Faridabad Smart City Limited Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Faridabad Smart City Limited Tender

Works
Civil And Construction
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 Dec 2024
Closing Soon17 Jan 2025
Tender AmountRefer Documents 
Notes
Download

Costs

  • EMD

    ₹ 35,67,000
  • Document Cost

    ₹ 1,180
  • Tender Fee

    ₹ 1,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
GI strip 25*6 mtr 9 mtr for earthing wt 10.80kg (TATA/SAIL make)

108

-

-

... More
Resistivity testing charges for checking of water strata

2

-

-

... More
`Labour charge for making tee connection with existing line excavation, cutting, jointing and making and making connection with existing line complete in all respects`

2

-

-

... More
Add Cost of connection charges for 1Nos, Electric Connection to be deposit with DHBVN including file charges, security, testing charges, energy meter etc. load 10HP)

2

-

-

... More
Providing and fixing Kerb Inlet in storm water drain 450mm wide X 150mm height

40

-

-

... More
Providing and laying Saucer Drain 300x300x100 mm

1000

-

-

... More
Erection of GI strip 25 X 6 mm, 9 Meter For earthing

108

-

-

... More
Supply, installation, testing and commissioning of outdoor type Street Light Control Panel conform with IS: 2147. Floor / wall/ structure mounted, free standing, suitable for cable entry from bottom side, dust proof, vermin proof, 3 phase and neutral, bus bar aluminium, neutral bus shall be of same size as phase bus bars, Short circuit capacity for the bus bars and MCB shall be 10 kA with incomer of 63A FP MCB and outgoing of 6 Nos.16A FP MCB

1

-

-

... More
Providing and Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED and should be SMD type . The System level Luminaire efficacy )=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted and has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @)=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor )0.95 driver Efficiency )85% ,THD(I) 70 and CCT 5700K plus 355K. Surge protection shall be min = 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , LED Street Light fixture 120 Watt

30

-

-

... More
Providing and Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED and should be SMD type . The System level Luminaire efficacy )=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted and has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @)=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor )0.95 driver Efficiency )85% ,THD(I) 70 and CCT 5700K plus 355K. Surge protection shall be min = 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR. LED Street Light fixture 90 Watt

30

-

-

... More
Providing and Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted and has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy )=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @)=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor )0.95 ,driver Efficiency )85% , THD(I) =4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index )70 and CCT 5700K ±355K. Driver current. High Power LED Flood Light 240W

30

-

-

... More
Providing and Fixing of ISO certified company made IK10 IP65 protected Top/Bottom mounted LED Post top Light system. Fixture made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy = 90 Lumen/W. SMD LEDs is to be used, System CRI)70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted and has a unique BIS R number must be potted and has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency ) 85%, PF)0.9, THD output in Cool white or Warm White Colour as per engineers choice. driver current (1000mA shown in LM79 report. Fixture must be in compliance with BIS Standards and T.C . Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR. 30 W LED Post Top Fixture

50

-

-

... More
Supplying and Installation of maintenance free earthing (Chemical Earthing)

108

-

-

... More
Trenchless HDD method for laying of HDPE pipe including laying of cable, digging and refilling

200

-

-

... More
Supply and fixing double pole 240 volt Isolator in the existing MCB DB complete with connections including testing and commisioning etc. as required.40 amps

6

-

-

... More
Supply and fixing double pole 240 volt Isolator in the existing MCB DB complete with connections including testing and commisioning etc. as required.63 amps

6

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity )99.6 % and as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 and 14001 certifications for quality assuarance and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR. 3.5 core 300 sq.mm

250

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity )99.6 % and as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 and 14001 certifications for quality assuarance and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR. 3.5 core 240 sq.mm

250

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity )99.6 % and as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 and 14001 certifications for quality assuarance and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR. 3.5 core 185 sq.mm

500

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity )99.6 % and as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 and 14001 certifications for quality assuarance and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR 3.5 core 120sq.mm

500

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity )99.6 % and as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 and 14001 certifications for quality assuarance and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR. 3.5 core 95sq.mm

250

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity )99.6 % and as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 and 14001 certifications for quality assuarance and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR. 3.5 core 70sq.mm

250

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity )99.6 % and as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 and 14001 certifications for quality assuarance and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR. 3.5 core 50sq.mm

500

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity )99.6 % and as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 and 14001 certifications for quality assuarance and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR. 3.5 core 35sq.mm

1000

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity )99.6 % and as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 and 14001 certifications for quality assuarance and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR. 3 core 35sq.mm

500

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured copper cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Copper conductor of electrlytic grade copper, purity )99.97 % ISI marked as per IS:1554 P-I / IS :7098 P - I (b) conductor shall made of copper rods confirming to IS 613-1964, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 and 14001 certifications and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR . 4 core 16sq.mm

750

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured copper cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Copper conductor of electrlytic grade copper, purity )99.97 % ISI marked as per IS:1554 P-I / IS :7098 P - I (b) conductor shall made of copper rods confirming to IS 613-1964, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 and 14001 certifications and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR . 4 core 10sq.mm

750

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured copper cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Copper conductor of electrlytic grade copper, purity )99.97 % ISI marked as per IS:1554 P-I / IS :7098 P - I (b) conductor shall made of copper rods confirming to IS 613-1964, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 and 14001 certifications and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR . 4 core 6sq.mm

1000

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured copper cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Copper conductor of electrlytic grade copper, purity )99.97 % ISI marked as per IS:1554 P-I / IS :7098 P - I (b) conductor shall made of copper rods confirming to IS 613-1964, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 and 14001 certifications and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR . 4 core 4sq.mm

1000

-

-

... More
Providing and Laying P.V.C. / XLPE insulated and P.V.C. sheathed Un armoured / Armoured copper cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Copper conductor of electrlytic grade copper, purity )99.97 % ISI marked as per IS:1554 P-I / IS :7098 P - I (b) conductor shall made of copper rods confirming to IS 613-1964, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 and 14001 certifications and its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure `A` attached with this BSR . 3 core 4sq.mm

1000

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 300 sq. mm (70mm)

20

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 240 sq. mm (62mm)

36

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 185 sq. mm (57mm)

20

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 120 sq. mm (45mm)

25

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 95 sq. mm (45mm)

25

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 70 sq. mm (38mm)

35

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 50 sq. mm (35mm)

30

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 35 sq. mm (32mm)

30

-

-

... More
Providing and erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width and 100 mm height comprising all required standard accessories.

60

-

-

... More
Providing and Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy = 120 lm/Watt output, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% ,p.f.=0.95, CRI )80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure `A` attacheded with this BSR. 4` LED Tube shape fixture 18/20 W (Extruded Al Base)

276

-

-

... More
Providing and Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy = 120 lm/Watt output, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% ,p.f.=0.95, CRI )80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure `A` attacheded with this BSR. 2` LED Tube shape fixture 9/10 W (Polycarbonate Base)

12

-

-

... More
Providing and Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing and Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short and Open circuit protection, having efficiency ) 85% and in compliance to IEC standards. System Lumen efficacy of = 120 lm / watt, THD ( 10 % ,p.f.=0.95, CRI )80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure `A` attacheded with this BSR. Recessed Mounting LED Downlight 14/15W

130

-

-

... More
`Providing and Fixing of energy efficient direct fit (Retrofit) Polycarbonate /Extruded Al Base Housing and diffuser SMD Mid Power LED tube (with integral driver), on existing fixture. Power Consumption of 18W / 20W system lumen efficacy = 110 lm/Watt output, internal surge protection of 2.5 KV ,THD ( 15% ,p.f.=0.95,CRI )80 , life time of minimum 35000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure ``A`` attached with this BSR. ` 4`, 18/ 20 Watt LED Tube Without Batten (Extruded Al Base)

24

-

-

... More
`Providing and Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted and has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy )=120 lm/ wt. with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cut-off @)=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor )0.95 ,driver Efficiency )85% , THD(I) =4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, colour Rendering Index )70 and CCT 5700K ±355K. Driver current High Power LED Flood Light 150W

30

-

-

... More
Supply, Installation, Testing and commissioning of outdoor type free standing feeder Pillar having configuration of 100A AL colour sleeved busbar, Voltmeter with VSS, IEC 60947/IEC 60898 compliant breakers, IP 54 with canopy. Incomer of (1) Thermal Magnetic based 100A, 35kA TPN MCCB, Ics=100% of Icu and Outgoing of (1) 10A,10kA TPN C curve MCB:9 nos., (2) 16A,10kA TPN C curve MCB: 4 nos.,(3) Thermal Magnetic based 40A, 35kA TPN MCCB, Ics=100% of Icu: 5 nos.

2

-

-

... More
Ground Floor Panel HVAC Panel -_ INCOMER -_ TPN MCCB with CT`s, indication Lamps etc. -_ BUSBARS SECTIONS-100 amps TPN, 25kA, 430volts grade busbar chamber of suitable length with Al busbars. All busbars and interconnections shall be of suitable size Al busbar, current density of bus-bars shall not be more than 0.8 Amps/ sq.mm cross sectional area of Bus Bar. -_ -OUTGOING SECTION -_ all the ratings and quality of incomer and outgoing are as per SLD

1

-

-

... More
First HVAC Panel -_ INCOMER -_ 1 Nos. TPN MCCB with CT`s,indication Lamps etc. -_ BUSBARS SECTIONS-100 amps TPN, 25kA, 430volts grade busbar chamber of suitable length with Al busbars. All busbars and interconnections shall be of suitable size Al busbar, current density of bus-bars shall not be more than 0.8 Amps/ sq.mm cross sectional area of Bus Bar. -_ -For OUTGOING SECTION Refer SLD

1

-

-

... More
Common Services Panel -_ INCOMER -_ 1 Nos. TPN MCCB with Interlocking with CT`s,indication Lamps etc -_ BUSBARS SECTIONS -_ 100 amps TPN, 10kA, 430volts grade busbar chamber of suitable length with Al busbars. All busbars and interconnections shall be of suitable size Al busbar, current density of bus-bars shall not be more than 0.8 Amps/ sq.mm cross sectional area of Bus Bar. -_ OUTGOING SECTION -_ Refer SLD

1

-

-

... More
Supplying and erecting 350 kVAr, 440 V three phase, 50 Hz., thyrister switched micro APFC passive filter panel, consisting of suitable steps of APP type capacitor units with harmonic filter reactors, as per specification no CP-ED/APFC

1

-

-

... More
`Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints and expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 1600 A 50kA SC for 1 sec

16

-

-

... More
`Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector MCCB, connections, earthing etc. as required. 400 A TPN`

2

-

-

... More
Supplying, installing, testing and commissioning of following capacity TPN distribution tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with HRC fuses, interconnections, earthing etc. as required. 32 A TPN, 8 way

2

-

-

... More
Supplying, installing, testing and commissioning of following capacity TPN distribution tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with HRC fuses, interconnections, earthing etc. as required. 63 A TPN, 8 way

2

-

-

... More
Supplying, installing, testing and commissioning of following capacity TPN distribution tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with HRC fuses, interconnections, earthing etc. as required. 16 A TPN, 6 way

2

-

-

... More
Supplying Installing, testing and commissioning of 63mm mm dia single headed Gun metal Hydrant Valve with flanged inlet, stop valve, spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 5.5 Kgf/cm2 of pressure with blank cap and wheel as per IS 5290 etc. complete as per specifications. Make : WINCO/NEW Age including cost of materials, labour, HOM

10

-

-

... More
Supplying and fixing Single headed external yardhydrant valve with 1 No. 63 mm dia instantaneous FMGunmetal/Stainless Steel coupling and cast iron wheel,ISI marked, conforming to IS 5290 (type A) with blankGunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel

5

-

-

... More
Supplying Installing, testing and commissioning of 20mm dia 40m length hose with rubber lining smooth bore, reinforced of natural/synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric marked with minimum thickness of 1.50mm and to with stand a working pressure of 1OKgf/sqcm confirms and tested as per IS 444 including cost of materials, labour, HOM complete as per specifications.

20

-

-

... More
Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x15mm dia as per IS 903 Make: WINCO/NEW AGE complete including cost of materials, labour, HOM complete as per specifications.

22

-

-

... More
15.00 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.65 mm dia

1

-

-

... More
15.00 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.200mm dia

2

-

-

... More
Supplying Installing, testing and commissioning of Reinforced Rubber Lined RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 WINCO/NEW AGE complete including cost of materials, labour, HOM complete as per specifications.

30

-

-

... More
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG

8

-

-

... More
Pressure Switch(PS) 13-7-15 Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS

8

-

-

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 5.5 kg/cm2 complete as required

3

-

-

... More
Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve (size 400 x 400 x 400mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8`x6`) and locking arrangement with necessaryfixing material such as rubber bidding etc. duly painted in post box red colour.

6

-

-

... More
Supplying and erecting M.S./CRCA cabinet for housing FireBrigade / SIEMESE connections (size 1250 x 400 x 300 mm.)made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8` x 6`) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.

2

-

-

... More
Supplying Installing, testing and commissioning of hydraulicallying operated sprinkler cabit Valve with water meter gong bell and trims as required, pressure gauges drain Valve, ball Valves check valve, strainer etc. including cost of materials, labour, HOM complete as per specifications.do- 150 mm dia

2

-

-

... More
Providing, fixing, testing and commissioning ofinstallation control valve of cast iron body,brass/bronze working parts comprising of water motoralarm, bronze seat clapper, clapper arm andhydraulically driven mechanical gong bell to soundcontinuous alarm when the wet riser/sprinkler systemactivates, pressure gauges, emergencyreleases, strainer, pressure switch, cock valve complete withdrain valve and bypass, test control box, ball valves,MS pipe of required size, flanges, orifice plate, gasket, etc of follwing sizes as required : 150mm dia

2

-

-

... More
Supplying, installation, testing and commissioning ofsprinkler flexible pipe (UL Listed) of stainless steelcomplete with 15 NPT on reducer thread withmaximum workingpressure of 175 PSI test pressure of875 PSI (Burst) with branch line (Inlet) 25mm NPTmale thread to sprinkler head (Outlet) 15mm NPTfemale thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete asrequired.1500mm

250

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required : (It should be factory ready made) 2 way-100 mm dia Pipe

2

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required : (It should be factory ready made) 4 way - 150 mm dia Pipe

1

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

2

-

-

... More
25mm Air release valve as per IS:14845 ISI Marked

5

-

-

... More
Supplying, installation, testing and commissioning ofelectric driven terrace pump suitable for automaticoperation and consisting of following, complete in allrespects, as required: (Terrace Pump)(a) Horizontal type, multistage, centrifugal, split casingpump of cast iron body and bronze impeller with stainlesssteel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC typesuitable for operation on 415 volts, 3 phase, 50 Hz, ACsupply with IP55 class of protection forenclosure, horiziontal foot mounted type with Class-`F` insulation,conforming to IS-325.(c) M.S.fabricated common base plate, coupling, couplingguard, foundation bolts etc.as required. (d) Suitablecement concrete foundation duly plasteredand with anti vibration pads. -_ 900 lpm at 35 m Head

1

-

-

... More
Electric driven pressurisation pump suitable forautomatic operation and consisting of following,complete in all respects, as required : (Jockey Pump)Horizontal type, multistage, centrifugal pump of castiron body and bronze impeller with stainless steel shaft,mechanical seal conforming to IS : 1520.Suitable HP squirell cage induction motor TEFC typesuitable for operation on 415 volts, 3 phase 50 HzAC supply with IP 55 class of protection for enclosure,horizontal foot mounted type with Class-`F` insulation, conforming to IS : 325.M.S.fabricated Common base plate, coupling, couplingguard, foundation bolts etc. as required.Suitable cement concrete foundation duly plasteredand with anti vibration pads. -_ 180 lpm at 70 m Head

1

-

-

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump (Sprinkler and Hydrant) suitable for automaticoperation and consisting of following, complete in allrespects, as required :(a) Horizontal type, multistage, centrifugal, split casingpump of cast iron body and bronze impeller with stainlesssteel shaft, mechanical seal conforming to IS 1520.(b) Suitable HP Squirrel cage induction motor, TEFC,synchronous speed 1500 RPM, suitable for operationon 415 volts, 3 phase 50 Hz, AC supply with IP 55protection for enclosure, horizontal foot mounted typewith Class-`F` insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, couplingguard, foundation bolts etc. as required.(d) Suitable cement concrete foundation duly plasteredwith anti vibration pads. -_ 2280 lpm at 70 m Head

1

-

-

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump (Sprinkler and Hydrant) suitable forautomatic operation and consisting of following,complete in all respects, as required : (Diesel DrivenPump)Horizontal type, multistage, centrifugal pump of cast ofiron body and bronze impeller with stainless steel shaft,mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator,diesel engine conforming to relevant IS standardcomplete with auto starting mechanism, 12 /24 voltselectric starting equipment, diesel tank, exhaust pipeextended upto 10 m outside pump house duly insulatedwith 50 mm thick glass wool with 1.0 mm thickaluminium sheet cladding, residential silencer,instruments and protection as per standardspecification, stop solenoid for auto stop in the event offault with audio indications, painted with post office redcolour etc. as required.M.S fabricated, common base plate, coupling, couplingguard, foundation bolts etc. as required.Suitable cement concrete foundation duly plasteredand with anti vibration pads. -_ 2280 lpm at 70 m Head

1

-

-

... More
Supply installation, testing and commissioning of fire alarm Main panel with zone indication alaram etc. as required including cost of materials, labour, HOM complete as per specifications.

2

-

-

... More
Supplying and erecting ABC Dry Chemical Powder type Fire extinguisher 4 kg capacity cartridge tyB with gun metal cap 150 gram CO2 gas cartridge powder and brackets conforming to IS 2171-1985 and complete erected with necessary clamps made from 50x6mm MS flat with nuts and bolts grouted in wall complete

10

-

-

... More
Providing 4.5Kg C0 Wheel Type2 Providing 4.5Kg C02 gas valve type Fire Extinugisher, Tro lley Mounted, Easy Weight Management used Unused Mechanism, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MMDiameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8andC Fire, 8 Rating 138, Can Constuction : Hot spinning/Forging, Valve Construction : Forgingand Machining, Internal Coating of Can : Not Applicable, External coatingof Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved,1 YearWarranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, HOM complete as per specifications.

10

-

-

... More
Providing and fixing flow switch in following sizes M.S.pipe including connection etc as required.50mm dia

2

-

-

... More
Providing and fixing flow switch in following sizes M.S.pipe including connection etc as required.

1

-

-

... More
Providing and fixing flow switch in following sizes M.S.pipe including connection etc as required.100 mm dia

5

-

-

... More
Providing and fixing flow switch in following sizes M.S.pipe including connection etc as required.150mm dia

3

-

-

... More
Supply, Installation testing and commissioning of approved make heavy tubes (Class `C`) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick@ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,1OOmm Nominal bore5.40mm thick@ 14.40 Kg/m,150mm Nominal bore 5.40mm thick@ 21. 20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.-do- Galvanized Iron Pipes 150 mm dia

150

-

-

... More
Supply, Installation testing and commissioning of approved make heavy tubes (Class `C`) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick@ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,1OOmm Nominal bore5.40mm thick@ 14.40 Kg/m,150mm Nominal bore 5.40mm thick@ 21. 20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications-do- Galvanized Iron Pipes 100 mm dia

90

-

-

... More
Supply, Installation testing and commissioning of approved make heavy tubes (Class `C`) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick@ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,1OOmm Nominal bore5.40mm thick@ 14.40 Kg/m,150mm Nominal bore 5.40mm thick@ 21. 20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications -_ do- Galvanized Iron Pipes 80 mm dia

30

-

-

... More
Supply, Installation testing and commissioning of approved make heavy tubes (Class `C`) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick@ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,1OOmm Nominal bore5.40mm thick@ 14.40 Kg/m,150mm Nominal bore 5.40mm thick@ 21. 20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications -_ -do- Galvanized Iron Pipes 65 mm dia

15

-

-

... More
Supply, Installation testing and commissioning of approved make heavy tubes (Class `C`) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick@ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,1OOmm Nominal bore5.40mm thick@ 14.40 Kg/m,150mm Nominal bore 5.40mm thick@ 21. 20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications -_ do- Galvanized Iron Pipes 50 mm dia

60

-

-

... More
Supply, Installation testing and commissioning of approved make heavy tubes (Class `C`) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick@ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,1OOmm Nominal bore5.40mm thick@ 14.40 Kg/m,150mm Nominal bore 5.40mm thick@ 21. 20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.-do- Galvanized Iron Pipes 40 mm dia

57

-

-

... More
Supply, Installation testing and commissioning of approved make heavy tubes (Class `C`) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick@ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,1OOmm Nominal bore5.40mm thick@ 14.40 Kg/m,150mm Nominal bore 5.40mm thick@ 21. 20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.-do- Galvanized Iron Pipes 32 mm dia

50

-

-

... More
Supply, Installation testing and commissioning of approved make heavy tubes (Class `C`) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick@ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,1OOmm Nominal bore5.40mm thick@ 14.40 Kg/m,150mm Nominal bore 5.40mm thick@ 21. 20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.-do- Galvanized Iron Pipes 25 mm dia

310

-

-

... More
Supply, Installation testing and commissioning of approved make heavy tubes (Class `C`) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick@ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,1OOmm Nominal bore5.40mm thick@ 14.40 Kg/m,150mm Nominal bore5.40mm thick@ 21. 20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.-do- Galvanized Iron Pipes 150 mm dia

100

-

-

... More
Supply, Installation testing and commissioning of approved make heavy tubes (Class `C`) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick@ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,1OOmm Nominal bore5.40mm thick@ 14.40 Kg/m,150mm Nominal bore5.40mm thick@ 21. 20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.-do- Galvanized Iron Pipes 100 mm dia

150

-

-

... More
Supplying Installing, testing and commissioning of 15mm dia quartized bulb type sprinkler of rating 68 degree centigrade with required accessories Standard Spray (Upright Type)

300

-

-

... More
Supplying Installing, testing and commissioning of 15mm dia quartized bulb type sprinkler of rating 68 degree centigrade with required accessories Standard Spray (Pendant Type)

370

-

-

... More
Supplying Installing, testing and commissioning of 15mm dia quartized bulb type sprinkler of rating 68 degree centigrade with required accessories Horizontal Side Wall Sprinkler

40

-

-

... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system ( which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol Bacnet/ Modbus over IP complete as per specifications. Ten Loop Panel

1

-

-

... More
Supplying, installation, testing and commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required

33

-

-

... More
Supplying, installation, testing and commissioning of Intelligent Addressable type multisensor detector (Photo plus Fixed Tempt. plus Rate of Rise Tempt.) with base for use as heat or smoke or combined both automatic electronic addressing, microprocessor type with built in integrated short circuit isolator with operating tempurature from -20°C to plus 60°C. Detector shall have auto learn, drift compensation etc. As per tender specification.

60

-

-

... More
Supply, installation, testing and commissioning of Intelligent Addressable Control module with IP66 casing containing four relay outputs, each containing a potential-free DPDT contact with a fail-safe and in-built short circuit isolator The ambient temperature range shall be -20C to plus 60C.

3

-

-

... More
Supply, installation, testing and commissioning of Intelligent Addressable break glass type Manual Call Point having inbuilt short circuit isolator and LED indicator with back box.

7

-

-

... More
Supplying and laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring and FRLS outer sheath complete as required.

1500

-

-

... More
Intelligent Addressable loop powered Sounder having integrated short circuit isolator. It shall not required separate interface module/ power cable.

3

-

-

... More
Supplying and fixing of UPVC WC connector (straight or bend type) with rubber lip ring. Including 110 mm dia UPVC pipe of required length and proper connection complete as required.

48

-

-

... More
Supplying and Fixing in position 100 mm dia UPVC Multi traps of self cleaning design including 125 mm dia brass C.P. grating, jointing, embedding in concrete etc. complete. Rate to include making of opening in floor, marble / tiles, for fixing C.P gratings ( suitable for pipes).

10

-

-

... More
Supplying and fixing of fully automatic ss `No Touch` Hand drier suitable to operate on 230 volts, single phase 50 Hz, A.C. power supply and directly plugged to power point complete.

4

-

-

... More
Providing and fixing wall mounted water closet of size 780x370x690 mm including all accessories, complete in all respect.

8

-

-

... More
Providing and Installation of Galvanised Steel angle hanger (Ceiling angle) (Size 25x1 Ox0.50 mm). Complete in all respect.

4

-

-

... More
Providing and Fixing Towel rings in stainless steel having 1 mtr size. (Stainless Still Rose Gold Acute Towel Ring, For Bathroom)

4

-

-

... More
Providing and fixing Hindware Elegance Basin Tap Brass Chrome Finish Silver, F340001. (Including all fitting and accessories)

15

-

-

... More
Providing and Mixing Hindware Amazon Stop Cock Brass Chrome Finish Silver, F320007. (Including all fitting and accessories)

15

-

-

... More
Providing and Fixing 12mm transparent, toughened glass in door/windows/partitions/others as per office requirements. The work includes all tools, tackles, labours, materials required for completion of work in all respect. (Make- Saint gobain, Borosil)

400.37

-

-

... More
Providing and fixing bright finished 100mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door with necessary screws etc. complete as per direction of Engineer in charge.

54

-

-

... More
Providing, lowering, laying, aligning, fixing in position CI Duckfoot bend in pipe line as per IS:1538 (amended up to date) suitable for potable water at all level/ depth including all material, labour hydraulic testing and commissioning as per technical specifications and as per direction of Engineer for following sizes: 100 mm dia each

6

-

-

... More
Hub less centrifugally cast (spun) iron terminal guard (slotted cowl) -100 mm dia as per IS 15905

2

-

-

... More
Providing and fixing G. I. Barrel Nipple (reducer) in G.I. Pipe line i/c cutting threading testing etc. complete New work) confirming to IS: 1879 50x100mm

2

-

-

... More
Providing and fixing G. I. Union in G.I. Pipe line i/c cutting threading testing etc. complete (New work) confirming to IS 1879 50mm dia

2

-

-

... More
Providing and fixing G. I. Union in G.I. Pipe line i/c cutting threading testing etc. complete (New work) confirming to IS 1879 100mm dia

2

-

-

... More
Providing and fixing G. I. Elbow in G.I. Pipe line i/c cutting threading testing etc. complete (Old work) confirming to IS: 1879 50mm dia

2

-

-

... More
Providing and fixing G. I. Elbow in G.I. Pipe line i/c cutting threading testing etc. complete (Old work) confirming to IS: 1879 100mm dia

4

-

-

... More
Providing and fixing G. I. threaded Flange in G.I. Pipe line i/c cutting threading testing etc. complete (New work) confirming to IS: 1879. 100mm dia

4

-

-

... More
Providing, Laying, Jointing and field testing of HDPE pipes (High Density Polyethylene Pipes) confirming to IS 4984/14151/12786/13488 with necessary jointing material like mechanical connector of jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic and leak proof joint by thermosetting process. It may be required to be done with Jack/ Hydraulic Jacks/ Butt fusion machine. (50 mm and above fusion jointed andbelow 50mm mechanical jointed).110 mm dia- (Presure-10 Kg/ sq.cm)

200

-

-

... More
Supply Installation, Testing and Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V plus /- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 . 20 HP VRV X Outdoor Unit ( 3 Nos. For Gound Floor plus 2 Nos. For First Floor )

115

-

-

... More
`Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 3.2 TR (4 No. At Ground Floor plus 4 No. at First Floor )

8

-

-

... More
`Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.` 2.0 TR

28

-

-

... More
`Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.` 1.65 TR

4

-

-

... More
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : ` 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation`

351

-

-

... More
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

351

-

-

... More
BOOM BARRIER-Entry/Exit mechanical operated gate

2

-

-

... More
Effluent Treatment Plant UG Tank with reuse of treated water (50,000 Ltr capacity) including GST

1

-

-

... More
Providing and laying of 75 mm thick Moorum on prepared bed including supplying and consolidation etc complete in all respect a per direction of Er.(Cost evaluated as per HSR-21 rates)

111.3

-

-

... More
Supplying, installation, testing and commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.(Note : Power Amplifire shall be 500W for the complete configuration)

4

-

-

... More
Supplying, installation, testing and commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.

4

-

-

... More
Supplying, installation, testing and commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.

10

-

-

... More
Supplying, installation, testing and commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required.

10

-

-

... More
Supplying and laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring and LSZH outer sheath complete as required.

2000

-

-

... More
Supply, installation, testing and commissioning of MDF patch panel prepackaged with wiring block with legs, insert labels, label holders, jumper troughs, metal back panel duct assembly, screws washers and an instruction sheet for termination of incoming pairs. Rate shall include suitable size of lockable 1.6mm thick CRCA sheet steel enclosure duly powder coated. The cost shall be complete with fixing arrangements, foundations etc as required 100 pair Tag Block

2

-

-

... More
Supply, installation, testing and commissioning of MDF patch panel prepackaged with wiring block with legs, insert labels, label holders, jumper troughs, metal back panel duct assembly, screws washers and an instruction sheet for termination of incoming pairs. Rate shall include suitable size of lockable 1.6mm thick CRCA sheet steel enclosure duly powder coated. The cost shall be complete with fixing arrangements, foundations etc as required Patch Cord for Voice 1 mtr for rack end

111

-

-

... More
Supply, installation, testing and commissioning of Riser cable consisting of multiple core or solid copper conductors of 24 AWG size insulated with expanded polyethylene covered by a PVC skin and inner shielding for grounding. The core shall be covered by a layer of plastic tape and overlaid with a corrugated PVC plastic. The cable shall be as per the specifications laid down in the tender 100 Pair

30

-

-

... More
Supply, installation, testing and commissioning of 4 pair Category 6 cable consisting of 23 AWG solid copper conductors and as per the specification. The cable should have flexible jacket and ripcord for easy stripability. 4-Pair

111

-

-

... More
Providing and fixing in position the following 16 gauge PVC conduits concealed or exposed as called for including all accessories i.e. bends, junction boxes, outlet boxes with cover plates of approved make and design. 25 mm dia conduit

125

-

-

... More
Supply and installation, testing and commissioning following size KRONE make telephone tag block in lockable 16 gauge sheet steel enclosure complete as required completely flushed mounted. 50 pair Krone type tag block

2

-

-

... More
Supply and installation, testing and commissioning following size KRONE make telephone tag block in lockable 16 gauge sheet steel enclosure complete as required completely flushed mounted. Junction tag Box

2

-

-

... More
Supply and installation of flush mounted Category 6 T 568 A or B outlet with G.I back box of adequate depth for good termination and all required accessories. The plastic shall be high impact, flame-retardant UL rated thermoplastic. Dust cover / Blank shall be provided to protect unused face plate openings. Termination cap and plastic cover shall be provided to protect jack wiring. Single outlet face plate with RJ-11 jack

111

-

-

... More
Door Locks

36

-

-

... More
Erection of street light, bracket, wall mounting or hanging type

50

-

-

... More
Supplying and erecting ready to use Retrofit T8 LED 18 / 20 tube light with poly-carbonate body, heat sink, integrated HF electronic driver complete and compatible to T8 / T12 LED luminary by disconnecting starter and ballast if necessary.

5

-

-

... More
Lightening Arrestor Complete Set (9 KV, 5 KA)

2

-

-

... More
Providing and fixing Hand shower (health faucet) with 8mm dia. 1m long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.

4

-

-

... More
Supplying and fixing of UPVC WC connector (straight or bend type) with rubber lip ring. Including 110 mm dia UPVC pipe of required length and proper connection complete as required.

48

-

-

... More
Supplying and Fixing in position 100 mm dia UPVC Multi traps of self cleaning design including 125 mm dia brass C.P. grating, jointing, embedding in concrete etc. complete. Rate to include making of opening in floor, marble / tiles, for fixing C.P gratings ( suitable for pipes).

10

-

-

... More
Supplying and fixing of fully automatic ss `No Touch` Hand drier suitable to operate on 230 volts, single phase 50 Hz, A.C. power supply and directly plugged to power point complete.

4

-

-

... More
Revolving Chair for Office use

50

-

-

... More
Office Table

50

-

-

... More
Wooden Almirah for office use

10

-

-

... More
Computer System with UPS and All accessories

10

-

-

... More
Bio metric attendence reader wit finger prints and face recognisation with application. (Including all).

20

-

-

... More
Supply installtion Testing commissioning of 8.0 Megapixel , BULLET Camera with 4 megapixel HD 2.8-12mm Varifocal Lens, 36 IR LED upto 20 meters, Supports Android Apps.including outdoor housing with fixing arrangement etc ( IP66) Protection. POE Based as Required.

12

-

-

... More
Supply installtion Testing commissioning of 4.0 Megapixel , IP Vandal Dome Camera with 2 megapixel HD 2.8-12mm Varifocal Lens, 36 IR LED upto 10 meters, Supports Android Apps IP54 Protection Rating. POE Based as Required.

12

-

-

... More
Supply installtion Testing commissioning of Include NVR Software having Recording Storage System complete for whole system and camaras consisting sufficient nos. of 8 channels video recording on D1 resolution at real time, Support 4 hot-swappable hard disk direct attached. Recording Storage for 30 days at 25 fps H.264 resolution including 16 TB HDD Per NVR, Video survelience series HDD as required. with PC server, capable of managing and controlling recording parameters with high end features as required . License covers 10 video channels,.

1

-

-

... More
Supply installtion Testing commissioning of 40` Wall Mounted LCD for display as required as per specifications and drawing

2

-

-

... More
Supply installtion Testing commissioning of 9U Rack with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and accessories as mentioned in the BOQ above and including all connections and terminations as required.

1

-

-

... More
Supply installtion Testing commissioning of PoE Ethernet switch with suitable rack with 46 ports RJ45 10 base 1000 T with complete as required -Network Switch

2

-

-

... More
Supply, Laying, termination, Installtion of 2 Core, 1.5 sqmm solid cu. conductor cable as required as per specifications

2000

-

-

... More
Supply, Laying, termination, Installtion of UTP CAT6 (A) armoured Cable as required as per specifications and Drawing.

3000

-

-

... More
Supply, Laying, termination, Installtion of 25mm PVC Conduit 1.8 mm thick as required as per specifications

1000

-

-

... More
ANPR camera with LPU (including all accessories)

6

-

-

... More
PTZ-Camera -4 MF with power supply complete along wth mountry accessories

4

-

-

... More
Integration and interface of all camera software, DBR, controllers, ports etc including ICCC. Complete in all respect

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.