Directorate Of Urban Local Bodies Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Directorate Of Urban Local Bodies - DULB Tender

Works
Electrical Cables And Wires
Healthcare and Medicine
Security and Emergency Services
Electrical and Electronics
Eprocure
Opening Date11 Jan 2025
Closing Date3 Feb 2025
Tender Amount₹ 16,26,51,209 
Notes
Download

Costs

  • EMD

    ₹ 32,53,025
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 1,180

Summary

Public Health Services,electrical, Hvac And Firefighting Balance Works For Redevlopment Of Shree Mata Sheetla Devi Shrine Campus

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Primary Chilled Water Pump Set Supply, erection, testing and commissioning of End Suction back pullout Primary chilled water pump set capable of delivering 600 USGPM of water against 12 Meter head each comprising of the following and complete as per specifications and as required. MR 1.4

3

-

-

... More
Variable Secondary Pumping System Installing, testing and commissioning of variable speed pumping system consisting of Adjustable Frequency Drive (AFD) for each pump, one dedicated microprocessor based Stand Alone Pump Controller housed inside a control cabinet or independently with parallel pumping software duly downloaded and single/ multiple differential pressure sensor/ transmitters as per the site requirement. The entire system alongwith secondary pumps of end suction back pullout Secondary Chilled Water pump set capable of following parameter and complete as per specification and requirement of pump and VFD (it must be sourced from single manufacturer only) to ensure unit responsibility. Necessary factory test certificate for entire system shall be submitted alongwith the equipment. The stand alone pump controller shall be suitable for taking analog inputs from 05 Nos. Sensor/ transmitter. The system shall comprise of the following: MR 1.5

3

-

-

... More
Cooling Tower Supplying, installation, testing and commissioning of CTI certified FRP cooling tower of 9,45,600 K.Cal/Hr heat rejection capacity in single cell construction with FRP water basin, PVC fills with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically and dynamically balanced axial flow type fan-direct driven or driven through reduction gear box with TEFC induction motor, suction screen, make up-quick fill arrangement, overflow and drain connections with necessary valves and suitable inspection ladder, access arrangement for cooling tower interior, cement concrete foundation, steel / masonry supporting structure, anti-vibration mountings, complete as per specifications and as required. Motor efficiency shall be IE3. MR 1.6

3

-

-

... More
FLOOR MOUNTED Treated Fresh Air Handling Unit (TFAHU) `FTAHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9. ` MR 1.70

1

-

-

... More
FLOOR MOUNTED Treated Fresh Air Handling Unit (TFAHU) `FTAHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9. `5000 CFM, 40.0 TR, 8RD Cooling Coil @ 50MMWC SP, MOTOR KW- 2.2 KW MR 1.7.2

1

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 12000 CFM, 24.0 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 5.5 KW MR 1.8

1

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.`10000 CFM, 24.0 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 5.5 KW MR 1.8.2

1

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 10000 CFM, 24.0 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 5.5 KW MR 1.8.3

1

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.`10000 CFM, 22.0 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 5.5 KW MR 1.8.4

1

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.`9500 CFM, 17.0 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 5.5 KW 1.8.5

1

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 9000 CFM, 20.0 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 3.7 KW 1.8.6

1

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 8000 CFM, 19.0 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 3.7 KW 1.8.7

3

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 8000 CFM, 18.0 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 3.7 KW 1.8.8

3

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 7000 CFM, 12.0 TR, 4RD Cooling Coil @ 40MMWC SP, MOTOR KW- 3.7 KW 1.8.10

1

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 6500 CFM, 16.5 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 3.7 KW 1.8.11

2

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 6000 CFM, 12.0 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 3.7 KW 1.8.13

1

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 5500 CFM, 10.0 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 2.2 KW 1.8.14

1

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 5000 CFM, 9.0 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 2.2 KW 1.8.15

2

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 4000 CFM, 5.5 TR, 4RD Cooling Coil @ 40MMWC SP, MOTOR KW- 2.2 KW 1.8.16

5

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 3500 CFM, 6.0 TR, 4RD Cooling Coil @ 40MMWC SP, MOTOR KW- 1.5 KW 1.8.20

2

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 3000 CFM, 5.5 TR, 4RD Cooling Coil @ 40MMWC SP, MOTOR KW- 1.5 KW 1.8.22

1

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 2500 CFM, 5.0 TR, 4RD Cooling Coil @ 40MMWC SP, MOTOR KW- 1.1 KW Complete in all respect as per the directions of the Engineer-in-Incharge 1.8.23

4

-

-

... More
Ceiling Suspended Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9.` 2000 CFM, 4.0 TR, 4RD Cooling Coil @ 40MMWC SP, MOTOR KW- 1.1 KW Complete in all respect as per the directions of the Engineer-in-Incharge 1.28

7

-

-

... More
Floor Mounted Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9. ` 19000 CFM, 43.0 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 9.3 KW Complete in all respect as per the directions of the Engineer-in-Incharge 9.1

1

-

-

... More
Floor Mounted Air Handling Unit `AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside and 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 and Filter Bypass leakge F9. ` 10000 CFM, 30.0 TR, 6RD Cooling Coil @ 40MMWC SP, MOTOR KW- 7.5 KW Complete in all respect as per the directions of the Engineer-in-Incharge 9.2

1

-

-

... More
Hydonic Cassette Unit (HCU) Supply, installation, testing and commissioning of ceiling suspended Cassette type Unit complete with casing, filter, cooling coil and multiblade centrifugal direct driven fan (three speed) with TEFC motor of class `F` insulation, operated on 230 volts, single phase, 50Hz, AC supply, external decorative grill/panel, inbuilt drain pump, electrical and control copper cabling from nearest power point complete as required and as per specification of following capacities : Complete in all respect as per the directions of the Engineer-in-Incharge 10.1

1

-

-

... More
Hydonic Cassette Unit (HCU) Supply, installation, testing and commissioning of ceiling suspended Cassette type Unit complete with casing, filter, cooling coil and multiblade centrifugal direct driven fan (three speed) with TEFC motor of class `F` insulation, operated on 230 volts, single phase, 50Hz, AC supply, external decorative grill/panel, inbuilt drain pump, electrical and control copper cabling from nearest power point complete as required and as per specification of following capacities : 2.0 TR, 800 CFM with 3 Row Cooling Coils Complete in all respect as per the directions of the Engineer-in-Incharge 10.2

6

-

-

... More
Hydonic Cassette Unit (HCU) Supply, installation, testing and commissioning of ceiling suspended Cassette type Unit complete with casing, filter, cooling coil and multiblade centrifugal direct driven fan (three speed) with TEFC motor of class `F` insulation, operated on 230 volts, single phase, 50Hz, AC supply, external decorative grill/panel, inbuilt drain pump, electrical and control copper cabling from nearest power point complete as required and as per specification of following capacities : 2.5 TR, 1000 CFM with 3 Row Cooling Coils Complete in all respect as per the directions of the Engineer-in-Incharge 10.3

2

-

-

... More
Hydonic Cassette Unit (HCU) Supply, installation, testing and commissioning of ceiling suspended Cassette type Unit complete with casing, filter, cooling coil and multiblade centrifugal direct driven fan (three speed) with TEFC motor of class `F` insulation, operated on 230 volts, single phase, 50Hz, AC supply, external decorative grill/panel, inbuilt drain pump, electrical and control copper cabling from nearest power point complete as required and as per specification of following capacities : 3.0 TR, 1200 CFM with 3 Row Cooling Coils Complete in all respect as per the directions of the Engineer-in-Incharge 10.4

4

-

-

... More
Fan Coil Unit (FCU) Supply, Installation ,testing and commissioning of fan coil units having following capacities, ceiling mounted complete with insulated body, coil section having chilled water cooling coils with mechanically bonded aluminium fins - dry metallic / synthetic washable fitter, cordless remote, insulated S.S.. drain pan, drain connection, blower,TEFC slow speed ( 3 speed ) squirrel cage induction motor suitable for operation on 230 volts, single phase .50 Hz, A.C. supply. 2.0 TR, 800 CFM with 3 Row Cooling Coils Complete in all respect as per the directions of the Engineer-in-Incharge 11.1

1

-

-

... More
Fan Coil Unit (FCU) Supply, Installation ,testing and commissioning of fan coil units having following capacities, ceiling mounted complete with insulated body, coil section having chilled water cooling coils with mechanically bonded aluminium fins - dry metallic / synthetic washable fitter, cordless remote, insulated S.S.. drain pan, drain connection, blower,TEFC slow speed ( 3 speed ) squirrel cage induction motor suitable for operation on 230 volts, single phase .50 Hz, A.C. supply. 2.5 TR, 1000 CFM with 3 Row Cooling Coils Complete in all respect as per the directions of the Engineer-in-Incharge 11.2

1

-

-

... More
Fan Coil Unit (FCU) Supply, Installation ,testing and commissioning of fan coil units having following capacities, ceiling mounted complete with insulated body, coil section having chilled water cooling coils with mechanically bonded aluminium fins - dry metallic / synthetic washable fitter, cordless remote, insulated S.S.. drain pan, drain connection, blower,TEFC slow speed ( 3 speed ) squirrel cage induction motor suitable for operation on 230 volts, single phase .50 Hz, A.C. supply. 3.0 TR, 1200 CFM with 3 Row Cooling Coils Complete in all respect as per the directions of the Engineer-in-Incharge 11.3

2

-

-

... More
Tube Axial Flow Fans for Emergency Mode (Exhaust Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, H-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. 22000 CFM @ 25 MMWG SP, Motor 11KW Complete in all respect as per the directions of the Engineer-in-Incharge 12.1

1

-

-

... More
Tube Axial Flow Fans for Emergency Mode (Exhaust Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, H-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. 20000 CFM @ 30 MMWG SP, Motor 11KW Complete in all respect as per the directions of the Engineer-in-Incharge 12.2

1

-

-

... More
Tube Axial Flow Fans for Emergency Mode (Exhaust Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, H-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. 19000 CFM @ 25 MMWG SP, Motor 7.5KW Complete in all respect as per the directions of the Engineer-in-Incharge 12.3

1

-

-

... More
Tube Axial Flow Fans for Emergency Mode (Exhaust Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, H-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. 14500 CFM @ 25 MMWG SP, Motor 7.5KW Complete in all respect as per the directions of the Engineer-in-Incharge 12.4

1

-

-

... More
Tube Axial Flow Fans for Emergency Mode (Exhaust Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, H-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. 12000 CFM @ 25 MMWG SP, Motor 4.0KW Complete in all respect as per the directions of the Engineer-in-Incharge 12.5

1

-

-

... More
Tube Axial Flow Fans for Emergency Mode (Exhaust Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, H-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. 11000 CFM @ 25 MMWG SP, Motor 4.0KW Complete in all respect as per the directions of the Engineer-in-Incharge 12.7

2

-

-

... More
Tube Axial Flow Fans for Emergency Mode (Exhaust Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, H-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. 9500 CFM @ 25 MMWG SP, Motor 3.0KW Complete in all respect as per the directions of the Engineer-in-Incharge 12.7

2

-

-

... More
Tube Axial Flow Fans for Emergency Mode (Exhaust Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, H-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. 8000 CFM @ 25 MMWG SP, Motor 3.0KW Complete in all respect as per the directions of the Engineer-in-Incharge 12.8

1

-

-

... More
Tube Axial Flow Fans for Emergency Mode (Exhaust Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, H-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. 7500 CFM @ 25 MMWG SP, Motor 3.0KW Complete in all respect as per the directions of the Engineer-in-Incharge 12.9

2

-

-

... More
Tube Axial Flow Fans for Emergency Mode (Exhaust Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, H-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. 7000 CFM @ 25 MMWG SP, Motor 3.0KW Complete in all respect as per the directions of the Engineer-in-Incharge 12.10

1

-

-

... More
Tube Axial Flow Fans for Emergency Mode (Exhaust Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, H-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Normal Case 2000 CFM @ 25 MMWG SP, Motor 0.75KW Complete in all respect as per the directions of the Engineer-in-Incharge 12.11

2

-

-

... More
Tube Axial Flow Fans for Emergency Mode (Exhaust Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, H-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Normal plus Emergency Case 12000 CFM @ 30 MMWG SP, Motor 5.5KW Complete in all respect as per the directions of the Engineer-in-Incharge 12.12

1

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Emergency Case 22000 CFM @ 25 MMWG SP, Motor 11KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.1

1

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Emergency Case 20000 CFM @ 30 MMWG SP, Motor 11KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.2

1

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Emergency Case 19000 CFM @ 25 MMWG SP, Motor 7.5KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.3

1

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Emergency Case 14500 CFM @ 25 MMWG SP, Motor 7.5KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.4

1

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Emergency Case 12000 CFM @ 25 MMWG SP, Motor 4.0KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.5

1

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Emergency Case 11000 CFM @ 25 MMWG SP, Motor 4.0KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.6

1

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Emergency Case 9500 CFM @ 25 MMWG SP, Motor 3.0KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.7

2

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Emergency Case 8000 CFM @ 25 MMWG SP, Motor 3.0KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.8

1

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Emergency Case 7500 CFM @ 25 MMWG SP, Motor 3.0KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.9

2

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Emergency Case 7000 CFM @ 25 MMWG SP, Motor 3.0KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.10

1

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Normal Case 2000 CFM @ 25 MMWG SP, Motor 2.0KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.11

2

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Normal plus Emergency Case 14000 CFM @ 30 MMWG SP, Motor 5.5KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.12

1

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Pressurization 10500 CFM @ 40 MMWG SP, Motor 5.5KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.13

1

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Pressurization 9000 CFM @ 40 MMWG SP, Motor 5.5KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.14

1

-

-

... More
Tube Axial Flow Fans for Normal and Emergency Mode (Fresh Air) Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance and sound ratings and the fan should be selected for maximum efficiency. Pressurization 5500 CFM @ 40 MMWG SP, Motor 5.5KW Complete in all respect as per the directions of the Engineer-in-Incharge 13.15

9

-

-

... More
Ducted Inline Fans Supply, installation, testing and commissioning of INLINE FANS suitable for installing in any position in vertical or horizontal ducts. The casing shall be double skin, internally acoustically lined and constructed of galvanised steel. The fan shall be DIDW with forward curve impeller fitted with maintenance free external rotor motor. The motor shall be suitable for 220±10% volt single phase 50 cycles AC supply. Quoted price shall be inclusive of electronic speed regulator and wiring between fan and speed regulator for single phase fans. Incase of 3 phase fans quated price shall be inclusive of DOL starter panel with cabling between starter panel and fan. The incoming power supply to speed regulator / starter panel shall be provided by electrical contractor. The fan shall have low sound level exceeding not more than 40 DBA at three metre distance. 1600 CFM @ 15 MMWG Static Pressure Complete in all respect as per the directions of the Engineer-in-Incharge 15.1

2

-

-

... More
Ducted Inline Fans Supply, installation, testing and commissioning of INLINE FANS suitable for installing in any position in vertical or horizontal ducts. The casing shall be double skin, internally acoustically lined and constructed of galvanised steel. The fan shall be DIDW with forward curve impeller fitted with maintenance free external rotor motor. The motor shall be suitable for 220±10% volt single phase 50 cycles AC supply. Quoted price shall be inclusive of electronic speed regulator and wiring between fan and speed regulator for single phase fans. Incase of 3 phase fans quated price shall be inclusive of DOL starter panel with cabling between starter panel and fan. The incoming power supply to speed regulator / starter panel shall be provided by electrical contractor. The fan shall have low sound level exceeding not more than 40 DBA at three metre distance.1500 CFM @ 15 MMWG Static Pressure Complete in all respect as per the directions of the Engineer-in-Incharge 14.2

1

-

-

... More
Supply, installation, testing and commissioning of INLINE FANS suitable for installing in any position in vertical or horizontal ducts. The casing shall be double skin, internally acoustically lined and constructed of galvanised steel. The fan shall be DIDW with forward curve impeller fitted with maintenance free external rotor motor. The motor shall be suitable for 220±10% volt single phase 50 cycles AC supply. Quoted price shall be inclusive of electronic speed regulator and wiring between fan and speed regulator for single phase fans. Incase of 3 phase fans quated price shall be inclusive of DOL starter panel with cabling between starter panel and fan. The incoming power supply to speed regulator / starter panel shall be provided by electrical contractor. The fan shall have low sound level exceeding not more than 40 DBA at three metre distance. Complete in all respect as per the directions of the Engineer-in-Incharge 1000 CFM @ 15 MMWG Static Pressure 14.3

1

-

-

... More
Ducted Inline Fans Supply, installation, testing and commissioning of INLINE FANS suitable for installing in any position in vertical or horizontal ducts. The casing shall be double skin, internally acoustically lined and constructed of galvanised steel. The fan shall be DIDW with forward curve impeller fitted with maintenance free external rotor motor. The motor shall be suitable for 220±10% volt single phase 50 cycles AC supply. Quoted price shall be inclusive of electronic speed regulator and wiring between fan and speed regulator for single phase fans. Incase of 3 phase fans quated price shall be inclusive of DOL starter panel with cabling between starter panel and fan. The incoming power supply to speed regulator / starter panel shall be provided by electrical contractor. The fan shall have low sound level exceeding not more than 40 DBA at three metre distance. Complete in all respect as per the directions of the Engineer-in-Incharge 800 CFM @ 15 MMWG Static Pressure 14.4

1

-

-

... More
Ducted Inline Fans Supply, installation, testing and commissioning of INLINE FANS suitable for installing in any position in vertical or horizontal ducts. The casing shall be double skin, internally acoustically lined and constructed of galvanised steel. The fan shall be DIDW with forward curve impeller fitted with maintenance free external rotor motor. The motor shall be suitable for 220±10% volt single phase 50 cycles AC supply. Quoted price shall be inclusive of electronic speed regulator and wiring between fan and speed regulator for single phase fans. Incase of 3 phase fans quated price shall be inclusive of DOL starter panel with cabling between starter panel and fan. The incoming power supply to speed regulator / starter panel shall be provided by electrical contractor. The fan shall have low sound level exceeding not more than 40 DBA at three metre distance. Complete in all respect as per the directions of the Engineer-in-Incharge 500 CFM @ 15 MMWG Static Pressure 14.5

2

-

-

... More
Ducted Inline Fans Supply, installation, testing and commissioning of INLINE FANS suitable for installing in any position in vertical or horizontal ducts. The casing shall be double skin, internally acoustically lined and constructed of galvanised steel. The fan shall be DIDW with forward curve impeller fitted with maintenance free external rotor motor. The motor shall be suitable for 220±10% volt single phase 50 cycles AC supply. Quoted price shall be inclusive of electronic speed regulator and wiring between fan and speed regulator for single phase fans. Incase of 3 phase fans quated price shall be inclusive of DOL starter panel with cabling between starter panel and fan. The incoming power supply to speed regulator / starter panel shall be provided by electrical contractor. The fan shall have low sound level exceeding not more than 40 DBA at three metre distance. Complete in all respect as per the directions of the Engineer-in-Incharge 400 CFM @ 15 MMWG Static Pressure 14.6

1

-

-

... More
Ducted Inline Fans Supply, installation, testing and commissioning of INLINE FANS suitable for installing in any position in vertical or horizontal ducts. The casing shall be double skin, internally acoustically lined and constructed of galvanised steel. The fan shall be DIDW with forward curve impeller fitted with maintenance free external rotor motor. The motor shall be suitable for 220±10% volt single phase 50 cycles AC supply. Quoted price shall be inclusive of electronic speed regulator and wiring between fan and speed regulator for single phase fans. Incase of 3 phase fans quated price shall be inclusive of DOL starter panel with cabling between starter panel and fan. The incoming power supply to speed regulator / starter panel shall be provided by electrical contractor. The fan shall have low sound level exceeding not more than 40 DBA at three metre distance. Complete in all respect as per the directions of the Engineer-in-Incharge 200 CFM @ 15 MMWG Static Pressure 14.7

2

-

-

... More
Propeller Fan Supply, installation, testing and commissioning of direct driven PROPELLER FANS for exhaust / supply air as shown in drawings. Each fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate, accessories like wire guard, bird screen and fixed louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows : Complete in all respect as per the directions of the Engineer-in-Incharge 250 mm dia 900 RPM fan suitable for 220±6% volts 50 cycles, 1 phase AC supply. Make: Airflow/Caryaire/Kruger 15.1

8

-

-

... More
Supply, receiving, storing, inspection, handling, assembling, installation in correct aligned position,effecting proper connections, testing and commisioning of Outdoor type package type substation with continuous rating 800 KVA, Step Down, 11/0.433 kV oil filled ON load tap changer transformer with 4 mm thick base and 2 mm thick wall of each compartment with compartment, with IP 54 for HT and LT compartment and IP 23 for transformer compartment, with naturally cooled type canopy (Hot Galvanized Steel), required capicity power pack and the following specifications confirming to IS: 2026 pack and the following specifications confirming to IS: 2026

1

-

-

... More
Supply, receiving, storing, inspection, handling, assembling, installation in correct aligned position,effecting proper connections, testing and commisioning of Outdoor type package type substation with continuous rating 1000 KVA, Step Down, 11/0.433 kV oil filled ON load tap changer transformer with 4 mm thick base and 2 mm thick wall of each compartment with compartment, with IP 54 for HT and LT compartment and IP 23 for transformer compartment, with naturally cooled type canopy (Hot Galvanized Steel), required capicity power pack and the following specifications confirming to IS: 2026 pack and the following specifications confirming to IS: 2026

1

-

-

... More
Supply, Installation, Testing and Commissioning of Battery Charger Unit with provisions of `Boost Charging` and `Float Charging`, suitable for 240V, single phase, AC, 50Hz supply system and 24V DC including providing required MCB for DC supply distribution to panel complete as required.

2

-

-

... More
Supply and fixing in position the approved `shock treatment charts` framed in teak wood frame and covered with glass in front as required in two languages (Hindi and English)

2

-

-

... More
Supply and fixing of Mimic diagram for overall schematic of power distribution complete as required.

2

-

-

... More
Supply of Rubber hand gloves 11KV grade, as per IS 4770-1968.

4

-

-

... More
Supply of standard first aid box as approved by Indian red cross society/ St.John Ambulance Brigade and conforming to IS 2217-1963.

2

-

-

... More
Supply and laying of following 1100V grade PVC insulated armoured copper conductor control cables as per specification.(For HT Panel controls, Transformer Protection, PLC controls.)including cost of termation. 2C X 2.5sq.mm Cu. Cable

80

-

-

... More
Supply and laying of following 1100V grade PVC insulated armoured copper conductor control cables as per specification.(For HT Panel controls, Transformer Protection, PLC controls.)including cost of termation. 4C X 2.5sq.mm Cu. Cable

60

-

-

... More
Supply and laying of following 1100V grade PVC insulated armoured copper conductor control cables as per specification.(For HT Panel controls, Transformer Protection, PLC controls.)including cost of termation. 10C X 2.5sq.mm Cu. Cable

80

-

-

... More
Supply and laying of following 1100V grade PVC insulated armoured copper conductor control cables as per specification.(For HT Panel controls, Transformer Protection, PLC controls.)including cost of termation. 2C X 1.5sq.mm Cu. Shielded Cable

60

-

-

... More
Supply and laying of 11KV grade cross linked polyethylene (XLPE) armoured, earthed aluminum conductor cables complete as required and as per specification. 3 core X 150 sq. mm

30

-

-

... More
Supply and laying of 11KV grade cross linked polyethylene (XLPE) armoured, earthed aluminum conductor cables complete as required and as per specification. 3 core X 240 sq. mm

300

-

-

... More
Providing and Making cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 33 KV/11KV 3 core XLPE alum. conductor cable as required as per specification and as per accepted standard including connection testing complete. 3 x 150-225 sq. mm.

2

-

-

... More
Providing and Making cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 33 KV/11KV 3 core XLPE alum. conductor cable as required as per specification and as per accepted standard including connection testing complete. 3 x 240-400 sq. mm.

4

-

-

... More
Design, manufacture, supply,including supervision during installation, testing and commissioning of the following extensible cubicle type indoor mounting, dead front, fully compartmentalised with hinged lockable detachable front and back openable, dust and vermin proof, floor mounting sheet steel clad switchboard fabricated out of 2 mm thick CRCA powder coated sheet steel suitable for use at 415 volts 3 phase 4 wire 50 cycle system and to withstand a symmetrical fault level of 50 KA at 415 volts. Panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition. All incomer breaker and Bus Couplers shall be interlocked electrically as shown in SLD and specifications.

1

-

-

... More
Design, manufacture, supply,including supervision during installation, testing and commissioning of 2 mm thick MS sheet steel fabricated cubicle type Panel dust and vermin proof complete with hinged and lockable doors . The Sheet Steel shall under go minimum eight tank treatment followed by finishing treatment of powder coating with 70 micron minimum thickness. All the panels shall be floor mounted and dead front construction complete with interconnections. Protection of Feeder pillar shall be IP55. LIFT PANEL 1

1

-

-

... More
Design, manufacture, supply,including supervision during installation, testing and commissioning of 2 mm thick MS sheet steel fabricated cubicle type Panel dust and vermin proof complete with hinged and lockable doors . The Sheet Steel shall under go minimum eight tank treatment followed by finishing treatment of powder coating with 70 micron minimum thickness. All the panels shall be floor mounted and dead front construction complete with interconnections. Protection of Feeder pillar shall be IP55. LIFT PANEL 2,3,4

3

-

-

... More
Supply and laying of following sizes of 1.1 KV XLPE insulated Aluminium conductor armoured cables complete as required and as per specifications with cost of indoor/outdoor terimantion. 3.5 x 300 sq.mm. Aluminium Cable

2440

-

-

... More
Supply and laying of following sizes of 1.1 KV XLPE insulated Aluminium conductor armoured cables complete as required and as per specifications with cost of indoor/outdoor terimantion. 3.5 x 240 sq.mm. Aluminium Cable

150

-

-

... More
Supply and laying of following sizes of 1.1 KV XLPE insulated Aluminium conductor armoured cables complete as required and as per specifications with cost of indoor/outdoor terimantion. 3.5 x 150 sq.mm. Aluminium Cable

380

-

-

... More
Supply and laying of following sizes of 1.1 KV XLPE insulated Aluminium conductor armoured cables complete as required and as per specifications with cost of indoor/outdoor terimantion. 3.5 x 120 sq.mm. Aluminium Cable

60

-

-

... More
Supply and laying of following sizes of 1.1 KV XLPE insulated Aluminium conductor armoured cables complete as required and as per specifications with cost of indoor/outdoor terimantion. 3.5 x 95 sq.mm. Aluminium Cable

380

-

-

... More
Supply and laying of following sizes of 1.1 KV XLPE insulated Aluminium conductor armoured cables complete as required and as per specifications with cost of indoor/outdoor terimantion. 3.5 x 70 sq.mm. Aluminium Cable

60

-

-

... More
Supply and laying of following sizes of 1.1 KV XLPE insulated Aluminium conductor armoured cables complete as required and as per specifications with cost of indoor/outdoor terimantion. 3.5 x 25 sq.mm. Aluminium Cable

250

-

-

... More
Supply and laying of following sizes of 1.1 KV XLPE insulated Aluminium conductor armoured cables complete as required and as per specifications with cost of indoor/outdoor terimantion. 4C x 16 sq.mm. Aluminium Cable

620

-

-

... More
Supply and fixing fencing of chain link mesh 100 x 100mm, 12 SWG GI wire for electric sub-station switch yard including single post of angle iron size 50x50x5mm, 2.5 mt long should be provided upto 2.00mt. apart or as required with angle iron/ flat iron members/cross members including mesh fix on frame and erected between the post. The angle iron post shall be erected in cement concrete M-15 (1:2:4) (20 mm graded metal) foundation, cement concrete, excavation of pit and refilling the same. The fencing shall be provided with one entrance gate including locking arrangement as required as per specification. The height of fencing shall be 2 mt. above ground level. Fencing shall be painted with required shade.

181

-

-

... More
Supply and installation of maintenance free Chemical Earthing using Electrode of size 23.2 mm dia, 03 meter long connected with 50X6 mm Copper internal strip complete with excavation, civil works, cast iron cover with back fill compound. The voltage between Neutral and Earth not to exceed 0 volts and IR value less than 1 ohm. The earth resistance shall be as per IS 3043

10

-

-

... More
Supply and installation of maintenance free Chemical Earthing using Electrode of size 17.2 mm dia, 03 meter long connected with 25X5 mm Copper internal strip complete with excavation, civil works, cast iron cover with back fill compound. The voltage between Neutral and Earth not to exceed 0 volts and IR value less than 1 ohm. The earth resistance shall be as per IS 3043

16

-

-

... More
Supply and installation of maintenance free Chemical Earthing using Electrode of size 17.2 mm dia, 03 meter long connected with 50X6 mm Copper internal strip complete with excavation, civil works, cast iron cover with back fill compound. The voltage between Neutral and Earth not to exceed 0 volts and IR value less than 1 ohm. The earth resistance shall be as per IS 3043

18

-

-

... More
Supply and laying in position the following GI tape/wires including providing all fixing accessories and effecting proper connections including clamping to wall with suitable clamp / Saddle and fixing bolts / Soldering / rivetting in ground including the cost of digging and back filling as required and complete as required to comply with IS 3043. All joints shall be tinned. 25 x 5 mm GI tape

1000

-

-

... More
Supply and laying in position the following GI tape/wires including providing all fixing accessories and effecting proper connections including clamping to wall with suitable clamp / Saddle and fixing bolts / Soldering / rivetting in ground including the cost of digging and back filling as required and complete as required to comply with IS 3043. All joints shall be tinned. 50 x 6 mm GI tape

50

-

-

... More
Supply and laying in position the following GI tape/wires including providing all fixing accessories and effecting proper connections including clamping to wall with suitable clamp / Saddle and fixing bolts / Soldering / rivetting in ground including the cost of digging and back filling as required and complete as required to comply with IS 3043. All joints shall be tinned. 50 x 6 mm CU tape

100

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connvectors, suspended from the ceiling with G.I. suspenders including G.I. bolts and nuts, etc. as required. 600 mm width X 75 mm X 2.0 mm thickness

55

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connvectors, suspended from the ceiling with G.I. suspenders including G.I. bolts and nuts, etc. as required. 750 mm width X 75 mm X 2.0 mm thickness

190

-

-

... More
Design, manufacturing, testing at works, supply installation, testing and commissioning of DG Set of following rating for site conditions, complete with latest CPCB complient Diesel Engine base frame, lube oil system, Radiator, required batteries, governor, instrumentation, day service fuel tank, exhaust silencers including Aluminium cladding, alarms, engine mounted control panel, utility piping, anti vibration pads, Alternator (Stamford/AVK SEGC) direct coupled to Engine along with static excitation system and AVR panel and all required accessories complete as required and as per specifications.The scope of work does not include AMF panel, cabling and earthing. Cable Box to be provided for termination of required Al. Cable.750 KVA

1

-

-

... More
Design, manufacturing, testing at works, supply installation, testing and commissioning of DG Set of following rating for site conditions, complete with latest CPCB complient Diesel Engine base frame, lube oil system, Radiator, required batteries, governor, instrumentation, day service fuel tank, exhaust silencers including Aluminium cladding, alarms, engine mounted control panel, utility piping, anti vibration pads, Alternator (Stamford/AVK SEGC) direct coupled to Engine along with static excitation system and AVR panel and all required accessories complete as required and as per specifications.The scope of work does not include AMF panel, cabling and earthing. Cable Box to be provided for termination of required Al. Cable.320 KVA

1

-

-

... More
Design, manufacturing, testing at works, supply installation, testing and commissioning of DG Set of following rating for site conditions, complete with latest CPCB complient Diesel Engine base frame, lube oil system, Radiator, required batteries, governor, instrumentation, day service fuel tank, exhaust silencers including Aluminium cladding, alarms, engine mounted control panel, utility piping, anti vibration pads, Alternator (Stamford/AVK SEGC) direct coupled to Engine along with static excitation system and AVR panel and all required accessories complete as required and as per specifications.The scope of work does not include AMF panel, cabling and earthing. Cable Box to be provided for termination of required Al. Cable.200 KVA

1

-

-

... More
Supply, laying and fixing of following sizes of MS B Class piping(Tatas, Jindal (Hissar), IST) with bends etc. for Exhaust of DG Sets including providing suitable self supporting arrangement etc. and supplying and fixing 75 mm thick mineral wool insulation of 150 Kg per cubic meter density on all sides of Exhaust pipe and silencer with chicken mesh wrapping and aluminium cladding with aluminium sheet of 26 SWG,suitable for outdoor installation complete as required and as per specification. (Refer Layout enclosed) The DG Exhaust shall be taken along the building supported from the wall however scope includes building required structure for crossing the ramp.2X200mm NB MS pipes

50

-

-

... More
Supply, laying and fixing of following sizes of MS B Class piping(Tatas, Jindal (Hissar), IST) with bends etc. for Exhaust of DG Sets including providing suitable self supporting arrangement etc. and supplying and fixing 75 mm thick mineral wool insulation of 150 Kg per cubic meter density on all sides of Exhaust pipe and silencer with chicken mesh wrapping and aluminium cladding with aluminium sheet of 26 SWG,suitable for outdoor installation complete as required and as per specification. (Refer Layout enclosed) The DG Exhaust shall be taken along the building supported from the wall however scope includes building required structure for crossing the ramp.1X125mm NB MS pipes

25

-

-

... More
Supply, laying and fixing of following sizes of MS B Class piping(Tatas, Jindal (Hissar), IST) with bends etc. for Exhaust of DG Sets including providing suitable self supporting arrangement etc. and supplying and fixing 75 mm thick mineral wool insulation of 150 Kg per cubic meter density on all sides of Exhaust pipe and silencer with chicken mesh wrapping and aluminium cladding with aluminium sheet of 26 SWG,suitable for outdoor installation complete as required and as per specification. (Refer Layout enclosed) The DG Exhaust shall be taken along the building supported from the wall however scope includes building required structure for crossing the ramp.1X100mm NB MS pipes

25

-

-

... More
Supply and Fixing of miscellaneous structural support for horizontal/ vertical exhaust piping including fabrication, hardwares and painting as per drawing and as per manufacturer recommendation.

2000

-

-

... More
Supplying of 7m GI Octagonal pole provided with 35-55micron Antirust coating and PU (PolyUrethane) Painted, the pole coating includes red oxide and PU synthetic paint coatings in 2 layers. The pole shall be made of 3.0mm thick sheet with 80 mm outer dia with a base plate minimum of 300mm X 300mm, thickness- 15 mm, 2Nos Template and 4 nos of GI. foundation nut and bolt (25mm dia and 250mm long complete asrequired.

30

-

-

... More
Installation of 7m high street light pole including installation of street light fitting (Cost of fitting not to be considered here) with all accessories and supply and making foundation of reinforced cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) including 2Nos. supply and laying of 50mm PVC pipe from ground to terminal box including excavation and refilling, including positioning of template and foundations bolts (supplied with pole to match with pole base plate) complete as required and as specified.

30

-

-

... More
Supplying and fixing of GI Octagonal Single arm decorative design 40 mm dia X 1.0 Meter long provided with 35-55 micron Anti rust coating and PU (PolyUrethane) Painted, the arm coating includes red oxide and PU synthetic paint coatings in 2 layers for mounting of LED street light and flood light fitting including bracket with nuts, bolts and washer for mounting on pole top complete as required.

30

-

-

... More
Supply of 80W LED street light with high pressure die cast Aluminium/ standard alloy/ CRCA housing with Polycarbonate diffuser with integral constant current driver input operating voltage range 150V– 270V 50Hz AC supply, prewired upto the terminal block. System lumen output = 4500 lumens with luminaire efficacy =100 lm/W, lumen maintenance of 70% at the end of 50000 burning hours, CCT of 5700K - 6500K, PF=0.95, CRI=70, THD(10%, surge protection of = 10kv and IP=65 protected with separate optics and control gear compartment, toughened glass protector, permanently sealed and a removable control gear plate, , mounting spigot suitable for horizontal mounting (Ø 32 – 42mm) with tilt flexibility of ( plus )(-) 10 degrees. LED shall have reverse polarity, open and short circuit protection.

30

-

-

... More
Supply of 10W LED Bollard having lumen not less than 855 lumens with luminaire efficacy of not less than 95 lumens per watt, lumen maintenance of 70% at the end of 50000 burning hours with constant current driver output, Power Factor =0.95 and THD (10%, CRI)70,neutral white light and made of GI pipe bottom housing the control gear Speen Aluminium dome shaped type cover with cylindrical dome shaped top cover, overall length of bollard to be minimum of 600 mm, operating range 150V – 270V, 50Hz AC supply, inbuilt driver with surge protection =10KV. The luminaire shall be minimum IP:65 protected. LED shall have reverse polarity, open and short circuit protection.

85

-

-

... More
Supply, Installations, testing and commissioning of 30W LED Post Top Light with high pressure die cast Aluminium/ standard alloy/ CRCA housing with Polycarbonate diffuser with integral constant current driver input operating voltage range 150V – 270V 50Hz AC supply, prewired upto the terminal block. System lumen output = 4500 lumens with luminaire efficacy = 100lm/W, lumen maintenance of 70% at the end of 50000 burning hours, CCT of 5700K - 6500K, PF=0.95, CRI=70, THD(10%, surge protection of = 10kv and IP=65 protected. LED shall have reverse polarity, open and short circuit protection.

120

-

-

... More
Supply, Installation, Testing and Commisioning of 10W LED GATE LIGHT with high pressure die cast aluminium/ standard alloy with Polycarbonate diffuser with integral constant current driver input operating voltage range 150-270 50Hz AC supply, prewired upto the terminal block, IP65 protected.

8

-

-

... More
Supply, installation, testing and commissioning of 8W LED SPIKE LIGHT luminaire with compact, aesthetic, pure polyester powder coated Die cast Aluminium housing and in built electronic driver with 2kV surge protection, 2Way 10 Amps GFP mains connector, high efficiency COB LED mounted on black anodised aluminium heat sink for effective heat dissipation with front maintainable with vandal resistant toughened glass giving access to driver and LED conforms to IS 10322, special high efficiency optical grade UV stabilized engineering plastic reflector, Beam Angle 36°, with a nominal system lumen output of 600 lumens , Power factor 0.9 or higher. The luminaire shall meet IP67 rating.

50

-

-

... More
Supply, laying, testing and commissioning of following size PVC insulated copper conductor 1100 V grade armored cable including excavation sand filling providing brick protection, back filling of earth, watering, ramming and consolidating of earth, complete: 4 x 10 sq.mm. Aluminium Cable

500

-

-

... More
Supply, laying, testing and commissioning of following size PVC insulated copper conductor 1100 V grade armored cable including excavation sand filling providing brick protection, back filling of earth, watering, ramming and consolidating of earth, complete: 3CX1.5 sq.mm. Cu. Un.Ar. Flexible cable

500

-

-

... More
Wiring with 3 x 2.5 sq. mm. PVC insulated copper conductor 1100 V grade wires in existing pole including connecting at the lighting fixtures complete.

1500

-

-

... More
Design, manufacture,Supply, Installation, testing and commissioning at works of Single door panel fabricated with minimum 2mm thick CRCA sheet, Conform to IS Specification, with IP-55 enclosure protection, as per IS-2137(Revised), floor mounting free standing on a suitable massanory pedestal outdoor type panel,provided with hinged detachable and lockable outer opening doors with the following incoming/outgong MCCB/ MCBs mounted therein including making connections/ interconnections, earthing, painting etc. as required.The panel shall have canopy arrangement on the top.All MCB to be C curve .

2

-

-

... More
Ducting Supply, installation, testing, balancing and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Complete in all respect as per the directions of the Engineer-in-Incharge Make: Ductofab/Greenoz/Rolastar Make for GSS Sheet: TATA/Bhushan/SAIL 1.25 mm thick (18 Gauge) 1.1

550

-

-

... More
Ducting Supply, installation, testing, balancing and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Complete in all respect as per the directions of the Engineer-in-Incharge Make: Ductofab/Greenoz/Rolastar Make for GSS Sheet: TATA/Bhushan/SAIL 1.00 mm thick (20 Gauge) 1.2

1050

-

-

... More
Ducting Supply, installation, testing, balancing and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Complete in all respect as per the directions of the Engineer-in-Incharge Make: Ductofab/Greenoz/Rolastar Make for GSS Sheet: TATA/Bhushan/SAIL 0.80 mm thick (22 Gauge) 1.3

1550

-

-

... More
Duct Insulation Supplying , installation, testing and commissioning of external thermal insulation on ducts with Duly laminated aluminum foil of mat finish Closed Cell Cross Linked Polyethylene (class “O”) insulation shall be 27 ± 3 Kg/m3. The product shall have temperature range of –40 oC to 105oC. Thermal Conductive not exceeding 0.033 W/mK at an average Temperature of 23°C. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6 : 1989 for fire propagation test and for Class 0 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability shall be not less than 0.024 per inch (2.48 x 10-14 Kg/m.s.Pa i.e. µ)7000: Water vapour diffusion resistance).The Material shall have Fire Approval from CBRI - Roorkee Complete in all respect as per the directions of the Engineer-in-Incharge 19 mm thick Closed Cell Cross Linked Polyethylene( XLPE) Foam with Factory Laminated Aluminium Foil for Supply Air Duct Makes: Aerolam/Aerofoam/Trocellen 2.1

5705

-

-

... More
Acoustic Lining Supply, Installation, Testing and Commissioning of Acoustic lining inside ducts using Non Fibrous fire retardant crosslinked polyethylene foam of 60 plus /- 3 Kg/m3 density and thickness of 15mm /25mm having porous surface on one side and a flat surface on other side using Synthetic rubber based Adhesive preferably Low VOC and high strength characteristic(Initial portion of ducting and main plenum) as per specifications Complete in all respect as per the directions of the Engineer-in-Incharge 15mm thick ecosound (FR-Open Cell Cross Linked Polyethylene) for supply and return air ducts Makes: Aerolam/Aerofoam/Trocellen 3.1

180

-

-

... More
Continuous Grille Supplying and fixing of powder coated extruded aluminium continuous Griles with louvers but without volume control dampers complete as required.Complete in all respect as per the directions of the Engineer-in-Incharge 100 MM Height 4.1

150

-

-

... More
Continuous Grille Supplying and fixing of powder coated extruded aluminium continuous Griles with louvers but without volume control dampers complete as required.Complete in all respect as per the directions of the Engineer-in-Incharge 150 MM Height

150

-

-

... More
Continuous Grille Supplying and fixing of powder coated extruded aluminium continuous Griles with louvers but without volume control dampers complete as required.Complete in all respect as per the directions of the Engineer-in-Incharge 200 MM Height

200

-

-

... More
Supply, Installation and testing of following type led Compact light fixtures, on wall/ Ceiling including all fixing accessories, etc complete as required. The led shall be complete with Low loss copper driver all prewired upto the terminal block. All fixtures shall be supplied with lamps as required. 5A 12VDC DRIVER FOR PROFILE LIGHT (PHILLIPS)

270

-

-

... More
Supplying and erecting LED circular 15W downlighter Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110lumen/W, CRI)80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD(10%, p.f. )0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

510

-

-

... More
Supplying and erecting LED circular 18W down lighter Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110lumen/W, CRI)80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD(10%, p.f. )0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

1882

-

-

... More
Supply Air Grills Supplying and fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. Complete in all respect as per the directions of the Engineer-in-Incharge

10

-

-

... More
Supplying and erecting LED circular 24W down lighter Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI)80, CCT upto 6500K, Beam Angle of 120 deg, max. ripple of 5%, THD(10%, p.f. )0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

95

-

-

... More
Supplying and erecting LED Panel Light(600mm X 600mm) 30W, having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI)80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD(10%, p.f.)0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

223

-

-

... More
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI)80, CCT upto 6500K, Beam Angle of 120 deg., THD(10%, p.f. )0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.

37

-

-

... More
Return Air Grills Supplying and fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. Complete in all respect as per the directions of the Engineer-in-Incharge

10

-

-

... More
Supplying and erecting anodized aluminium mirror light LED fitting (2 feet) 10W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI)80, CCT upto 6000K, Beam Angle of 110 deg., Ripple(5%, THD(10%, p.f. )0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.

