Chaudhary Charan Singh Haryana Agricultural University Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Chaudhary Charan Singh Haryana Agricultural University Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date19 May 2022
Closing Date6 Jun 2022
Tender Amount₹ 7,32,82,730 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

  • EMD

    ₹ 12,40,000
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (HSR 5.70)

50

-

-

... More
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: With common burnt clay non-modular brick tile of class designation 10 (HSR 9.11.1) Note:- Excluding the element of mud and brick tiles:- Mud and brick tiles of recovered from demonisation shall be supplied free of cost to agency for re-used.

2339

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR 9.18)

30

-

-

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing periMeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and30 mm long, the periMeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of periMeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charae but excludina the cost of painting with 12.5 mm thick tapered edge gypsum moisture resistant board (HSR 9.46.3)

217

-

-

... More
Providing and Fixing 15 mm thick densifled tegular edged eco friendly light weight calcium silicate false celling tiles of approved texlure of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm interval and laying 15 mm thick densifled edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixlures, smoke detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ·r, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. (HSR 9.48) Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, noncombustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/mK.

1957

-

-

... More
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of sluny of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. (HSR 28.16)

2339

-

-

... More
Flush pointing with cement mortar 1: 3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for prefixed flat tile bricks on top of mud phaska: With F.P.S. brick tiles (HSR 30.20.1)

2339

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade: Old work (One or more coat applied @ 0.90 litre/10 sqm). (HSR 30.37.2)

1406

-

-

... More
Collection of common burnt clay non-modular brick tile of class designation-10 at site of work including carriage, loading, unloading and stacking etc., complete in all respect. (NS)

23000

-

-

... More
Scraping of brick tiles of size 22.86cm x 11.43cm x 3.81cm in cement mortar, complete in all respect as directed by Engineer-In-charge. (NS)

70000

-

-

... More
Providing and fixing at all height false ceiling consisting of following:- FRAME WORK Consisting of aluminium tube frame of size 25 mm x 38.10 mm x 2 mm @ 2 feet c/c fixed in position by suspenders of MS flat of size 1½" x 3/16" @ 4 feet c/c and steel rawal plug of approved make nuts & bolts CEILING WORK Consisting of HPL sheet of 6 mm thick of Green, Century and Sundek make fixed over aluminium tube frame properly by means of screws, nails etc., proper opending for light fittings and also petty items such as sealent, tape, rawal plugs, nails, screws etc., complete in all respect as per drawing & design. (NS)

406

-

-

... More
Providing and fixing 6 mm thick High Pressure Laminated (HPL) sheets, at all height, of Green, Century Alstone or Sunderk of approved colour on wall face/column fixed on aluminium tube frame of size 25 mm x 38.10 mm x 2.00 mm @ of 2'-0" C/C (Horizontal/vertical) i/c cost of sealent, tape, rawl plugs, nails, plastic gutties, screws, cutting etc. complete in all respects as per architectural drawing & design. (NS)

25

-

-

... More
Providing and fixing 12mm thick toughened glass of AIS/Modi Guard/Saint Gobion make duly toughened by standardized plant for making the cabins of differenet size with required holes and cut outs in fixed partition & openable panels/leaf for fully glazed single leaf dioors including fixing of glass in partitions by using 3 mm to 6 mm wide silicon adhesive, complet in all respect as per architectural drawingand design or instruction of Engineering-In-Charge (top portion of glass partitions shall be fixed in false ceiling by making grooves of required size & bottom of glass shall be fixed in WCP. (The item of WCP shall be paid separately). (NS)

454

-

-

... More
Providing and fixing glass shutter accessories i.e. glass door package with lock (floor machine) of Dorma make (Model XL-C4001B), including cost of nuts, screws etc. complete in all respect. (NS)

10

-

-

... More
Providing and fixing glass shutter accessories i.e. handle of size 600mm x 30mm of Dorma make (Model XL-C3004) including cost of stainless steel screws etc. complete in all respect as directed by Engineer in charge. (NS)

20

-

-

... More
Providing and fixing fittings/accessories of DORMA make as given below. (i) Wall Connecting Profile (WCP) suitable for 12 mm thick glass (DORMA XL-C-4026-A-12mmS), including cost of screws etc. complete in all respect as directed by Engineer-In-Charge. (NS)

99

-

-

... More
Providing and fixing fittings/accessories of DORMA make i.e. patch fittings for over panel and sidelight Dorma XLC-4003 A, including cost of screws etc. complete in all respect as directed by Engineer-In-Charge. (NS)

8

-

-

... More
Providing and fixing fittings/accessories of DORMA make i.e. connector for overpanel and sidelight Dorma XLC-4004 A, including cost of screws etc. complete in all respect as directed by Engineer-In-Charge. (NS)

2

-

-

... More
Providing and fixing fittings/accessories of DORMA make as given below:- (i) Central connector Dorma 4006-A, including cost of nuts, screws etc. complete in all respect. (NS)

20

-

-

... More
Providing and fixing fittings/accessories of DORMA make as given below:- (ii) Corner connector Dorma 4007-A, including cost of nuts, screws etc. complete in all respect. (NS)

30

-

-

... More
Providing and fixing fittings/accessories of DORMA make as given below:- (iii) Quadruple connector Dorma 4009-A, including cost of nuts, screws etc. complete in all respect. (NS)

40

-

-

... More
Providing and fixing frosted lining film of approved make, shade and column fixed in positin on toughened glass including making design/pattern as per architectural drawing and design or as directed by Engineer-In-Charge. (NS)

121

-

-

... More
Cleaning at all height the stone surface and removing dirt, dust, bird dropping, grease, oil, algae, fungus, monkey beats, vegetable growth etc., including providing, applying and washing the surface with liquid Ammonia Chemical of 5% solution and other cehmical cleaning agent as approved by Archaeological Survey of India/Engineer-In-Charge, of approved braqnd and manufacturer, with the help of required scrubbers and also cleaning with machine operated water jet mixed with desired quantity of fine silica where ever required, without causing any scratching/damage to the stone surface and finally washing the surface with clean water with the help of pressure jet machine, complete in all respect, including taking all precautions to safeguard ventilators, windows, doors etc. by suitable covering so as to avoid any damage to the building/structure, complete in all respect as per direction of Engineer-In-Charge. (The rate is inclusive of all materials, labour, scafolding etc. involved). (NS)

754

-

-

... More
Electrical work 27 to 112:- Designing, Supply & erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 +(-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge.The rating should be at 1500 RPM. a) Diesel Engine b) Alternator c) Battery 24 v. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) Tools, standard panel g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT's) h) Metering set 60/5A/11 OV (Amp. Meter, Volt Meter) i) Overload protection for DC-1 No. j) Battery Charger 24V DC k)Copper bus bar of suitable size I) KWH meter 96 sqmm size m) Starting fuse button and key switch9on/off) n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, De control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge Make : Kirloskar Green , Cummins .i) DG Set 500KVA (HSR 20.89.14)

1

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE (HSR 23.22.5.3)

150

-

-

... More
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing (HSR 23.22.4.5)

15

-

-

... More
Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work PVC pipe of 25 mm dia. (HSR 23.7.6.2)

2000

-

-

... More
PVC Pipe of 32mm dia (HSR 23.7.6.3)

200

-

-

... More
PVC pipe of 40 mm dia. (HSR 23.7.6.4)

500

-

-

... More
Control Cabling Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 100 X 50 X2mm (HSR 23.23.6.1)

50

-

-

... More
MS perforated cable tray painted with powder coating 200 X 50 X2mm (HSR 23.23.6.2)

75

-

-

... More
MS perforated cable tray painted with powder coating 375 X 50 X2mm (HSR 23.23.6.3)

200

-

-

... More
MS perforated cable tray painted with powder coating 600 X 50 X2mm (HSR 23.23.6.4)

100

-

-

... More
Earthing Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. (HSR 24.1.3)

24

-

-

... More
Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode (HSR 24.1.5)

24

-

-

... More
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.(HSR 24.1.7)

240

-

-

... More
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.8)

500

-

-

... More
S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HOPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work DWC/HDPE pipe 63/50 mm outer dialinner dia (HSR 24.5.2.3)

400

-

-

... More
RCC FOUNDATIONS FOR DG SET Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/cum of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per OEM recommendations to provide levelled surface for placement of the DG set complete in all respects and as per directions of Engineer-in-charge (Size of foundation assumed = 5.0x1 .Bx1 .Om) Unit: per cum per cum 8637 Note: As size and dynamic load of DG sets vary from manufacturer to manufacturer, item of DG set foundation have been included on the basis of cubic contents of RCC. 125 KVA DG Set (HSR 24.7.4)

1

-

-

... More
Supply & Erection of Main L.T Synchronization Panel outdoor type double door type having 01 No. ACB 1600A FP EDO 50KA for 800KVA Transformer , 01 No. ACB 1000Amp FP EDO , 50KA for 500KVA DG Set , 01 No. FP Contactor 500Amp for 250KVA DG Set , 01 No. FP Contactor 300Amp for 125KVA & 01 No. ACB FP EDO 50KA 1600Amp for Outgoing Feeders , having PLC Based synchronization function for 1 No. Transformer & 03 Nos. DG Sets with all control accessories required to complete in all respect with 05 sets of Metering including R,Y,B LED's , Multifunction meters, CT's , control MCB on all incomers & outgoing Feeders complete and all control accessories to complete the system , 02 nos. MCCB FP 50KA 400Amp with ROM ,02 Nos. MCCB FP 50KA 250Amp with ROM switchgear Make L&T/ABB/Schneider with made out of 2mm thicK CRCA sheet duly powder coated with siemens grey paint with base frame of 75*40*6mm M.S channel with 2000 Amp Aluminium busbar TPN with 1.0 sqmm current carring capacity with heat shrinkable seelve.Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.i) IP 55 for ODU panel. All MCCB’s shall be provided with operating mechanism for door interlock.All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.Providing cable clamps / supports within distribution boards cable alley.Current density of aluminium shall be 1sq mm for 1.0 Amps for rated current of bus bars.Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirment. All meter shall be digital type. Current Transfomer shall be resin cast.All Panel Shall be BMS Compitable The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required in all respect with suitable size CC foundation as per size of L.T panel with 3 foot height from ground level .NOTE :- All Incomer of all Panel having under & over voltage protection on each incomer Make Newtech / M.K electric Services , Hisar. ( NS)

1

-

-

... More
Supply & Erection of L.T Panel outdoor type double door having 01 No. ACB FP EDO 1600Amp 50KA for incoming & 02 Nos. ACB 800A FP 50KA EDO M/P Based as outgoings for HVAC Panels 1 & 2 , 01 Nos. 630Amp MCCB 50KA FP with ROM , 01 Nos. MCCB 400Amp FP 50KA with ROM as Spare , 01 Nos. MCCB FP 250Amp 36KA with ROM 02 Nos. 100Amp MCCB 25KA with ROM all outgoings having ON LED with complete set of Metering including R,Y,B LED's , Multifunction meters, CT's , control MCB , complete on all incomers and all control accessories to complete the system switchgear Make L&T/ABB/Schneider with made out of 2mm thich CRCA sheet duly powder coated with siemens grey paint with base frame of 75*40*6mm M.S channel with 2000 Amp Aluminium busbar TPN with 1.0 sqmm current carring capacity with heat shrinkable seelve.Degree of protection for following type of distribution panel enclosureshall be as per IS:13947-1993.i) IP 55 for ODU panel. All ACB/MCCB’s shall be provided with operating mechanism for door interlock.All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.Providing cable clamps / supports within distribution boards cable alley.Current density of aluminium shall be 1sq mm for 1.0 Amps for rated current of bus bars.Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirment. All meter shall be digital type. Current Transfomer shall be resin cast.All Panel Shall be BMS Compitable The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required complete in all respect.with suitable size CC foundation as per size of L.T panel with 3 foot height from ground level NOTE :- All Incomer of all Panel having under & over voltage protection on each incomerMake Newtech / M.K electric Services , Hisar. (NS)

1

-

-

... More
Supply & Erection of Main HVAC Panel outdoor type double door having 01 No. ACB 800AMP 50KA EDO AS INCOMER & 09 Nos. MCCB TP 100Amp , 25KA with ROM complete set of Metering including R,Y,B LED's , Multifunction meters, CT's , control MCB on incomer & ON LED on each outgoing feeders complete and all control accessories to complete the system Make L&T/ABB/Schneider with made out of 2mm thich CRCA sheet duly powder coated with siemens grey paint with base frame of 75*40*6mm M.S channel with 1000 Amp Aluminium busbar TPN with 1.0 sqmm current carring capacity with heat shrinkable seelve.Degree of protection for following type of distribution panel enclosureshall be as per IS:13947-1993.i. IP 55 for ODU panel. All MCCB’s shall be provided with operating mechanism for door interlock.All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.Providing cable clamps / supports within distribution boards cable alley.Current density of aluminium shall be 1sq mm for 1.0 Amps for rated current of bus bars.Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirment. All meter shall be digital type. Current Transfomer shall be resin cast.All Panel Shall be BMS Compitable The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required.complete in all respect.with suitable size CC foundation as per size of L.T panel with 3 foot height from ground level NOTE :- All Incomer of all Panel having under & over voltage protection on each incomerMake Newtech / M.K electric Services , Hisar. (NS)

2

-

-

... More
Supply & laying of L.T 4 Core * 630 sqmm Al. Armoured cable in sand & brick 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect. CCI/Havells/ICL/Universal. (NS)

200

-

-

... More
Supply & laying of L.T 4 Core * 630 sqmm Al. Ar. cable in Loose in existing trench , cable tray , pipe etc. including suitable Al. Lugs , Glands , connections complete in all respect. CCI/Havells/ICL/Universal (NS)

800

-

-

... More
Supply & laying of L.T 4 Core * 400 sqmm Al. Armoured cable in sand & brick 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect. CCI/Havells/ICL/Universal (NS)

250

-

-

... More
Supply & laying of L.T 4 Core * 400 sqmm Al. Ar. cable in Loose in existing trench , cable tray , pipe etc. including suitable Al. Lugs , Glands , connections complete in all respect. CCI/Havells/ICL/Universal (NS)

700

-

-

... More
Supply & laying of L.T 4 Core * 50 sqmm Al. Ar. cable in Loose in existing trench , cable tray , pipe etc.including suitable Al. Lugs , Glands , connections complete in all respect. CCI/Havells/ICL/Universal ( NS)

1100

-

-

... More
Supply & laying of L.T 4 Core * 10 sqmm Al. Ar. cable in Loose in existing trench , cable tray , pipe etc.including suitable Al. Lugs , Glands , connections complete in all respect. CCI/Havells/ICL/Universal (NS)

700

-

-

... More
S/E of HDPE 6" pipe with trenchless boring of road by HDD machine for laying required size of HDPE pipe 6" with socket reducer as per dia of cable at the end of pipe to closed the end of pipe to avoid entering of sand in pipe and all petty material required to complete the job as per entire satisfaction of the EIC. (NS)

1000

-

-

... More
S/E of XLPE(E) 11 KV HT Al. Conductor ar. Cable ISI mark laid in 1Mtr below ground level and sand bricks with all labour and material i/c digging and reflling complete CCI/Havells/ICL/Universal I ) 50sqmm 3 core cable XLPE (NS)

60

-

-

... More
S/E of XLPE(E) 11 KV HT Al. Conductor ar. Cable ISI mark laid in existing pipe/trenches/surface with all labour and material i/c digging and reflling of trench req. To complete the job. CCI/Havells/ICL/Universal I ) 50sqmm 3 core cable XLPE. (NS)

60

-

-

... More
S/E of heat shrinkage type end termination kit outdoor type of suitable to accommodate 3 core 11 KV XLPE aluminum cable / ABC cable complete with all the kit contents including earth continuing connection along with 3 Nos crimpling type aluminum lugs of suitable capacity including making jointing etc. complete in all respectSuitable for 16 to 50 sqmm 3 core XLPE cable. (NS)

6

-

-

... More
Providing & fixing G.I. inerlocking fencing of size 3" x 3" or any other size made of 10 gauge wire fixed with RCC post by means of MS flat & amp; bolts / nuts (Items of MS flat and bolts / nuts shall be paid separately under HSR) including drilling holes in MS flatetc, complete in all respects as per architectural drawing and design. (NS)

600

-

-

... More
S/E of coarse aggregate for concrete or stone ballast from quarried stone of size 53mm to 22.4mm. (NS)

20

-

-

... More
Supply & Erection of HDPE pipe 75mm complete in all respect. (NS)

150

-

-

... More
Supply & Erection of Chaneel 100*50*6mm stand for Outdoor unit on roof for HVAC System with complete with painting , grounting in all respect. With all petty matyerial required to complete the job. (NS)

34

-

-

... More
Supply & Erection of Safety Equipment Kit for O/D type Substation including of Fire Cylinders Co2 type 4.5KG - 02 Nos. , Co2 Type 10Kg - 02 Nos. , Fire Stand with 12 Nos. Fire Bucket 9 Ltr capacity - 01 Set , Rubber Mats 11KV - 10 sqmtr , 11KV Hand Gloves - 02 Sets , Tool Kit-01 No. Make BOSCH / Taparia. (NS)

1

-

-

... More
RCC FOUNDATIONS FOR 800kva Transformer Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/cum of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per suitable design of manufacturer recommendations to provide levelled surface for placement of the transformer complete in all respects and as per directions of Engineer-in-charge. i) 800 KVA (NS)

1

-

-

... More
Supply , Erection , Testing , Commissioning of 11kV Outdoor 3 way extensible RMU (1 LBS & 2VCB) with Manual fixed LBS & VCB with SF6 Gas insulated Outdoor RMU Type Installation 8DJH ST RLLL Load Break Switches - 1 Nos. & Vacuum Circuit breaker - 3 No. Rated Voltage - 12kV , Rated power frequency withstand voltage - 28kV , Rated lightning impulse withstand voltage - 75kV , Rated current for Ring main feeder - 630A ,Rated current for VCB feeder - 630A , Rated short-time current - 20kA / 3 Sec ,Rated short making current - 50kA, Ambient temperature - (-5 degree Celsius to +55 degree Celsius) RMU type 8DJH ST RLLL Extensible (1xLBS + 2xVCB)Each including Enclosure IP54 outdoor Each Load break Switches with SF6 gas insulated includes SF6 three position switches with position ON-OFF-EARTH Manual Operated spring mechanism ON-OFF-EARTH Mechanical indicators for position ON-OFF-EARTH Mimic diagram at the front facia of RMU Socket for Capacitive Voltage Indicator Padlocking facility Each Vacuum Circuit Breaker with SF6 gas insualted includesManual VCB with position ON-OFF Manual Line disconnector with three position switches ON-OFF-EARTH Auxiliary switches 6 NO + 6 NC with wiring WIB1 Make Woodward/ C&S make Self powered relay for Overcurrent and earthfault protection 3 phase definite time over current and short-circuit protection with variable tripping times (ANSI 50/51), 3 phase over current protection with selectable inverse time characteristics and definite time short-circuit current element (ANSI 50/51), definite . LV Current transformer compatible with self powered relay for protection 100-200/1A Socket for Capacitive Voltage Indicator Padlocking facility Accessories with each RMU includes Operating handle , Right angled Cable boots Make Siemens (i) CC Solid Plinth / foundation for Outdoor VCB shall be as per design & specification of the manufacturer & the cost shall be included in the quoted rates ABB/Schneider (NS)

1

-

-

... More
Supply, installation, testing and commissioning of aircooled variable refrigerant flow modular type airconditioning system with R410a refrigerant suitable for 415±10%, 50 cycles.The unit shall consist of indoor and out door units with individual controller as per detail given in specifications and having following items : (These items are to be given in Indian rupees with custom duites, inland frt,clearance etc on Site basis)Modular type outdoor units equipped with highly efficient inverter type scroll compressors with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and Outdoor unit having COP at 100% load to be minimum 3.4 to 3.5. of following capacitites: Cost of R 410 A Gas should be inclusiveThe outdoor unit should include all loading, unloading, transportation, power cabling/wiring from near the indoor and outdoor units respectively.The Vendor should considere the deration on ODU selection as per New Delhi Ambient conditions.Outdoor Units-Heat Pump , Fully Gas Charged with Suitable Size Stand made of 100*50*6mm Channel Stand complete Make :- O'General, Trane , Mitshubshi Heavy , York ( VARIABLE REFRIGERANT Volume/ FLOW SYSTEM (With Heat Pump)VRV : 36 HP ODU. (NS)

17

-

-

... More
Ducted Type indoor unit - VRV Supply, installation, testing and commissioning of Ducted Type indoor unit with corded remote controller.Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete.i) 2500 CFM / 8.1 TR (NS)

15

-

-

... More
2200 CFM / 6.4 TR (NS)

3

-

-

... More
1700 CFM / 4.6 TR (NS)

6

-

-

... More
1380 CFM / 4.1 TR (NS)

7

-

-

... More
1200 CFM / 3.2 TR (NS)

4

-

-

... More
860 CFM / 2.6 TR (NS)

2

-

-

... More
Ceiling Hung Type indoor unit - VRV Supply, installation, testing and commissioning of Ceiling Hung type indoor unit with cordless remote controller.Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete.i) 1400 CFM / 4.1 TR (NS)

45

-

-

... More
1200 CFM / 3.2 TR (NS)

8

-

-

... More
860 CFM / 2.6 TR (NS)

2

-

-

... More
Cassette Type indoor unit - VRV Supply, installation, testing and commissioning of Cassette type indoor unit with cordless remote controller.Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete.i) 1400 CFM / 4.1 TR (NS)

1

-

-

... More
1200 CFM / 3.2 TR (NS)

6

-

-

... More
Wall Mounted Type indoor unit - VRVSupply, installation, testing and commissioning of Wall mounted type indoor unit with cordless remote controller.Fully Factory assembled,wired and tested Indoor Units as per specifications ans as required to make the system complete.i) 735 CFM / 2.1 TR (NS)

15

-

-

... More
580 CFM / 1.6 TR (NS)

1

-

-

... More
414 CFM / 1.3 TR (NS)

13

-

-

... More
360 CFM / 1.1 TR (NS)

8

-

-

... More
Touch screen controller for indoor units controller - VRV Supply, installation, testing and commissioning of LED Display Type Centralized Controller (Which can control 364 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls. (NS)

2

-

-

... More
Supply, installation, testing and commissioning of imported refrigerant Y- joints/ headers indoor & outdoor including all petty material required to complete the job in all respect. Make O-General. (NS)

119

-

-

... More
Inline fan:- Supply,installation,testing and commissioning of Circular Inline fan of the following capacity of approved make and specification.500 CFM , 10-12 mm static pr. with single phase motor. (NS)

8

-

-

... More
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with ( 19/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with hangers. .Mandev, Totaline, Mexflow, Parasmani i) 41.3 mm OD (NS)

170

-

-

... More
34.9 mm OD (NS)

90

-

-

... More
28.6 mm OD (NS)

180

-

-

... More
22.2 mm OD (NS)

150

-

-

... More
19.1 mm OD (NS)

410

-

-

... More
15.9 mm OD (NS)

690

-

-

... More
12.7 mm OD (NS)

455

-

-

... More
9.5 mm OD (NS)

660

-

-

... More
6.4 mm OD (NS)

125

-

-

... More
Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1.5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller.Make : LAPP/ Belden / Gerard . (NS)

2000

-

-

... More
Providing and fixing and in position the following PVC pipes for condensate drain duly insulated with kinny foam & vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the indoor units upto the main header in the haft dor vertical risers)Suprime, Polypack, Polycab, i) 25 mm dia (NS)

250

-

-

... More
32 mm dia (NS)

100

-

-

... More
40 mm dia (NS)

50

-

-

... More
AIR DISTRIBUTION SYSTEM Site Fabricated Duct Supply,Fabrication , Installation and testing of sheet metal ducts in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces.i) 0.63mm (24 gauge) GSS ( TATA / Jindal ) (NS)

1000

-

-

... More
0.80mm (22 gauge) GSS ( TATA / Jindal ) (NS)

300

-

-

... More
Supplying, installing, testing and balancing of aluminium supply/return air grills of various sizes. Each grill shall be with fixed horizontal front bar at Zero/15 Deg deflection through the collar and register.i) Aluminium Exh./return air grilles without damper. (NS)

20

-

-

... More
Aluminium Return air Diffuser without damper. (NS)

20

-

-

... More
Al Volume control dampers for Diffusers & supply air collar of Linear Grille (NS)

10

-

-

... More
GI Volume control dampers for ducts (NS)

2

-

-

... More
MECHANICAL INSULATION DUCT LINE ACOUSTIC TREATMENT 'Supply and Application of acoustic lining within the supply air duct Fiber Glass wool of 32kg./m³ density). as per specifications and drawings.i) 25mm thick (For Duct) (NS)

75

-

-

... More
SITC of Thermal insulation material for Duct insulation shall be closed cell cross linked polyethylene foam. Thermal conductivity of the insulation material shall not exceed 0.032 W/moK at an average temperature of 25oC. Density of the material shall be 25-30 Kg/m3. The product shall have temperature range of –40 oC to 105oC. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6: 1989 for fire propagation test and as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability as per DIN 52615 shall not exceed 0.15ng/Pa.Sec.m. i ) 9 MM Thick (NS)

1225

-

-

... More
ASSOCIATED ELECTRICAL WORKS Supply & Erection of 01 No. 125A, TPN MCCB with 18KA breaking capacity , ROM , Metering Set Outdoor Type Enclosure Double Door having arrangement of 02 Nos. ELCB TPN ( wiring Only ) including all petty material required to complete the job in all respect. ODU Panel Described as above/As per Manufacturer ODU Configuration with Suitable size Angle 50*50*6mm Angle stand on roof .. Make :- Newtech / M.k Electric , Hisar. (NS)

34

-

-

... More
Power Cabling and Earthing:Supply, installation, testing & commisioning of LPCB approved mineral insulated copper conductor cables, construction as per BSEN 60702-1:2002 suitable for withstanding 950 deg under fire conditions as per BS 6387 CWZ and 850 deg under fire conditions on one single sample as per BSEN 50200. Cable should be manufactured with seamless copper tube and should be HFLS sheathed. (Tagging to be provided with aluminium strips on both the ends as approved).i ) 4Cx10 Sqmm (NS)

100

-

-

... More
4Cx25 Sqmm (NS)

200

-

-

... More
Supply and erection double pole/Four pole Residual ELCB on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary onnections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. i ) FP ELCB 300ma sensitivity, 63 A ( NS )

34

-

-

... More
Supply, installation, testing, termination and commissioning of copper wiring including PVC Pipe 25mm with 3C x 2.5 Sqmm Copper for indoor units supply complete. ( NS ) Make Havells , RR Kable , KEI. (NS)

3000

-

-

... More
S/E of fancy pole 3 mtr. Long made out of cast iron base part and miled steel grooved pipe section and joined together by means of threaded joints alongwith a service window provided in the bottom part of the pole to accommodate a 6 amp. SP MCB and 30 amp. connector for mains connection. A cast aluminium embellishment shall be fitted to the grooved steel pole by grub screw fixing to enhance the decorative look of the pole. The pole shall be duly pre-treated by shot blasting process and painted in poly - urethane paint in approved colour shade having a minimum 300 salt spray hours quoting on the pole and should have minimum 90 micrones DFT including suitable size CC foundation as per company design. Pole Make: Twinkle, Homdec Lighting LED Specifications: LED should be ≤30 watt with cast aluminium housing diffuser translucent poly carbonate having quoting PU/Polyster LED should be ≤ 30 watt with separate driver placed integrally in luminaire housing. Driver should be of THD ≤ 10% and power factor above ≥0.95, External surge protection device of 10 KV should be provided. LED lumen should be ≥ 3600. The luminaire body shall be painted with exterior grade of poly - Urethane/polyster quoting in required colour shade. LED CCT should be 3000K ingress protection IP 65, power rating 230 Volts, AC 50 Hz.with suitable civil foundation etc. (NS) LED Make: Everlite/ MSL

50

-

-

... More
SITC of 800 KVA outdoor type non sealed three phase 50Hz 11/430/250 copper wound oil imeresed naturally cooled distribution transformer complete with fitting and accessories inclusive of first filling of oil and confirming to IS-1180/1989 (Part-1) level 2 ISI Mark with OLTC & amp. latest amendments BIS specifications complete in all respects. (NS) Make : Jaybee/Nucon/Centuary

1

-

-

... More
S/E of recessed type =42 watt full window glare free opal difffuse LED panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 5100 or above in cool day light (5600k to 6500k), Power factor 0.95, CRI (Ra) 80, LED lamp efficiency ≥140 lm/w, Average life 50000hours, complete with all accessories as required with connections. (Industrial) Make :- Havells , Bajaj. (NS)

260

-

-

... More
S/E of Surface /Recessed type 36 watt LED Light having 4000 Lumen size 4 feet long suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 36 watt LED should be 4000 or above in cool day light (5600k to 6500k), Power factor 0.95, CRI (Ra) 80, LED lamp efficiency ≥140 lm/w, Average life 50000hours, complete with all accessories as required with connections. (Industrial) Make :- Havells , Bajaj. (NS)

100

-

-

... More
De-commissioning , Shifting , Re - commissioning of 125KVA DG Set with disconnection of existing LT connections , earthing strips from DG Set and shift within university premises and re erect with connectioning Lt cables , earthing strips including correction of any harm during transportation , charging successfully complete in all respect entire cable network and any other contingent thereto complete in all respect and directions of Engineer-in-charge. (NS) 125KVA DG Set

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.