. The pull handles should have supporting washer with raised bevelling on the outer surface.CTC - 300mm, 22mm dia, Material - SS304, as per direction of Engineer-in-Charge. (Make Dormaka or equivalent).

2

1662

3324

... More
Providing and fixing Mortice dead lock with 55mm backset, 20mm square forend and prepared for euro profile cylinder including strike plate in satin stainless steel as per EN 12209, CE marked. Complete with EPC 70mm Length both side key operation and Escutcheons in SSS Finish.as per direction of Engineer-in-Charge. (Make - dormakaba or equivalent).

2

3886

7772

... More
Providing and Fixing Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws as per direction of Engineer -in-Charge

170

3921

666570

... More
P/F in position oval shaped under/ over counter wash basin make CERA including cost of 32mm dia C.P. waste complete in all respect.

52

1971

102492

... More
P/F Hand shower (Health faucet with 8mm dia 1 meter long flexible tube and hook (Model No.ALD-CHR-573) Make Jaquar or equivalent.

33

1269

41877

... More
Providing and Fixing Clay Façade Paneling system in approved shade, finish, size and in thickness of 15mm. The clay panels shall have Flexural Strength /Modulus of rupture = 9 N /mm2 in accordance to IS 15622:2017 E = 0,08 PERCENT (GROUP B IA) (CLAUSE 6) with breaking strength = 550 N in accordance to IS 5622:2017. The panels should have water absorption = 4 % in accordance to IS 13630. The surface scratch hardness value i.e., Moh’s scale should be Minimum 6 in accordance to IS 15622:2017 The clay panels should have inherent properties of being resistant to stains and chemicals. The material should be Class I material in terms of reaction to fire in accordance to EN 13501 -1 / ASTM E136. The entire system should be certified by an approved third- party structural consultant for a minimum structural proof load test with positive and negative wind pressure of 5kPA. The entire system shall weight approximately 35 kg per SQM. The cladding panels shall be fixed on to existing cured plastered surface substrate wall treated with one or two coats of primer with appropriate Aluminium rectangular hollow section vertical members framework of 25mm X 50mm (2mm thick) which shall be spaced out in accordance to the dimensions of the panel with minimum spacing of 600mm. The framework shall be attached through L shaped aluminium connectors of 25mm X 37mm (2mm thick) to the substrate walls. The manufactured panels shall have an evenly controlled factory – made groove for resting on to a continuous aluminium rail profiles throughout their length. The profiles are designed and manufactured for starter piece, intermediate and an inverted starter profile for the top piece. Aluminium rail profile shall ensure uniform and precision joints and shall be factory finished with Super Durable powered coated colour in approved RAL shade. All fixtures, and screws shall be corrosion free i.e., all rail profiles, cleats to be used should be made of 6063 T6 alloy grade and all screws used should be of Stainless steel of M/s Hilti, Worth, Klimas, Patta or equivalent. The groove of the width can be chosen i.e., 1.7mm, 3mm, 6.5mm, 12.6mm or 20mm. The corners junctions to be neatly treated with adequate aluminium closed ‘L’ corner shaped pieces in required length in similar shade coated with factory finished Super Durable Powder, to the clay façade panel. Alternatively, the corners junctions can be treated as regular corner fixing or Mitred corner fixing. All fixing details and drawings to be provided by vendor and to be duly approved by Engineer in charge at project and the work to be carried out as per direction of the Engineer- in charge. All fixing details and drawings to be provided by vendor and to be duly approved by Size : 600x1200mm and colour approved as per direction of Engineer in charge at project. (MAKE:- UNISTONE or EQUIVALENT).

3255.45

6438

20958587.1

... More
Supply, and Erection of 1200 mm sweep, BEE 5 star rated (BEE), ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 7.5, Air delivery minimum 225 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 8%, electronic regulator unit for speed control and all remaining accessories including safety pins, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete with minimum 24 months of warranty as required.

244

2644

645136

... More
Supply, Installation, Testing and Commissioning of Cat 6A SHIELDED TWISTED PAIR PATCH CORDS (1 Mtr): Conductors Should be of 4 twisted pairs of 26 AWG stranded copper for better flexibility, Patch cords should conform to ANSI/TIA-568-C.2 for Cat 6A, Should have RJ-45 jacks with boot at both the ends. Operating Temperature should be -25°C to plus 55°C, Shall be RoHS Compliant, Should be certified by ETL/UL.

170

398

67660

... More
Supply, Installation, Testing and Commissioning of Cat 6 A SHIELDED TWISTED PAIR PATCH CORDS (2 Mtr): Conductors Should be of 4 twisted pairs of 26 AWG stranded copper for better flexibility, Patch cords should conform to ANSI/TIA-568-C.2 for Cat 6A, Should have RJ-45 jacks with boot at both the ends. Operating Temperature should be -25°C to plus 55°C, Shall be RoHS Compliant, Should be certified by ETL/UL.

170

466

79220

... More
Supply, Installation, Testing and Commissioning of Cat 6A INFORMATION OUTLET (JACK): Should be conform to Category-6A as per ANSI/TIA-568-C.2,Should be support network line speeds up to 10 Gbps, I/O operating Life should be minimum 750 insertion cycles and contact material should be copper alloy. I/O contact plating should be 50µ Gold/ 50µ Nickel minimum, Operating Life should be minimum 750 insertion cycles, Plastic Housing must be Polycarbonate, UL94V-0 rated Should be RoHS Compliant, Should be certified by ETL/UL.

170

398

67660

... More
Supply, Installation, Testing and Commissioning of FACEPLATE(Dual):Single square plate, 86SMx86SM, Write on labels in transparent plastic window – supplied with plate, Screw hole covers – to be supplied with plate, Plug in Icons – Icon tree – to be supplied with plate, Should be able to support variety of jacks – UTP, FTP.

