Gurugram Metropolitan Development Authority Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Gurugram Metropolitan Development Authority - GMDA Tender

Works
Eprocure
Opening Date27 Oct 2023
Closing Date18 Oct 2023
Tender Amount₹ 26,44,65,518 
Notes
Download

Costs

  • EMD

    ₹ 52,89,311
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Repair of accessories, repair / leakage in pipe line, repair of sluice valve/ non return valve, repair/replacement of specials, electrical and mechanical components etc. at the premises of the each / every installation within its boundary wall of all units i.e. inside or outside of any pump house and filteration units/annexue

36

-

-

... More
Supply and feeding of PAC (Poly Aluminium Chloride) liquid of Medium Basicity including carriage loading, unloading and stacking in the Store at WTP Basai, Gurugram .

4796.82

-

-

... More
Supply and feeding of liquid Chlorine Gas using 900 Kg tonner (empty tonner returnable basis) with existing chlorination plant including repair of plant all spares like chlorine valve, pressure valve, safety mask, lead washer, copper tube, testing kit and repairing of chlorination system at WTP Basai, Gurugram as per required parameters for pre as well as post chlorination complete in all respect and as per complete satisfaction of Engineer in Charge/ as per DNIT specification.

884.52

-

-

... More
Repair and maintenance of Transformers, including dehydration and filling up of transformer oil etc. as per requirement as well as as per guildlines of CEI, HT/LT installations, DG sets, VCBs, ACB, Conductor, XPLE cable, GO Switch, electric poles, insulators etc. including DHBVN Meter/CT-PT/Meter Box to all three units of WTP, Electrical fittings such as mast light, Electrical fans, Flood light, tube light etc. within boundary of water works complete in all respect as per DNIT Specifications.....

36

-

-

... More
Supply of consumable chemicals such as hydrochloric acid, sulfuric acid, sodium hydroxide, and other strong acids and alkalis and other consumable item required testing for bectrological and chemicals for testing of raw water and clear water at existing water testing laboratory, updation of record offline as well as online as per DNIT....

36

-

-

... More
Providing and Fixing of MS flat ring/clamp of size 75x8 mm around the pipe of water supply line of different size for repair of leakage of pipeline as per the site requirement including rivets, screws, nuts and bolts, washer and rubber sheet for packing etc. complete in all respect and as per satisfaction of Engineer in charge. MS Flat - 75x8mm Size Rubber sheet – 10mm thick x 250mm width Nuts and bolt of dia 12 mm and 300 mm minimum length II.       For 700 mm to 800mm i/d pipe line....

12

-

-

... More
Providing and Fixing of MS flat ring/clamp of size 75x8 mm around the pipe of water supply line of different size for repair of leakage of pipeline as per the site requirement including rivets, screws, nuts and bolts, washer and rubber sheet for packing etc. complete in all respect and as per satisfaction of Engineer in charge. MS Flat - 75x8mm Size Rubber sheet – 10mm thick x 250mm width Nuts and bolt of dia 12 mm and 300 mm minimum length III.      For 900 mm i/d pipe line....

12

-

-

... More
Providing and Fixing of MS flat ring/clamp of size 75x8 mm around the pipe of water supply line of different size for repair of leakage of pipeline as per the site requirement including rivets, screws, nuts and bolts, washer and rubber sheet for packing etc. complete in all respect and as per satisfaction of Engineer in charge. MS Flat - 75x8mm Size Rubber sheet – 10mm thick x 250mm width Nuts and bolt of dia 12 mm and 300 mm minimum length IV.     For 1000 mm to 1200mm i/d pipe line.....

12

-

-

... More
Providing and Fixing of MS flat ring/clamp of size 300x10mm around the pipe of water supply line of different size for repair of leakage of pipeline as per the site requirement including rivets, screws, nuts and bolts, washer and rubber sheet for packing etc. complete in all respect and as per satisfaction of Engineer in charge. MS Flat - 300x10 mm Size Rubber sheet – 10mm thick x 400mm width Nuts and bolt of dia 12 mm and 300 mm minimum length I.         For 300 mm to 600mm i/d pipe line....

12

-

-

... More
Providing and Fixing of MS flat ring/clamp of size 300x10mm around the pipe of water supply line of different size for repair of leakage of pipeline as per the site requirement including rivets, screws, nuts and bolts, washer and rubber sheet for packing etc. complete in all respect and as per satisfaction of Engineer in charge. MS Flat - 300x10 mm Size Rubber sheet – 10mm thick x 400mm width Nuts and bolt of dia 12 mm and 300 mm minimum length II.       For 700 mm to 800mm i/d pipe line....

12

-

-

... More
Providing and Fixing of MS flat ring/clamp of size 300x10mm around the pipe of water supply line of different size for repair of leakage of pipeline as per the site requirement including rivets, screws, nuts and bolts, washer and rubber sheet for packing etc. complete in all respect and as per satisfaction of Engineer in charge. MS Flat - 300x10 mm Size Rubber sheet – 10mm thick x 400mm width Nuts and bolt of dia 12 mm and 300 mm minimum length III.      For 900 mm i/d pipe line.....

12

-

-

... More
Providing and Fixing of MS flat ring/clamp of size 300x10mm around the pipe of water supply line of different size for repair of leakage of pipeline as per the site requirement including rivets, screws, nuts and bolts, washer and rubber sheet for packing etc. complete in all respect and as per satisfaction of Engineer in charge. MS Flat - 300x10 mm Size Rubber sheet – 10mm thick x 400mm width.... Nuts and bolt of dia 12 mm and 300 mm minimum length IV.     For 1000 mm to 1200 mm i/d pipe line

12

-

-

... More
Repairing of leakaged joints of MS pipe by welding in existing running line including excavation of earth dewatering/bailing out pipe line water, execution of work and all other TandP required complete in all respect as per satisfaction of the Engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him. II.         For 1000 mm to 1100 mm i/d pipe line....

12

-

-

... More
Repairing of leakaged joints of MS pipe by welding in existing running line including excavation of earth dewatering/bailing out pipe line water, execution of work and all other TandP required complete in all respect as per satisfaction of the Engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him. IV.      For 1300 mm i/d pipe line

12

-

-

... More
Repairing of leakage of burst CI/ DI pipe line with new Pipe (pipe to be Supplied by Dept.) by fixing mechanical joint collar as per IS Standared including excavation of earth dewatering/bailing out pipe line water, execution of work and all other TandP complete in all respect as per satisfaction of the Engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him. II.         For 200mm to 250 mm i/d pipe line....

8

-

-

... More
Repairing of leakage of burst CI/ DI pipe line with new Pipe (pipe to be Supplied by Dept.) by fixing mechanical joint collar as per IS Standared including excavation of earth dewatering/bailing out pipe line water, execution of work and all other TandP complete in all respect as per satisfaction of the Engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him. II.         For 300mm to 500 mm i/d pipe line.....

8

-

-

... More
Repairing of leakage of burst CI/ DI pipe line with new Pipe (pipe to be Supplied by Dept.) by fixing mechanical joint collar as per IS Standared including excavation of earth dewatering/bailing out pipe line water, execution of work and all other TandP complete in all respect as per satisfaction of the Engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him. III.       For 600 mm i/d pipe line....

8

-

-

... More
Repairing of leakage of burst CI/ DI pipe line with new Pipe (pipe to be Supplied by Dept.) by fixing mechanical joint collar as per IS Standared including excavation of earth dewatering/bailing out pipe line water, execution of work and all other TandP complete in all respect as per satisfaction of the Engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him. IV.      For 700 mm i/d pipe line....

8

-

-

... More
Repairing of leakage of burst CI/ DI pipe line with new Pipe (pipe to be Supplied by Dept.) by fixing mechanical joint collar as per IS Standared including excavation of earth dewatering/bailing out pipe line water, execution of work and all other TandP complete in all respect as per satisfaction of the Engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him. VI.       For 900 mm i/d pipe line....

7

-

-

... More
Supplying and placing of pig lead in melted form into leakagedsocketted joints and its caulking so as to tighten the joint in CI/DI pipeline of any size.....

5000

-

-

... More
Disconnection of illegal connections of defaulters providing labour, socket pipe, JCB/Hydra, dewatering pump etc. in Gurugram complete in all respect as per satisfaction of Engineer in charge and all other works contingent thereto......

125

-

-

... More
Dismantling of existing old sluice valve and supply, installing, testing and commissioning of new sluice valve in existing Filteration unit 1 including cost of carriage, loading, unloading of DI double flanged, gear machanised, resilient seated, non-gland, non-rising sluice valve of rating PN 1.0 including fixing of control rod and compatible with actuater complete in all respect as per site requirement of make IVC Nasik/VAG/AVK/Talis/JASH The rates should be quoted by the agency considering the rebate of old dismantled material. 300mm dia .....

12

-

-

... More
Dismantling of existing old sluice gate and supply, installing, testing and commissioning new sluice gate as per IS 13349 Thimble Mounted OR AWWA C501 including Heavy Duty Gear Box and 4 mtr. Rising spindle type with Spindle SS 410 with grouting Brackets, Headstock, compatible with actuater and operating arrangement in back wash outlet channel for Filteration unit No. 1 at WTP Basai size 500mm x 500mm make IVC Nasik/VAG/AVK/Talis/JASH and all works contingent thereto.” The rates should be quoted by the agency considering the rebate of old dismantled material.

6

-

-

... More
Dismantling of existing old sluice gate andSupply and Commissioning of single faced sluice gate IS: 3042 CI manually opereated sluice gate rising spindle type, generally conforming to IS 210GR.FG200 framed with spigot cast back and door fitted with gun metal sheeting faces, complete SS spindle and extension spindle, CI Guide bracket SS coupling, compatible with actuater and CI head stock for Filteration unit No. 1 at WTP Basai size 600mm x 600mm make IVC Nasik/VAG/AVK/Talis/JASH and all works contingent thereto.” The rates should be quoted by the agency considering the rebate of old dismantled material. ....

6

-

-

... More
Dismantling of existing old sluice gate and supply, installing, testing and commissioning new sluice gate as per IS 13349 Thimble Mounted OR AWWA C501 including Heavy Duty Gear Box and 4 mtr. Rising spindle type with Spindle SS 410 with grouting Brackets, compatible with actuater Headstock and operating arrangement in back wash outlet channel for Filteration unit No. 1 at WTP Basai size 750mm x 1000mm make IVC Nasik/VAG/AVK/Talis/JASH and all works contingent thereto.” The rates should be quoted by the agency considering the rebate of old dismantled material. ....

2

-

-

... More
Providing and Fixing of Complete Rotating assembly for Kirloskar make Model SCT 350-66 . RPM 960 Rated flow/Pressure 1332 m^3/Hr/65 Mtr Head. Pump set No. 3,CWPH 2 The rates should be quoted by the agency considering the rebate of old dismantled material. ....

1

-

-

... More
Providing and Fixing of Complete Rotating assembly for Wilo MandP make Model 400/500 AST having serial no. 81211885/10/1. The assembly shall comprises of impeller(LG-2),Neck ring (BB), Shaft with sleeve and Nut (SS-410) and Logging Ring, Gland and Bearing covers (C I), with suitable bearings in fitted condition, rest of other parts as per MandP standards. Make Pump set No. 7,RWPH 2 The rates should be quoted by the agency considering the rebate of old dismantled material. ....

1

-

-

... More
Replacement, taking out of 600 mm NRV from pump house providing and fixing in existing delivery pipe line of pump sets including cost of carriage, loading, unloading of make IVC Nasik/VAG/AVK/Talis/JASH only of PN 1.0 rating at WTP, Basai, Gurugram complete and all other works contingent thereto under OandM master water supply of maintenance of distribution line. pump set-8, At RWPH 1 The rates should be quoted by the agency considering the rebate of old dismantled material. ....

1

-

-

... More
Providing and fixing in existing delivery pipe line of pump sets including cost of carriage, loading, unloading of make IVC Nasik/VAG/AVK/Talis/JASH only of PN 1.0 rating at WTP, Basai, Gurugram complete and all other works contingent thereto under OandM master water supply of maintenance of distribution line. For 2 New installation , At RWPH 1 For 600mm i/d NRV .....

2

-

-

... More
Supply, installing, testing and commissioning ofglandless with bush mechanism new sluice valve in existing systemincluding cost of carriage, loading, unloading of DI double flanged gear mechanised resilient seated non gland, non rising sluive vlave of rating PN 1.0 including with provision of electric Actuator with integral starter etc. fixing of control rod in all respect as per site requirement of make IVC Nasik/VAG/AVK/Talis/JASH For 600 mm i/d Sluice valve For 2 New installation,At RWPH 1....

4

-

-

... More
Construction of 2.70 Mtr x 2.70 Mtr x 0.200 Mtr M-25 RCC channel 20 Mtr Long or as per actual requirement at site and Making connection of newly built 2.70 Mtr x 2.70 Mtr x 0.200 Mtr M-25 RCC channel with existing RCC Channel including dewatering of sub soil water of 5mtr below spring level and 6.25 mtr. from ground level or upto bottom of the concrete base whichever is more or any leaked water and , dismantling of concrete with concrete breaker, integration of existing reinforcement with newly laid channel reinforcement, cost of water proofing compound, cost of arrangement for stopping of extra water in channel by putting sand filled bags or MS plate with mortor for Joint sealing or any other kind of arrangement required and all other works contingent there to upto full satisfaction of Engineer-In-Charge. NOTE:- Agency has to lower down the sub soil water upto required depth so that work can be executed without hindrence and no additional cost will be paid for dewatering of sub soil water.....

1

-

-

... More
Supply, installing, testing and commissioning of electrically driven horizontal split casing pump and LT (6.6 kV) induction motor sets as spare CW pumpset arrangement having capacity: 2556Cum/Hr at 15 meter head, identical to pump model(16-20LONOT 60 MK 1), Make Wilo/MatherandPlatt, including pump efficiency 88%, Sp. Gravity 1.0 , Suction Size (mm) 450 (Side) ANSI 16.5 B, Discharge Size (mm) 300 (Side) ANSI 16.5 B, Shutoff Head (Meter) 95, Material of Construction Casing CI IS 210 FG 260 , Impeller SS - 304, Impeller Seal Ring SS - CF8, Casing Wearing Ring Bronze, Pump Shaft EN-8, Shaft Sleeve SS – 410, Type of Sealing Gland Type, Gland Bronze. Motor Rating 160 KW, Speed (RPM) 976 of Marathon/crompton, siemens,ABB, Kirloskar including placing of foundation complete in all respect as per satisfaction of Engineer in Charge. For 2 New Installation at RWPH 1....

2

-

-

... More
Supplying, installing/Commissioning and Testing of Electrical Control Panel complete with semi conductor fuse with ACB EDO (Electrical drought), Amp motor protection relay (Protection from over current, earth fault, short circuit, under voltage over voltage etc.), Capacitor Bank of 500 KVR for each panel, bush bar be electrolytic aluminium of E-91 grade only which will be duly sleeved with heat shrinkable sleeve of suitable rating and color, panel be TTA (Total type test assembler) IS standard-61439 (Part-II) with manufacture or with their official licensed partner made with latest CNC machine and machine pressed for metering and indication to run the pump, panel be free standing, floor and wall mounting, Cubical type, dust and vermin proof, fabricated out of 16 SWG CRC sheet duly powder quoted paint grey shade, compartmentalised and suitable for service voltage of 400/440 V, three phase four wire with starter etc. complete in all respect. Make: Siemens, Schneider, ABB and LandT.....

2

-

-

... More
Providing, stringing out, jointing, cutting of 620 mm outer dia. M.S. pipe of 10mm thick including PU coating outer side of grade E250BR and 25mm 1:3 mortar lining inside complete in all respect as per satisfaction of Engineer-In-Charge as per IS 3589:2001....

3

-

-

... More
Providing, stringing out, jointing, cutting of 165 mm outer dia. M.S. pipe of 5mm thick including PU coating outer side of grade E250BR and 25mm 1:3 mortar lining inside complete in all respect as per satisfaction of Engineer-In-Charge as per IS 3589:2001.....

60

-

-

... More
SITC of group control enabled LED based smart Street light, housing made up of Pressure Die Cast Housing LM 6 Alloy / Anti Dust Exposed Lens, sturdiness and embossed brand name/logo name of manufacturer. The luminaire shall have in-built receiver for central control. The fixture should have high power single LED chip with ceramic base resulting in a minimum system efficacy of 123lumen/Watt and a minimum system lumen output of 14840 lumens and maximum system wattage of 120 Watts. The fixture shall have a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK )=08.The fixture shall have DIMMABLE driver and should have an operating voltage range of 140-270 V, surge protection of )=4KV, PF )0.9 @ full load , THD(10% @ full load and SDCM(5. The luminaire shall have an additional SPD of 10KV. The fixture should be top openable and easy access to the Gear Compartment. The driver should be BIS approved, fully potted and en capsulated with 440V Stress Voltage protection for 8 Hrs. High Cut off : 325V( plus /- 15V) and Auto Restart function should also be available within the fixture. The luminaire, it`s driver and SPD shall be of the same make/manufacturer. The fixture should comply with the parameters as per IS10322. Manufacturer shall have a in-house NABL accredited lab for type testing the luminaires as per IS-10322 and for LM79 test. Make: Signify (Philips)/ Halonix/ HPL/Bajaj/ Regent/Trilux.....

60

-

-

... More
SITC of feeder pillar with 100amp TPN MCCB as incomer along with timer, contactor. Outgoing 4 No`s TPN MCB 63amp/40amp......

3

-

-

... More
Supply of 25mm 4Core Alum. Armoured cable loose in existing pipe or trenches complete with necessary connections ......

5500

-

-

... More
Supply and erection of PVC copper conductor wire 4 core of size 2.50 sq.mm for LED light connection ...

2400

-

-

... More
Providing and installation of ABC Powder MAP90 Fire extinguisher(6 Kg)complete in all respect as per satisfaction of Engineer-In-Charge....

6

-

-

... More
Providing, Fixing and Commissioning of twin Lobe Air Compressor Everest make air blower ET 615 with standard accessories (V-belt, NRV and fully ) orientation flow/ vertical flow, capacity-900 CFM, Installation-Indoor, pulley and Bearing -Oil splash discharge pressure -0.35 kg/cm2 RPM-1701, Opening-150 NB, Inlet condition (pressure/temp)-ATM, Drive-V-Belt Drive, Bearing -Anti friction, main casing, side plates-C.I.GR.FG 260:IS:210 (1993) rotor-SG Irong, seals-Labyrinth Seal, Shafts-EN19 (BS970:1955) Gears-Hardened and Ground Base fame-M.S.Fabriciated Including ABB make motor 30HP, 1450 RPM complete in all respect to the satisfaction of Engineer Incharge . At Filteration Unit-2...

2

-

-

... More
Providing and fixing Mechanical type Bulk Water Meter (Suitable up to 50°c temp.), removable mechanism type, magnetically coupled, having dry dial, hermetically sealed totalizer, retrofittable for pulse output, with flange end connections 100mm i/d...

5

-

-

... More
Providing and fixing Mechanical type Bulk Water Meter (Suitable up to 50°c temp.), removable mechanism type, magnetically coupled, having dry dial, hermetically sealed totalizer, retrofittable for pulse output, with flange end connections 150mm i/d....

5

-

-

... More
Providing and fixing Mechanical type Bulk Water Meter (Suitable up to 50°c temp.), removable mechanism type, magnetically coupled, having dry dial, hermetically sealed totalizer, retrofittable for pulse output, with flange end connections 200mm i/d...

3

-

-

... More
Providing and fixing Mechanical type Bulk Water Meter (Suitable up to 50°c temp.), removable mechanism type, magnetically coupled, having dry dial, hermetically sealed totalizer, retrofittable for pulse output, with flange end connections 250mm i/d....

3

-

-

... More
Providing and fixing Mechanical type Bulk Water Meter (Suitable up to 50°c temp.), removable mechanism type, magnetically coupled, having dry dial, hermetically sealed totalizer, retrofittable for pulse output, with flange end connections 300mm i/d....

3

-

-

... More
Providing and Fixing of 16 Nos SS 304 lotter channel 250 x 3000 x 2mm 8 Nos SS `U` channel 100 x 3000 x 6mm, SS hollow shaft with flanged on top and chool at bottom of size 100mm dio x 5mtr , 1 No. . SS 304 flange 100mm x 20mm , 1 No. SS 304 100mm, chool stand at bottom of size 100mm with all fittings complete in all respect to the satisfaction of Engineer-in-charge ...

3

-

-

... More
Providing , Fixing and commissioning of LandT 3 poledraw out Air Circuit breaker 2000A, SL95315 and breaking capacity 65 KA with all fitting complete in all respect to the satisfaction of Engineer-in-charge. At RWPH 1....

1

-

-

... More
Portable Handheld Ultrasonic Flow meter complete with NABL calibration, rechargeable battery, Transducer sets and accessories for pipe line sizes 15mm to 700mm and complete in all respect to the satisfaction of Engineer-in-charge.....

2

-

-

... More
Providing priming arrangement (vacuum pumps) along with GI pipe fitting conforming to BIS specifications complete in all respects with satisfaction of Engineer in ChargeMake of Pumps: Crompton, Kirloskar, Mather and amp: Platt....

1

-

-

... More
Removing of silt in wet position from sludge settling tanks No. 1,2 and 4 at WTP Basai, Gurugram including bailing out of water and slush with the help of JCB, Labour, Tractor, Tanker and disposed off outside the boundary wall of water works anywhere beyond 3 KM from WTP Basai boundary wall complete in all respect and to the entire satisfaction of Engineer-In-Charge....

1

-

-

... More
Repairing of leakaged socketted joints and specials of CI/DI pipeline including excavation of earth dewatering/bailing out pipeline water, execution of work and all other TandP required complete in all respect as per satisfaction of the engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him (without pig lead, which will be paid extra as per actual consumption) . . . . I.         For 100 mm to 250 mm i/d pipe line

50

-

-

... More
Repairing of leakaged socketted joints and specials of CI/DI pipeline including excavation of earth dewatering/bailing out pipeline water, execution of work and all other TandP required complete in all respect as per satisfaction of the engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him (without pig lead, which will be paid extra as per actual consumption) . . . . II.         For 300 mm to 600 mm i/d pipe line

75

-

-

... More
Repairing of leakaged socketted joints and specials of CI/DI pipeline including excavation of earth dewatering/bailing out pipeline water, execution of work and all other TandP required complete in all respect as per satisfaction of the engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him (without pig lead, which will be paid extra as per actual consumption). . . . III.       For 700 mm i/d pipe line

45

-

-

... More
Repairing of leakaged socketted joints and specials of CI/DI pipeline including excavation of earth dewatering/bailing out pipeline water, execution of work and all other TandP required complete in all respect as per satisfaction of the engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him (without pig lead, which will be paid extra as per actual consumption). . . . IV.      For 800 mm i/d pipe line

45

-

-

... More
Repairing of leakaged socketted joints and specials of CI/DI pipeline including excavation of earth dewatering/bailing out pipeline water, execution of work and all other TandP required complete in all respect as per satisfaction of the engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him (without pig lead, which will be paid extra as per actual consumption). . . . V.     For 900 mm i/d pipe line

45

-

-

... More
Repairing of leakaged socketted joints and specials of CI/DI pipeline including excavation of earth dewatering/bailing out pipeline water, execution of work and all other TandP required complete in all respect as per satisfaction of the engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him (without pig lead, which will be paid extra as per actual consumption). . . . VI.       For 1000 mm to 1200mm i/d pipe line

45

-

-

... More
Providing and Fixing of MS flat ring/clamp of size 75x8 mm around the pipe of water supply line of different size for repair of leakage of pipeline as per the site requirement including rivets, screws, nuts and bolts, washer and rubber sheet for packing etc. complete in all respect and as per satisfaction of Engineer in charge. . . . . MS Flat - 75x8mm Size Rubber sheet – 10mm thick x 250mm width Nuts and bolt of dia 12 mm and 300 mm minimum length I.         For 300 mm to 600mm i/d pipe line

15

-

-

... More
Providing and fixing of complete rotating assembly for wilo MandP make Model 10/12 MME having serial no. 12205179/1. The assembly shall comprises of impeller (LG-2), Neck ring (BB), shaft with sleeve and Nut (SS-410) and logging Ring, Gland and Bearing covers (C I), with suitable bearings in fitted condition, rest of other parts as per MandP standards...

1

-

-

... More
Providing and Fixing of complete Rotating assembly for kirloskar make model MF 40-45. RPM 960 rated flow/pressure 710 m^3/Hr Pump OA No. 087858701..

1

-

-

... More
Repairing of leakaged joints of MS pipe by welding in existing running line including excavation of earth dewatering/bailing out pipe line water, execution of work and all other TandP required complete in all respect as per satisfaction of the Engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him. . . . . II.       For 1200 mm i/d pipe line

12

-

-

... More
Repairing of leakage of burst CI/ DI pipe line with new Pipe (pipe to be Supplied by Dept.) by fixing mechanical joint collar as per IS Standared including excavation of earth dewatering/bailing out pipe line water, execution of work and all other TandP complete in all respect as per satisfaction of the Engineer-In-Charge. The contractor shall repair the leakage within 8 Hr. after telephonic message or SMS conveyed to him. . . . . VII.     For 1000 mm to 1200 mm i/d pipe line

12

-

-

... More
Providing and fixing of storage tank capacity 25 MT for PAC Liquid, made of steel SS-304 (Make Jindal, Tata, Sail, RINL, Electrosteel) including dismantelling of existing structures at Chemical House of each unit, M.S. stand with antirust coating and epoxy paint for fixing the same at site, piping with uPVC pipes for dosing system including SS-elbows, SS-Unions, SS-specials, gate valves etc. complete in all respect. . . . .

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.