Chaudhary Ranbir Singh University Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 24,000Document Cost
₹ 5,000Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_HRY_422918_1Tender No
Chemistry EquipmentsTender Authority
Chaudhary Ranbir Singh University ViewPurchaser Address
-Website
http://https://haryana.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Hot air oven
The inner chamber should be made of stainless steel and the outer chamber should be M.S powder Coated. The maximum capacity of the oven should be 100 mL or more. The operational temperature should be between ambient to 250 oC or more with a temperature accuracy of ±1o C. PID based digital Temperature control.
2
-
-
... More
Double distillation unit
The unit should be pyrogen free with a distillation water output capacity of 1.5 L/h. The minimum cooling water requirement should be 1lt/min. Auto-power cut facility in case of halted supply of water.
1
-
-
... More
Circulating oil bath
The oil bath should be made up of stainless steel with 4 digit 7 segment LED display for temperature and time. The bath should have S.S perforated tray for holding flasks. The bath should have a capacity to accommodate flask of 1L. The working temperature range should be +5 to 240 oC (0.1 oC increment) with a temperature stability of ±1oC.
1
-
-
... More
Water bath
The water bath should have a capacity of 20 L within built water level sensor. The bath should be made up of stainless steel and supplied with 8 concentric rings. The bath should have digital temperature control with PT100 sensor. The system should have stirring capability with PTFE magnetic bars.
2
-
-
... More
pH conductivity meter Operational between a pH range of -2 to 16.00 with a resolution of 0.01 pH and an accuracy of 0.02 pH. 5 points calibration. The EC range should be in between 0.00 to 29.99 μS/cm
1
-
-
... More
UV cabinet Operational at two UV wavelengths (254 and 365 nm). The cabinet should also be equipped with one visible light. The external body should be coated with MS powder/epoxy.
1
-
-
... More
Flame Photometer
Application: The flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flame
temperature. These metals include Na+, K+, Ca2+, Ba2+ and Li2+.
Specification Requirement
Measuring Range Na+: 0 to 99.9 ppm K+:0 to 99.9 ppm Ca2+ :0-99.9 ppm
Li2+: 0 to 99.99 ppm
Sensitivity Na+= 0.1 ppm
K+ = 0.1 ppm
Specificity Less than 0.5% interference when concentrations are equal to test sample concentrations
Gas Control-Adjustable with knobs
Ignition System-Auto Ignition System
Flame Failure-Auto detection
Gas Cut off-Automatic
Reproducibility-Less than 1% coefficient of variation for 20 consecutive samples
using 10 ppm Na set as maximum standard
Linearity-Less than 1%
Display LED, 12.5 mm (1/2")
Fuel supply-High-grade propane/butane mixture regulated at approximately
30 psi
Air supply-6 L/min at 12 psi; oil and moisture free
Recorder-output 0.05 to 5 V (switchable)
Operating manuals, service manuals, other manuals Should provide
• User, technical and maintenance manuals in English language
• List of equipment and procedures required for local calibration and routine maintenance
• Service and operation manuals to be provided advanced maintenance tasks documentation, if any.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%