Command Area Development Authority Tender
... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 61,419Document Cost
₹ 2,500Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_HBC_439788_1Bid Award Id
ViewTender No
2025356A1BC6 E933 4BE3 BC0B B120F967B4FA1841CADTender Authority
Command Area Development Authority ViewPurchaser Address
-Website
http://etenders.hry.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Providing and fixing 12 Watt LED Street Lighting of 75 watt solar panel, 12.8 volt 30 Ah Lithium Ferro Phosphate battery, 12 Watt White LED Luminaire and Pole of 5 Meter above ground level with dusk to dawn operation {first 4 hours full light Systemding, fixing and testing of Solar light including battery: min. 24 lux) , rest of the time at lower light (50% Min. 12 lux) level} and 3 days or minimum 36 operating hours autonomy or as per direction of engineer-in-charge (As per rates approved by HAREDA) (NS)
4
-
-
... More
Hydrant assembly for Nakka in field, Rates including Tee, riser pipe, butterfly valve, Flange and labour for fixing butter fly valve should be as per IS 13095-2020 (NS)
21
-
-
... More
Providing, fixing,testing and commissioning of pressure gauge 2` dial with Glycerin filled to be fixed before and after filtration unit ( Rates approved in TAC,MICADA Haryana meeting on 09.02.2022)(NS)
4
-
-
... More
Providing, fixing, testing of 110 mm HDPE pipe (for jointing floater, all filters, PRV etc) PE 80 (Brand Name-Suprem, Ashirwad, Finolex, Jain Irrigation, Astral Pipe, Prince Pipe, Nimbus) (NS)
40
-
-
... More
Providing fixing of Header Assembly/Manifold 3`(loose) Rates approved vide memo No.MICADA/2021/3068-70 dated 07.06.2021 (NS)
2
-
-
... More
Construction of 8`x8` control room constructed with 9` thick brick masonary inner side covered with 6` thick RCC slab in 1:1.5:3 concrete slab of size 9.5`x12` mix with proper door and 2 No windows and electric installation as per approved design and drawing inner size 8`x8` and Height 9` from DPC level complete in all respect (NS)
1
-
-
... More
Providing and lowering of HDPE floater manufactured with 225 mm dia PE pipe having PE-80 and PN-10 to float the submersible open well pump/motor (NS)
2
-
-
... More
Supply Installation testing commissioning of Solar Photovoltaic Stand alone Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength. Including lightning and surge voltage protection, Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required, built in metering system to moniter plant performence (Amp-meter, Volt-meter, Frequency meter, Energy meter, Watt-meter, and other instrument/equipment as required) Note:- PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Mono Crystalline Silicon Solar Cell Modules IEC 61215/IS14286. In addition, the modules must conform to IEC 61730 Part-1- requirements for construction and Part 2 – requirements for testing, for safety qualification or quivalent IS and be mounted on fixed Aluminium/GI structure of adequate strength and design as per IEC/IS specification. Including field-based electroluminescence (EL) study be performed after receiving the modules at site and after installation. Module mounting structure (MMS) design and drawing shall be duly vetted from government institute Including third party inspection Actual parameters/capacity will be finalized after approval of design and drawing. ( Rates approved in TAC,MICADA Haryana meeting on 09.02.2022)` (NS)
16.5
-
-
... More
Supplying,erection,testing and commissioning of Solar AC Open-well Submersible Pump Set with power capacity 7.50 HP three phase motor having casing of Alloy Steel for the required power capacity,discharge and Head including all PVC insulated polymer sheathed 3 core flat type cabling in conduit,required from solar plant to solar pump through control room.(Rates approved vide 6th TAC Meeting) (NS)
2
-
-
... More
Supplying, erection, testing and commissioning of Variable Frequency Drive (VFD) complete with all accessories for 7.50 HP power capacity of Solar Pump (Rates approved vide 6th TAC Meeting) (NS)
2
-
-
... More
Providing, lowering, laying, aligning, fixing in position and jointing ( with medium bodied cement solvent) at all level/depths of type-B, Class-2 (4kg/cm2) UPVC pipes for water supplies as per IS code 4985-2021 (amended up to date) in trenches in complete including cost of specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing ) and commissioning as per technical specifications and as per direction of engineer. Rate includes cost of all specials like bends, tees required during laying of pipe line along required Alignment . 110 mm upvc Pipes (NS)
2718
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements