Chaudhary Ranbir Singh University Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 1,20,000Document Cost
₹ 5,900Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_HRY_142367_1Bid Award Id
ViewTender No
Smart Entrance System with Body Temperature and MaTender Authority
Chaudhary Ranbir Singh University ViewPurchaser Address
-Website
http://https://haryana.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply, installation, testing and commissioning of Boombarrier with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work. MAKE : HYUNDAI/ZKTECO/CAMEY/MAGNETIC/TEKWIN
Boom Type Telescopic Boom
Boom Length 6m
Opening/Closing Time 6s
Supply Voltage 110V AC or 220V AC
Frequency 50-60Hz
Cabinet Material Powder Coated Steel
Boom Material Aluminium alloy
Working temperature Range -20℃~+60℃
Working humidity 90%
2
-
-
Supply installation testing and commissioning of Access Control Pannel with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.MAKE : HYUNDAI/ZKTECO/CAMEY/MAGNETIC/TEKWIN
Number of doors Controller 2
Numbers of readers supported 4
Type of readers Supported 26-bit Wiegand and RS485
Numeber of inputs 6
Number of Outputs 4
Cards holder capacity 30000
Fingerprint Capacity 3000
Log Event Capacity 100000
Communication TCP/IP,RD-485 and WIFI Optional
CPU 32bit 400MHz CPU
Ram 32M
Flash memory 128M
Operating Temperature 0-45 °C
Operating Humidity 20% to 80%
1
-
-
Supply Installation testing & commissioning of Handheld thermal camera along with tripod including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical
specification : MAKE : HYUNDAI/VIRDI/ZKteco/SOMFY/TEKWIN
THERMOGRAPHIC IR Resolution 256*192 Pixel pitch 12µm NETD 50mK Lens 3.2mm FOV 56° * 42.2° IFOV 3.8mrad
THERMOGRAPHY Measuring Tools Center Spot/Hot Spot/Cold Spot Measuring range 30°C ~ 45°C Measuring Accuracy ±0.5°C Temperature unit °C,°F,K MRTD 0.1°C Emissivity Correction 0.01~1.0 Adjustable Illumination LED lights Image Mode Thermal,Thermal Fusion,PIP Palette White Hot,Black Hot,Iron, Lava,Rainbow,rainbow HC,
Black red Temperature Alarm Full Frame Max. Temperature & Min Temperature
Alaram Snapshot Snapshot with Temperature data Save Snapshot manual/Auto PC Analysis Software Support Display 2.8 LCD SD Card 16GB Micro SD Card Supported Battery type Rechargeable Li- battery Power Interface USB direct Charge type C Charging Time About 4H Battery Life ≥11H Auto Power Off Adjustable (5 Min, 10 Min,20 min)
OTHERS Tripod Supported Operating
temperature 10°C ~ 50°C Humidity 10% 95%, Non Condensing Enclosure Protection IP54 2m Drop
1
-
-
Supply, installation, testing and commissioning UHF Tags Frequency :- 860~960MHz , Reading Distance:- Up to 10 meters for UHF1-10E and UHF1-10F (Determined by the environment and reader), Protocol type:- ISO/IEC 18000-6C, EPC global Class 1 Gen 2, Working mode:- Passive (No battery), Storage Strucuture:- EPC: 96bits, UID/TID: 64bits, User: 512bits Kill Password: 32bits, Access Password: 32bits , Erase Endurance:- 100,000times, Data Storage Period:- 10years , Working Temperature:-0~60°C , Curvature:-
60mm with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work. MAKE : HYUNDAI/ZKTECO/CAMEY/MAGNETIC/TEKWIN
100
-
-
Supply Installation testing & commissioning of Device self Mount Stand for terminal device including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. : MAKE : HYUNDAI/VIRDI/ZKteco/SOMFY
2
-
-
Supply Installation testing & commissioning of Trunstile Stand for terminal Device including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specification : MAKE :
HYUNDAI/VIRDI/ZKteco/SOMFY/TEKWIN
4
-
-
Supply Installation testing & commissioning of 12-core SingleMode OFC including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (MAKE : MOLEX/DLINK/BELKIN/VPRO)
1000
-
-
Supply Installation testing & commissioning of Cat 6 Cable including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (MAKE : MOLEX/DLINK/BELKIN/VPRO)
305
-
-
Supply Installation testing & commissioning of Cat 6 Armoured Cable including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (MAKE : MOLEX/DLINK/BELKIN/VPRO)
305
-
-
S/E of PVC insulated multi core copper conductor cable (unarmoured) 1100 volts grade (round) in existing pole/ pipe, complete in all respect including making necessary connections.
i) Size2.50 Sqmm x 3 core (Finolex/RR Kabel/Havells/VPRO)
100
-
-
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall/ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of
work.