27

-

-

... More
Supply and fixing of recessed mounting 30W LED swivel type COB downlighter, having color temp upto 6500K and having 20000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy)80lm/W. LED driver PF ) 0.9, THD ( 20% and surge protection 5KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium / CRCA powder coated frame with glare free diffused polycorbonate cover. LM79-08 / IS16106 from NABL approved lab. i/c connection wire, testing etc. to complete the job.

229

-

-

... More
Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min and service value = 4.00 as per BEE..

222

-

-

... More
Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, PWM and IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification.

1

-

-

... More
Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete

32

-

-

... More
Supply Air Diffuser Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring and removable core. Complete in all respect as per the directions of the Engineer-in-Incharge

50

-

-

... More
Return Air Diffuser Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without aluminium volume control dampers and with anti smudge ring and removable core. Complete in all respect as per the directions of the Engineer-in-Incharge

50

-

-

... More
Fire Dampers Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Complete in all respect as per the directions of the Engineer-in-Incharge a) Fire damper

5

-

-

... More
Fire Dampers Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Complete in all respect as per the directions of the Engineer-in-Incharge b) Actuator Make: Airflow/Flaktwoods/System Air Make for Actuator: Belimo/Siemens/Honeywell

9

-

-

... More
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 and VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty.

1

-

-

... More
Supplying, installation, testing and commissioning of repeater panel wih 320 character/ LCD display with inbuilt reset, acknowledge and silence switches complete as required

1

-

-

... More
Supply, installation, testing and commissioning of the EN-54-5 / UL compliant addressable Optical Smoke detector inbuilt isolator with mounting based LED, Address card / electronic way of addressing, including required junction box, complete as per all necessary requirements. ( Detector for Above and Below Flase Celling).

972

-

-

... More
Box Type AL. Damper For Above Grilles Supplying, fixing, testing and commissioning of aluminium volume control dampers as per specifications. Complete in all respect as per the directions of the Engineer-in-Incharge Make: Airflow/System Air/Caryaire

40

-

-

... More
Supply, installation, testing and commissioning of the EN-54-5 / UL compliant addressable Optical Heat detector inbuilt isolator with mounting based LED, Address card / electronic way of addressing, including required junction box, complete as per all necessary requirements.

26

-

-

... More
Supply, installation, testing and commissioning of the EN-54-5 / UL Addressable Manual Call Points with isolator complete as required as per specifications.

23

-

-

... More
Supply, installation, testing and commissioning of the EN-54-5 / UL Fire Alarm Hooter suitable for recessed/surface mounted including addressing module complete in all respect as required.

23

-

-

... More
Supply, installation, testing and commissioning of the EN-54-5 / UL Addressable Control Module/ Relay Module/Moniter modules complete as required as per specifications.

23

-

-

... More
Supply, installation, testing and commissioning of the Response indicator. Make Pixco, Detnov, Bosch.

486

-

-

... More
Supply, installation, testing and commissioning of Fire-man Telephone console which has, 8 zone facility, location with alarm indication, phone jack and hand set. Shall we monitor for open short circuit failure, master to remote and remote master calling facility. operating voltage 220 V AC 50 Hz with inbuilt charger facility.

1

-

-

... More
Return/Exhaust Air Grille Supplying and fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. Complete in all respect as per the directions of the Engineer-in-Incharge Make: Airflow/Servex/System Air

25

-

-

... More
Supply, installation, testing and commissioning of the Fire fighter`s Telephone Jack suitable for recessed/surface mounted including addressing module complete in all respect as required.

6

-

-

... More
Supply, installing, testing and commissioning of 2 way communication Fire Fighter`s Handset.

2

-

-

... More
Supply, installation, testing and commissioning with proper connection and temination of Voice Alarm Controller having features like announcement to 10-15 zones, built in required booster amplifier, emergency microphone on the front panel, 16 priority levels including emergency, music to selected zones can be played, upto 255 messages can be stored in the internal 16MB flash ROM, individual BGM volume control for each zone, Digital pre-recorded messages can be merged, full system supervision.

1

-

-

... More
Supply, installation, testing and commissioning with proper connection and temination of booster Amplifier capable of delivering 1000 Wattage RMS power output for all speakers mentioned in BOQ, built-in fan for temperature control, built in line matching transformer distortion typically ( 3% @1 KHz, S/N) 80 dB complete as required.

1

-

-

... More
Supply, installation, testing and commissioning with proper connection and temination of Voice Alarm Call Station having gooseneck condenser microphone with zone Selection Keys and an All-Call-Key, PTT Switch, selectable gain, speech filter and limiter for improved intelligibility, LED indication for zone selection, fault and emergency state.

1

-

-

... More
Supplying, installation, testing and commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.

75

-

-

... More
Supply, Laying and Testing of 2C x 1.5 sq.mm fire survival armoured cable 600/1000 Volt rated with class-2 Copper conductor having crosslinkable low smoke zero halogen insulation as per BS EN 50363 and low smoke zero halogen (LSZH) inner and outer sheath. The cable should meet fire performance circuit integrity test as per BS EN 50200 and BS 6387 CWZ (950 Deg. C for 3 hours). The cable should be LPCB certified to EN 61034-2, EN 60754-1, BS EN 50200 and BS 6387 CWZ. Outer sheath should be in red colour with Anti-rodent and LSZH properties including end terminators, saddles, clamps with screws etc for fixing on wall/ceiling or on cable trays complete as required. ( for Detector, Devices and Telephone jack)

3800

-

-

... More
Flexible Duct Supply, Installation, Testing and Commissioning of pre-insulated factory fabricated semi-rigid flexible ducts of aluminium construction duly supported at regular interval as per site requirement Ducts shall be of following sizes: Complete in all respect as per the directions of the Engineer-in-Incharge 100 mm dia.

100

-

-

... More
Supply, Laying and Testing of FRLS type 2C X 1.5sq.mm twisted with shielded pvc insulated armoured copper wired cable, with necessary supports in existing Conduits. (For Speakers)

1500

-

-

... More
Flexible Duct Supply, Installation, Testing and Commissioning of pre-insulated factory fabricated semi-rigid flexible ducts of aluminium construction duly supported at regular interval as per site requirement Ducts shall be of following sizes: Complete in all respect as per the directions of the Engineer-in-Incharge 450 mm dia.Flexible Duct

30

-

-

... More
Flexible Duct Supply, Installation, Testing and Commissioning of pre-insulated factory fabricated semi-rigid flexible ducts of aluminium construction duly supported at regular interval as per site requirement Ducts shall be of following sizes: Complete in all respect as per the directions of the Engineer-in-Incharge 500 mm dia. Make:UP Twiga/Atco

30

-

-

... More
Fresh/Exhaust Louvers Supply, installation, testing and balancing of Powder coated/Anodised extruded aluminium construction fresh/exhaust air grille with bird screen and volume damper for fresh air as per specifications and approved shop drawings Complete in all respect as per the directions of the Engineer-in-Incharge Make: Airflow/System Air/Caryaire

20

-

-

... More
Supplying, Installing, Testing and Commissioning of following Alluminium powered coated strip line slot Diffuser.for supply air with adjustable damper Complete in all respect as per the directions of the Engineer-in-Incharge 5 slot

75

-

-

... More
Supplying, Installing, Testing and Commissioning of following Alluminium powered coated strip line slot Diffuser.for supply air with adjustable damper Complete in all respect as per the directions of the Engineer-in-Incharge 6 slot

95

-

-

... More
Volume Control Dampers Supply, installation,testing and commissioning of volume control dampers made out of 1.6mm aluminium sheet of minimum 400mm long.The blades of device shall be mill finish / block shade pivoted on nylon brushes to avoid rusting and rating noise The damper shall be opposed blade type and duly painted complete as per specification and required. Make: Airflow/System Air/Caryaire

20

-

-

... More
Supply, installation, testing and commissioning of IP fix lens 4MP Dome Camera resolution (2560×1440), H.265 True day / night Up to 30m IR distance,3D DNR, HLC and BLC, WDR,Triple streams Smart codec by ROI, It supportsH.265/H.264 video compression, multi-level video streaming configuration, support Basic/Main/ High Profile H.265 encoding complexity.PoE power supply,Basic intelligent video analytics IP 67 and IK10, UL Listed, PoE /12V DC onvif supported.

18

-

-

... More
Supply, installation, testing and commissioning of 4 megapixels resolution Network Bullet camera camera,Imager 1/2.8”SONY 2.43 mega low illumination CMOS,Video Compression. .H.264/MJPEG,Day/Night .Mechanical ICR,Minimum Illumination-0Lux/F1.4(IR ON) IR Illumination-30 M,,Electronic Shutter-Auto/Manual(1/25~1/10000) Lens 2.8 – 12 mm varifocal lens,Resolution Main-stream:D1/Q1080P(960*540)/HD720P/ HD1080P 1-25/30fps,Digital Noise Reduction-3D,Wide Dynamic Range-Digital WDR Motion Detection -4 Zones, Multi- Level Sensitivity,Privacy Zones-4 Zones,Snapshoot-Support JPEG format,Password Protection-Support,Character Display-Support(Channel /Date).Regulatory Emissions-FCC Part 15 CE: EN55022,Immunity -CE: EN50130-4,IP Rating- IP66 rated enclosure to protect against dust and water damage ONVIF compliant.

69

-

-

... More
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge 250 mm dia.(32 mm thick insulation)

50

-

-

... More
Supply, installation, testing and commissioning of 64-ch NVR with 8 SATA interface,Video Output Resolution Up to 3840 x 2160 (4K2K) , Dual Network interface,Up to 8 Megapixels resolution recording , Incoming/ outgoing Bandwidth 360 mbps, Decoding: H.265, H.264 ,Third-party IP cameras supported with ONVIF conformance: Profile S, Profile G, Profile T, Video Output HDMI x 2 / VGA x 1 / Composite x 1, up to 10TB for each HDD and USB Ports USB 3.0 x 1 / USB 2.0 x 2 , Security Multiple user access levels with password, NVR should be N plus 1, Operating Temperature 10? ~ 40? (50?~104?) , Operating Humidity 10% ~ 85%. (NVR should have 20% free space)

1

-

-

... More
Supply, installation, testing and commissioning of 32-ch NVR with 8 SATA interface, Video Output Resolution Up to 3840 x 2160 (4K2K) , Dual Network interface, Up to 8 Megapixels resolution recording, Incoming/ outgoing Bandwidth 360 mbps, Decoding: H.265, H.264 ,Third-party IP cameras supported with ONVIF conformance: Profile S, Profile G, Profile T, Video Output HDMI x 2 / VGA x 1 / Composite x 1, up to 10TB for each HDD and USB Ports USB 3.0 x 1 / USB 2.0 x 2 , Security Multiple user access levels with password, NVR should be N plus 1, Operating Temperature 10C~ 40C, Operating Humidity 10%~ 85%. (NVR should have 20% free space)

1

-

-

... More
Supply,Installation, Testing and Commisioning of 8Tb CCTV HDD storage for recording.

9

-

-

... More
Supply, installation, testing and commissioning of 24 Port PoE plus Layer -2 Gigabit Ethernet 1RU chassis. 24 100/1000 POE plus , 2 SFP/RJ45 combo, 2 SFP plus 10G ports. (Switch should have 20% free space)along with 3 years partner support.

7

-

-

... More
Supplying Installation testing and Commissioning of Layer 3, 28 - 100/1000 Base-X SFP ports, four fixed SFP plus (1G/10G) ports 1RU chassis. layer 3 from day1 having static and RIP ,stackable 8 switches, should support external redundant power supply, certified , each switch should be provided with stacking port/cable complete in all respect . ( Core Switch for Data and CCTV )along with 3 years partner support.

1

-

-

... More
Supply, installation, testing and commissioning of 1G SFP LC type.

14

-

-

... More
Supply, installation, testing and commissioning of 1G SFP to copper module. For Core to NVR Connectivity.

6

-

-

... More
Supplying, Installation, Testing and Commissioning of 43 ` LED Full HD TV Resolution 1920 x 1080, Contrast Ratio (Typical) 5000:1, Built-in Speaker (10W plus 10W), Magic Clone (to USB) Mounting Brackets as per Technical Specification complete in all respect.

2

-

-

... More
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge 200 mm dia.(32 mm thick insulation)

70

-

-

... More
Supply, Installation, Testing and Commissioning of Patch cord Should be 4 Pairs 24 AWG copper cables. The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid) UL listed (UL certificate to be provided along with the Bid) Should Have cross separator standard length should be available 0.25M/0.50M/1M. should be RoHS compliant. ( Rack end and Camera End side)

87

-

-

... More
Supplying and Fixing of 12 Port Fully loaded Single Mode, Rack-mountable, SC/LC type LIU, Enclosure should be CRS (cold rolled steel).Should be fully Secured with Lockable and Secured Steel doors and Comes multiple entry points.Enclosure should be finish black powder Coat.Enclosure should be accepts SC Duplex and Quad LC Adapters.Should be loaded with SC/LC type adopter plate.Pigtail should be 100% Factory polished, tested and guaranteed performance.Should be complete with splicing tray and other standard accessories.Should be of ROHS Compliant.

4

-

-

... More
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge 150 mm dia.(32 mm thick insulation)

100

-

-

... More
Supplying and Fixing of 24 Port Fully loaded Single Mode, Rack-mountable, SC/LC type LIU, Enclosure should be CRS (cold rolled steel).Should be fully Secured with Lockable and Secured Steel doors and Comes multiple entry points.Enclosure should be finish black powder Coat.Enclosure should be accepts SC Duplex and Quad LC Adapters.Should be loaded with SC/LC type adopter plate.Pigtail should be 100% Factory polished, tested and guaranteed performance.Should be complete with splicing tray and other standard accessories.Should be of ROHS Compliant.

1

-

-

... More
Supply, Installation, Testing and Commissioning of LC-LC Multimode 50/125-micron Duplex, LSZH Sheath, OM3 Patch Cord, 3 Meter

14

-

-

... More
Supplying, Installation, Testing and Commissioning of Cable should be of Single mode type.Cable should be of 6 core 9/125um or equivalent.Fiber cable should be of type outdoor plant type.Fiber cable should be Flame and weather retardant.Outer armoring should be of Corrugated Steel type.Outer sheath should be of HDPE type.Cable should be of ROHS compliant. ( 2core for CCTV, 2 cord for Data, 2 core for standby)

200

-

-

... More
Supplying and Fixing of Floor Standing Network/Server Rack - 42U / 800w / 1000d, with Heavy Duty Extruded Aluminium Frame for rigidity. Top cover with FHU provision. Top and Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capicity of 500Kgs. Side Panels - 42U/1000d Front MS Door Perforated honeycomb 42U/800w Rear MS Door Split Perforated honeycomb 42U/800wFan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Vertical Cable manager 80mmW 42U Shelf, Stationery 700mm N/W PDU 12Sockets 5/15Amps with MCB Mounting Hardware (Pkt. Of 20) earthing Kit 150mmH Cable manager 7 nos -1U PVC horizontal full front cover with complete in all respect.

1

-

-

... More
Supplying and Fixing of Wall mounted Network Rack - 15U /500d, with Heavy Duty Extruded. PDU 5/15Amps with MCB, Mounting Hardware (Pkt. Of 1) Cable manager 1U with Loops complete in all respect.

4

-

-

... More
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge 125 mm dia.(32 mm thick insulation)

120

-

-

... More
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge 100 mm dia.(32 mm thick insulation)

105

-

-

... More
Supply, Installation, Testing and Commissioning of Patch cord Should be 4 Pairs 24 AWG copper cables. The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid) UL listed (UL certificate to be provided along with the Bid) Should Have cross separator standard length should be available 0.25M/0.50M/1M. should be RoHS compliant. ( Rack end for DATA and EPBAX)

54

-

-

... More
Supply, Installation, Testing and Commissioning of Patch cord Should be 4 Pairs 24 AWG copper cables. The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid) UL listed (UL certificate to be provided along with the Bid) Should Have cross separator standard length should be available 2M. should be RoHS compliant. ( User End side)

54

-

-

... More
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge 80 mm dia.(32 mm thick insulation)

120

-

-

... More
Supply, Installation, Testing and Commissioning of Loaded Jack Panel should be made of cold rolled steel, should conform to TIA / EIA 568-C.2 Component Compliant, should terminate 24 UTP CAT 6 (4 pair) Cables Should confirm to EIA/TIA 568A wiring Pattern. Each port Should be features the spring-loaded shutter, should be prevents incomplete mating, should be protects from dust and contaminants, should be Front and rear port labelling as well as panel identification label, should be Integral cable management shelf ensures bend radius compliance, Operating Life should be minimum 750 insertion cycles, should be RoHS compliant.

8

-

-

... More
EPBAX Riser Cable 10 Pair

120

-

-

... More
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge 65 mm dia.(32 mm thick insulation)

110

-

-

... More
`Supply Installation, Testing and Commissioning of TEC approved as IP Enabled PBX- Voice Server expandable upto 300 extensions and configured, Personal Assistant, UCaaS Hybrid Cloud Solution for Business Collaboration and Communications, Pimphony Basic 100 license CTI Integration, Voice mail 1 Hr/2ports default, Distribution list and online recording feature license, 6 party meet me conference license, Automatic Route Selection (ARS), Hot desking 2 user license, 16 inbuilt Voice compression DSP resource, IP ready from day1, SIP Openess, Inbuilt PMS/HMS Link. Presently Configuration as Below . CO Line Nos. PRI 1Nos. Digital Extensionss 6Nos Analogue Extensions 50Nos. `

1

-

-

... More
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge 50 mm dia.(32 mm thick insulation)

265

-

-

... More
Supply Installation, Testing and Commissioning of Operator Phone : INT Premium Deskphone Moon Grey, 4 grey level display, white backlight, Handsfree, Comfort handset, Magnetic alphabetic keyboard, Jack 3,5 mm 4 pole

1

-

-

... More
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge 40 mm dia.(32 mm thick insulation)

185

-

-

... More
Supply Installation Testing and Commissioning of Digital Phone : INT Premium Deskphone Moon Grey, Black White display, white backlight, 4 programmable keys with Led Paper Label, Handsfree, Comfort handset, Magnetic alphabetic keyboard, Jack 3,5 mm 4 poles.

4

-

-

... More
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge 32 mm dia.(19 mm thick insulation)

450

-

-

... More
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge 25 mm dia.(19 mm thick insulation) Make for Pipe: TATA/JINDAL HISAR Make for Insulation: Armaflex/K -Flex/A-Flex

30

-

-

... More
Protective Coating Over The Exposed Chilled Water Piping Insulation Supplying, laying/ fixing, testing and commissioning of all insulated chilled water pipe insulation shall be coated with STARBOND 30-36/MAGIK 30-36, UL Classified Anti-Fungal insulation protective coating in conjunction with 7mil non-combustible certified Parafab GFC woven fiber glass cloth, tested as per ASTM D 4804, ASTM E 84, ASTM D-5035-11, ASTM D 1777-64 and ASTM D 3776-09, finally finished with 2 layers of Insulation protective coating to provide complete seal against air and moisture/resistance against mechanical impact, scratch, weather resistance with the properties of mold, fungus and bacterial resistance. The coating shall be complied with UL 723 i.e. Surface flame spread should be 0 and smoke developed should be also 0, coating should also comply with NFPA 90A andamp: 90B- 25/50 for parameter and the VOC level of the coating should comply with LEED IEQ 4.2 i.e. VOC level should be below than 50 gram/litter and it should also comply the guidelines of MIA 3316C- Class 1 andamp: Grade A. Complete in all respect as per the directions of the Engineer-in-Incharge FIBER GLASS CLOTH

280

-

-

... More
Protective Coating Over The Exposed Chilled Water Piping Insulation Supplying, laying/ fixing, testing and commissioning of all insulated chilled water pipe insulation shall be coated with STARBOND 30-36/MAGIK 30-36, UL Classified Anti-Fungal insulation protective coating in conjunction with 7mil non-combustible certified Parafab GFC woven fiber glass cloth, tested as per ASTM D 4804, ASTM E 84, ASTM D-5035-11, ASTM D 1777-64 and ASTM D 3776-09, finally finished with 2 layers of Insulation protective coating to provide complete seal against air and moisture/resistance against mechanical impact, scratch, weather resistance with the properties of mold, fungus and bacterial resistance. The coating shall be complied with UL 723 i.e. Surface flame spread should be 0 and smoke developed should be also 0, coating should also comply with NFPA 90A andamp: 90B- 25/50 for parameter and the VOC level of the coating should comply with LEED IEQ 4.2 i.e. VOC level should be below than 50 gram/litter and it should also comply the guidelines of MIA 3316C- Class 1 andamp: Grade A. Complete in all respect as per the directions of the Engineer-in-Incharge INSULATION COATING Make: Paramount Polytreat/Xchem International/Momansa

185

-

-

... More
INSULATED VALVES `Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Complete in all respect as per the directions of the Engineer-in-Incharge` Motorised Butter Fly Valves `Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required. ` 150 mm dia. Make: Siemens/Honeywell/Danfoss/Caleffi

6

-

-

... More
Point wiring for primary light point with 2x2.5 sq.mm and earth wire of 1.5 sq. mm (green) both are of ISI marked 1.1 kv grade FRLS PVC insulated multi strand copper wires upto max length of 10 mtr in medium class PVC conduit controlled by 6A SP mcb in distribution board complete with all necessary holder/H.D.Connector as directed.

52

-

-

... More
Wiring for secondary MCB control light points with 2X1.5 sq.mm and earth wire of 1.5 sq.mm (green) FRLS PVC insulated copper conductor single core wires upto max length of 6 mtr in the surface mounted medium class PVC conduit complete with all necessary accessories etc.

71

-

-

... More
Supply and laying of following sizes of 1.1 KV XLPE insulated Aluminium conductor armoured cables complete as required and as per specifications with cost of indoor/outdoor terimantion. 4 x 10 sq.mm. Aluminium Cable

100

-

-

... More
SITC of 1000 mm RGBW Linear Wall Washer with Non-integral driver and completely made in India luminaire. The luminaire’s shall be made of Extruded aluminum housing powder coated in grey. The complete luminaire has IP66 and IK07 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI =80 (Standard White Light) and shall have SDCM=5. The luminaire shall have system wattage 24W and shall deliver 960 lumens. Beam angle of the Luminaire shall be 11° X 11°(±5%).Fixture shall operating temperature range of 0°C to 45°C. The luminaire shall have declared life of 50,000 burning hours at L70.The luminaire shall have class I insulation. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue and White (W=4000K) to produce 16.7million colours. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. Bidder shall submit the following reports along with technical bid LM79 report. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed on each an every light fixtures. Dimension: 1000 X 35 X 39mm (±5mm) excluding bracket, Weight: 1.1Kg Approved Make: Wipro LF01-241-11-CCWG2 or equivalent in We-ef/Zumtobel`

205

-

-

... More
`SITC of Ø196 mm dia RGBW Circular Flood light with Non-integral driver and completely made in India luminaire. The luminaire’s shall be made of Aluminum die cast housing duly Powder coated. The complete luminaire has IP66 and IK08 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI =80 (Standard White Light) and shall have SDCM=5. The luminaire shall have system wattage 48W and shall deliver 2640 lumens. Beam angle of the Luminaire shall be 11deg .Fixture shall operating temperature range of 0°C to 45°C. The luminaire shall have declared life of 50,000 burning hours at L70. The luminaire shall have class I insulation. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue and White (W=4000K) to produce 16.7million colours. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. Bidder shall submit the following reports along with technical bid LM79 report. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed on each an every light fixtures. Dimension: Ø196 X 104.3mm(±5mm) excluding bracket and weight: 3Kg Approved Make: LF04-481-11-CCW-G2 or equivalent in iGuzzini/Zumtobel`

6

-

-

... More
SITC of Ø196 mm dia RGBW Circular Flood light with Non-integral driver and completely made in India luminaire. The luminaire’s shall be made of Aluminum die cast housing duly Powder coated. The complete luminaire has IP66 and IK08 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI =80 (Standard White Light) and shall have SDCM=5. The luminaire shall have system wattage 72W and shall deliver 3960 lumens. Beam angle of the Luminaire shall be 11/30/60deg .Fixture shall operating temperature range of 0°C to 45°C. The luminaire shall have declared life of 50,000 burning hours at L70. The luminaire shall have class I insulation. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue and White (W=4000K) to produce 16.7million colours. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. Bidder shall submit the following reports along with technical bid LM79 report. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed on each an every light fixtures. Dimension: Ø196 X 87.3mm(±5mm) excluding bracket and weight: 3Kg Approved Make: LF04-841 or equivalent in iGuzzini/Zumtobel`

66

-

-

... More
SITC of RGBW rectangular Flood light with Non-integral driver and completely made in India luminaire. The luminaire’s shall be made of extruded aluminium housing duly Powder coated. The complete luminaire has IP66 and IK08 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI =80 (Standard White Light) and shall have SDCM=5. The luminaire shall have system wattage 100W and shall deliver 4500 lumens. Beam angle of the Luminaire shall be 60deg .Fixture shall operating temperature range of 0°C to 45°C. The luminaire shall have declared life of 50,000 burning hours at L70. The luminaire shall have class I insulation. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue and White (W=4000K) to produce 16.7million colours. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. Bidder shall submit the following reports along with technical bid LM79 report. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed on each an every light fixtures. Dimension: 495 X 155 X 190mm(±5mm) and weight: 5Kg Approved Make: LF27-122-60-CCW-G2 or equivalent in iGuzzini/We-ef`

16

-

-

... More
SITC of RGBW rectangular Flood light with Non-integral driver and completely made in India luminaire. The luminaire’s shall be made of extruded aluminium housing duly Powder coated. The complete luminaire has IP66 and IK08 protection and it comprises of high purity integrated poly carbonate Lens.The LEDs shall have minimum CRI =80 (Standard White Light) and shall have SDCM=5. The luminaire shall have system wattage 144W and shall deliver 6480 lumens. Beam angle of the Luminaire shall be 60deg .Fixture shall operating temperature range of 0°C to 45°C. The luminaire shall have declared life of 50,000 burning hours at L70. The luminaire shall have class I insulation. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue and White (W=4000K) to produce 16.7million colours. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. Bidder shall submit the following reports along with technical bid LM79 report. LM80 , RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire. Brand name shall be embossed on each an every light fixtures. Dimension: 495 X 200 X 190mm(±5mm) and weight: 9.5Kg Approved Make: LF27-142-11-CCW-G2 or equivalent in iGuzzini/We-ef`

4

-

-

... More
SITC of 16mmX16mm of 5 meters length Warm Neon Flexible strip led light with integral/Non- Integral driver and completely potted housing with completely made in India luminaire. The luminaire’s shall be made of Silicon extrusion with high-efficiency, high grade appearance, soft bend flexibility and Option of Top bend or side bendable the same shall be so designed. The luminaire shall have silicon glue between optical cover and LED chamber to ensure proper IP67 protection, Beam angle: 110-120deg. The luminaire shall be equipped with high-power Cree/Osram/lumiled. The LEDs shall have minimum CRI =80 (White Light) and shall have SDCM=5. The luminaire shall have system wattage of 18meter/watt and shall deliver 450 lumens per meter. Fixture shall operating temperature range of 0°C to 45°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 6-bit control of RED, Green, Blue and White (W=4000K) to produce 16.7million colours. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with technical bid. Bidder shall submit the following reports along with technical bid LM79 report of the family of luminaire issued by NABL accredited lab, LM80 issued by LED manufacturer,RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire.The luminaire sample shall be tested by the Govt approved CPRI lab. Approved Make: LS27-18-TB16-CCWG1 or equivalent in Zumtobel/We-ef`

101

-

-

... More
`SITC of IP66 Extruded Aluminium body power SITC 24V output. Poweroutpur- 120W (±10%)driver featuring the constant power mode. Power SITC should operate from140~300VAC and offers models with different rated current ranging between (1.5A at full load. High efficiency up to 80%, with the fanless design, must be able to operate at -0°C ~ plus 45°C case temperature under free air convection. Output Parameters: i. Line Regulation: ±5% ii. Load regulation: ±5% iii. Output current tolerance: ±5% iv. Output voltage ripple: (3% Driver Protection: i. Input voltage protection: Cut-off Voltage : )300Vac ± 15V , Cut-in Voltage : 290Vac ± 15V ii. Output short circuit protection: Auto recovery - Hiccup mode iii. Output open circuit: Available iv. Ouput overload: Auto recovery - Hiccup mode v. Over temperature: Shutdown and Auto recovery vi. Isolation b/w input and output: Withstand 1.5KV for 1Minute vii. Insulation resistance : Between L and N to DC output:)10MO (To be measured with test voltage of 500VDC) viii. Surge in DM: 5KV Driver should have EN 61000-4-5 approval for surge voltage protection and IS 15885-2-13 for BIS approval. Dimension: 190 x 76 x 46 mm Approved Make: Wipro LG34-120-24-5AIP66 or any equivalents in Meanwell/Osram`

75

-

-

... More
`SITC of IP66 Extruded Aluminium body power SITC 24V output. Poweroutpur- 150W (±10%)driver featuring the constant power mode. Power SITC should operate from140~300VAC and offers models with different rated current ranging between (1.9A at full load. High efficiency up to 80%, with the fanless design, must be able to operate at -0°C ~ plus 45°C case temperature under free air convection. Output Parameters: i. Line Regulation: ±5% ii. Load regulation: ±5% iii. Output current tolerance: ±5% iv. Output voltage ripple: (3% Driver Protection: i. Input voltage protection: Cut-off Voltage : )300Vac ± 15V , Cut-in Voltage : 290Vac ± 15V ii. Output short circuit protection: Auto recovery - Hiccup mode iii. Output open circuit: Available iv. Ouput overload: Auto recovery - Hiccup mode v. Over temperature: Shutdown and Auto recovery vi. Isolation b/w input and output: Withstand 1.5KV for 1Minute vii. Insulation resistance : Between L and N to DC output:)10MO (To be measured with test voltage of 500VDC) viii. Surge in DM: 5KV Driver should have EN 61000-4-5 approval for surge voltage protection and IS 15885-2-13 for BIS approval. Dimension: 190 x 76 x 46 mm Approved Make: Wipro LG34-150-24-6AIP66 or any equivalents in Meanwell/Osram`

10

-

-

... More
`SITC of IP66 Extruded Aluminium body power SITC 24V output. Poweroutpur- 240W (±10%)driver featuring the constant power mode. Power SITC should operate from140~300VAC and offers models with different rated current ranging between (3.1A at full load. High efficiency up to 80%, with the fanless design, must be able to operate at -0°C ~ plus 45°C case temperature under free air convection. Output Parameters: i. Line Regulation: ±5% ii. Load regulation: ±5% iii. Output current tolerance: ±5% iv. Output voltage ripple: (3% Driver Protection: i. Input voltage protection: Cut-off Voltage : )300Vac ± 15V , Cut-in Voltage : 290Vac ± 15V ii. Output short circuit protection: Auto recovery - Hiccup mode iii. Output open circuit: Available iv. Ouput overload: Auto recovery - Hiccup mode v. Over temperature: Shutdown and Auto recovery vi. Isolation b/w input and output: Withstand 1.5KV for 1Minute vii. Insulation resistance : Between L and N to DC output:)10MO (To be measured with test voltage of 500VDC) viii. Surge in DM: 5KV Driver should have EN 61000-4-5 approval for surge voltage protection and IS 15885-2-13 for BIS approval. Dimension: 220 x 89 x 55 mm Approved Make: Wipro LG34-240-24-10IP66 or any equivalents in Meanwell/Osram`

85

-

-

... More
SITC of 5Core 5C DMX cable/Patch cord Patch Endcap 1m

341

-

-

... More
SITC of 5Core T Type 5C DMX cable

244

-

-

... More
SITC of 6 push button keypad/panel made of aluminium brushed CNC style modular with 6 individual push buttons that can trigger the Dry Port contacts.A completely made in India product. Approved Make: Wipro WL-BUTTON 6 or equivalent in iGuzzini/Zumtobel`

2

-

-

... More
SITC of DMX Master Controller, with completely made in India product. A stand alone interface for installation in electrical DIN Cabinets with Din rails, which can control from 512 to 1024 and can go up to 2048 channels on 1, 2 or 4 DMX universes. A robust Stand Alone mode and a wide range of trigger possibilities (RS232, Contacts, Clock, NODE x4 ports, Master/slave), USB-C Networks Ethernet, Internet, WIFI compatible when connected to a router Multiple Zone 10 Zone, play 10 scene/sequence per time in Stand Alone ,Memory of Micro SD Card ( max. 256 GB ) and 8Mb Internal memory . Art-Net and sACN from SD card, including triggers (2x512). A master / Save Synchro (32 max wired / 128 max Ethernet) that Commands from the Contacts (speed, scene, dimmer, zone). Default start scene, Scene priority, Cross Fade time between scenes , Automatic Scene Recovery if the power is cut off and 16-bit and fine channel management. Triggers options of RS232 In/Out (16 characters max for RS232 triggers, commands or orders) and UDP / Ethernet triggers and commands (from SDK). Software Requirements with System Compatibility of Windows, Mac, iOS. Flexible, adaptable mounting options ,Should be provided with light show authoring software, Direct line voltage power supports 100—240VAC,Minimum five configurable effects, Using light show authoring software to select from standard five effects, adjust effect settings such as color, speed, and brightness. Addressing and Programming inclusive and with Five Year Warranty. Brand name shall be embossed on each and every lighting fixtures. Approved Make: Wipro WL-DIN1024 or equivalent in we-ef/Zumtobel`

2

-

-

... More
SITC of DMX Decoder completely made in India product .Input Power DC 12V -24V input which Outputs 6A/Channels. 100-240V, 24VDC plug-in power adaptor .The number of devices controlled from 001-512 via DIP Switch. Connection of DMX (3 pin, 3.5mm pitch screw terminal). Channel bondin capable up to 10A. 8 pin terminal connector current LED connection. Compact PCB or chassis mounted.All six output ports should have an independent output driver and ELV transformer to boost the DMX signal. 1: 6 Way DMX Splitter/Booster ,Optically isolated DMX Input/Outputs, Individual coil transformer for each output , Surface/Rack/Floor/Celling mountable with provide mounting accessories ,Refined and filtered data , Cable 3 core 0.75sq.mm .Five Year Warrantyof DMX Signal Splitter plus Amplifier - One DMX512 signal Input to six DMX512 outputs, Designed to amplify, distribute and isolate DMX signals in short-runs and localised splitting scenarios. Protection of short circuit, Reverse Polarity, Over Temprature, Over Voltage and Over Current. Photo-electric isolation between Input and Output terminals as well as between output terminals among channels. Compensates for any intereference from external sources like AC lines, Electrical equipment operating close to DMX transmission lines.Compact DIN rail enclosure enables easy installation inside most enclosures. Approved Make: Wipro WL-DMX 604 or equivalent in Zumtobel/we-ef`

45

-

-

... More
SITC of DMX Splitter 1 in 6 out, Booster with completely made in India product .Input Power DC 12-24V input, 100-240V, 24VDC plug-in power adaptor included Power Consumption 4.5W max and of MS/ Aluminium Housing .The number of devices controlled from 32 to 6 X 32 Dimensions (Height x Width x Depth) 343 x123 x46mm. Power Consumption of 4.5 Approx and Weight of 1.5Kg .The output terminals should be optically isolated from the input and share a common ground reference. All six output ports should have an independent output driver and ELV transformer to boost the DMX signal. 1: 6 Way DMX Splitter/Booster ,Optically isolated DMX Input/Outputs, Individual coil transformer for each output , Surface/Rack/Floor/Celling mountable with provide mounting accessories ,Refined and filtered data , Cable 3 core 0.75sq.mm .Five Year Warrantyof DMX Signal Splitter plus Amplifier - One DMX512 signal Input to six DMX512 outputs, Designed to amplify, distribute and isolate DMX signals in short-runs and localised splitting scenarios. Photo-electric isolation between Input and Output terminals as well as between output terminals among channels. Compensates for any intereference from external sources like AC lines, Electrical equipment operating close to DMX transmission lines.Compact DIN rail enclosure enables easy installation inside most enclosures. Approved Make: Wipro WL-SPL26 or equivalent in iGuzzini/We-ef`

6

-

-

... More
Mounting clips for Neon LED Flexi strip Approved Make: Wipro LS27G1-CLP-TB16x16`

1000

-

-

... More
Providing, fixing and testing CPVC Pipes of an approved make complete with CPVC fittings such as tees, crosses, plugs, sockets, elbows, reducers, unions, sleeve pieces, check nuts etc. jointed with solvent cement compound including clamps/structural steel supports as required / directed at site including cutting and making good the walls, floors, RCC work etc. cutting chases and filling the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or cement mortar 1:4 (1 cement : 4 coarse sand) as required including cutting holes in RCC/ Masonry walls and floors wherever required and making good the same. (The cost of cutting holes of all sizes in RCC walls, slabs and beams wherever required including making good the same with sealents as required by the engineer-in-charge shall be included in the rate). 65 mm NB (73.00mm OD) (SCH-40 ASTM F-441)

385

-

-

... More
Providing, fixing and testing CPVC Pipes of an approved make complete with CPVC fittings such as tees, crosses, plugs, sockets, elbows, reducers, unions, sleeve pieces, check nuts etc. jointed with solvent cement compound including clamps/structural steel supports as required / directed at site including cutting and making good the walls, floors, RCC work etc. cutting chases and filling the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or cement mortar 1:4 (1 cement : 4 coarse sand) as required including cutting holes in RCC/ Masonry walls and floors wherever required and making good the same. (The cost of cutting holes of all sizes in RCC walls, slabs and beams wherever required including making good the same with sealents as required by the engineer-in-charge shall be included in the rate). 80 mm NB (88.90mm OD) (SCH-40 ASTM F-441)

70

-

-

... More
Providing, fixing and testing CPVC Pipes of an approved make complete with CPVC fittings such as tees, crosses, plugs, sockets, elbows, reducers, unions, sleeve pieces, check nuts etc. jointed with solvent cement compound including clamps/structural steel supports as required / directed at site including cutting and making good the walls, floors, RCC work etc. cutting chases and filling the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or cement mortar 1:4 (1 cement : 4 coarse sand) as required including cutting holes in RCC/ Masonry walls and floors wherever required and making good the same. (The cost of cutting holes of all sizes in RCC walls, slabs and beams wherever required including making good the same with sealents as required by the engineer-in-charge shall be included in the rate). 100 mm NB (114.30mm OD) (SCH-40 ASTM F-441)

570

-

-

... More
Supply, fixing, testing and commissioning of Air Release Valves screwed ends with ball valve of approved brand of manufacture, with accessories etc., complete.

3

-

-

... More
Providing and fixing class-O Careflex ST insulation 6mm thick to hot water pipe and fittings and valves as per manufacturer`s recommendations complete to satisfaction of Engineer in charge.16mm nominal bore (6 mm thick insulation)

15

-

-

... More
Providing and fixing class-O Careflex ST insulation 6mm thick to hot water pipe and fittings and valves as per manufacturer`s recommendations complete to satisfaction of Engineer in charge.22mm nominal bore (6 mm thick insulation)

100

-

-

... More
KOHLER make Cat. No. K-2075IN-1-0 (Under counter) Self-rimming basin with single faucet hole in white with C.P. single level basin mixer KOHLER Cat No. K-97060IN-4-CP Single control basin faucet with drain in polished chrome, C.P. brass waste KOHLER Cat. No. K-45432IN-CP (Grid drain with overflow hole in polished chrome) and C.P. bottle trap KOHLER Cat. No. K-16407IN-CP (Bottle trap - 210mm in polished chrome).

2

-

-

... More
Providing and Fixing Health Faucet With Sdspray, Metal Hose KOHLER Cat. No.- K-12927IN-CP with flexible pipe and wall hook with each European W.C. Pan.

17

-

-

... More
Providing and fixing C.P. brass Towel Ring in polished chrome KOHLER Cat. No. -K-5631IN-CP complete with C.P. brass brackets fixed to rawl plug of approved design with C.P. brass screws.

1

-

-

... More
Providing and fixing S.S. Hinged Grating, 1.5mm thick with frame JAYNA NEW HEAVY GRATINGS Cat. No. NHG 140 including setting in floor with cement mortar 1:3.

29

-

-

... More
Providing and fixing, Soap Dispenser with holder in polished chrome (KOHLER Cat No. K-10712D-CP) Make or approved equivalent.

11

-

-

... More
Providing and fixing white glazed vitreous china Division Plates for urinals (H.S.I. Cat no. 61001 approved equivalent) of size 680x 300 mm.

12

-

-

... More
Providing and fixing C.P. brass Soap dish in polished chrome (KOHLER Cat. No. -K-5634IN-CP) or approved equivalent including cutting and making good the walls wherever required complete to the satisfaction of Engineer in charge.

1

-

-

... More
Providing and fixing automatic high pressure electric water heaters (VENUS or approved equivalent) with glass lining thermostats with each element and high temperature cut off, necessary insulation, safety valve, etc. all complete.

1

-

-

... More
Providing and fixing Hand Dryer - Hand dryer in white KOHLER Cat No. K-5486T-0P fixed in position by means of C.P. screws and rawl plugs embedded in the walls complete including cutting and making good the walls wherever required.

7

-

-

... More
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. Complete in all respect as per the directions of the Engineer-in-Incharge. 150 mm dia. Make: Advance/Castle/Audco Note: 32 mm shall be of forged brass and screwed connection.

6

-

-

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required Complete in all respect as per the directions of the Engineer-in-Incharge. Make: H. Guru/Fiebig/Anergy

30

-

-

... More
Providing and fixing in position the mercury in glass industrial type thermometers. Complete in all respect as per the directions of the Engineer-in-Incharge. Make: H. Guru/Fiebig/Anergy

18

-

-

... More
Supply,installation,testing and commissioning of Autometic Air Vents . Complete in all respect as per the directions of the Engineer-in-Incharge. 15 mm

50

-

-

... More
Supply,installation,testing and commissioning of Autometic Air Vents . Complete in all respect as per the directions of the Engineer-in-Incharge. 20 mm Make: Caleffi/Spirotech/Spirotherm

25

-

-

... More
Pressure Independent Control Valve (PICV) `Pressure independent control valve (PICV) complete with quick-fit pressure/temperature ports. Size DN 15 (from DN 32 to DN 50). Main connections 1/2” M (from 1/2” to 1 1/4”) (ISO 228-1). Dezincification resistant alloy body and headwork. Control stem, piston and springs in stainless steel. Pressure regulator diaphragm, obturator and seals in EPDM. Asbestos-free fibre seals. Pre-adjustment indicator in PA6G30. Knob in PA6. Maximum working pressure 25 bar. Maximum differential pressure with actuator code 145013 (and 6565 series) installed 5 bar. Working temperature range -20–120°C. Nominal Dp control range 25–400 kPa. Accuracy ± 5 % of the setpoint. Flow rate regulation range 0,02–0,2 m3/h (0,02–0,2 m3/h, 0,08–0,4 m3/h, 0,08–0,8 m3/h, 0,12–1,2 m3/h, 0,18–1,8 m3/h, 0,3–3 m3/h and 0,37–3,7 m3/h). The adjustment position does not affect the obturator stroke. Full stroke modulation. Flow rate pre-adjustment device with at least 10 reference positions and continuous adjustment. Leakage class V according to EN60534-4. Diaphragm pressure regulator. Complete with On - Off OR Modulating actuator Complete in all respect as per the directions of the Engineer-in-Incharge. ` 80 mm dia pipe for AHUs

3

-

-

... More
Pressure Independent Control Valve (PICV) `Pressure independent control valve (PICV) complete with quick-fit pressure/temperature ports. Size DN 15 (from DN 32 to DN 50). Main connections 1/2” M (from 1/2” to 1 1/4”) (ISO 228-1). Dezincification resistant alloy body and headwork. Control stem, piston and springs in stainless steel. Pressure regulator diaphragm, obturator and seals in EPDM. Asbestos-free fibre seals. Pre-adjustment indicator in PA6G30. Knob in PA6. Maximum working pressure 25 bar. Maximum differential pressure with actuator code 145013 (and 6565 series) installed 5 bar. Working temperature range -20–120°C. Nominal Dp control range 25–400 kPa. Accuracy ± 5 % of the setpoint. Flow rate regulation range 0,02–0,2 m3/h (0,02–0,2 m3/h, 0,08–0,4 m3/h, 0,08–0,8 m3/h, 0,12–1,2 m3/h, 0,18–1,8 m3/h, 0,3–3 m3/h and 0,37–3,7 m3/h). The adjustment position does not affect the obturator stroke. Full stroke modulation. Flow rate pre-adjustment device with at least 10 reference positions and continuous adjustment. Leakage class V according to EN60534-4. Diaphragm pressure regulator. Complete with On - Off OR Modulating actuator Complete in all respect as per the directions of the Engineer-in-Incharge. ` 65 mm dia pipe for AHUs

7

-

-

... More
Pressure Independent Control Valve (PICV) `Pressure independent control valve (PICV) complete with quick-fit pressure/temperature ports. Size DN 15 (from DN 32 to DN 50). Main connections 1/2” M (from 1/2” to 1 1/4”) (ISO 228-1). Dezincification resistant alloy body and headwork. Control stem, piston and springs in stainless steel. Pressure regulator diaphragm, obturator and seals in EPDM. Asbestos-free fibre seals. Pre-adjustment indicator in PA6G30. Knob in PA6. Maximum working pressure 25 bar. Maximum differential pressure with actuator code 145013 (and 6565 series) installed 5 bar. Working temperature range -20–120°C. Nominal Dp control range 25–400 kPa. Accuracy ± 5 % of the setpoint. Flow rate regulation range 0,02–0,2 m3/h (0,02–0,2 m3/h, 0,08–0,4 m3/h, 0,08–0,8 m3/h, 0,12–1,2 m3/h, 0,18–1,8 m3/h, 0,3–3 m3/h and 0,37–3,7 m3/h). The adjustment position does not affect the obturator stroke. Full stroke modulation. Flow rate pre-adjustment device with at least 10 reference positions and continuous adjustment. Leakage class V according to EN60534-4. Diaphragm pressure regulator. Complete with On - Off OR Modulating actuator Complete in all respect as per the directions of the Engineer-in-Incharge. ` 50 mm dia pipe for AHUs

10

-

-

... More
Pressure Independent Control Valve (PICV) `Pressure independent control valve (PICV) complete with quick-fit pressure/temperature ports. Size DN 15 (from DN 32 to DN 50). Main connections 1/2” M (from 1/2” to 1 1/4”) (ISO 228-1). Dezincification resistant alloy body and headwork. Control stem, piston and springs in stainless steel. Pressure regulator diaphragm, obturator and seals in EPDM. Asbestos-free fibre seals. Pre-adjustment indicator in PA6G30. Knob in PA6. Maximum working pressure 25 bar. Maximum differential pressure with actuator code 145013 (and 6565 series) installed 5 bar. Working temperature range -20–120°C. Nominal Dp control range 25–400 kPa. Accuracy ± 5 % of the setpoint. Flow rate regulation range 0,02–0,2 m3/h (0,02–0,2 m3/h, 0,08–0,4 m3/h, 0,08–0,8 m3/h, 0,12–1,2 m3/h, 0,18–1,8 m3/h, 0,3–3 m3/h and 0,37–3,7 m3/h). The adjustment position does not affect the obturator stroke. Full stroke modulation. Flow rate pre-adjustment device with at least 10 reference positions and continuous adjustment. Leakage class V according to EN60534-4. Diaphragm pressure regulator. Complete with On - Off OR Modulating actuator Complete in all respect as per the directions of the Engineer-in-Incharge. ` 40 mm dia pipe for AHUs

7

-

-

... More
Pressure Independent Control Valve (PICV) `Pressure independent control valve (PICV) complete with quick-fit pressure/temperature ports. Size DN 15 (from DN 32 to DN 50). Main connections 1/2” M (from 1/2” to 1 1/4”) (ISO 228-1). Dezincification resistant alloy body and headwork. Control stem, piston and springs in stainless steel. Pressure regulator diaphragm, obturator and seals in EPDM. Asbestos-free fibre seals. Pre-adjustment indicator in PA6G30. Knob in PA6. Maximum working pressure 25 bar. Maximum differential pressure with actuator code 145013 (and 6565 series) installed 5 bar. Working temperature range -20–120°C. Nominal Dp control range 25–400 kPa. Accuracy ± 5 % of the setpoint. Flow rate regulation range 0,02–0,2 m3/h (0,02–0,2 m3/h, 0,08–0,4 m3/h, 0,08–0,8 m3/h, 0,12–1,2 m3/h, 0,18–1,8 m3/h, 0,3–3 m3/h and 0,37–3,7 m3/h). The adjustment position does not affect the obturator stroke. Full stroke modulation. Flow rate pre-adjustment device with at least 10 reference positions and continuous adjustment. Leakage class V according to EN60534-4. Diaphragm pressure regulator. Complete with On - Off OR Modulating actuator Complete in all respect as per the directions of the Engineer-in-Incharge. ` 32 mm dia pipe for AHUs

22

-

-

... More
Pressure Independent Control Valve (PICV) `Pressure independent control valve (PICV) complete with quick-fit pressure/temperature ports. Size DN 15 (from DN 32 to DN 50). Main connections 1/2” M (from 1/2” to 1 1/4”) (ISO 228-1). Dezincification resistant alloy body and headwork. Control stem, piston and springs in stainless steel. Pressure regulator diaphragm, obturator and seals in EPDM. Asbestos-free fibre seals. Pre-adjustment indicator in PA6G30. Knob in PA6. Maximum working pressure 25 bar. Maximum differential pressure with actuator code 145013 (and 6565 series) installed 5 bar. Working temperature range -20–120°C. Nominal Dp control range 25–400 kPa. Accuracy ± 5 % of the setpoint. Flow rate regulation range 0,02–0,2 m3/h (0,02–0,2 m3/h, 0,08–0,4 m3/h, 0,08–0,8 m3/h, 0,12–1,2 m3/h, 0,18–1,8 m3/h, 0,3–3 m3/h and 0,37–3,7 m3/h). The adjustment position does not affect the obturator stroke. Full stroke modulation. Flow rate pre-adjustment device with at least 10 reference positions and continuous adjustment. Leakage class V according to EN60534-4. Diaphragm pressure regulator. Complete with On - Off OR Modulating actuator Complete in all respect as per the directions of the Engineer-in-Incharge. ` 25 mm dia pipe for AHUs

9

-

-

... More
Pressure Independent Control Valve (PICV) `Pressure independent control valve (PICV) complete with quick-fit pressure/temperature ports. Size DN 15 (from DN 32 to DN 50). Main connections 1/2” M (from 1/2” to 1 1/4”) (ISO 228-1). Dezincification resistant alloy body and headwork. Control stem, piston and springs in stainless steel. Pressure regulator diaphragm, obturator and seals in EPDM. Asbestos-free fibre seals. Pre-adjustment indicator in PA6G30. Knob in PA6. Maximum working pressure 25 bar. Maximum differential pressure with actuator code 145013 (and 6565 series) installed 5 bar. Working temperature range -20–120°C. Nominal Dp control range 25–400 kPa. Accuracy ± 5 % of the setpoint. Flow rate regulation range 0,02–0,2 m3/h (0,02–0,2 m3/h, 0,08–0,4 m3/h, 0,08–0,8 m3/h, 0,12–1,2 m3/h, 0,18–1,8 m3/h, 0,3–3 m3/h and 0,37–3,7 m3/h). The adjustment position does not affect the obturator stroke. Full stroke modulation. Flow rate pre-adjustment device with at least 10 reference positions and continuous adjustment. Leakage class V according to EN60534-4. Diaphragm pressure regulator. Complete with On - Off OR Modulating actuator Complete in all respect as per the directions of the Engineer-in-Incharge. ` 20 mm dia pipe for AHUs Make: Caleffi/Danfoss/Belimo

1

-

-

... More
Supply,installation,testing and commissioning of Ball valves for header and equipment drain with fittings etc. Complete in all respect as per the directions of the Engineer-in-Incharge. 25 mm Make: Leader/Sant/Rapidcool

100

-

-

... More
FCU/HCU CAR KIT Supply,installation, testing and Commisioning of Connection and regulation kit for HVAC fan coil units / hydronic cassette unit in heating/ cooling systems. Complete with: pressure independent control valve with proportional linear actuator (Modulating type ), three-way shut-off valves, integrated by-pass, Venturi device with pressure test ports, shut off valve with strainer and shell insulation made of PPE. NOTE : all given parts should be of one single manufacturer,no different manufacturer assembelled unit is acceptable. Linear or equipotential flow rate adjustment characteristic, which can be set up by actuator depending on the characteristics of the terminal unit. Maximum working pressure 25 bar. Maximum differential pressure with actuator installed: 5 bar. Nominal operation ?p range 25–400 kPa. Working temperature range -10-120°C. Ambient temperature range 0-50°C. Strainer mesh size 800 µm. Dezincification resistant alloy body and adjustment headwork: stainless steel strainer mesh: EPDM diaphragm, obturator and seals. One pair of flexible connection with threaded nut / clamp to be provided between the unit and kit of suitable length. Complete in all respect as per the directions of the Engineer-in-Incharge. 20 mm dia for HCU/FCU

1

-

-

... More
FCU/HCU CAR KIT Supply,installation, testing and Commisioning of Connection and regulation kit for HVAC fan coil units / hydronic cassette unit in heating/ cooling systems. Complete with: pressure independent control valve with proportional linear actuator (Modulating type ), three-way shut-off valves, integrated by-pass, Venturi device with pressure test ports, shut off valve with strainer and shell insulation made of PPE. NOTE : all given parts should be of one single manufacturer,no different manufacturer assembelled unit is acceptable. Linear or equipotential flow rate adjustment characteristic, which can be set up by actuator depending on the characteristics of the terminal unit. Maximum working pressure 25 bar. Maximum differential pressure with actuator installed: 5 bar. Nominal operation ?p range 25–400 kPa. Working temperature range -10-120°C. Ambient temperature range 0-50°C. Strainer mesh size 800 µm. Dezincification resistant alloy body and adjustment headwork: stainless steel strainer mesh: EPDM diaphragm, obturator and seals. One pair of flexible connection with threaded nut / clamp to be provided between the unit and kit of suitable length. Complete in all respect as per the directions of the Engineer-in-Incharge. 25 mm dia for HCU/FCU

8

-

-

... More
FCU/HCU CAR KIT Supply,installation, testing and Commisioning of Connection and regulation kit for HVAC fan coil units / hydronic cassette unit in heating/ cooling systems. Complete with: pressure independent control valve with proportional linear actuator (Modulating type ), three-way shut-off valves, integrated by-pass, Venturi device with pressure test ports, shut off valve with strainer and shell insulation made of PPE. NOTE : all given parts should be of one single manufacturer,no different manufacturer assembelled unit is acceptable. Linear or equipotential flow rate adjustment characteristic, which can be set up by actuator depending on the characteristics of the terminal unit. Maximum working pressure 25 bar. Maximum differential pressure with actuator installed: 5 bar. Nominal operation ?p range 25–400 kPa. Working temperature range -10-120°C. Ambient temperature range 0-50°C. Strainer mesh size 800 µm. Dezincification resistant alloy body and adjustment headwork: stainless steel strainer mesh: EPDM diaphragm, obturator and seals. One pair of flexible connection with threaded nut / clamp to be provided between the unit and kit of suitable length. Complete in all respect as per the directions of the Engineer-in-Incharge. 32 mm dia for HCU/FCU Makes: Caleffi / Oventrop / Frease

7

-

-

... More
Expansion Tank (PVC-1000 Ltr.) Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Complete in all respect as per the directions of the Engineer-in-Incharge. Make: Sintex/J.S. Polyplast/Polycon

1000

-

-

... More
Expansion Tank Insulation(19mm thick) Supplying , installation, testing and commissioning of external thermal insulation on tank with Duly laminated aluminum foil of mat finish Closed Cell Cross Linked Polyethylene (class “O”) insulation shall be 27 ± 3 Kg/m3. The product shall have temperature range of –40 oC to 105oC. Thermal Conductive not exceeding 0.033 W/mK at an average Temperature of 23°C. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6 : 1989 for fire propagation test and for Class 0 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability shall be not less than 0.024 per inch (2.48 x 10-14 Kg/m.s.Pa i.e. µ)7000: Water vapour diffusion resistance).The Material shall have Fire Approval from CBRI - Roorkee Complete in all respect as per the directions of the Engineer-in-Incharge. CANI/Thermobreak

5

-

-

... More
PVC Drain Piping Supply, Installation, testing and commissioning of PVC piping complete with fittings, supports accessories in surface/recess as per specifications and site requirments including with duly insulated with 6 mm thick sleeve of nitrle rubber having K value 0.033 W/MK at 10 deg. C mean temp. and minimum density of 25 Kg/Cum. Insulation on drain pipe Complete in all respect as per the directions of the Engineer-in-Incharge. 25 mm Dia

160

-

-

... More
PVC Drain Piping Supply, Installation, testing and commissioning of PVC piping complete with fittings, supports accessories in surface/recess as per specifications and site requirments including with duly insulated with 6 mm thick sleeve of nitrle rubber having K value 0.033 W/MK at 10 deg. C mean temp. and minimum density of 25 Kg/Cum. Insulation on drain pipe Complete in all respect as per the directions of the Engineer-in-Incharge. 32 mm dia

160

-

-

... More
PVC Drain Piping Supply, Installation, testing and commissioning of PVC piping complete with fittings, supports accessories in surface/recess as per specifications and site requirments including with duly insulated with 6 mm thick sleeve of nitrle rubber having K value 0.033 W/MK at 10 deg. C mean temp. and minimum density of 25 Kg/Cum. Insulation on drain pipe Complete in all respect as per the directions of the Engineer-in-Incharge. 40 mm dia

100

-

-

... More
PVC Drain Piping Supply, Installation, testing and commissioning of PVC piping complete with fittings, supports accessories in surface/recess as per specifications and site requirments including with duly insulated with 6 mm thick sleeve of nitrle rubber having K value 0.033 W/MK at 10 deg. C mean temp. and minimum density of 25 Kg/Cum. Insulation on drain pipe Complete in all respect as per the directions of the Engineer-in-Incharge. 50 mm dia Makes: AKG/Supreme/Astral

90

-

-

... More
`Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS `C` class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge. ` 300 mm dia.

70

-

-

... More
CONDENSER WATER PIPE `Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS `C` class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge. ` 200 mm dia.

50

-

-

... More
CONDENSER WATER PIPE `Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS `C` class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge. ` 150 mm dia.

75

-

-

... More
CONDENSER WATER PIPE `Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS `C` class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge. ` 100 mm dia.

25

-

-

... More
CONDENSER WATER PIPE `Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS `C` class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge. ` 80 mm dia.

30

-

-

... More
CONDENSER WATER PIPE `Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS `C` class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Complete in all respect as per the directions of the Engineer-in-Incharge. ` 50 mm dia. Make: TATA/JINDAL HISAR

30

-

-

... More
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Complete in all respect as per the directions of the Engineer-in-Incharge. `Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required. Complete in all respect as per the directions of the Engineer-in-Incharge. ` 200 mm dia.

6

-

-

... More
BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet and O - ring and PN 16 pressure rating as specified.Complete in all respect as per the directions of the Engineer-in-Incharge. 200 mm dia.

6

-

-

... More
BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet and O - ring and PN 16 pressure rating as specified.Complete in all respect as per the directions of the Engineer-in-Incharge. 150 mm dia.

9

-

-

... More
BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet and O - ring and PN 16 pressure rating as specified.Complete in all respect as per the directions of the Engineer-in-Incharge. 100 mm dia.

3

-

-

... More
BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet and O - ring and PN 16 pressure rating as specified.Complete in all respect as per the directions of the Engineer-in-Incharge. 80 mm dia.

3

-

-

... More
BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet and O - ring and PN 16 pressure rating as specified.Complete in all respect as per the directions of the Engineer-in-Incharge. 50 mm dia.

3

-

-

... More
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation and PN 16 pressure rating for chilled / hot water circulation as specified. Complete in all respect as per the directions of the Engineer-in-Incharge. 200 mm dia. Make: Advance/Castle/Audco

6

-

-

... More
M.S Y-Strainer Complete with Stainless Steel Bucket having 03 mm Perforation, flanged ends. Filteration area 1:4 Complete in all respect as per the directions of the Engineer-in-Incharge. 200 mm dia. Make: Advance/Castle/Audco

1

-

-

... More
M.S POT-Strainer Complete with Stainless Steel Bucket having 03 mm Perforation, flanged ends. Filteration area 1:4. Complete in all respect as per the directions of the Engineer-in-Incharge. 200 mm dia. Make: Emerald/Sant/Maharaja

1

-

-

... More
Dirt Separator for open loop CNDW pipe `Supply installation testing and commisioning of Deaerator-dirt separator. Flanged connections, complete with Brass drain valve 1” F (from DN 50 to DN 150), 2” F (from DN 200 to DN 300). complete with a set of concentric metal mesh surfaces to create the swirling motion required to facilitate the dirt to the surfaces. Epoxy resin coated steel body. Stainless steel internal element. PP float. Brass float guide and stem. Stainless steel float lever and spring. EPDM hydraulic seals.Maximum working pressure 10 bar. Working temperature range 0–110°C. Particle separation rating down to 5 µ.Working temperature range 0–100°C. Floor brackets as per site requirement. Complete in all respect as per the directions of the Engineer-in-Incharge. ` 300 mm dia. Make: Caleffi/Spirotech/Spirotherm

1

-

-

... More
Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 plus 10% volts, 50 plus 3% Hz and of 50 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. Incoming 1 No. 1000 Amps 415 volt 50 kA TPN MDO type ACB with microprocessor release having overcurrent and short circuit protection and CBCT and ELR complete with rotary operating mechanism with spreader. Metering i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 800/5 amps 10 VA CT`s to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set Bus-bar Main bus bar rated at 1200 amps 4 pole, 50 KA with heat shrinkable sleeve and shall be of aluminium. Outgoings 3 Nos 400 amp 35 kA TP plus NL MCCB with microprocessor release having overcurrent and short circuit protection for Chiller (160 KW). 3 Nos. 63 amps TP MPCB with Star Delta starter for 22.0 KW motor , over load relay with built in single phasing protection and outgoing feeder to Conderser Water Pump. The compartment shall contain an indicating lamp with MCB for ON and OFF status of pump motor. 3 Nos. 25 amps TP MPCB with Star Delta starter for 7.5 KW motor , over load relay with built in single phasing protection and outgoing feeder to Primary Chilled Water Pump. The compartment shall contain an indicating lamp with MCB for ON and OFF status of pump motor. 3 Nos. 50 amps TPN MCCB with thermal magnetic release having overcurrent and short circuit protection with space provision of VFD for Secondary Chilled Water Pump (15.0 KW). 6 Nos. 25 amps TP MPCB with Star Delta starter for 7.5 KW motor , over load relay with built in single phasing protection and outgoing feeder to Cooling Tower Fan Motor. The compartment shall contain an indicating lamp with MCB for ON and OFF status of fan motor. 2 Nos. 4-6.3 amps TP MPCB with DOL starter for 2.2 KW motor , over load relay with built in single phasing protection and outgoing feeder to HVAC Plant Room FA/EA Fan Motor. The compartment shall contain an indicating lamp with MCB for ON and OFF status of fan motor. Potential Free Contact for BMS as required.

1

-

-

... More
Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 plus 10% volts, 50 plus 3% Hz and of 50 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. Complete in all respect as per the directions of the Engineer-in-Incharge Incoming 1 No. 160 Amps 415 volt 50 kA 4P MCCB with microprocessor release having overcurrent and short circuit protection and CBCT and ELR complete with rotary operating mechanism with spreader. Metering i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 160/5 amps 10 VA CT`s to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set Bus-bar Main bus bar rated at 200 amps 4 pole, 50 kA with heat shrinkable sleeve and shall be of aluminium. Outgoings 9 Nos. 4.0-6.3 amps TP, MPCB with DOL starter for 2.2 KW motor, with built in single phasing protection and outgoing feeder to Pressurization Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 9-13 amps TP, MPCB with DOL starter for 5.5 KW motor, with built in single phasing protection and outgoing feeder to Pressurization Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor

1

-

-

... More
Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 plus 10% volts, 50 plus 3% Hz and of 50 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. Complete in all respect as per the directions of the Engineer-in-Incharge Incoming 1 No. 250 Amps 415 volt 50 kA 4P MCCB with microprocessor release having overcurrent and short circuit protection and CBCT and ELR complete with rotary operating mechanism with spreader. Metering i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 250/5 amps 10 VA CT`s to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set Bus-bar Main bus bar rated at 400 amps 4 pole, 50 kA with heat shrinkable sleeve and shall be of aluminium. Outgoings 6 Nos. 32 amps TP, MPCB with Star Delta starter for 11 KW motor, with built in single phasing protection and outgoing feeder to emergency supply/exhaust air Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 25 amps TP, MPCB with Star Delta starter for 7.5 KW motor, with built in single phasing protection and outgoing feeder to emergency supply/exhaust air Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 9-13 amps TP, MPCB with DOL starter for 5.5 KW motor, with built in single phasing protection and outgoing feeder to emergency supply/exhaust air Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor

1

-

-

... More
Main Panel for AHUs Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 plus 10% volts, 50 plus 3% Hz and of 50 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. Complete in all respect as per the directions of the Engineer-in-Incharge Incoming 1 No. 315 Amps 415 volt 50 kA 4P MCCB with microprocessor release having overcurrent and short circuit protection and CBCT and ELR complete with rotary operating mechanism with spreader. Metering i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 315/5 amps 10 VA CT`s to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set Bus-bar Main bus bar rated at 500 amps 4 pole, 50 kA with heat shrinkable sleeve and shall be of aluminium. Outgoings 1 Nos. 80 amps 4P,MCCB for AHU PANEL-1 (Basement). The compartment shall contain an indicating lamp with MCB for ON/OFF status. 1 Nos. 63 amps 4P,MCCB for AHU PANEL-2 (Ground Floor LHS). The compartment shall contain an indicating lamp with MCB for ON/OFF status. 1 Nos. 63 amps 4P,MCCB for AHU PANEL-3 (Ground Floor RHS). The compartment shall contain an indicating lamp with MCB for ON/OFF status. 1 Nos. 125 amps 4P,MCCB for AHU PANEL-4 (First Floor LHS). The compartment shall contain an indicating lamp with MCB for ON/OFF status. 1 Nos. 63 amps 4P,MCCB for AHU PANEL-5 (First Floor RHS). The compartment shall contain an indicating lamp with MCB for ON/OFF status. 1 Nos. 80 amps 4P,MCCB for AHU PANEL-6 (Second Floor). The compartment shall contain an indicating lamp with MCB for ON/OFF status.

1

-

-

... More
Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 plus 10% volts, 50 plus 3% Hz and of 50 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. Complete in all respect as per the directions of the Engineer-in-Incharge Incoming 1 No. 80 Amps 415 volt 50 kA 4P MCCB with microprocessor release having overcurrent and short circuit protection and CBCT and ELR complete with rotary operating mechanism with spreader. Metering i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 125/5 amps 10 VA CT`s to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set Bus-bar Main bus bar rated at 150 amps 4 pole, 50 kA with heat shrinkable sleeve and shall be of aluminium. Outgoings 7 Nos. 6.3-10 amps TP, MPCB with DOL starter for 3.7 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 1 No. 6 amps 2 Pole MCB for room thermostat/EV AHU KIT.

1

-

-

... More
Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 plus 10% volts, 50 plus 3% Hz and of 50 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. Complete in all respect as per the directions of the Engineer-in-Incharge Incoming 1 No. 63 Amps 415 volt 50 kA 4P MCCB with microprocessor release having overcurrent and short circuit protection and CBCT and ELR complete with rotary operating mechanism with spreader. Metering i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 25/5 amps 10 VA CT`s to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set Bus-bar Main bus bar rated at 100 amps 4 pole, 50 kA with heat shrinkable sleeve and shall be of aluminium. Outgoings 2 Nos. 2.5-4 amps TP, MPCB with DOL starter for 3.7 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 3 Nos. 4-6.3 amps TP, MPCB with DOL starter for 1.1 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 6 amps 2 Pole MCB for fire damper actuator. 1 No. 6 amps 2 Pole MCB for room thermostat/EV AHU KIT.

2

-

-

... More
Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 plus 10% volts, 50 plus 3% Hz and of 50 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. Complete in all respect as per the directions of the Engineer-in-Incharge Incoming 1 No. 63 Amps 415 volt 50 kA 4P MCCB with microprocessor release having overcurrent and short circuit protection and CBCT and ELR complete with rotary operating mechanism with spreader. Metering i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 25/5 amps 10 VA CT`s to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set Bus-bar Main bus bar rated at 100 amps 4 pole, 50 kA with heat shrinkable sleeve and shall be of aluminium. Outgoings 1 Nos. 6.3-10 amps TP, MPCB with DOL starter for 3.7 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 4 Nos. 4-6.3 amps TP, MPCB with DOL starter for 2.2 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 4-6.3 amps TP, MPCB with DOL starter for 1.1 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 6 amps 2 Pole MCB for fire damper actuator. 1 No. 6 amps 2 Pole MCB for room thermostat/EV AHU KIT.

1

-

-

... More
Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 plus 10% volts, 50 plus 3% Hz and of 50 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. Complete in all respect as per the directions of the Engineer-in-Incharge Incoming 1 No. 125 Amps 415 volt 50 kA 4P MCCB with microprocessor release having overcurrent and short circuit protection and CBCT and ELR complete with rotary operating mechanism with spreader. Metering i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 100/5 amps 10 VA CT`s to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set Bus-bar Main bus bar rated at 200 amps 4 pole, 50 kA with heat shrinkable sleeve and shall be of aluminium. Outgoings 1 Nos. 25 amps TP, MPCB with Star Delta starter for 9.3 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 1 Nos. 25 amps TP, MPCB with Star Delta starter for 7.5 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 3 Nos. 6.3-10 amps TP, MPCB with DOL starter for 3.7 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 3 Nos. 4-6.3 amps TP, MPCB with DOL starter for 2.2 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 2.5-4 amps TP, MPCB with DOL starter for 1.1 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 6 amps 2 Pole MCB for fire damper actuator. 1 No. 6 amps 2 Pole MCB for room thermostat/EV AHU KIT.

1

-

-

... More
Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 plus 10% volts, 50 plus 3% Hz and of 50 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. Complete in all respect as per the directions of the Engineer-in-Incharge Incoming 1 No. 63 Amps 415 volt 50 kA 4P MCCB with microprocessor release having overcurrent and short circuit protection and CBCT and ELR complete with rotary operating mechanism with spreader. Metering i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 100/5 amps 10 VA CT`s to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set Bus-bar Main bus bar rated at 100 amps 4 pole, 50 kA with heat shrinkable sleeve and shall be of aluminium. Outgoings 1 Nos. 6.3-10 amps TP, MPCB with DOL starter for 3.7 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 4-6.3 amps TP, MPCB with DOL starter for 2.2 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 1 Nos. 6.3-10 amps TP, MPCB with DOL starter for 1.5 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 6.3-10 amps TP, MPCB with DOL starter for 1.1 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 6 amps 2 Pole MCB for fire damper actuator. 1 No. 6 amps 2 Pole MCB for room thermostat/EV AHU KIT.

1

-

-

... More
Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 plus 10% volts, 50 plus 3% Hz and of 50 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. Complete in all respect as per the directions of the Engineer-in-Incharge Incoming 1 No. 80 Amps 415 volt 50 kA 4P MCCB with microprocessor release having overcurrent and short circuit protection and CBCT and ELR complete with rotary operating mechanism with spreader. Metering i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 63/5 amps 10 VA CT`s to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set Bus-bar Main bus bar rated at 150 amps 4 pole, 50 kA with heat shrinkable sleeve and shall be of aluminium. Outgoings 2 Nos. 6.3-10 amps TP, MPCB with DOL starter for 3.7 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 5 Nos. 6.3-10 amps TP, MPCB with DOL starter for 2.2 KW motor, with built in single phasing protection and outgoing feeder to AHU/TFA Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 4-6.3 amps TP, MPCB with DOL starter for 1.1 KW motor, with built in single phasing protection and outgoing feeder to AHU Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 6 amps 2 Pole MCB for fire damper actuator. 1 No. 6 amps 2 Pole MCB for room thermostat/EV AHU KIT.

1

-

-

... More
EMERGENCY VENTILATION FAN PANEL-3 Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 plus 10% volts, 50 plus 3% Hz and of 50 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required.Complete in all respect as per the directions of the Engineer-in-Incharge Incoming 1 No. 63 Amps 415 volt 50 kA 4P MCCB with microprocessor release having overcurrent and short circuit protection and CBCT and ELR complete with rotary operating mechanism with spreader. Metering i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 63/5 amps 10 VA CT`s to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set Bus-bar Main bus bar rated at 100 amps 4 pole, 50 kA with heat shrinkable sleeve and shall be of aluminium. Outgoings 4 Nos. 4.0-6.3 amps TP, MPCB with DOL starter for 3 KW motor, with built in single phasing protection and outgoing feeder to emergency supply/exhaust Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor

1

-

-

... More
Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 plus 10% volts, 50 plus 3% Hz and of 50 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. Complete in all respect as per the directions of the Engineer-in-Incharge Incoming 1 No. 125 Amps 415 volt 50 kA 4P MCCB with microprocessor release having overcurrent and short circuit protection and CBCT and ELR complete with rotary operating mechanism with spreader. Metering i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 125/5 amps 10 VA CT`s to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set Bus-bar Main bus bar rated at 200 amps 4 pole, 50 kA with heat shrinkable sleeve and shall be of aluminium. Outgoings 2 Nos. 25 amps TP, MPCB with Star Delta starter for 7.5 KW motor, with built in single phasing protection and outgoing feeder to emergency supply/exhaust Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 2 Nos. 9-13 amps TP, MPCB with DOL starter for 4 KW motor, with built in single phasing protection and outgoing feeder to emergency supply/exhaust Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor 4 Nos. 4.0-6.3 amps TP, MPCB with DOL starter for 3 KW motor, with built in single phasing protection and outgoing feeder to emergency supply/exhaust Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motorv

1

-

-

... More
Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 plus 10% volts, 50 plus 3% Hz and of 50 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. Complete in all respect as per the directions of the Engineer-in-Incharge Incoming 1 No. 25 Amps 415 volt 50 kA 4P MCCB with microprocessor release having overcurrent and short circuit protection and CBCT and ELR complete with rotary operating mechanism with spreader. Metering i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 25/5 amps 10 VA CT`s to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set Bus-bar Main bus bar rated at 50 amps 4 pole, 50 kA with heat shrinkable sleeve and shall be of aluminium. Outgoings 2 Nos. 9-13 amps TP, MPCB with DOL starter for 4 KW motor, with built in single phasing protection and outgoing feeder to emergency supply/exhaust Fan Motor. The compartment shall contain ammeter in one phase with CT. Auto/Manual selector switch along with ON/OFF/TRIP indicating lamp with MCB for ,ON, status of fan motor

1

-

-

... More
Power Cabling Supply and laying of the following 1100 volt grade armoured XLPE insulated and PVC sheathed aluminium conductor cable in trench / cable tray /clamped to wall with suitable clamps saddles and fixing bolts/including testing and commissioning complete as required. The costs shall include crimping tinned heavy duty alluminium lugs, compression glands requisite materials for all cables and to provide with 1D gap and shall be properly clamped with cable clamps and ties. Identification tags shall be provided for all cables including cable end termination.Complete in all respect as per the directions of the Engineer-in-Incharge 3.5 core 185 Sq mm

100

-

-

... More
Power Cabling Supply and laying of the following 1100 volt grade armoured XLPE insulated and PVC sheathed aluminium conductor cable in trench / cable tray /clamped to wall with suitable clamps saddles and fixing bolts/including testing and commissioning complete as required. The costs shall include crimping tinned heavy duty alluminium lugs, compression glands requisite materials for all cables and to provide with 1D gap and shall be properly clamped with cable clamps and ties. Identification tags shall be provided for all cables including cable end termination.Complete in all respect as per the directions of the Engineer-in-Incharge 3.5 core 35 Sq mm

300

-

-

... More
Power Cabling Supply and laying of the following 1100 volt grade armoured XLPE insulated and PVC sheathed aluminium conductor cable in trench / cable tray /clamped to wall with suitable clamps saddles and fixing bolts/including testing and commissioning complete as required. The costs shall include crimping tinned heavy duty alluminium lugs, compression glands requisite materials for all cables and to provide with 1D gap and shall be properly clamped with cable clamps and ties. Identification tags shall be provided for all cables including cable end termination.Complete in all respect as per the directions of the Engineer-in-Incharge 4 core 25 Sq mm

450

-

-

... More
Power Cabling Supply and laying of the following 1100 volt grade armoured XLPE insulated and PVC sheathed aluminium conductor cable in trench / cable tray /clamped to wall with suitable clamps saddles and fixing bolts/including testing and commissioning complete as required. The costs shall include crimping tinned heavy duty alluminium lugs, compression glands requisite materials for all cables and to provide with 1D gap and shall be properly clamped with cable clamps and ties. Identification tags shall be provided for all cables including cable end termination.Complete in all respect as per the directions of the Engineer-in-Incharge 4 core 16 Sq mm

450

-

-

... More
Power Cabling Supply and laying of the following 1100 volt grade armoured XLPE insulated and PVC sheathed aluminium conductor cable in trench / cable tray /clamped to wall with suitable clamps saddles and fixing bolts/including testing and commissioning complete as required. The costs shall include crimping tinned heavy duty alluminium lugs, compression glands requisite materials for all cables and to provide with 1D gap and shall be properly clamped with cable clamps and ties. Identification tags shall be provided for all cables including cable end termination.Complete in all respect as per the directions of the Engineer-in-Incharge 3 core 16 Sq mm

180

-

-

... More
Power Cabling Supply and laying of the following 1100 volt grade armoured XLPE insulated and PVC sheathed aluminium conductor cable in trench / cable tray /clamped to wall with suitable clamps saddles and fixing bolts/including testing and commissioning complete as required. The costs shall include crimping tinned heavy duty alluminium lugs, compression glands requisite materials for all cables and to provide with 1D gap and shall be properly clamped with cable clamps and ties. Identification tags shall be provided for all cables including cable end termination.Complete in all respect as per the directions of the Engineer-in-Incharge 3 core 10 Sq mm

250

-

-

... More
Power Cabling Supply and laying of the following 1100 volt grade armoured XLPE insulated and PVC sheathed aluminium conductor cable in trench / cable tray /clamped to wall with suitable clamps saddles and fixing bolts/including testing and commissioning complete as required. The costs shall include crimping tinned heavy duty alluminium lugs, compression glands requisite materials for all cables and to provide with 1D gap and shall be properly clamped with cable clamps and ties. Identification tags shall be provided for all cables including cable end termination.Complete in all respect as per the directions of the Engineer-in-Incharge 3 core 6 Sq mm

785

-

-

... More
Power Cabling Supply and laying of the following 1100 volt grade armoured XLPE insulated and PVC sheathed aluminium conductor cable in trench / cable tray /clamped to wall with suitable clamps saddles and fixing bolts/including testing and commissioning complete as required. The costs shall include crimping tinned heavy duty alluminium lugs, compression glands requisite materials for all cables and to provide with 1D gap and shall be properly clamped with cable clamps and ties. Identification tags shall be provided for all cables including cable end termination.Complete in all respect as per the directions of the Engineer-in-Incharge 3 core 4 Sq mm

3500

-

-

... More
CONTROL CABLING Supply, laying, testing and commissioning of control cabling, as per Standard specification including end termination as required. Power Cabling ( PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays). 2C x 1.5 Sq mm CONTROL CABLING Supply, laying, testing and commissioning of control cabling, as per Standard specification including end termination as required. Power Cabling ( PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays). 2C x 1.5 Sq mm

2150

-

-

... More
CONTROL CABLING Supply, laying, testing and commissioning of control cabling, as per Standard specification including end termination as required.Complete in all respect as per the directions of the Engineer-in-Incharge Power Cabling ( PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays). 2C x 2.5 Sq mm

165

-

-

... More
Electrical Cable Tray Supply and installation of following size of perforated Hot Dipped G.I. cable trays(Galvanized thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including bolts and nuts, painting suspenders etc as required.Complete in all respect as per the directions of the Engineer-in-Incharge 150 mm width X 50 mm depth X 1.6 mm thickness

425

-

-

... More
Electrical Cable Tray Supply and installation of following size of perforated Hot Dipped G.I. cable trays(Galvanized thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including bolts and nuts, painting suspenders etc as required.Complete in all respect as per the directions of the Engineer-in-Incharge 225 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
Electrical Cable Tray Supply and installation of following size of perforated Hot Dipped G.I. cable trays(Galvanized thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including bolts and nuts, painting suspenders etc as required.Complete in all respect as per the directions of the Engineer-in-Incharge 300 mm width X 50 mm depth X 1.6 mm thickness

120

-

-

... More
Electrical Cable Tray Supply and installation of following size of perforated Hot Dipped G.I. cable trays(Galvanized thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including bolts and nuts, painting suspenders etc as required.Complete in all respect as per the directions of the Engineer-in-Incharge 450 mm width X 50 mm depth X 1.6 mm thickness

150

-

-

... More
Electrical Cable Tray Supply and installation of following size of perforated Hot Dipped G.I. cable trays(Galvanized thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including bolts and nuts, painting suspenders etc as required.Complete in all respect as per the directions of the Engineer-in-Incharge 600 mm width X 50 mm depth X 1.6 mm thickness Make: Rico/Slotco/Pilco

65

-

-

... More
Earthing Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. Complete in all respect as per the directions of the Engineer-in-Incharge Make: SVS/TATA/JINDAL

12260

-

-

... More
Providing and fixing uPVC pipes confirming to IS 4985: 2000) pressure rating 6 kg/cm2 including all fittings of equivalent rating e.g. plain or door bends, junctions, cowls, offsets, access pieces etc. jointing with rubber rings and solvent cement including all MS structural steel supports fabricated from ms rods,flats,bars etc including suspending the pipes with ceiling/walls with thimble bolts (The sample of clamp/supports shall be approved by enginner incharge) complete with cutting holes in RCC/ Masonry walls and floors wherever required and making good the same complete as per specifications. (The cost of cutting holes of all sizes in RCC walls, slabs and beams wherever required including making good the same with sealents as required by the engineer-in-charge shall be included in the rate).

155

-

-

... More
Providing and fixing C.I. square Grating at terrace RWP pipe complete in all respects.150x150mm

2

-

-

... More
Providing and fixing C.I. square Grating at terrace RWP pipe complete in all respects. 225x225mm

12

-

-

... More
Providing, laying and testing CPVC Pipes of an approved make complete with CPVC fittings such as tees, crosses, plugs, sockets, elbows, reducers, unions, sleeve pieces, check nuts etc. jointed with solvent cement compound including necessary excavation and back filling etc. all complete. (pipes burried in ground). 100 mm NB (114.30mm OD) (SCH-40 ASTM F-441)

110

-

-

... More
Providing, laying and testing CPVC Pipes of an approved make complete with CPVC fittings such as tees, crosses, plugs, sockets, elbows, reducers, unions, sleeve pieces, check nuts etc. jointed with solvent cement compound including necessary excavation and back filling etc. all complete. (pipes burried in ground). 150 mm NB (168.30mm OD) (SCH-40 ASTM F-441)

110

-

-

... More
Providing, fixing and testing G.I. pipes with zinc coating of 50 to 65 DFT (medium class) of an approved make conforming to IS:1239 complete with malleable cast iron fittings as per IS:1879 such as tees, crosses, plugs, sockets, elbows, reducers, unions, sleeve pieces, check nuts etc. clamps/structural steel supports as required/directed at site including cutting and making good the walls, floors, RCC work etc. cutting chases and filling the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or cement mortar 1:4 (1 cement : 4 coarse sand) as required as per specifications. (The cost of cutting holes of all sizes in RCC walls, slabs and beams wherever required including making good the same with sealents as required by the engineer-in-charge shall be included in the rate). (For rising main from sump) 100 mm nominal bore.

510

-

-

... More
Providing, fixing and testing G.I. pipes with zinc coating of 50 to 65 DFT (medium class) of an approved make conforming to IS:1239 complete with malleable cast iron fittings as per IS:1879 such as tees, crosses, plugs, sockets, elbows, reducers, unions, sleeve pieces, check nuts etc. clamps/structural steel supports as required/directed at site including cutting and making good the walls, floors, RCC work etc. cutting chases and filling the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or cement mortar 1:4 (1 cement : 4 coarse sand) as required as per specifications. (The cost of cutting holes of all sizes in RCC walls, slabs and beams wherever required including making good the same with sealents as required by the engineer-in-charge shall be included in the rate). (For rising main from sump) 200 mm nominal bore.

170

-

-

... More
Providing, laying and jointing in position of uPVC pipes (I.S.:4985-1981) of 6 kg/cm2 rating with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers` instruction, including earth work in excavation and refilling (Earth work includes 450mm of soil cover over the pipe and width of 300mm). (For Irrigation lines). 110mm OD- 6 kg/cm²

1310

-

-

... More
Providing, laying and jointing in position of uPVC pipes (I.S.:4985-1981) of 6 kg/cm2 rating with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers` instruction, including earth work in excavation and refilling (Earth work includes 450mm of soil cover over the pipe and width of 300mm). (For Irrigation lines). 50mm OD- 6 kg/cm²

30

-

-

... More
Providing, laying and jointing in position of uPVC pipes (I.S.:4985-1981) of 6 kg/cm2 rating with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers` instruction, including earth work in excavation and refilling (Earth work includes 450mm of soil cover over the pipe and width of 300mm). (For Irrigation lines). 40mm OD- 6 kg/cm²

30

-

-

... More
Providing, laying and jointing in position of uPVC pipes (I.S.:4985-1981) of 6 kg/cm2 rating with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers` instruction, including earth work in excavation and refilling (Earth work includes 450mm of soil cover over the pipe and width of 300mm). (For Irrigation lines). 32mm OD- 8 kg/cm²

40

-

-

... More
Providing, laying and jointing in position of uPVC pipes (I.S.:4985-1981) of 6 kg/cm2 rating with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers` instruction, including earth work in excavation and refilling (Earth work includes 450mm of soil cover over the pipe and width of 300mm). (For Irrigation lines). 25mm OD- 8 kg/cm²

110

-

-

... More
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber, insertions etc. complete (The tail pieces, tapers etc if required will be paid separately). 50mm dia

13

-

-

... More
Providing and fixing medium duty circular Manhole Cover with frame size 500 mm dia, total weight 128 kg (64kg frame and 64 kg frame) complete in all respects. (For underground tanks)

14

-

-

... More
Providing and fixing GI Vent Pipe complete with 2 Nos. bends complete with mosquito proof SS wire mesh and painting with black bitumastic paint all complete as per drawing. 100 mm dia

8

-

-

... More
Providing and fixing 800mm long SS Puddle Flanges fabricated out of 6mm thick S.S. plates and SS 316 pipes along with flanges as per BS-10 (Table E) for 25mm dia pipe to 80mm dia pipes and BS-10 (Table-H) for 100mm dia to 250mm dia pipes and properly fixed in walls and top slabs of underground and overhead tanks. 25mm dia

12

-

-

... More
Providing and fixing 800mm long SS Puddle Flanges fabricated out of 6mm thick S.S. plates and SS 316 pipes along with flanges as per BS-10 (Table E) for 25mm dia pipe to 80mm dia pipes and BS-10 (Table-H) for 100mm dia to 250mm dia pipes and properly fixed in walls and top slabs of underground and overhead tanks. 32 mm dia

12

-

-

... More
Providing and fixing 800mm long SS Puddle Flanges fabricated out of 6mm thick S.S. plates and SS 316 pipes along with flanges as per BS-10 (Table E) for 25mm dia pipe to 80mm dia pipes and BS-10 (Table-H) for 100mm dia to 250mm dia pipes and properly fixed in walls and top slabs of underground and overhead tanks. 40 mm dia

10

-

-

... More
Providing and fixing 800mm long SS Puddle Flanges fabricated out of 6mm thick S.S. plates and SS 316 pipes along with flanges as per BS-10 (Table E) for 25mm dia pipe to 80mm dia pipes and BS-10 (Table-H) for 100mm dia to 250mm dia pipes and properly fixed in walls and top slabs of underground and overhead tanks. 50 mm dia

15

-

-

... More
Providing and fixing 800mm long SS Puddle Flanges fabricated out of 6mm thick S.S. plates and SS 316 pipes along with flanges as per BS-10 (Table E) for 25mm dia pipe to 80mm dia pipes and BS-10 (Table-H) for 100mm dia to 250mm dia pipes and properly fixed in walls and top slabs of underground and overhead tanks. 65 mm dia

16

-

-

... More
Providing and fixing 800mm long SS Puddle Flanges fabricated out of 6mm thick S.S. plates and SS 316 pipes along with flanges as per BS-10 (Table E) for 25mm dia pipe to 80mm dia pipes and BS-10 (Table-H) for 100mm dia to 250mm dia pipes and properly fixed in walls and top slabs of underground and overhead tanks. 80 mm dia

10

-

-

... More
Providing and fixing 800mm long SS Puddle Flanges fabricated out of 6mm thick S.S. plates and SS 316 pipes along with flanges as per BS-10 (Table E) for 25mm dia pipe to 80mm dia pipes and BS-10 (Table-H) for 100mm dia to 250mm dia pipes and properly fixed in walls and top slabs of underground and overhead tanks. 100 mm dia

20

-

-

... More
Providing and fixing 800mm long SS Puddle Flanges fabricated out of 6mm thick S.S. plates and SS 316 pipes along with flanges as per BS-10 (Table E) for 25mm dia pipe to 80mm dia pipes and BS-10 (Table-H) for 100mm dia to 250mm dia pipes and properly fixed in walls and top slabs of underground and overhead tanks. 150 mm dia

10

-

-

... More
Providing and fixing 800mm long SS Puddle Flanges fabricated out of 6mm thick S.S. plates and SS 316 pipes along with flanges as per BS-10 (Table E) for 25mm dia pipe to 80mm dia pipes and BS-10 (Table-H) for 100mm dia to 250mm dia pipes and properly fixed in walls and top slabs of underground and overhead tanks. 200 mm dia

8

-

-

... More
Providing and fixing 800mm long SS Puddle Flanges fabricated out of 6mm thick S.S. plates and SS 316 pipes along with flanges as per BS-10 (Table E) for 25mm dia pipe to 80mm dia pipes and BS-10 (Table-H) for 100mm dia to 250mm dia pipes and properly fixed in walls and top slabs of underground and overhead tanks. 250 mm dia

8

-

-

... More
Providing, fixing, testing and commissioning of Vertical in line type pump set with SS casing, SS impeller and SS shaft suitable for operation on 400/440 volts, 3 phase 2900 RPM, TEFC electric motor mounted on a common channel base plate with coupling guard, 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster complete as required. Filter Feed pumps Pump capacity - 250 lpm Head - 20 m RPM - 2900

3

-

-

... More
Providing, fixing, testing and commissioning of Vertical in line type pump set with SS casing, SS impeller and SS shaft suitable for operation on 400/440 volts, 3 phase 2900 RPM, TEFC electric motor mounted on a common channel base plate with coupling guard, 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster complete as required. Domestic water transfer pumps Pump capacity - 450 lpm Head - 50 m RPM - 2900

3

-

-

... More
Providing, fixing, testing and commissioning of Vertical in line type pump set with SS casing, SS impeller and SS shaft suitable for operation on 400/440 volts, 3 phase 2900 RPM, TEFC electric motor mounted on a common channel base plate with coupling guard, 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster complete as required. Flushing water transfer pumps Pump capacity - 500 lpm Head - 50 m RPM - 2900

2

-

-

... More
Providing, fixing, testing and commissioning of Vertical in line type pump set with SS casing, SS impeller and SS shaft suitable for operation on 400/440 volts, 3 phase 2900 RPM, TEFC electric motor mounted on a common channel base plate with coupling guard, 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster complete as required. Softener Feed pumps Pump capacity - 250 lpm Head - 20 m RPM - 2900

2

-

-

... More
Providing, fixing, testing and commissioning of Vertical in line type pump set with SS casing, SS impeller and SS shaft suitable for operation on 400/440 volts, 3 phase 2900 RPM, TEFC electric motor mounted on a common channel base plate with coupling guard, 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster complete as required. Soft water transfer pumps Pump capacity - 500 lpm Head - 50 m RPM - 2900

2

-

-

... More
Providing, fixing and commissioning non clog type stainless Steel mono block submersible drainage pumps suitable for handling solids of 12 mm size with totally water and dust proof motor. Capacity 300 lpm and Head 20m (In basement)

6

-

-

... More
Provding, installation, testing, and commissioning of Factory assembled skid mounted Variable Freqency Drive Hydropneumatic system comprising of following items.(For RO water supply) a) 2 Nos. Vertical in line pumps complete in SS coupled with TEFC motor Pump capacity - 100 lpm Head - 70 m RPM - 2900

1

-

-

... More
Providing, fixing and commissioning non clog type stainless Steel mono block submersible drainage pumps suitable for handling solids of 12 mm size with totally water and dust proof motor. Capacity 500 lpm and Head 20m (In pumproom and basement near ramp)

8

-

-

... More
Providing, fixing and commissioning non clog type stainless Steel mono block submersible drainage pumps suitable for handling solids of 12 mm size with totally water and dust proof motor. Capacity 1000 lpm and Head 15m (At site)

2

-

-

... More
Providing, fixing and commissioning non clog type stainless Steel mono block submersible drainage pumps suitable for handling solids of 12 mm size with totally water and dust proof motor. Capacity 2000 lpm and Head 15m (At site)

2

-

-

... More
Providing, fixing and commissioning non clog type stainless Steel mono block submersible sewage/effluent pumps suitable for handling solids of 32 mm size with totally water and dust proof motor. Capacity 450 lpm and Head 20m (Sewage pumps at site)

2

-

-

... More
Providing, fixing and commissioning non clog type stainless Steel mono block submersible sewage/effluent pumps suitable for handling solids of 32 mm size with totally water and dust proof motor.Capacity 400 lpm and Head 20m (Effluent pumps at site)

2

-

-

... More
Providing, fixing, testing and commissioning of Digital 5 Stage Water level Indicators/ controllers with low voltage Relays and Magnetic Analog Stainless Steel Probe operated by a single Float, including necessary wiring and conduiting from probes to display panel/motor control panels and to provide Audible Alarm for low level for each underground tank. (The cost of required cabling from probe to Display/ Control panel and from Display to Motor control panels to be paid separately). For Domestic Filter feed pumps

1

-

-

... More
Providing, fixing, testing and commissioning of Digital 5 Stage Water level Indicators/ controllers with low voltage Relays and Magnetic Analog Stainless Steel Probe operated by a single Float, including necessary wiring and conduiting from probes to display panel/motor control panels and to provide Audible Alarm for low level for each underground tank. (The cost of required cabling from probe to Display/ Control panel and from Display to Motor control panels to be paid separately). For Domestic Treated water supply pumps

1

-

-

... More
Providing, fixing, testing and commissioning of Digital 5 Stage Water level Indicators/ controllers with low voltage Relays and Magnetic Analog Stainless Steel Probe operated by a single Float, including necessary wiring and conduiting from probes to display panel/motor control panels and to provide Audible Alarm for low level for each underground tank. (The cost of required cabling from probe to Display/ Control panel and from Display to Motor control panels to be paid separately). For Flushing water tranfer pumps

1

-

-

... More
Providing, fixing, testing and commissioning of Digital 5 Stage Water level Indicators/ controllers with low voltage Relays and Magnetic Analog Stainless Steel Probe operated by a single Float, including necessary wiring and conduiting from probes to display panel/motor control panels and to provide Audible Alarm for low level for each underground tank. (The cost of required cabling from probe to Display/ Control panel and from Display to Motor control panels to be paid separately). For Flushing water tranfer pumps.

1

-

-

... More
Providing, fixing, testing and commissioning of Digital 5 Stage Water level Indicators/ controllers with low voltage Relays and Magnetic Analog Stainless Steel Probe operated by a single Float, including necessary wiring and conduiting from probes to display panel/motor control panels and to provide Audible Alarm for low level for each underground tank. (The cost of required cabling from probe to Display/ Control panel and from Display to Motor control panels to be paid separately). For HVAC Softener Feed pumps

1

-

-

... More
Providing, fixing, testing and commissioning of Digital 5 Stage Water level Indicators/ controllers with low voltage Relays and Magnetic Analog Stainless Steel Probe operated by a single Float, including necessary wiring and conduiting from probes to display panel/motor control panels and to provide Audible Alarm for low level for each underground tank. (The cost of required cabling from probe to Display/ Control panel and from Display to Motor control panels to be paid separately). For HVAC Soft water transfer pumps

1

-

-

... More
Providing, fixing, testing and commissioning of dust, damp and vermin proof, free floor standing factory built sheet steel enclosed nondrawout modular panel for water supply pumps, fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with earth bus, necessary metering protections and indications and mounted with the following including all inter connection etc. (Including earthing).Panel for water supply pumps,

1

-

-

... More
Providing, fixing, testing and commissioning of dust, damp and vermin proof, free floor standing factory built sheet steel enclosed nondrawout modular panel for water supply pumps, fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with earth bus, necessary metering protections and indications and mounted with the following including all inter connection etc. (Including earthing).Panel for water supply pumps

1

-

-

... More
Providing, fixing, testing and commissioning of dust, damp and vermin proof, wall mounted factory built sheet steel enclosed nondrawout modular panel for water supply pumps, fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with earth bus, necessary metering protections and indications and mounted with the following including all inter connection etc. (Including earthing). (For drainage pumps in pump room and basement).Panel for water supply pumps,

7

-

-

... More
Providing, fixing, testing and commissioning of dust, damp and vermin proof, wall mounted factory built sheet steel enclosed nondrawout modular panel for water supply pumps, fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with earth bus, necessary metering protections and indications and mounted with the following including all inter connection etc. (Including earthing). (For drainage pumps at site ).Panel for water supply pumps

2

-

-

... More
Supplying and laying the PVC insulated and sheathed FRLS Armoured cables of 1.1 K.V. Aluminium Conductor including supplying and making and termination with brass compression glands: 3 Core x 4 sq.mm

100

-

-

... More
Supplying and laying the PVC insulated and sheathed FRLS Armoured cables of 1.1 K.V. Aluminium Conductor including supplying and making and termination with brass compression glands: 3 Core x 6 sq.mm

700

-

-

... More
Supplying and laying the PVC insulated and sheathed FRLS Armoured cables of 1.1 K.V. Aluminium Conductor including supplying and making and termination with brass compression glands: 3 Core x 10 sq.mm

125

-

-

... More
Providing, fabricating and installation following size of perforated M.S. Cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders including painting, etc., as required.150mm width x 50mm depth x 1.6 mm thickness.

25

-

-

... More
Providing, fixing, testing and commissioning of dust, damp and vermin proof, wall mounted factory built sheet steel enclosed nondrawout modular panel for water supply pumps, fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with earth bus, necessary metering protections and indications and mounted with the following including all inter connection etc. (Including earthing). (For sewage and effluent pumps at site ).

2

-

-

... More
Providing and fixing G.I. suction and delivery headers / pipes for water supply pumps (IS:1239 heavy class) jointed with G.I. heavy class welded flanged fittings (bends, tees, reducers, plugs, flange and blank flanges etc) and clamps all complete. Note: All pipes and fittings in pump room will be weldeded flanged types.50 mm nominal bore

15

-

-

... More
Providing and fixing G.I. suction and delivery headers / pipes for water supply pumps (IS:1239 heavy class) jointed with G.I. heavy class welded flanged fittings (bends, tees, reducers, plugs, flange and blank flanges etc) and clamps all complete. Note: All pipes and fittings in pump room will be weldeded flanged types. 65 mm nominal bore

60

-

-

... More
Providing and fixing G.I. suction and delivery headers / pipes for water supply pumps (IS:1239 heavy class) jointed with G.I. heavy class welded flanged fittings (bends, tees, reducers, plugs, flange and blank flanges etc) and clamps all complete. Note: All pipes and fittings in pump room will be weldeded flanged types. 80 mm nominal bore

45

-

-

... More
Providing and fixing G.I. suction and delivery headers / pipes for water supply pumps (IS:1239 heavy class) jointed with G.I. heavy class welded flanged fittings (bends, tees, reducers, plugs, flange and blank flanges etc) and clamps all complete. Note: All pipes and fittings in pump room will be weldeded flanged types. 100 mm nominal bore

120

-

-

... More
Providing and fixing G.I. suction and delivery headers / pipes for water supply pumps (IS:1239 heavy class) jointed with G.I. heavy class welded flanged fittings (bends, tees, reducers, plugs, flange and blank flanges etc) and clamps all complete. Note: All pipes and fittings in pump room will be weldeded flanged types. 150 mm nominal bore

50

-

-

... More
Providing and fixing G.I. suction and delivery headers / pipes for water supply pumps (IS:1239 heavy class) jointed with G.I. heavy class welded flanged fittings (bends, tees, reducers, plugs, flange and blank flanges etc) and clamps all complete. Note: All pipes and fittings in pump room will be weldeded flanged types. 200 mm nominal bore

25

-

-

... More
Painting for G.I. Pipes with two or more coats of synthetic enamel paint of approved quality and shade over a coat of approved primer coat as directed including surface preparation (Shade as per pipe colour code). 50 mm nominal bore

15

-

-

... More
Painting for G.I. Pipes with two or more coats of synthetic enamel paint of approved quality and shade over a coat of approved primer coat as directed including surface preparation (Shade as per pipe colour code). 65 mm nominal bore

60

-

-

... More
Painting for G.I. Pipes with two or more coats of synthetic enamel paint of approved quality and shade over a coat of approved primer coat as directed including surface preparation (Shade as per pipe colour code). 80 mm nominal bore

45

-

-

... More
Painting for G.I. Pipes with two or more coats of synthetic enamel paint of approved quality and shade over a coat of approved primer coat as directed including surface preparation (Shade as per pipe colour code). 100 mm nominal bore

120

-

-

... More
Painting for G.I. Pipes with two or more coats of synthetic enamel paint of approved quality and shade over a coat of approved primer coat as directed including surface preparation (Shade as per pipe colour code). 150 mm nominal bore

50

-

-

... More
Painting for G.I. Pipes with two or more coats of synthetic enamel paint of approved quality and shade over a coat of approved primer coat as directed including surface preparation (Shade as per pipe colour code). 200 mm nominal bore

25

-

-

... More
Providing and fixing lever operated gun metal Ball Valve with SS ball.

19

-

-

... More
Providing and fixing Y-strainer with flanged ends with test prssure 21.09 kg/cm2. 150 mm dia

7

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. (HVAC EQUIP. SUPPLY) 3 X 6 SQMM

540

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

435

-

-

... More
Providing and fixing in position H.C.I, soil waste vent or antisyphonage pipes to I.S.I, specifications of E.L.C. Manufacture or of any other reputed firm including cutting and wastage etc. And making holes in walls, roofs or floor etc. And making good to ITS original condition but excluding cost of lead jointing. 100mm internal diameter

950

-

-

... More
Providing and fixing in position H.C.I, soil waste vent or antisyphonage pipes to I.S.I, specifications of E.L.C. Manufacture or of any other reputed firm including cutting and wastage etc. And making holes in walls, roofs or floor etc. And making good to ITS original condition but excluding cost of lead jointing. 75mm internal diameter

150

-

-

... More
Providing Lead Caulked Joints To H.C.I Pipes Specials Conforming To I.S.I Specifications of E.L.C Manufacture Or Any Other Reputed Firm Including Cost of Lead Yarn, Fuel And Tools, Etc. 100 mm internal diameter (1.13 kg)

850

-

-

... More
Providing Lead Caulked Joints To H.C.I Pipes Specials Conforming To I.S.I Specifications of E.L.C Manufacture Or Any Other Reputed Firm Including Cost of Lead Yarn, Fuel And Tools, Etc. 75 mm internal diameter (0.91 kg)

140

-

-

... More
Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S flat not less than 5 mm of the approved design for fixing C.I. Soil waste vent or anti pipes to walls complete in all respects including cutting and making good the walls and floors etc., and painting. For 100 mm internal diameter pipes

212

-

-

... More
Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S flat not less than 5 mm of the approved design for fixing C.I. Soil waste vent or anti pipes to walls complete in all respects including cutting and making good the walls and floors etc., and painting. For 75 mm internal diameter pipes

100

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. FOR 100 MM I/D PIPES

23

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. Single junction with door 100 mm x 100 mm x 100 mm

22

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. Double junction plain 100 mm x 100 mm x 100 mm x 100 mm

5

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. Single junction plain 100 mm x 100 mm x 100 mm

98

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. Bend with door

5

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. Bend plain(100 MM)

136

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. Terminal guard

23

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. Cowls

23

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. Door piece

23

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. P or S trap without vent

128

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. Collars (100 MM)

23

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. FOR 75 MM I/D PIPES

11

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. Bend plain(75 MM)

5

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. Terminal guard

11

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. Cowls

11

-

-

... More
Providing and Fixing in position h.c.i specials for soil, waste vent or anti-syphonage pipes to i.s.i marked including cutting and wastage etc., cutting holes in walls roofs or floors etc, and making good to its original condition but excluding cost of lead jointing. Collars (75 MM)

11

-

-

... More
Painting H.C.I Soil Waste Vent And Pipes And Fitting With Superior Quality Synthetic Enamel Paint in all shades on existing on new work Two Coats paints including cleaning rubbing etc. 100 mm internal diameter

385

-

-

... More
Painting H.C.I Soil Waste Vent And Pipes And Fitting With Superior Quality Synthetic Enamel Paint in all shades on existing on new work Two Coats paints including cleaning rubbing etc. 75 mm internal diameter

180

-

-

... More
Providing and fixing single unequal plain junction of required degree : 100x100x75 mm Sand cast iron SandS as per IS - 3989

10

-

-

... More
Providing, fixing and testing Cast Iron soil waste and vent pipes (IS:3989) including all fittings such as bends, junctions, inspection doors, offsets, cowls, access pieces/plugs, brass floor cleanouts plugs etc. clamps/ structural steel supports as required/directed at site, jointing with dripseal joints including cutting holes in RCC/ Masonry walls and floors wherever required and making good the same. (The cost of cutting holes of all sizes in RCC walls, slabs and beams wherever required including making good the same with sealents as required by the engineer-in-charge shall be included in the rate). 150mm dia

70

-

-

... More
Providing and fixing uPVC pipes confirming to IS 4985: 2000) pressure rating 6 kg/cm2 including all fittings of equivalent rating e.g. plain or door bends, junctions, cowls, offsets, access pieces etc. jointing with rubber rings and solvent cement including all MS structural steel supports fabricated from ms rods,flats,bars etc including suspending the pipes with ceiling/walls with thimble bolts (The sample of clamp/supports shall be approved by enginner incharge) complete with cutting holes in RCC/ Masonry walls and floors wherever required and making good the same complete as per specifications. (The cost of cutting holes of all sizes in RCC walls, slabs and beams wherever required including making good the same with sealents as required by the engineer-in-charge shall be included in the rate).(For Kitchen) 110 mm dia

40

-

-

... More
Providing and fixing uPVC pipes confirming to IS 4985: 2000) pressure rating 6 kg/cm2 including all fittings of equivalent rating e.g. plain or door bends, junctions, cowls, offsets, access pieces etc. jointing with rubber rings and solvent cement including all MS structural steel supports fabricated from ms rods,flats,bars etc including suspending the pipes with ceiling/walls with thimble bolts (The sample of clamp/supports shall be approved by enginner incharge) complete with cutting holes in RCC/ Masonry walls and floors wherever required and making good the same complete as per specifications. (The cost of cutting holes of all sizes in RCC walls, slabs and beams wherever required including making good the same with sealents as required by the engineer-in-charge shall be included in the rate).(For Kitchen) 200 mm dia

55

-

-

... More
Providing and fixing uPVC pipes confirming to IS 4985: 2000) pressure rating 6 kg/cm2 including all fittings of equivalent rating e.g. plain or door bends, junctions, cowls, offsets, access pieces etc. jointing with rubber rings and solvent cement including all MS structural steel supports fabricated from ms rods,flats,bars etc including suspending the pipes with ceiling/walls with thimble bolts (The sample of clamp/supports shall be approved by enginner incharge) complete with cutting holes in RCC/ Masonry walls and floors wherever required and making good the same complete as per specifications. (The cost of cutting holes of all sizes in RCC walls, slabs and beams wherever required including making good the same with sealents as required by the engineer-in-charge shall be included in the rate).(For Kitchen) 160 mm dia.

40

-

-

... More
Providing and fixing CP Brass floor Cleanout Plug as per drawing complete with G.I. Socket jointed to drainage pipe outlet with drip seal joint. 100mm dia

13

-

-

... More
Providing and fixing C.P. brass Double Coat Hook KOHLER Cat. No. K-15247IN-CP or equivalent make.

17

-

-

... More
Extra for depth beyond 45 cm of brick masonry chamber : For 455x610 mm size

3.5

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture`s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

270

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 450mm diameter RCC pipe.

275

-

-

... More
Providing, fixing, testing and commissioning of Vertical in line type pump set with SS casing, SS impeller and SS shaft suitable for operation on 400/440 volts, 3 phase 2900 RPM, TEFC electric motor mounted on a common channel base plate with coupling guard, 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster complete as required. Discharge : 18m3/hr. Head : 25m N.S.I RPM - 2900

2

-

-

... More
Providing and laying uPVC pipes for pumps and swimming pool piping confirming to IS 4985:2000 of pressure 6kg/cm2 with fittings i.e., bends, tees, reducers, plugs, union, flange and blank flanges etc including jointing, structural clamps, cutting chase and making good the walls, floors etc. wherever required. 90mm OD

225

-

-

... More
Providing and laying uPVC pipes for pumps and swimming pool piping confirming to IS 4985:2000 of pressure 6kg/cm2 with fittings i.e., bends, tees, reducers, plugs, union, flange and blank flanges etc including jointing, structural clamps, cutting chase and making good the walls, floors etc. wherever required. 110mm OD

200

-

-

... More
Providing and laying uPVC pipes for pumps and swimming pool piping confirming to IS 4985:2000 of pressure 6kg/cm2 with fittings i.e., bends, tees, reducers, plugs, union, flange and blank flanges etc including jointing, structural clamps, cutting chase and making good the walls, floors etc. wherever required. 160mm OD

10

-

-

... More
Supplying and laying the PVC insulated and sheathed FRLS Armoured cables of 1.1 K.V. Aluminium Conductor including supplying and making and termination with brass compression glands: 3 Core x 6 sq.mm

30

-

-

... More
Supply, erection, testing and commissioning of underground sewage treatment plant based on attached growth aerobic moving bed bio reactor technology for the following: a) N.S.I Cleaning :- Manually Cleaned Screen Bar Spacing :- 5 - 6 mm MOC :- Complete in SS 304

2

-

-

... More
Supply, installation, testing and commissioning of level controller for automatic operation of the system with high/low level alarm complete with auxillary NO/NC contacts for water tanks including all the wiring and cabling with cable tray from motor, panel and level controllers

1

-

-

... More
Supply, installation, testing and commissioning of adequate capacities of coarse air diffusers in Equalisation tank and sludge holding tank for providing aeration including Air piping shall comprise of pipes droppers/ laterals with SS 304. Header complete with all valve, fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports and clamps, etc cutting chases and making good. Contactor to submit detailed P and I indicating their proposal (Each air grid supply into above tanks will be provided with air rota meters of suitable size).

1

-

-

... More
Supply, installation, testing and commissioning of MBBR and Tube Deck Media

1

-

-

... More
Air Blowers: Twin lobe positive displacement type, rotary air blowers of suitable type with V-belt drive, belt guard, base plate, inlet filter-silencer, flexible connectors, check valve, relief valve, pressure gauge and piping.

2

-

-

... More
Providing and fixing all pipes and fittings (as described below) and isolation control valves, strainer with bypass arrangement for making the system complete.

1

-

-

... More
Sewage pumps: Supply, installation, testing and commissioning of Centrifugal type, non clog self priming pumps complete with suction and delivery valves and non return valves,suction and delivery headers of an approved make of capable of handling minimum 7 to 10mm solids size for untreated effluent with fan cooled induction motor with class `B` insulation, mounted on a common structural base plate, suitable vibration eliminated pads of approved design for pump foundation, motor to be suitable for 400/440 volts, 3 phase, 50 cycles AC supply with rpm, to suit the corresponding pumps.

1

-

-

... More
Vertical, MSRL, filter: Supply, installation, testing and commissioning of vertical MSRL filter Fabricated from IS:226/2062 plate 5mm thick for shell and 6mm thick M.S. plate for dished ends complete with initial charge of filter media, face piping and valves accessories, painting, testing and commissioning complete.

1

-

-

... More
Vertical, MSRL, activated carbon filter: Supply, installation, testing and commissioning of vertical MSRL activated carbon filter Fabricated from IS:226/2062 plate 5mm thick for shell and 8mm thick M.S. plate for dished ends complete with initial charge of filter media, face piping and valves accessories, painting, testing and commissioning complete. Iodide value of carbon = 1000

1

-

-

... More
Supply, installation, testing and commissioning of Sludge Centrifuge.

1

-

-

... More
Supply, installation, commissioning of Chorine dosing system , each electronic metering pump of 0-6 litres/ hr. capacity with individual HDPE tanks of 200 ltrs capacity having , solution delivery tube etc. including making electrical connection all in complete.

1

-

-

... More
Supply, installation, commissioning of Poly dosing system , each electronic metering pump of 0-12 litres/ hr. capacity with individual HDPE tanks of 200 litres capacity having , solution delivery tube etc. including making electrical connection all in complete.

1

-

-

... More
Supply, installation, testing and commissioning of U.V. sterlizer with S.S. housing. U.V.lamp, glass tube and all other accessories as per manufacturer`s specification with cleaning arrangement, supports, inlets, outlet bypass connections and U.V. monitor including S.S. cabinet with glass door of suitable size to house the U.V. sterilizer. The entire assembly shall be mounted on wall (Suitable for STP treated water).

1

-

-

... More
Supply, installation, testing and commissioning of EM type flow meter. The signal from read out shall be 4-20 m.amps to be received as BAS. Suitable for flow rate 10000 lit/hr. (For sewage feed pump outlet)

1

-

-

... More
Supply, installation, testing and commissioning of EM type flow meter. The signal from read out shall be 4-20 m.amps to be received as BAS. Suitable for flow rate 13000 lit/hr. (For ACF outlet)

1

-

-

... More
Supply, installation, testing and commissioning of Centrifugal type, non clog self priming pumps complete with suction and delivery valves and non return valves,suction and delivery headers of an approved make of capable of handling minimum 7 to 10mm solids size for untreated effluent with fan cooled induction motor with class `B` insulation, mounted on a common structural base plate, suitable vibration eliminated pads of approved design for pump foundation, motor to be suitable for 400/440 volts, 3 phase, 50 cycles AC supply with rpm, to suit the corresponding pumps. Sludge screw pump Capacity 1.5 cum/hr each Head 40 Mts RPM 2900

2

-

-

... More
Supply, installation, testing and commissioning of Centrifugal type, non clog self priming pumps complete with suction and delivery valves and non return valves,suction and delivery headers of an approved make of capable of handling minimum 7 to 10mm solids size for untreated effluent with fan cooled induction motor with class `B` insulation, mounted on a common structural base plate, suitable vibration eliminated pads of approved design for pump foundation, motor to be suitable for 400/440 volts, 3 phase, 50 cycles AC supply with rpm, to suit the corresponding pumps. Sluge Transfer pumps Capacity 4.0 cum/hr each Head 10 Mts RPM 2900

2

-

-

... More
Supply, installation, testing and commissioning of Centrifugal type, monoblock, self priming pumps with bronze in impeller of an approved make and complete with with suction and delivery valves and non return valves,suction and delivery headers capable of handling clear water complete with fan cooled induction motor with class B insulation, mounted on a common structural base plate with 100mm dia pressure gauge with gunmetal isolation cock and suitable vibration elimination pads of approved design for pump foundation. Motor to be suitable for 400/440 volts, 3 phase, 50 cycle AC supply with rpm, to suit the corresponding pumps. a) Filter feed pumps Capacity 13 cum/hr each Head 30 Mts RPM 2900

2

-

-

... More
Supply, installation, testing and commissioning of Centrifugal type, monoblock, self priming pumps with bronze in impeller of an approved make and complete with with suction and delivery valves and non return valves,suction and delivery headers capable of handling clear water complete with fan cooled induction motor with class B insulation, mounted on a common structural base plate with 100mm dia pressure gauge with gunmetal isolation cock and suitable vibration elimination pads of approved design for pump foundation. Motor to be suitable for 400/440 volts, 3 phase, 50 cycle AC supply with rpm, to suit the corresponding pumps. Treated water transfer pumps Capacity 18 cum/hr each Head 30 Mts RPM 2900

2

-

-

... More
Provding, installation, testing, and commissioning of Factory assembled skid mounted Variable Freqency Drive Hydropneumatic system comprising of following items. (Irrigation water supply).

1

-

-

... More
Providing and fixing S.S. puddle flanges fabricated of SS-316 pipe with flanged ends pieces fixed to R.C.C. water tanks wall / slab.

1

-

-

... More
Providing and fixing M.S. structural work fabricated from structural steel sections M.S. rounds, angles, channels, girder, pulley, tees, square bars, plates including cutting of required sizes, drilling, welding fixing and welding to insert plates in RCC structural works, as directed by Architects / Consultant. M.S. ladders, tank covers and frame etc. cutting and making good the wall and floor where ever required including two coats of synthetic enamel paint/epoxy paint over a coat of primer.

1

-

-

... More
Supply, installation, testing and commissioning of Intrumentation comprising of the following items.

2

-

-

... More
Supply, installation, testing and commissioning of 2 Nos. submersible non clog drainage sump pumps, with 3 phase motor, CI Casing, CI Impeller,and SS Shaft with all necessary protection and the mechanical seal etc. including electrical starter panel for both pumps, cabling upto motor as per manufacturer specifications. Automation and dry protection of pumps by float level switch complete as required including each compartment shall contain direct operated digital ammeter of 0-32 amps range, auto/manual selector switch and indicating lamps with MCB’s and ‘ON/OFF/TRIP’ status of motor. Location: STP plant room Flow rate: 300 LPM Head: 15 Mts N.S.I Solid Handling: 18-20mm

1

-

-

... More
10.22.1 Electrical panel: Supply, installation, testing and commissioning of Dust, damp and vermin proof, free floor standing factory built sheet steel enclosed nondrawout modular panel for sewage treatment plant, fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with earth bus, necessary metering protections and indications and mounted with the following including all inter connection cables etc. (Including earthing). (Indoor type)

1

-

-

... More
ULTRA FILTARTION PLAN Supply, installation, testing and commissioning of UF plant of capacity 12.0 cum/hr complete with all interconnecting pipes and valves with all the required accessories and chemical cleaning system, complete in all respects and comprising the following:

1

-

-

... More
Approval: Contractor to provide adequacy report consisting of inlet and outlet test reports, report/drawings as per pollution board requirement. Contractor shall include the cost of all chemicals consumed during testing and commissioning and the cost of such items of works, which are not explicitly mentioned above. All required statuary approvals shall be included in the rates.

1

-

-

... More
Opertaion and Maintenance contract of STP for a period of one year after completion of one year defect liability period after commissioning. All spares and replacement of any defective part shall be included in the contract.

1

-

-

... More
Supply, erection, testing and commissioning of underground Effluent treatment plant based on attached growth aerobic moving bed bio reactor technology for the following:

2

-

-

... More
Supply, installation, testing and commissioning of adequate capacities of coarse air diffusers in Equalisation tank and sludge holding tank for providing aeration including Air piping shall comprise of pipes droppers/ laterals with SS 304. Header complete with all valve, fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports and clamps, etc cutting chases and making good. Contactor to submit detailed P and I indicating their proposal (Each air grid supply into above tanks will be provided with air rota meters of suitable size). .

1

-

-

... More
Supply, installation, testing and commissioning of MBBR and Tube Deck Media.

1

-

-

... More
Providing and fixing all pipes and fittings (as described below) and isolation control valves, strainer with bypass arrangement for making the system complete..

1

-

-

... More
Sludge pumps: Supply, installation, testing and commissioning of Centrifugal type, non clog self priming pumps complete with suction and delivery valves and non return valves,suction and delivery headers of an approved make of capable of handling minimum 7 to 10mm solids size for untreated effluent with fan cooled induction motor with class `B` insulation, mounted on a common structural base plate, suitable vibration eliminated pads of approved design for pump foundation, motor to be suitable for 400/440 volts, 3 phase, 50 cycles AC supply with rpm, to suit the corresponding pumps.

1

-

-

... More
Air Blowers: Twin lobe positive displacement type, rotary air blowers of suitable type with V-belt drive, belt guard, base plate, inlet filter-silencer, flexible connectors, check valve, relief valve, pressure gauge and piping. Capacity- 130m3/hr @ 6000 MMWG

2

-

-

... More
Vertical, MSRL, filter: Supply, installation, testing and commissioning of vertical MSRL filter Fabricated from IS:226/2062 plate 5mm thick for shell and 6mm thick M.S. plate for dished ends complete with initial charge of filter media, face piping and valves accessories, painting, testing and commissioning complete. Multigrade pressure sand filter Flow rate : 10000 LPH Filtration Rate: 13.5m3/hr/m2

1

-

-

... More
Vertical, MSRL, activated carbon filter: Supply, installation, testing and commissioning of vertical MSRL activated carbon filter Fabricated from IS:226/2062 plate 5mm thick for shell and 8mm thick M.S. plate for dished ends complete with initial charge of filter media, face piping and valves accessories, painting, testing and commissioning complete. Iodide value of carbon = 1000 Activated Carbon Filter Flow rate : 10000 LPH Filtration Rate: 13.5m3/hr/m2

1

-

-

... More
Supply, installation, commissioning of Acid dosing system , each electronic metering pump of 0-6 litres/ hr. capacity with individual HDPE tanks of 200 ltrs capacity having , solution delivery tube etc. including making electrical connection all in complete.

1

-

-

... More
Supply, installation, commissioning of Alum dosing system , each electronic metering pump of 0-6 litres/ hr. capacity with individual HDPE tanks of 200 ltrs capacity having , solution delivery tube etc. including making electrical connection all in complete.

1

-

-

... More
Supply, installation, commissioning of Polyelectrolyte dosing system , each electronic metering pump of 0-6 litres/ hr. capacity with individual HDPE tanks of 200 ltrs capacity having , solution delivery tube etc. including making electrical connection all in complete.

1

-

-

... More
Flash mixture:-Flash mixture of rpm not exceeding 90 with SS shaft and SS impellers, propellor, type for RCC Flash mixture tank with mounting structures with TEFC IP 55 motor or suitable rating. Complete with reduction gear and other accessories.

1

-

-

... More
Flocculator:-Flocculator paddle of rpm not exceeding 20 with SS shaft and SS impellers for RCC floculator tank with mounting structures with TEFC IP 55 motor of suitable rating complete with reduction gear and other accessories.

1

-

-

... More
Supply, installation, testing and commissioning of U.V. sterlizer with S.S. housing. U.V.lamp, glass tube and all other accessories as per manufacturer`s specification with cleaning arrangement, supports, inlets, outlet bypass connections and U.V. monitor including S.S. cabinet with glass door of suitable size to house the U.V. sterilizer. The entire assembly shall be mounted on wall (Suitable for ETP treated water).

1

-

-

... More
Supply, installation, testing and commissioning of Centrifugal type, monoblock, self priming pumps with bronze in impeller of an approved make and complete with with suction and delivery valves and non return valves,suction and delivery headers capable of handling clear water complete with fan cooled induction motor with class B insulation, mounted on a common structural base plate with 100mm dia pressure gauge with gunmetal isolation cock and suitable vibration elimination pads of approved design for pump foundation. Motor to be suitable for 400/440 volts, 3 phase, 50 cycle AC supply with rpm, to suit the corresponding pumps. Filter feed pumps Capacity 10 cum/hr each Head 25 Mts RPM 2900

2

-

-

... More
Supply, installation, testing and commissioning of Centrifugal type, monoblock, self priming pumps with bronze in impeller of an approved make and complete with with suction and delivery valves and non return valves,suction and delivery headers capable of handling clear water complete with fan cooled induction motor with class B insulation, mounted on a common structural base plate with 100mm dia pressure gauge with gunmetal isolation cock and suitable vibration elimination pads of approved design for pump foundation. Motor to be suitable for 400/440 volts, 3 phase, 50 cycle AC supply with rpm, to suit the corresponding pumps. Treated water transfer pumps Capacity 12 cum/hr each Head 40 Mts RPM 2900

2

-

-

... More
Centrifuge Feed Pumps: Centrifugal type, non clog self priming pumps complete with valves, suction and delivery header of an approved make of suitable capacity capable of handling 8-10 mm size solids for untreated effluent mounted on a base plate, suitable vibration eliminated pads of approved design for pump foundation, motor to be suitable for 400/440 volts, 3 phase, 50 cycles AC supply with rpm, to suit the corresponding pumps.

2

-

-

... More
Basket Centrifuge, top discharge type for sludge dewatering suitable for 100 KLD ETP.

1

-

-

... More
Providing and fixing S.S. puddle flanges fabricated of SS-316 pipe with flanged ends pieces fixed to R.C.C. water tanks wall / slab. .

1

-

-

... More
Providing and fixing M.S. structural work fabricated from structural steel sections M.S. rounds, angles, channels, girder, pulley, tees, square bars, plates including cutting of required sizes, drilling, welding fixing and welding to insert plates in RCC structural works, as directed by Architects / Consultant. M.S. ladders, tank covers and frame etc. cutting and making good the wall and floor where ever required including two coats of synthetic enamel paint/epoxy paint over a coat of primer..

1

-

-

... More
Supply, installation, testing and commissioning of 2 Nos. submersible non clog drainage sump pumps, with 3 phase motor, CI Casing, CI Impeller,and SS Shaft with all necessary protection and the mechanical seal etc. including electrical starter panel for both pumps, cabling upto motor as per manufacturer specifications. Automation and dry protection of pumps by float level switch complete as required including each compartment shall contain direct operated digital ammeter of 0-32 amps range, auto/manual selector switch and indicating lamps with MCB’s and ‘ON/OFF/TRIP’ status of motor. Location: ETP plant room Flow rate: 300 LPM Head: 15 Mts N.S.I Solid Handling: 18-20mm

1

-

-

... More
Electrical panel: Supply, installation, testing and commissioning of Dust, damp and vermin proof, free floor standing factory built sheet steel enclosed nondrawout modular panel for sewage treatment plant, fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with earth bus, necessary metering protections and indications and mounted with the following including all inter connection cables etc. (Including earthing). (Indoor type)

1

-

-

... More
Opertaion and Maintenance contract of ETP for a period of one year after completion of one year defect liability period after commissioning. All spares and replacement of any defective part shall be included in the contract.

1

-

-

... More
Effluent pumps: Supply, installation, testing and commissioning of Centrifugal type, non clog self priming pumps complete with suction and delivery valves and non return valves,suction and delivery headers of an approved make of capable of handling minimum 7 to 10mm solids size for untreated effluent with fan cooled induction motor with class `B` insulation, mounted on a common structural base plate, suitable vibration eliminated pads of approved design for pump foundation, motor to be suitable for 400/440 volts, 3 phase, 50 cycles AC supply with rpm, to suit the corresponding pumps..

1

-

-

... More
Approval: Contractor to provide adequacy report consisting of inlet and outlet test reports, report/drawings as per pollution board requirement. Contractor shall include the cost of all chemicals consumed during testing and commissioning and the cost of such items of works, which are not explicitly mentioned above. All required statuary approvals shall be included in the rates..

1

-

-

... More
Providing and fixing SWR uPVC pipes (Type-B) confirming to IS 13592 : 1992 complete with all fittings e.g. plain or door bends, junctions, cowls, offsets, access pieces etc. jointing with rubber rings and solvent cement including fixing the pipes on wall face with MS galvanized holder bat clamps or suspended below ceiling with MS galvanized hangers/supports and fasteners all as approved by the engineer in charge including Cutting holes in walls, floors excavation, refilling and disposal of surplus earth wherever required and making good . The rates shall be inclusive of painting of all supports and clamps with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation.(Sample of holder bat clamps,hangers / supports to be approved by the Engineer-in-Charge.)

80

-

-

... More
Supply, installation, testing and commissioning of level controller for automatic operation of the system with high/low level alarm complete with auxillary NO/NC contacts for water tanks including all the wiring and cabling with cable tray from motor, panel and level controllers.

1

-

-

... More
Above ground Piping: Supplying, installing and testing and commissioning above ground Mild Steel Pipe of Heavy class ERW of following sizes conforming to IS 1239 and IS 3589 with one coat of zinc Chromite primer and two coats of fire red enamel paint as per IS-5 Shade 536, etc. as per specifications. along with necessary fittings (elbows, tees, reducers,bends, u clambs, beam clambs and adoptor,anchor fastner, GI/MS rods, flats,nuts washers, threaded rod etc to complete the requirement) painted with enamel paint, pipes to be duly tested to 1.5 times of working pressure, in an approved manner as per given drawings, specifications and instruction of the engineer in charge. Fittings shall be SOCKET WELD TYPE upto 50 mm and butt weld type for 65 mm and above. 80 mm dia

30

-

-

... More
Above ground Piping: Supplying, installing and testing and commissioning above ground Mild Steel Pipe of Heavy class ERW of following sizes conforming to IS 1239 and IS 3589 with one coat of zinc Chromite primer and two coats of fire red enamel paint as per IS-5 Shade 536, etc. as per specifications. along with necessary fittings (elbows, tees, reducers,bends, u clambs, beam clambs and adoptor,anchor fastner, GI/MS rods, flats,nuts washers, threaded rod etc to complete the requirement) painted with enamel paint, pipes to be duly tested to 1.5 times of working pressure, in an approved manner as per given drawings, specifications and instruction of the engineer in charge. Fittings shall be SOCKET WELD TYPE upto 50 mm and butt weld type for 65 mm and above. 100 mm dia

30

-

-

... More
Above ground Piping: Supplying, installing and testing and commissioning above ground Mild Steel Pipe of Heavy class ERW of following sizes conforming to IS 1239 and IS 3589 with one coat of zinc Chromite primer and two coats of fire red enamel paint as per IS-5 Shade 536, etc. as per specifications. along with necessary fittings (elbows, tees, reducers,bends, u clambs, beam clambs and adoptor,anchor fastner, GI/MS rods, flats,nuts washers, threaded rod etc to complete the requirement) painted with enamel paint, pipes to be duly tested to 1.5 times of working pressure, in an approved manner as per given drawings, specifications and instruction of the engineer in charge. Fittings shall be SOCKET WELD TYPE upto 50 mm and butt weld type for 65 mm and above. 150 mm dia

30

-

-

... More
Under Ground Piping : Supplying, installing and testing and commissioning MS Pipe of Heavy class ERW of following sizes conforming to IS 3589 with all accessories like fittings including tees,elbows,reducers,union,flanges, nuts bolts etc including excavation in all kinds of soil and refilling including bed preparation the trench all complete. Pipes to be laid underground in 1 mtr below from ground including concrete anchor blocks (thrust block) at all change in direction of pipeline and also near each joints complete as required as per approved layouts or as instructed by engineer in-charge. Pipes to be duly tested to 1.5 times of working pressure, in an approved manner as per given drawings ,specifications and instruction of the engineer in charge including protection of pipes by wrapping and coating with 4 mm thick tape as per IS:10221 complete as required as per approved layouts or as instructed by engineer incharge in line with the specifications. Fittings shall be SOCKET WELD TYPE upto 50 mm and butt weld type for 65 mm and above.

420

-

-

... More
Providing and fixing full bore type flow switch suitable for minimum 60 lpm flow rate

3

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 2.5 sq. mm

600

-

-

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : 2280 lpm at 70 m Head

1

-

-

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) 2280 lpm at 70 m Head

1

-

-

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) 180 lpm at 70 m Head

1

-

-

... More
INCOMING 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich and CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump `200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.` Jockey Pump 100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. `Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications. `

1

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

1

-

-

... More
Supplying, filling, spreading and leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge.

32

-

-

... More
Supplying, filling, spreading and leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer –in-charge.

32

-

-

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineer-in-charge

32

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

48

-

-

... More
Supplying, Installation, Testing and Commissioning of 20 passenger (1360 Kg) Machine room less gearless Elevator having contract speed of 1.5 Meter per second serving different floors in the lift shaft as per detailed specifications attached and as under complete with all the equipment and accessories.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.