Public Works Department Tender
... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 19,120Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_HRY_91430_2Bid Award Id
ViewTender No
PWD/P2/5409-5608Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://haryanapwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Cement concrete 1:1 1/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centring and shuttering , laid in position, complete in all respect. (HSR 10.82 + 10.95 a)
10.28
-
-
... More
First class brick work laid in cement sand mortar 1:6 in foundation and plinth. (HSR 11.2)
73.44
-
-
... More
Providing & fixing PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. (b) 150mm dia PVC pipe 6 kg. pressure (Note:- Reputed make PVC Pipe such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. (HSR 13.89 (b)
Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
594.08
-
-
... More
Kotah Stone flooring, minimum 25mm thick, in any pattern as specified over 20mm thick base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing. (HSR 14.62)
Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
2.88
-
-
... More
12mm thick cement plaster 1:4. (HSR 15.5)
217.32
-
-
... More
Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12)
0.12
-
-
... More
Fe-500 EQR TMT steel bars for RCC works where not including in the complete rate of RCC including bending, binding and placing in position complete. (18.22)Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. From the length so measured, the weight of reinforcement shall be calculated in tones on the basis of IS:1732.Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
20.56
-
-
... More
P.H. items
Providing and placing in horizontal layers filtering media Screened, washed and cleaned as described below:- (a) Top Layer. Fine sand screened, cleaned and washed and graded (effective size 0.2 to 0.4 mm with uniformity coefficient 2.0 to 3.0) from Ghaggar or other approved source. (HSR 28.50 (a)
24.96
-
-
... More
(c) Third layer.
Bajri screended washed and graded from 6 mm to 20 mm (from Ghaggar or approved equivalent quarry).
24.96
-
-
... More
(e) Bottom Layer.
Broken stone, screened, washed and graded from 50 mm to 75 mm (from Ghaggar or approved equivalent quarry).
49.96
-
-
... More
Constructing brick masonry inspection chamber sizes as given below upto 0.60 meters average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement RCC 1:2:4 slab 100mm thick/C.C. topping 50mm thick with 455mm x 455mm / 455mm x 610mm inside light duty C.I inspection chamber cover and frame weight as per I.S.I specification painted with 3 coats of black bitumastic superior paint complete as per standard design. (a) Size 450mm x 450mm inside (with 455mm x 455mm cover and frame light duty single seal weighing 40 kg with C.C. topping). (HSR 29.84 (a)
12
-
-
... More
Size 450mm x 600mm inside (with 455mm x 610mm cover and frame light duty single seal pattern I weighing 38 kg with C.C.topping).
24
-
-
... More
EXTRA FOR EVERY 0.30 METRE DEPTH OF INSPECTION CHAMBER. (a) 450 mm x 450 mm. (HSR 29.85 (a)
12
-
-
... More
Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:2 cement sand mortar over manhole inlcuding carriage loading, unloading, stacking handing re-handling etc. complete in all respect to the satisfaction of Engineer-in-charge. (c) Type Heavy Duty Set (MD-10)-560mm clear opening. (HSR 29.94 (c)
8
-
-
... More
N.S. items
Providing & fixing PVC pipe (6kg/ cm2) dule slotted IS-4985:1988 including cost of adhesive, carriage, loading, unloading etc. (make Supreme, Diplast or any reputed make) complete in all respect as per approval of the Engineer-in-Charge of the work. (i) 160mm i/d. (NS)
65
-
-
... More
Providing & fixing Steel bar embedded plastic steps of size 263mm x 165mm of orange colour, conforming to specifications, in pump chambers, manholes etc. having mnimum 3mm thick polypropylene polymer confirming to IS: 10910 encapsulated on 12mm dia ribbed steel bars per IS : 1786. (NS)
48
-
-
... More
Boring in clay for jointing & lowering PVC/ UPVC sloted pipe 160mm bore upto 30 mtr. (appx.) depth including filling gravel packing around the pipe complete in all respect as per approval of the Engineer-in-Charge of the work. Note: depth of bore will be decided by the Engineer-in-Charge as per ground water table of the area at site. (NS)
66.2
-
-