If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 41,350Document Cost
₹ 1,000Tender Fee
₹ 1,180
Summary
Installation Of Solar Power Pressurized Irrigation Infrastructure At Overflowing Sadak Vali Pond In Village Bhanguri With Pond Id 01hrpwlhtn0228bhan001, Block Hathin (aspirational Block) Distt. Palwal
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HBC_403047_1Bid Award Id
ViewTender No
202457FFCF41 38A1 43B8 973E 9EC32A37D8751959CADTender Authority
Command Area Development Authority ViewPurchaser Address
-Website
http://etenders.hry.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Providing and fixing of AC Submersible pump set with three phase 50Hz ±3% rated motor frequency, 415V ± 3% rated motor voltage, (Submersible motors shall conform to all the requirements of IS 9283) Solar A.C. Agricultural Pumps alongwith Universal Solar Pump Controller (USPC). All external part of motor used in open well submersible pump having casing of Alloy steel confirming to IS 3444 As per IS code 14220-2018 including third party inspection.Average discharge 13 LPS / Head 52 meter / minimum / minimum output rating of 15 KW duly installed on the suitable foundation. Actual pump set`s parameters will be finalized after approval of design and drawing. Solar Pumping Sets should be of the make: KSB / Shakti/ Kirloskar /CRI/Lubi/ Crompton/ WPIL (AC Submersible pump set 10 HP
1
-
-
Supplying, erection, testing and commissioning of Variable Frequency Drive (VFD) complete with all accessories for the required power capacity of Solar Pump ,VFD Drive for Pump set of power capacity 10 HP
1
-
-
Horizontal directional drilling with micro tunnelling methods, for pipe laying under pucca rasta /road crossing (N.S.Item)
25
-
-
Providing and lowering of HDPE floater to float the submersible open well pump/motor (NS item)
1
-
-
Supply Installation testing commissioning of Solar Photovoltaic Stand alone Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength, anti-theft screws. Including lightning and surge voltage protection, Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required, built in metering system to monitor plant performance (Amp-meter, Volt-meter, Frequency meter, Energy meter, Wattmeter, and other instrument/equipment as required) Note:- PV modules used must qualify to the latest edition of IEC PVmodule qualification test or equivalent BIS standards Mono Crystalline Silicon Solar Cell Modules IEC 61215/IS14286. In addition, the modules must conform to IEC 61730 Part-1- requirements for construction and Part 2 – requirements for testing, for safety qualification or equivalent IS and be mounted on fixed Aluminium/GI structure of adequate strength and design as per IEC/IS specification. Including field-based electroluminescence (EL) study be performed after receiving the modules at site and after installation. Module mounting structure (MMS) including suitable foundation, design and drawing shall be duly vetted from government institute Including third party inspection.
11
-
-
Providing and fixing 12 Watt LED Street Lighting of 75 watt solar panel, 12.8 volt 30 Ah Lithium Ferro Phosphate battery, 12 Watt White LED Luminaire and Pole of 5 Meter above ground level with dusk to dawn operation {first 4 hours full light Systemding, fixing and testing of Solar light including battery: min. 24 lux) , rest of the time at lower light (50% Min. 12 lux) level} and 3 days or minimum 36 operating hours autonomy or as per direction of engineer-in-charge
3
-
-
Providing, fixing, testing and commissioning of pressure gauge 2” dial with Glycerin filled (NS Item)
2
-
-
Complete operation and Maintenance and watch and ward of the project for one year including operation of pump, pipe line, accessories, electromechanical, solar plants complet in all respect of pump house, pipe line and accessories, electromechanical, solar plant etc complete in all respect for one year
12
-
-
Construction of 6`x6` regulation hut constructed with 9` thick brick masonary inner side covered with 1.25 mm thick class-1 GI corrugated sheets (with 750 gm Zinc coating per sqm on its both sides) provided with proper door and windows as per approved design and drawing inner size 6`x6` Av. Height 8` covered with Precoated G.I. Corrugated sheet ( Non Scheduled item )
1
-
-
Hydrant assembly for Nakka in field, Rates including Tee, riser pipe, butterfly valve, Flange and labour for fixing butter fly valve should be as per IS 13095-2020 (Rates are as per analysis including HSR item 25.3.6)
11
-
-
Providing, lowering, laying, aligning, fixing in position and jointing (with medium bodied cement solvent) at all level/ depths of TypeB, Class-2 (4 Kg/cm2)UPVC pipes for water supplies as per IS code 4985 : 2021 (amended up to date) in trenches in complete including cost of Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per directionof Engineer. Rate includes cost of all specials like bends , tees required during laying of pipe line along required alignment. UPvc Pipe 140 mm dia.
392
-
-
Providing, lowering, laying, aligning, fixing in position and jointing (with medium bodied cement solvent) at all level/ depths of TypeB, Class-2 (4 Kg/cm2)UPVC pipes for water supplies as per IS code 4985 : 2021 (amended up to date) in trenches in complete including cost of Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per directionof Engineer. Rate includes cost of all specials like bends , tees required during laying of pipe line along required alignment. UPvc Pipe 110 mm dia.
1089
-
-
Providing and fixing Tank Type (Make of Metal) Fertilizer and Chemical Injector System confirming to IS 14483 (Part 3) of 2018 for demonstration and guiding the farmers regarding fertilization and chemicalisation of system. (rates include ventury with manifold 1.0`=1300 and 60 liter fertilizer tank= 4400 ) rate approved by worthy Administrator
1
-
-