170

95

16150

... More
Supply, Installation, Testing and Commissioning of CAT 6 A 24 PORT Shielded JACK-k PANEL LOADED:-Should be supplied with individually replaceable 24 numbers Category-6A I/O shielded Jacks complying as per the ANSI/TIA-568C.2, Should be 19” rack mountable and of 1U height and complete with all mounting accessories, IDC Connector plastic housing should be polycarbonate and UL94V-0 rated. I/O contact plating should be 50µ Gold/ 50µ Nickel minimum, Should be RoHS Compliant, Should be certified by ETL/UL.

10

13298

132980

... More
Supply, Installation, Testing and Commissioning of Multi Mode fiber 6 core: -Unarmod Indoor, 50/125µm,OM4 LSZH Type Optical Fiber Cable: OFC consists of a number of 900µm tight buffered optical fibers reinforced with aramid yarns and sheathed in a flame retardant Low Smoke Zero Halogen (LSZH), Multi Mode, 50/125-micron primary coated buffers, OM4 (IEC 60793-2-50), Blue, Orange, Green, Brown, Slate (Grey), White, Red, Black, Yellow, Violet, Pink, Aqua, ISO/IEC 11801:2002 - 2nd Edition, Type OM4: AS/ACIF S008: AS/NZS 3080:2003, IEE 802.3ba: suitable for use in indoor / outdoor ducts, cabling, RoHS Complaint.

500

304

152000

... More
Supply, Installation, Testing and Commissioning of 24 port Fiber Optic Rack Mount LIU with Adaptors Plates ,Splice Tray and Pigtails:-LC-Style, Should be supplied loaded with secondary coated LC pigtails, Splice Tray and Splice Protector, Its compact design and high density capacity allows it to deliver carrier class fiber management to central offices, Pops, FTTX, mobile systems and LANs.1U: 24 Fiber terminations Upgradable Upto 96 LC port in 1 U.

6

10112

60672

... More
Supply, Installation, Testing and Commissioning of Fiber optic pigtails-Multi Mode Pigtails with LC connector, Type-50/125 micron fibre performance, Cordage Outer Diameter:2.0mm ±0.1mm x 4.1 ± 0.2mm, Buffer Diameter:-900µm,Primary Coating : 245µm, Attenuation-@ 850nm :- 3.0dB/km : @ @1300nm :- 1.5 dB/km, Jacket Material: LSZH, IEC 61034-1 and 2, IEC-60332-1, IEC-6075. Approved Make.

60

304

18240

... More
Supply, Installation, Testing and Commissioning of LC-LC Type 50/125µm Multimode OM4 Optical Fiber Patch Cords:-The optical fiber patch leads shall comprise of Multi-mode 50/125µm OM4 fiber with 2XLC type fiber connectors terminated at one end and 2X LC type fiber connectors at other end of the patch cord. (Duplex): 2.0mm ± 0.1mm x 4.1± 0.2mm, LS0H IEC 61034-1 and 2,IEC-60332-1, IEC-60754-1 and 2, -40 degree to plus 85 degree cent. ISO/IEC 1108:2008, ANSI/TIA/ EIA 568.C.3, ANSI/TIA/EIA-492, TELECORDIA GR-409, ICEA-596.

50

2643

132150

... More
Supplying and Fixing of Floor Standing  Network/Server Rack - 42U / 600w / 800d,  with Heavy Duty Extruded Aluminium Frame for rigidity.  Top cover with FHU provision. Top and Bottom cover with  cable entry gland plates.  Two pairs of 19” mounting  angles with ‘U’ marking. Depth support channels - 3 pairs.  With a Overall Weight Carrying Capacity of 500Kgs. Side Panels - 42U/800d  Front MS Door Perforated honeycomb 42U/600w  Rear MS Door Split Perforated honeycomb 42U/600wFan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Vertical Cable manager 80mmW 42U  Shelf, Stationery 700mm N/W  PDU 12Sockets 5/15Amps with MCB Mounting Hardware (Pkt. Of 20) earthing Kit 150mmH Cable manager 1U MS with Loops complete in all respect.

1

58384

58384

... More
Supplying and Fixing of Floor Standing Network Rack - 12U / 600w / 800d, with Heavy Duty Extruded Aluminium Frame for rigidity. Top cover with FHU provision. Top and Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capacity of 500Kgs. Side Panels - 12U/800d Front MS Door perforated honeycomb 12U/600w Rear MS Door (Fully Perforated - Mesh) 12U/600w Fan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Cable manager 1U MS with Loops Shelf, Stationery 475mm N/W PDU 7Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Vertical Cable Channel 50mmW 12U.

8

17807

142456

... More
Supply and installation Testing and Commissioning of Fixed 1RU chassis 24 PoE 1G Base T, 2 1G* RJ45/SFP plus combo, 2 1G/10G SFP plus uplink/VFL ports. Internal AC PSU (380W budget), stacking upto 4 switches, with 1 GB RAM and Flash and switching capacity 128 Gbps or better and forwarding rate 68 Mpps or better, 16 k Mac address, 4K VLAN and upto 1k multicast group with EAL2/NDCPP certified. includes country specific power cord, guides and 19` rack mount kit. *10G license upgradeable. As Per the detailed tender specs.

3

114968

344904

... More
Supply Installation Testing and Commissioning of Small Form Factor Pluggable 10 Gigabit optical transceiver SFP plus single Mode Fiber Module with an LC connector. Typical reach of 10Km.

4

21105

84420

... More
Supply and Installation Testing and Commissioning of Indoor Dual radio 2.4/5Ghz 2x2 802.11ax, omni antenna. 2x 1GE up, 1x RS-232 Console, USB, 48V DC, shall offer up to 1200 Mbps throughput on the 5Ghz band (low and high bands) and up to 573 Mbps throughput on the 2.4GHz band, DPI application, operating temperature from 0°C to 45°C with AP mount to be ordered separately. As per the detailed tender specs.