(b) 25 mm dia on surface
150
-
-
S/E of Plain HDPE pipe for optical fibre cable as per IS 4984-1995 laid 1 mtr. below ground level including diging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe, complete in all respect upto the entire satisfaction of Engineer- incharge of the work.
(i) HDPE pipe 50 mm outer dia. (ISI)
1000
-
-
Digging of trench for HDPE pipe and fibre optic cable, 4 mtr below ground level with trenchless Horizontal directional drilling machine pipe pulling (HDD) machine complete in all respect.
1000
-
-
Supply Installation testing & commissioning of Black, 12F, 1U, Loaded with, Splice tray, Couplers & Pigtails including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge (MAKE : MOLEX/DLINK/BELKIN/VPRO)
5
-
-
Supply installation testing and commissioning of SC-LC Fibre Patch Cord with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work. (MAKE : MOLEX/DLINK/BELKIN/VPRO)
20
-
-
Supply installation testing and commissioning of 1-port mini-GBIC LX Single-mode Fiber Transceiver (up to 10km, support 3.3V power) with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.(MAKE : CISCO/DLINK/RUCKUS)
10
-
-
Supply installation testing and commissioning of 8-Port PoE Switch Layer 2 - Rack Mountable PoE Gigabit Ethernet standalone chassis, provides 8 RJ-45 10/100/1000 BaseT, 2 SFP/RJ-45 10/100/1000 BaseT or 100/1000 BaseX combo with AC power supply, option for stacking module, with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work. (MAKE : CISCO/ALCATEL/RUCKUS/DLINK)
5
-
-
Supply Installation testing & commissioning of outdoor 12*12 box for PTZ including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. It Should be dust and water proof.(MAKE : STRONGER/SYNTEX/VPRO)
5
-
-
Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. As per HSR 31.17 (CP@30%)SPN MCB of 9 KA breaking capacity 6 amp. to 32 amp.
10
-
-
Supply, Installation, testing & commissioning of 6U wall mount rack 400mm deep with front door glass consisting of power distribution 5 amp., mounting hardware, cable manager with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.(MAKE
:DLINK/DYNAMIC/VPRO/SUNSHINE)
5
-
-
Supply installation testing and commissioning of Workstation Core i-7,8GB Ram with Graphic card which can encode camera with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work. (MAKE : DELL/HP/LENOVO)
1
-
-
Supply & erection of 25mm Pvc HDPE Flexible pipe including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge.
50
-
-
Supply Installation testing & commissioning of RJ45 Connector including cost of petty material required to complete the work up to the entire satisfaction of Engineer In Charge. (MAKE : DLINK/AMP/WBOX)
50
-
-
Supply installation testing and commissioning of 1000VA UPS It should High end Micro Controller based, Wide Input voltage range, Short circuit and Overload Protection, Over Temperature Protection, Output Frequency fixed at 50Hz or can be synchronized with Input Frequency, Static Bypass Enable or Disable, Protection from DC Fan failure, 14 AH Battery Capacity, Power Backup 45Min with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.(MAKE : NUMERIC/APC/EMERSON)
5
-
-
Supply, Installation , testing & commissioning of Software for integration of Smart Terminal along with temperature detection & Time attendance software with customisation on one plateform for whole system complete in all respect.
1
-
-
Supply Installation testing & commissioning of 32 inch Smart TV including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical
specification : MAKE : HYUNDAI/SAMSUNG/LG/PANASONIC
1
-
-
Supply Installation testing & commissioning of LPR CAMERA to capture the Number Plate including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specification : MAKE : HYUNDAI/TEKWIN/DAHUA/ZKTeko
1
-
-
Supply Installation testing & commissioning of workstation ,Core i-3 PC including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specification : MAKE : DELL/LENOVO/HP
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements