If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Gurugram Metropolitan Development Authority - GMDA Tender

Works
Electrical and Electronics
Eprocure
Opening Date14 Dec 2023
Closing Date4 Jan 2024
Tender Amount₹ 7,21,54,653 
Notes
Download

Costs

Summary

Providing Smart And Connected Light On Sector Dividing Road Sector 70-75 Gurugram

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Testing and Commissioning of SaaS for 5 years for Individual Light Controls including the API documentation to enable smart city authorities to Integrate with their smart city dashboard.

1

-

-

... More
S/E of underground cable loose in existing pipe or trenches complete with n/connections. 25mmsq x 4 core (unarmored)

23000

-

-

... More
S/E of underground cable loose in existing pipe or trenches complete with n/connections. 50mmsq x 4 core (Armored)

2500

-

-

... More
S/E of underground cable loose in existing pipe or trenches complete with n/connections. 95mmsq x 3½ core (Armored)

400

-

-

... More
Supply and erection of GI pipe 4” (100m) dia, medium class, As per IS: 1239 (I) for wiring purpose with bend complete in all respect upto entire satisfaction of engineer in charge of the work.

125

-

-

... More
Supply and erection of GI pipe for transformer earthing 40mm dia (B-Class) with 12mm dia holes in 100mm dia bore in earth upto moisture level using proper earth electrode upto full length suitable for pole mounting sub station. Earthing should be designed with regards to max. likely earth fault current Depth 0-30 mtr.

3000

-

-

... More
Supply and erection of prestressed cement concrete pole as ISS:1678-1960, 11.00 mtr. long PCC poles 152mmx203mm at top and 152mmx368mm at bottom with working load of 360 Kg, burried 1.8 mtr. in ground complete in all respect.

45

-

-

... More
Supply and erection of 11 KV brown glazed 10 KN pin insulator with GI pin having stalk length 165mm and shank length 150mm with one Nut and Washer small steel head confirming to ISS 731/1971 with latest amendment suitable for normally polluted atmosphere and as per HSEB specification of make approved by DHBVN.

70

-

-

... More
S/E of GO switch vertical mounted type and suitable for 11KV system confirming to ISS 1816/1972 and ISS 2544/1963 with latest version thereof the post insulator should be make JSI/BHEL suitable for 400amp. HT load and fitted on two No. 2.50 mtr. long MS channel of size 100x50x50x6mm 4 Nos MS clamp size 50x6mm with alum. paint and primer upto entire satisfaction including GI pipe, handle and copper blade.

6

-

-

... More
Supply, Installation, testing andcommissioning of 63 KVA outdoor type (ON flushed ) No load ratio/11/0.433 KV ,3 phase,50 Hz, Core type , double alum, wounding , cooling (ONAN) complete with standard fittings as per IS 2026-1977 complete in all respect up to the entire satisfaction of the Engineer in charge of work. (4 star).

3

-

-

... More
S/E of LA set for 11KV distribution system type 5 KVA sets and confirming to IS 3870/1963 with latest amendment complete in all respect as per specification of DHBVN.

3

-

-

... More
Supply and erection of GI pipe for transformer earthing 40mm dia (B-Class) with 12mm dia holes in 100mm dia bore in earth upto moisture level using proper earth electrode upto full length suitable for pole mounting sub station. Earthing should be designed with regards to max. likely earth fault current.Depth 0-30 mtr.

266

-

-

... More
S/E of ISI mark 11 KV XLPE PVC cable armored aluminum conductor cable size 50sqmm x 3 core loose in existing trenches/ pipe complete with necessary connection.

4115

-

-

... More
Horizontal Trenchless boring for laying of HDPE pipe 90/75mm dia to avoid cutting of road and other metaled portion.

375

-

-

... More
Supply and erection of GI pipe 6” dia, (150M) medium class, As per IS: 1239 (I) for wiring purpose with bend complete in all respect upto entire satisfaction of engineer in charge of the work.

198

-

-

... More
Operation and maintenance For 2nd year

12

-

-

... More
Operation and maintenance For 3nd year

12

-

-

... More
Operation and maintenance For 4nd year

12

-

-

... More
Operation and maintenance For 5nd year

12

-

-

... More
Supply and erection of LT fuse unit suitable for 200 KVA transformer including cost of MS clamps, Nut and Bolts etc. complete in all respect upto entire satisfaction of Engineer in charge of work.

3

-

-

... More
Supply, Installation, testing and commissioning of high-quality group control enabled integrated LED Street Light with a minimum system lumen of 16800 lm and system wattage 120W with a minimum system efficacy of 140 lumen/watt . The LED used shall have CCT of 5700K, SDCM must be less than or equal to 5 and CRI must be greater than or equal to 70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure diecast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” and shall not be bolted/welded/mechanically joined to the luminaire housing to ensure robust design. The luminaire shall have polycarbonate front cover/lens. The name of the brand should be embossed/engraved and should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 75K hours@L70. Product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 and impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 10 KV/5KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 5KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The LED used in the luminaire shall be SMD type only and shall be from either, APT Electronics and CREE make or equivalent. The Driver should be asphalt potted and should be a BIS approved driver. The driver shall be replaceable. The driver shall have operating voltage of 120V to 270V, PF=0.95 @full load, THD=10% @ full load, In-built surge protection of 4KV. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown/cut-off at less than 90V and 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 and IEC 61000-3-2. The driver shall be EMI/EMC Complied as per EN55015/CISPR15. The luminaire shall be able to give Constant Light output (CLO) between voltage range of 140V to 277V. The luminaire driver and it’s SPD shall be of the same make/manufacturer/Lighting company as that of LED luminaires. Luminaire manufacturer must have Inhouse NABL accredited lab to conduct LM79, Type test as per IS10322, `FAT` before dispatch as per IS 10322 and IK Test. The detailed specifications shall be as per tender.

700

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.