Gurugram Metropolitan Development Authority Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Gurugram Metropolitan Development Authority - GMDA Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date12 Jun 2024
Closing Date2 Jul 2024
Tender Amount₹ 59,55,62,676 
Notes
Download

Costs

  • EMD

    ₹ 1,19,11,254
  • Document Cost

    ₹ 1,180
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying 50mm - 75 mm dense graded bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder VG 40 @ 4.5% by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete, as per technical clause No. 505 of MORTandH specifications.

3507.36

-

-

... More
Providing and applying tack coat with penetration grade bitumen VG - 10 using bitumen pressure distributor at the rate of 0.30 kg per sqm on the prepared bituminous/ granular surface cleaned with mechanical broom as per technical clause 503 of MORTandH specifications...

212102.09

-

-

... More
Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.85 kg/sqm using mechanical means as per technical clause 503 of MORTandH specifications...

223404.64

-

-

... More
Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.of MORTandH specifications..

23349.13

-

-

... More
Providing and Laying Reinforced cement concrete pipe NP4/prestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1 :2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets 1600 mm dia.

378

-

-

... More
Providing and Supplying, and installation of Plate Earthing material with copper strips 25 X 5 mm including plate at bottom with salt, coal, ammonium chloride, with 8 inch to 1.5 inch PVC pipe and pit cover on top. Complete job 15 ft to 20 ft deep with satisfaction of Engineer-in charge.

28

-

-

... More
Supply, Installation, Testing and Commissioning of LED Street Light with a minimum system lumen of 35000 lm and system wattage not exceeding 250W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM = 5 and CRI=70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” and shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved and should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 75K hours@L70. Product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 and impact resistance shall be IK10. The minimum luminaire dimensions shall be L: 630mm, W: 255MM, H: 135MM (with control gear compartment) and nominal weight shall be 3.8KG (±10%) and minimum windforce area of 0.121sq.m. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 10 KV/5KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 5KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The LED used in the luminaire shall be SMD type only and shall be from either Signify, Philips, Osram, Nichia, APT Electronics and CREE make or equivalent. The Driver should be asphalt potted and should be a BIS approved driver. The driver should be 1-10V dimmable future proof driver. The driver shall have operating voltage of 120V to 270V, PF=0.95 @full load, THD=10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547, IEC 61000-3-2 and CISPR15. The luminaire shall have SPD bolted in-side the luminaire. The luminaire driver and it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, `FAT` before dispatch as per IS 10322 and IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of luminaire. The LED Luminaire and it`s driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, IK test report issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire and Driver.

325

-

-

... More
Supply, Installation, Testing and Commissioning of LED Street Light with a minimum system lumen of 5400 lm and system wattage not exceeding 45W with a nominal system efficacy of 120 lumen/watt. The LED used shall have CCT of 5700K, SDCM = 5 and CRI=70. The housing should be made of non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The luminaire LED shall have declared Lifetime of 50K hours@L70. Product should be designed for continuous operation (10-12 Hrs. per day), The Ingress protection should be minimum IP66 and impact resistance shall be IK07. The minimum luminaire dimensions shall be L: 274mm, W: 84MM, H: 76MM (with control gear compartment). The luminaire shall have nominal weight of 0.85KG (±10%) and minimum wind force area of 0.023sq.m.. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 10 KV/5KA SPD duly bolted in the Luminaire. The luminaire should be of Class B Serviceability. The LED used in the luminaire shall be SMD type only and shall be from either Signify, Philips, Osram, Nichia, APT Electronics and CREE make or equivalent. The Driver should be asphalt potted and should be a BIS approved driver. The driver shall have operating voltage of 140V to 270V, PF=0.95 @full load, THD=10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs, 320V for 48 Hrs. The driver should Auto Shutdown at = 320V (±15V) and Auto Recovery at 300 - 315V and Should Auto Shutdown at = 90V and Auto Recovery at = 100V ±5V. The driver should be potted. The driver shall comply to IEC61547 and IEC 61000-3-2. The luminaire shall have SPD in-side the luminaire. The luminaire driver and it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, `FAT` before dispatch as per IS 10322 and IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of luminaire. The LED Luminaire and it`s driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, IK test report issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire and Driver.

284

-

-

... More
Supply, Installation, Testing and Commissioning of LED Street Light with a minimum system lumen of 12600 lm and system wattage not exceeding 90W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM = 5 and CRI=70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” and shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved and should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 75K hours@L70. Product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 and impact resistance shall be IK10. The minimum luminaire dimensions shall be L: 435mm, W: 200MM, H: 135MM (with control gear compartment) and nominal weight shall be 1.8KG (±10%) and minimum windforce area of 0.062sq.m. . Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 10 KV/5KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 5KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The LED used in the luminaire shall be SMD type only and shall be from either Signify, Philips, Osram, Nichia, APT Electronics and CREE make or equivalent. The Driver should be asphalt potted and should be a BIS approved driver. The driver should be 1-10V dimmable future proof driver. The driver shall have operating voltage of 120V to 270V, PF=0.95 @full load, THD=10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547, IEC 61000-3-2 and CISPR15. The luminaire shall have SPD bolted in-side the luminaire. The luminaire driver and it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, `FAT` before dispatch as per IS 10322 and IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of luminaire. The LED Luminaire and it`s driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, IK test report issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire and Driver.

697

-

-

... More
Supply, Installation, testing and commissioning of high-quality LED Flood Light with a minimum system lumen of 36000 lm and system wattage not exceeding 300W with a nominal system efficacy of 120 lumen/watt. The LED used shall have CCT of 5700K, SDCM = 5 and CRI=70. The housing should be made of non-corrosive h-pressure die-cast aluminum, to withstand extreme environments. The luminaire shall have declared Lifetime of 50K hours@L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 and impact resistance shall be IK07. The front cover shall be toughned glass. The minimum luminaire dimensions shall be L: 380mm, W: 192MM, H: 77MM (with fins). The luminaire shall have nominal weight of 4KG (±10%). The Luminaire should have a 10 KV/5 KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 5KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The LED used in the luminaire shall be SMD type only and shall be from either Lumileds, Osram, Nichia, APT Electronics/ CREE make or equivalent. The luminaire shall have multiple beam angles option to meet different road widths for the same stretch to ensure same look of the housing. The driver shall have operating voltage of 120V to 270V, PF=0.95, THD=10% @ full load. The driver should Auto Shutdown at = 320V and Auto Recovery at 300 - 315V and Should Auto Shutdown at = 90V and Auto Recovery at = 100V ±5V. The luminaire driver and it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, `FAT` before dispatch as per IS 10322 and IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of luminaire. The LED Luminaire and it`s driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, IK test report issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire and Driver.

60

-

-

... More
Providing and fixing of thimble 16mm aluminium including making connections punching thimbles, complete with the satisfaction of Engineer in charge.

10791

-

-

... More
Constructing brick masonry manhole in cement mortar 1: 4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1 :1.5:3 mix (1 cement : 1.5 coarse sand (zone-Ill) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-Ill) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 2.5 m deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg). with common burnt clay non modular bricks of class designation 7.5 Complete in all respect as per satisfaction of Engineer-in-charge

23.44

-

-

... More
Constructing brick masonry manhole in cement mortar 1: 4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1 :1.5:3 mix (1 cement : 1.5 coarse sand (zone-Ill) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-Ill) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 1.450 m deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) With common burnt clay non-modular bricks of class designation 7 .5 Complete in all respect as per satisfaction of Engineer-in-charge

606.75

-

-

... More
Providing and laying of ASTM UPVC PIPE SCH-40 2` to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.

200

-

-

... More
Providing and laying of Service Saddle 63/50mm x 40 mm Size Make- to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work

1100

-

-

... More
Providing and laying of Air Release Valve 1` Dia Size, to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work

110

-

-

... More
Providing and laying of Screen Semi Automatic Filter 2.5 ` 30m3/hr to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.

10

-

-

... More
Providing and laying of 2` Dia. Solenoid globe Valves with fabric reinforced diaphragm and rugged PVC durable glass -filled nylon construction, compatible with and slow closing to prevent water hammer, pressure rating upto 10.4 KSC to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.

17

-

-

... More
Providing and laying of Automation Controller 4 Station, to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.

8

-

-

... More
Providing and laying of Powder Coated ENCLOSER BOX FOR AUTOMATION CONTROLLER to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.

8

-

-

... More
Providing and laying of Voltage Stabilizer to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.

8

-

-

... More
Providing and laying of Powder Coated Filter Support Unit to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.

16

-

-

... More
Providing and laying of Pressure Relief Valve size 2` dia to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.

10

-

-

... More
Providing and laying of sprinklers to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. for horticulture

1100

-

-

... More
Providing and laying of MTAandFTA to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.

2000

-

-

... More
Providing and laying 2.5 sq mm single core wire to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.

1000

-

-

... More
Providing and laying of ASTM UPVC Pipe Fittings like T, Band, Socket and valve to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.

100

-

-

... More
Providing and laying of 40 Mm PVC Ball Valve to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.

1000

-

-

... More
Credit of unusable material received from milling of BC i.e 80% of obtained material(deduction). The quantities of the above material have been worked out on the basis of theoritical quantities laid on this road. However agency may visit before quoting rates and asses the extent of retrieved material. There shall be no measurement after actual scarifying/milling and if material after milling is found on lesser side, no claim of agency on this scoe will be entertained and full recover on the basis of quoted rate and quantity exhibited in the BOQ shall be made. the reverse rates are minimum rates to be used as base for quoting purchase rate by the agency. No rates below reserve price will be considered for all purpose in case the agency quotes lesser than reserve price. The price quoted against the recovery material shall have minimum reserve price of 2194.00/- per cum).

10333.41

-

-

... More
Credit of Steel reinforcement of 80% length for R.C.C work recovered from existing drain available at site, where not included in the complete rate rate of RCC dismantle, Complete as per Engineer in charge. The quantities of the above material have been worked out on the basis of theoritical quantities laid on this road. However agency ma visit before quoting rates and asses the extent of retrieved material. There shall be no measurement after actual scarifying/dismantling and if material after dismantling is found on lesser side, no claim of agency on this score will be entertained and full recovery on the basis of quoted rate and quantity exhibited in the BOQ shall be made. The reverse rates are minimum rates to be absured as base for quoting purchase rate by the agency. No rates below reverse price will be considered for all purpose in case the agency quotes lesser than reserve price. The price quoted against the recovery material shall have minimum reserve price of 30.50/- per kg.

97272

-

-

... More
Credit of kerbstone (70% of total length) (the amount computed by the rates quoted against recovery itmes will not be included in the total amount rather it will be deducted while calculating financial statement of the agency, kerbstones obtained from dismantling of existing median, islands has been calculated taking assumption that 70% of existing kerbstone will be retreived and can be reused. The reserve rates are minimum rates to be used as base for quoting purchase rate by he agency. No rates below reserve price will be considered for all purpose, in case the agency quotes lesser than reserve price, the price quited against the recovery of existing kerbstones shall have minimum reserve price of Rs. 1988/- per cum).

835.3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.