Chaudhary Charan Singh Haryana Agricultural University Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Chaudhary Charan Singh Haryana Agricultural University Tender

Works
Building Construction
Eprocure
Opening Date8 Aug 2019
Closing Date2 Nov 2019
Tender Amount₹ 11,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling concrete (HSR 8.6 (e)+note} (e) reinforced cement concrete with cleaning and straightening and cutting of bars if required

0.34

-

-

... More
Scraping {HSR 8.32 (a) +note} (a) White wash and colour wash

319.01

-

-

... More
Scraping {HSR 8.32(c)+note} (c) Cement plaster

10.06

-

-

... More
Dismantling white or coloured glazed tiles (to be carefully removed) (HSR 8.38+note)

21.82

-

-

... More
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in first storey upto 4 metres above plinth level (HSR 10.59+note)

0.04

-

-

... More
Providing and fixing false ceiling with 12 mm thick Gypsum Board fixed on M.S. steel runners frame including cost of screws angles, cleats, rawel plugs with taping, filling with Gypsum compound and applying priming coat etc. complete in all respects (HSR 13.91)

26.1

-

-

... More
Providing and fixing mineral fibre false ceilings tiles at all hieghts of size 595 x 595 mm of approved texture, design and pattern, the tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity K = 0.052 (-) 0.057 w/m k, Fire Performance as per (BS 476 pt - 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round gavanized iron section of 0.33 mm thick (galvanized @ 120 gsm) comprising of main T runners of 15 x 35 mm of length 3000 mm, cross T of size 600 x 600 mm suspended from celing using galvazied mild steel item (galvanizedd @ 80 gsm) 50 mm long 8 mm outerdiameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85 x 25 x 2 mm, spaced at 1200 mm centre of centre along main 'T'. The suystem should rest on periphery walls/partitions with the heop of GI perimeter wall angle of wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all hieghts, The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-charge. with or without groves (HSR 13.92)

118.53

-

-

... More
Providing and fixing vitrified tiles of size 600 x 600 mm of approved make in skirting / dado laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles (HSR 14.90) Note : Tile shall be of premium quality (first quality of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT, JOHNSONS & RAK ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this

7.28

-

-

... More
12 mm thick cement plaster 1:4 on walls (HSR 15.5+note)

7.62

-

-

... More
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead , linseed oil, varnish and chalk mitti including finishing the surface to required finish complete(HSR 16.1)

9.94

-

-

... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping, etc. (HSR 16.2)

9.94

-

-

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade (HSR 16.3)

9.94

-

-

... More
Painting two coats with synthetic enamel paint in all shades on old wood work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint (HSR 16.5)

51.18

-

-

... More
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces (HSR 16.25)

319.01

-

-

... More
Spirit polishing two coats including 2 coats of wood filler on new work (HSR16.44)

3.6

-

-

... More
Distempering with washable oil bound distemper (of approved manufacture) two coasts excluding priming coat on new work (HSR 16.57)

319.01

-

-

... More
Providing and applying two coats of white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc., complete (J.K/ Birla make). (HSR 16.81)

319.01

-

-

... More
Providing and fixing plywood, plain lining, butt-jointed, including, wooden plugs (Teak), placed at 45 cm to 60 cm centres, complete with necessary nails (frame work shall be payable extra)- (HSR 17.47(h)} (h) 12mm thick commercial ply wood .

9.94

-

-

... More
Providing and fixing Aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS;733 and IS; 1285 fixed with raw plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. aluminium sections shall be smooth rust free straight mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling C.P. brass/ stainless steel screws, all complete. (HSR 17.95) Fixed portion (Anodized Aluminium transparent or dyed to required shade according to IS;1868, minimum anodic coating of grade AC 15)

310

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS; 733 and IS;1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. Aluminium sections shall be smooth, rust free straight mitered and jointed mechanically wherever required including clear angle, Aluminium snap beading for glazing/ paneling C.P. brass/ stainless steel screws, etc. complete. (HSR 17.96) Shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including of cost of PVC/ neoprene gasket required including Aluminium fitting.

499

-

-

... More
Providing and fixing 12 mm thick pre laminated particle board flat pressed three layer or graded wood particle board conforming to IS;12823 grade I type II in paneling fixed in aluminium doors. Windows shutters and partition frames with CP brass/ stainless steel screws etc. complete. (HSR 17.97(b)} (b) Pre-laminated particle board with decorative lamination on both sides.

31.12

-

-

... More
Removing of wooden glazed shutters of fume hood and shifting the same to store, complete in all respect as directed by Engineer-in-charge. (NS)

5.94

-

-

... More
Reomoving of existing regent shelves from worktop and shifting the same to store , complete in all respect as directed by Engineer-in-charge. (NS)

2.14

-

-

... More
Removing of existing cabinet shutter with chowkat by making recess in wall including remonving its fitting for re-use and shifting the same to store, complete in all respect as directed by Engineer-in-charge. (NS)

53.33

-

-

... More
Providing and fixing 19 mm thick BWR grade –II block board of required size fixed as shelves in cabinet including gutties, nails etc., complete in all respect

25.26

-

-

... More
Providing and fixing 15 mm to 18 mm thick Z-Black granite stone (polished) on work top including matching grains laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete (NS)

53.32

-

-

... More
Chamfering of Z-black granite stone fixed on worktop to required shape, complete in all respects as directed by Engineer-in-Charge (NS)

107.41

-

-

... More
Providing and fixing vitrified tiles of size 600 mm x 600 mm of approved make in flooring, laid in any pattern as specified over base of adhesive of reputed brands such as Pidilite, Laticrete, Ferrouscrete & Valendure as per IS specification 15477-2004 and jointed with white cement slury mixed with pigment to match the shade of tiles including tacking (making rough) the existing flooring, complete in all respect. (NS) Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, JOHNSONS, RAK, ORIENT BELL & SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this

112.7

-

-

... More
Providing and fixing wall cabinet of size 16’-0’’ long 2'-3" high and 1'-0" deep consisting of following:- (NS) (i) 19mm thick BWR Grade-II block board (ISI mark) of approved make having three horizontal pieces (one at top, one at Centre and one at bottom) vertical pieces @ 2'-0" c/c for making compartments (each fof size 2'-0" x 2'-3"). Outer face of the cabinet except back finished with1mm thick plastic laminated sheet (ISI mark) of approved make, shade & colour and inner side of cabinet finished with primer & painting. (ii) 6mm thick plywood BWR Grade-II (ISI mark) of approved make on back of cabinet. (iii) 30mm thick openable shutters in all compartments (each of size 2'-0"x 2'-3") consisting of 4mm thick glass in wooden style frame of commercial hard wood such as hollock, champ, chikrasy & chaplash. (iv) Wooden beading of commercial hard wood such as hollock, champ, chikrasy & chaplash etc. of size 0'- 3/4" & 0'-1/2" on all edges. (v) Angle iron 1'-6" long (at bottom of rack/cabinet) of size 25mmx25mmx5mm @ 4'-0" c/c embedded in cement concrete 1:2:4 blocks after making khudas in wall and MS flat at top of cabinet @ 4'-0" c/c of size 25mmx6mm. Including cost of locking arrangements in all compartments, gutties, rawl plugs, nails, screws, piano hinges, primer, paint, etc., complete in all respect as per architectual drawing and design.

2

-

-

... More
Providing and fixing 1mm thick plastic laminated sheet of approved make (Century, Green, Duro), shade and colour fixed on regent shelves with adhesive, complete in all respect as directed by Engineer-in-charge. (NS)

16.08

-

-

... More
Providing and fixing 6mm thick HPL Sheet Strips of 4’’ width for worktop face including adhesive etc., complete in all respect as directed by Engineer-in-charge. (NS)

8.45

-

-

... More
Providing and fixing 3’’ long hasps and staples of aluminium with necessary screws etc. for aluminium shutter under worktop, complete in all respect as directed by Engineer-in-charge. (NS)

77

-

-

... More
Providing & fixsing 3’’ long aluminium handles with necessary screws etc. for aluminum shutter under worktop, ccomplete in all respect as directed by Engineer-in-charge. (NS)

133

-

-

... More
Providing & fixsing 4’’ long aluminium T-bolt with necessary screws etc. for aluminum shutter under worktop, complete in all respect as directed by Engineer-in-charge. (NS)

77

-

-

... More
Tacking (making rough) the exposed reinforced cement concrete surface for cement plaster (horizontal and vertical surface) including removing of loose concrete, disposing off the malba and cleaning the surface etc., complete in all respect as directed by Engineer-in-Charge (NS)

14.68

-

-

... More
Providing and applying two coats of Dr. Fixit Pidicrete URP – SBR Latex (Pidilite make) solution made of URP + cement in the proportion of 1:1.5 (as recommended by the manufacturer) on deteriorated concrete surfaces of slab and columns, complete in all respects as directed by the Engineer-in-Charge (NS)

14.68

-

-

... More
Providing and applying 20 mm thick cement plaster in two coats (Ist layer 10 mm thick with cement coarse sand plaster 1:3 and final layer of cement plaster 1:3 with fine sand) at all height on horizontal/vertical surfaces., complete in all respect as directed by the Engineer-in-Charge (NS)

14.68

-

-

... More
PH work item 41 to 75 Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in first storey upto 4 metres above plinth level (HSR 10.59}

1.17

-

-

... More
Labour for laying, jointing, fixing and testing G.I./P.V.C./W.I. pipe lines and specials tees, bends, sockets elbows etc. inside building and testing etc. complete including cutting threading. {HSR 28.18(b)} INCLUDING COST OF SPECIALS (i) 15 mm internal diameter of pipe line

22.86

-

-

... More
(ii) 20 mm internal diameter of pipe line

28.95

-

-

... More
(iii) 25 mm internal diameter of pipe line

17.68

-

-

... More
(iii) 40 mm internal diameter of pipe line

19.5

-

-

... More
Labour for laying, jointing, fixing and testing G.I./P.V.C./W.I. pipe lines and specials tees, bends, sockets, elbows etc. in trenches in the ground, cutting, threading and testing etc., complete. {HSR 28.19} (h) 80 mm internal diameter of pipeline

59.13

-

-

... More
(i) 100 mm internal diameter of pipe line

9.14

-

-

... More
Extra for fixing and jointing union couplings in G.I and W.I pipe lines. {HSR 28.21} (b) 20 mm internal diameter

2

-

-

... More
(c) 25 mm internal diameter

2

-

-

... More
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. (HSR 28.24) (a) 11.43 cm thickness of walls

13

-

-

... More
(b) 22.86 cm thickness wall

3

-

-

... More
Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including repointing, replastering, replacing bitumen and colour or white washing where required. {HSR 28.26(b)} (b) 115 mm thickness of roof of floor

12

-

-

... More
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I pipelines laid in the ground or inside buildings including cartage from divisional stores or nearest railway station to site of works. {HSR 28.29} (b) 20 mm internal diameter

1

-

-

... More
(c) 25 mm internal diameter

1

-

-

... More
Making connection with the existing G.I branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site. (HSR 28.34)

2

-

-

... More
Constructing brick masonry inspection chambers sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/C.C. topping. 50 mm thick with 455 mm x 455 mm/ 455 mm x 610 mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I specification painted with 3 coats of black bitumastic superior paint complete as per standard design. (HSR 29.84) (c) size 600 mm x 900 mm inside ( with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg. With R.C.C. slab)

1

-

-

... More
Providing and fixing in position best Indian make vitreous chinaware sinks with complete fittings as fully described in item no. 30.51 above (HSR 30.52) WHITE (a) 600 mmx450mmx200mm

11

-

-

... More
Providing and fixing 40mm G.I waste pipe embedded in walls or lead waste pipe weighing 4.46 kg/ metre and 3.0 mm thick up to floor level as required by the Engineer-in-charge including cost of union and plumber joint. (HSR 30.62)

11

-

-

... More
Providing and fixing 15mm C.P brass laboratory cock swan neck of best quality ( to the approval of the Engineer-in-charge) (c) three way (HSR 30.78)

11

-

-

... More
Cutting chase in brick walls in cement or in floor for embedding G.I. or H.C.I. pipe lines and making good the same to its original condition {HSR 30.95(a) (a)size 75 mm X 75 mm

51.81

-

-

... More
Supply of G.I. pipe ‘B’ class ISI marked of ‘Ravindra’/ ‘Jindal’/ ‘Parkash ( Surya)’/BST make {NS) (a) 15 mm internal dia

22.86

-

-

... More
(b) 20 mm internal dia

28.95

-

-

... More
(c) 25 mm internal dia

17.68

-

-

... More
Supply of G.I. Union couplings of Unik / Unco make {NS} (b) 20 mm internal dia

2

-

-

... More
(c) 25 mm internal dia

2

-

-

... More
Supply of G.M. Peet valve (heavy type) of DRP/Leader/Bajaj make ISI marked. {NS} (b) 20 mm internal dia

1

-

-

... More
(c) 25 mm internal dia

1

-

-

... More
Supply of PVC pipe 6 kg/cm² pressure of ISI marked of Prince / Supreme/Finolex/Skipper make (as approved by the Engineer-in-Charge). (NS) a) 3” i/dia size (90 mm o/d)

59.13

-

-

... More
b) 4” i/dia size (110 mm o/d)

9.14

-

-

... More
c) 1½” i/dia size (50 mm o/d)

19.5

-

-

... More
Providing and fixing PVC floor traps of 3" i/d outlet of Prince/Supreme/Skipper make complete in all respect. (NS)

11

-

-

... More
Providing and fixing PVC gully traps of 4" i/d size with PVC cover & frame of Prince/Supreme/Skipper make complete in all respect. (NS)

3

-

-

... More
Providing and fixing PVC Tee of 3" x 3" x 3 i/d size Prince/ Supreme/ Skipper make complete in all respect. (NS)

3

-

-

... More
Providing and fixing PVC Tee of 1½" x 1½" x 1½" i/d size Prince/ Supreme/ Skipper make complete in all respect. (NS)

6

-

-

... More
Providing and fixing PVC Cowl of 3" i/d size Prince/ Supreme/ Skipper make complete in all respect. (NS)

3

-

-

... More
EI work item 76 to 103 MINIATURE CIRCUIT BREAKER AND ISOLATOR:(HSR 31.17) Supply and erection of miniature circuit breaker/isolator 240/415 V in the existing distribution board including making necessary connections (a) Miniature Circuit Breakers of 9 K.A. breaking capacity (ii)6-32 amp. SP MCB

20

-

-

... More
(ii) 32 amp. SPN MCB

4

-

-

... More
(iii) 63 amp. TPN MCB

1

-

-

... More
PIPE LAYING: Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required :-(HSR 31.21) (xv) Heavy gauge welded conduit pipe 20 mm dia 1.60 mm thickness on surface

90

-

-

... More
(xxii) Heavy gauge welded conduit pipe 25 mm dia 1.60 mm thickness on flushed

80

-

-

... More
Miscellaneous (HSR 31.35) (i) Supply of M.S. Pipe (B-Class) for suspension rod of ceiling fan including threading if required. (a) 15mm dia

10

-

-

... More
S/E of PVC unsheathed copper conductor cable single core 1100 volt grade in pipe of suitable size excluding cost and erection of pipe (HSR 31.40) (i) Size 1.5 sqmm(3/0.81mm)

1000

-

-

... More
(ii) Size 2.5 sqmm(3/1.05mm)

800

-

-

... More
(iii)Size 4 sqmm(7/0.85mm)

300

-

-

... More
S/E of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs etc. Recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer-in-charge of the work (HSR 31.41) (v)4-way, TP&N (Horizontal) (8+12)

1

-

-

... More
(vii)12way, TP&N (Horizontal) (8+36)

2

-

-

... More
Pdg. and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 31.56) 10 amp. 1 way switch

49

-

-

... More
20 amp.switch

65

-

-

... More
10 amp. Socket

14

-

-

... More
16 amp. socket

65

-

-

... More
Fan regulator

10

-

-

... More
Blinking plate

10

-

-

... More
Pdg. and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. (HSR 31.57) 3 Modules

10

-

-

... More
4 Modules

1

-

-

... More
6 Modules

32

-

-

... More
8 Modules

1

-

-

... More
12 Modules

4

-

-

... More
Supply, installation testing and commissioning of wall/free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2mm thick CRCA sheet, required hardware 3mm thick Bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of Zinc/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/switch wear. Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar Bakelite sheet 3mm thick for separately cable alley to BBC from switch chamber extended solid copper bars upto cable alleys shall provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wiring (copper) and fuse protection (Only outer area on all sides shall be measured) (HSR 31.63)

1

-

-

... More
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod and regulator etc. wih rating 5 star {NS} i) 1200mm sweep. Make: Usha, Orient, Crompton.

2

-

-

... More
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod and regulator etc. wih rating 5 star {NS} i) 1400mm sweep. Make: Usha, Orient, Crompton.

8

-

-

... More
S/E of recessed type ≤42 Watt full window glare free opal diffuse LED Panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 4600 or above in cool day light (5700K), Power factor ≥0.95, CRI (Ra) ≥80, LED Lamp efficiency ≥ 140 lm/w, Average life 50000 hours, complete with all accessories as required with connections. Make: Philips, Havells, Wipro, Bajaj (NS)

24

-

-

... More
S/E of Exhaust Fan size 380 mm (15") with necessary earthing arrangements of fan with shutter complete in all respects Size (15”) sweep (Heavy Duty) 900 RPM Make: Orient, Usha, Khaitan, Crompton (NS)

2

-

-

... More
S/I/T/C of push ON/OFF type 25 A modular type motor starter switch (white color) for AC's including the cost of petty material required to compete the job upto entire satisfaction of Engineer-in-charge. (NS) Make;- Schneider/Crabtree/Athena

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.