Dedicated Freight Corridor Corporation Of India Limited Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Dedicated Freight Corridor Corporation Of India Limited - DFCCIL Tender

Goods
Electrical and Electronics
Electrical Works
Ireps
Opening Date18 Dec 2023
Closing Date8 Jan 2024
Tender Amount₹ 11,09,81,279.64 
Notes
Download

Costs

Summary

Maintenance Of 2x25kv Over Head Equipment, Psi Equipment And E&m Maintenance Of new Pilkhani - Sahnewal Section Of Dfccil Including The Link Lines, Connecting Chords Of dfccil With Indian Railways For A Period Of 24 (twenty-four) Months Period.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Call bells buzzer Ding/dong

133

46

6204.45

... More
Single pole MCB 6A-32A

67

34

2321.55

... More
Double pole MCB 6A-32A

67

111

7437

... More
Fan regulator electronics 100 watt

67

39

2613

... More
Condenser 2.5 mfd, 440V

67

5

351.75

... More
6A Angle holder

67

5

341.7

... More
6A Batten holder

67

5

341.7

... More
DIN Type HRC fuse 63 Amp

13

57

750.75

... More
FRLS PVC insulated industrial cable 2.5 Sq. mm Multi strand copper

600

7

4278

... More
FRLS PVC insulated industrial cable 4 Sq. mm Multi strand copper

600

10

6282

... More
FRLS PVC insulated industrial cable 6 Sq. mm Multi strand copper

600

15

9384

... More
FRLS PVC insulated industrial cable 10 Sq. mm Multi strand copper

167

26

4433.85

... More
PVC conduit pipe 25 mm dia

133

3

518.7

... More
Box type PVC casing caping (6 ft length) Size 25x16mm

133

3

498.75

... More
6A modular type one way switch

100

6

675

... More
16A modular one-way switch

100

20

2055

... More
6A 3 Pin modular socket

67

19

1326.6

... More
6A/16A modular socket

67

31

2090.4

... More
Aluminum lug: 25 Sq. mm long barrel

33

-

30.69

... More
Aluminum lug: 35 Sq. mm long barrel

33

1

49.17

... More
Aluminum lug: 50 Sq. mm long barrel

33

2

70.95

... More
Aluminum lug: 70 Sq. mm long barrel

33

3

108.9

... More
Aluminum lug: 120 Sq. mm long barrel

33

5

178.2

... More
Aluminum lug: 185 Sq. mm long barrel

33

8

287.1

... More
Aluminum lug: 240 Sq. mm long barrel

33

13

440.55

... More
Aluminum lug: 25 Sq. mm short barrel

33

-

21.78

... More
Aluminum lug: 35 Sq. mm short barrel

33

-

32.67

... More
Aluminum lug: 50 Sq. mm short barrel

33

1

50.49

... More
Aluminum lug: 70 Sq. mm short barrel

33

2

76.23

... More
Aluminum lug: 120 Sq. mm short barrel

33

4

138.6

... More
Aluminum lug: 240 Sq. mm short barrel

33

10

356.4

... More
Copper Lug: 4 Sq. mm

33

-

32.67

... More
opper lug: 6 Sq. mm

33

1

36.3

... More
Copper lug: 10 Sq. mm

33

1

45.21

... More
Copper lug: 50 Sq. mm long barrel

13

14

189.15

... More
Copper lug: 70 Sq. mm long barrel

13

23

304.2

... More
50 Sq. mm short barrel lug

7

10

71.4

... More
Copper lug: 70 Sq. mm short barrel

7

16

113.4

... More
Copper Lug: 2.5 Sq. mm Pin type

67

20

1340

... More
Copper lug: 6 Sq. mm Pin type

67

20

1340

... More
LED tube light 18 W

33

598

19765.35

... More
LED tube light 36 W

33

890

29370

... More
LED tube light 40 W

33

1377

45457.5

... More
Bulkhead light 10 W

13

499

6499.74

... More
LED Panel light 30 W

13

1979

25727

... More
LED Panel light 36 W

13

5500

71500

... More
Pole mounted 90 W

13

10800

140400

... More
120 W flood light

13

6500

84500

... More
150 W flood light

13

7600

98800

... More
70 W LED Street light

13

3550

46150

... More
120 W LED Street light

13

11895

154635

... More
150 W LED Street light

13

13500

175500

... More
Earthing with 40 mm dia. Gl pipe class B. 3-meter-long earth erected as per IS 3044/1985b (latest 2 version) to achieve earth resistance less than 5 ohms, including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement (approx. Size 400 x400 mm) on top, connection from earth electrode to switch gear/pole as per drawing.

6.67

488

3259.83

... More
Horizontal boring under railway track/road for laying 120mm dia. DWC double walled corrugated pipes at the depth of 1.4meter to 2.1 meter from formation level (level of earth below ballast) as per drawing and directed by engineer in-charge by trenchless technology excluding the cost of DWC pipes.

333.33

225

75299.25

... More
Comprehensive running maintenance of split/window/tower type AC units of 1.5/2.0 Ton capacity installed at DFCCIL Stations, IMD, IMSDs, RHs & CGM/UMB office for 03 years (07 months in a year March to September in each year as per maintenance schedule 'M' 'O' & 'P") as per scope of work.

4494

83

375069.24

... More
Complete repairing and overhauling of tower/window/split type AC units (described in item no 1) during switching off period i.e., November to February as per technical specification & as per scope of work.

256

392

100587.52

... More
Checking and maintenance of 2*25 kV OHE conductors

566

3223760

3223760.54

... More
Checking & maintenance of all type of 2*25 KV OHE Jumpers

2800

520

1458212

... More
Checking & maintenance of Overlaps (IOL) & (UIOL)

600

1898

1139376

... More
Checking & Maintenance of Anti Creep arrangement

558

1424

794709.18

... More
Checking & Maintenance of 2*25 KV Isolator (SP/DP) including earthing heel arrangement if any

552

1523

840927.84

... More
Checking & Maintenance of 2*25 KV OHE at Turnouts

458

1460

669060.14

... More
Checking & Maintenance of 2*25 KV OHE on a cross over

458

2919

1337039.4

... More
Checking & Maintenance of Section Insulator Assembly

912

1460

1332276.96

... More
Checking & Maintenance of Auto tension Device (ATD)

1116

3084

3442447.08

... More
Checking & Maintenance of Aerial earth wire, Feeder wire & Feeder Termination / Fixed Anchor Termination Per Track

350

11

4133.5

... More
Maintenance of all type of bonds and clamps including cleaning of muffs at OHE mast (Structure/ /longitudinal/transverse bonds & earth electrode)

30000

34

1027200

... More
Removal & Re erection of bonds of various type during track machine working or Erection of missing/new bonds Paint etc. supplied by DFC)

200

88

17714

... More
Checking & Maintenance of all additional Insulators (other than feeder suspension insulators, cantilever insulators & termination insulators)

200

406

81250

... More
Checking & maintenance of leaning of OHE mast till a new mast erected

67

4061

272105.09

... More
Checking & Maintenance of PTFE type neutral section (Quarterly)

112

6191

693468.16

... More
Checking and Maintenance of Portal boom drop arms and fabricated Masts free from bird nests.

160

453

72558.4

... More
Trimming of tree branches

200

30

6140

... More
Erection of 2*25 KV overhead equipment as per requirement

20

49285

985710.4

... More
Loading, unloading of DFCCIL supplied material to places directed by Engineer incharge (i.e. From station to tower wagon, station to station etc.)

100

4599

459978

... More
Erection of Catenary wire splicing or Contact wire splicing.

40

3553

142138.4

... More
Replacement / Re-erection of various types of insulators

133

1015

135076.13

... More
Breakdown attention by a gang for restoration of 2*25 KV OHE during accidents/ unusual occurance for checking OHE parameters- (one gang consisting of 7 staff)

160

1800

288150.4

... More
Erection of traction masts & portal

53

3357

177943.26

... More
Casting of all types of foundation (The rate includes supply of the material- ballast, sand, cement, mixture & reinforcement etc.)

100

8485

848509

... More
Counter weight piece (40KG) base with hook (RI NO: 5091

7

1617

11320.19

... More
Counterweight piece (40KG) (RI 5092)

13

1617

21023.21

... More
Counterweight piece (20 KG) (RI 5093)

13

808

10511.54

... More
Counterweight plate (5 kg) (RI NO: 5098)

7

600

4206.79

... More
Counterweight Guide tubes (5.60m long) (RI NO: 5063-1 & 5067)

33

1643

54249.03

... More
Counterweight eye rod 1300mm long with GS nut M20, Washer and annealed copper split pin 4x40 (RI NO: 5095)

13

566

7358.13

... More
9 Tonne adjuster complete with Both side eye (5020)

7

710

4971.68

... More
Anchor Double strap (set of 2 nos of 5031) (RI NO: 5030) complete with nut, bolt, washer & split pin.

13

202

2627.95

... More
Typical Structural number plate (125mm size) ((RI No 7503) Size: 310mm x 340mm x 2mm

33

524

17308.17

... More
Contact wire parallel clamp Large with SS bolt and nut 16x50/38 MM and spring washer B-16 as per RDSO Drg No ETI/OHE/P/1030-2 (Mod-D)

13

265

3451.76

... More
Contact wire parallel clamp (part 2 Nos of 1031-3) (RI NO 1030-3) (157-65/107/150)

13

535

6960.33

... More
Contact wire parallel clamp small Part no 1041-2 with fasteners Drg no ETI/OHE/P/1040-2 (Mod-E)

13

265

3451.76

... More
Parallel Clamp (150/105 - 150) RI No: 1050-2

13

535

6960.33

... More
105 Sqmm Large jumper wire annealed copper wire.

133

655

87196.13

... More
50 Sqmm flexible copper jumper wire.

200

287

57476

... More
Porcelain 9-Tonne Insulators RI - 6020 (1050MM CD) RDSO specification TI/SPC/ OHE/INS/0070(04/2007)

67

3551

237931.07

... More
Large suspension clamp to suit 288sqmm AAAC feeder wire (22.05 mm dia) complete assembly with armour tape and ferrule (RI No 1580)

7

1081

7572.25

... More
Lug to suit 91.97 sqmm Aerial Earth wire.

13

191

2488.59

... More
93.3 Sqmm ACSR Earth wire splice (ALSTOM-705115)

13

1961

25501.19

... More
160 sqmm Large jumper annealed flexible copper wire.

133

985

131084.8

... More
Post Insulator Jumper Clamp (set of 2 nos) (RI NO: 6094)

13

300

3906.37

... More
Terminal Connector (19mm) Multiple hole (bolted type) RINO:1009

13

1748

22727.77

... More
Structure bonds/L-Bond

133

672

89481.07

... More
Single earth electrode

33

2983

98451.54

... More
GS Snap Head Pin 14x122 mm

133

32

4359.74

... More
GS Snap Pin 16x50 mm

667

38

25506.08

... More
GS Split Pin 4x32 mm

667

6

4008.67

... More
GS Split Pin 4x36mm

667

6

4375.52

... More
Anchor V Bolt

7

338

2371.11

... More
Anchor Bolt

7

333

2332.89

... More
Anchor Loop

7

1584

11090.73

... More
GS Bolt 16x50/30 mm with Nut & Flat washer

333

30

10189.8

... More
GS Bolt 16x50/38 mm with Nut & Flat washer

667

30

20410.2

... More
Copper Split Pin 2.5x25 mm

3333

4

14565.21

... More
Copper Split Pin 4x36 mm

3333

9

32763.39

... More
GS 'J' Bolt 16 mm with Nut & flat Washer

67

45

3074.63

... More
GS Bolt 12x100/30 with Nut, Locknut & Flat Washer

33

21

721.05

... More
GS Bolt 12x55/30 with Nut, Locknut & Flat Washer

33

18

612.81

... More
GS Bolt 12x75/30 with Nut, Locknut & Flat Washer

33

19

649.11

... More
GS Bolt 12x50/35with Nut, Locknut & Flat Washer

33

24

793.32

... More
GS Bolt 12x200/49 with Nut & Spring washer

67

38

2562.08

... More
GS Bolt 16x40/32 with Nut, Locknut & Spring Washer

67

28

1903.47

... More
GS Bolt 16x220/57 with Nut, Locknut & Flat Washer

67

60

4026.7

... More
GS Bolt 16x260/57 with Nut, Locknut & Flat washer

67

65

4392.52

... More
GS Bolt 16x300/57 with Nut, Locknut & Flat Washer

67

92

6222.96

... More
GS Bolt 16x360/57 with Nut, Locknut & Flat Washer

67

103

6954.6

... More
GS Bolt 20x65/46 with Nut, Locknut & tapered washer

67

46

3148.33

... More
GS Bolt 20x75/45 with Nut Lock nut & Tapered Washer

67

51

3440.45

... More
GS Bolt 16x175/44 with Nut, Lock nut & Tapered Washer

67

52

3514.15

... More
GS Bolt 16x210/57 with Nut, Locknut & Flat Washer

67

57

3879.97

... More
GS Bolt 10x50/26 with Nut & Flat Washer

67

16

1098.13

... More
GS Bolt 16x260/100 With Nut, Locknut

67

62

4172.76

... More
GS Bolt 16x320/100 with Nut, Locknut

67

87

5856.47

... More
GS bolt 20x50/37 with Nut, Locknut & Flat Washer

67

45

3074.63

... More
GS bolt 20x260/65 with Nut, Locknut & Flat Washer

67

103

6954.6

... More
GS bolt 20x280/65 with Nut, Locknut & Flat Washer

67

109

7321.09

... More
GS bolt 20x330/65 with Nut, Locknut & Flat Washer

67

142

9517.35

... More
GS bolt 16x360/100 with Nut, Locknut & Flat Washer

67

103

6954.6

... More
GS bolt 24x70/54 with Nut, Locknut & Copper Split Pin 5x40 mm

67

76

5124.83

... More
Monthly Maintenance of 220/132 kV, 75/105/150 MVA Power Transformer.

40

1169

46785.2

... More
Half yearly Maintenance of 220/132 kV, 75/105/150 MVA Power Transformer.

4

1565

6260.44

... More
Yearly Maintenance of 220/132 kV, 75/105/150 MVA Power Transformer.

4

2446

9786.12

... More
Monthly Maintenance of 132/55kV, 30/42/50 MVA Traction Transformer.

60

1169

70177.8

... More
Half yearly Maintenance of 132/55kV, 30/42/50 MVA Traction Transformer.

6

1565

9390.66

... More
Yearly Maintenance of 132/55kV, 30/42/50 MVA Traction Transformer.

6

2446

14679.18

... More
Monthly Maintenance of 220/55kV 30/42/50 MVA Traction Transformer.

100

1169

116963

... More
Half yearly of 220/55kV 30/42/50 MVA Traction Transformer.

10

1565

15651.1

... More
Yearly of 220/55kV 30/42/50 MVA Traction Transformer.

10

2446

24465.3

... More
Monthly Maintenance of 132/220kV TP/DP SF-6 Circuit Breaker

380

782

297369

... More
Half Yearly Maintenance of 132/220kV TP/DP SF-6 Circuit Breaker

38

1219

46324.28

... More
Yearly Maintenance of 132/220kV TP/DP SF-6 Circuit Breaker

25

1466

36656

... More
Three Yearly Maintenance of 132/220kV TP SF-6 Circuit Breaker

13

1755

22825.14

... More
Monthly Maintenance of 132/220kV Current Transformer

1340

387

518673.8

... More
Half Yearly Maintenance of 132/220kV Current Transformer

134

581

77867.4

... More
Yearly Maintenance of 132/220kV Current Transformer

89

782

69646.95

... More
Three Yearly Maintenance of 132/220kV Current Transformer

45

937

42190.2

... More
Half Yearly Maintenance of 132/220kV Potential Transformer.

96

387

37158.72

... More
Yearly Maintenance of 132/220kV Potential Transformer

96

782

75124.8

... More
Monthly Maintenance of 120/198 kV Lightning Arrester

696

386

268725.6

... More
Quarterly Maintenance of 120/198 kV Lightning Arrester

232

581

134996.16

... More
Half Yearly Maintenance of 120/198 kV Lightning Arrester

116

782

90775.8

... More
Yearly Maintenance of 120/198 kV Lightning Arrester

116

782

90775.8

... More
Monthly Maintenance of 132/220kV TP Motorized Isolator and Manual Isolator with or without earthing switch

580

387

224842.8

... More
Half Yearly Maintenance of 132/220kV TP Motorized Isolator and manual isolator with or without earthing Switch

58

584

33918.98

... More
Yearly Maintenance of 132/220kV TP Motorized Isolator and manual isolator with or without earthing switch

58

881

51122.36

... More
Monthly Maintenance of 132/220/25 KV DP/SP Motorized Isolator or Manual Isolator with or without earthing switch

1280

585

748800

... More
Half yearly Maintenance of 132/220/25 KV DP/SP Motorized Isolator or Manual Isolator with or without earthing switch

128

980

125478.4

... More
Yearly Maintenance of 132/220/25 KV DP/SP Motorized Isolator or Manual Isolator with or without earthing switch

128

1466

187678.72

... More
Monthly Maintenance of 25 kV Current Transformer (including PFC CT).

920

387

356104.4

... More
Half Yearly Maintenance of 25 kV Current Transformer (including PFC CT).

92

585

53820

... More
Yearly Maintenance of 25 kV Current Transformer (including PFC CT).

61

782

47735.55

... More
Three Yearly Maintenance of 25 kV Current Transformer (including PFC CT).

31

937

29064.36

... More
Quarterly Maintenance of 25 kV Potential Transformer

400

387

154828

... More
Half Yearly Maintenance of 25 kV Potential Transformer.

40

585

23400

... More
Yearly Maintenance of 25 kV Potential Transformer

40

782

31302

... More
Monthly Maintenance of 25 KV DP/SP Circuit Breaker

400

296

118648

... More
Half yearly Maintenance of 25 KV DP/SP Circuit Breaker

40

584

23392.4

... More
Yearly Maintenance of 25 KV DP/SP Circuit Breaker

40

1169

46785.2

... More
Monthly Maintenance of 25 KV DP interrupter

180

296

53391.6

... More
Half yearly Maintenance of 25 KV DP interrupter

18

584

10526.58

... More
Yearly Maintenance of 25 KV DP interrupter

18

1169

21053.34

... More
Monthly Maintenance of 42 KV Lightning Arrester

552

296

163612.8

... More
Quarterly Maintenance of 42 KV Lightning Arrester

184

296

54537.6

... More
Half Yearly Maintenance of 42 kV Lightning Arrester

92

485

44706.48

... More
Yearly Maintenance of 42 kV Lightning Arrester

92

485

44706.48

... More
Quarterly Maintenance of 25kV/240V, 100kVA & 25 KVA LT Auxiliary Transformer

24

296

7118.88

... More
Half Yearly Maintenance of 25kV/240V, 100kVA & 25 KVA LT Auxiliary Transformer

12

584

7017.72

... More
Yearly Maintenance of 25kV/240V, 100kVA & 25 KVA LT Auxiliary Transformer

12

1565

18781.32

... More
Monthly Maintenance of 27.5 KV /0.65 KV, 2.4 MVA Transformer

60

296

17784

... More
Half yearly Maintenance of 27.5 KV /0.65 KV, 2.4 MVA Transformer

6

581

3491.28

... More
yearly Maintenance of 27.5 KV /0.65 KV, 2.4 MVA Transformer

6

1563

9383.4

... More
Quarterly maintenance of 2.2 MVAR CAPACITOR BANK INCLUDING SERIES REACTOR

12

584

7017.72

... More
Half yearly maintenance of 2.2 MVAR CAPACITOR BANK INCLUDING SERIES REACTOR

6

1565

9390.66

... More
Yearly maintenance of 2.2 MVAR CAPACITOR BANK INCLUDING SERIES REACTOR

6

2347

14085.96

... More
Fortnightly battery & battery charger maintenance of TSS

138

387

53415.66

... More
Yearly battery & battery charger maintenance of TSS

6

9382

56293.38

... More
Half Yearly maintenance of Earthing station

108

148

16017.48

... More
Yearly maintenance of Earthing station

108

148

16017.48

... More
Yearly Buried Rail Connection

3

15642

46927.98

... More
Yearly maintenance of Cable Trench Cleaning

3

7817

23451.36

... More
Reclamation of DCP (5kG,10 kG & 25 kG), CO2(9kG) & form type fire extinguisher.

18

59

1065.78

... More
Refilling of DCP (5kG,10 kG & 25 kG), CO2(9kG) & form type fire extinguisher.

18

482

8681.22

... More
Half Yearly Thermal Imaging of Equipment connector.

6

387

2322.42

... More
Monthly Maintenance of 8 MVA Auto Transformer

380

1169

444303.6

... More
Half Yearly Maintenance of 8 MVA Auto Transformer

38

1563

59428.2

... More
Yearly Maintenance of 8 MVA Auto Transformer

38

2445

92921.4

... More
Monthly Maintenance of 25 kV DP Interrupter

360

296

106783.2

... More
Half Yearly Maintenance of 25 kV DP Interrupter

36

584

21053.16

... More
Yearly Maintenance of 25 kV DP Interrupter

36

1169

42106.68

... More
Monthly Maintenance of 25 kV DP Isolator

1220

581

709893.6

... More
Half Yearly Maintenance of 25 kV DP Isolator

122

980

119596.6

... More
Yearly Maintenance of 25 kV DP Isolator

122

1466

178881.28

... More
Quarterly Maintenance of 25 kV Potential Transformer

64

387

24772.48

... More
Half Yearly Maintenance of 25 kV Potential Transformer

32

585

18720

... More
Yearly Maintenance of 25 kV Potential Transformer

32

782

25041.6

... More
Monthly Maintenance of 42 kV Lightning Arrester

1680

296

497952

... More
Quarterly Maintenance of 42 kV Lightning Arrester

280

296

82992

... More
Half Yearly Maintenance of 42 kV Lightning Arrester

140

485

68031.6

... More
Yearly Maintenance of 42 kV Lightning Arrester

140

485

68031.6

... More
Quarterly Maintenance of 25kV/240V, 10kVA LT Auxiliary Transformer

32

296

9491.84

... More
Half Yearly Maintenance of 25kV/240V, 10kVA LT Auxiliary Transformer

16

584

9356.96

... More
Yearly Maintenance of 25kV/240V, 10kVA LT Auxiliary Transformer

16

1565

25041.76

... More
Fortnightly battery & battery charger maintenance

736

387

284883.52

... More
Yearly Maintenance of Battery AND Battery Charger

33

9382

309613.59

... More
Half Yearly maintenance of Earthing station

284

148

42120.04

... More
Yearly maintenance of Earthing station

284

148

42120.04

... More
Yearly maintenance of Cable Trench Cleaning

16

3130

50083.52

... More
Reclamation of DCP (5kG,10 kG & 25 kG), CO2(9kG) & form type fire extinguisher.

32

59

1894.72

... More
Refilling of DCP (5kG,10 kG & 25 kG), CO2(9kG) & form type fire extinguisher.

32

482

15433.28

... More
Yearly Buried Rail Connection

5

15642

78213.3

... More
Half Yearly Thermal Imaging of Equipment connector

32

387

12386.24

... More
Yearly Maintenance of Earth Screen Conductor

16

1466

23459.84

... More
Monthly panel maintenance in TSS

72

2417

174094.56

... More
Monthly panel maintenance in SP/SSP

192

1208

232126.08

... More
Half yearly Cross gantry or any others Gantry Bus Bar maintenance of TSS

12

14001

168015.24

... More
Half yearly Cross gantry or any others Gantry Bus Bar maintenance of SP/SSPs

32

9672

309531.2

... More
Removal and re-erection of PSI Equipment

6

4836

29021.34

... More
Supply & Erection of Caution Board

7

259

1817.06

... More
Provision of Shock Treatment Chart

7

736

5157.32

... More
Supply and erection of 8 SWG GI Wire for earthing

67

32

2147.35

... More
Reinforce concrete for cable trench & cover.

67

1124

75354.23

... More
Supply and repainting of PSI Equipment like Transformer, LA BM, CB, AT as per site requirement with waterproof gray enameled paint by approved brand i.e. Asian Berger etc. as per IS 2932 or latest.

1333

33

44068.98

... More
Supply and repainting of PSI assets i.e. Fencing Panels, Fencing UP right, barbered wire, Tubular pole at TSS/SP/SSP with Aluminum Paint i.e. Asian Berger etc. as per IS 2339 or latest.

2667

30

80516.73

... More
Supply and erection of Earth Pit cover & Box

23

767

17652.96

... More
Removal of Wild vegetation in TSS/SP/SSPs

29333

8

258423.73

... More
Supply and spreading of ballast/Pebbles/Gravels in Switching Stations/TSS yard.

133

1168

155414.49

... More
Supply and erection of earth leads 75 x 8 mm mild steel flat laid in the ground or exposed as per site requirement.

67

220

14756.08

... More
Supply and erection of earth leads 50 x6 mm mild steel flat laid in the ground or exposed as per site requirement.

167

122

20447.48

... More
Manning of TSS

216

6401808

6401808

... More
Breakdown attention of PSI equipment's at TSS/SP/SSPs

90

666

59944.5

... More
Manning of SP/SSP in case of Emergency

67

76313

76313



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.