If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 28,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_HRY_103242_1Bid Award Id
ViewTender No
PROVIDING DUCTABLE TYPE AIR CONDITIONERS OT - PRETender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://haryanapwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Pdg. and fixing degital metering equipment for L.T.Cubical panel consiting of 96 x 96 mm, 0-500 volts, voltmeter with selector switch, Amp meter ( of required ratio upto 600/5 ampere) with selector switch and required CT's 3 Nos., a set of 3 phase indicating lamps RYB LED
1
-
-
Supply & fixing of rotary handle for on / off operation of existing MCCB in the LT panel including fixing the same in position with all labour and material required to complete the job in all respect Rotary handle up to 125 A, MCCB
4
-
-
Rotary handle above 125 A, MCCB
1
-
-
Supply and erection of moulded case circuit brecaker single pole/ 4 pole on wall/ on existing pedestal including bounding to earth and making necessary connection required to complete the job the job in all respect up to the entire satisfaction of the Engineer -in - Charge of the work. Make L&T/ABB/Havells/ Standard/ C&S 4 pole MCCB 200 amp.
1
-
-
Supply and erection of heavy duty 4 pole ON load changeover load brecaker switch comprising of switches 63 amp. To 100 amp. Suitable for operation on 415 V 50 Hz AC supply complete with handle assembly having door interlook & padlocking arrangement on existing panel/ including making necessary connections with petty material required to complete the job. Make L&T/ABB/ Havells/ Standard/ C&Sv200 amp. 4 pole ON load changeover switch
1
-
-
Ductable Air-Conditioning Units SITC of Air-conditioning system (Air- Cooled type) Ductable units with Scroll Compressor working on R-22/R-32/R-410 Refrigerarnt suitable for 415 Volt 50Hz 3 Phase power supply. The heat exchanger for Outdoor shall be constructed with copper tubes mechanically bonded to aluminium fins to form a cross fin coil. The Condenser fins must be coated with Anti-corrosive treatment.The following safety devices shall be part of the outdoor unit:- High Pressure Switch, Low Pressure Switch, Fan Motor Safety Thermostat, Over Current Relay, Fusible Plugs, Fuses etc. 4.0 TR Ductable units Make:- Daikin/ Mitsubishi (Electric) / O-General
4
-
-
Supply, fabrication and installation of MS Base frame with Viberation isolation pads suitable for supporting the outdoor unit of 4.0 Tr. Nominal capacity. The MS Frame should be Cleaned and apply one coat of preimer and two coats of black epoxy paint including civil work etc. with labour and material copmlete in all rspect upto the entire satisfaction of engineer-in-charge of work.
4
-
-
PIPING AND VALVES Refrigerant Piping Supply, installation and testing of phosphoric acid De-Oxidised seamless Copper Refrigerant Piping tested as per JIS HS 3300 standards, clean inner surface and capped before delivery, of good quality with test certificates insulated with 13 mm Nitrile rubber. Guage of Copper as per standards Brazing Rods shall be hard solder, Phospher copper solder of (Harris) make including with labour and material complete in all respect upto the entire satisfaction of engineer-in-charge of work. Make : Mandev/ Met tube/ Maxflow5/8 OD ( Insulation = 13 mm)
80
-
-
1/2 OD ( Insulation = 13 mm)
80
-
-
Condensate Drain Piping Providing & fixing of Rigid PVC Drain piping with 10kg/sqcm pressure rating complete with fittings, supports and duly insulated with 6 mm thick closed cell Elastomeric Foam Insulation with basis Nitrile rubber. The piping shall be supported on C.I channel supports placed at every 2 mtrs with labour and material complete in all rspect upto the entire satisfaction of engineer-in-charge of work. Make : Polycab/ Polypack or equivelent32 MM DIA (Insulation = 6 mm)
100
-
-
DUCT WORKSSupply, installation, testing and commissioning of fabricated GI Rectangular sheet metal ducting with supports, dampers etc. as per ISI specification of below guages complete in all respect upto the entire satisfaction of engineer-in-charge of work. Make : Tata / Jindal/Sail 24 Gauge
80
-
-
22 Gauge
80
-
-
Supply, installation, testing and commissioning of closed cell Nitrile rubber insulation of following thickness applied with Proper adhesive and sealed with 75 mm wide BOPP Tape on all longitudinal/ transverse joints etc. complete in all respect upto the entire satisfaction of engineer-in-charge of work. Make Superlone/ K-flex or equivelent 9 mm thick on ducts in conditioned space
180
-
-
Supply, installation, testing and commissioning of 32 kg / m3 insulation in the form of 25 mm Thick Fiber Glass boards, 2 Layers of Tissue paper finished with 28 gauge perforated Aluminum sheet with nuts, bolts etc. as per standard specifications complete in all respect upto the entire satisfaction of engineer-in-charge of work.25 mm thickness acoustic lining
25
-
-
Supply, Installation, testing and Commissioning of fire retardent flexible Canvas Connection supply air from indoor unit to Supply duct Complete in all respect upto the entire satisfaction of engineer-in-charge of work.
4
-
-
Supply/Return Air Grills: Supplying, installing, testing and balancing of Supply/ Return air grills of various sizes complete in all respect upto the entire satisfaction of engineer-in-charge of work. Make : Dynamic/Ravistar/ Carykire Supply, installation, testing & commissioning of extruded aluminum supply/Return air grilles.
1.5
-
-
Supply, installation, testing & commissioning of volume control MS dampers.
1.5
-
-
Supply, installation, testing & commissioning of Powder Coated aluminum supply/Return air Diffusers.
2
-
-
POWER & CONTROL WORKS Supply, laying, testing and commissioning of power cabling as per specification including end termination as required Complete in all respect upto the entire satisfaction of engineer-in-charge of work. For Outdoor Indoor Unit Connectivity Supply, installation and testing of communication of Copper cabling for connection between the indoor & outdoor unit of 4.0 TR Nominal capacity as per manufacturere guidelines that should pass through existing PVC Condiut pipe complete in all respect upto the entire satisfaction of engineer-in-charge of work. Make Havells/Polycab/ RR Kabelv4 X 4.0 Sq. mm Copper Conductor Cable
100
-
-
For Isolator to Outdoor Unit Supply, installation and testing of Copper cabling connection between the Outdoor unit to Isolator of 4.0 TR Nominal capacity as per manufacturere guidelines that should pass through existing PVC Condiut pipe Complete in all respect upto the entire satisfaction of engineer-in-charge of work. Make Havells/Polycab/ RR Kabel 4 X 6.0 Sq. mm Copper Conductor Cable
100
-
-
Misc Works All necessary civil works like cutting & chasing of walls/floor/ glass and dismantle old ducts and false ceiling etc. and make them good thereof. Scafolding required for hanging of ducts, equipment Complete in all respect upto the entire satisfaction of engineer-in-charge of work.
1
-
-
PVC Batten Providing and fixing of PVC batten Heavy duty size 75 X 75mm for Running Copper Refrigerant Piping/Electrical Cabling Complete in all respect upto the entire satisfaction of engineer-in-charge of work.