If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Chaudhary Charan Singh Haryana Agricultural University Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date26 Aug 2022
Closing Date14 Sep 2022
Tender Amount₹ 1,54,00,000 
Notes
Download

Costs

  • EMD

    ₹ 3,08,000
  • Document Cost

    ₹ 15,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. (HSR 5.14)

939.4

-

-

... More
Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. (HSR 5.26)

7.76

-

-

... More
Dismantling cement conglomerate / terrazzo floors 25 mm to 50 sqm mm manually/ by mechanical means and disposal of material within standard lead as per direction of Engineer- in-charge. (HSR 5.42)

939.4

-

-

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 1 O mm to 25 mm (HSR 5.43.1)

80.26

-

-

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead). (HSR 5.45)

199

-

-

... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (HSR 5.70)

66.5

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)

35.25

-

-

... More
Making plinth protection 50mm thick of cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (HSR 6.13)

167.22

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: (HSR 6.14.1) 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size)

2.55

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size) (HSR 6.15.1)

4.9

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.16)

11.35

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete (HSR 6.30.1)

10.4

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies (HSR 6.30.3)

29.25

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ) (HSR 6.30.4)

90.3

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers (HSR 6.30.5)

14

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts (HSR 6.30.6)

15.6

-

-

... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc.complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more (HSR 6.34.6)

2131

-

-

... More
Brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.20.1)

23.7

-

-

... More
Brick work with common burnt clay non-modular bricks of class designation 10 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.22.2)

8.3

-

-

... More
Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. Cement mortar 1 :4 ( 1 cement :4 coarse sand) (HSR 7 .28.2)

53.4

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab over 0.50 sqm (HSR 8.26.2.2)

102.5

-

-

... More
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: With common burnt clay non-modular brick tile of class designation 10 (Based on HSR 9.11.1) Note:- Excluding the element of mud and brick tiles:- Mud and brick tiles of recovered from demonisation shall be supplied free of cost to agency for re-used.

939.4

-

-

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing periMeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and30 mm long, the periMeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of periMeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charae but excludina the cost of painting with 12.5 mm thick tapered edge gypsum moisture resistant board (HSR 9.46.3)

183.4

-

-

... More
Providing and Fixing 15 mm thick densifled tegular edged eco friendly light weight calcium silicate false celling tiles of approved texlure of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm interval and laying 15 mm thick densifled edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixlures, smoke detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ·r, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. (HSR 9.48) Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, noncombustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/mK.

428

-

-

... More
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diaMeter (HSR 9.57.2)

54.86

-

-

... More
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)

6.68

-

-

... More
Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1 :4 (1 cement: 4 coarse sand). Light shade pigment using white cement (HSR 10.30.1)

8.36

-

-

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 :4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, sqm Cat Eye or equivalent. (HSR 10.50.1 )

2.78

-

-

... More
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.58)

80.26

-

-

... More
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1 :4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (HSR 10.60)

39.58

-

-

... More
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.62)

53.5

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (HSR 10.63.2)

611

-

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (HSR 10.67.2)

46.25

-

-

... More
Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm (HSR 10.70.2)

658

-

-

... More
Cement Concrete 1 :8:16 Flooring Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. (HSR 10.100.2)

1

-

-

... More
12 mm cement plaster of mix : 1 :4 (1 cement: 4 fine sand) (HSR 11.5.3)

344

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1 :4 (1 cement: 4 fine sand) (HSR 11.6.1)

343.65

-

-

... More
12 mm cement plaster finished with a floating coat of neat cement of mix : 1 :4 (1 cement: 4 fine sand) (HSR 11.11.2)

3.34

-

-

... More
Pointing on brick work or brick flooring with cement mortar 1 :3 (1 cement : 3 fine sand): Flush / Ruled/ Struck or weathered pointing (HSR 11.25.1)

1173

-

-

... More
Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete (HSR 11.58)

3134

-

-

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer (HSR 11.64.1)

3134

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer (HSR 11.67.1)

3134

-

-

... More
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 11.76)

105.2

-

-

... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)

105.2

-

-

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)

105.2

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 litre/1 O sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (HSR 11.95.1)

1173

-

-

... More
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws (HSR 12.37.1)

44

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (HSR 12.157.1.1)

522

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (HSR 12.157.2.1)

350

-

-

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides (HSR 12.158.2 )

38

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (HSR 12.159.2 )

43

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). (HSR 12.171)

43.79

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (HSR 13.41)

99

-

-

... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (HSR 30.21)

687.3

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work (HSR 30.28.1)

235.45

-

-

... More
Providing and fixing 15 mm to 18 mm thick Sarderali Granite stone (polished) in flooring including matching grains laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete in all respect. (NS)

328

-

-

... More
Providing and fixing 15 mm to 18 mm thick Sarderali Granite stone (polished) in skirting including matching grains laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete in all respect. (NS)

19.5

-

-

... More
Providing and fixing 100 mm wide vertical Venetian blinds of required size and shape (Vista make select range), fixed in position including rawl plugs and screws, etc., complete in all respects as per drawing and design. (NS)

108

-

-

... More
Collection of common burnt clay non-modular brick tile of class designation-10 at site of work including carriage, loading, unloading and stacking etc., complete in all respect. (NS)

22536

-

-

... More
Scraping of brick tiles of size 22.86cm x 11.43cm x 3.81cm in cement mortar, complete in all respect as directed by Engineer-In-charge. (NS)

15030

-

-

... More
Public health work 64 to 113:- Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. All kinds of soil (HSR 4.12.1)

178.44

-

-

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc. exceeding 300 mm metre (HSR 4.16.1.3)

338.06

-

-

... More
Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.21.1)

58.53

-

-

... More
Providing and laying of conglomerate floor 40mm thick cement concrete topping 1 :2:4 (HSR 10.8)

4.73

-

-

... More
Cement Concrete 1 :8:16 Flooring Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. (HSR 10.100.2)

40.5

-

-

... More
12 mm cement plaster of mix : 1 :3 (1 cement: 3 fine sand) (HSR 11.5.2)

28.42

-

-

... More
1 :4 (1 cement: 4 fine sand) (HSR 11.5.3)

127

-

-

... More
Stringing out A.C./P.V.C pipes and specials casting along trenches and laying the same in trenches, to correct alignment and gradients including cartage from divisional stores or nearest railway station to site of works and return of pieces of pipes to stores. 100 mm internal diameter of pipe line laid complete (HSR 20.7.3)

77.72

-

-

... More
150 mm internal diameter of pipe line laid complete (HSR 20.7.5)

128

-

-

... More
200 mm internal diameter of pipe line laid complete (HSR 20.7.6)

115

-

-

... More
250 mm internal diameter of pipe line laid complete (HSR 20.7.8)

223

-

-

... More
Jointing A.C./P.V.C. pipes and specials with cast iron detachable joints/split coupler P.V.C. joints fitted with bolts and nuts excluding cost of detachable joints/ split coupler P.V.C. joints rubber rings, bolts and nuts but including cost of labour and tools etc. and tested complete 100 mm i/d pipe (HSR 20.8.3)

13

-

-

... More
150 mm i/d pipe (HSR 20.8.5)

20

-

-

... More
200 mm i/d pipe (HSR 20.8.6)

19

-

-

... More
250 mm i/d pipe (HSR 20.8.7)

36

-

-

... More
Cutting A.C./P.V.C. pipes and specials and chipping or filing surface to a uniform finish 100 mm i/dia (HSR 20.9.3)

4

-

-

... More
150 mm i/dia (HSR 20.9.5)

5

-

-

... More
200 mm i/dia (HSR 20.9.6)

6

-

-

... More
250 mm i/dia (HSR 20.9.7)

8

-

-

... More
Providing and fixing white vitreous chinaware laboratory sink including making all connections excluding cost of fittings : Size 600x450x200 mm (HSR 22.7.2)

20

-

-

... More
Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). One way (HSR 22.8.1)

5

-

-

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia (HSR 22.14.2.1)

20

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (HSR 22.22.1)

2

-

-

... More
Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required. Single half stall urinal with 5 litre P.V.C. automatic flushing cistern (HSR 22.26.1)

3

-

-

... More
Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required. Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern (HSR 22.26.4)

1

-

-

... More
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White (HSR 22.39.1)

4

-

-

... More
Providing and fixing partitions for different type of urinals. Vitreous Chinaware Partition plate Large size 835mm x 355 mm White (HSR 22.50.1.2.1)

6

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes (HSR 22.86.2)

365.96

-

-

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore (HSR 22.104.1)

13

-

-

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore (HSR 22.106.1)

34

-

-

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore (HSR 22.107.1)

10

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore (HSR 22.108.1)

10

-

-

... More
Providing M.S. foot rests including fixing in manholes with 20 x 20 x10 cm cement concrete blocks 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20 mm diameter round bar (HSR 22.198.2)

18

-

-

... More
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (HSR 22.209)

5

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, up to 90 metre depth below ground level. All types of soil 300 mm dia (HSR 33.6.1.1)

270

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, Unplasticised PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia (HSR 33.8.2)

256.62

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia (HSR 33.9.2)

48

-

-

... More
Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. (HSR 33.12)

25.83

-

-

... More
Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (HSR 33.13)

25.83

-

-

... More
Supplying, filling, spreading & levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. (HSR 33.14)

25.83

-

-

... More
Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. (HSR 33.15)

15.2

-

-

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 150 mm dia (HSR 33.16.2)

3

-

-

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete 150 mm clamp (HSR 33.17.2)

3

-

-

... More
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 150 mm dia (HSR 33.18.2)

3

-

-

... More
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yieldwithout sand content (beyond permissible limit), with requiredcapacity air compressor, running the compressor for requiredtime till well is fully developed, measuring yield of well by "V''notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (HSR 33.19)

18

-

-

... More
Supply of PVC pipe 6 kg/cm² pressure of ISI marked of Prince / Supreme/Skipper make (as approved by the Engineer-in-Charge). (NS) a) 6''(160 mm dia)

128

-

-

... More
b) 8'' (200 mm dia)

115

-

-

... More
c) 10'' (250 mm dia)

223

-

-

... More
d) 4'' (110 mm dia)

77.72

-

-

... More
Providing and fixing factory made precast RCC perforated drain covers, having strength not less than M-25 of size 600 mm x 600 mm x 50 mm reinforced with 8 mm dia 5 Nos. longitudinal & 5 Nos. cross sectional T.M.T loop bars, including 50 mm dia perforations @ 100 to 125 mm C/C including providing edge binding with M.S Flats of size 50 mm x 1.6 mm, complete in all respect. (NS) (based on HSR 33.5)

51

-

-

... More
Electrical work 114 to 225:- COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT Wiring for Light/Fan/Call Bell Point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. GROUP B (HSR 23.4.1.2)

25

-

-

... More
Wiring in PVC conduit system for 3- pin 5 amp. Plug point by using 2 no. 1.5 sqmm FRLS copper wire and 1 no. 1.5 sqmm FRLS copper wire for earthing , including providing 1 no. 5/6 Amp 3/5 pin socket and 1 no. 5/6 Amp switch required. Group B (HSR 23.4.4.2)

6

-

-

... More
Wiring in PVC conduit system for 3- pin 15 amp. Plug point by using 2 no. 4 sqmm FRLS copper wire and 1 no. 4 sqmm FRLS copper wire for earthing, including providing 1 no. 15/16 Amp 3/6 pin socket and 1 no. 15/16 Amp switch required. Group B (HSR 23.4.5.2)

6

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1)

80

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.3.6.3)

30

-

-

... More
COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED 23.5.6 Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1)

350

-

-

... More
COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED 23.5.6 Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.5.6.3 )

300

-

-

... More
Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia. (HSR 23.6.6.1)

80

-

-

... More
Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 25 mm dia. (HSR 23.6.6.2)

60

-

-

... More
Supply and erection of PVC conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC Pipe 20mm Dia (HSR 23.7.6.1)

100

-

-

... More
Supply and erection of PVC conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2)

400

-

-

... More
S/E of Fittings and Accessories. Providing and fixing Piano type accessories of approved make in existing Rate box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. (HSR 23.8.1.12)

23

-

-

... More
S/E of Fittings and Accessories. Providing and fixing Piano type accessories of approved make in existing Rate box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Call bell 220/230 volts musical type (HSR 23.8.1.6 )

5

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outerface plate including concealing the box in wall and fixing in position withinner plate and face plate with all labour and material required for the jobcomplete in all respects. 1 & 2 Modules (HSR 23.8.10.1)

58

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outerface plate including concealing the box in wall and fixing in position withinner plate and face plate with all labour and material required for the jobcomplete in all respects. 3 Modules (HSR 23.8.10.2)

23

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outerface plate including concealing the box in wall and fixing in position withinner plate and face plate with all labour and material required for the jobcomplete in all respects. 4 Modules (HSR 23.8.10.3)

1

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outerface plate including concealing the box in wall and fixing in position withinner plate and face plate with all labour and material required for the jobcomplete in all respects. 6 Modules (HSR 23.8.10.4)

19

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outerface plate including concealing the box in wall and fixing in position withinner plate and face plate with all labour and material required for the jobcomplete in all respects. 8 Modules (HSR 23.8.10.5)

7

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outerface plate including concealing the box in wall and fixing in position withinner plate and face plate with all labour and material required for the jobcomplete in all respects. 12 Modules (HSR 23.8.10.6)

7

-

-

... More
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in allrespect. 5 amp 1 way switch (HSR 23.8.11.1)

135

-

-

... More
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch (HSR 23.8.11.3)

27

-

-

... More
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket (HSR 23.8.11.4)

42

-

-

... More
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket (HSR 23.8.11.5)

61

-

-

... More
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Bell Push (HSR 23.8.11.6)

5

-

-

... More
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7)

30

-

-

... More
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate (HSR 23.8.11.10)

19

-

-

... More
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type (HSR 23.8.11.11)

13

-

-

... More
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA (HSR 23.22.1.4)

10

-

-

... More
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA (HSR 23.22.1.5)

2

-

-

... More
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 300 Amp, 25 KA (HSR 23.22.1.6)

1

-

-

... More
SITC Four pole ONLOAD Manual change over switch in SS enclosureof following Ratings 200 amp 415 volts (HSR 23.22.8.3)

1

-

-

... More
 Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 12 way. (HSR 23.22.4.3)

1

-

-

... More
 Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 16 way ( 2 incoming and 14 outgoing) (HSR 23.22.4.4)

2

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:-SP MCB 6-32 AMP (HSR 23.22.5.1)

100

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- SPN MCB 6-32 AMP (HSR 23.22.5.3)

7

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- SPN MCB 40-63 AMP (HSR 23.22.5.4)

1

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- TPN MCB 40-63 AMP (HSR 23.22.5.6)

1

-

-

... More
S/E of blanking sheet in existing distribution board. (HSR 23.22.7)

5

-

-

... More
Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc.at both ends (Upto length of one metre):- Size 20 mm dia (HSR 23.23.1.2)

7

-

-

... More
Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc.at both ends (Upto length of one metre):-     Size 25 mm dia (HSR 23.23.1.3)

7

-

-

... More
Supplying and drawing of 1no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required (HSR23.23.9)

400

-

-

... More
Dismantling of old wiring points (surface wiring system) including necessary repairs to wall etc. Light, fan or call bell Point in cluding circuit / sub sub main wiring (HSR 23.25.1.1)

81

-

-

... More
Dismantling of old wiring points (surface wiring system) including necessary repairs to wall etc. Wall socket Point in cluding circuit / submain wiring (HSR 23.25.1.2)

50

-

-

... More
Dismantling of old wiring points (reces wiringg or partly recess surface system, recess conduit and box not to be dismantaled) including necessary repairs to wall etc. Light, fan or call bell Point in cluding circuit / submain wiring (HSR 23.25.2.1)

7

-

-

... More
Dismantling of old wiring points (reces wiringg or partly recess surface system, recess conduit and box not to be dismantaled) including necessary repairs to wall etc. Wall socket Point in cluding circuit / submain wiring (HSR 23.25.2.2) 

6

-

-

... More
EARTHING AND LIGHTING ARRESTOR Earthing with G.I earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. as required.(HSR 24.1.1)

14

-

-

... More
Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2)

14

-

-

... More
Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required (HSR 24.1.4).

6

-

-

... More
Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode (HSR 24.1.5)

6

-

-

... More
Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.9)

60

-

-

... More
Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.10)

120

-

-

... More
Providing and laying earth connections from earth electrode with 4.00mm dia G.I. wire in 15mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11)

105

-

-

... More
Providing and fixing 4.00mm dia G1.Wire on surface or in recess for loop earthing as required. (HSR 24.1.13)

45

-

-

... More
Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm cable 2 to 4 core ( HSR 24.2.7.2)

2

-

-

... More
Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm cable 2 to 4 core (HSR 24.2.7.3)

4

-

-

... More
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm (HSR 24.2.8.4)

4

-

-

... More
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm (HSR 24.2.8.7)

8

-

-

... More
Supply and erection of 32mm dia metre 1.5 m long bracket (B-class) making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing of GI. bracket on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections.(HSR 24.4.3)

6

-

-

... More
Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB, end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge7 Metre Long pole with top dia 75 Omm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm (HSR 24.4.8.5)

8

-

-

... More
S/E of mark double walled corrugated ( DWC) HDPE pipe 10 kg/sqcm, laid 0.75 Mtr. Below ground level including diging and refilling of earth including cost of suitable size socket/ cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer incharge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia (HSR 24.5.2.3)

600

-

-

... More
S/E of mark double walled corrugated ( DWC) HDPE pipe 10 kg/sqcm, laid 0.75 Mtr. Below ground level including diging and refilling of earth including cost of suitable size socket/ cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer incharge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia (HSR 24.5.2.4 )

100

-

-

... More
S/E of LED street light of system voltage ≤ 70/72 W IP 66 Multiple LED with lens optics and pressure die-cast aluminium housing for effective thermal management. Total system lumen of ≤ 70 watt LED should be 7800 or above in cool day light (5700K), Lumen efficacy 110 lm/W, Power factor ≥ 0.95, CRI ≥70, Average life ≥50000 hours, complete with all acessories as required with connections. Make Havells , Bajaj , Philips. (NS)

14

-

-

... More
S/E of PVC unsheathed FRLS copper conductor cable single core 1100 volt grade in existing pipe of suitable size excluding cost and erection of pipe. (NS) Size 1.5 sqmm.

3000

-

-

... More
S/E of PVC unsheathed FRLS copper conductor cable single core 1100 volt grade in existing pipe of suitable size excluding cost and erection of pipe. (NS) Size 04 sqmm.

1700

-

-

... More
S/E of PVC unsheathed FRLS copper conductor cable single core 1100 volt grade in existing pipe of suitable size excluding cost and erection of pipe. (NS) Size 06 sqmm.

600

-

-

... More
S/E of AC ceiling fan capacitor type complete with shackle 5 star rating, 300mm down rod etc.(NS) i) 1200mm sweep. Make: Usha, Orient, Crompton

13

-

-

... More
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod etc.(NS) i) 1400mm sweep. Make: Usha, Orient, Crompton

17

-

-

... More
S/E of LED tube rod 20watt double side connections with 4 feet long housing made of CRCA sheet steel with epoxy powder coated white after phosphochromate treatment and 2 nos. lamps push fit type white polycarbonate holders and reflector made of white powder coated CRCA sheet total system lumen of 20watt LED should be 2200 or above in cool day light ( 5700K to 6500K ) PF 0.95 , CRI 80 , Avg. life 50000 hours complete with mounting bracket and accessories as required with connections Make Philphis , Havells , wipro , Bajaj (NS)

24

-

-

... More
S/E of propeller type AC ventilating fan (exhaust fan) with necessary earthing arrangements of fan with shutter complete in all respects Size 380mm(15”) sweep (Heavy Duty) 900 RPM Make: Orient, Usha, Crompton,Havells. (NS)

4

-

-

... More
Supply installation testingan commissioning of wall free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet required hardware 3 mm thick bakelite sheet providing all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of zinc/Red oxide primer followed by 2 coats of powder cating in grey or required shade after rinsing. the panle having PU/Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/ switch wear.Transparent arcylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber Extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra tiems side walls and cable alley compartments shall be haiving bolted type doors with detachable extension type strcture. the panel will be complete with control wiring ( copper) and fuse protection ( only outer area on all sides shall be measured ) (NS)

12

-

-

... More
Supply and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing go same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat srinkable PVC insulation complete in all respect. (NS)

30

-

-

... More
Pdg. And fixing digital metering equipment for LT cubical panel consisting of 96 mm x 96 mm 0-500 V, meter with selector switch amp. Meter (of required ratio upto 600/5 amp) with selector switch and required C.Ts 3 Nos.. A set of 3 No. phase indication lamps RYB LED (NS)

1

-

-

... More
S/E of recessed type 42 watt full window glare free opal difffuse LED panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 5100 or above in cool day light (5600k to 6500k), Power factor 0.95, CRI (Ra) 80, LED lamp efficiency ≥140 lm/w, Average life 50000hours, complete with all accessories. (Industrial) Make Havell's or Philiphs , Bajaj (NS)

82

-

-

... More
Dismantling old DBs, BDBs and returning old material to store with in the radius of 2km. (NS)

7

-

-

... More
Dismantling of old electrical panels (Main E.nitches) and return the material to store with in the radius of 2km.(NS)

3

-

-

... More
Supply & erection of under ground cable lose in existing pipe or trenches complete with necessary connecitons:- size 2 x 16 sqmm (armoured) cable (NS)

500

-

-

... More
Supply & erection of under ground cable lose in existing pipe or trenches complete with necessary connecitons:- size 4 x 50 sqmm (armoured) cable (NS)

130

-

-

... More
S.I.T.C of push ON/OFF type 25 A Modular type motor starter swithch ( white color) fr AC'S including the cost of petty meterial required to complete the job upto entire satisfaction of Engineer-in Charge. (NS)

30

-

-

... More
S/E of single Arm bracket 1.5 mtr long 40 mm dia GI bracket with suitable sleeve as per pole top dia galvanied with all petty material required to complete the job for entire satisfaction of Engineer in Charge. (NS)

8

-

-

... More
S/E of fancy pole of 3 mtr long made of cast iron base part and mild steel grooved pipe section and joined together by means of threaded joints alongwith a service window provided in the bottom part of the pole to accomadate a 6 amp. SP MCB and 30 amp. Connector for mains connection. A cast aluminium embellishment shall be fitted to the grooved steel pole by grub screw fixing to enhance the decorative look of the pole. The Pole shall be duly pre-treated by shot blasting process and painted in Poly-Urethane paint in approved colour shade having a minimum 300 salt spray hours quoting on the pole and should have minimum 90 micrones DFT. Pole Make : Twinkle, Homdec Lighting LED. Specifications:- LED should be ≤ 30 watt with cast amuminium housing diffuser translucent poly carbonate having quoting PU/Polyster LED should be ≤ 30 watt with seprate driver placed integrally in luminaire housing. Driver should be of THD ≤10% and power factor above ≥ 0.95, provided. LED lumen should be ≥ 3600. The luminaire Urethane/Polyster quoting in required colour shade. LED CCT should be 3000K ingress protection IP 65, power rating 230 volts, AC 50 HZ. LED Make :TWINKLE/K-LITE (NS)

12

-

-

... More
Suppy,Installation,Testing and Commissioning of Automatic voltage stablizer of single phase 5.00 KVA capacity copper wound heavy duty 100 volt up of Logicstate,Bluse star, V-guard make ISI mark complete in all respect. (NS)

20

-

-

... More
Providing and installing split type air conditioners, five star rating inverter type with copper coils 2.0 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-410-A suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:- (i) Cooling coil row -3 Nos. (ii) Air flow (CMH) -1450 cum/ hr. (iii) Sound level (H/M/L)- 41/38/34/25(silent mode) (iv) Louvers swing- 3D + 3D Auto etc. complete in all respect MAKE :- O General/Toshiba/Mitsubishi (Heavy Industries) (five star rating) Model as approved by the Engineer-in-Charge. (NS)

20

-

-

... More
Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. (NS) NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing & laying refrigerant pipe line of four metres length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing & laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring ; suitable electric wiring and switch should be provided with in 4 metres of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4") (ii) Gas line:- 15.88mm(5/8") 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit. (NS)

80

-

-

... More
Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts & bolts etc. of best quality complete in all respect (NS)

20

-

-

... More
CENTRAL PROCESSING UNIT FOR MICROPHONES:- Supply Installation Testing and Commissioning of Digital central controller for powering and controlling of discussion devices. The controller should have connections at rear to connect audio peripherals or conference dome cameras. The system settings such as microphone management should be configurable from software on a PC/tablet using web browser. The number of open microphones should be controllable from either the control unit itself or web based software. The controller should be able to accommodate upto 10 number of open microphones. The control unit should be capable of connecting to cameras for conference room, external wired/wireless microphone, sound reinforcement systems, audio equipment, external audio processor, telephone coupler, external recorder or computer. The control unit should have the following modes : Open mode - Participants speak by pressing their PTT button. When max no. of open mics reached the next participant is automatically waitlisted. Over ride mode - when max no. of open mics reached the first mic to be switched on is automatically switched off. Voice activated mode - mics switch on their own when participant speaks near the mic. PTT mode - Participant presses his PTT button and the mic is switched on till the time button is pressed. • Inbuilt MP3 recorder which can support upto 128GB flash drive or 4000 hours of discussion. • Inbuilt digital acoustic feedback suppressor to control acoustic feedback or howling in the system. • No. of discussion devices - max 40 per trunk line. • Sample rate 44.1kHz. • Frequency response - 30Hz - 20kHz. • S/N 94dBA. MAKE:-Beyerdynamic/ Bosch/Brahler (NS)

1

-

-

... More
CHAIRMAN UNIT (SHOT GUN):- Supply Installation Testing and Commissioning of digital chairman unit with priority, inbuilt speaker, PTT button and 48 cm long gooseneck microphone. The unit should have following features: • Possible to speak indicator - The microphone should have a white LED indication which shows when the microphone can be activated; • Request to speak indicator - the microphone should have a green LED indicator when the microphone is in queue to be activated; • Built in loudspeaker with volume controller; the unit shoul dhave built in head phone socket with volume control for the same. • The discussion unit should have immunity from mobile phone signals. • Frequency response - 200Hz-12.5kHz; • Loud speaker output - 72dB SPL MAKE:-Beyerdynamic/ Bosch/Brahler (NS)

3

-

-

... More
DELEGATE UNIT (SHOT GUN):- Supply Installation Testing and Commissioning of digital delegate unit with inbuilt speaker, PTT button and 48 cm long gooseneck microphone. The unit should have following features: • Possible to speak indicator - The microphone should have a white LED indication which shows when the microphone can be activated; • Request to speak indicator - the microphone should have a green LED indicator when the microphone is in queue to be activated; • Built in loudspeaker with volume controller; the unit shoul dhave built in head phone socket with volume control for the same. • The discussion unit should have immunity from mobile phone signals. • Frequency response - 200Hz-12.5kHz; • Loud speaker output - 72dB SPL MAKE:- Beyerdynamic/ Bosch/Brahler (NS)

26

-

-

... More
DSP WITH USB:- THD+N (22Hz to 22kHz) 0.002% (1kHz @ +4dBu)EIN 125dBu, unweighted (20Hz to 20kHz)Dynamic Range 110dB, unweighted,Propagation Delay 4ms, Crosstalk, input to input, 1kHz 110dB Sampling Rate 48kHz A/D-D/A Converters 32-bit Acoustic Echo Cancellation Requires HearClear™ license; 250ms latency at eight channels, 100ms at 16 channels BTU/Heat Load 44 BTU/hr, Processor Type 40-bit floating point Phantom Power +48VDC (with XC-SML) up-to 75mA maximum Power Supply IEEE 802.3af, Class 0 Power-over-Ethernet Power Consumption 13W maximum Ambient Operating Temperature 32-104°F (0–40°C) Humidity 0–98%, non-condensing Altitude 0-6,600 feet (0–2000 Meters) MSL Network Connections 2x RJ45 (≥Cat 5e) including dedicated 1000Mbps Dante™ connection and, separate Ethernet port for control and Power-over-Ethernet USB (with XC-SUB) Bit depth: 16-bit, Number of channels: 2x2, send and receive, Driver sample rate: 48kHz Card sample rate: follows DSP settings, Connector: USB B, female Dante™ 4x4 bi-directional; AES67 MAKE:-Xilica/Audio Technica/BSS (NS)

1

-

-

... More
AMPLIFIER:- Channels 4 Sensitivity (for full rated power at 8 ohms) 0.7V RMS Rated Power Output (per channel @ 4 ohms) 300W Analog Input Signal to Noise Ratio (ref. rated power, 100V, 20Hz - 20kHz) at 8 ohms) 104dB THD (full rated power, 20 Hz - 20 kHz) 0.35% Damping Factor (20 Hz to 100 Hz) 1000 Frequency Response (8Ω, 20 Hz - 20 kHz) +/-0.5dB Crosstalk (below rated power) 20 Hz to 1 kHz 80dB Input Impedance (nominally balanced, nominally unbalanced) 20 kΩ balanced, 10 kΩ unblanced Dimensions (inches) (W x H x D) (depth not including 1.3 inch front panel protrusion) 19 x 3.5 x 12.25 Weight 16.13 lbs (7.31 kg) Power Supply Connector "Standard IEC type 320 inlet for detachable connector 100 – 240V~" MAKE:-Crown/JBL/Bose (NS)

1

-

-

... More
WALL/CEILINGMOUNT SPEAKER:- Supply Installation Testing and Commissioning of 30W Premium-sound cabinet loudspeaker High-Fidelity music and speech reproduction, Selectable 8 ohm, 70V and 100V inputs, Safety acc. to EN60065, water production acc. to EN60529 IPx4. Power tapping - 30/15/7.5/3.75W, Sound pressure level at rated power/1 W(1kHz, 1 m) 105/90 dB (SPL), Effective Frequency Range (- 10dB) 100Hz to 19kHz. MAKE:-JBL/Bose/Bosch (NS)

12

-

-

... More
S.I.T.C. of 86" Intractive flat Panel, IR touch technology, IPS Panel UHD Native Resolution ( 3849 x 2160 ), Brightness 330 Nits; Contrast ratio 1100:1, response time :8ms, Orientation Landscape Connectivity. ( Input ) Video / Audio HDMI (3), RGB / Audio in(input) External Control rS232C In,RJ45 (Input) USB USB 2.0 (3, Front : 2ea, Bottom side :1ea Only for software. Audio HDMI (1), Optical Output / Audio Out with OPS i5 system Touch type IR. Available object size for touch Ø3 mm ↑ Response Time 60ms ↓ (Andriod) / 100ms ↓ (Windos) Accuracy 1.5mm Unreface USB 2.0 Protection Glass Thickness 4T (Anti - Glare) Make Sony/Panasonic/Samsung (NS)

1

-

-

... More
S/I/T/C OF 55" LED TV/DISPLAY:- 55" 4k Display panel for viewing content- LED display, HDMI X 2, DVI X 1, DP X 1, VGA X 1, Video IN X 1, Component x 1, USB X 2, RS232 X 1, Audio IN X1, 20W in built speaker, IPS LED display, USB media player, Auto Input search, Auto sleep, Auto wakeup, Auto source detect MAKE:- LG/SAMSUNG/SONY (NS)

1

-

-

... More
S.I.T.C. of Intractive Digital Podium system with 16" intractive screen EMR technology, also available Goosneck Microphone inbuilt Aluminium plated system Interface : USB, Pressure sensitive. Still image Resolution : XGA,SXGA,720P,1080P FRAME RATE 20 FRAMES/SEC. Image Mode: Normal/Photo/Text/Slide/Film/Gray. Inputs-VGAx2, HDMIX 1 Video x 2, Audio x 2 Outputs - VGA x 2, hHDMIx 1 VIDEO X1 AUDIO X1. Make ATDSC/LABWE/AHA etc (NS)

1

-

-

... More
2X2 DA:- Supply , Installation , Testing & Commissioning of 4K@60Hz HDMI 2 in 2 out switcher+scaler , realize 2 HD signals can be auto or last connected input whenever the currently active video signal is interrupted or whenever a higher−priority video signal is detected switched at will distribute 2 devices to connect to display and control classified and non−classified computers without compromising security. UHD resolution support up to 3840×2160 @60Hz (4:4:4) unit should have minimum frequency bandwidth of 18Gbps (3.4 Gbps per lane), each input signal should reconstituted into a new signal before being output thereby eliminating any jitter component. Should support HDCP 2.2 and all signal paths should be fully buffered to prevent cross talk auto EDID management and HDMI v2.0 Audio and Video are synchronized audio separation function. Max pixel clock 600 MHz * Deep Color 36bit. Audio format DTS-HD/Dolby-D3:E3TrueHD/LPCM7.1/DTS/Dolby-AC3. Compatible with Windows series, Mac, Linux no need to install drivers IR Remote and panel button control etc. as reqd. safety CE, c-UL, UL MAKE:-Beyerdynamic/ Extron/ Kramer (NS)

1

-

-

... More
S/I/T/C of 5.5 KVA( 4.4.KW) Online UPS with 30 minutes back up time. DC voltage system-Default 192 VDC, Adjustable 216VDC Phase- Single with ground Input: Nominal Voltage-208 VAC/220 V C/230VAC Acceptable Voltage Range- 165-285 VAC Frequency Rage- 40HZ-55Hz@ 50 Hz system Output Nominal voltage- 208 VAC/220 VAC/230/VAC AC voltage regulation- + 1 % Battery model Frequency range: Mains mode (synchronised range) 45Hz-55Hz/Battery Mode 50Hz +01 Hz Transfer time AC to DC mode- Zero Inverter to bypass mode- Zero Bypass to inverter mode- 5ms Wave form Battery mode- Pure sine wave Efficiency –AC mode/Battery mode- 87%/91%External Battery Recommended Battery type :.SMF battery with charger cut off voltage adjustable from LCD digital Battery charging AMPERE : 2/4/6 AMP (Default 8 AMP) No. of batteries 16/18 batteries Indicators LCD display – Load levels, battery level AC mode Battery mode bypass made and fault indicators Battery mode sounding every 4 seconds Low battery sounding every second Overload-sounding twice every second Fault continuously sounding.including cost of petty material required to complete the job. Make; Luminous, Eaton, Micro tek (NS)

1

-

-

... More
S/I/T/C of Wireless Handheld Microphone Wireless Handheld Microphone system , Carrier frequency range 500.1 MHz-864.9 Mhz, Switching bandwidth 30.5 Mhz (depending on local regulations), Auio bandwidth 35 to 20,000 Hz, Signal to Noise 120 Including the cost of petty material required to complete the job. Make: Bose/AKG(WMS420 vocal) /Audio tek (SV607/Audiotech SV100). (NS)

2

-

-

... More
S/I/T/C of Wireless Presenter Set Microphone Wireless Presenter Set Microphone system, carrier frequency range 500.1 MHz-864.9 MHz, Switching bandwidth 30.5 MHz (deepening on local regulations), Audio bandwidth 35 to 20,000Hz, Signal to Noise 120 dB-A, Upto 16 pre-programmed frequencies per group. Including the cost of petty material required to complete the job. Make: Bose/AKG(WMS420 Presentor)/Audio tek (NS)

2

-

-

... More
S/I/T/C of Connectors Connectors & accessories required for complete setup Make: Customized (NS)

1

-

-

... More
Supply Installation testing & commissioning of AP management License including cost of petty material required to complete the work upto the entire satisfaction of Engineer In charge Make : RUCKUS/ CISCO/ ARUBA (NS)

3

-

-

... More
The access point should provide for concurrent support for high definition IP video, voice and data application without needing any configuration. The feature should be Support RF auto-channel selection by the following methods: a) measuring energy levels on the channel; b) monitoring for 802.11 signal structures and ; © detecting radar pulses. Other similar forms of smart selection shall also be accepted. Channel selection based on measuring throughput capacity in real time and switching to another channel should the capacity fall below the statistical average of all channels without using background scanning as a method. AP should provide minimum 23 dBm radio output power for 2.4Ghz and 5GHz both (EIRP should be limite as per govt. regulation for indoor AP’s. Should support transmit power tunning in 1dB increments in order to reduce interference and RF hazards. Device antenna gain (intergrated must be at least 3dBi and should provide automatic interference rejection of about 10 dB. Upto 16BSSIDs per AP for multiple differentiated use services (e.g. voice) Shold support upto 500 clients per AP. Should support IPv4 and IPv6 from day one. The access point should support following security mechanism WEP, WPA-PSK, WPA-TKIP, WPA2 AES, 802.11i. System should support Authentication via 802.1X, local authentication database, support for RADIUS and active directory. Mechanism for physical device locking using padlock/Kensington lock/ equivalent. Operating Temperature: 0 degree Celsius – 40 degree Celsius Operating Humadity upto 95% non-condensing. Should be UL 2043 plnum dated and comply to WEEE/ROHS Should be EN 60601-1-2 Medical Complaint. Should be WPC approved; ETA certificate to be enclosed Make RUCKUS/ CISCO/ ARUBA Including the cost of petty material required to complete the job (NS)

3

-

-

... More
S/I/T/C of 8 port layer 2 manageable switch with power on Ethernet (POE) enabled, with 8 nos. 10/100/1000 base tx POE port with to SFP Port one no. dual personality GBE Port for copper/fiber uplink, 20GBPS switching capacity, 14.88 MPPS forwarding performance, maximum power consumption 85 WATT, including the cost of petty mater required to complete the job and 3 years warranty upto entire satisfaction of Engineer-in-Charge. (NS) Make: CISCO/RUCKUS/ALCATEL

1

-

-

... More
Supply Installation testing & commissioning of 17U Server rack with Accesserieoes including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. MAKE :VPRO/Dlink/I-DYNAMIC (NS)

1

-

-

... More
Supply, Installation, Testing and Commissioning of Audio cable For Lecture Hall high−quality twisted pair cable designed for connecting speakers and amplifiers Material: Bare Copper Size: 2x16 AWG (26/30) Material: PVC Diameter: 2.0±0.09 mm Average Thickness: 0.261mm Color: Color coded — Black & red, Material: PVC Diameter: 5.6 ± 0.19mm. MAKE : TEKWIN/KRYSTAL/KRAMER/BELDEN (NS)

200

-

-

... More
Supply, Installation, Testing and Commissioning of HDMI Cable 10 Meters For Lecture Hall : High Speed HDMI Cable; Ethernet, 3D, 4K, Audio Return Supported;Gold Plated Connector; Bare Copper Connector for high quality transmission; full metal jacket with shielding; 0% transmission loss. MAKE : Stacker/Aten/Kramer/TEKWIN/WBOX (NS)

2

-

-

... More
Supply, Installation, Testing and Commissioning of Cable 5 Meters : High Speed HDMI Cable; Ethernet, 3D, 4K, Audio Return Supported;Gold Plated Connector; Bare Copper Connector for high quality transmission; full metal jacket with shielding; 0% transmission loss. MAKE : Stacker/Aten/Kramer/TEKWIN/WBOX (NS)

2

-

-

... More
Supply, Installation, Testing and Commissioning of XLR cables - Male,females, Speakon connectors, conducting, solding etc . (NS)

1

-

-

... More
VIDEO CONFERENCE UNIT:- S/I/T/C OF full HD 20X Zoom camera with HDMI,USB,LAN ports of features advanced ISP processing algorithms and exceptional Pan-Tilt mechanism to provide high resolution, vivid performance and smooth moves. HD Pan/Tilt/Zoom (PTZ) camera has USB 3.0 and HDMI and IP video output interface , equipped with a high performance imaging, fine detail, and color rendering with 1/2.8″ low-noise, HD CMOS image sensor with Full HD 1080p output resolution and a high dynamic image of 60 fps. The superior 20x optical zoom lens,wide shooting angle and achieves high-speed, quiet, and precise positioning with smooth PTZ operations. There are up to 255 preset setting movements and stable remote controlling for displaying effective and efficient presentations supports VISCA, Pelco-D, and Pelco-P camera control protocols TCP/IP, RS-232, USB, and IR control,remote control ,Minimum Illumination 0.5 Lux @ F 1.8 (AGC ON) ,Focal Length 5.5 – 110 mm (20x), F Number F1.6-F3.5, Field of View 55.8° (wide) – 3.2° (tele) , Pan/Tilt Rotation -170°∼+170°, -30°∼+90° , Network Protocol RTSP, RTMP, ONVIF , GUI-based configuration. MAKE:-Beyerdynamic/Panasonic/Sony (NS)

1

-

-

... More
S/I/T/C OF ceiling/wall mounting kit for camera MAKE:-Beyerdynamic/Panasonic/Sony (NS)

1

-

-

... More
S/E Oof USB Cable for connecting the Camera of different sizes. MAKE:-Aten/Kramer/Bestnet (NS)

1

-

-

... More
Supply Installation testing & commissioning of Zoom License for software for video confrecing including cost of petty material required to complete the work upto the entire satisfaction of Engineer In charge Make : Zoom (NS)

1

-

-

... More
S/I/T/C OF ceiling/wall mounting Bracket for IFP. MAKE:-JBL/Bose/Bosch (NS)

1

-

-

... More
Testing, Commissioning, Installation and Programming Charges for the complete work. (NS)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.