If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Faridabad Metropolitan Development Authority - FMDA Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Aug 2024
Closing Date25 Sep 2024
Tender Amount₹ 18,82,49,902 
Notes
Download

Costs

Summary

Providing Stadium Lighting In Athletic Ground, Football Ground, Hockey Ground, Skating Rink And Basket Ball Court At Sports Complex Sector-12, Faridabad And All Other Works Contingent Thereto Including 03 Year Oandm Period.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply testing and Laying of following sizes 1.1 KV FRLS XLPE insulated cable with copper/AL conductor, PVC inner sheathed, armoured/unarmoured, overall PVC sheathed stranded and twisted cable in conformity to the technical specification and as per latest IS - codes. 3.5C X 120 Sq.mm. armoured AL

700

-

-

... More
Supply testing and Laying of following sizes 1.1 KV FRLS XLPE insulated cable with copper/AL conductor, PVC inner sheathed, armoured/unarmoured, overall PVC sheathed stranded and twisted cable in conformity to the technical specification and as per latest IS - codes. 3.5C X 185 Sq.mm. armoured AL

1500

-

-

... More
Termination:- 3C X 2.5Sq.mm. unarmoured

272

-

-

... More
Termination:- 3C X 4Sq.mm. unarmoured

272

-

-

... More
Termination:- 3.5C X 120 Sq.mm. armoured AL

10

-

-

... More
Termination:- 3.5C X 185 Sq.mm. armoured AL

2

-

-

... More
Supply and laying 25mm MS flexibale conduit

300

-

-

... More
Supply, Installation, testing and commissioning of 35m Hot dip galvanised, polygonal high masts with fixed head frame/cross arms suitable for mounting up to 32 nos of flood Light (as per above specs) complete with all accessories as per specification.The lights shall be mounted on top surface of each crossarm only.Hanging type mounting of LED lights is to be avoided The height of the mast from base to TOP of head frame shall be 30mtrs. Polygonal high mast tower with fixed head frame along with provision for using manrider (speed should be approx 9m/Min) for accessing the head frame platform. Structural design of the high mast should be carried out as per the technical report no.7/ relevent standard and regulation.The mast should be designed considering base gust wind speed of 47m/s or as per IS 875 and thickness of  GI coating should withstand at the speed of 39m/s. Price shall include suitable 1.2m Lightning Arrestor as per requirement and 2 nos of LED Aviation Light.

4

-

-

... More
Design and Casting of suitable foundation for the 30m high mast as per with specification given above.The foundation has to be designed as per safe soil bearing capacity of 10T/sqm or customer should provide the SBC report for the designing . The foundation shall be designed for wind pressure, earth quake and other loadings as per latest IS code of practice. Design, supply and casting of suitable shallow foundation with M-25 concrete for the High mast considering safe soil bearing capacity at the site.

16

-

-

... More
Supply, Installation, Testing and Commissioning of external manrider unit for accessing the head frame of High Mast. The unit shall be suitable for safe load carrying capacity of 300kg with climb speed not exceeding 9m/min.

1

-

-

... More
`Supply ,Installation, testing and commissioning of IP 55 cubicle type High mast Lighting Panel suitable for 415 volt, 3 phase, 4 wire 50 HZ AC supply system, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland platees, including cleaning and finishing complete with 7 tank process having extensible type TPN aluminium alloy bus bar of high conductivity, with base frame of M.S. section of suitable size, copper earth bar of size 25mmx 5mm at the rear with 2 nos earth stud, complete with control wire, cable alleys, cable gland plates, including following items mentioned below. The panel should be suitable for Pedestrail mounting type 500mm above ground level with necessary base frame. The panels shall be designed for minimum expected ambient temperature of 52 degree Celsius, 100 percent relative humidity and dusty weather. INCOMER:- 1250A Change Over Switch 1 No. 500A, TPN ACB (25kA) with thermo magnetic releases and all required accessories. 1 Set phase indication lights (R, Y, B) Solid state type (LED) 1 No. 0 to 500V, AC, Volt Meter with VSS and control fuses. 1 No. 0 to 500A, Ammeter with ASS andCT`s. class-1 accuracy.  Auto Manual Switch BUS BARS:-700A 4 wire 3 phase 55KA Aluminium bus bars OUT GOINGS:-5 Nos. 100A TPN MCCB (15kA) with thermo-magnetic releases.`

1

-

-

... More
` Supply ,Installation, testing and commissioning of IP 55 cubicle type High mast Lighting Panel suitable for 415 volt, 3 phase, 4 wire 50 HZ AC supply system, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland platees, including cleaning and finishing complete with 7 tank process having extensible type TPN aluminium alloy bus bar of high conductivity, with base frame of M.S. section of suitable size, copper earth bar of size 25mmx 5mm at the rear with 2 nos earth stud, complete with control wire, cable alleys, cable gland plates, including following items mentioned below. The panel should be suitable for Pedestrail mounting type 500mm above ground level with necessary base frame. The panels shall be designed for minimum expected ambient temperature of 52 degree Celsius, 100 percent relative humidity and dusty weather.  INCOMER:-1 No. 100A, TPN MCCB (15kA) with thermo magnetic releases and all required accessories. 1 Set phase indication lights (R, Y, B) Solid state type (LED) 1 No. 0 to 500V, AC, Volt Meter with VSS and control fuses. 1 No. 0 to 100A, Ammeter with ASS andCT`s. of ratio 100/5A and class-1 accuracy.  Auto Manual Switch BUS BARS:-200A 4 wire 3 phase 35KA Aluminium bus bars OUT GOINGS:-4Nos plus 1 Nos Spare . 32 TPN MCCB (10kA) with thermo-magnetic releases. 4 Nos plus 1 Nos Spare 40A, TP Power Contactors. 4 Nos plus 1 Nos Spare ON Time delay relays. 32 nos. 20A SPN MCB - for flood light control 1 nos. 10A SPN MCB - for Aviation Light  1 nos. 10A SPN MCB - for Aviation Light (Spare) 1 No. 32A 4P MCB for Manrider.`

4

-

-

... More
Supplaying, installation, testing and commissioning of rack for installing the 32 No. Drivers (120mm(h) X 500mm(L) X 145mm (D)-6.5kg with proper arrangement of cable laying complete as required.

4

-

-

... More
Supply and laying of Chemical/Maintenance free Earthing with complete accessories

93

-

-

... More
Providing and fixing 25 mm X 3 mm G.I. strip from earth electrode, as required.

320

-

-

... More
Supply, Installation, testing and commissioning of Integral LED flood light of with system wattage of 820W (±10W) (@full load) made of Single piece Aluminium pressure die cast housing (The luminaire shall employ all the LED compartments within in one single piece housing and the product should not be an amalgamation of multiple luminaires joined together mechanically.), recyclable non corrosive, resistance to mechanical strength and vibration caused by winds must have gone through the 500hrs marine salt test protection powder coating. Luminaire and Driver should be on same make in order to maintain the compatibility. Solution comprising of multiple lower wattage Luminaire mounted/clubbed together shall not be accepted. Ingress protection must be with a silicon gasket, glue free, against water ingress to endure higher endurability. Nominal voltage range of 220V-240V having system lumen output at Ta=35°c of =100000lm to meet the desired lux level as per the tender requirement having Luminaire system efficacy of =125Lumen/watt and Driver efficiency at =85%, providing CRI=70, CCT 5700°K, THD =20%, SDCM =5. The same luminaire shall be available with minimum 7 different beam angles including variants in asymmetric beam angle. The luminaire shall be suitable for working in ambient temp of -10 to plus 55 degree centigrade (IEC60598). The luminaire must be having Class 1 Electrical insulation, IP66 ingress and IK08 impact protection, Power factor =.95 at full load. Fixture must have life class of 50000 burning hour as per L70B50 at Ta 35c. The nominal Luminaire weight must be between 27KG (±5%), LED make used in the product should be from Signify (Philips), Nichia, Osram. LEDs used shall only be High Power ceramic based single chip 3V LED with silicone dome and typical wattage of LED chip 3W Max, LED efficacy =150Lm/W at If= 700 mA: TJ = 85 °C. Fixture must comply to below standards for different mentioned parameters IEC61347-1 (Driver safety), LED Drivers should have High voltage protection, 440V protection for 8 hr and shall have in-built surge protection of 4KV. The driver shall be potted using Ashphalt / combination of Ashphalt and silicon, EMI/EMC compliant as per IEC-61547. The luminaire should have 10KV/5KA SPD, should be able to sustain minimum 15 hits of 5KA rating that is total of 45 hits across all the three modes as per IEEE62.41.2. The luminaire driver and It’s SPD shall be of the same make/manufacturer/lighting company as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 Standard, Type test as per IS10322, `FAT` before dispatch as per IS 10322 and IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire and it`s driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire and Driver. Similar to above Specs in Signify (Philips/Ecolink), Regent/Endo/Bajaj/Abacus.

248

-

-

... More
`Supply and laying of following sizes 1.1 KV FRLS XLPE insulated cable with copper conductor, PVC inner sheathed, overall PVC sheathed stranded and twisted cable in conformity to the technical specification and as per latest IS - codes. Supply and laying 3CX 2.5sqmm unarmoured CU cable (For Fixed mast)`

13000

-

-

... More
`Supply and laying of following sizes 1.1 KV FRLS XLPE insulated cable with copper conductor, PVC inner sheathed, overall PVC sheathed stranded and twisted cable in conformity to the technical specification and as per latest IS - codes. Supply and laying 3CX 25sqmm Armoured AL cable`

3200

-

-

... More
`Supply and laying of following sizes 1.1 KV FRLS XLPE insulated cable with copper conductor, PVC inner sheathed, overall PVC sheathed stranded and twisted cable in conformity to the technical specification and as per latest IS - codes. Supply and laying 3.5CX 70sqmm armoured AL cable`

2900

-

-

... More
Termination: - 3CX 2.5sqmm unarmoured CU cable

768

-

-

... More
Termination: - 3CX 25sqmm Armoured AL cable

40

-

-

... More
Termination: - 3.5CX 70sqmm armoured AL cable

8

-

-

... More
Supply, Installation, testing and commissioning of 30M (Top Height Including Head Frame) Hot dip galvanised, polygonal high masts with fixed head frame/cross arms suitable for mounting of up to 22 No’s of LED Flood lights aper tender specifications. The height of the mast from base to top of head frame shall be 30M. Structural design of the high mast should be carried out as per the technical report no.7/ relevant standard and regulation. The mast should be designed considering base gust wind speed of 47m/s or as per IS 875 and thickness of GI coating should withstand at the speed of 39m/s. Price shall include suitable 1.2M Lightning Arrestor as per requirement and 2 No’s of LED Aviation Light. (GI or PU painted). Mast should have monkey ladder for accessing the platform for maintaining the luminaires.

12

-

-

... More
`Supplaying, installation, testing and commissioning of IP 55 cubicle type High mast Lighting Panel suitable for 415 volt, 3 phase, 4 wire 50 HZ AC supply system, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland platees, including cleaning and finishing complete with 7 tank process having extensible type TPN aluminium alloy bus bar of high conductivity, with base frame of M.S. section of suitable size, copper earth bar of size 25mmx 3mm at the rear with 2 nos earth stud, complete with control wire, cable alleys, cable gland plates, including following items mentioned below.  INCOMER:-1 No. 63A, TPN MCCB (15kA) with thermo magnetic releases and all required accessories. 1 Set phase indication lights (R, Y, B) Solid state type (LED) 1 No. 0 to 500V, AC, Volt Meter with VSS and control fuses. 1 No. 0 to 100A, Ammeter with ASS andCT`s. of ratio 100/5A and class-1 accuracy.  Auto Manual Switch BUS BARS:-100A 4 wire 3 phase 35KA Aluminium bus bars OUT GOINGS:-3Nos plus 1 Nos Spare . 32A TPN MCB (10kA) with thermo-magnetic releases. 22 Nos 20 A SPN MCB for flood light 2 nos. 10A SPN MCB - for Aviation Light  1 nos. 10A SPN MCB - for Aviation Light (Spare)`

13

-

-

... More
`supply ,Installation, testing and commissioning of IP 55 cubicle type High mast Lighting Panel suitable for 415 volt, 3 phase, 4 wire 50 HZ AC supply system, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland platees, including cleaning and finishing complete with 7 tank process having extensible type TPN aluminium alloy bus bar of high conductivity, with base frame of M.S. section of suitable size, copper earth bar of size 25mmx 5mm at the rear with 2 nos earth stud, complete with control wire, cable alleys, cable gland plates, including following items mentioned below. The panel should be suitable for Pedestrail mounting type 500mm above ground level with necessary base frame. The panels shall be designed for minimum expected ambient temperature of 52 degree Celsius, 100 percent relative humidity and dusty weather.  INCOMER:-1 No. 150A, TPN MCCB (55kA) with thermo magnetic releases and all required accessories. 1 Set phase indication lights (R, Y, B) Solid state type (LED) 1 No. 0 to 500V, AC, Volt Meter with VSS and control fuses. 1 No. 0 to 150A, Ammeter with ASS andCT`s. of ratio 150/5A and class-1 accuracy.  Outgoing 4 Nos. 63A TPN MCCB (15kA) with thermo-magnetic releases.`

3

-

-

... More
Digging ,chiping and trenching at site for the cable laying to high mast Panel and main LT panel asper site requirement complete with all acceessories.

4

-

-

... More
Supply, Installation, testing and commissioning of high-quality integrated LED Flood Light with a minimum system lumen of 52800lm and system wattage not exceeding 470W (±2%) with a nominal system efficacy =110 lumen/watt. The housing should be of non-corrosive high-pressure single piece pressure die-cast aluminium to withstand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF = 0.95. Lifetime of 75K hours @L70 at 35deg C ambient temperature. Product should be suitable for continuous operation (10-12 Hrs. per day). The luminaire shall be IP66 and IK08 compliant. Driver/SPD shall be maintainable/replaceable without accessing the LED compartment. The luminaire shall employ potted drivers. The potting shall be done using asphalt or combination of asphalt and silicon. The input voltage range for driver shall be 120-277V AC. The luminaire shall be powered using 0-10V analogue dimmable driver having THD=10% (@full load), PF = 0.95 (@full load), In-built surge protection of 4KV. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown/cut-off at less than 90V and 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 and IEC 61000-3-2. The driver shall be EMI/EMC Complied as per EN55015/CISPR15.The Luminaire should have a 20 KV /10 KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire must have a breather. The luminaire should be of Class B Serviceability. The LEDs used shall be SMD type and Ceramic Base High Power LEDs (COB type LED chip is not acceptable. MultiChip LED arrays is not acceptable), Individual LED wattage shall be =1W and = 3W. The LED efficacy shall be = 130lumens/watt (at design operating current and Tj: 85deg C.), CCT: 5700°K, CRI=90 and SDCM = 5. The Luminaire life shall be 50000 Hrs @ Ta35°C. It shall operate at an operating temperature range of -10° to plus 55°C. The Dimension of the luminaires should be minimum W:538mm (Only housing) x L:418mm X Depth: 100mm with fins. The nominal weight of the luminaire should be minimum 12KG and projected area of 0.22sq.mt. The luminaire driver and it’s SPD shall be of the same make/manufacturer/Lighting company as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, `FAT` before dispatch as per IS 10322 and IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer within 15 days of award of LOI. The LED Luminaire and it`s driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approval: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, IK Test report for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire and Driver.

28

-

-

... More
SITC of 12M GI Octagonal Pole with Top dia of 90mm , bottom dia 240mm, sheet thickness 3MM. The base plate shall be 320mmx320mmx20mm. Pole shall be Hot Dip Galvanised as per IS 2629/IS4759. Pole material Oct Pole Hot Rolled M.S. PL. Equivalent or BSEN 10025 GR. S355/IS 2062, GR.- E350,A. Base Plate material shall be as per IS 2062 GR. 250A. The poles shall be designed for life of 25 years. The Pole shall be in one section and shall have single longitudinal welding joint. The pole shall be supplied with a suitable static bracket to mount 10 No`s of aforesaid flood lights.

4

-

-

... More
Design and construction of Casting of suitable foundation for the above pole considering teh SBC of 10T/sq.mt. The foundation shall be designed for wind pressure, earth quake and other loadings as per latest IS code of practice.

4

-

-

... More
Supply, installation, testing and commissioning of 25 MM MS flexibale conduit

450

-

-

... More
Design constrcut to improve entrance gate of the sports complex, providing facade lights, providing and repair street lights on the roads/ paths inside the sports complex. Note: Design for the entrance and façade lighting shall be got approved by FMDA.

1

-

-

... More
Operation and Maintenance

36

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.