Chaudhary Charan Singh Haryana Agricultural University Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 22,000Document Cost
₹ 1,000Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_HRY_236270_1Bid Award Id
ViewTender No
3327-CTender Authority
Chaudhary Charan Singh Haryana Agricultural University ViewPurchaser Address
-Website
http://https://www.hau.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles above 25 mm and up to 40 mm (HSR 5.43.2)
4
-
-
... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead). (HSR 5.45)
101
-
-
... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (HSR 5.70)
27
-
-
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.16)
0.28
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
Lintels, beams, plinth beams, girders, bressumers and cantilevers (HSR 6.30.5)
2
-
-
... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc.complete in all respect above plinth level.
Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
Thermo-Mechanically Treated bars of grade Fe-500D or more (HSR 6.34.6)
20
-
-
... More
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat:
With common burnt clay non-modular brick tile of class designation 10 (Based on HSR 9.11.1)
Note:- Excluding the element of mud and brick tiles:- Mud and brick tiles of recovered from demonisation shall be supplied free of cost to agency for re-used.
348.5
-
-
... More
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)
12
-
-
... More
Providing and laying of conglomerate floor 40mm thick cement concrete topping 1 :2:4 (HSR 10.8)
12
-
-
... More
Providing a floating coat of 1.50 mm thick neat cement laid in one operation
to the topping. (HSR 10.14)
115
-
-
... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1 :4 (1 cement: 4 fine sand) (HSR 11.6.1)
101
-
-
... More
Pointing on brick work or brick flooring with cement mortar 1 :3 (1 cement : 3 fine sand): Flush / Ruled/ Struck or weathered pointing (HSR 11.25.1)
254
-
-
... More
Rough cast plaster up to 1 O m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 1 O mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1 :4 (1 cement : 4 coarse sand) and top layer 1 O mm cement plaster
1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement.
Ordinary cement finish using ordinary cement (HSR 11.32.1)
26
-
-
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (HSR 11.60)
335
-
-
... More
Distempering with 1st quality acrylic distemper (ready mixed) having voe content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.
Two or more coats on new work (HSR 11.65.1)
335
-
-
... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:
Water thinnable cement primer (HSR 11.67.1)
335
-
-
... More
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 11.76)
46
-
-
... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)
46
-
-
... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)
46
-
-
... More
Finishing walls with water proofing cement paint of required shade :
New work (Two or more coats applied@ 3.84 kg/10 sqm) (HSR 11.93.1)
239
-
-
... More
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright
Kiln seasoned and chemically treated Hollock wood (HSR 12.19.2.1.2)
28.25
-
-
... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (HSR 12.37.1)
19.3
-
-
... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S.
pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
Profile E
Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (HSR 13.3.3.2)
21.35
-
-
... More
Providing & fixing glass panes with putty and glazing clips in steel doors,
windows, clerestory windows, all complete with 4.0 mm thick glass panes (HSR 13.10.1)
5
-
-
... More
Flush pointing with cement mortar 1: 3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for prefixed flat tile bricks on top of mud phaska:
With modular brick tiles (HSR 30.20.2)
348
-
-
... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (HSR 30.21)
335
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade
One or more coats on old work (HSR 30.28.1)
160
-
-
... More
Taking (making rough) the exposed reinforced cement concrete surface for cement plaster (horizontal and vertical surface) including removing of loose concrete, disposing off the malba nd cleaning the surface etc. complete in all respect as directed by Engineer-in-charge. (NS)
34.3
-
-
... More
Providing and fixing marble strips of size 14 mm to 17 mm thick and 35 mm wide in cement concrete/ terrazzo flooring fixed in position, complete in all respects as per drawing and design or as directed by Engineer-in-Charge. (NS)
182
-
-
... More
Providing and laying 20 mm thick cement plaster 1:3 in two coats under ceiling at all height (1st layer of 10 mm thick with cement coarse sand plaster 1:3 and final layer of cement sand plaster 1:3) complete in all respect as directed by the Engineer-in-charge. (NS)
34.3
-
-
... More
Public health work 34 to 87:-
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:
All kinds of soil Pipes, cables etc, not exceeding 80 metre (HSR 4.16.1.1)
76.2
-
-
... More
Pipes, cables etc. exceeding 80 mm metre (HSR 4.16.1.2)
76.2
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level:
1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)
10.04
-
-
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: (HSR 6.14.1)
1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size)
1.4
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
Suspended floors, roofs, landings, balconies (HSR 6.30.3)
14.74
-
-
... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc.complete in all respect above plinth level.
Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
Thermo-Mechanically Treated bars of grade Fe-500D or more (HSR 6.34.6)
140
-
-
... More
Brick work with common burnt clay non-modular bricks of class designation 10 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.22.2)
2.62
-
-
... More
Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado/worktop/risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1 :3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. (HSR 10.51)
4.47
-
-
... More
Cement Concrete 1 :8:16 Flooring Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. (HSR 10.100.2)
5.73
-
-
... More
12 mm cement plaster of mix :
1 :4 (1 cement: 4 coarse sand) (HSR 11.8.1)
30.13
-
-
... More
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines
20 mm internal diameter (HSR 20.23.2)
5
-
-
... More
25 mm internal diameter (HSR 20.23.3)
5
-
-
... More
50 mm internal diameter (HSR 20.23.6)
1
-
-
... More
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required
11.43 cm thick wall (HSR 20.26.1)
10
-
-
... More
22.86 cm thick wall (HSR 20.26.2)
10
-
-
... More
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I. pipelines laid in the ground or inside buildings, including cartage from divisional stores or nearest railway station to site of works
20 mm internal diametre (HSR 20.31.2)
5
-
-
... More
25 mm internal diametre (HSR 20.31.3)
5
-
-
... More
50 mm internal diametre (HSR 20.31.6)
1
-
-
... More
Making connection with the existing G.I. branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site. (HSR 20.36)
5
-
-
... More
Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1 :5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benchingb 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neat cement R.C.C. 1 :2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design.
Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) (HSR 21.84.3)
5
-
-
... More
Extra for every 0.30 metre depth of Inspection chamber
600 mm x 900 mm inside (HSR 21.85.3)
3
-
-
... More
Providing salt glazed stone ware pipes grade 'A' in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 induding the cost of jointing materials as well as carriage, loading, unloading, stacking,
handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. (HSR 21.94.2)
150mm i/d
45.72
-
-
... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White vitreous chinaware Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (HSR 22.1.4)
5
-
-
... More
Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:
Kitchen sink with drain board 610x460 mm bowl depth 200 mm (HSR 22.10.2.2)
5
-
-
... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe
40 mm dia (HSR 22.14.2.2)
5
-
-
... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (HSR 22.15)
5
-
-
... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (HSR 22.22.1)
5
-
-
... More
Providing and fixing white vitreous chinaware pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required
W.C. pan with ISi marked white solid plastic seat and lid (HSR 22.23.1 )
5
-
-
... More
Providing and fixing 8 mm dia C.P.S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. (HSR 22.38)
5
-
-
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall 50 mm nominal outer dia Pipes (HSR 22.85.6)
45.72
-
-
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes (HSR 22.86.2)
155.45
-
-
... More
25 mm nominal outer dia Pipes (HSR 22.86.3)
53.34
-
-
... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
25 mm nominal bore (HSR 22.103.3)
5
-
-
... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
15 mm nominal bore (HSR 22.104.1)
10
-
-
... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore (HSR 22.106.1)
20
-
-
... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore (HSR 22.107.1)
10
-
-
... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore (HSR 22.108.1)
25
-
-
... More
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (HSR 22.109)
55
-
-
... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (HSR 22.181)
2500
-
-
... More
Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. C.P Brass
Two Way (HSR 22.212.1.2)
10
-
-
... More
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.
Single Socket Type B 110 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.2)
76.2
-
-
... More
90 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.3)
32
-
-
... More
Supply and fixing of PVC floor traps (Heavy duty) of 90 mm o/dia outlet of Prince /Supreme/Skipper make, complete in all respect. (NS)
20
-
-
... More
Supply and fixing of PVC gully traps (Heavy duty) of 100 mm dia size ( 4") with cover and frame of Prince/Supreme/skipper make complete in all respect. (NS)
10
-
-
... More
Supply of CPVC Union Couplings with brass internals of Prince/Supreme/Skipper make . (NS)
(a)20 mm dia
5
-
-
... More
(b) 25 mm dia
5
-
-
... More
(c) 50 mm dia
1
-
-
... More
Supply of CPVC Control valves with brass internal fittings, complete in all respect. (NS)
(i) For 20 mm nominal outer dia Pipes
5
-
-
... More
(ii) For 25 mm nominal outer dia Pipes
5
-
-
... More
(iii) For 50 mm nominal outer dia Pipes
1
-
-
... More
Providing and fixing PVC waste pipe 40 mm i/dia size approximate 3’ long (Heavy duty) with coupler embedded in wall, complete in all respect. (NS)
5
-
-
... More
Providing and fixing looking mirror 5.0 mm thick mounted on asbestos sheet ground fixed in position by means of 4 Nos. C.P. brass screws and washers on rubber washers and rawl plugs embeded in wall or CP brass clamps with CP brass screws etc. complete in all respect.
