Dakshin Haryana Bijli Vitran Nigam Limited Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Dakshin Haryana Bijli Vitran Nigam Limited - DHBVN Tender

Works
Eprocure
Opening Date24 Jul 2023
Closing Date11 Mar 2024
Tender Amount₹ 84,58,38,451 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Training for employees (Refer Form -9)

-

-

-

... More
Form-2 : SCADA/DMS Control centre

-

-

-

... More
C1 : Server/Workstation Hardware

-

-

-

... More
SCADA Server

2

-

-

... More
DMS Server

2

-

-

... More
OMS Server

2

-

-

... More
FEP server with interface switches

2

-

-

... More
ISR server

2

-

-

... More
NMS server

2

-

-

... More
DTS server

1

-

-

... More
Other Active Devices(Kindly specify item along with make and model)

1

-

-

... More
Developmental server

1

-

-

... More
Commnuication Server

2

-

-

... More
Web/Directory server(icluding web/network security software)

2

-

-

... More
SMS gaterway

2

-

-

... More
Workstation with dual TFT Monitors ( S/S monitoring)

3

-

-

... More
Workstation with dual TFT Monitors (Network monitoring)

2

-

-

... More
Remote VDUs with one TFT Monitors

29

-

-

... More
Developmental console with one TFT

10

-

-

... More
DTS/Workstation Console with dual TFTs

9

-

-

... More
DLP/ LED based Video Projection system with 3x4 Module configuration with each module at least 70" diagonal with common projector

1

-

-

... More
Storage and backup devices

-

-

-

... More
External RAID Mass storage device ( for 24 months online backup)

2

-

-

... More
Exteranl DAT drive

1

-

-

... More
Switches

-

-

-

... More
Layer II switch (SCADA/DMS LAN)

3

-

-

... More
Layer II switch ( Planning & Development system LAN)

3

-

-

... More
Router

-

-

-

... More
Router for interfacing IT system & SCADA/DMS DR centre

2

-

-

... More
Router at remote VDU

29

-

-

... More
Security System (DMZ)

-

-

-

... More
Web server with load balancing

2

-

-

... More
Mail server

2

-

-

... More
Router

2

-

-

... More
Firewall & network IDS/IPS

2

-

-

... More
Layer II switch

1

-

-

... More
Other Active Devices

-

-

-

... More
GPS Time synchronisation system

2

-

-

... More
Time, day & date digital displays

1

-

-

... More
Printer

-

-

-

... More
Color inkjet printer

4

-

-

... More
B/W Laser printer

2

-

-

... More
Workstation with three TFT Monitors

2

-

-

... More
A3 Multi Function Colour Printer

2

-

-

... More
C2 : Software for Control Center

-

-

-

... More
SCADA software

1

-

-

... More
ISR Software

1

-

-

... More
DMS software

1

-

-

... More
OMS Software

1

-

-

... More
DTS software

1

-

-

... More
Developmental software

1

-

-

... More
Network Management Software

1

-

-

... More
RDBMS package

1

-

-

... More
GIS Adaptor/Engine for importing data from GIS system under IT system

1

-

-

... More
Any other software to meet functional /performance requirement of MTS(Kindly specify item along with make and model)

1

-

-

... More
C3: Mandatory spares Max 5% of C1

-

-

-

... More
Mandatory spares

1

-

-

... More
Form-3 : DR/Control Center

-

-

-

... More
D1 : Server/Workstation Hardware

-

-

-

... More
SCADA Server

1

-

-

... More
DMS Server

1

-

-

... More
OMS Server

1

-

-

... More
FEP server with interface switches

1

-

-

... More
ISR server

1

-

-

... More
NMS server

1

-

-

... More
DTS server

1

-

-

... More
Other Active Devices(Kindly specify item along with make and model)

1

-

-

... More
Developmental server

1

-

-

... More
Commnuication Server

1

-

-

... More
Web/Directory server(icluding web/network security software)

1

-

-

... More
SMS gaterway

1

-

-

... More
Workstation with dual TFT Monitors ( S/S monitoring)

2

-

-

... More
Workstation with dual TFT Monitors (Network monitoring)

2

-

-

... More
Remote VDUs with one TFT Monitors

1

-

-

... More
Developmental console with one TFT

2

-

-

... More
DTS/Workstation Console with dual TFTs

2

-

-

... More
DLP/LED based Video Projection system with 3x4 Module configuration with each module at least 70" diagonal with common projector

1

-

-

... More
Storage and backup devices

-

-

-

... More
External RAID Mass storage device ( for24 months online backup)

1

-

-

... More
Exteranl DAT drive

1

-

-

... More
Switches

-

-

-

... More
Layer II switch (SCADA/DMS LAN)

3

-

-

... More
Layer II switch ( Planning & Development system LAN)

3

-

-

... More
Routers

-

-

-

... More
Router for interfacing IT system & SCADA/DMS DR centre

2

-

-

... More
Router at remote VDU

1

-

-

... More
Security System (DMZ)

-

-

-

... More
Web server with load balancing

1

-

-

... More
Mail server

1

-

-

... More
Router

1

-

-

... More
Firewall & network IDS/IPS

2

-

-

... More
Layer II switch

1

-

-

... More
Other Active Devices

-

-

-

... More
GPS Time synchronisation system

2

-

-

... More
Time, day & date digital displays

1

-

-

... More
Printers

-

-

-

... More
Color inkjet printer

2

-

-

... More
B/W Laser printer

2

-

-

... More
Workstation with three TFT Monitors

2

-

-

... More
A3 Multi Function Clour Printer

2

-

-

... More
D2 : Software for Control Center

-

-

-

... More
SCADA software

1

-

-

... More
ISR Software

1

-

-

... More
DMS software

1

-

-

... More
OMS Software

1

-

-

... More
DTS software

1

-

-

... More
Developmental software

1

-

-

... More
Network Management Software

1

-

-

... More
RDBMS Package

1

-

-

... More
GIS Adaptor/Engine for importing data from GIS system under IT system

1

-

-

... More
Any other software to meet functional /performance requirement of MTS(Kindly specify item along with make and model)

1

-

-

... More
D3 : Mandatory spares Max 5% of D1

-

-

-

... More
Mandatory spares

1

-

-

... More
Form-4 : RTU Equipments

-

-

-

... More
E1 : RTU

-

-

-

... More
RTU base equipment comprising panels, racks, sub-racks, Power Supply modules, CPU, interfacing equipment, required converters & all other required items/accessories including complete wiring for all modules for locations mentioned at Vol Vi

26

-

-

... More
Multifunctions transducers

1430

-

-

... More
Contact Multiplying Relays (CMRs)

13689

-

-

... More
Heavy duty relays for Control

3393

-

-

... More
Dummy Breaker Latching Relays

26

-

-

... More
Transformer Transducers

121

-

-

... More
Single TFT PC for LDMS with 2KVA UPS

26

-

-

... More
Network Switches (24 ports)-IEC- 61850 compliant Ethernet switch with industrial networking capability as per IEEE 802.1 for ethernet redundancy.

50

-

-

... More
Network Switches (48 ports)-IEC- 61850 compliant Ethernet switch with industrial networking capability as per IEEE 802.1 for ethernet redundancy.

2

-

-

... More
L2 Industrial Grade Managed Switch with 8 X SFP slots (1000Mbits/sec) and 4 X (100 Mbits/sec) Twisted Pair (TX)/RJ45 along with supply of necessary patch chords and adaptors

10

-

-

... More
L2 Industrial Grade Managed Switch with 12 X SFP slots (1000Mbits/sec) and 4 X (100 Mbits/sec) Twisted Pair (TX)/RJ45 along with supply of necessary patch chords and adaptors

10

-

-

... More
L3 Industrial Grade Managed Switch with 48 X SFP slots (1000Mbits/sec) and8 X (100 Mbits/sec) Twisted Pair (TX)/RJ45 along with supply of necessary patch chords and adaptors

10

-

-

... More
Fibre Optic Distribution Panel with 12 ports along with supply of necessary patch chords and adaptors

10

-

-

... More
Fibre Optic Distribution Panel with 16 ports along with supply of necessary patch chords and adaptors

10

-

-

... More
Fibre Optic Distribution Panel with 20 ports along with supply of necessary patch chords and adaptors

10

-

-

... More
Fibre Optic Distribution Panel with 24 ports along with supply of necessary patch chords and adaptors

10

-

-

... More
Fibre Optic Distribution Panel with 96 ports along with supply of necessary patch chords and adaptors

10

-

-

... More
E2 : Software for LDMS

-

-

-

... More
LDMS software

26

-

-

... More
E3 : Test Euipment for RTU

-

-

-

... More
RTU Database Configuration & Maintenance Software tool

2

-

-

... More
Master Station cum RTU Simulator & Protocol analyser software tool

2

-

-

... More
Laptop PC for above software tools along with interfacing hardware including Hub

2

-

-

... More
E4 : Mandatory spares Max 5% of E1

-

-

-

... More
Mandatory spares

1

-

-

... More
Form-5 : FRTU Equipments

-

-

-

... More
F1 : FRTUs

-

-

-

... More
Mini pole mounted FRTU base equipment along with enclosure suitable to work in open environment (Adequate protection from water & dust) , racks, sub-racks, Power Supply modules with power backup , I/o modules, CPU, interfacing equipment, required converters & all other required items/accessories including complete wiring for all modules for locations mentioned at Vol Vi

3056

-

-

... More
Contact Multiplying Relays (CMRs)

5

-

-

... More
Heavy duty relays for Control

5

-

-

... More
Multifunction trnasducer

2

-

-

... More
Any other software to meet functional /performance requirement of MTS(Kindly specify item along with make and model)

1

-

-

... More
Network Switches (12 Ports)

3056

-

-

... More
F2 : Test Euipment for FRTU

-

-

-

... More
FRTU Database Configuration & Maintenance Software tool

5

-

-

... More
Master Station cum FRTU Simulator & Protocol analyser software tool

5

-

-

... More
Laptop PC for above software tools along with interfacing hardware including Hub

5

-

-

... More
F3 : Mandatory spares Max 5% of F1

-

-

-

... More
Mandatory spares

1

-

-

... More
Form-6 : Communication System

-

-

-

... More
G1 : MPLS

-

-

-

... More
Annual charges for 100MBps Links for MCC & DR Center

4

-

-

... More
Annual charges for 8MBps Links for substation & Remote VDU

55

-

-

... More
MPLS Router

59

-

-

... More
G2 : Mandatory spares Max 5% of G1

-

-

-

... More
Mandatory spares

1

-

-

... More
Form-7 : Power Supply

-

-

-

... More
H1 : Main Equipments - Control centre

-

-

-

... More
UPS with suitable rating running in parallel redundant mode*(Including VRLA type Battery banks for above UPS for minimum 30 min. backup duration)

1

-

-

... More
H2 : Main Equipments - DR centre

-

-

-

... More
UPS with suitable rating running in parallel redundant mode*(Including VRLA type Battery banks for above UPS for minimum 30 min. backup duration)

1

-

-

... More
H3 : For RTU / Data Concentrator / Communication Eqpts.

-

-

-

... More
DC Power Supply (DCPS) system based on SMPS (including Battery bank for above DCPS (VRLA Type) for minimum 4 hrs backup )

26

-

-

... More
H4 : For RTU / Data Concentrator / Communication Eqpts.

-

-

-

... More
UPS (2 kVA )

30

-

-

... More
H5 : Mandatory Spares for UPS

-

-

-

... More
5% of above H1 to H4

1

-

-

... More
Form-8 : SCADA Enablers

-

-

-

... More
J1 : Control/power cable for RTUs from outdoor switchgear,if any at S/S and numerical relays

-

-

-

... More
Control Cable armoured (1 sq mm for Control and Monitoring element wiring) (as required) with miscellaneous consumables items for e.g. connectors, thimbles etc (30 mtr per DSS)

2.5

-

-

... More
Control Cable armoured (2.5 sq mm for CT & PT wiring) (as required) with miscellaneous consumables items for e.g. connectors, thimbles etc (30 mtr per DSS)

2.5

-

-

... More
Serial Communication Cable (2 Pair laid in armoured steel Conduit) to Integrate existing Relay or Meter or FPI (20 mtr per RMU).

2.5

-

-

... More
Ethernet CAT6 Cable in steel Conduit to Integrate existing Relay, Meter or WAN Router connectivity (20 mtr per RMU) with miscellaneous consumables items like RJ 45 connectors & Patch Code

2.5

-

-

... More
Numerical relay /BCPU- IEC-61850 Compiant

574

-

-

... More
IEC 61850 compliant Relays for 66Kv panels as per technical specifications

108

-

-

... More
J2 : Mandatory spares Max 5% of J1

-

-

-

... More
Mandatory Spares

1

-

-

... More
Form-9 : Training for employees

-

-

-

... More
Operator for SCADA/DMS Control Centre

5

-

-

... More
Instructor for DTS

10

-

-

... More
Computer Hardware & System Software

10

-

-

... More
Application Software (SCADA/DMS)

10

-

-

... More
RTU & FRTU

5

-

-

... More
Database & display development

5

-

-

... More
Auxiliary Power Supply

3

-

-

... More
Communication System including NMS

5

-

-

... More
Form -10 : FMS

-

-

-

... More
FMS charges for SCADA/DMS system (maintaining overall system availability as per TS)(per year)

-

-

-

... More
FMS/Year

1

-

-

... More
FMS for 2 years

2

-

-

... More
FMS for 5 years (add. 3 years)

5

-

-

... More
FMS charges for SCADA/DMS system (maintaining availability individual hardware & non –critical functions as per TS)

-

-

-

... More
FMS/Year

1

-

-

... More
FMS for 2 years

2

-

-

... More
FMS for 5 years (add. 3 years)

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.