Chaudhary Charan Singh Haryana Agricultural University Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 15,000Document Cost
₹ 1,000Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_HRY_222030_1Bid Award Id
ViewTender No
3287-CTender Authority
Chaudhary Charan Singh Haryana Agricultural University ViewPurchaser Address
-Website
http://https://www.hau.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead
Of area beyond 3 sq. metres (HSR 5.30.2)
3
-
-
... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles above 25 mm and up to 40 mm (HSR 5.43.2)
81.2
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level:
1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)
0.06
-
-
... More
Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.
1:1½:3 (1 Cement: 1½ coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size) (HSR 6.3.1)
1.67
-
-
... More
Providing and laying damp-proof course with cement concrete 1 :2:4 (1 cement : 2 coarse sand (zone-Ill): 4 graded stone aggregate 12.5mm nominal size) 40mm thick (HSR 6.8.2)
4.1
-
-
... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-1 O of approved quality using 1. 7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. (HSR 6.10)
4.1
-
-
... More
20 mm thick cement plaster damp-proof course 1 :3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded Vertical (HSR 6.12.1)
19
-
-
... More
Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.21.2)
20.2
-
-
... More
Brick work with common burnt clay non-modular bricks of class designation 10 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in :
Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.22.2)
13.55
-
-
... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing periMeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and30 mm long, the periMeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of periMeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charae but excludina the cost of painting with
12.5 mm thick tapered edge gypsum moisture resistant board (HSR 9.46.3)
19.6
-
-
... More
Providing and Fixing 15 mm thick densifled tegular edged eco friendly light weight calcium silicate false celling tiles of approved texlure of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including
both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and
secondary cross 'T' of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm interval and laying 15 mm thick densifled edges calcium silicate ceiling tiles of approved texture in
the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixlures, smoke detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size
85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ·r, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, noncombustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/mK. (HSR 9.48)
46
-
-
... More
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)
63.55
-
-
... More
Providing and laying of conglomerate floor 50mm thick cement concrete topping 1 :2:4 (HSR 10.7)
63.55
-
-
... More
Providing and laying cement plaster skirting up to 30 cm height, with cement mortar 1: 3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
18 mm thick (HSR 10.13.1)
3.45
-
-
... More
Providing and laying cement concrete pavement with 1: 2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. (HSR 10.16)
21.25
-
-
... More
Cement Concrete 1 :8:16 Flooring
Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. (HSR 10.100.2)
51.3
-
-
... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1 :6 (1 cement: 6 fine sand) (HSR 11.6.2)
53.7
-
-
... More
Pointing on brick work or brick flooring with cement mortar 1 :3 (1 cement : 3 fine sand): Flush / Ruled/ Struck or weathered pointing (HSR 11.25.1)
74.3
-
-
... More
Pointing on stone slab ceiling with cement mortar 1 :2 (1 cement : 2 fine sand): (HSR 11.29.1)
Flush/ Ruled pointing
14.5
-
-
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (HSR 11.60)
120
-
-
... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:
New work (two or more coats) over and including water thinnable priming coat with cement primer (HSR 11.64.1)
120
-
-
... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:
Water thinnable cement primer (HSR 11.67.1)
120
-
-
... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)
4.5
-
-
... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (HSR 13.28)
47
-
-
... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes (HSR 13.30.1)
575
-
-
... More
Compaction of Earthwork
Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications (in case of link roads earthwork to be done by villagers) (HSR 17.5.3)
139
-
-
... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (HSR 30.21)
55
-
-
... More
Providing and fixing marble strips of size 14mm to 17 mm and 40 mm wide in cement concrete flooring, complete in all respects as per drawing and design or as directed by Engineer-in-Charge. (NS)
113
-
-
... More
Providing and fixing 0.60 mm thick high strength galvanized colour coated steel sheets 45 cm wide gutters fixed in position with self drilling screws of approved shape and make, complete in all respects as per drawing & manufacture’s specifications and instruction of Engineer-in-Charge. (NS)
85.45
-
-
... More
Providing and fixing marble strips of size 14mm to 17 mm and 125 mm wide in cement concrete pavement and road, complete in all respects as per drawing and design or as directed by Engineer-in-Charge. (NS)
119
-
-
... More
EI work 34 to 47:-
Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B (HSR 23.4.1.2)
15
-
-
... More
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5
sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as
required.
Group B (HSR 23.4.4.2)
5
-
-
... More
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4
sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B (HSR 23.4.5.2)
5
-
-
... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable
1100 Volts grade in PVC Conduit etc as required.
1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1)
200
-
-
... More
1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.2)
180
-
-
... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.
1 & 2 Modules including combined plate for Telephone and data. (HSR 23.8.10.1)
5
-
-
... More
6 Modules (HSR 23.8.10.4)
5
-
-
... More
12 Modules (HSR 23.8.10.6)
2
-
-
... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing
distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1)
8
-
-
... More
6 amp. to 32 amp MCB's FOUR POLE (HSR 23.22.5.7)
1
-
-
... More
Supply and erection of double door sheet steel enclosure distribution board
suitable for MCBS and ELCBS etc. recessed in wall including bonding to
earth with all labour and material required to complete the job in all respect
up to the entire satisfaction of the Engineer-in-Charge of the work.
TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) (HSR 23.22.4.5)
1
-
-
... More
S/E of surface/wall mounted ≤20W integrated LED 4 feet fitting with Epoxy Powder coated white/Grey extruded aluminium channel housing for efficient heat dissipation. Total system lumen of 20 watt LED should be ≥ 2000 or above in cool day light (5700K to 6500K), Power factor 0.95, CRI 80, Average life 50000 hours. Complete with mounting Brackets & accessories as required with connections(Industrial)
Make: Philips, Havells, Wipro, Bajaj. (NS)
8
-
-
... More
S/E of propeller type AC ventalating fans (exhaust fan) with necessary earthing of fan complete with louver shutter, 380 mm sweep 900 RPM (Heavy Duty) Make:-Orient, Usha, Khaitan, Crompton (NS)
2
-
-
... More
Supply of wall mounted fans with necessary earthing arrangements of fan complete in all respect size 450 mm (18") sweep Make:-Orient, Usha, Khaitan, Crompton (NS)
5
-
-
Evaluation Notes How It Works ?