Faridabad Metropolitan Development Authority Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 1,14,060Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_HRY_339764_1Tender No
202342D18FD0 F35B 4640 990D 3870CD8B92C81851002Tender Authority
Faridabad Metropolitan Development Authority ViewPurchaser Address
-Website
http://etenders.hry.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Copper conductor flexible cable for pumps of size 2.5 sqmm 3 core. Make - Finolex/LAPP/Polycab/RR/
KEI/Havells.
405
-
-
Copper conductor flexible cable for lights of size 1.5 sqmm 4 core Make - Finolex/LAPP/Polycab/RR/
KEI/Havells.
4105
-
-
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the
Engineer-in-charge of the work.
240 sqmm (HSR-2023-Cable Laying and Street Lighting item no-24.2.8.13)
2
-
-
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the
Engineer-in-charge of the work.
300 sqmm (HSR-2023-Cable Laying and Street Lighting item no-24.2.8.14)
2
-
-
L.T. PANELS : Design, manufacture, testing at works, supply ,installation, testing and commissioning of
415V Main LT Panel Type Tested Assembly – TTA, CPRI /Independent international test house tested for all
the tests as per IEC61439-1 and 2 and internal arc tests as per IEC 61641 V2, 50kA for 0.4 sec at HBB,VBB
and cable chamber. Copies of the test certificates shall be submitted with the tender. LT Panel shall also be
tested of design as per Seismic Zone 4 of IEC 60068-3-3 requires compliance against 0.4g acceleration. Panel
shall be rated for Impulse withstand capability equal to or greater than the switchgears inside the panel. For
operator safety IP2 X (touch proof) protection to be available even after opening the feeder compartment door.
The compartmentalization to be achieved by using metal separators, use of PVC sheet / Hylem sheets shall not
be allowed. Main LT Panel shall be form 4b, for form of separation and rest with form 3b ,only metallic covers
shall be used, Hylem / PVC sheets shall not be allowed. The panel shall be FRONT operated, suitable for bus
duct entry for transformer incomings. Outgoing panels shall be suitable for cable entry from the top/bottom.
The type tested design of the Switchboard shall be proven design from the main switchgear manufacturer
(OEM).However, panel shall be manufcatured by OEM / Lisenced partner of OEM. Type test reports shall be
provided by the manufcaturer. The MLTP shall be complete in all respect including necessary painting as per
the approved shade, fully complying as per Technical Specification and SLD and approved makes and in all
respect with all accessories and fittings etc. for trouble free
operation. [LT MAIN PANEL IN THE SUBSTATION outdoor panel)
1
-
-
SITC of VCB as per StandardSupply of 11KV 21KA 2 way RMU, manual with 1 Isolator, 1 VCB Outdoor
Type, Non
1
-
-
Supply and laying of 120 mm dia (OD-120 mm and ID-103 MM Nominal) HDPE pipe (duly ISI Marked)
under ground in trenches in horizontal direction across the road, as per direction of Engineer-In-Charge
including jointing of pipe, cleaning etc., providing suitable covers on mouth of pipes, excavation of pits of
required size at a depth of 0.3 meters to .5 meters etc. complete as
200
-
-
SITC of 5HP borewell Submersible pump set with necessary fitting Mounts
1
-
-
SITC Of 3` brass gate Valve with proper fittings
4
-
-
SITC of 2`X2`X1` gate valve pit with cover as per Standard
4
-
-
SITC of 1 HP mud submersible pump with 100ft hose pipe
2
-
-
1C x 10 sqmm earthing Cable
500
-
-
Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing
masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal
or coke and salt) etc. complete as required.(HSR-2023-Cable Laying and Street Lightingitem no-24.1.4)
4
-
-
Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with
all labour and material.(HSR-2023-Cable Laying and Street Lightingitem no-24.1.10)
18
-
-
PDB for power distribution in different panel
1
-
-
100 mm dia PVC (HSR-2023-Basic Rate of Materials-B0241)
174
-
-
PVC Bend 100 dia (HSR-2023-Basic Rate of Materials-B0239)
12
-
-
2`PVC Pipe
124
-
-
2`PVC Elbow
16
-
-
2` PVC Tee
40
-
-
Supply and Laying of 90 mm 10kg PVC Pipe boring to fountain pole complete with 10 kg PVC Fitting ,Elbow
,Tee ,MTA Accsessories as per site condition work includes trenching fixing of pipe and covering as per the
the direction of Engineer -incharge
1
-
-
Electrical Installations , Fire Fighting Detection and Alarm System COPPER WIRING IN MS CONDUIT
(SURFACE/RECESS)
Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick
MS conduit pipe. Group A(HSR-2023-. Electrical Installations , Fire Fighting Detection and Alarm System-
23.1)
4
-
-
Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core
for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required.
1 run of Size 4 Sqmm(1/2.24mm). (HSR-2023-. Electrical Installations , Fire Fighting Detection and Alarm
System-23.6.3)
10
-
-
Supply Installation testing and commissionin of 1.5 tonne 5 star rated split AC complete in all respect and as
directed by engineer in charge
2
-
-
Water Supply NA CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as
per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge
56` (1400mm) (HSR-2023-Water supply item no-20.71/2)
1
-
-
Supply installation testing and commssioning of the ceiling fan with the following specifications:
i. Sweep: 1400mm
ii. Minimum RPM: 300
iii. Power consumption: 75w
Complete in all respects and as directed by engineer in charge
1
-
-
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS
etc. recessed in wall including
bonding to earth with all labour and material required to complete the job in all respect up to the entire
satisfaction of the Engineer-in-Charge of
the work. SPN DB Double Door 12 way ( 2 incoming and 10 outgoing) (HSR-2023-. Electrical Installations ,
Fire Fighting Detection and Alarm System-23.22/4.3)
1
-
-
SP MCB 6-32 A (HSR-2023-Basic Rate of Materials-EL115)
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements