Haryana Police Housing Corporation Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Haryana Police Housing Corporation - HPHC Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Dec 2024
Closing Soon30 Dec 2024
Tender Amount₹ 49,04,843 
Notes
Download

Costs

  • EMD

    ₹ 98,000
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 1,180

Summary

Annual Repair (camc ) Of Estate Electrical Services Including Dg Set Acp Tower ,dcp Tower, Nit Police Lines ,police Lines Faridabad And Greater Faridabad

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA [Through Rate]

10

10809

108090

... More
[23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA [Through Rate]

12

4635

55620

... More
[23.22.1.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.4. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA [Through Rate]

6

5249

31494

... More
[23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA [Through Rate]

10

8577

85770

... More
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate]

30

6130

183900

... More
[23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate]

5

1815

9075

... More
[23.22.2.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.2. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FP [Through Rate]

2

4032

8064

... More
[23.22.3.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.2. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. S.P.N. or DP enclosure suitable for DP MCB [Through Rate]

3

356

1068

... More
[23.22.3.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.3. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. TPN enclosure suitable for TP , TPN or FP MCB [Through Rate]

5

414

2070

... More
[23.22.4.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.1. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 4 way ( 2 incoming and 2 outgoing) [Through Rate]

6

1172

7032

... More
[23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) [Through Rate]

3

1406

4218

... More
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]

150

145

21750

... More
[23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole [Through Rate]

100

677

67700

... More
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate]

20

1291

25820

... More
[23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. [Through Rate]

8

76

608

... More
[23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. [Through Rate]

24

93

2232

... More
[23.26.3]SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame. [Through Rate]

8

262

2096

... More
[23.26.4]SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia). [Through Rate]

7

2739

19173

... More
[23.3.6.4]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate]

70

172

12040

... More
[23.3.6.5]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate]

50

346

17300

... More
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]

300

32

9600

... More
[23.7.6.3]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia. [Through Rate]

300

45

13500

... More
[23.7.6.4]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. [Through Rate]

30

57

1710

... More
[23.8.5]FITTING AND ACCESSORIES 5. Supply and erection 5-30 A single phase A.C. energy metre , LCD display and optical port , with rag bolts on wall/existing pedestal including the cost of rag bolts required to complete the job in all respect with necessary connections and bonding to earth. [Through Rate]

20

1715

34300

... More
[23.8.8]FITTING AND ACCESSORIES 8. Supply and erection 10-60 A Three phase A.C. energy metre , LCD display and optical port , with rag bolts on wall/existing pedestal including the cost of rag bolts required to complete the job in all respect with necessary connections and bonding to earth. [Through Rate]

6

1970

11820

... More
[23.8.9]FITTING AND ACCESSORIES 9. Supply and erection direct reading LCD Display Digital Ammetre/Voltmetre ( without CT or PT ) on wall/existing penal complete in all respect with necessary connections [Through Rate]

7

994

6958

... More
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]

12

2721

32652

... More
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]

100

730

73000

... More
[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate]

200

21

4200

... More
[24.1.14]EARTHING AND LIGHTENING ARRESTOR 14. Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size. [Through Rate]

84

62

5208

... More
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]

12

652

7824

... More
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate]

4

3368

13472

... More
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate]

4

8275

33100

... More
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate]

8

801

6408

... More
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]

200

96

19200

... More
[24.13.100]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 100. 400 Sq mm 3.5 core (Arm.) [Through Rate]

100

2006

200600

... More
[24.13.19]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 19. 16 Sq mm 2 core (UnArm.) [Through Rate]

300

93

27900

... More
[24.13.20]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 20. 16 Sq mm 2core (Arm.) [Through Rate]

300

127

38100

... More
[24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate]

600

180

108000

... More
[24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) [Through Rate]

300

217

65100

... More
[24.13.40]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 40. 35 Sq mm 4 core (Arm.) [Through Rate]

500

282

141000

... More
[24.13.54]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 54. 70 Sq mm 3.5 core (Arm.) [Through Rate]

800

453

362400

... More
[24.13.62]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 62. 95 Sq mm 3.5 core (Arm.) [Through Rate]

180

561

100980

... More
[24.13.82]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 82. 185 Sq mm 3.5 core (Arm.) [Through Rate]

200

1011

202200

... More
[24.16.2]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 2. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 50 Sq mm 3 core [Through Rate]

50

739

36950

... More
[24.16.4]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 4. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 95 Sq mm 3 core [Through Rate]

50

991

49550

... More
[24.16.7]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 7. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 185 Sq mm 3 core [Through Rate]

100

1531

153100

... More
[24.2.7.2]LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core [Through Rate]

20

45

900

... More
[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core [Through Rate]

20

77

1540

... More
[24.2.7.4]LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core [Through Rate]

25

104

2600

... More
[24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm [Through Rate]

161

8

1288

... More
[24.2.8.6]LT CABLE 8.6. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 35 sqmm [Through Rate]

50

11

550

... More
[24.2.8.7]LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm [Through Rate]

25

15

375

... More
[24.2.8.8]LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm [Through Rate]

81

20

1620

... More
[24.2.9.4]LT CABLE 9.4. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 10 to 16 sqmm Cable 3 to 4 Core [Through Rate]

15

1299

19485

... More
[24.2.9.5]LT CABLE 9.5. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 25 sqmm to 50 sqmm Cable 3 to 4 Core [Through Rate]

10

2395

23950

... More
[24.2.9.6]LT CABLE 9.6. Supply and erection of straight through joint (cable jointing kit) 1.1 KV grade complete with required quantity of resin, hardener, plastic mould G.P. Putty, adhesive, earth continuity, connections and fixing the same in position complete with joint etc. - Straight through Joint. For 70 sqmm to 150 sqmm Cable 3 to 4 Core [Through Rate]

15

3662

54930

... More
[24.3.1.2]HT CABLE 1.2. Laying and erection of XLPE (E)II kv HT aluminium conductor armoured cable 1 metre below ground level with sand & bricks with all labour and material including digging and refilling of trench as required above 120 and up to 300 sqmm 3 core XLPE Cable [Through Rate]

100

183

18300

... More
[24.3.3.2]HT CABLE 3.2. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :150 to 185 sqmm [Through Rate]

10

8736

87360

... More
[24.3.3.3]HT CABLE 3.3. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 to 400 sqmm [Through Rate]

7

10280

71960

... More
[24.3.4.2]HT CABLE 4.2. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 150 to 185 sqmm [Through Rate]

5

13199

65995

... More
[24.3.4.3]HT CABLE 4.3. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240 to 400 sqmm [Through Rate]

6

17536

105216

... More
[24.4.7.2]STREET LIGHT 7.2. Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia [Through Rate]

100

385

38500

... More
[24.5.2.2]MISCELLANEOUS ITEMS 2.2. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 50/40 mm outer dia/ inner dia [Through Rate]

700

109

76300

... More
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]

1500

124

186000

... More
[24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate]

1200

161

193200

... More
Labour Charges for detection of fault of L.T. underground cables 1.1 KV Highpots testing of various sizes with necessary equipment/ machine at the site of work, complete in all respect including transportation charges, site visit charges and testing charges etc.

4

9000

36000

... More
Labour Charges for detection of fault of HT underground cables 11 KV Highpots testing of various sizes with necessary equipment/ machine at the site of work, complete in all respect including transportation charges, site visit charges and testing charges etc.

3

13500

40500

... More
Servicing and Testing of 62.5 KVA D.G Set with Cleaning and lubrication of all moving parts including Premium Oil , Filter Oil, Inhibitor Corrosion, Seperator Fuel Water, Element Air Filter primary and secondary, and complete with handling and services charges and all other petty material to Complete the job in all respect with all labour upto entire satisfaction of EIC of the work.

3

21205

63615

... More
Servicing and Testing of 125 KVA D.G Set with Cleaning and lubrication of all moving parts including Premium Oil , Filter Oil, Inhibitor Corrosion, Seperator Fuel Water, Element Air Filter primary and secondary, and complete with handling and services charges and all other petty material to Complete the job in all respect with all labour upto entire satisfaction of EIC of the work.

1

25507

25507

... More
Supply and erection of automatic three phase street light controller with time switch operation ON and OFF, setting upto 24 hours, complete with timelite 65 amp. 3 pole 230 V analog time switch contactor and MS power coated enclosure of suitable size. The work will be complete in all respect including making necessary connection, earthing nuts and bolts and other petty material to complete the job. /[3Q]

2

17100

34200

... More
S/E of LED Flood Light 200 watt Outdoor Commercial LED lumaire made in pressure die cast and heat shrink aluminium extrusion with high power LEDs, Minimum working hours 50,000 Hours, Minimum output 110 lumens/watt , THD (10% IP-66, Surge Protection and making neccessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work.

20

8102

162040

... More
S/E of Street Light 70 watt LED Outdoor Commercial LED luminaire made in pressure die cast and heat shrink aluminium extrusion with high power LEDs, Minnimum working hours 50,000 Hours, Minimum output 110 lumens/watt , THD (10% IP-66, Surge Protection and making neccessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work.

80

3632

290560

... More
Supply and Filling of Transformer oil complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work

350

136

47600

... More
Dehydration and Filtration of Transformer oil For 200/250 KVA Transformer by Machine complete with all Labour to complete the job in all respect.

4

5113

20452

... More
Labour charges for 1 No. Technician for day to day maintenance of miscellaneous and repair work including detection of electrical fault, dismantling and erection of any electrical material.

180

471

84780

... More
Labour charges for 1 No. Skilled Electrician for day to day maintenance of miscellaneous and repair work of estate electrical 1.1 Kv, 11 kv, HT/LT Line including detection of electrical fault, dismantling and erection of any electrical material.

180

568

102240

... More
S/E of Flood Light 50 watt LED luminaire Outdoor Commercial LED Luminaires made in pressure die cast and heat shrink aluminium extrusion with high power LEDs, Minimum working hours 50,000 Hours, Minimum output 110 lumens/watt , THD (10% IP-66, Surge Protection and making necessary connection etc, suitable for operation on 230 volts A.C supply, complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work.

20

3242

64840

... More
S/E of Vacuum interrupter for 11KV VCB Complete in all respect as entire satisfaction of engineer in charge (Crompton/Areva - Make)

1

20453

20453

... More
S/E of Busbar support insulator for 11KV VCB Complete in all respect as entire satisfaction of engineer in charge.

2

795

1590

... More
Servicing and Testing of 11 KV HT VCB Complete with Cleaning and lubrication of complete mechanism, Cleaning and lubrication of all moving and fix contacts, Tightening of all joints, nut bolts, etc., Checking of over current and earth fault relay and its circuits, Checking of CT,s, and other control wiring, IR Value test of CT, bus bar, insulator and complete VCB, Testing of CT and Control circuit by relay testing kit, Primary and Secondary current injection test of CT circuit, Testing and calibration of O/C and E/F Relay, Programming of relay according to transformer, Setting of relay parameters to Complete the job in all respect with all labour upto entire satisfaction of EIC of the work.

2

6818

13636

... More
S/E of PT 11KV/110V AC for 11KV VCB Complete in all respect as entire satisfaction of engineer in charge. (Crompton/Areva/Savio-Make)

1

39769

39769

... More
S/E of PT Fuse 11KV/3.15Amp for 11KV VCB Complete in all respect as entire satisfaction of engineer in charge. (GE/Bushman-Make)

3

1704

5112

... More
S/E of PT Spout Insulator for 11KV VCB Complete in all respect as entire satisfaction of engineer in charge.

6

2045

12270

... More
S/E of CT for 11 KV VCB Complete Set in all respect as entire satisfaction of engineer in charge. (CG/Savio-Make)

1

24998

24998

... More
S/E of Power Pack 230V AC/ 24V DC for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge. (CG/Savio-Make)

1

10226

10226

... More
S/E of Indication Lamp for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge. (LandT, Siemens-Make)

6

341

2046

... More
S/E of TNC Switch 1NO plus 1NC for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge. (Selzor/LandT-Make)

2

1704

3408

... More
S/E of Contact Insulator for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge.

3

2045

6135

... More
S/E of VCB Spring charging motor for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge. (Delco/Agni/GE-Make)

1

10226

10226

... More
S/E of Space Heater 230AC for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge. (Hot star-make)

6

568

3408

... More
S/E of VCB Rack-IN, Rack-Out Gear for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge. (CG/Schnieder-make)

1

5681

5681

... More
S/E of Digital Volt/Amp Meter for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge.

2

2273

4546

... More
S/E of VCB Charging Gear Big for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge.

1

6818

6818

... More
S/E of VCB Charging Gear Small for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge.

1

2727

2727

... More
S/E of Auxiliary Switch for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge. (Selzor/LandT-Make)

1

6818

6818

... More
S/E of Master trip relay for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge. (ABB, Easun, Crompton-Make)

1

3977

3977

... More
S/E of VCB Coil for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge. (Crompton/Areva-Make)

1

5681

5681

... More
S/E of Numerical O/C, E/F Relay for 11 KV VCB Complete in all respect as entire satisfaction of engineer in charge. (Crompton/Areva-Make)

1

20453

20453

... More
Dehydration and Filtration of Transformer oil for 500/400 KVA Transformer by Machine Complete with all labour to Complete the job in all respect.

5

6818

34090

... More
Servicing and testing of 630 KVA Compact Substation having HT RMU Comprising of 2 Nos. 630 Amp. Load Switches , 630 KVA Dry Type Transformer and LT Panel With 200 KVAR Capacitor Bank, Testing of RMU (CRM andamp: IR), Operation Test of RMU with Mechanism checking, Testing of Closing/Tripping Coil, Testing of Current Transformer, Testing of Num. Relay, Testing of Transformer (IR, Ratio andamp: Wdg. Resistance), Checking of ACB andamp: MCCB Operation Complete the job in all respect with all labour upto entire satisfaction of EIC of the work.

2

56813

113626

... More
Servicing and testing of 500 KVA Compact Substation having HT RMU Comprising of 2 Nos. 500 Amp. Load Switches , 500 KVA Dry Type Transformer and LT Panel With 200 KVAR Capacitor Bank, Testing of RMU (CRM andamp: IR), Operation Test of RMU with Mechanism checking, Testing of Closing/Tripping Coil, Testing of Current Transformer, Testing of Num. Relay, Testing of Transformer (IR, Ratio andamp: Wdg. Resistance), Checking of ACB andamp: MCCB Operation Complete the job in all respect with all labour upto entire satisfaction of EIC of the work.

2

45450

90900



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.