Make:- Saint Gobin/MODI/ATUL (NS)
i) 3' x 2' size
30
-
-
... More
Providing and fixing CP Grating 5" dia size with anti cockroach lock of best quality, complete in all respect. (NS)
20
-
-
... More
Providing and fixing PVC specials of Prince/Supreme/Skipper make of following sizes. (NS)
Elbows
4'' i/dia
5
-
-
... More
Electrical work 88 to 115:-
COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS)
Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe
Group B (HSR 23.3.1.2)
64
-
-
... More
COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS)
Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. switch in 1.5
sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC
conduit pipe
Group B (HSR 23.3.2.2)
8
-
-
... More
COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS)
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5
sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including
providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS
Box etc complete as required
Group B (HSR 23.3.4.2)
20
-
-
... More
COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS)
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4
sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling ,
including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp
switch required MS Box etc complete as required
Group B (HSR 23.3.5.2)
8
-
-
... More
COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS)
Wiring main and sub mains in two single core for phase and neutral wire
and one single core for earth wire PVC insulated Copper conductor cable
1100 Volts grade in PVC Conduit etc as required
1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1)
350
-
-
... More
COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS)
Wiring main and sub mains in two single core for phase and neutral wire
and one single core for earth wire PVC insulated Copper conductor cable
1100 Volts grade in PVC Conduit etc as required
1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.2)
100
-
-
... More
COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS)
Wiring main and sub mains in two single core for phase and neutral wire
and one single core for earth wire PVC insulated Copper conductor cable
1100 Volts grade in PVC Conduit etc as required
2 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.6)
350
-
-
... More
COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS)
Wiring main and sub mains in two single core for phase and neutral wire
and one single core for earth wire PVC insulated Copper conductor cable
1100 Volts grade in PVC Conduit etc as required
2 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.7)
100
-
-
... More
Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends,
inspection box and all other material required to complete the job in all
respect up to the entire satisfaction of Engineer-in-Charge of work
MS pipe of 25 mm dia. (HSR 23.6.6.2)
300
-
-
... More
Providing and fixing Piano type accessories of approved make in existing
box and Bakelite sheet including fixing and making necessary connections,
complete in all respect.
Switch 5 amp. on existing sheet. (HSR 23.8.1.1)
84
-
-
... More
Providing and fixing Piano type accessories of approved make in existing
box and Bakelite sheet including fixing and making necessary connections,
complete in all respect.
Wall socket 5 amp on existing sheet. (HSR 23.8.1.2)
84
-
-
... More
Providing and fixing Piano type accessories of approved make in existing
box and Bakelite sheet including fixing and making necessary connections,
complete in all respect.
15 amp. switch on existing sheet. (HSR 23.8.1.3)
8
-
-
... More
Providing and fixing Piano type accessories of approved make in existing
box and Bakelite sheet including fixing and making necessary connections,
complete in all respect.
6 pin 15 multi socket on existing sheet (HSR 23.8.1.4)
8
-
-
... More
Providing and fixing Piano type accessories of approved make in existing
box and Bakelite sheet including fixing and making necessary connections,
complete in all respect.
Ceiling rose flush/surface type (HSR 23.8.1.5)
12
-
-
... More
Providing and fixing Piano type accessories of approved make in existing
box and Bakelite sheet including fixing and making necessary connections,
complete in all respect.
Call bell 220/230 volts musical type (HSR 23.8.1.6)
4
-
-
... More
Providing and fixing Piano type accessories of approved make in existing
box and Bakelite sheet including fixing and making necessary connections,
complete in all respect.
Bell push (HSR 23.8.1.9)
4
-
-
... More
Providing and fixing Piano type accessories of approved make in existing
box and Bakelite sheet including fixing and making necessary connections,
complete in all respect.
Bakelite angle/straight button holder large size (HSR 23.8.1.12)
48
-
-
... More
Providing and fixing Piano type accessories of approved make in existing
box and Bakelite sheet including fixing and making necessary connections,
complete in all respect.
Socket size rotary step type Electronic regulator for A.C. ceiling fan (HSR 23.8.1.13)
8
-
-
... More
Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet as below
75 mm x 75 mm x 60 mm deep M.S. box (HSR 23.8.3.1)
12
-
-
... More
Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet as below
100 mm x 100 mm x 60 mm deep M.S. boxx (HSR 23.8.3.2)
12
-
-
... More
Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet as below
180 mm X 100 mm X 60 mm deep M.S. Box (HSR 23.8.3.3)
24
-
-
... More
Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet as below
200 mm X 150 mm X 60 mm deep metal box (HSR 23.8.3.4)
12
-
-
... More
Supply and erection of double door sheet steel enclosure distribution board
suitable for MCBS and ELCBS etc. recessed in wall including bonding to
earth with all labour and material required to complete the job in all respect
up to the entire satisfaction of the Engineer-in-Charge of the work
SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) (HSR 23.22.4.2)
4
-
-
... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. To 32 amp. SP (HSR 23.22.5.1)
24
-
-
... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole (HSR 23.22.5.4)
4
-
-
... More
EARTHING AND LIGHTENING ARRESTOR
Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required . (HSR 24.1.1)
4
-
-
... More
Extra for using salt and charcoal / coke for pipe earth electrode as required. (HSR 24.1.2)
4
-
-
... More
Providing and laying earth connections from earth electrode with 4.00 mm G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11)
24
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements