Faridabad Metropolitan Development Authority Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Faridabad Metropolitan Development Authority - FMDA Tender

Works
Electrical and Electronics
Eprocure
Opening Date27 Dec 2023
Closing DateCancelled
Tender Amount₹ 57,02,699 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Copper conductor flexible cable for pumps of size 2.5 sqmm 3 core. Make - Finolex/LAPP/Polycab/RR/ KEI/Havells.

405

-

-

... More
Copper conductor flexible cable for lights of size 1.5 sqmm 4 core Make - Finolex/LAPP/Polycab/RR/ KEI/Havells.

4105

-

-

... More
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 240 sqmm (HSR-2023-Cable Laying and Street Lighting item no-24.2.8.13)

2

-

-

... More
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 300 sqmm (HSR-2023-Cable Laying and Street Lighting item no-24.2.8.14)

2

-

-

... More
L.T. PANELS : Design, manufacture, testing at works, supply ,installation, testing and commissioning of 415V Main LT Panel Type Tested Assembly – TTA, CPRI /Independent international test house tested for all the tests as per IEC61439-1 and 2 and internal arc tests as per IEC 61641 V2, 50kA for 0.4 sec at HBB,VBB and cable chamber. Copies of the test certificates shall be submitted with the tender. LT Panel shall also be tested of design as per Seismic Zone 4 of IEC 60068-3-3 requires compliance against 0.4g acceleration. Panel shall be rated for Impulse withstand capability equal to or greater than the switchgears inside the panel. For operator safety IP2 X (touch proof) protection to be available even after opening the feeder compartment door. The compartmentalization to be achieved by using metal separators, use of PVC sheet / Hylem sheets shall not be allowed. Main LT Panel shall be form 4b, for form of separation and rest with form 3b ,only metallic covers shall be used, Hylem / PVC sheets shall not be allowed. The panel shall be FRONT operated, suitable for bus duct entry for transformer incomings. Outgoing panels shall be suitable for cable entry from the top/bottom. The type tested design of the Switchboard shall be proven design from the main switchgear manufacturer (OEM).However, panel shall be manufcatured by OEM / Lisenced partner of OEM. Type test reports shall be provided by the manufcaturer. The MLTP shall be complete in all respect including necessary painting as per the approved shade, fully complying as per Technical Specification and SLD and approved makes and in all respect with all accessories and fittings etc. for trouble free operation. [LT MAIN PANEL IN THE SUBSTATION outdoor panel)

1

-

-

... More
SITC of VCB as per StandardSupply of 11KV 21KA 2 way RMU, manual with 1 Isolator, 1 VCB Outdoor Type, Non

1

-

-

... More
Supply and laying of 120 mm dia (OD-120 mm and ID-103 MM Nominal) HDPE pipe (duly ISI Marked) under ground in trenches in horizontal direction across the road, as per direction of Engineer-In-Charge including jointing of pipe, cleaning etc., providing suitable covers on mouth of pipes, excavation of pits of required size at a depth of 0.3 meters to .5 meters etc. complete as

200

-

-

... More
SITC of 5HP borewell Submersible pump set with necessary fitting Mounts

1

-

-

... More
SITC Of 3` brass gate Valve with proper fittings

4

-

-

... More
SITC of 2`X2`X1` gate valve pit with cover as per Standard

4

-

-

... More
SITC of 1 HP mud submersible pump with 100ft hose pipe

2

-

-

... More
1C x 10 sqmm earthing Cable

500

-

-

... More
Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.(HSR-2023-Cable Laying and Street Lightingitem no-24.1.4)

4

-

-

... More
Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.(HSR-2023-Cable Laying and Street Lightingitem no-24.1.10)

18

-

-

... More
PDB for power distribution in different panel

1

-

-

... More
100 mm dia PVC (HSR-2023-Basic Rate of Materials-B0241)

174

-

-

... More
PVC Bend 100 dia (HSR-2023-Basic Rate of Materials-B0239)

12

-

-

... More
2`PVC Pipe

124

-

-

... More
2`PVC Elbow

16

-

-

... More
2` PVC Tee

40

-

-

... More
Supply and Laying of 90 mm 10kg PVC Pipe boring to fountain pole complete with 10 kg PVC Fitting ,Elbow ,Tee ,MTA Accsessories as per site condition work includes trenching fixing of pipe and covering as per the the direction of Engineer -incharge

1

-

-

... More
Electrical Installations , Fire Fighting Detection and Alarm System COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group A(HSR-2023-. Electrical Installations , Fire Fighting Detection and Alarm System- 23.1)

4

-

-

... More
Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm). (HSR-2023-. Electrical Installations , Fire Fighting Detection and Alarm System-23.6.3)

10

-

-

... More
Supply Installation testing and commissionin of 1.5 tonne 5 star rated split AC complete in all respect and as directed by engineer in charge

2

-

-

... More
Water Supply NA CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 56` (1400mm) (HSR-2023-Water supply item no-20.71/2)

1

-

-

... More
Supply installation testing and commssioning of the ceiling fan with the following specifications: i. Sweep: 1400mm ii. Minimum RPM: 300 iii. Power consumption: 75w Complete in all respects and as directed by engineer in charge

1

-

-

... More
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 12 way ( 2 incoming and 10 outgoing) (HSR-2023-. Electrical Installations , Fire Fighting Detection and Alarm System-23.22/4.3)

1

-

-

... More
SP MCB 6-32 A (HSR-2023-Basic Rate of Materials-EL115)

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.