Guru Jambheshwar University Of Science And Technology Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Guru Jambheshwar University Of Science And Technology - GJUS Tender

Works
Electrical and Electronics
Eprocure
Opening Date29 Mar 2025
Closing Date16 Apr 2025
Tender Amount₹ 66,31,800 
Notes
Download

Costs

  • EMD

    ₹ 1,32,636
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
[HSR 24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. [Through Rate]

40

-

-

... More
[HSR 24.15.7]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in 1 per meter below ground level with sand and bricks with all labour and material including digging and refilling of trench as required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 7. 185 Sq mm 3 core [Through Rate]

1700

-

-

... More
[HSR 24.16.7]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 7. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 185 Sq mm 3 core [Through Rate]

100

-

-

... More
[HSR 24.2.10]LT CABLE 10. Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S. Rod welded/riveted at the top with 10 cm dia 3 mm thick MS plate inscribed with cable word on it, having a cross arm 30 cm long of the same dia welded at the bottom, in exiting trench 45 cm below ground level. [Through Rate]

40

-

-

... More
[HSR 24.3.3.2]HT CABLE 3.2. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :150 to 185 sqmm [Through Rate]

4

-

-

... More
[NS Item] Dismantling/removing of old 11KV 400 AMP Oil Circuit Breakers, including taking out the same from Sub station complete in all respects as per instructions of engineer in charge.

7

-

-

... More
[NS Item] Supply installation, testing and commissioning 11KV, 475MVA, 25KA/3 sce, 630A, OUTGOING VCB Panel (Indoor Type) Make-(ABB / Siemens/Schneider/C G) Complete in all respect as per instructions of Engineer in Charge and nothing extra shall be paid. BASIC UNIT MOTORIZED (220 V) AC with anti pumping device 630 Amp Aluminium Bus bar with PVC Sleeves 1 No. Shunt Trip Coil and Close Coil 24V DC inbuilt Rear Cable Box-1 No. suitable for 1x3Cx50 sqmm XLPE cable. CT, 3 Nos. 1-Phase, 11 KV, 25KA/3 Sec. Indoor Single Phase resin Cast Ratio-150-75/5-5A Core -2:15 VA ,SP-10 Protection Core -1:15 VA ,CLASS: 0.5,Metering METERS (Siemens make) DIGITAL AMMETER WITH SELECTOR SWITCH DIGITAL VOLTMETER WITH SELECTOR SWITCH DIGITAL TRIVECTOR WITH MDI, class-1 LED Installing Lamps, Breaker on RED Breaker off Green, Spring Charged Blue Trip Circuit Healthy White with Push Button Auto Trip Indication Amber R-Y-B Phase Indication Accessories TNC Switch, Heater with Thermostat and Switch Illumination Lamp with Switch, 3 Pin Plug Socket with Switch Protection Relays (Siemens / LandT Make) 3-Pole, IDMT Relay (2 Nos Overcurrent plus 01 Nos Earth Fault) Master Trip relay, Auxiliary relay

7

-

-

... More
[NS Item] Supply installation, testing and commissioning 11KV, 475MVA, 25KA/3 sce, 800A, Incoming/Outgoing( 800 Amp) VCB Indoor/ Outdoor Type. Make-(ABB / Siemens/Schneider/C G) Complete in all respect as per instructions of Engineer in Charge and nothing extra shall be paid. BASIC UNIT MOTORIZED (220 V) AC with anti pumping device 800 Amp Aluminium Bus bar with PVC Sleeves 1 No. Shunt Trip Coil and Close Coil 24V DC inbuilt Rear Cable Box-1 No. suitable for 1x3Cx240 sqmm XLPE cable. CT, 3 Nos. 1-Phase, 11 KV, 25KA/3 Sec. Indoor Single Phase resin Cast, Ratio-400-200/5-5A Core -2:15 VA ,SP-10 Protection Core -1:15 VA ,CLASS: 0.5,Metering Potential transformer Fixed Type Indoor Single Phase resin Cast RATIO: 11KV/v3/110V/v3 100 VA,Class:0.5, 12 KV,3.15A P.T.Fuse unit METERS DIGITAL AMMETER WITH SELECTOR SWITCH DIGITAL VOLTMETER WITH SELECTOR SWITCH DIGITAL TRIVECTOR WITH MDI, class-1 LED Installing Lamps, Breaker on RED, Breaker off Green Spring Charged Blue Trip Circuit Healthy White with Push Button Auto Trip Indication Amber, R-Y-B Phase Indication Accessories TNC Switch, Heater with Thermostat and Switch Illumination Lamp with Switch 3 Pin Plug Socket with Switch Protection Relays (Siemens / LandT Make) 3-Pole, IDMT Relay (2 Nos Overcurrent plus 01 Nos Earth Fault), Master Trip relay, Auxiliary relay

2

-

-

... More
Deduct - [NS Item] Credit/recovery rate for old 11KV 400 Amp OCB (Oil Circuit Breaker) of Crompton make (about 23/24 years old) being in operational/functional condition, as to be received after dismantling on as and where basis, (dismantling/removing of OCBs installed at substations shall be paid under separate item taken in the DNIT). The agency shall take away the material i.e. OCBs at the price quoted by the agency but the minimum price to be quoted should not be less than the reserve price/recovery rate as fixed and mentioned under:- 11KV 400 Amp OCB @ Rs. 20000/- each Note:- The reserve price/recovery rate is the minimum rate to be used as a base for quoting the purchase rate by the agency. No rate below the reserve price will be entertained and the reserve price will be accounted for all purposes if the agency quotes less than the reserve price. It is made clear that in case any agency quotes the recovery rate of OCB less than the reserve price mentioned above, the recovery rate of OCB given as reserve price i.e. Rs. 20000/- each shall be considered in the financial statement for working out L-1 or L-2 and so on by making necessary correction/modification if required: and recovery on the same rate shall be made from the agency. It shall be binding upon all agencies participating in the tender. However, the agency may visit at site before quoting a recovery rate..

7

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.