Haryana Police Housing Corporation Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Haryana Police Housing Corporation - HPHC Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date9 Jan 2025
Closing Date16 Jan 2025
Tender Amount₹ 24,08,644 
Notes
Download

Costs

  • EMD

    ₹ 24,000
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 1,180

Summary

Supply And Installation Of New Tubewell In Cid Commando Training Centre, Village-chowki, Panchkula

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
HSR 11.8 :- CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix : 1. 1:4 (1 cement: 4 coarse sand)

21.43

114

2443.02

... More
HSR 11.9 :- CEMENT PLASTER (IN COARSE SAND) 15 mm cement plaster on rough side of single or half brick wall of mix: 2. 1:6 (1 cement: 6 coarse sand)

19.63

128

2512.64

... More
HSR 11.60 :- INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

41.06

59

2422.54

... More
HSR 11.95 :- EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

41.05

88

3612.4

... More
HSR 33.15 :- TUBEWELLS Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

65.4

1166

76256.4

... More
HSR 33.16:- TUBEWELLS Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 3. 200 mm dia

1

244

244

... More
HSR 33.17 :- TUBEWELLS Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts and nuts of required size complete. 3. 200 mm clamp

1

1358

1358

... More
HSR 33.18 :- TUBEWELLS Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 3. 200 mm dia

1

259

259

... More
HSR 33.19:- TUBEWELLS Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by `V` notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire and labour charges of air compressor, tools and accessories etc., all as per requirement and direction of Engineer-in-charge.

24

1030

24720

... More
HSR 7.21 :- B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand)

4.73

4128

19525.44

... More
HSR 22.98 :- BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 2. 20 mm nominal bore

30

384

11520

... More
HSR 22.98:- BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore.

10

485

4850

... More
HSR 22.156 :- CI/DUCTILE IRON PIPES AND SPECIALS Labour for cutting C.I. pipe with steel saw. 2. 100 mm diameter C.I. pipe

20

54

1080

... More
HSR 22.157:- CI/DUCTILE IRON PIPES AND SPECIALS Providing and laying SandS C.I. Standard specials such as tees, bends, collars tapers and caps etc, suitable for flanged jointing as per IS : 1538 : 1. Up to 300 mm dia

10

5000

50000

... More
HSR 22.162:- C.I. SLUICE VALVES/ FIRE HYDRANTS and FIXTURES Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 1.1. 100 mm diameter Class I

4

5044

20176

... More
HSR 22.179:- MASONRY CHAMBERS Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 2.1. Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : With common burnt clay non-modular bricks of class designation 7.5

3

4370

13110

... More
HSR 22.180:- MASONRY CHAMBERS Extra for depth beyond 45 cm of brick masonry chamber : 2.1. For 500x700 mm size With common burnt clay non-modular bricks of class designation 7.5

3

3101

9303

... More
HSR 22.185:- AIR VALVE and WATER METER (BULK TYPE) Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 3. 100 mm dia

1

6901

6901

... More
HSR 6.1:- A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)

10.6

3975

42135

... More
HSR 6.1:- A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

10.95

2442

26739.9

... More
HSR 20.11:- C FIXING OF C.I. VALVES HYDRANTS Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge 2. 100 mm i/d

1

3426

3426

... More
HSR 20.23 :- D LAYING OF G.I./ P.V.C./W.I. PIPES AND SPECIALS Extra for fixing and jointing union couplings in G.I. and W.I. pipelines. 2. 20 mm internal diameter

10

9

90

... More
HSR 20.23 :- D LAYING OF G.I./ P.V.C./W.I. PIPES AND SPECIALS Extra for fixing and jointing union couplings in G.I. and W.I. pipelines. 4. 32 mm internal diameter

10

13

130

... More
HSR 20.24:- E DRILLING AND TAPPING OF C.I. PIPES Drilling and tapping cast iron pipe lines of all diameters and screwing in ferrule and connections 3. Ferrule size 20 mm

30

671

20130

... More
HSR 20.24:-E DRILLING AND TAPPING OF C.I. PIPES Drilling and tapping cast iron pipe lines of all diameters and screwing in ferrule and connections 5. Ferrule size 32 mm

20

756

15120

... More
HSR 20.54:-L FILTER MEDIA Providing GI pipes class B marked with IS: 1239 in 3.05 m length, their threading and welding with flanges (Heavy Duty) on both sides, jointing with nuts and bolts ( ‘W’ make), rubber gaskets , lowering into Tube wells and testing including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in- Charge. 3. 80 mm i/d

44

1648

72512

... More
HSR 20.96:-INSTALLATION OF SHALLOW/MEDIUM/DEEP TUBEWELLS AS PER IS 2800:1991 Drilling of 609.60mm dia bore by hydraulic rotary drilling (reverse circulation method) percussion rig according to ISI specification No. 2800-1991 (Part-I) as amended up to date and modified to extent of the specification attached with this schedule of items of work in all kinds of soils and boulders up to 125 mm dia except rocky strata including the cost of all consumable stores, fuel, oil, soil stabilizing material and transportation of rig and other accessories to the site of proposed bore and back including cost of lowering of all size of casing pipe while boring and extracting the same against earth friction etc. complete to the satisfaction of the Engineer-in-charge. 1. Drilling from 0 metre but up to 200 metre BGL

181

870

157470

... More
HSR 20.101:-INSTALLATION OF SHALLOW/MEDIUM/DEEP TUBEWELLS AS PER IS 2800:1991 Supplying as per IS 226 as amended up to date deodar wooden box made of 20mm thick wood size 60 cm x 75 cm x 30 cm with lid and locking arrangement etc for preserving the strata samples received from the bore as and when desired by the Engineer-in-charge.

1

580

580

... More
HSR 20.104:- INSTALLATION OF SHALLOW/MEDIUM/DEEP TUBEWELLS AS PER IS 2800:1991 Electric logging of tube well.

1

13914

13914

... More
HSR 20.105:- INSTALLATION OF SHALLOW/MEDIUM/DEEP TUBEWELLS AS PER IS 2800:1991 Providing and fixing centralizer guides (centralizer) fitted to the well assembly except the housing pipe, at bottom and at a spacing of 12 m centre to centre, to keep the assembly in centre of the bore hole as per approved design and specifications with MS threaded socket, confirming to IS : 226 amended up to date. Electric Resistance welded (ERW) M.S. Pipes / ERW Cage type Vee wire wound screen / Stainless steel screen / galvanized screens duly ISI Marked

20

116

2320

... More
HSR 20.106:- INSTALLATION OF SHALLOW/MEDIUM/DEEP TUBEWELLS AS PER IS 2800:1991 Supply, testing and lowering (ERW) electric resistance welded M.S. pipes with MS threaded socket as per IS 4270 as amended up to date, duly ISI marked for housing pipe in 4 to 7 metres random length into bore well with 88.90mm of threaded ends (8 threads to an inch or 25.40 mm) manufactured out of 8mm thick MS plates with required numbers of MS socket 177.8mm with inside thread to match the pipe threads and made out of MS plate in to borehole in vertical position including cost of all tools and plants, complete in all respects to the satisfaction of Engineer-in-charge, including cost of all cutting, threading of pipe, welding, where required and all sockets. The pipe shall be painted with anti corrosive paint and covered tightly with polythene of following sizes: 1. 200x6.4mm

158

2374

375092

... More
HSR 20.107:- INSTALLATION OF SHALLOW/MEDIUM/DEEP TUBEWELLS AS PER IS 2800:1991 Supply, testing and lowering of ISI marked all welded stainless steel screen (SS304) cage Type V-Wire Wound Screens in bore wells conforming to IS:8110 and compositions of material as per IS:1012, outer dia 221mm equivalent thickness required as per code, tensile load 14000 kg minimum and ring thickness as per IS code of following sizes:- 1.1. Stainless Steel Screens 200x8.0x0.50mm

24.66

7868

194024.88

... More
HSR 20.114:- INSTALLATION OF SHALLOW/MEDIUM/DEEP TUBEWELLS AS PER IS 2800:1991 Supplying erection, testing of fully automatic electric control panel board for T/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of 0 to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in all respect. 3. 20 HP Motor

1

23190

23190

... More
HSR 20.124:- INSTALLATION OF SHALLOW/MEDIUM/DEEP TUBEWELLS AS PER IS 2800:1991 Supplying, erection, testing and commissioning of submersible pumping sets as per BIS SPECIFICATION No. 8034-1989 (as amended upto date for pumps) and IS 9283-1979 (as amended upto date for motor) the pump motor sets should be capable of pumping clear fresh cold water having characteristics as specified in Clause-4 of IS 8034-1989 and Clause 4.1 of IS 9283-1979. 92. LPM 400 Head 135 BHP 20.00 Say Round BHP 20.00

2

74915

149830

... More
HSR 4.16:- Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia.

760

64

48640

... More
HSR 9.22:- SHEET ROOFING Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1. 1.00 mm thick with zinc coating not less than 275 gm/m²

12.25

1157

14173.25

... More
HSR 13.28:- SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

900

75

67500

... More
HSR 13.30:- SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 1. Hot finished welded type tubes

150

105

15750

... More
HSR 22.87:- C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 2. 20 mm nominal outer dia Pipes

175

146

25550

... More
HSR 22.87:- C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 4. 32 mm nominal outer dia Pipes

150

272

40800

... More
HSR 22.160:- CI/DUCTILE IRON PIPES AND SPECIALS Providing and laying SandS Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 : 1. 100 mm dia Ductile Iron Class K-7 pipes

760

956

726560

... More
HSR 23.3:- COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)

30

88

2640

... More
HSR 23.3- COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm)

5

144

720

... More
HSR 23.4:- COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A

6

520

3120

... More
HSR 23.4:- COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.1. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A

1

999

999

... More
HSR 24.1:- EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.

2

2721

5442

... More
HSR 24.1:- EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.

2

652

1304

... More
HSR 24.1- EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.

20

189

3780

... More
HSR 24.2:-LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core

4

77

308

... More
HSR 24.2:-LT CABLE 8.5. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in- charge of the work. 25 sqmm

16

10

160

... More
HSR 24.5:-MISCELLANEOUS ITEMS 1.5. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. Submersible Copper Cable 3 Core 10 sqmm

280

183

51240

... More
HSR 24.5:-MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia

80

124

9920

... More
HSR 23.8-FITTING AND ACCESSORIES 1.12. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size.

2

46

92

... More
HSR 23.8:-FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch

1

41

41

... More
HSR 23.8:-FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket

1

82

82

... More
HSR 23.8:-FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate

1

18

18

... More
HSR 23.20:-Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required

3

67

201

... More
HSR 23.22:MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA

1

6130

6130

... More
HSR 23.22: MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP

1

1815

1815

... More
HSR 23.22:-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.1. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 4 way ( 2 incoming and 2 outgoing)

1

1172

1172

... More
HSR 23.22:MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole

2

145

290

... More
HSR 23.22:MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE

1

426

426

... More
HSR 24.13:-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.)

85.7

217

18596.9

... More
Supply and erection of wall fan 16`` Sweep (400mm) oscillating type light duty complete with built-in regulator , blade, jali complete.

1

1916

1916

... More
Supply of surface mounting LED batten fitting 1 x 18 /20 watt, (4 feet long), made of high grade polycarbonate body provided for efficient heat dissipation and Integrated electronic driver suitable for single phase A.C. 230 Volts, 50 Hz supply, complete in all respect.

3

191

573



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.