Gurugram University Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Gurugram University Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Sep 2023
Closing Date3 Oct 2023
Tender Amount₹ 50,56,00,000 
Notes
Download

Costs

  • EMD

    ₹ 1,01,12,000
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing Panic Bar Double leaf panic exit devicesPEL 346 . (Required For Fire Staircase Location Doors Only). (Main Hall Doors) Becker F.S. Navair, Kutty Make with the prior approval of engineer-in-charge(N.S.ITEM)

32

-

17398

... More
Supply and fixing PEL905 Becker F.S. Make Panic Trim For Operation From The Other Side Of The Panic Bar. (Required For Fire Staircase Location Doors Only).Navair, Kutty Make with the prior approval of engineer-in-charge (N.S.ITEM)

7

-

5602

... More
Supply and fixing SS D Type Pull Handle of size 300mm mm Long of PHD2230.Navair, Kutty Make with the prior approval of engineer-in-charge (N.S.ITEM)

50

-

2854

... More
Supply and fixing Door closers of BLC-604 (Required For All Fire Doors Except Shaft Door). Make - Becker F.S or equivalent with the prior approval of engineer-in-charge. (N.S.ITEM)

64

-

2834

... More
Supply and fixing Stainless Steel 304 grade 300mm Long Tower Bolt of with necessary screws as required Make - Becker F.S or equivalent with the prior approval of engineer-in-charge. (N.S.ITEM)

63

-

1252

... More
Supply and fixing Anchor fastners of of maximum 120mm length. Make - HILTI, FISHER or equivalent with the prior approval of engineer-in-charge. (N.S.ITEM)

1160

-

79

... More
Supply and fixing IS-1212 S88 UL 1784-01 Smoke tested adhesive seal Make Smoke seal batwing type on all side of frame. Make - LORIENT/ Becker FS / PEMKO with the prior approval of engineer-in-charge. (N.S.ITEM)

232

-

174

... More
Supply and fixing 5 MM thick clear Non wire 2 Hr Fire Vision glass 300x300mm. Make - Saint gobain or Equivalent with the prior approval of engineer-in-charge. (N.S.ITEM)

63

-

4020

... More
Providing and Fixing SS ball bearing hinge (100x 75 x 3mm) - Isuzul/Godrej/Hettich or equivalent make as per prior approval of Engineer-in-Charge. (N.S.ITEM)

1160

-

382

... More
Providing and Fixing Tower bolt 12" Aluminium - Godrej/ Ebco/ Hafele make as per prior approval of Engineer-in-Charge. (N.S.ITEM)

237

-

474

... More
Providing and Fixing SS finish door stopper - Model Godrej/ Ebco/ Hafele make as per prior approval of Engineer-in-Charge. (N.S.ITEM)

237

-

198

... More
Providing and Fixing SS back stopper - Model Godrej/ Ebco/ Hafele or equivalent make as per prior approval of Engineer-in-Charge. (N.S.ITEM)

237

-

178

... More
Providing and Fixing Pull handle 240 mm - Model Godrej/ Ebco/ Hafele or equivalent make as per prior approval of Engineer-in-Charge. (N.S.ITEM)

474

-

1463

... More
Providing and Fixing Door Closer 60 kg Tto 90 kg of Ebco, Godrez make as per prior approval of Engineer-in-Charge.

275

-

2504

... More
Providing and Fixing Mortise lock and latch with both side handle and keyed cylinder. 5991 NEH-16, 200mm of Ebco, Godrez make as per prior approval of Engineer-in-Charge.

57

-

2570

... More
Providing and Fixing Patch fittings with 90 kg Floor spring of Ebco, Godrez make.

4

-

8106

... More
Providing and Fixing H Handle SS 304 , 750 mm hole to hole of Ebco, Godrez make.

8

-

3361

... More
Providing & Fixing ALDROP 16*200mm stainless steal complete in all respect of Godrej/ Ebco/ Hafele or equivalent make as per prior approval of Engineer-in-Charge. (N.S.ITEM)

156

-

1893

... More
Providing and fixing in position restroom/toilet cubicle system / having depth minimum 1500 mm and urinal partions as per manufacturer specs at all floor levels complete in all respects as per approved design/architectural drawings and as per the directions of Engineer-in-charge. The cubicle system shall comprise of the following:18 mm thick high pressure laminated board, laminate of any colour/shade as approved by the Engineer-in-charge on both sides of the board, manufactured as per EN 438-2&3, 2005. Board shall have density of minimum 1350 kg/cum and it shall be water resistant, anti-bacterial and impact resistant.SS 316 grade shoe box section at the bottom having dimensions and thickness as recommended by the approved vendor (but minimum 93 mm x 36 mm and minimum 0.8 mm thickness)SS 304 grade F-profile having dimensions and thickness as recommended by the approved vendor (but minimum 35 mm x 18 mm and minimum 0.6 mm thickness) / H-profile having dimensions and thickness as recommended by the vendor (but minimum 18 mm and minimum 0.6 mm thickness)SS 304 grade U-profile having dimensions and thickness as recommended by the approved vendor (but minimum 21 mm x 18 mm and minimum 0.6 mm thickness)SS 304 grade knob as per approved vendor's specifications or as approved by Engineer-in-charge SS 304 grade lock with a handle as per approved vendor's specifications or as approved by Engineer-in-chargeSS 304 grade auto reverse ball bearing hinges 3 No of size as recommended by the approved vendor but minimum 76 mm x 53 mm x 2.4 mmSS 304 grade coat hook as approved by the Engineer-in-chargeItem/rate includes all accessories etc required for fixing of the urinal partition even if it is not explicitly mentioned in the above description of the item. Nothing extra shall be payable on any account. Contractor shall quote rate accordingly.Note: Only exposed area of laminated board in sqm shall be measured for payment purpose)(Approved Make/Vendor : Greenlam/Merino/T-Line)

341

-

11256

... More
Supply and Installation of Anutone Soak Cord, square edge, two color fabric wrapped vertically(choiced colours), pinewood fiber core panel of size 600x1200x15mm,with ribbed finish, volume density 400Kgs/m3, weight 6kg/m2 installed by using Anutone Strut framework system and Anutone Strut Z bars.The Anutone Strut framework systems includes Anutone Strut CC25 Cross Channel having thickness 0.55mm, length 3600mm, knurled web 35, depth 20mm and equal flanges 15mm is fastened to wall positioned vertically in a regular manner at 600mm c/c. Anutone Strut Z bars having 40mm height, thickness 1mm is first fixed behind the panels by using suitable fasteners. Another length of Strut Z bar to be fastened perpendicular to Strut CC25 Cross Channel at spacing so as to match with that of Strut Z bar rear to panels. Soak cord, square edge panels are then slided on to Strut Z bar fixed on CC25 Cross Channel. (FOR CLASSROOMS, SEMINAR HALL & BOARD ROOM WALL PANELLING). .Anutone or Equivalent make as per prior approval of Engineer-in-Charge.Note: Thickness is given for bare Panels, 4mm for cord fabric.(fabric colour as per choice). The system is backlined with the acoustical infill Anutone SynthPF 10x25.

1056

-

9062

... More
Providing and fixing solid laminated flush door shutters having uniform thickness of 37mm with smooth finish and moisture content 10 to 12% with water absorption of 2%, climate stable, warp and bend free as certified by IS-2202 with 1mm HPL conforming to IS - 2046 including , screws chocks/cleats and stops etc. (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position).(Greenlam, century make, duro) (N.S ITEM).

332

-

3689

... More
Providing and laying Plain Cement Concrete 1:1½:3 viz. M-20 of 150 mm average thickness for Trimix Concrete Flooring, using 25mm down aggregate and thoroughly washed sand, which is free from all foreign materials as approved by Architect/Engineer / Engineers & Poylpropelene Fibremesh of approved make ( 125 gm/ Cement Bag of 50 Kg ). It is to be laid in any thickness, shape or size, as per drawings and specifications.Including all the materials required for formwork, centering and scaffolding wherever required, at all depths and heights. Consolidating the same, including vibrating with needle of surface vibrator. The curing must be done for a period of 7 days. It should be processed with Vacuum Dewatering System, including of surface vibrating and levelling the surface with screed vibrator, vacuum dewatering the surface, power trowelling the surface to make it smooth and finished, including groove cutting upto 20 mm deep and 5 mm wide construction/Expansion joints and making a panel of approx 3.0 mt. x 4.0 mt approx or as approved by Architect/Engineer.This joints is to be filled with polysulphide sealent as approved and directed. (ALL AROUND THE BLOCK) (N.S.ITEM)

1240

-

1377

... More
Providing and laying smooth stone texture paint in colors shade and texture as per approval applied by a coat applied by a spray gun in the desired shade of approved make including sand papering the existing surface of putty, to give it a base for applying primer coat. It also includes scaffolding charges complete in all respect (FOR EXTERIOR FACADE) (N.S.ITEM). of Heritage Paints or Equivalent make as per prior approval of Engineer-in-Charge.

3622

-

965

... More
Providing & fixing Hand shower (Health faucet) with 1.0m long easy flex tube in chrome finish & wall hook (model no. ALD-565) Jaquar or equivalent with prior approval of Engineerin charge.

87

-

1243

... More
Providing and fixing in position two way Bib cock for and hand shower (model CON-041KN) of Jaquar make o or equivalent with prior approval of Engineerin charge. (N.S ITEM)

87

-

1335

... More
Providing and fixing in position Angle Valve (model No.CON-059KN) of Jaquar make or approved by Engineer-in-Charge. (N.S ITEM)

236

-

989

... More
Providing and fixing in position 15 mm i/d wall mounted sink cock with swinging casted round shape spout (Model No.CON-347KN) of Jaquar make or equivalent as per prior approval of Engineer-in-Charge. (N.S ITEM)

13

-

1889

... More
Providing and fixing in position European Type Floor Mounted Water Closet (white) Suit of size(mm), (model (No . CNS-WHT-755SN + CNS-WHT-207 of Jaquar make or equivalent as per prior approval of Engineer-in-Charge. (N.S ITEM), complete in all respects

87

-

10888

... More
Providing and fixing floor drain with jali (pp) as per I.S:14735:1999 marked of Supreme pipes or equivalent with prior approval of Engineerin charge. (N.S ITEM)

51

-

129

... More
Providing and fixing in position Bottle trap (model no.ALD-769L300x190) with internal partition 32mm size with 300mm & 190mm Long wall connections pipes & wall flange and waste coupling(model no.ALD-705L130) 32mm size full thread with 130mm Height of of Jaquar make or equivalent with prior approval of Engineerin charge (N.S ITEM)

157

-

2261

... More
Providing & fixing Pillar Cock long neck with 450mm long braided Hose (model No. CQT -23021B) of Jaquar make or equivalent as per prior approval of Engineer-in-Charge. (NS Item)

107

-

1496

... More
Providing & fixing Wall Hung Basin (model No. CNS-WHT-801) with fixing accessories set size (550x410x195mm) of Jaquar make or equivalent as per prior approval of Engineer-in-Charge. (NS Item)

3

-

5032

... More
Providing and Fixing SWR Fittings (supreme make) for type B pipes 110mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge. (NS Item)FLOOR TRAP WITH TOP TILE & STAINER(125mm)

149

-

318

... More
DOOR TEE

56

-

305

... More
DOOR BEND (TS)

78

-

246

... More
BEND 87.5 °

78

-

210

... More
DOOR CROSS TEE

30

-

413

... More
COUPLER

88

-

165

... More
DOOR CAP

58

-

137

... More
VENT COWL

12

-

174

... More
CLEANOUT

127

-

156

... More
Providing and Fixing SWR Fittings (supreme make) for type B pipes 160mm dia including fixing jointing and testing etc. Supreme make or equivalent as per prior approval of Engineer-in-Charge. (NS Item)DOOR TEE

62

-

631

... More
COUPLER (RIB TYPE)

98

-

279

... More
VENT COWL

12

-

273

... More
DOOR ELBOW

65

-

601

... More
CLEANOUT

5

-

275

... More
Providing and fixing of 1 No. U-shaped rail with wall mounting of (Size: 600x100mm) at fixed height for handicap toilet complete as required. (Make-CERA, Model-2501) (Hindware, Cera, Parryware) (Used in Handicapped toilet) complete in all respect With the prior approval of enginer Incharge

6

-

7140

... More
Providing and fixing of 1 No. Wall Mounted Grab Bar of (Size: 500mm) at fixed height for handicap toilet complete as required. (Make-CERA, Model-2504) (Hindware, Cera, Parryware) (Used in Handicapped toilet) Complete in all respect With the prior approval of enginer Incharge

6

-

5981

... More
Providing and fixing of 1 No. Wall Mounted Grab Bar of (Size: 350mm) at fixed height for handicap toilet complete as required. (Make-CERA, Model-2505) (Hindware, Cera, Parryware) (Used in Handicapped toilet) complete in all respect With the prior approval of enginer Incharge

6

-

3032

... More
Providing and fixing Centralized R.O system with chillar plant of the capacity - 500 litres / hr and storage SS water tank of 5000 litres complete including fixing in position ( All pumps working with standby provision). (TERRACE) (MAKE:Aquagard,ionchange or equivalent ISI Mark) (Used at Terrace) With the prior approval of enginer Incharge

1

-

1120343

... More
Providing and Fixing automatic 'NO-Touch ' electric hand-driers complete with all accessories & fittings. (Make: Jaquar Model No. HDR-SAP-M99ACS) (Jaquar, Euronics & Kingston) (Used in Toilets) With the prior approval of enginer incharge)

12

-

21222

... More
Providing and Fixing automatic 'NO-Touch ' electric hand-driers complete with all accessories & fittings. (Make: Jaquar Model No. HDR-SAP-M99ACS) (Jaquar, Euronics & Kingston) (Used in Toilets) With the prior approval of enginer incharge)Submersiable Centrifugal Non-clog Drainage Pump - Supply, installation, testing and commissioning of continuous duty submersible centrifugal non-clogging drainage/sewage pumps complete with 3 phase motor with all necessary protection and mechanical seal etc. complete with all ancillaries including float type level controllers, electrical control panels fabricated from 14 gauge CRCA sheet volt meter ammeter with selector switch, TPMCB, 5 VA CL : CTs, phase indicating lamps protected by 2 amp SP MCB, DOL starter, necessary wiring, cable alleys, earthing, interlocking, starter with Automatic float type level controller, providion of high level alarm, sequence timer, potential free contact to starter for connection to BAS, both pumps may run simultaneously at pre determind level. Nos. of Pumps : 2 nos (1 w+ 1 s)Water Flow Rate : 5 LPS each pumpHead : 15 MLocation : Drainage Sump Pump for Basement

1

-

192641

... More
Nos. of Pumps : 2 nos (1 w+ 1 s)Water Flow Rate : 2 LPS each pumpHead : 15 MLocation : Sewage Sump Pump for Basement

1

-

192641

... More
Supply, installation , testing & commissioning of UPVC (Class III) of pressure rating 6 bar for waste pipe connection for washbasin/urinals/sinks conforming to IS:4985 cut to required lengths including all necessary fittings and specials. Fixing at wall/ceiling level all type of supported by MS hot dipped galvanised angle support for vertical and horizontal pipe fixing with GI u clamp & hangers etc. Cutting chases/holes in floors/walls/slab etc. Supreme or equivalent make as per prior approval of Engineer-in-Charge. (NS Item)40 mm dia (6 bar pressure rated)

71

-

154

... More
50 mm dia (6 bar pressure rated)

175

-

223

... More
Providing and fixing motorized valve including control wiring upto panel & ON/OFF arrangement and all other accessories required to make the system complete including control unit to be made of good quality PVC box, as per IP 65 with cable gland also as per IP 65 and suitable for outdoor installation complete with suitable wiring. This unit should be suitable to operate solenoid valve, float switch and consisting of contactors, control transformer, MCB, Potential free contacts for BMS, indicating lamp for automatic operation of filling OH tank with level to be maintioned between 70% (low) to 100% (full) 50 mm nominal bore

2

-

31762

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. (Make-Tata / Jindal (Hissar) / SAIL) With the prior approval of Engineer Incharge (Location - Basement / Fire Shaft) (HSR-22.88 )80 mm dia nominal bore. (DSR-18.12.7)

20

-

968.49

... More
LT PANEL: Supply, unloading, installation, testing and commissioning of the following cubical type panels made of 2.0 CRCA structure, base channe lSMC, doors & sheet metal partitions complete with, Moulded Case Circuit Breakers, meters, indicating lamps, current transformer, control MCB etc. Complete in all respects, insulated bus bars with heat shrinkable PVC sleeve, supported on FRP/ SMC supports in suitable bus chambers, interconnection, small wiring, name plate, danger plate, earth bus etc. & comprising of compartments with hinged door for each feeder & its accessories, cable alley with hinged doors, bus chamber with bolted door etc. The panel being of dust & vermin proof construction with rubber gasket, attractively powder coated with Approved Paint shade. The panel shall be free standing type/ wall mounted type as per relavant drawing and comprising with foundation & Masonary works including ducting. Note:- Breaking Capacity of all MCCB's are Ics Service Breaking Capacity.MCCB's upto 250A shall be with Adjustable thermal-magnetic and above 250A Microprocessor based adjustable release. All MCCB's shall be Front door operating handle, Phase Spreaders & Phase Barriers. TPN MCCB Shall mean 3Pole MCCB with Adequate size of separate neutral link. Metering CTs burden shall be 15VA & accuracy class 1.0. CTs shall be "CAST RESIN" type. All indication lights shall be LED type. All meters shall be "DIGITAL" type. Degree of Protection for Indoor panels shall be IP-55 with canopy and double for Outdoor Panels, cable entry from bottom only. Panel space heaters with control MCB & Thermostat, covered CFL lamp controlled by door switch for each panel bay. Gland plates shall be 2mm thick for LT. Panels upto 400A Incomer & 3 mm thick for LT. Panel with 630A & above incomer. Panel Manufacturer should have Type Test Certificates for Short Time withstand current test of 50kA for 1.0 Sec from CPRI Bhopal/ Bangalore. "ON" Indicating lamp shall be provided for all 3 phase MCCB out going feeders unless otherwise specified. Control SP MCB's of 2/4A Rating shall be provided for each metering circuit.BUILDING MAIN PANEL - Incoming: 1 No. 1250 Amp FP MDO Air Circuit Breaker (of 50kA Ics Value) with microprossor release for O/L, S/C & E/F protection. Bus bars - 1 Set of 1500-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). Metering & Indication: One set of R/Y/B phase indication Lamp & MCB. 1 No. Multi Function Meters (A/V/kW/kWh). ON/OFF/TRIP indication lamp for incomer. Outgoing: 3 Nos. 400 Amp TPN MCCB of 36 KA with overload, S/C protection. 1 Nos. 250 Amp TPN MCCB of 36 KA with overload, S/C protection. 1 Nos. 160 Amp TPN MCCB of 36 KA with overload, S/C protection. 1 Nos. 160 Amp TPN MCCB of 36 KA with overload, S/C protection. 17 Nos. 100 Amp TPN MCCB of 25 KA with overload, S/C protection. Panel as mentioned above should be complete in all respect with internal wiring, al. bus bar etc. (FOR WHOLE BUILDING, AT BASEMENT) (NS ITEM)

1

-

833979

... More
Floor L+P Panel (Panel for Gnd, 1st, 2nd, 3rd, 4th ,5th & 6th Floor): Incoming - 1 Set of 100 Amps. 415 Volts, FP MCCB of 25 KA with overload, O/V, O/C and earth fault protection. Bus bars: 1 Set of 160-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). Metering & Indication: One set of R/Y/B phase indication Lamp & MCB. 1 No. Multi Function Meters (A/V/kW/kWh).ON/OFF/TRIP indication lamp for incomer. Outgoing: 3 Nos. 63 Amps. TPN MCB of 10 KA. 3 Nos. 40 Amps. TPN MCB of 10 KA along with kWh meter for each feder. Panel as mentioned above should be complete in all respect with internal wiring, al. bus bar etc. (AT FLOOR ELEC. ROOM) (NS ITEM)

5

-

131616

... More
UPS Output Panel: Incoming - 3 Set of 100 Amps. 415 Volts, FP MCCB of 25 KA with overload, O/V, O/C and earth fault protection for 3Nos. 40kVA UPS. Bus bars: 1 Set of 200-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). Metering & Indication: One set of R/Y/B phase indication Lamp & MCB. 1 No. Multi Function Meters (A/V/kW/kWh).ON/OFF/TRIP indication lamp for incomer. Outgoing- 3 Nos. 63 Amp TPN MCCB of 25 KA with overload, S/C protection. 10 Nos. 40 Amps. TPN MCB of 10 KA. 7 Nos. 25 Amps. TPN MCB of 10 KA. Panel as mentioned above should be complete in all respect with internal wiring, al. bus bar etc. (AT UPS ROOM) (NS ITEM)

1

-

247241

... More
Common Services Panel : Incoming - 1 Set of 100 Amps. 415 Volts, FP MCCB of 25 KA with overload, O/V, O/C and earth fault protection. Bus bars: 1 Set of 160-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). Metering & Indication: One set of R/Y/B phase indication Lamp & MCB. 1 No. Multi Function Meters (A/V/kW/kWh).ON/OFF/TRIP indication lamp for incomer. Outgoing: 3 Nos. 63 Amps. TPN MCB of 10 KA. 6 Nos. 40 Amps. TPN MCB of 10 KA. Panel as mentioned above should be complete in all respect with internal wiring, al. bus bar etc (FOR WHOLE BUILDING, AT BASEMENT) (NS ITEM)

1

-

76264

... More
LIGHT FIXTURES & FAN: Supply, Installation, Testing & Commissioning of luminaires basic channel, holder, LED driver (as per mentioned in item), starter, condenser, control gear box complete with decorative attachments, lamps etc. as per specifications and as per catalogue number giving below.30 Watt 2'x2' Recessed Mounted LED Light Fixture. Liminaire should be extruded/PDC housing of Aluminium, THD less then 10%. Wipro Cat Ref. CRCO10R030HP57HEKS - 30W / 3600lm, Philips and Havells make with prior approval of Engineerin charge. (FOR CON. HALL, LAB, CLASS. MEETING, SE. FAC. ROOM ETC) (N.S ITEM)

700

-

5022

... More
25 Watt LED Downlighter (Adjust 60 Deg) light fixture. Liminaire should be extruded/PDC housing of Aluminium, THD less then 10%. Wipro 25W Orbit - LM23O-671-XX-57-XW - 3125lm Philips and Havells make with prior approval of Engineerin charge. (NS ITEM)

2

-

8975

... More
20 Watt LED Downlighter (Adjustable 60 Deg) light fixture. Liminaire should be extruded/PDC housing of Aluminium, THD less then 10%. Wipro- LD56-251-060-57-XX 2000 lm or ,Philips & Havells make with prior approval of Engineerin charge. (NS ITEM)

2

-

5121

... More
15 Watt LED Recessed type LED downlighter. Liminaire should be extruded/PDC housing of Aluminium, THD less then 10%. LD06-171-XXX-57-XX - 1500lm Wipro, Philips & Havells make with prior approval of Engineerin charge. (FOR CIRCULATION AREA) (NS ITEM)

565

-

3832

... More
15 Watt LED Surface Mounted LED downlighter. Liminaire should be extruded/PDC housing of Aluminium, THD less then 10%. Wipro LD06-171XXX-57SMG1 - 1500lm, Philips and Havells make with prior approval of Engineerin charge.

170

-

4107

... More
15 Watt LED Surface Mounted LED downlighter. Liminaire should be extruded/PDC housing of Aluminium, THD less then 10%. Wipro LD06-171XXX-57SMG1 - 1500lm, Philips and Havells make with prior approval of Engineerin charge. (FOR STAIRCASE)

50

-

2242

... More
9 Watt LED Bulk-Head light fixture. Liminaire should be extruded/PDC housing of Aluminium, THD less then 10%. Wipro - LW07-141-XXX-57-G1,Philips and Havells make with prior approval of Engineerin charge. (FOR SHAFT & TERRACE)

85

-

2348

... More
36 Watt Surface mounted batten LED Light fixture. Liminaire should be extruded/PDC housing of Aluminium, THD less then 10% Wipro LL24-541-XXX-57-XX - (110lm/w), Philips and Havells make with prior approval of Engineerin charge. (FOR BASEMENT & SERVICES ROOM)

70

-

836

... More
11 Watt Surface mounted 600mm length LED Mirror Light fixture. Philips and Havells make with prior approval of Engineerin charge. (FOR TOILET)

10

-

725

... More
11 Watt LED Bollard Light fixture, Luminaire should be extruded/PDC housing of Aluminium, THD less then 25%. Wipro LB14-131-XXX-30-08 - (70 lm/w), Philips and Havells make with prior approval of Engineerin charge. (FOR LANDSCAPE)

10

-

13129

... More
15 Watt LED Surface Mounted LED downlighter (Outdoor Type, IP-66). Liminaire should be extruded / PDC housing of Aluminium, THD less then 10%. Wipro LD08-291-060-30 SM - (100 lm/w), Philips and Havells make with prior approval of Engineerin charge. (FOR BUILDING OUTSIDE CLADING)

2

-

5478

... More
FANS, EXHAUST FANS, CABIN FANS AND SOCKETS: Supply, Installation, Testing & Commissioning of Exhaust fans/ wall fan/ Ceiling Fans of following sizes including making the holes to suit the size of the fan and making good the damages, including providing and fixing of louvers/ shutters, connection, testing and commissioning. (N.S.ITEM)Ceiling Fan 1200 mm white color 2 Star, ISI Marked Specifications Havells - ES Plus , Usha, Orient, Crompton make with prior approval of Engineerin charge. (FOR CON. HALL, LAB, CLASS. MEETING, SE. FAC. ROOM ETC) (NS ITEM)

450

-

3936

... More
Wall Fan 600 mm , Industrial Wall Air Circulator Fans. Crompton, Almonard, Usha make with prior approval of Engineerin charge. (NS ITEM)

2

-

13212

... More
300 mm Sweep (900 RPM), Havey duty Exhaust fan with Louver suitable for operation on 1-Phase. Crompton, Almonard, Usha make with prior approval of Engineerin charge. (NS ITEM)

2

-

5550

... More
Supplying Supply, Installation, Testing & Commissioning of following size Industrial socket outlet (outdoor type), IP-66, complete in all respects as required.32 Amp, 3-phase Industrial Socket (NS ITEM)

2

-

6046

... More
40KVA UPS (For UPS POWER SOCKETS & EM. LIGHTING): Supply, unloading, installation, testing and commissioning of 40kVA IGBT based ON line UPS (in-put 3-Phase and out-put 3-Phase) with external extra Sealed maintenance free Batteries for 30 min. backup with the following with all required assecories & Masonary works. Operating Environment 0 - 35 Deg C, operating relative Humidity 20 - 80%, operating Elevation 0 to 99.9 meters, Storage Temperature- 10 - 40Deg C, storage Elevation 0 - 9000 meters, Regulatory Approvals CE, ISO 14001/ 9001. (Conf. N+1). Fuji/ Numeric/ Socomec/ Delta/ TMEIC make with prior approval of Engineerin charge. (FOR WHOLE BUILDING, AT UPS ROOM) (NS ITEM)

3

-

2035204

... More
LIGHTNING PROTECTION AS PER IEC 62305/ NBC 2016 AT LVL -II (10X10 MTR )Supply of Vertical Aluminium Lighting Arrester of 16MM dia, 2000 mm long with Gun Metal base plate and 2 mtr GI Pipe. Model : APSAT416AL+APSTB16-253 Make : APS

3

-

4182

... More
Supply 8 mm round aluminium conductor for horizontal lightning protection - run in roof. Model : AL8. Make : APS

400

-

117

... More
Supply of roof conductor holder for 8 mm round aluminium conductor made of SS 304 for horizontal installation. The distance between each holder should be min of 1 mtr. Model : APSRCHSS50. Make : APS

400

-

143

... More
Supply of T/Cross connector for connecting of 8 mm Al round conductor. The connector should be of SS 304 with SS nuts and bolt. Model : APSCCTSS50, Make : APS

20

-

382

... More
Supply of Expansion piece along with connector to compensate the expansion of round 8 mm Al conductor when temperature variation. Connection should be in every 20 mtr. Model : APSEXP50, Make : APS

20

-

335

... More
GLUE- Glue is used to fix roof conductor holder on roof.

2

-

454

... More
DOWN CONDUCTOR & RING CONDUCTOR AS PER IEC 62305 (FOR WHOLE BUILDING, AT BUILDING FAÇADE & EXTERNAL)Supply of 8 mm round aluminium conductor as a down conductor mounted in the surface of wall which will carry the lightning current to earth pit. Model : AL8. Make : APS

500

-

117

... More
Supply of Down conductor holder made of SS 304 for 8 mm round aluminium conductor of min distance between the wall to the conductor will be of 85 mm. The distance between each holder should be min of 1 mtr. Model : APSDCHSS50 Make : APS

450

-

143

... More
Supply of straight connector for connecting of 8 mm Al round conductor. The connector should be of aluminium with SS nuts and bolt. Model : APSPCRC50, Make : APS

50

-

335

... More
Supply of 7 digit lightning strike counter. Model - LSR2 Make - LPI

2

-

19716

... More
Supply of Test Joint Point for 25X3MM CU STRIP, the size should be of 25 x 3 x 150 mm copper in ABS boxes. Model : APSTLBCU. Make : APS

2

-

2211

... More
EARTHING AS PER IEC 62561- 2 & 7 (FOR WHOLE BUILDING, AT EXTERNAL)SITC of Galvanised Steel Flat 25X3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/ 305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx: 70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding complete etc as reqd.

240

-

299

... More
Supply of advance chemical gel earthing system for the proper dissipation of fault/ leakage current to the ground and ensure the continuous electrical connectivity and proper functioning to the electrical system. The earth rod shall be of UL listed & CPRI tested 3 meter long 25.4 mm dia 250 microns copper bonded steel rod with the connecting clamp (ss - rod to tape). The UL listed copper bonded rod also should be tested & ceritifed from CPRI for a short circuit current of 50kA or more. The UL listing shall be punched/ engraved on the rod for the physical verification at site. The engravings shall contain the following details-UL Control number, Dimension details of the rod, Product model number & UL certificate reference number as per detailed technical specification attached. To ensure the electrical conductivity, 50 Kgs (per pit) or more resistance grounding minerals per earth pit/ earth rod shall be used along with the copper bonded rod. As per IEEE 80-2013 (Clause 14.5 d), the grounding minerals shall be tested & certified for the resistivity of less than 0.12 ohm-mtr. The grounding minerals should be ROHS certified to ensure it does not pollute the ground water as per technical specification attached.

18

-

10515

... More
FIRE DETECTION SYSTEM: (FOR WHOLE BUILDING)FIRE DETECTION & PUBLIC ADDRESS SYSTEM (UL, EN & ULC Listed and FM Approved) HONEYWELL- NOTIFIER/ EATON/ SIEMENS make with prior approval of Engineerin charge. (NS ITEM)Supply, unloading, installation, testing and commissioning of Micro processor based. Intelligent Addressable 10 Loop Main Fire alarm panel, Central Processing Unit, with each loop capacity of 120 detector per loop with total of 240 detectors and devices with loop length up to 2 kmtr, network communication card, minimum 320 character graphics, LCD display with touch screen or other keypad and 1000 event history logs in the non volatile memory (EEPROM) power supply unit at 230+ 5 % V, 48 Hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout logs and facility to have integration with analog voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel should be compatible for integration with IBMS system with open protocol Bacnet/IP, complete as per specs and as required for following loops. (NS ITEM)

1

-

894224

... More
REPEATER PANEL: Supplying, of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. ( NS ITEM)

1

-

182406

... More
DETECTORS: SITC of Intelligent Addressable Multi-Sensor (Optical Smoke) detector with base. The optical sensor element shall have multiple selectable sensitivity levels from 0.2% Obs/ft to 3.7% Obs/ft. The ROR detection element shall have selectable rate of rise setting of 8°C per minute & 11°C per minute (or close to this value not deviating more than 1°C). Fixed temp detection element shall have two selectable settings of 57°C and 68°C (or closer to this value not deviating by 1°C). Multis-sensor detector shall have a configuration mode that gives separate alarms for smoke detection and heat detection and shall indicate the cause of alarm (smoke or heat). Also the multi-sensor shall have combined configuration mode of smoke and heat detection that gives only one evaluated alarm from a multi-sensor detector in case of a fire event. The detector shall have operating temperature range from -9°C to 50°C and humidity tolerance range up to 95% RH, Non-Condensing. (Above False Ceiling) (NS ITEM)

350

-

4739

... More
SITC of Intelligent Addressable Multi-Sensor (Optical Smoke) detector with base. The optical sensor element shall have multiple selectable sensitivity levels from 0.2% Obs/ft to 3.7% Obs/ft. The ROR detection element shall have selectable rate of rise setting of 8°C per minute & 11°C per minute (or close to this value not deviating more than 1°C). Fixed temp detection element shall have two selectable settings of 57°C and 68°C (or closer to this value not deviating by 1°C). Multis-sensor detector shall have a configuration mode that gives separate alarms for smoke detection and heat detection and shall indicate the cause of alarm (smoke or heat). Also the multi-sensor shall have combined configuration mode of smoke and heat detection that gives only one evaluated alarm from a multi-sensor detector in case of a fire event. The detector shall have operating temperature range from -9°C to 50°C and humidity tolerance range up to 95% RH, Non-Condensing. (Below False Ceiling) (NS ITEM)

5

-

4739

... More
SITC of Intelligent Addressable Multi-Sensor (Optical Smoke+Heat) detector with base. The optical sensor element shall have multiple selectable sensitivity levels from 0.2% Obs/ft to 3.7% Obs/ft. The ROR detection element shall have selectable rate of rise setting of 8°C per minute & 11°C per minute (or close to this value not deviating more than 1°C). Fixed temp detection element shall have two selectable settings of 57°C and 68°C (or closer to this value not deviating by 1°C). Multis-sensor detector shall have a configuration mode that gives separate alarms for smoke detection and heat detection and shall indicate the cause of alarm (smoke or heat). Also the multi-sensor shall have combined configuration mode of smoke and heat detection that gives only one evaluated alarm from a multi-sensor detector in case of a fire event. The detector shall have operating temperature range from -9°C to 50°C and humidity tolerance range up to 95% RH, Non-Condensing.

1

-

4739

... More
RESPONSE INDICATORS: Supply of Response Indicators with Single LED. ( NS ITEM)

150

-

358

... More
MANUAL CALL POINT: SITC of Intelligent Addressable Manual Pull Stations/ Manual Call Points suitable for wall/ column mounting. MCP shall have red coloured housing with molded, raised-letter operating instructions of contrast colour. The MCP shall latch mechanically upon operation and shall remain so until manually reset with its key by an authorized operator. The MCP shall have operating temperature range from 0°C to 50°C and humidity tolerance range up to 93% RH, Non-Condensing.( NS ITEM)

14

-

4616

... More
FAULT ISOLATOR: SITC of Intelligent Addressable, Supervised Short-Circuit Isolator. The Isolator Monitor Module shall have operating temperature range from 0°C to 49°C and a humidity tolerance of up to 90% RH, Non-Condensing. ( NS ITEM)

20

-

3031

... More
Sounder: SITC of Addressable Notification Devices (Hooter with Strobe). Hooter with Strobe unit shall sit directly on addressable NAC (Notification Appliance Circuit) of FACP, fully supervised and powered from FACP. Hooter and Strobe elements of the combined unit shall have independent activation & deactivation criteria. Hooter shall stop at alarm "Acknowledge" and the Strobe shall stop at panel "Reset". The Hooter and Strobe element of Hooter cum Strobe combined unit shall be selected and triggered independently from FACP for performance check and maintenance. Hooter with Strobe unit shall have provision to be tested by a hand-held field diagnostic tool in "Silent Mode" and "Full Operation Sound Mode". The Strobe shall have multiple selectable candela settings configured and selected from the FACP. The hooter cum Strobe unit shall deliver output up to 94 db. at 3m from its installed location. The sounder/ strobe unit shall display the voltage received by them at the control panel. The activation & deactivation requirement of Notification devices shall not be deviated. No external 3rd party power supply shall be permitted. (NS ITEM)

14

-

7259

... More
POWER SUPPLY: Supply, installation, testing & commissioning of 5A power supply which operates on 220 V 50 Hz power supply with 24 V DC supply with built in battery and battery charges for 2 hours backup. Power supply is for powering hooters/strobes. (NS ITEM)

1

-

5387

... More
MODULES: SITC of Intelligent Addressable, Supervised Monitor Module monitoring Potential-free, Normally Open Dry Contact input. The Monitor Module shall have operating temperature range from 0°C to 70°C and a humidity tolerance of up to 93% RH, Non-Condensing. UL EN & ULC Listed and FM make with prior approval of Engineerin charge. (NS ITEM)

30

-

4746

... More
SITC of Intelligent Addressable Potential-free, Form-C, SPDT contact based control module to trigger 3rd party utilities like Pressurization fan activation, Special notification activation etc. The contact shall be rated for 2A@24Vdc (Resistive) & 1A@24Vdc (Inductive). The control module shall have operating temperature range from 0°C to 49°C and a humidity tolerance of up to 93% RH, Non-Condensing. UL EN & ULC Listed and FM with prior approval of Engineerin charge. (NS ITEM)

40

-

4881

... More
CABLE: Supply and laying of 2 core 1.5 Sq mm stranded plain annealed copper conductor glass mica taped, XLPE insulated, LSZH inner sheathed, galvanised steel wire armoured and over all LSZH out sheatheated fire survival cable generally as per BS:7846:2009 including connections etc as required. The cable will be fixed on surface with suitable saddles at an interval of not more than one meter. (NS ITEM)

5500

-

211

... More
FIRE EXIT SIGN;Supply of emergency fire exit sign boards, with both side display provision with suitable hanging arrangment complete in all respect as required. (NS ITEM)

15

-

6313

... More
PA SYSTEM: (FOR WHOLE BUILDING)SITC of Microprocessor based Voice Alarm System Controller & Router suitable for 8 zones having built in 240 W amplifier, Freq. response 60 to 18000 Hz, distortion 1%, S/N Ratio 75 having memory capacity 16MB flash ROM, Max messages 255. Controller shall be EVAC Compliant, and as per EN-54-16, EN608-49 ( and recording the Massages given by user department in required format in minimum three languages and store in ROM as per software required format. ( NS ITEM)

1

-

384675

... More
SITC of 19" rack mountable 480W Power Amplifier complete with LMT, control wires and other accessories. ( NS ITEM)

3

-

65148

... More
SITC of the announcement console/ call station with microphone suitable for 8 zones. The unit shall be suitable for expansion of at least 6 additional zones (NS ITEM)

1

-

61450

... More
SITC of 6W Ceiling mounted speakers with built in 100/70v LMT, variable wattage tapping with required mounting accessories & hardware to mount in false/ true ceiling. (NS ITEM)

236

-

1851

... More
SITC of 6 W Wall mountable speaker with built in 100/70v LMT, variable wattage tapping of 10/6/3/1.5 watts with required mounting accessories & hardware to mount on wall/ ceiling/ pole. (NS ITEM)

6

-

2120

... More
Supply of 2 core 1.5 Sq mm stranded plain annealed copper conductor glass mica taped, XLPE insulated, LSZH inner sheathed, galvanised steel wire armoured and over all LSZH out sheatheated fire survival cable generally as per BS:7846:2009 including connections etc as required. The cable will be fixed on surface with suitable saddles at an interval of not more than one meter. (NS ITEM)

2100

-

211

... More
SITC 9U, wall mounted type standard alluminium Rack with front Acrylic door and lock, rear door with lock, wired power and signal Channel duly powder coated. (NS ITEM)

1

-

23887

... More
CCTV SYSTEM : (FOR BUILDING ENTRY & EXIT, CIRCULATION AREA)CCTV HONEYWELL/ BOSCH/ PELCO/ HEINRICH: Supply, installation, testing and commissioning of of  IR indoor Dome type, 1/3" 4 MP, progressive scan dual Streaming: H.265 smart codec, dual stream support, 2688 x 1520 resolution, Auto lens detection (2.7-13.5 mm), compatible with digital video recorder, PoE (802.3af) or 12 VDC support, UL/CE Listed, ONVIF conformant with IP 66 weather proof housing and 30 mtrs IR range. Honeywell or eqv. with prior approval of Engineerin charge. (NS ITEM)

25

-

16389

... More
SITC of  IR indoor bullet type, 1/3" 4 MP, progressive scan dual Streaming: H.265 smart codec, dual stream support, 2688 x 1520 resolution, Auto lens detection (2.7-13.5 mm), compatible with  digital video recorder, PoE (802.3af) or 12 VDC support,UL/CE Listed, ONVIF conformant with IP 66 weather proof housing and 50 mtrs IR range. Honeywell cat no. HBW4PER2 or eqv. with prior approval of Engineerin charge. (NS ITEM)

4

-

17733

... More
Supply, Installation, Testing and commissioning  of 64 Channel NVR (Network Vedio Recorder), for recording upto 64CH @ 1080P with 08 nos. SATA HDDs minimum 80TB storage or more (recording requirement all cameras recording at 2MP, 25fps for 30 days),H.265/H.264/MJPEG/MPEG4 codec decoding, Front Control Pannel with LEDs Indication, 3 nos. USB, iPhone; iPad; Android based Mobile clients, Video Export feature on USB, Search Mode: Time/Date; Alarm; Motion Detection (MD); Exact Search (accurate to a second); Smart Search, Dual HDMI Output, Alarm Input (16 nos.), Alarm Output (4 nos.), eSATA Device, 320Mbps each Incoiming & Outgping throughput, Operating Temperature –10°C to 55°CCertification : CE, FCC & UL including fixing accessories and cable termination with required connectors/Jack, complete in all respect as per instruction of engineer in-charge

1

-

221059

... More
SITC of of 6TB Survillance Hard Disk of SEGATE/WB/SAMSUNG make with prior approval of Engineerin charge. ( NS ITEM)

1

-

26576

... More
Supply, Installation, Testing and Commissioning of 16 port L2 web Managed switch having port density 16 Nos. of 10M/100M/1G RJ45 Port POE/POE+ ports, 2 Nos. of 1G/10G SFP Ports, 1X console port, Available POE power 370 W, 128 Gbps switching bandwidth, 16K MAC address support. DLINK/CISCO/HP make with prior approval of Engineerin charge. (NS ITEM)

5

-

62819

... More
Supply, Installation, Testing and commissioning of 18 U floor mount rack with fans, 2 cable managers, stationary shelf, 2 Nos of hardware pkts. DATA RACK/ OMNITECH /RITTAL make with prior approval of Engineerin charge. (NS ITEM)

1

-

55282

... More
Supplying and laying of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair CAT6 Unshielded, Twisted Pair (U/UTP) Cable. Blue in colour conforming to the following standards like ANSI/TIA 568 C.2, EN50173, IEC 11801 2nd ED, 700Mhz etc. in Cat 6 U/UTP LCS2 cable with 23AWG . DLINK/LEGRAND/MOLEX make with prior approval of Engineerin charge. (NS ITEM)

1400

-

87

... More
Supply, Installation, Testing and Commissioning of Full HD 32" LED Professional Display Panel. SONY/LG/SAMSUNG (NS ITEM)

3

-

55396

... More
FLOOR RACEWAY: (FOR FLOOR LEVEL, POWER & ELV DISTRIBUTION)Supply, laying of following sizes GI Raceway complete with all accessories including junction box with 3 mm thick cover plate, neoprene gasket in joints, cutting the floor and jamming the raceway with all necessary hardware (including civil works) as required. MEM/ OBO/ BEC make with prior approval of Engineerin charge. (NS ITEM)50 x 40 mm

150

-

904

... More
100 x 40 mm

200

-

999

... More
200 x 40 mm

50

-

1525

... More
TELEPHONE SYSTEM: (AT ELEC./ ELV ROOM) Supply installation and testing and commissioning of follwing size of Telephone distribution board in a M.S. box with hinged cover/ door complete with krone type tag block with double jumpering facility mounted on a bakelite sheet etc. including terminations of cable as required. (NS ITEM)10 Pair telephone distribution board

4

-

2156

... More
20 Pair telephone distribution board

4

-

3593

... More
200 Pair telephone distribution board

1

-

22543

... More
Supplying and laying of following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, armored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. (NS ITEM)10 Pair

500

-

292

... More
20 Pair

120

-

441

... More
200 Pair telephone distribution board

100

-

2658

... More
Supply, Installation, Testing and Comissioning of L2 Managed switch having port density as 16 Nos of 1G/ 2.5G RJ45 Port POE+ ports, 32 Nos of 10M/100M/1G Port PoE+ and 4 Nos of 10G/ 25G QSFP Port, 1X RJ45 console, 1x USB Console port, 1x Dedicated OOB port, Available POE power atleast 740 W even if one PSU fails, Dual Internal Replaceable Power and Fan Support fully populated. 344 Gbps switching bandwidth, 32K MAC address support, Support L2 feature STP, RSTP, MSTP. Support 802.1Q VLAN, port based VLAN, 4K Active VLAN entries, MAC based VLAN, Support IEEE 802.3ad LACP. upgradable L3 features - OSPF, VRF and VXLAN. should support Stacking support of 100Gbps per switch. Stacking accesories to be provided on day 1. Must have Common criteria certification NDcPP/ NDPP/ TEC certified (DoT, India), PoE port should not power cycle if switch is rebooted. Switch should be quoted with 5years OEM warranty and 5 years remote TAC support. (AT ELEC./ ELV ROOM)

2

-

568662

... More
Supply, Installation, Testing & Commissioning of Indoor Access Point, should have integrated dynamic packet capture, WIPS, detection of rouge Access Point detection, support standalone/ Cloud Controller/ Hardware controller/ Virtual Controller. 4x4 MU-MIMO on 5Ghz band with WiFi-6 support with 2.9Gbps overall bandwidth. Should support atleast 1 nos of 1G/ 2.5Gbps ethernet port, Should support upto 30 SSIDs per AP. Must be able to limit per SSID or per user based uplink or downlink bandwidth, as per detailed specification of management controller etc., complete as required. Access should be WiFi Certified, TEC certified, RoHS certified. Operating temperature 0-50 Deg C. AP's should come with 5 years OEM warranty & 5 years OEM TAC support. (FOR WIFI POINT, CIRCULATION AREA)

20

-

105210

... More
Supply, Installation, Testing and Commissioning of wireless Controller with AI supported mechanism for managing Wireless Access Points and Network Switches as well. should have support for AI/ ML based analytics for quick resoulution and troubleshooting. should support minimum of 2000 APs per appliance, Should have inbuilt BYOD and guest access features, should support user database of 5000 users upgradable to atleast 10000 users. if these function are provided in other product being provided else where, bidder can mark it included in said item. Wireless Controller should be TEC certified . WLC should be quoted with 5 years OEM warranty and 5 years OEM TAC support. (AT ELEC./ ELV ROOM)

1

-

1858118

... More
L.T. CABLES SUPPLY (POLYCAB/KEI/RR KABEL: Supply of the following 1100 Volts Al/ Cu. Conductor, PVC insulated PVC sheathed, steel armoured/ unarmoured or XLPE cables as per IS-1554/ 7098 Part- I and as per standard specification (FOR WHOLE BUILDING, CONNECTING TO PANEL & DB'S) (NS ITEM)3.5 core 300 sq.mm AL. XLPE ARM CABLE

400

-

2401

... More
3.5 core 185 sq.mm AL. XLPE ARM CABLE

100

-

1502

... More
3.5 core 120 sq.mm AL. XLPE ARM CABLE

100

-

1014

... More
3.5 core 35 sq.mm AL. XLPE ARM CABLE

350

-

369

... More
4 core 25 sq.mm AL. XLPE ARM CABLE

20

-

326

... More
4 core 6 sq.mm CU. XLPE ARM CABLE

1000

-

443

... More
4 core 10 sq.mm CU. XLPE ARM CABLE

250

-

705

... More
1 core 25 sq.mm CU. XLPE UNARM CABLE

400

-

527

... More
Supply of Fire Survival armoured cables of 600/ 1000V rated with Copper circular conductor having glass mica fire barrier tape covered by an extruded layer of XLPE GP 8 insulation and LSZH inner & outer sheath. Generally as per BS 7846, IEC-60502-1 & BS-8519 (latest edition). Should retain circuit integrity as per BS 8491:2008 (120 mins) for cables having overall dia of 20mm and above. Cables with overall dia below 20 mm should retain circuit integrity as per BS 8434-2. Cable shall be manufactured as per TUV/ BRE/ LPCB certification. (FOR WHOLE BUILDING, CONNECTING SAFETY EQ. FROM PANEL)4 core 4 sq.mm CU. XLPE FS ARM CABLE

150

-

517

... More
4 core 6 sq.mm CU. XLPE FS ARM CABLE

150

-

735

... More
MISCELLANEOUS ITEMS : Supply and Installation of First aid box as approved by St. John Ambulance Brigade/ Indian Red Cross conforming to IS : 2217-1963. (FOR ELEC. ROOM) (NS ITEM)

7

-

5226

... More
Supply and Installation of Shock treatment chart in Hindi and English duly mounted on a wooden frame with glass. (FOR ELEC. ROOM) (NS ITEM)

6

-

1183

... More
Supply and Installation of Rubber mat 1m x 2m x 3mm. thick to withstand 1.1 KV dielectric strength as per IS : 5424 - 1969. (FOR ELEC. ROOM) (NS ITEM)

30

-

2930

... More
Supply and Installation of Rubber gloves of 1.1 KV grade as per IS 4770-68. (FOR ELEC. ROOM) (NS ITEM)

5

-

914

... More
LIFT WORKS Supplying, Installation, Testing & Commissioning of 16 Passanger Lifts (1088 kgs) lifts Machine room less type & gearless having contract speed of 1.0 Metres Per Second serving 8 floor in the lift shaft as per detailed specifications enclosed and as under (Makes: Kone, ECE, Schindler, Johnson, Toshiba) :-Location of Lifts : Lift Core Speed -1.0MPS.Floors - 8 (Basement, Gnd Floor to 5th Floor & Terrace Floor).Travel - 28.0 Metres (approx).Stops & opening - 8 Stops (Basement, Gnd Floor to 5th Floor & Terrace Floor). & 8 Opening on same side.Controller: AC variable voltage & variable frequency.Automatic rescue device complete with dry maintenance free batteries as required.Operation: Microprocessor based single automatic push button Duplex collective selective with/ without attendant.Power - 415 V, 3 phase, 50 Hz, 4 wires system.Type of doors :Car: Power operated, centre opening horizontal sliding or telescopic door opening in stainless steel hairline finish with texture.Landing doors: Power operated, centre opening horizontal sliding in stainless steel hairline finish with texture.A hand rail not less than 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.Provision for CCTV, Intercom etc. to be provided along with BMS compitable.

3

-

4144853

... More
M S PIPE , VALVES AND FITTINGS: Supply & installation of ISI marked single headed 63 mm dia gunmetal hydrant valve, 80mm dia flanged inlet with 63 mm female instantaneous outlet confirming to IS”5290 on the fire wet riser/down corner, including making 80NB pipe connection with riser along with 100 mm dia dial pressure gauge of calibration 0-15 Kg/sqmm fixing the landing valves in proper positions including supply of nuts, bolts gaskets, caps chains etc, testing the hydrant and completing the work in all respect as per directions of the engineer in charge. (N.S.ITEM) (Safeguard/Safex/Minimax/Newage make with prior approval of Engineerin charge.

23

-

14815

... More
Providing and Fixing ISI marked RRL (IS:636 type-A) fire hose pipe 15 meter long and 63 mm dia with ISI marked (IS: 903) gun metal/stainless steel male and female coupling bound and riveted to hose pipes with copper rivets and copper wire complee as required. (N.S.ITEM) (Make: Newage / Safeguard)

46

-

8172

... More
Supply fixing testing and commissiniing of 20mm bore and 30meter long hose (high pressure rubber braided hose pipe as per IS:44) and hose reel suitable for 10 kg/sqmm operating pressure for first aid fire fighting conforming to IS:884 with 180 degree full swing Drum, fixing brackets shut off gunmetal, 40mm dia hand lever operated isolating Gun Metal Stop valve connecting directly from the riser through 40 mm dia GI pipe with sockets, elbows nipples etc including providing operating instructions on a metal plate and fixing it near hose reel complete in all respects as per drawings and directions of engineer in charge ( For Internal Hydrants). (N.S.ITEM) (Make: /Newage / Safeguard)

17

-

15158

... More
Providing gun metal/stainless steel ISI marked 63 mm dia male instantaneous pattern short branch pipes and 20mm dia. Nozzle as per IS:903 suitable for 10kg/sqmm operating pressure and suitable for interconnections to hose pipe coupling as required. (N.S.ITEM) (Make:C13Newage / Safeguard)

17

-

2834

... More
Providing and fixing standard carbon steel fireman axe with rubber insulated handled tested to 20000 volts. (N.S.ITEM)

17

-

1021

... More
Supply and installation of cast iron body 3 way 63mm dia male instantaneous inlet coupling complete with cap and chain for fire bridgade connection conforming to IS: 904 and making connectin with fire fighting pipe or under ground water tank, completing the work in all respect as per the directions of the engineer-in-charge. (N.S.ITEM) (Make: Safeguard / Safex/Minimax/Newage)

1

-

19112

... More
Providing and fixing standard fire hose cabinet suitable to fit in the 'Fire Shaft made of not less than 16 SWG MS sheet having full fronted glass hindged door (5 mm thick clear glass)including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (One coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall as required. The words :Fire Hose” to be painted on the box. ( For Internal Hydrants) Size : 2100 x 1000. (N.S.ITEM)

17

-

27020

... More
Weather proof hose cabinets fabricated from 16 g m.s. sheet with full glass door and locking arrangement, suitable to accommodate one hydrant landing valve, 2 nos. 15 m long hoses and 1-no. branch pipe. the cabinet shall be painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and shall be suitably mounted on a raised masonry platform as required. (approx. .75 m x 0.6 m x 0.3 m). the size & shape shall be subject to site conditions & prior approval. (N.S.ITEM) (For External Hydrant)

6

-

11533

... More
Providing , laying ,testing and coimmissioning of 'C' Class heavy duty M.S pipe confirming to IS 1239/ 3589 i/c fittings like elbows ,tees, flanges, tapers, nuts bolts, gasket etc, fixing the pipe on wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required for the following sizes:(N.S.ITEM)25 mm dia

736

-

660

... More
32 mm dia

127

-

829

... More
40 mm dia

50

-

941

... More
50 mm dia (DSR - 18.7.4 )

44

-

1281

... More
65 mm dia

33

-

1580

... More
80 mm dia

170

-

1910

... More
100 mm dia

301

-

2630

... More
150 mm dia

353

-

3758

... More
Providing, fixing , testing and of commissioning of Butterfly valves PN 1.6 with EPDM/Nitrile seat with nuts bolts washers, gaskets conforming to IS 13095 / BS:593 of following sizes as required for the following sizes as required :(N.S.ITEM)150 MM DIA

3

-

12184

... More
100 MM DIA

1

-

7940

... More
80 MM DIA.

23

-

6321

... More
Gun Metal Ball Valves ISI Marked screwed type tested to 20 kg/cm2 pressure ( IS-778-1984) of the following sizes: (N.S.ITEM)(a) 25 MM DIA.

19

-

1397

... More
Providing, fixing , testing and of commissioning of dual plate , non-return valve confirming to IS :5312 complete with rubber gasket , GI Bolts , nuts , washers etc as required of following sizes :(N.S.ITEM)100 MM DIA. ( DSR 2022 - 18.14.5)

1

-

11050

... More
150 MM DIA ( N.S. ITEM )

6

-

13937

... More
Supplying, Installing and Commissioning C. I. Flanged "Y" type Strainer with SS mesh,suitable flanges, nuts, bolts, gaskets etc. complete for the dia of : (N.S.ITEM)100 NB ( DSR 2022 - 18.15.2)

1

-

6664

... More
Providing and fixing Air Vessel made of 250mm dia , 8 mm thick MS Sheet , 1200 MM in height , with 25mm dia air release valve with brass isolating ball valve, flanges/union, suitable for sprinkler/wet riser/down comer system with drain arrangement with 25 mm dia Gun Metal Valve with all necessary connections complete in all respects. (N.S.ITEM)

2

-

37499

... More
Supplying, Installation,Testing & Commissioning of 15 mm dia quartzoid Bulb Type G.M. Sprinkler Head sutable to operate at 68* C complete as reqd.(UL/FM/LPC listed/Approved). (N.S.ITEM) (Make : HD Fire / TYCO)

238

-

701

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid buld type sprinklers of rating 68 degree centigrade with required accessories :Horizontal side wall sprinkler (68 degree) ( DSR 2022 - 18.21.3)

22

-

617

... More
Providing, installation, testing & commissioning of water curtain nozzle 15mm dia nickel chrome plated brass, BSPT, K-factor as per design consideration complete as required. ( DSR 2022 - 18.27)

12

-

701

... More
Supplying, installation, testing & commissioning of deluge valve (to be used for water curtains) UL listed with wet pilot basic trim assembly for DVA with test and alarm, drip and drain valve with water motor gong complete as required. ( DSR 2022 - 18.26)80mm dia. ( DSR 2022 - 18.26.2)

1

-

83435

... More
Providing, fixing, testing & commissioning of inspectors test assembly complete with test valve, sight glass sectional drain valve, union with corrosion resistant orifice all complete strictly as per drawing.50 mm dia

2

-

19771

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required. (DSR -2018 (E & M ) DSR - 16.8)

19

-

1094

... More
Providing & fixing flow switch in following size M.S pipe including connection etc as required . ( DSR 2022 - 18.23)150mm dia ( DSR 2022 - 18.23.1)

2

-

9021

... More
PORTABLE FIRE EXTIGUSHERS: Fire extinguishers ABC dry powder 6Kg capacity. (Make: Minimax / Safex / SAFEGUARD)

17

-

3097

... More
H2O / Co2 9 Ltr Capacity (Make: Minimax / Safex / SAFEGUARD)

8

-

2768

... More
Co2 4.5Kg Capacity (Make: Minimax / Safex / SAFEGUARD)

17

-

7467

... More
Supply & fixing of MS round bottom fire buckets of 9 liters capacity filled with sand including proper supporting/hanging arrangements in MS fabrication painted by fire red color over two coats of primer complete in all respects as per the directions of engineer in charge.

2

-

2405

... More
Providing & fixing of photoluminescent, non toxic, non-radio active, maintenance free self glowing, exit signs of over all size 300 mm x 150 mm with aluminimum sheet (3 mm thick) and mounting arrangement for wall/ceiling mounting. the colour combination and size of the letters shall be as per is:12349 amended upto date.(a) SINGLE SIDED EXIT SIGNS

21

-

4284

... More
(b) DOUBLE SIDED EXIT SIGNS

2

-

5140

... More
HVAC WORKS:VRV / VRF SYSTEM: Supply, installation, testing and commissioning of variable refrigerant volume/flow modular type air-conditioning system suitable for cooling/heating by scroll/rotory compressor controlled by individual inverter complete with indoor & outdoor units with individual wired and wireless remote controller for indoor units & centralized controller, interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, control cabling & fittings etc. as per details given in specifications and having following items. The ODUs shall be suitable for 3 phase, 4 wire system, 415V+10%, 50Hz, AC supply and indoor shall be suitable for single phase 220-240V, 50 Hz AC supply.OUTDOOR UNITS: Supply, installation, testing & commissioning of modular type VRF/ VRV air-cooled Outdoor units suitable for cooling / heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R410A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V+/-10%, 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. - The COP at AHRI conditions shall not be less than 3.6 & IEER not less than 6.5. - Unit shall include support stand with two coat of enmel panint as per specification. - Offered ODU model shall be with highest possible COP by OEM. - Vendor to indicate COP at 100% load & at part loads i.e. 75 & 50% in the data sheets/shop drawings:48 HP

1

-

1660325

1

-

1297056

1

-

1224997

2

-

1067435

1

-

998390

1

-

821380

1

-

434490

... More
CEILING MOUNTED CASSETTE UNITS: Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.3.19 TR

1

-

50482

... More
2.56 TR

4

-

48023

... More
2.0 TR

18

-

45417

... More
1.59 TR

42

-

45195

... More
1.28 TR

33

-

43796

... More
1.0 TR

46

-

42291

... More
CENTRALISED REMOTE CONTROLLER (CRC): Supply, installation, testing & commissioning PC compatible main intelligent touch screen Centralised Remote Controller (CRC) including all the hardware, accessories etc. suitable to operate, monitor, on/off, temperature setting etc. for the entire Indoor and Outdoor equipment configuration for above VRF systems with spare minimum 10 no. IDUs & 3 no. ODUs. CRC shall be compatible on BACnet / Modbus BMS protocol. As per specification / drawings and as directed by Engineer In Charge. Functions of central controller shall be able to perform following functions: a) Control of all the ODUs & IDUs with monitoring of vital parameters such as temperature sensing & setting, ON/OFF, status etc. b) Permit / prohibit function of each remote-control unit. c) Operation of units in individually or in group. d) Display of floor plans to enable quick search of desired units. e) Filter status of indoor units with alarm. f) Operation history of units. g) Fault indication with Alarm. h) Energy management through monitoring the energy consumption data and identifying inefficient operations.

1

-

254934

... More
REFERIGERANT COPPER PIPING: Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

229

-

842

... More
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

590

-

907

... More
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

229

-

1046

... More
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

220

-

1335

... More
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

290

-

1441

... More
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

85

-

1762

... More
25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

45

-

1836

... More
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

80

-

1900

... More
31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

80

-

1986

... More
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

15

-

2266

... More
38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

70

-

2408

... More
41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation *Note: 1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by : (i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (3) The makes of tube fittings shall be same as that of tubes. (4) The thickness of fittings used shall be same as that of the pipe. (5) All insulation joints must be covered with EPDM Rubber Tape.

225

-

2574

... More
Supply & fixing of mechanical + UV protective coating for exposed copper piping insulation with 1 layer of glass cloth and UV paint. The covering shall be provided with min 6-7 mil thickness and 200 gram/sqmt (±10%) interwoven glass fabric.

50

-

4508

... More
Supply, installation, testing & commissioning of Ref Nut/Y-joints brass for indoor and outdoor units of suitable size as per requirement. As per specification / drawings and as directed by Engineer In Charge.

130

-

6880

... More
Supply and laying, testing & commissioning of 2Cx1.5 Sq.mm Copper conductor control cables through PVC conduit on existing tray including fixing clamps & proper connections to equipments etc. complete as required. As per specification/drawings and as directed by Engineer In Charge.

1070

-

457

... More
Supply, installation, testing & commissioning of perforated GI (Hot Dip Galvanised) Cable Trays made of 2mm thick GI sheet of size 125 x 300 x 125 mm with suitable GI sheet cover made of 2 mm thick for refrigerant piping at terrace / exposed. The covers shall be fitted on the cable tray with self tapping screw on both sides. The cable tray shall be installed on suitable MS angle/channel support.

45

-

1483

... More
HI-WALL SPLIT AC UNITS (COOLING ONLY TYPE): Supply, Installation, testing and commissioning of following capacity Hi Wall type split air-conditioning unit suitable to operate between 180-260 volt, 50 Hz, 1 phase power supply, with air-cooled evaporator with coil, fan, and fan motor, air-cooled condenser with hermetically sealed Inverter compressor (with R-410a/R-32/R-407c/R-134a), condenser coil, propeller fans controls, control panel, including control wiring, cordless remote, Necessary supporting arrangement for indoor unit, M.S. frame duly Powder Coated/ Epoxy painted as per approved shade by architect to locate Outdoor Unit with necessary vibration isolation arrangement as per site condition etc. The Unit should be 5 Star rated (on the date of procurements, the minimum EER value of the units should be as per ECBC-2017). The Outdoor unit Compressor must be provided with 5 Year Warranty Period. The Refrigerant pipe size and gas quantity should suit to the copper pipe length at actual. The provided unit should have inbuilt automatic voltage stabilizer with time delay relay. The unit shall be complete with prefilters section, control panel, with suitable rating of MCB/DP. As per specification/ drawings and as directed by Engineer-in-charge.Notes: a) Civil Work such as wall hole making, wall chisling, refilling of chiseling part with mortar etc as per site condition. b) Nitrogen pressure testing for leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts.2.0 TR Nominal Capacity

2

-

80576

... More
DRAIN PIPING: Providing and fixing of Hard CPVC drain water piping with fittings, support and insulated with 6mm thick closed cell elastomeric nitrile rubber insulation complete as per specifications. As per specification / drawings and as directed by Engineer In Charge.65 mm dia

50

-

415

... More
50 mm dia

75

-

380

... More
40 mm dia

95

-

332

... More
32 mm dia

185

-

297

... More
25 mm dia

550

-

249

... More
CABINET TYPE CENTRIFUGAL FANS FOR TOILET EXHAUST: Supply, installation, testing & commissioning of Cabinet type Centrifugal Fans for Exhaust Air System complete with double skin construction fabricated out of extruded aluminium sections with 0.63 mm thick pre-plasticised GI sheet on outside and 0.63 mm thick plane GI sheet inside with 25 mm thick insulation, minimum 32 Kg/m3 density PUF/ Glasswool insulation in between them by injection moulding machine. The unit shall be complete with belt driven DIDW forward/backward curved design blower, fan assembly (cabinet as well as fan, combined unit) shall be AMCA certified (AMCA certification required for Air Performance & Sound) & totally enclosed, fan-cooled, provided with class F insulation, and of approved make, Unit shall have MS channel base, housing, V-belt drive comprising of fan & motor pulleys and one set of belts, slide rails, fire retardant flexible connection with nut bolts at outlet, vibration isolators & bird screen required for complete installation.Fan shall be provided with TEFC Sq.cage, 'F' Class induction motor with minimum IE-3 rating suitable for 415V±10%, 50 Hz, 3 phase electric supply. outlet velocity shall be less than 2000 FPM (10.2 m/s). The Fan must be selected for minimum power consuption & maximum efficiancy at respective duty point. Max. noise level shall be 75 dBA at 3 meter in hemispherical reverberant room condition. Fan shall conform to AMCA standard 211 and 311. Fan must be tested in accordance with ANSI/AMCA standard 210-99 and AMCA standard 300-96 in an AMCA accredited laboratory. Fans shall be certified to bear the AMCA label for air and sound and FEI / FEG performance. All fans must be listed in AMCA website. Fan housing shall be made of galvanised steel sheet with min. 220 GSM zinc coating. Fan wheel and housing shall be statically and dynamically balanced to the AMCA 2.5 standard. The motor and impeller speed shall be as per OEM standard and capacities shall be as follows.9800 CFM, 35mm WG

1

-

393142

... More
INLINE FANS: Supply, installation, testing & commissioning of following capacities of ducted inline fan with AMCA certified (AMCA certification requird for Air Performance & Sound) as per specification and complete with suitable single/ 3 phase Motor, bird screen. etc. and required for complete installation comprising of the following and complete as per specification/ drawings and as directed by Engineer In Charge. The motor shall be suitable for 220/ 415±10% volt single/ 3 phase 50 cycles AC supply. Quoted price shall be inclusive of electronic speed regulator and wiring between fan & speed regulator for single phase fans. Incase of 3 phase fans quoted price shall be inclusive of DOL starter panel with cabling between starter panel and fan. The incoming power supply to speed regulator/ starter panel shall be provided seperately.The fan must be selected for minimum power consuption & maximum efficiency at respective duty point. The fan casing shall be made of galvanised steel casing with min. 200 GSM zinc coating. Max. noise level shall be 55 dBA at 3.0 meter. To acheive the desired sound level fan casing can be double skinned with 0.63 mm thick pre-plasticised GI sheet on outside and 0.63 mm thick plane GI sheet inside with PUF/ mineral wool/ glass wool insulation in between. However; If OEM is not able to meet 55 dBA at 3 meter for any specific case, 60 dBA at 3 meter sound level can be accepted subject to detail technical justifications from Vendor/OEM."2800 CFM, 25mm WG

1

-

146546

... More
1625 CFM, 25mm WG

1

-

110844

... More
1200 CFM, 25mm WG

2

-

100003

... More
700 CFM, 25mm WG

1

-

90086

... More
725 CFM, 25mm WG

1

-

90086

... More
600 CFM, 25mm WG

1

-

84519

... More
300 CFM, 15mm WG

1

-

56483

... More
100 CFM, 15mm WG

4

-

56483

... More
PROPELLER FAN: Supply, installation, testing & commissioning of direct driven PROPELLER FANS for exhaust air as shown in drawings. Each fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate, accessories like wire guard, bird screen and fixed louvers for weather protection as required. The Motor shall be suitable to run on 1 Phase /50 Hz /220 V electrical power. Fan speed should not more than 1400 RPM. Only for 100 cfm fan maximum speed 2900 RPM shall be accepted. Note: Propeller fans for toilets shall be PVC type & for other areas metallic type fan shall be provided.Suitable Dia Fan for 1200 CFM

2

-

32520

... More
Suitable Dia Fan for 1000 CFM

1

-

28091

... More
Suitable Dia Fan for 200 CFM for Toilet Exhaust

4

-

16744

... More
Suitable Dia Fan for 100 CFM for Toilet Exhaust

3

-

4151

... More
AXIAL FLOW FANS FOR EXHAUST AIR (NORMAL & FIRE MODE): Supplying, installation, testing and commissioning of ceiling hung / floor mounted exhaust air long casing Axial Flow Fans (motor should completly accomodated inside the fan casing). The axial fans shall be AMCA certified for air, sound performance and FEG. Same model / series / pitch angle should be listed on AMCA website. Interpolation shall not be acceptable. Axial fans of following capacity with GSS / MS powder coated or epoxy coated casing (in case of GSS casing, the fans should be synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating) with aluminium alloy impellers with high efficiency aero-foil designed blades, impeller directly driven by TEFC induction motor of efficiency class IE3 for normal mode fans & IE2 for fire mode fans, suitable for 415±10% volts, 50 HZ, 3 phase AC supply and thermally rated for 250 deg C for 2 hours Class 'H' insulation. Thickness of the casing shall not be less than: For Dia (300 to 650) mm – 2mm, Dia (700 to 1140) mm – 3 mm, Dia (1200 to 1400) mm – 4mm & Dia 1600 – 5 mm.Complete fan assembly & motor should be able to withstand and operate at a temperature of 250 deg C for 2 hours as per BSEN-12101-3/2015 and should be CE cerified / UL labeled. The make of the motor should be same which has been used during the testing of the fans in the laboratory also mentioned in fire reports. Fan shall be complete with fire retardant canvas connection at inlet & outlet, back draft dampers at fan outlet (wherever more than one fan will be connected with common plenum / shaft), Mounting clits for ceiling suspension, Inlet Screen, Grouting Frame, Spring hanger including foundation as required and all accessories complete as required and as per specifications. Back draft dampers (BDD) blades shall be able to withstand 15.2 m/s free area velocity and opening pressure shall not be more than 50 Pa. BDD frame shall be constructed out of next heavier gauge GSS from the duct gauge on which it will be installed. Fans shall be activated from fire signal from fire alarm system (manual operation shall also possible). Air moving capacity shall be as follows: Fan Selection Parameters & Notes: a) Normal mode fans shall be selected for maximum efficiency & minimum sound level. Efficiency of normal mode fans should not less than 70%. Efficiency of fire mode fans should not less than 60%. b) Normal mode fans should be selected to achieve maximum 75 dba sound level at a distance of 3 mtrs from the fan. Sound level of smoke sxtraction fans (fire mode fans) shall be maximum 85 dba at a distance of 3 mtrs from the fan. c) Outlet velocity of fans should not exceed 12.2 m/s for normal mode fans & 15.2 m/s for fire mode fans. d) Fans shall be selected for maximum 1450 RPM. e) Vendor has to proposed same model / series / pitch angle, which is certified by AMCA and listed on AMCA website. Interpolation shall not be acceptable.15,000 CFM, 35mmWG, for Basement Parking Zone-1 Exhaust (Normal & Fire Mode)

2

-

357406

... More
10,500 CFM, 35mmWG, for Basement Parking Zone-2 Exhaust (Normal & Fire Mode)

2

-

270826

... More
3000 CFM, 15mmWG, for Electrical Room Exhaust (Normal & Fire Mode)

1

-

91694

... More
42,500 CFM, 30mmWG, for Ground to 6th floor Common Area Smoke Exhaust (Fire Mode)

2

-

680924

... More
AXIAL FLOW FANS FOR SUPPLY AIR (FIRE MODE): Supplying, installation, testing and commissioning of ceiling hung / floor mounted supply air long casing Axial Flow Fans (motor should completly accomodated inside the fan casing). The axial fans shall be AMCA certified for air, sound performance and FEG. Same model / series / pitch angle should be listed on AMCA website. Interpolation shall not be acceptable. Axial fans of following capacity with GSS / MS powder coated or epoxy coated casing (in case of GSS casing, the fans should be synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating) with aluminium alloy impellers with high efficiency aero-foil designed blades, impeller directly driven by TEFC induction motor of efficiency class IE2, suitable for 415±10% volts, 50 HZ, 3 phase AC supply with Class 'F' insulation. Thickness of the casing shall not be less than: For Dia (300 to 650) mm – 2mm, Dia (700 to 1140) mm – 3 mm, Dia (1200 to 1400) mm – 4mm & Dia 1600 – 5 mm.Fan shall be complete with weather protection canopy, fire retardant canvas connection at inlet & outlet as required, back draft dampers at fan outlet (wherever more than one fan will be connected with common plenum / shaft), Mounting clits for ceiling suspension, Inlet Screen, Grouting Frame, Spring hanger including foundation as required and all accessories complete as required and as per specifications. Back draft dampers (BDD) blades shall be able to withstand 15.2 m/s free area velocity and opening pressure shall not be more than 50 Pa. BDD frame shall be constructed out of next heavier gauge GSS from the duct gauge on which it will be installed. Fans shall be activated from fire signal from fire alarm system (manual operation shall also possible). Air moving capacity shall be as follows: Fan Selection Parameters & Notes: a) Fans shall be selected for maximum efficiency & minimum sound level. Efficiency should not less than 60%. b) Sound level of fans shall be maximum 85 dba at a distance of 3 mtrs from the fan. c) Outlet velocity of fans should not exceed 15.2 m/s. d) Fans shall be selected for maximum 1450 RPM. e) Vendor has to proposed same model / series / pitch angle, which is certified by AMCA and listed on AMCA website. Interpolation shall not be acceptable.42,500 CFM, 30mmWG, for Ground to 6th floor Common Area Supply Air (Fire Mode)

2

-

579927

... More
12,500 CFM, 25mmWG, for Staircase Pressurisation (Fire Mode)

1

-

172586

... More
12,000 CFM, 25mmWG, for Lift Lobby Pressurisation (Fire Mode)

1

-

172586

... More
8,000 CFM, 20mmWG, for Lift Wells Pressurisation (Fire Mode)

2

-

118549

... More
AIR-DISTRIBUTION WORKS: Supply, Fabrication, installation and testing of sheet metal ducts (FACTORY FABRICATED DUCTS) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods, anchor bolts, GI bolts & nuts, canvas connections, duct dampers & splitter dampers etc., and as required by the specifications. All size duct should be with ductmate joints. No C & Ss clip joints should be used. 24 gauge ducting

995

-

1384

... More
22 gauge ducting

380

-

1549

... More
20 gauge ducting

231

-

1779

... More
18 gauge ducting

22

-

1977

... More
Volume Control Dampers:Supply, installation, testing and balancing of Volume Control Dampers with operating handle for duct branches in accordance with the approved shop drawings and specifications.

37

-

8436

... More
Aluminium Grilles: Powder coated extruded Aluminum Grilles with end flanges, and required cut to size as per approved drawings and specifications. Grille should be fixed with opposed blade aluminum collar damper.Supply Air, Pressurisation Air & Toilet Exhaust Air Grilles with collar damper.

31

-

12521

... More
Exhaust Air Grille without collar damper.

9

-

8956

... More
LOUVERS: Supply, installation, testing and balancing of Extruded Al. powder coated Rain Protection louvers with both side flange for Air intake and Exhaust as per specification & approved shop drawing.Louvers for Fresh Air with filter box & MERV-8 Pre-filters

4

-

21559

... More
Louvers without filter box

9

-

10754

... More
CANVASS CONNECTIONS: Supply, installation and balancing of Single Layer Insulated 70 /100 MM WIDE Canvass Connection

2

-

3361

... More
MCC-01-Ventilation Fans-Basement; located @ basement near Vent fans: Supply, erection, testing and commissioning of wall/ Floor mounted control panel made out of 16 G MS sheet metal duly powder coated and comprising combination fuse switch units, incoming MCCBs, Indicators, Ammeter, Volt meter, CTs, cable alleys, connecting strips with lugs and ferruls, internal copper control wiring panel signage and Tagged etc. complete hinged doors with gaskets etc., all assembled on as per design and specifications as per below data: Incoming MCCB-100A-1#, Outgoing MPCBs, star delta motor starter with OLR, timer, indicators, Ammeter, CTs suitable 5.5KW axial flow fans-3 nos and MPCBs, DOL starter with OLR, timer, indicators, Ammeter, CTs suitable 4.0KW axial flow fans-3 nos. Automatic timer controller to be attached with the starter panel for Basement ventilation exhaust fans for Auto timer peration of the ventilation fans as per designed usage and requirement in 24 hour format. Outgoing MPCBs, DOL motor starter with OLR, timer, indicators, Ammeter, CTs suitable 1.0KW-5.5KW axial flow fans/exhaust fans-6 Sets.

1

-

480183

... More
VRF Panel-1 (Outdoor Type) : Incoming - 1 Set of 400 Amps. 415 Volts, FP MCCB of 36 KA with overload, O/V, O/C and earth fault protection. Bus bars: 1 Set of 500-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). Metering & Indication: One set of R/Y/B phase indication Lamp & MCB. 1 No. Multi Function Meters (A/V/kW/kWh).ON/OFF/TRIP indication lamp for incomer. Outgoing: 1 Nos. 100 Amp 4P RCBO of 25 KA. 4 Nos. 100 Amp 4P RCBO of 25 KA. Panel as mentioned above should be complete in all respect with internal wiring, al. bus bar etc. (NS ITEM)

1

-

141149

... More
VRF Panel-1 (Outdoor Type) : Incoming - 1 Set of 250 Amps. 415 Volts, FP MCCB of 36 KA with overload, O/V, O/C and earth fault protection. Bus bars: 1 Set of 300-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). Metering & Indication: One set of R/Y/B phase indication Lamp & MCB. 1 No. Multi Function Meters (A/V/kW/kWh).ON/OFF/TRIP indication lamp for incomer. Outgoing: 5 Nos. 63 Amp 4P RCBO of 25 KA. Panel as mentioned above should be complete in all respect with internal wiring, al. bus bar etc. (NS ITEM)

1

-

141149

... More
Pressurisation Fans Panel - Terrace (Outdoor Type); located @ Terrace fans: Supply, erection, testing and commissioning of wall/ Floor mounted control panel made out of 16 G MS sheet metal duly powder coated and comprising combination fuse switch units, incoming MCCBs, Indicators, Ammeter, Volt meter, CTs, cable alleys, connecting strips with lugs and ferruls, internal copper control wiring panel signage and Tagged etc. complete hinged doors with gaskets etc., all assembled on as per design and specifications as per below data: Incoming MCCB-160A-1#, Outgoing MPCBs, star delta motor starter with OLR, timer, indicators, Ammeter, CTs suitable 15.0KW axial flow fans-5 Nos and MPCBs, DOL starter with OLR, timer, indicators, Ammeter, CTs suitable 2.2KW axial flow fans-5 nos. Automatic timer controller to be attached with the starter panel for Basement ventilation exhaust fans for Auto timer peration of the ventilation fans as per designed usage and requirement in 24 hour format. Outgoing MPCBs, DOL motor starter with OLR, timer, indicators, Ammeter, CTs suitable 1.0KW-15.0KW axial flow fans/exhaust fans-10 Sets.

1

-

898095

... More
Incoming -cum out going :One (1) Set phase indication lamps with control SP MCB.One (1) Set Digital Ammeter wih CTs of suitable range and selector switch.One (1) Digital Voltmeter selector switch with control SP MCB.One (1) Set of ON/OFF/Trip indication lampsOne (1) No. 25A, 10 KA, TP+N MPCB with DOL Starter suitable for 4.0 kW motor complete with AC3 duty power contactor, thermal O/L Relay, single phasing preventer, ON-OFF and Trip Indicating lamps, Start/ Stop push bottons Selector Switch for Local/ OFF/ Remote etc. Starter Panel as described above

1

-

33212

... More
Incoming -cum out going :One (1) Set phase indication lamps with control SP MCB.One (1) Set Digital Ammeter wih CTs of suitable range and selector switch.One (1) Digital Voltmeter selector switch with control SP MCB.One (1) Set of ON/OFF/Trip indication lampsOne (1) No. 16A, 10 KA, TP+N MPCB with DOL Starter suitable for 0.55 kW motor complete with AC3 duty power contactor, thermal O/L Relay, single phasing preventer, ON-OFF and Trip Indicating lamps, Start/ Stop push bottons Selector Switch for Local/ OFF/ Remote etc. Starter Panel as described above

1

-

31828

... More
L.T. CABLES SUPPLY (POLYCAB/KEI/RR KABEL: Supply, Laying, installation testing and commissioning of the following 1100 Volts Al/ Cu. Conductor, PVC insulated PVC sheathed, steel armoured/ unarmoured or XLPE cables as per IS-1554/ 7098 Part- I and as per standard specification (NS ITEM)3.5 core 50 sq.mm AL. XLPE ARM CABLE

50

-

463

... More
3.5 core 35 sq.mm AL. XLPE ARM CABLE

50

-

344

... More
4 core 4 sq.mm CU. XLPE ARM CABLE

200

-

344

... More
4 core 6 sq.mm CU. XLPE ARM CABLE

50

-

443

... More
4 core 10 sq.mm CU. XLPE ARM CABLE

50

-

705

... More
Supply of Fire Survival armoured cables of 600/ 1000V rated with Copper circular conductor having glass mica fire barrier tape covered by an extruded layer of XLPE GP 8 insulation and LSZH inner & outer sheath. Generally as per BS 7846, IEC-60502-1 & BS-8519 (latest edition). Should retain circuit integrity as per BS 8491:2008 (120 mins) for cables having overall dia of 20mm and above. Cables with overall dia below 20 mm should retain circuit integrity as per BS 8434-2. Cable shall be manufactured as per TUV/ BRE/ LPCB certification.4 core 4 sq.mm CU. XLPE FS ARM CABLE

240

-

569

... More
4 core 6 sq.mm CU. XLPE FS ARM CABLE

240

-

809

... More
Cable Trays : Supply and erection of 1.6 mm thick slotted type, hot dip galvanized, cable trays and cable tray supports out of rolled Sheet, sections, pipes, plates, etc. including welding, anchorbolts, threaded down rods, bolting, riveting, supply of necessary anchor bolts and grouting etc. including breaking walls, floors, etc. for structures as required including supply of all GI hardware materials, all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-charge. The rate shall include supply & fixing of MS Grip bolts in columns/ beams/ walls/ ceiling etc.as required & including drilling. Rod supports shall be of galvanized full threaded rods of sizes 8,10 & 12mm dia for fixing to anchor fastener, anchor bolts etc. For the purposes of quoting rate per meter Contractor to include the cost of all the above. No separate measurement or payment will be considered.150 mm wide x 50 mm high

50

-

995

... More
Supply & Installation of GI wires for earthing and to be run with the power cable.8 SWG GI wire.

150

-

65

... More
Supply, Installation of MS support for Fans/ Ducts etc duly cut to length, painted with primer and paint as approved by Engineer-in-charge

20

-

1588



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.