Gurugram University Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 3,77,000Document Cost
₹ 15,000Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HRY_366106_1Bid Award Id
ViewTender No
20245DDF832C 9C4D 4A3E 9AEB 34CC282766051857GGUTender Authority
Gurugram University ViewPurchaser Address
-Website
http://etenders.hry.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
The ODU shall have refrigerant cooled PCB Chamber for better operation at high ambient temperature
-
-
-
The system shall deliver at least 87% of mentioned nominal capacity at 43 Deg C ambient temperature.
-
-
-
The Fan static pressure of ODU shall be minimum 75 Pa to avoid hot air accumulation.
-
-
-
40 HP (20 HP + 20 HP ODU UNIT)
7
-
1145992.7
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Make- MITSUBISHI ELECTRIC / O GENERAL / DAIKIN/ Blue Star
-
-
-
2 TR or 2.5 HP (or above) 4 - way Cassette Unit Location:
12 Nos in Admin Block
20 Nos in Academic Block
35
-
66213.23
3 TR or 4.0 HP (or aboe) 4 - way Cassette Unit
47
-
73996.25
Supply & Fixing of Interconnecting copper refrigerant pipe work with thick duly insulated with Nitrile insulation between indoor and outdoor units as per specifications Approved Makes- Rajco/Mandev/Maxflow or as per directions of Engineer In-Charge
-
-
-
6.4 mm dia (1/4) 19mm Thickness with insulation 9 mtr lumpsum in Admin Block
21 mtr lumpsum in Academic Block
30
-
416.76
9.5 mm dia (3/8) (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
540
-
556.79
12.7 mm dia (1/2) (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation 28 mtr lumpsum in Admin Block
7 mtr lumpsum in Academic Block
35
-
698.82
15.86 mm dia (5/8) (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
700
-
985.54
19.1 mm dia (6/8) (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
108
-
1027.26
22.2 mm dia (OD) (7/8) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
30
-
1211
25.4 mm dia (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
65
-
1395.62
28.58 mm dia (11/8) (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
125
-
1666.07
31.8 mm dia (OD) (hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
25
-
1933.6
34.9 mm dia (13/8) (OD) (hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
25
-
2326.48
41.3 mm dia (15/8) (OD) (hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
160
-
2976.8
Supply & Installation of Refrigerant R-410A to top up the system as per directions of OEM.
295
-
980.33
Supply, installation, testing and commissionig of refrigerant Copper Y-joints Approved Makes- MITSUBISHI ELECTRIC / O GENERAL / DAIKIN/ Blue Star as per directions of Engineer In-Charge
130
-
2632.98
Supply, Installation, Testing and Commissioning of Master Remote Control panel including all necessary control wiring. Master Remote Control Panel shall be connected to all indoor/outdoor units and shall be of one touch screen type. Make- MITSUBISHI ELECTRIC / O GENERAL / DAIKIN or as per directions of Engineer In-Charge
-
-
-
Suitable for indoor units.
2
-
86482.49
CONTROL AND TRANSMISSION WIRING: Supply and Laying of 2 core x 1.5 sqmm PVC insulated copper conductor communication control cable in PVC Conduit. Approved Make : Havells/ Polycab/ RR Kabel/ Anchor/ KEI or as per directions of Engineer In-Charge
1200
-
97.06
POWER CABLE: Supply and Laying of 3 core x 2.5 sqmm PVC insulated copper conductor cable for indoor units. Approved Make : Havells/ Polycab/ RR Kabel/ Anchor/ KEI or as per directions of Engineer In-Charge
700
-
129.64
Supply and Laying 4.0 core x 25 Sq.mm Alluminium conductor armoured cable. Approved Make : Havells/ Polycab/ RR Kabel/ Anchor/ KEI or as per directions of Engineer In-Charge
250
-
250.96
Supply, installation, testing & commissioning of cubical type main MV panel board suitable for 3 Phase, 50 Hz and of 35 MVA rupturing capacity at 415 volts, fabricated from minimum 2mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with following mountings, interconnections etc. as required. (GA drawing of panel to be provided before fabrication). Panel shall be Floor mounted type with cable entry at the top and IP-65 Degree of protection. Panel shall be powder coated having colour shade RAL-7032. including the following switch gear and components: MAKE : UPS/ RR CONTROL/ TRICOLITE/Havells/L&T/SIEMENS or as approved by Engineer-in-charge
-
-
-
INCOMER: 400A FP MCCB 36kA TMR + Spreader Links - 01 nos
2
-
638200
OUTGOINGS: 125A FP MCCB 10KA (FOR VRF ODUs) - 7 Nos (as per site requirement)
-
-
-
10A TPN MCB 10KA(FOR VRF IDUs) - 82 Nos
-
-
-
Providing and fixing of MS Stand for Outdoor Units.
7
-
6757.46