6

39555

237330

... More
Supply Installation testing and Commissioning of IP-PABX System: 03 Analogue Trunk 48 Hybrid Extension Including VOIP DB Card With the following Exclusive Features besides the Standard: Inbuilt CLI on KTS and PBT, Inbuilt Battery Charger, Inbuilt Music on Hold, Inbuilt Unsupervised Conference, Inbuilt External Call Forwarding, Inbuilt 8 IP Resources, Hybrid Extensions(Analog/Digital), Inbuilt Voice Mail/Auto attendant, Inbuilt 4 Party Web Based Video Conf Lic(Lan)

1

280212

280212

... More
Supply Installation Testing and Commissioning of IP Phone: Monochrome 132 x 48 LCD, LAN port and PC port, RJ9 headset jack (allowing EHS with Plantronics headsets), Support 1 SIP account, up to 2 call appearance.

2

5870

11740

... More
Supply Installation Testing and Commissioning of Analogue Phone: Speaker Phone,  Caller ID,30 Call Log, 5 Re-Dial memory, LCD (7 Segment 2 Line).

2

1665

3330

... More
Supply, erection, testing and commissioning of 20 passengers (G plus 3) Electrical Traction Elevator. Technical Specification and as per latest IS Specification. 1. Type :- Gearless Passenger Lift. 2. Stop/Opening :- 4 Stops and 4 Opening 3. Capacity :- 1360 Kg/ 20 Person 4. Speed :- 1.00 meter/Sec 5. Control :- High Performance Simplex Full Collective Control System 6. Driver :- AC VVVF Drive For More Power Saving Comfort and Safe Ride. 7. Floor :- G,1,2,3 8. Travel :- 11 meters (approx.) 9. Shaft Size :- 2500 mm wide x 2400 mm deep Overhead 5200 mm (Required) 1600 mm (Required) 10. M/C Position :- Gearless Machine shall be placed above the shaft in machine room 11. Car Area :- Inside 1600 mm Wide x 1900 mm Deep (3.04 Sq. meter) 12. Car Enclosure :- SS Scratch Resistant finish, Antiskid PVC flooring on heavy duty M.S plater form decorative false ceiling with CFL/LED lighting, blower/rotor Fan. 13. Clear Opening :- 1000 mm wide x 2000 mm Height. 14. Car Door :- Centre opening automatic door (Full vision glass door with SS frame) 15. Landing Door :- Center opening automatic door (Full vision glass door with SS frame) 16. Power Supply :- Three Ø 415 V AC, 50 Hz plus /- 5% Single Ø 230 V AC, 50 Hz plus /- 5% 17. Design :- These Components are generally confirmed as per Indian Standard Specification for Elevators or Escalators.

1

2613094

2613094

... More
Supply, erection, testing and commissioning of 13 passengers (G plus 3) Electrical Traction Elevator. Technical Specification and as per latest IS Specification. 1. Type :- Gearless Passenger Lift. 2. Stop/Opening :- 4 Stops and 4 Opening 3. Capacity :- 884 Kg/ 13 Person 4. Speed :- 1.00 meter/Sec 5. Control :- High Performance Simplex Full Collective Control System 6. Driver :- AC VVVF Drive For More Power Saving Comfort and Safe Ride. 7. Floor :- G,1,2,3 8. Travel :- 11 meters (approx.) 9. Shaft Size :- 2500 mm wide x 1900 mm deep Overhead 5200 mm (Required) 1600 mm (Required) 10. M/C Position :- Gearless Machine shall be placed above the shaft in machine room 11. Car Area :- Inside 1600 mm Wide x 1400 mm Deep (2.24 Sq. meter) 12. Car Enclosure :- SS Scratch Resistant finish, Antiskid PVC flooring on heavy duty M.S plater form decorative false ceiling with CFL/LED lighting, blower/rotor Fan. 13. Clear Opening :- 900 mm wide x 2000 mm Height. 14. Car Door :- Centre opening automatic door (Full vision glass door with SS frame) 15. Landing Door :- Center opening automatic door (Full vision glass door with SS frame) 16. Power Supply :- Three Ø 415 V AC, 50 Hz plus /- 5% Single Ø 230 V AC, 50 Hz plus /- 5% 17. Design :- These Components are generally confirmed as per Indian Standard Specification for Elevators or Escalators. `

1

1800844

1800844

... More
Supply, installation, testing and commissioning of NVR, 64 Channel , with Incoming and out going bandwidth of 320 Mbps each , 8 SATA port , with minimum 40 TB (4 X 10 TB) storage with below mentioned minimum features: supporting channel :64 channels Bandwidth :320 Mbps (Incoming)/320 Mbps (Outgoing) Recording Resolution: UP to 8 MP Video Output:1 or 2 HDMI Ports USB interface:1xUSB 3.0, 2XUSB 2.0 Raid :RAID 0/1/5/6/10 Minimum Storage :Minimum 8 SATA ports (Support up to 10TB Each SATA Port) Alerts: Generate alerts for camera or equipment malfunction and replacement, HDD failures, HDD tampering, etc Auto start/ Resume :should be capable of auto start/Resume operations post power fluctuation/ failure Access Management: Feature to limit access to storage data with access management Connectivity Interface:2 Nos. x 10/100/1000 Base-T Lan Port Backup and other Interface:1 e-SATA Port Protocols: NTP, SNMP Operating Condition:0°C to 55°C, humidity 80% (max) Alarms I/O: Minimum - 1 Alarm input ports and 1 Alarm Output Ports System Capability: Should be ONVIF Profile G, S and T Note: Quoted Model should be listed on ONVIF website and NVR OEM should not be blacklisted by ONVIF. Certifications :BIS Certified, UL/CE/FCC Additional feature :Auto sync - SD card to NVR, Auto resume ,VMS: Must have pre-loaded VMS, OnVIF complaint

1

196020

196020

... More
Supply, Installation, Testing and Commissioning of 5 MP DOME Camera 30 mtr IR with below mentioned minimum features: Type of Camera: Dome Image Sensor: 1/2.8 ` progressive Scan CMOS Resolution and frame rate: 5 MP @20fps OR Better Minimum Illumination: 0.05 Lux or better, F 1.6 or better Video Compression (Minimum): H.264, H.265, or better Wide Dynamic Range: Real/True WDR (120 db or more) Storage: Including 256 GB SD card- class 10 Audio Recording: Including Mic IR: 30 mtr. Or higher Network Protocol: TCP/IP, UDP, IPV4, IPV6, HTTPS, SNMP, DHCP Enclosure: IP67, IK10 Standards: BIS, UL/CE/FCC Power: PoE Reset Button: Required Lens Type: Lens Type: 2.8- 8 mm motorised lens or better or equivalent Lens: F 1.6 or better Signal-to-Noise Ratio: 50 dB or more System Capability: Should be ONVIF Profile G, S and T Note : Quoted Model should be listed on ONVIF website and CCTV OEM should not be blacklisted by ONVIF. Operating Condition: 0 °C to 55°C, humidity 80% (max) VMS Support: Camera shall support open-source VMS Additional Features: Defog, BLC Video Analytics: Motion Detection, Tampering Video Encryption: AES/TLS/SRTP NDAA Compliant: Yes

34

16038

545292

... More
Supply, Installation, Testing and Commissioning of 5 MP BULLET Camera 30 mtr IR with below mentioned minimum features: Type of Camera: Bullet Image Sensor: 1/2.8 ` progressive Scan CMOS Resolution and frame rate: 5 MP @ 20fps OR Better Minimum Illumination: 0.05 Lux or better, F 1.6 or better Video Compression (Minimum): H.264, H.265, or better Wide Dynamic Range: Real/True WDR (120 db or more) Storage: Including 256 GB SD card- class 10 Audio Recording: Including internal and External Mic IR: 30 mtr. Or higher Network Protocol: TCP/IP, UDP, IPV4, IPV6, HTTPS, SNMP, DHCP Enclosure: IP67, IK10 Standards: BIS, UL/CE/FCC Power: PoE Reset Button: Required Lens Type: Lens Type: 2.8- 8mm or better motorized lens Lens: F 1.6 or better Signal-to-Noise Ratio: 50 dB or more System Capability: Should be ONVIF Profile G, S and T Note : Quoted Model should be listed on ONVIF website and CCTV OEM should not be blacklisted by ONVIF. Operating Condition: 0 °C to 55°C, humidity 80% (max) VMS Support: Camera shall support open-source VMS Additional Features: Defog, BLC,HLC Video Analytics: Motion Detection, Tampering Video Encryption: AES/TLS/SRTP NDAA Compliant: Yes

10

17820

178200

... More
Supply, erection, testing and commissioning of LIFT-ERD/online UPS system For 13 Passenger Lift with following details : Lift motor load:10.8Kw, Rated current: 31.7A, 3Phase in 3Phase Out, With inbuilt isolation transformer, Micro controller based IGBT technology, Advanced technology: DSP based controller for power and monitoring, True online dual conversion design. Battery Backup for 15-20 mins, A. 30nos.*12V/42AH 30Kva. Heavy duty angle iron racks plus UNINVYN fire retardant copper battery interlinks.

1

468563

468563

... More
Providing and fixing in position 5mm thick looking mirror bevelled on sides fixing in position with necessary C.P. screws and washer and PVC moulding etc. complete

61.5

2565

157747.5

... More
Supply, Installation, Testing and Commissioning of 2 KVA Online UPS Overvoltage cut-off device (OVCD), with minimum 42 AH external battery cabinets, Generator Compatible with Wide Input. Wide Input Voltage window (110 – 280Vac) for Indian Environmental Condition and for Optimized Battery Performance. UPS would support SNMP Manager and web browser On Line With 1 hour Backup.

1

58320

58320

... More
Supply, Installation, Testing and Commissioning of Dry Scrubber (with centrifugal fan as per manufacturer standard) each comprising of extract air intake section, electrostatic precipitation technology, dry type air cleaner to remove oil, smoke and fumes from exhaust air, as per the Specifications. Supply, fabrication, installation and testing the flexible connections constructed painted MS Frame of fire resistance flexible double canvas sleeve.

10

2672

26720

... More
Supply, Installation, Testing and Commissioning of Dry Scrubber (with centrifugal fan as per manufacturer standard) each comprising of extract air intake section, electrostatic precipitation technology, dry type air cleaner to remove oil, smoke and fumes from exhaust air, as per the Specifications. Supplying, installing and testing of Exhaust Air powder coated Anodized extruded aluminium construction fresh air louvers ,bird screen and rattle-free.complete

9

12825

115425

... More
Supplying, installation, testing and commissioning of ceiling hung / floor mounted vane/tube axial flow fans of following capacity with GSS casing/ standard M.S. construction and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency IE2 for Emergency Supply, Pressurization and Smoke Exhaust Fans and IE3 for Normal Supply, and Exhaust Fans suitable for 3 Phase 50 Hz 415V ± 10 %. Motor shall be class `F` insulation for Fresh Air and Pressurization Fans and class `H` insulation for Exhaust Fans. Fire rated flexible connection etc. including all accessories complete as required and as per specifications. Motor of exhaust fans shall be of high temperature resistance `Class H Smoke Spill` 250° C for 2 hrs. All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet with louver and fan protection coul. Suitable TP isolator within MS enclosure should be provided. Gravity louvers will be provided at the discharge of the fan so as to avoid reverse flow. Static pressure shall be checked/verified by contractor prior to order.Complete as required as per site conditions. Air Quantity : 6000 CFM

