Chaudhary Charan Singh Haryana Agricultural University Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Chaudhary Charan Singh Haryana Agricultural University Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date26 Feb 2024
Closing DateCancelled
Tender Amount₹ 70,37,228 
Notes
Download

Costs

  • EMD

    ₹ 1,40,745
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
[10.9]Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling.

74.32

-

-

... More
[11.13.2]Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 2. 20 mm cement plaster

112.88

-

-

... More
[11.25.1]Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): 1. Flush / Ruled/ Struck or weathered pointing

822

-

-

... More
[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand)

112.88

-

-

... More
[11.6.1]15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand)

366.88

-

-

... More
[11.60]Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

513.18

-

-

... More
[11.61.1]White washing with lime to give an even shade : 1. New work (three or more coats)

381.78

-

-

... More
[11.65.1]Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer`s specification. 1. Two or more coats on new work

225.28

-

-

... More
[11.67.1]Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. Water thinnable cement primer

1427

-

-

... More
[11.68.3]Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works

457

-

-

... More
[11.76]Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete.

71.07

-

-

... More
[11.77]Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc.

71.07

-

-

... More
[11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade.

528

-

-

... More
[11.93.1]Finishing walls with water proofing cement paint of required shade : 1. New work (Two or more coats applied @ 3.84 kg/10 sqm)

636

-

-

... More
[11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

1106.67

-

-

... More
[12.10.2.1]Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 2.1. Kiln seasoned and chemically treated Hollock wood 35 mm thick

8.27

-

-

... More
[12.19.1.2.1]Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1.2.1. 35 mm thick shutters With ISI marked stainless steel butt hinges of required size Second class teak wood

17.65

-

-

... More
[12.37.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

9.41

-

-

... More
[13.29.1]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 1. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete

5400

-

-

... More
[13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

206

-

-

... More
[23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA

2

-

-

... More
[23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA

1

-

-

... More
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole

40

-

-

... More
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE

2

-

-

... More
[23.22.8.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.4. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 300 amp 415 volts

1

-

-

... More
[23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)

300

-

-

... More
[23.3.6.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm)

150

-

-

... More
[23.3.6.6]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.6. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm)

200

-

-

... More
[23.3.6.7]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.7. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 2.50 Sqmm(1.1.80mm)

100

-

-

... More
[23.3.6.9]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.9. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 3 run of Size 1.50 Sqmm(1/1.40mm)

100

-

-

... More
[23.4.1.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A

85

-

-

... More
[23.4.2.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 2.1. Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A

6

-

-

... More
[23.4.4.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.1. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A

20

-

-

... More
[23.4.5.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.1. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A

20

-

-

... More
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.

1000

-

-

... More
[23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data

10

-

-

... More
[23.8.10.4]FITTING AND ACCESSORIES 10.4. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules

10

-

-

... More
[23.8.10.6]FITTING AND ACCESSORIES 10.6. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 12 Modules

10

-

-

... More
[23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch

85

-

-

... More
[23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate

20

-

-

... More
[23.8.11.2]FITTING AND ACCESSORIES 11.2. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 2 way switch

6

-

-

... More
[23.8.11.3]FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch

20

-

-

... More
[23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket

20

-

-

... More
[23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket

20

-

-

... More
[23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt

7

-

-

... More
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.

2

-

-

... More
[24.1.11]EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.

30

-

-

... More
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.

2

-

-

... More
[24.2.6.4]LT CABLE 6.4. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 6 sqmm

50

-

-

... More
[24.4.8.5]STREET LIGHT 8.5. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 7 Metre Long pole with top dia 75 0mm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm

4

-

-

... More
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia

150

-

-

... More
[30.19]Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.

822

-

-

... More
[30.21]Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

225.35

-

-

... More
[30.25.1]Distempering with 1st quality acrylic distemper (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : 1. Old work (one or more coats)

760.85

-

-

... More
[30.28.1]Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 1. One or more coats on old work

277.4

-

-

... More
[4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil.

167

-

-

... More
[5.29.1]Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1. Of area 3 sq. metres and below

1

-

-

... More
[5.42]Dismantling cement conglomerate / terrazzo floors 25 mm to 50 mm manually/ by mechanical means and disposal of material within standard lead as per direction of Engineer- in-charge.

409.54

-

-

... More
[5.45]Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.

225.35

-

-

... More
[5.70]Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.

88.63

-

-

... More
[6.1.4]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 4. 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)

14.92

-

-

... More
[6.18]Reinforced cement concrete work in arches, arch ribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).

2.7

-

-

... More
[6.2.2]Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor four level, excluding the cost of centering, shuttering and finishing: 2. 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

19

-

-

... More
[6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level

2.9

-

-

... More
[6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level

2.71

-

-

... More
[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers

64

-

-

... More
[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level 6. Thermo-Mechanically Treated bars of grade Fe-500D or more.

100

-

-

... More
[6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more.

500

-

-

... More
[7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand)

141

-

-

... More
[8.27.2]Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work

33.22

-

-

... More
[9.46.3]Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 3. 12.5 mm thick tapered edge gypsum moisture resistant board

78.33

-

-

... More
[9.48]Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.

182.05

-

-

... More
NS items 76 to 124:- Supply and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing go same in existing panel including bending, cutting in required shape and size insulation with colour coding heat srinkable PVC insulation complete in all respect.

10

-

-

... More
Supply and erection of Under Ground Aluminium (Armoured) cable loose in existing pipe or trenches complete with necessary connections:- Size 4x120 sqmm.

50

-

-

... More
Supply installation testing and commissioning of wall free mounting dust and vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3 mm thick backlite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 caot of zine/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rising, the panel having PU/Neoprene rubber gasket of not less than 3 mm thickness separate dectachable gland plate MS base channel hinged door with inter locking arrangement fo equipment/switch wear as per details.

5

-

-

... More
Supplying, installation, testing and Commissioning of recessed type 42w Full window glare free opal Diffuser LED Panel of size 595X595mm suitable for Armstrong/POP/GB ceiling with MS Powder coated White Housing. Total system Lumen of 42W LED should be 5100 lumen or above in Cool day Light(5600K to 6500K), Power factor)0.95, CRI)80, LED lamp efficiency )100 Average life: =50000 hours. Complete with all accessories as required with connections. (Philips, Havells and GE )

28

-

-

... More
S/I/T/C of push ON/OFF type 25 A modular type motor starter switch (white colour) for AC`s including the cost of petty material required to complere the job upto entire satisfaction of Engineer In-Charge. Make:- Schnelder/Crabtree/Athena

5

-

-

... More
Supplying of surface/ wall mounted =36w integrated LED 4 feet fitting with Epoxy POwder coated white/ grey extruded aluminium channel housing for efficient heat dissipation total system lumen of 36 watt LED should be) 4000 lumen or above in Cool day Light(5700K to 6500K), Power factor)0.95, CRI)70, Average life: =50000 hours. Complete with all accessories as required with connections. (Philips, Havells and GE )

10

-

-

... More
Supply of propeller type AC ventilating fan (exhaust fan) with necessary earthing arrangements of fan with shutter complete in all respects Size 380mm sweep (Heavy Duty) 900 RPM Make: Orient, Usha, Khaitan, Crompton.

6

-

-

... More
S/E of underground cable loose in existing pipe or trenches complete with necessary connectons :-16sqmm 2 Core Cable

150

-

-

... More
S/E of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Cable Size 2.5 sqmm (3/0.81)

400

-

-

... More
S/E of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. i ) Cable Size 1.5 sqmm (3/0.81)

700

-

-

... More
S/E of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. i ) Cable Size 6 sqmm (3/0.81)

100

-

-

... More
S/E of Wall mounting industrial air circulator fan 600mm sweep , 1440RPM , 180watt , air delivery 270 mm and performance conforms to IS 2997-1964 standards.USHA/Havells

7

-

-

... More
S/E of LED Street Light of system voltage = 70/72watt IP66 Multiple LED with Lens optics and pressure die-cast aluminium housing for effective thermal management. Total system lumen = 8400 lumen LED should be 6500 or above in cool day light 5700K Lumen efficency = 120 lm/w. Power Factor ).95 average life )50000 hrs with connections complete Make Philiphs , Havell`s , Bajaj ,

8

-

-

... More
S/E of Double Arm bracket 1.5mtr Long 40mm dia G.I bracket with suitable seelve as per pole top dia galvanised with all petty material required to complete the job for satisfaction of Enginneer in charge.

4

-

-

... More
S/E of LED Type 250 Watt Flood Light outdoor type IP 65 die cast aluminium housing 5700 to 6500K Power factor )0.95, CRI (Ra) )80, LED lamp efficiency =110 lm/w, Average life )50000hours, complete with all accessories as required with connections. (Industrial) Make Havells , Philiphs

5

-

-

... More
S/E of AC ceiling fan capacitor type complete with shackle, 300 mm down rod and regulator. {NS} (i) 1400 mm sweep, Make:- Orient, Crompton

5

-

-

... More
Providing and fixingof 8.30 mm thick wooden laminate flooring of Vista make (shade VFF-106-Java Teak) laid over existing cement concrete flooring consisting of following:- Laying polythene sheet on existing concrete flooring, 4 mm thick foam placed on existing flooring site requirement. Wooden reducer profile at stepping of floor at entrance and towards press gallery portion. Removing and reflexing of existing wooden skirting adjoining stage before laying the floor, including cost of gutties, nails, screws etc. complete in all respect as directed by Engineering In-Charge.

16.72

-

-

... More
Providing and fixing 12 mm thick toughened glass of AIS/Modi/Guard/Saint Gobion make duly toughened by standarized plant with required holes and cut out for open-able door shutter including providing and fixing top and bottom pivot, complete in all respect as directed by Engineer-in charge. (door, handle, floor machine etc. to be paid separately).

6

-

-

... More
Providing and fixing glass shutter accessories i.e. glass door package with lock (floor machine) of Dorma make (Model XL-C4001) including cost of nuts, screws etc. complete in all respect

1

-

-

... More
Providing and fixing Glass Accessories i.e. handle of size 600 mm x 30 mm of DORMA make (Model XL-C-3004 ) including cost of stainless steel screws etc. complete in all respect as directed by Engineer-In-charge.

2

-

-

... More
Providing and fixing 17 mm to 20 mm thick Coffee Brown (South) granite stone (polished) in flooring including matching grains laid in any pattern, in linear as well as curvlinear as specified over base of 20 mm thick cement coarse sand mortar 1:4 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete.

317

-

-

... More
Providing and fixing 17 mm to 20 mm thick Coffee Brown (South) granite stone (polished) in skirting including matching grains laid in any pattern, in linear as well as curvlinear as specified over base of 12 mm thick cement coarse sand mortar 1:4 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete.

57

-

-

... More
Removing of existing damaged wall paneling with frame work and shifting the dismantled material to store with a lead of 2 km, complete in all respect as directed by Engineer-In-Charge.

310

-

-

... More
Providing and fixing welded mesh of size 75 mm x 75 mm made of 6 mm dia mild steel bar wire fixed in angle iron frame (excluding cost of angle iron frame) including cutting, straightening welding etc., complete in all respect as directed by Engineer-In-Charge.

2780

-

-

... More
20 mm thick cement plaster 1:3 in two coats under ceiling at all height, Ist layer of 10 mm thik with cement coarse and 1:3 (1 cement : 3 coarse sand) with cement plaster (one cement : three coarse sand) and second layer 10 mm thick 1:3 (one cement : three fine sand), cmplete in all respect as directed by the Engineer-In-Charge.

58.45

-

-

... More
Tacking (making rough) the exposed reinforced cement concrete surface for cement plaster (horizontal and vertical surface) including removing of loose concrete, disposing of the malba and cleaning the surface etc., complete in all respect as directed by Engineer-in-Charge.

58.45

-

-

... More
VARIABLE REFRIGERANT Volume/ FLOW SYSTEM (With Heat Pump) :-Supply, installation, testing and commissioning of aircooled variable refrigerant flow modular type airconditioning system with R410a refrigerant suitable for 415±10%, 50 cycles.The unit shall consist of indoor and out door units with individual controller as per detail given in specifications and having following items : (These items are to be given in Indian rupees with custom duites, inland frt,clearance etc on Site basis)Modular type outdoor units equipped with highly efficient inverter type scroll compressors with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and Outdoor unit having COP at 100% load to be minimum 3.4 to 3.5. of following capacitites: Cost of R 410 A Gas should be inclusive The outdoor unit should include all loading, unloading, transportation, power cabling/wiring from near the indoor and outdoor units respectively.The Vendor should considere the deration on ODU selection as per New Delhi Ambient conditions.Outdoor Units-Heat Pump , Fully Gas Charged (Make York, Trane, Fujitsu General) including cordless remote and Y joints VRV : 26 HP ODU

1

-

-

... More
Ducted Type indoor unit - VRV Supply, installation, testing and commissioning of Ducted Type indoor unit with corded remote controller.Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete. 2500 CFM / 7.5 TR

3

-

-

... More
Touch screen controller for indoor units controller - VRV Supply, installation, testing and commissioning of LED Display Type Centralized Controller (Which can control 364 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls.

1

-

-

... More
Supply, installation, testing and commissioning of imported refrigerant Y- joints/ headers.

2

-

-

... More
Inline fan Supply,installation,testing and commissioning of Circular Inline fan of the following capacity of approved make and specification. 500 CFM , 10-12 mm static pr. with single phase motor

3

-

-

... More
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. .Mandev, Totaline, Mexflow, Rajco 34.9 mm OD

10

-

-

... More
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. .Mandev, Totaline, Mexflow, Rajco 28.6 mm OD

10

-

-

... More
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. .Mandev, Totaline, Mexflow, Rajco 22.2 mm OD

30

-

-

... More
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. .Mandev, Totaline, Mexflow, Rajco 19.1 mm OD

20

-

-

... More
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. .Mandev, Totaline, Mexflow, Rajco 12.7 mm OD

20

-

-

... More
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. .Mandev, Totaline, Mexflow, Rajco 9.5 mm OD

30

-

-

... More
Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1.5 Square Meterm Cu between indoor unit and out door unit and indoor units and its remote controller.Belton Cable,Lapp, KEI , Polycab

100

-

-

... More
Providing and fixing and in position the following PVC pipes for condensate drain duly insulated with kinny foam and vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the indoor units upto the main header in the shaft dor vertical risers)Suprime, Polypack 25 mm dia

20

-

-

... More
Providing and fixing and in position the following PVC pipes for condensate drain duly insulated with kinny foam and vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the indoor units upto the main header in the shaft dor vertical risers)Suprime, Polypack 32 mm dia

25

-

-

... More
AIR DISTRIBUTION SYSTEM :- Supply,Fabrication , Installation and testing of sheet metal ducts in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces.( Make TATA, JINDAL, SAIL)Site Fabricated Duct 0.63mm (24 gauge) GSS

130

-

-

... More
Supplying, installing, testing and balancing of aluminium supply/return air grills of various sizes. Each grill shall be with fixed horizontal front bar at Zero/15 Deg deflection through the collar and register. Aluminium Exh./return air grilles without damper.

2

-

-

... More
Supplying, installing, testing and balancing of aluminium supply/return air grills of various sizes. Each grill shall be with fixed horizontal front bar at Zero/15 Deg deflection through the collar and register. Aluminium Return air Diffuser without damper.

1

-

-

... More
Supplying, installing, testing and balancing of aluminium supply/return air grills of various sizes. Each grill shall be with fixed horizontal front bar at Zero/15 Deg deflection through the collar and register. Al Volume control dampers for Diffusers and supply air collar of Linear Grille

2

-

-

... More
MECHANICAL INSULATION DUCT LINE ACOUSTIC TREATMENT `Supply and Application of acoustic lining within the supply air duct Fiber Glass wool of 32Kg./m³ density). as per specifications and drawings. 25mm thick (For Duct)

20

-

-

... More
SITC of Thermal insulation material for Duct insulation shall be closed cell cross linked polyethylene foam. Thermal conductivity of the insulation material shall not exceed 0.032 W/moK at an average temperature of 25oC. Density of the material shall be 25-30 Kg/m3. The product shall have temperature range of –40 oC to 105oC. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6: 1989 for fire propagation test and as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability as per DIN 52615 shall not exceed 0.15ng/Pa.Sec.m. 9 MM Thick (Make suprime, Aflex, Kflex)

115

-

-

... More
ASSOCIATED ELECTRICAL WORKS :- Supply and Erection of 125A, TPN ELCB with 18KA breaking capacity ODU Panel Described as above/As per Manufacturer ODU Configuration.

1

-

-

... More
Power Cabling and Earthing: Supply, installation, testing and commisioning of LPCB approved mineral insulated copper conductor cables, construction as per BSEN 60702-1:2002 suitable for withstanding 950 deg under fire conditions as per BS 6387 CWZ and 850 deg under fire conditions on one single sample as per BSEN 50200. Cable should be manufactured with seamless copper tube and should be HFLS sheathed. (Tagging to be provided with aluminium strips on both the ends as approved). 4Cx16 Square Meterm

50

-

-

... More
Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches:- 120 sq mm 4Core cable (armoured)

200

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.