Gurugram Metropolitan Development Authority Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Gurugram Metropolitan Development Authority - GMDA Tender

Works
Civil And Construction
Drainage Work
Pipe Line Project
Eprocure
Opening Date23 Jan 2024
Closing Date26 Feb 2024
Tender Amount₹ 18,46,31,566 
Notes
Download

Costs

  • EMD

    ₹ 36,92,640
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Desilting of existing sewer lines with mechanical device i.e. super sucker machine of 270 HP to 400 HP engine driven and installing the plugging in manholes for temporary diversion and taking out rubbish debris, silt etc. All internal debris be removed from the existing sewer line and cleaned with high velocity jet cleaners of 200 PSI pressure according to NASSCO recommended specifications and disposal of the malba/ debris at site as directed by the Engineering -In - Charge. Traffic control arrangements and proper lighting at night, barricading, display of sign boards, Removal of all hindrances/ obstructions unforeseen items all to the satisfaction of Engineer - In - Charge of the work. 700mm - 800mm dia pipe line

800

-

-

... More
Desilting of existing sewer lines with mechanical device i.e. super sucker machine of 270 HP to 400 HP engine driven and installing the plugging in manholes for temporary diversion and taking out rubbish debris, silt etc. All internal debris be removed from the existing sewer line and cleaned with high velocity jet cleaners of 200 PSI pressure according to NASSCO recommended specifications and disposal of the malba/ debris at site as directed by the Engineering -In - Charge. Traffic control arrangements and proper lighting at night, barricading, display of sign boards, Removal of all hindrances/ obstructions unforeseen items all to the satisfaction of Engineer - In - Charge of the work. 900mm - 1000mm dia pipe line

2775

-

-

... More
Providing and installing of Cured -in - Placed - Pipe liner (CIPP Liner) existing sewer pipe line and the design vetted from IIT Delhi / NIIT Kurukshetra / WRC London based on the report of CCTV regarding the deteriorated condition of existing sewer line. The temporary diversion should be provided through the required submersible pumps and Gen set etc. with including the laying rising main from upstream side of working length for smooth flow/bye pass of sewerage system to avoid the flooding in adjoining area. The CIPP liner should be made with Felt (Tube) of make Insituform/Applied Felt/Roders of required size and Resin of make Scottbadder /AOC / Raycold and other specified chemical and material including the machinery and equipments such as Leaflet Hose, Conveyor System, Diesel Operated Water Boiler with injection and suction pumps, Inversion Tower, Hydra, JCB, Support Vehicle, Gen Set of 62 KVA, Air Compressor, Vacuum Machine, Pneumatic Mechanical Mixer with ice buckets, Water Tanker, THF and PU Sheet, Submersible pump, and other safety equipments required at site and skilled / fully trained labour / staff as required for the process of CIPP lining. The CIPP lining should be in proper gradient / slope and including the testing of line after CIPP lining complete in all respect to the entire satisfaction of Engineer -In - Charge. 600mm - 650mm i/d pipe line (minimum thickness 15mm or as per design whichever is on higher side vetted from IIT Delhi /NIIT Kurukshetra / WRC London)

100

-

-

... More
Providing and installing of Cured -in - Placed - Pipe liner (CIPP Liner) existing sewer pipe line and the design vetted from IIT Delhi / NIIT Kurukshetra / WRC London based on the report of CCTV regarding the deteriorated condition of existing sewer line. The temporary diversion should be provided through the required submersible pumps and Gen set etc. with including the laying rising main from upstream side of working length for smooth flow/bye pass of sewerage system to avoid the flooding in adjoining area. The CIPP liner should be made with Felt (Tube) of make Insituform/Applied Felt/Roders of required size and Resin of make Scottbadder /AOC / Raycold and other specified chemical and material including the machinery and equipments such as Leaflet Hose, Conveyor System, Diesel Operated Water Boiler with injection and suction pumps, Inversion Tower, Hydra, JCB, Support Vehicle, Gen Set of 62 KVA, Air Compressor, Vacuum Machine, Pneumatic Mechanical Mixer with ice buckets, Water Tanker, THF and PU Sheet, Submersible pump, and other safety equipments required at site and skilled / fully trained labour / staff as required for the process of CIPP lining. The CIPP lining should be in proper gradient / slope and including the testing of line after CIPP lining complete in all respect to the entire satisfaction of Engineer -In - Charge. 900mm - 1000mm i/d pipe line (minimum thickness 25mm or as per design whichever is on higher side vetted from IIT Delhi /NIIT Kurukshetra / WRC London)

2775

-

-

... More
Providing and installing of Cured -in - Placed - Pipe liner (CIPP Liner) existing sewer pipe line and the design vetted from IIT Delhi / NIIT Kurukshetra / WRC London based on the report of CCTV regarding the deteriorated condition of existing sewer line. The temporary diversion should be provided through the required submersible pumps and Gen set etc. with including the laying rising main from upstream side of working length for smooth flow/bye pass of sewerage system to avoid the flooding in adjoining area. The CIPP liner should be made with Felt (Tube) of make Insituform/Applied Felt/Roders of required size and Resin of make Scottbadder /AOC / Raycold and other specified chemical and material including the machinery and equipments such as Leaflet Hose, Conveyor System, Diesel Operated Water Boiler with injection and suction pumps, Inversion Tower, Hydra, JCB, Support Vehicle, Gen Set of 62 KVA, Air Compressor, Vacuum Machine, Pneumatic Mechanical Mixer with ice buckets, Water Tanker, THF and PU Sheet, Submersible pump, and other safety equipments required at site and skilled / fully trained labour / staff as required for the process of CIPP lining. The CIPP lining should be in proper gradient / slope and including the testing of line after CIPP lining complete in all respect to the entire satisfaction of Engineer -In - Charge. 700mm - 750mm i/d pipe line (minimum thickness 16mm or as per design whichever is on higher side vetted from IIT Delhi /NIIT Kurukshetra / WRC London)

50

-

-

... More
Providing and installing of Cured -in - Placed - Pipe liner (CIPP Liner) existing sewer pipe line and the design vetted from IIT Delhi / NIIT Kurukshetra / WRC London based on the report of CCTV regarding the deteriorated condition of existing sewer line. The temporary diversion should be provided through the required submersible pumps and Gen set etc. with including the laying rising main from upstream side of working length for smooth flow/bye pass of sewerage system to avoid the flooding in adjoining area. The CIPP liner should be made with Felt (Tube) of make Insituform/Applied Felt/Roders of required size and Resin of make Scottbadder /AOC / Raycold and other specified chemical and material including the machinery and equipments such as Leaflet Hose, Conveyor System, Diesel Operated Water Boiler with injection and suction pumps, Inversion Tower, Hydra, JCB, Support Vehicle, Gen Set of 62 KVA, Air Compressor, Vacuum Machine, Pneumatic Mechanical Mixer with ice buckets, Water Tanker, THF and PU Sheet, Submersible pump, and other safety equipments required at site and skilled / fully trained labour / staff as required for the process of CIPP lining. The CIPP lining should be in proper gradient / slope and including the testing of line after CIPP lining complete in all respect to the entire satisfaction of Engineer -In - Charge. 800mm - 850mm i/d pipe line (minimum thickness 18mm or as per design whichever is on higher side vetted from IIT Delhi /NIIT Kurukshetra / WRC London)

750

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.