4

37406

149624

... More
Supplying, installation, testing and commissioning of ceiling hung / floor mounted vane/tube axial flow fans of following capacity with GSS casing/ standard M.S. construction and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency IE2 for Emergency Supply, Pressurization and Smoke Exhaust Fans and IE3 for Normal Supply, and Exhaust Fans suitable for 3 Phase 50 Hz 415V ± 10 %. Motor shall be class `F` insulation for Fresh Air and Pressurization Fans and class `H` insulation for Exhaust Fans. Fire rated flexible connection etc. including all accessories complete as required and as per specifications. Motor of exhaust fans shall be of high temperature resistance `Class H Smoke Spill` 250° C for 2 hrs. All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet with louver and fan protection coul. Suitable TP isolator within MS enclosure should be provided. Gravity louvers will be provided at the discharge of the fan so as to avoid reverse flow. Static pressure shall be checked/verified by contractor prior to order.Complete as required as per site conditions. Air Quantity : 11000 CFM

3

53438

160314

... More
Supply, Installation, Testing and Commissioning of once through type air cooling unit with double stage cooling, double skin air handling units of GSS pre coated sheet metal, cabinet type, modular construction. Unit frame work shall have aluminium extrusion finish Rockwool insulation(Density not less than 50kg/m3) thickness of 44 plus /- 1 mm. The panels shall be of double-skinned construction with outer and inner skin being of pre coated GI Sheet. The unit panels skin thickness should be not less than 0.8 mm for outer skin and 0.6 mm for inner skin. All panels shall be sealed (anti fungicide sealant material) against the framework. The Panel shall be mounted flush with the frame members to create smooth surface inside and outside. (Note:The units under 20000 CFM capacities can also have 23mm PUF panels.) Unit shall be complete with air inlet chamber with 100% Fresh air Intake louvers and filter section with 50 mm deep min of G4 flange type washable filters on the other side. 1st STAGE SENSIBLE COOLING: Cooling section consisting of Sensible heat exchanger complete with cartridges made of Engineering polymer with thermally fused non woven heat exchange.The entire heat exchanger shall be placed above water tank of min 250 mm height, MOC SS 304, 1.2 mm thickness.The pump shall be submersible type recirculation water pump (XYLEM make) with level indicator and dry run protection incorporated in the PLC. One spare pump should be provided with unit. The UV treatment unit shall be provided to keep the water germ/bacteria free with Internal piping and accessories of U-PVC. The tank should be provided with quick fill connection with float valve, unit drain (ping pong type drain trap), marine light of IP-65 grade. 2nd STAGE ADIABATIC COOLING: This section shall consist of heat exchanger of cellulose paper pads and of cross fluted configuration assembled in self-supporting pads in a light weight construction. The pads shall be able to redistribute the water and shall be impregnated with insoluble antiriot salts, rigidifying saturates and wetting the entire surface completely. The velocity across the fill shall not exceed 450 fpm (2.3 m/s) and shall not allow carry over of water. Minimum thickness of fill shall be 200 mm and minimum efficiency of pads 90%. One bend PVC mist eliminator shall be provided after the adiabatic cooling section. Unit can be blow through (Push through) type. In case the unit is blow through, secondary fan will not be required. The capacity specified as per the manufacturer. The unit should have Auto drain with timer. Cable entry gland (1No for DOL and 2Nos for Star Delta) shall be provided on the AHU casing. It should be sealed after all the cabling work is done. Fan section complete with DIDW backward curved centrifugal/SISW Plug type fans (NLT 75% efficiency) mounted on common base frame, belt/direct driven by IE3 TEFC motor, 4P/6P suitable for Industrial type VFD operation. The blower and drive assembly should be protected with belt guard and door guard of perforated GI screen (half door size). Anti vibration spring type/rubber mount isolators for blower shall be considered. (a) 4000 CFM,70 mm ESP

1

235125

235125

... More
Supply, Installation, Testing and Commissioning of once through type air cooling unit with double stage cooling, double skin air handling units of GSS pre coated sheet metal, cabinet type, modular construction. Unit frame work shall have aluminium extrusion finish Rockwool insulation(Density not less than 50kg/m3) thickness of 44 plus /- 1 mm. The panels shall be of double-skinned construction with outer and inner skin being of pre coated GI Sheet. The unit panels skin thickness should be not less than 0.8 mm for outer skin and 0.6 mm for inner skin. All panels shall be sealed (anti fungicide sealant material) against the framework. The Panel shall be mounted flush with the frame members to create smooth surface inside and outside. (Note:The units under 20000 CFM capacities can also have 23mm PUF panels.) Unit shall be complete with air inlet chamber with 100% Fresh air Intake louvers and filter section with 50 mm deep min of G4 flange type washable filters on the other side. 1st STAGE SENSIBLE COOLING: Cooling section consisting of Sensible heat exchanger complete with cartridges made of Engineering polymer with thermally fused non woven heat exchange.The entire heat exchanger shall be placed above water tank of min 250 mm height, MOC SS 304, 1.2 mm thickness.The pump shall be submersible type recirculation water pump (XYLEM make) with level indicator and dry run protection incorporated in the PLC. One spare pump should be provided with unit. The UV treatment unit shall be provided to keep the water germ/bacteria free with Internal piping and accessories of U-PVC. The tank should be provided with quick fill connection with float valve, unit drain (ping pong type drain trap), marine light of IP-65 grade. 2nd STAGE ADIABATIC COOLING: This section shall consist of heat exchanger of cellulose paper pads and of cross fluted configuration assembled in self-supporting pads in a light weight construction. The pads shall be able to redistribute the water and shall be impregnated with insoluble antiriot salts, rigidifying saturates and wetting the entire surface completely. The velocity across the fill shall not exceed 450 fpm (2.3 m/s) and shall not allow carry over of water. Minimum thickness of fill shall be 200 mm and minimum efficiency of pads 90%. One bend PVC mist eliminator shall be provided after the adiabatic cooling section. Unit can be blow through (Push through) type. In case the unit is blow through, secondary fan will not be required. The capacity specified as per the manufacturer. The unit should have Auto drain with timer. Cable entry gland (1No for DOL and 2Nos for Star Delta) shall be provided on the AHU casing. It should be sealed after all the cabling work is done. Fan section complete with DIDW backward curved centrifugal/SISW Plug type fans (NLT 75% efficiency) mounted on common base frame, belt/direct driven by IE3 TEFC motor, 4P/6P suitable for Industrial type VFD operation. The blower and drive assembly should be protected with belt guard and door guard of perforated GI screen (half door size). Anti vibration spring type/rubber mount isolators for blower shall be considered. (b) 5000 CFM,110 mm of ESP

