Dedicated Freight Corridor Corporation Of India Limited Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 10,900Document Cost
₹ 2,000Tender Fee
Refer Documents
Summary
Provision Of Streetlight On Newly Constructed Road Along With Dfccil Track Near Railway Colony Ambala Cantt.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
CGM-DFC-UMB-EL-STREETLGHT-EDFC FIELD UNIT AMBALA-ELECTRICAL/EDFCTender No
CGM-DFC-UMB-EL-STREETLGHTTender Authority
Dedicated Freight Corridor Corporation Of India Limited ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Excavation of cable trench by cutting/breaking station platform concrete/pucca floor digging 400 4 mm deep and then refilling after laying of cable as per IS 1255:1983 or latest version on a cushion of sand 100 mm below and providing protective bricks and soil and ramming, levelling and repairing and finishing the said portion of platform with 1:2:4 cement concrete mixture 100 mm deep from top. Trench width 300 mm wide for laying upto 3 cables with 9 protective bricks per meter.
45
368
16585.65
Earthing with 40 mm dia class 'B' GI pipe 4.5 mtr long as per IS:3043 or latest to achieve earth 5 resistance less than 5 ohm. Masonary enclosure with hinged cover plate of cast iron with locking arrangement (approx. size: 400mm*400mm) on top, provision of earth plate, connection from earth electrode to switch gear/pole as per the site requirement.
5
1212
6060.75
Supply & Recessing/fixing on surface 6 SWG GI wire for loop earthing as site requirement.
50
7
367.5
Supply & erection of 7mtr high hot dip galvanised octagonal pole with top 70mm around face 7 bottom 130 mm thick steel base plate size 200*200*12 mm complete with appropriate sleeve at the top of pole for following mounting arm bracket 300 mm long suitable for LED street light fittings and M20 foundation including casting, muffing with cement concrete foundation (1:2:4) painting, earthing & foundation GI nut bolt with washer and smart pack junction box with single pole MCB and terminals: Single Arm Bracket.
16
11218
179488.64
Supply, erection, testing & Commissiong of LED street light luminaire 90 watt as per CEE/NR/121- Elect/PS/2018 dt 28.6.2018 or latest specification and site requirement. Guarantee 5 years from date of Commissiong. Make of LED light will be ISI marked.
16
4563
73008.32
Supply & fixing of 3-phase & neutral powder painted front side & back open hinged lockable door with gasket distribution box made from 14 SWG CRCA sheet, shall be suitable for 415 V, 50 Hz, supply. Dust & 9 vermin proof with 125 Amp aluminum bus bar, 100 Amp 4 pole AC 415V, thermal & magnetic setting fixed, 10 KA breaking capacity MCCB as main & 4 nos. 63 Amp DP AC 415V, 10KA breaking capacity MCB for circuits. Feeder Post shall be fixed after making concrete foundation as per technical specifications and site requirement. Make of MCCB/MCB will be ISI marked.
2
35490
70980
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements