Chaudhary Charan Singh Haryana Agricultural University Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Chaudhary Charan Singh Haryana Agricultural University Tender

Works
Eprocure
Opening Date7 Jul 2023
Closing Date17 Jul 2023
Tender Amount₹ 16,00,000 
Notes
Download

Costs

  • EMD

    ₹ 32,000
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling cement conglomerate / terrazzo floors 25 mm to 50 sqm mm manually/ by mechanical means and disposal of material within standard lead as per direction of Engineer- in-charge. (HSR 5.42)

98.7

-

-

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead). (HSR 5.45)

31.67

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)

3.76

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: (HSR 6.14.1) 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size)

1.27

-

-

... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diaMeters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D kg or more. (HSR 6.33.6)

29

-

-

... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more. (HSR 6.34.6)

107

-

-

... More
Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.21.2)

11.55

-

-

... More
Brick work with common burnt clay non-modular bricks of class designation 10 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.22.2)

4

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platfonns, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab over 0.50 sqm (HSR 8.26.2.2)

17.08

-

-

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing periMeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and30 mm long, the periMeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of periMeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charae but excludina the cost of painting with 12.5 mm thick tapered edge gypsum moisture resistant board (HSR 9.46.3)

21.79

-

-

... More
Providing and Fixing 15 mm thick densifled tegular edged eco friendly light weight calcium silicate false celling tiles of approved texlure of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm interval and laying 15 mm thick densifled edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixlures, smoke detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ·r, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. (HSR 9.48) Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, noncombustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/mK.

81.08

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (HSR 10.63.2)

98.7

-

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (HSR 10.67.2)

14.95

-

-

... More
Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm (HSR 10.70.2)

113.85

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1 :4 (1 cement: 4 fine sand) (HSR 11.6.1)

35.04

-

-

... More
20 mm cement plaster of mix 1 :6 (1 cement: 6 coarse sand) (HSR 11.10.2)

31.67

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (HSR 11.60)

226.44

-

-

... More
Distempering with 1st quality acrylic distemper (ready mixed) having voe content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work (HSR 11.65.1)

226.44

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer (HSR 11.67.1)

226.44

-

-

... More
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 11.76)

103.5

-

-

... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)

103.5

-

-

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)

103.5

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (HSR 12.37.1)

6.48

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. (HSR 12.37.3)

36.53

-

-

... More
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 356 4, embossed on the body, door weight up to 35 kg and door width up to 7 00 mm), with necessary accessories and screws etc. complete. (HSR 12.88)

4

-

-

... More
Providing and fixing of roller blinds on windows complete with material and labour complete with push up & down arrangement as per approved design /colour and Engineer-in-charge. (HSR 12.114)

12.69

-

-

... More
Providing and fixing at all height wall panelling with phenol bonded Bamboo Mat board confonning to IS:13958-1994 including providing and fixing to frame work made of 50mm x 50mm hardwood plugs including cutting brick work and fixing in cement mortar and making good the wall etc. and also providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws all complete as per direction of Engineer-in-Charge 12mm thickness (HSR 18.23.2)

18.36

-

-

... More
Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). Two way (HSR 22.8.2)

3

-

-

... More
Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board 510x1040 mm bowl depth 225 mm (HSR 22.10.1.2)

3

-

-

... More
Providing and fixing CP Brass Single lever telephonic wall mixer of quality &make as approved by Engineer in charge. 15 mm nominal dia (HSR 22.12.1)

1

-

-

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (HSR 22.15)

3

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes (HSR 22.85.2)

25.23

-

-

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore (HSR 22.106.1)

4

-

-

... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (HSR 30.21)

133.96

-

-

... More
Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of malba/ debris/rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-inCharge. (HSR 30.52.1) For door/ window/ clerestory window

2.66

-

-

... More
Providing and fixing 12 mm thick Bison Board Panels in existing duct frame (excluding cost of frame) of approved make including cutting, nails, screws and removing of existing damaged board etc. complete in all respect as directed by Engineer-in-charge. (NS)

4.32

-

-

... More
Providing and fixing PVC wall paneling consisting of 7mm thick cactus make hollow PVC section, PVC U section beading of size 25mmx8mmx12mm and PVC angle nosing of size 25mmx25mmx1.5mm including cost of PVC gutties, screws, jointed with polyfix (instant glue), complete in all respect as per drawing or as directed by Engineer-in-Charge (NS)

18.36

-

-

... More
Electrical work 41 to 73:- COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A (HSR 23.4.1.1)

42

-

-

... More
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A (HSR 23.4.4.1)

6

-

-

... More
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A (HSR 23.4.5.1)

28

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) (HSR 23.5.6.4)

172.5

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.6)

115

-

-

... More
Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia (HSR 23.7.6.2)

172.5

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects 1&2 Modules (HSR 23.8.10.1)

17

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects 3 Modules (HSR 23.8.10.2)

29

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects 8 Modules (HSR 23.8.10.5)

4

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects 12 Modules (HSR 23.8.10.6)

4

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch (HSR 23.8.11.3)

25

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket (HSR 23.8.11.5)

32

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7)

9

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type (HSR 23.8.11.8)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate (HSR 23.8.11.10)

9

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable (HSR 23.8.11.11)

3

-

-

... More
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. Triple pole MCCB 16 amp to 100 amp , 25 KA (HSR 23.22.1.3)

3

-

-

... More
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work SPN DB Double Door 4 way ( 2 incoming and 2 outgoing) (HSR 23.22.4.1)

4

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1)

40

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCB's TRIPLE POLE (HSR 23.22.5.6)

4

-

-

... More
Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and shealed in existing pipe/Channel and making necessary connection complete in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. 2 pair Telephone wire (HSR 23.23.8.1)

115

-

-

... More
S/E/T/C of Cat-6 cable in existing PVC conduit /PVC channel complete in all respect with all labour and material required to complete the job in all respect. (HSR 23.23.9)

172.5

-

-

... More
S/E of reccessed type≤42 watt fullwindow glare free opal diffuse LED Panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated whire housing. Total system lumen of 42 watt LED should be 5100 or above in cool dry light (5700K), Power factor≥0.95, CRI (Ra)≥80, LED LAmp efficiency≥140lm/w, Average life50000 hours, complete with all accessories as required with connections including 3 year defect liability period and free replacement in case of non functioning of the light fixture. Make: Bajaj, Havells, Philips (NS)

18

-

-

... More
Providing and installing split type air conditioners, five star rating inverter type with copper coils 2.0 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-410/ R-32 suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:- (i) Cooling coil row -3 Nos. (ii) Air flow (CMH) -1450 cum/ hr. (iii) Sound level (H/M/L)- 41/38/34/25(silent mode) (iv) Louvers swing- 3D + 3D Auto etc. complete in all respect MAKE :- O General/Mitsubishi (Heavy Industries) (five star rating) Model as approved by the Engineer-in-Charge. (NS)

5

-

-

... More
Suppy,Installation,Testing and Commissioning of Automatic voltage stabilizer of single phase 5.00 KVA capacity (Haevy duty) copper wound heavy duty 100 volt up of Logicstate,Blue star, V-guard make ISI mark complete in all respect.(NS)

5

-

-

... More
Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts & bolts etc. of best quality complete in all respect (NS)

5

-

-

... More
Providing and fixing extra copper tubing/refrigerant pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. (NS)

10

-

-

... More
Providing and fixing UPVC pipes of 25 mm sizes for disposal of condensed water drainage from indoor unit to nearest disposal point in toilet/ outside as per direction of the EIC/ consultant complete in all respect (NS) Make:- Prince/Supreme/Finolex

15

-

-

... More
S/I/T/C of push ON/OFF type 25 A modular type motor starter switch (white colour) for AC's including the cost of petty material required to complere the job upto entire satisfaction of Engineer In-Charge. (NS) Make:- Schnelder/Crabtree/Athena

6

-

-

... More
S/E of AC ceiling fan capacitor type complete with shackle, 300 mm down rod and regulator. {NS} (i) 1400 mm sweep, Make:- Orient, Crompton

8

-

-

... More
Supply installation testing and commissioning of wall free mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3 mm thick backlite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 caot of zine/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rising, the panel having PU/Neoprene rubber gasket of not less than 3 mm thickness separate dectachable gland plate MS base channel hinged door with inter locking arrangement fo equipment/switch wear as per details. (NS)

5.75

-

-

... More
Supply and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing go same in existing panel including bending, cutting in required shape and size insulation with colour coding heat srinkable PVC insulation complete in all respect. (NS)

6

-

-

... More
Supply & erection of Under Ground Aluminium (Armoured) cable loose in existing pipe or trenches complete with necessary connections:- Size 4x50sqmm. (NS)

17.5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.