1

267188

267188

... More
Supply, Installation, Testing and Commissioning of once through type air cooling unit with double stage cooling, double skin air handling units of GSS pre coated sheet metal, cabinet type, modular construction. Unit frame work shall have aluminium extrusion finish Rockwool insulation(Density not less than 50kg/m3) thickness of 44 plus /- 1 mm. The panels shall be of double-skinned construction with outer and inner skin being of pre coated GI Sheet. The unit panels skin thickness should be not less than 0.8 mm for outer skin and 0.6 mm for inner skin. All panels shall be sealed (anti fungicide sealant material) against the framework. The Panel shall be mounted flush with the frame members to create smooth surface inside and outside. (Note:The units under 20000 CFM capacities can also have 23mm PUF panels.) Unit shall be complete with air inlet chamber with 100% Fresh air Intake louvers and filter section with 50 mm deep min of G4 flange type washable filters on the other side. 1st STAGE SENSIBLE COOLING: Cooling section consisting of Sensible heat exchanger complete with cartridges made of Engineering polymer with thermally fused non woven heat exchange.The entire heat exchanger shall be placed above water tank of min 250 mm height, MOC SS 304, 1.2 mm thickness.The pump shall be submersible type recirculation water pump (XYLEM make) with level indicator and dry run protection incorporated in the PLC. One spare pump should be provided with unit. The UV treatment unit shall be provided to keep the water germ/bacteria free with Internal piping and accessories of U-PVC. The tank should be provided with quick fill connection with float valve, unit drain (ping pong type drain trap), marine light of IP-65 grade. 2nd STAGE ADIABATIC COOLING: This section shall consist of heat exchanger of cellulose paper pads and of cross fluted configuration assembled in self-supporting pads in a light weight construction. The pads shall be able to redistribute the water and shall be impregnated with insoluble antiriot salts, rigidifying saturates and wetting the entire surface completely. The velocity across the fill shall not exceed 450 fpm (2.3 m/s) and shall not allow carry over of water. Minimum thickness of fill shall be 200 mm and minimum efficiency of pads 90%. One bend PVC mist eliminator shall be provided after the adiabatic cooling section. Unit can be blow through (Push through) type. In case the unit is blow through, secondary fan will not be required. The capacity specified as per the manufacturer. The unit should have Auto drain with timer. Cable entry gland (1No for DOL and 2Nos for Star Delta) shall be provided on the AHU casing. It should be sealed after all the cabling work is done. Fan section complete with DIDW backward curved centrifugal/SISW Plug type fans (NLT 75% efficiency) mounted on common base frame, belt/direct driven by IE3 TEFC motor, 4P/6P suitable for Industrial type VFD operation. The blower and drive assembly should be protected with belt guard and door guard of perforated GI screen (half door size). Anti vibration spring type/rubber mount isolators for blower shall be considered. (c) 18500 CFM,70 mm ESP

1

988594

988594

... More
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc.

5

6462

32310

... More
Supplying and fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers.

5

8678

43390

... More
CONTROL PANELS FOR FANS,AIRWASHER and SCRUBBER Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted control panels, including anchoring into the wall, wiring terminating into MCCB and copper earthing, in each panel shall be provided by the electrical contractor. All outgoing shall be provided with Stop /Manual /Auto selector switch to facilitate operation through CILP. All starters shall be provided with potential free Contact for Connections. All wiring and copper earthing of motors from the panel shall be included. The panel shall include the following components and accessories. MCCB as per the ratings given below, suitable for motor duty and able to withstand fault level of 20 KA. DOL / SD starter as per HP gratings given. c. Terminal block for power distribution as required. d. Contractor, over load relay with built in single phasing protection. e. Phase indicating lights and indicating light for `ON’ status. f. 144 mm x 144 mm voltmeter and digital ammeter. g. Time delay relay for delayed automatic restart of motor. h. Wiring for micro switch for stopping the fan when fire damper closes (in required by application). i. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each panel to facilitate override of the automatic operation. j. All starters shall be provided with suitable potential free contract for connections to the Building Automation System. k. All starters for Air washer and Scrubber pumps (as required) with cabling,wiring and earthing shall be included in their control panel for fans. l. 220 / 24 V Transformer (as required by application) The number of control panels shall be as follows. (01) 25 amps MCCB, 5HP with DOL Starter

4

3206

12824

... More
CONTROL PANELS FOR FANS,AIRWASHER and SCRUBBER Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted control panels, including anchoring into the wall, wiring terminating into MCCB and copper earthing, in each panel shall be provided by the electrical contractor. All outgoing shall be provided with Stop /Manual /Auto selector switch to facilitate operation through CILP. All starters shall be provided with potential free Contact for Connections. All wiring and copper earthing of motors from the panel shall be included. The panel shall include the following components and accessories. MCCB as per the ratings given below, suitable for motor duty and able to withstand fault level of 20 KA. DOL / SD starter as per HP gratings given. c. Terminal block for power distribution as required. d. Contractor, over load relay with built in single phasing protection. e. Phase indicating lights and indicating light for `ON’ status. f. 144 mm x 144 mm voltmeter and digital ammeter. g. Time delay relay for delayed automatic restart of motor. h. Wiring for micro switch for stopping the fan when fire damper closes (in required by application). i. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each panel to facilitate override of the automatic operation. j. All starters shall be provided with suitable potential free contract for connections to the Building Automation System. k. All starters for Air washer and Scrubber pumps (as required) with cabling,wiring and earthing shall be included in their control panel for fans. l. 220 / 24 V Transformer (as required by application) The number of control panels shall be as follows. (02) 32 amps MCCB, 10HP with Star-Delta Starter

3

16031

48093

... More
CONTROL PANELS FOR FANS,AIRWASHER and SCRUBBER Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted control panels, including anchoring into the wall, wiring terminating into MCCB and copper earthing, in each panel shall be provided by the electrical contractor. All outgoing shall be provided with Stop /Manual /Auto selector switch to facilitate operation through CILP. All starters shall be provided with potential free Contact for Connections. All wiring and copper earthing of motors from the panel shall be included. The panel shall include the following components and accessories. MCCB as per the ratings given below, suitable for motor duty and able to withstand fault level of 20 KA. DOL / SD starter as per HP gratings given. c. Terminal block for power distribution as required. d. Contractor, over load relay with built in single phasing protection. e. Phase indicating lights and indicating light for `ON’ status. f. 144 mm x 144 mm voltmeter and digital ammeter. g. Time delay relay for delayed automatic restart of motor. h. Wiring for micro switch for stopping the fan when fire damper closes (in required by application). i. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each panel to facilitate override of the automatic operation. j. All starters shall be provided with suitable potential free contract for connections to the Building Automation System. k. All starters for Air washer and Scrubber pumps (as required) with cabling,wiring and earthing shall be included in their control panel for fans. l. 220 / 24 V Transformer (as required by application) The number of control panels shall be as follows. (03) 40 amps MCCB, 7.5HP with DOL Starter

1

9191

9191

... More
CONTROL PANELS FOR FANS,AIRWASHER and SCRUBBER Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted control panels, including anchoring into the wall, wiring terminating into MCCB and copper earthing, in each panel shall be provided by the electrical contractor. All outgoing shall be provided with Stop /Manual /Auto selector switch to facilitate operation through CILP. All starters shall be provided with potential free Contact for Connections. All wiring and copper earthing of motors from the panel shall be included. The panel shall include the following components and accessories. MCCB as per the ratings given below, suitable for motor duty and able to withstand fault level of 20 KA. DOL / SD starter as per HP gratings given. c. Terminal block for power distribution as required. d. Contractor, over load relay with built in single phasing protection. e. Phase indicating lights and indicating light for `ON’ status. f. 144 mm x 144 mm voltmeter and digital ammeter. g. Time delay relay for delayed automatic restart of motor. h. Wiring for micro switch for stopping the fan when fire damper closes (in required by application). i. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each panel to facilitate override of the automatic operation. j. All starters shall be provided with suitable potential free contract for connections to the Building Automation System. k. All starters for Air washer and Scrubber pumps (as required) with cabling,wiring and earthing shall be included in their control panel for fans. l. 220 / 24 V Transformer (as required by application) The number of control panels shall be as follows. (04) 40 amps MCCB, 12.5HP with Star-Delta Starter

1

19238

19238

... More
CONTROL PANELS FOR FANS,AIRWASHER and SCRUBBER Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted control panels, including anchoring into the wall, wiring terminating into MCCB and copper earthing, in each panel shall be provided by the electrical contractor. All outgoing shall be provided with Stop /Manual /Auto selector switch to facilitate operation through CILP. All starters shall be provided with potential free Contact for Connections. All wiring and copper earthing of motors from the panel shall be included. The panel shall include the following components and accessories. MCCB as per the ratings given below, suitable for motor duty and able to withstand fault level of 20 KA. DOL / SD starter as per HP gratings given. c. Terminal block for power distribution as required. d. Contractor, over load relay with built in single phasing protection. e. Phase indicating lights and indicating light for `ON’ status. f. 144 mm x 144 mm voltmeter and digital ammeter. g. Time delay relay for delayed automatic restart of motor. h. Wiring for micro switch for stopping the fan when fire damper closes (in required by application). i. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each panel to facilitate override of the automatic operation. j. All starters shall be provided with suitable potential free contract for connections to the Building Automation System. k. All starters for Air washer and Scrubber pumps (as required) with cabling,wiring and earthing shall be included in their control panel for fans. l. 220 / 24 V Transformer (as required by application) The number of control panels shall be as follows. (05) 40 amps MCCB, 15HP with Star-Delta Starter

1

22444

22444

... More
CONTROL PANELS FOR FANS,AIRWASHER and SCRUBBER Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted control panels, including anchoring into the wall, wiring terminating into MCCB and copper earthing, in each panel shall be provided by the electrical contractor. All outgoing shall be provided with Stop /Manual /Auto selector switch to facilitate operation through CILP. All starters shall be provided with potential free Contact for Connections. All wiring and copper earthing of motors from the panel shall be included. The panel shall include the following components and accessories. MCCB as per the ratings given below, suitable for motor duty and able to withstand fault level of 20 KA. DOL / SD starter as per HP gratings given. c. Terminal block for power distribution as required. d. Contractor, over load relay with built in single phasing protection. e. Phase indicating lights and indicating light for `ON’ status. f. 144 mm x 144 mm voltmeter and digital ammeter. g. Time delay relay for delayed automatic restart of motor. h. Wiring for micro switch for stopping the fan when fire damper closes (in required by application). i. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each panel to facilitate override of the automatic operation. j. All starters shall be provided with suitable potential free contract for connections to the Building Automation System. k. All starters for Air washer and Scrubber pumps (as required) with cabling,wiring and earthing shall be included in their control panel for fans. l. 220 / 24 V Transformer (as required by application) The number of control panels shall be as follows. (06) 63 amps MCCB, 20HP with Star-Delta Starter

1

26719

26719

... More
Supply Installation Testing and Commissioning Small Form Factor Pluggable 1 Gigabit single Mode Fiber Module with and LC connector. Typical reach of 10 Km on 9/125 m SMF.

40

5715

228600

... More
Supply, erection, testing and commissioning of LIFT-ERD/online UPS system For 20 Passenger Lift with following details : Lift motor load:10.8Kw, Rated current: 31.7A, 3Phase in 3Phase Out, With inbuilt isolation transformer, Micro controller based IGBT technology, Advanced technology: DSP based controller for power and monitoring, True online dual conversion design. Battery Backup for 15-20 mins, A. 30nos.*12V/42AH 30Kva. Heavy duty angle iron racks plus UNINVYN fire retardant copper battery interlinks.

1

624375

624375

... More
Supply, Erection, Testing and Commissioning of Solar Hot Water System with Followings Details :System Out Pumt Temperature : 60degree C (during clear sunny days), System type : Thermosyphone with Heat Exchanger. System : Non-Pressurized, Application : Wathing/ Cooking, Type of Solar Collectors : Copper tube Flat Plate Collectors as per BIS and ISI Marked with Following Specifications: Size of Solar Collectors : 2030 x1030x 100mm ±10mm, Absorber area : 2sq M, Number of Collectors: To suit system requirement. Type: Cu-Cu, Absorber coating : Selective (Absorber Aluminium), Absorvity :?0.95, Emissivity:?0.2, Frame Material : 16SWG extruded Aluminium, Glazing : Toughened Glass 3.2mm, Glass beeding : EPDM, Finish : Painted by approved shade, Hardware : SS 304, Insulation: Rockwool 40mm at Bottom and 25mm on Sides of collector. Collector Stand 35*35*3mm MS Angle, Hot Water Tank: Cylindrical -vertical/Horizontal, Stainless Steel 304 grade with 100mm thick Rockwool Insulation including 22 SWG aluminum cladding. The entire system should be complete with internal piping in SS 302 with 50mm Rockwool insulation of density 48kg/m³ with 26SWG AL cladding, necessary isolation valves , Y type CI strainer, hardware, temperature gauge of range 0-120°C,Water Meter , MS Angle iron Structure of min thickness 3mm duly painted etc. as required to complete system. The entire system should be approved by BIS. System Capacity : 6500 Litrs. (1625 Litrs SWHS with 16 collectors X 4 Nos)

6500

342

2223000

... More
Supply, Installation, Testing and Commissioning of UL/FM Certified Extinguishing agent filled in PESO Approved Filling Station: 4 Kg FK-5-1-12 Clean agent filled in PESO approved stored pressure type seamless steel cylinder as per IS 7285 (life 15years) with automatic type DLP valve assembly PI marked, TPED (Transportable Pressure Equipment Directive) approved, Used Standards for type approvals ISO 17871:2015 in conjunction with EN ISO 10297:2014 EN ISO 14246: 2017-12, Push in connector, End of line adapter, UL listed Pr. Switch, end of line plug, T connector, Safety Burst Disc at 28 Bar and Mounting Bracket. Stored Pressure type fitted with Pressure gauge, UV Resistance, Operating Pressure 15 bar, Hydraulic Pressure Tested to 250 bar, Burst Pressure at 350 bar, Red Powder coated. Certified by National Test House, Dept of Consumer Affairs, Govt. of India. system design as per NFPA 2001 and Installed as per LPS 1666.

1

124231

124231

... More
Supply, Installation, Testing and Commissioning of UL/FM Certified Extinguishing agent filled in PESO Approved Filling Station: 2 Kg FK-5-1-12 Clean agent filled in PESO approved stored pressure type seamless steel cylinder as per IS 7285 (life 15years) with automatic type DLP valve assembly PI marked, TPED (Transportable Pressure Equipment Directive) approved, Used Standards for type approvals ISO 17871:2015 in conjunction with EN ISO 10297:2014 EN ISO 14246: 2017-12, Push in connector, End of line adapter, UL listed Pr. Switch, end of line plug, T connector, Safety Burst Disc at 28 Bar and Mounting Bracket. Stored Pressure type fitted with Pressure gauge, UV Resistance, Operating Pressure 15 bar, Hydraulic Pressure Tested to 250 bar, Burst Pressure at 350 bar, Red Powder coated. Certified by National Test House, Dept of Consumer Affairs, Govt. of India. system design as per NFPA 2001 and Installed as per LPS 1666

2

72785

145570

... More
Supply, Installation, Testing and Commissioning of Master Control Unit inbuilt A/v alarm Control Panel along with sounder cum strobe of 24VDC operated red colour MS housing , 2 NO/NC potential free relay contact for Main Fire Alarm. Modbus for BMS Integration. Gas discharge led indicator, battery led indicator, system status Led indicator, AC power ON Led indicator.

3

29152

87456

... More
Supply, Installation, Testing and Commissioning of UL Certified Linear pneumatic Heat Detection Tube (ID-6mm and OD-8mm) for automatic fire detection and suppression system made by special modified polyimide (PA), colour red RAL300, burst temperature 1310C, inner diameter 6mm, outer diameter 8mm. Pressurized with dry nitrogen at 15 bar pressure with all necessary fittings and supports. Certified by National Test House, Dept of Consumer Affairs, Govt. of India.

120

3581

429720



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.