If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Chaudhary Charan Singh Haryana Agricultural University Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date9 Aug 2024
Closing Date4 Sep 2024
Tender Amount₹ 87,76,082 
Notes
Download

Costs

  • EMD

    ₹ 1,75,600
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 1,180

Summary

Construction Of Training Hall At Kvk Kurukshetra

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
[10.62]Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

63.17

-

-

... More
[10.63.2]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm

216

-

-

... More
[10.67.2]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 2. Size of Tile 600x600 mm

8.2

-

-

... More
[10.70.2]Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 2. Size of Tile 600x600 mm

303.91

-

-

... More
[11.15]6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge.

33

-

-

... More
[11.26.1]Pointing on tile brick work with cement mortar 1:3 (1 cement : 3 fine sand): 1. Flush/ Ruled/ Struck or weathered pointing

320.31

-

-

... More
[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand)

435.52

-

-

... More
[11.58]Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete

461

-

-

... More
[11.6.1]15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand)

214

-

-

... More
[11.65.1]Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer`s specification. 1. Two or more coats on new work

406

-

-

... More
[11.67.1]Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. Water thinnable cement primer

461

-

-

... More
[11.68.3]Applying priming coat: 3. With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works

51.2

-

-

... More
[11.76]Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete.

46

-

-

... More
[11.77]Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc.

46

-

-

... More
[11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade.

97.2

-

-

... More
[11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

55.2

-

-

... More
[12.10.2.2]Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 2.2. Kiln seasoned and chemically treated Hollock wood 30 mm thick

2.14

-

-

... More
[12.102.1]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm

16

-

-

... More
[12.103.1]Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1. Single rubber stopper

4

-

-

... More
[12.104.2]Providing and fixing aluminium casement stays, ISI marked, anodised transparent or dyed to required colour and shade or powder coated or polyester powder coated, with necessary screws etc. complete. 2. Anodized (AC-15) Aluminium

20

-

-

... More
[12.114]Providing and fixing of roller blinds on windows complete with material and labour complete with push up and down arrangement as per approved design / colour and Engineer-in-charge.

36

-

-

... More
[12.157.1.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)

125

-

-

... More
[12.157.2.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)

125

-

-

... More
[12.158.2]Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 2. Pre-laminated particle board with decorative lamination on both sides

6.87

-

-

... More
[12.159.2]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 2. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

7.8

-

-

... More
[12.160.2]Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. 2. With brass cover plate minimum 1.25 mm thickness

2

-

-

... More
[12.162.1]Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. 1. 205 X 19 mm

8

-

-

... More
[12.19.2.1.2]Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 2.1.2. 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Kiln seasoned and chemically treated Hollock wood

2.14

-

-

... More
[12.37.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

23

-

-

... More
[12.50.1]Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 1. Fixed to steel windows by welding

539

-

-

... More
[12.60.1]Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : 1. 150 mm

2

-

-

... More
[12.98.1]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm

6

-

-

... More
[12.99.4]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 4. 150x10 mm

6

-

-

... More
[13.10.2]Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 2. 5.5 mm thick glass panes

37.9

-

-

... More
[13.27]Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

136.18

-

-

... More
[13.3.2.1]Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 2.1. Profile C Fixing with adjustable lugs with split end tail to each jamb

257

-

-

... More
[13.8.1]Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

121

-

-

... More
[20.23.2]Extra for fixing and jointing union couplings in G.I. and W.I. pipelines. 2. 20 mm internal diameter

2

-

-

... More
[20.23.3]Extra for fixing and jointing union couplings in G.I. and W.I. pipelines. 3. 25 mm internal diameter

4

-

-

... More
[20.26.1]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 1. 11.43 cm thick wall

4

-

-

... More
[20.31.3]Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I. pipelines laid in the ground or inside buildings, including cartage from divisional stores or nearest railway station to site of works. 3. 25 mm internal diametre

4

-

-

... More
[20.36]Making connection with the existing G.I. branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site.

1

-

-

... More
[21.84.3]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab)

3

-

-

... More
[21.85.3]Extra for every 0.30 metre depth of Inspection chamber 3. 600 mm x 900 mm inside

0.9

-

-

... More
[21.94.2]Providing salt glazed stone ware pipes grade ‘A’ in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 including the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. 2. 150mm i/d

30.48

-

-

... More
[22.103.3]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore

6

-

-

... More
[22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore

3

-

-

... More
[22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore

2

-

-

... More
[22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore

9

-

-

... More
[22.109]Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.

12

-

-

... More
[22.119.2]Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 2. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

2

-

-

... More
[22.123.1.2]Providing and fixing PTMT grating of approved quality and colour. 1.2. Circular type 125 mm nominal dia with 25 mm waste hole

8

-

-

... More
[22.127]Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.

3

-

-

... More
[22.15]Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer-in-charge.

6

-

-

... More
[22.16]Providing and fixing 40mm i/d G.I. waste pipe embedded in walls up to floor level including cost of union and plumber joint

6

-

-

... More
[22.181]Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

2000

-

-

... More
[22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

4

-

-

... More
[22.212.1.2]Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. 1.2. C.P Brass Two Way

6

-

-

... More
[22.22.1]Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1. White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

1

-

-

... More
[22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete

18.28

-

-

... More
[22.222.2.3]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete

12.19

-

-

... More
[22.26.4]Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 4. Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern

1

-

-

... More
[22.34]Providing and fixing floor mounted, white vitreous chinaware single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous chinaware cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.

2

-

-

... More
[22.38]Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.

2

-

-

... More
[22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass

2

-

-

... More
[22.50.1.2.1]Providing and fixing partitions for different type of urinals. 1.2.1. Vitreous Chinaware Partition plate. Large size 835mm x 355 mm White

3

-

-

... More
[22.86.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes

15.24

-

-

... More
[22.86.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes

33.52

-

-

... More
[22.87.5]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 5. 40 mm nominal outer dia Pipes

30.48

-

-

... More
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA

4

-

-

... More
[23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP

4

-

-

... More
[23.22.4.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing)

1

-

-

... More
[23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)

1

-

-

... More
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole

25

-

-

... More
[23.22.5.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.7. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs FOUR POLE

1

-

-

... More
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE

1

-

-

... More
[23.22.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 7. Supply and erection of blanking sheet in existing distribution board.

9

-

-

... More
[23.23.2.1]MISCELLANEOUS 2.1. Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia

16

-

-

... More
[23.23.8.1]MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire

200

-

-

... More
[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required

1000

-

-

... More
[23.3.6.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm)

30

-

-

... More
[23.4.1.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A

54

-

-

... More
[23.4.4.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.1. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A

22

-

-

... More
[23.4.5.1]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.1. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A

18

-

-

... More
[23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm)

100

-

-

... More
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.

500

-

-

... More
[23.7.6.4]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia.

50

-

-

... More
[23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data

18

-

-

... More
[23.8.11.10]FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate

10

-

-

... More
[23.8.11.11]FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type

8

-

-

... More
[23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt

16

-

-

... More
[23.8.11.8]FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type

2

-

-

... More
[23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.

16

-

-

... More
[24.1.11]EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.

20

-

-

... More
[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required.

20

-

-

... More
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.

2

-

-

... More
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.

2

-

-

... More
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.

20

-

-

... More
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.

20

-

-

... More
[24.2.2.2]LT CABLE 2.2. Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- 16 Sq mm to 35 sqmm 2 to 4 Core

150

-

-

... More
[24.2.2.3]LT CABLE 2.3. Laying of underground cable 0.75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- 50 Sq mm to 150 sqmm 2 to 4 Core

150

-

-

... More
[24.2.4.2]LT CABLE 4.2. Laying of underground cable in pipe /existing open/closed trench etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core

25

-

-

... More
[24.2.4.3]LT CABLE 4.3. Laying of underground cable in pipe /existing open/closed trench etc as required:- 50 Sq mm to 150 sqmm 2 to 4 Core

25

-

-

... More
[24.2.5.2]LT CABLE 5.2. Laying and fixing of cable on surface/ cable tray etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core

25

-

-

... More
[24.2.5.3]LT CABLE 5.3. Laying and fixing of cable on surface/ cable tray etc as required:- 50 Sq mm to 150 sqmm 2 to 4 Core

25

-

-

... More
[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core

4

-

-

... More
[24.2.8.5]LT CABLE 8.5. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 25 sqmm

8

-

-

... More
[24.2.8.7]LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm

8

-

-

... More
[24.4.3]STREET LIGHT 3. Supply and erection of 32mm dia metre 1.5 m long bracket (B-class) making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing of GI. bracket on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections.

4

-

-

... More
[4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil.

132.27

-

-

... More
[4.16.1.1]Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1.1. All kinds of soil Pipes, cables etc, not exceeding 80 mm dia.

30.48

-

-

... More
[4.16.1.2]Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1.2. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

30.48

-

-

... More
[6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

2.83

-

-

... More
[6.1.7]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)

21.6

-

-

... More
[6.10]Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.

21.55

-

-

... More
[6.12.1]20 mm thick cement plaster damp-proof course 1:3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded: 1. Vertical

20

-

-

... More
[6.12.2]20 mm thick cement plaster damp-proof course 1:3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded: 2. Horizontal

20

-

-

... More
[6.13]Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth.

47.65

-

-

... More
[6.14.1]Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)

35.61

-

-

... More
[6.15.1]Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)

15

-

-

... More
[6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

78.5

-

-

... More
[6.21]Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand(zone-III) : 3 graded stone aggregate 20mm nominal size).

3.34

-

-

... More
[6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete

26.48

-

-

... More
[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform

284.22

-

-

... More
[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers

157

-

-

... More
[6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts

95.78

-

-

... More
[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level 6. Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, weldedjoints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect for all heights/depths/storeys/basements etc. Note-Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.

18586

-

-

... More
[6.9.1]Providing and laying damp-proof course with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size) 1. 50 mm thick

21.55

-

-

... More
[7.21.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement mortar 1:6 (1 cement : 6 coarse sand)

63.07

-

-

... More
[7.27.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in foundations and plinth in : 2. cement mortar 1:4 (1 cement : 4 coarse sand)

2.09

-

-

... More
[7.28.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand)

27.22

-

-

... More
[7.39.2]Brick work with common burnt clay selected non-modular bricks of class designation 10.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand) 2. Above plinth level up to floor IV level

125

-

-

... More
[8.26.2.2]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shade Area of slab over 0.50 sqm

2.32

-

-

... More
[9.10.1]Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : 1. With residual type petroleum bitumen of grade VG -10

320.31

-

-

... More
[9.11.1]10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10

320.31

-

-

... More
[9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase

76

-

-

... More
[9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

12

-

-

... More
[9.46.3]Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 3. 12.5 mm thick tapered edge gypsum moisture resistant board

60

-

-

... More
[9.48]Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.

140

-

-

... More
[9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter

31.1

-

-

... More
[9.58.5.2]Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5° 110 mm bend

6

-

-

... More
[9.61]Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms.

6

-

-

... More
NS Items 146 to 203:- Earth filling under floors with dune sand (tiba sand)/ earth, brought from outside (any lead) in 15 cm layer including laying, dressing, watering, ramming, consolidating, excavation, carriage, loading, unloading and compensation etc. complete.

203.17

-

-

... More
Providing and fixing of PVC floor trap 3`` i/dia 90 mm o/dia outlet of Prince/ Supreme/ Skipper make, complete in all respect.

8

-

-

... More
Supply of CPVC union coupling with brass internal OF PRINCE / SUPREME/ SKIPPER MAKE 20 mm dia

2

-

-

... More
Supply of CPVC union coupling with brass internal OF PRINCE / SUPREME/ SKIPPER MAKE 25 mm dia

4

-

-

... More
Supply of CPVC control valve with brass internals of Prince/ Supreme/ Skipper make 25 mm dia

4

-

-

... More
Providing and fixing PVC wall paneling consisting of 7mm thick cactus make hollow PVC section, PVC U section beading of size 25 x 8 x 12 mm and PVC angle nosing of size 25 x 25 x 1.5 mm including cost of PVC gutties, screws, jointed with poly fix (instant glue) complete in all respect as per drawing or as directed by Engineer-in-charge.

41.62

-

-

... More
Providing and fixing CI grating over 100 mm dia rain water pipe, fixed in position, complete in all respects.

6

-

-

... More
Supply of PVC specials Elbow 110 mm 4`` i/dia, Prince/ Skipper/ Supreme make.

2

-

-

... More
Providing and fixing display board consisting of following:- i) 6 mm thick BWR grade-II plywood (ISI mark) of approved make fixed on back side. ii) 19 mm thick pinning board fixed on plywood iii) Blazer cloth of approved colour fixed on pinning board iv) wooden beading of commercial hardwood such as hollack, champ, chikrasy, chaples etc. of size 0`-1½`` x 0`-1``. v) Hooks made of MS flat of size 40 mm x 6 mm at top @ 4 feet C/C including cost of cutting, gutties, rawl plug, nails, screws, adhesive etc., complete in all respect as per drawing and design

3.9

-

-

... More
Supplying and fixing readymade white writing board of PRESKO make with delux frame or any other similar brand, fixed in position, including wooden gutties, nails and screws etc. complete in all respect as per drawing and design.

3

-

-

... More
Providing and fixing glass shutter accessories i.e. glass door package with lock (floor machine) of Dorma make (Model XL-C 4001) including cost of nuts, screws etc. complete in all respect.

2

-

-

... More
Providing and fixing glass shutter accessories i.e. handle of size 600 mm x 30 mm of Dorma make (Model XL-C3004 ) including cost of stainless steel screws etc. complete in all respect s directed by Engineer-in-charge.

4

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass of Saint Gobin/AIS/MODI/GUARD make dully toughened by standarized plant with required holes and cut out for open-able door shutter at all height including providing and fixing top and bottom pivot, fixed in position, complete in all respect as directed by Engineer-In charge. (Door handle, floor machine will be paid extra)

7.5

-

-

... More
Providing cushioned chairs without arm for Training Hall

1

-

-

... More
Providing and fixing digital metering equipment for LT cubical panel consisting of 96 mm x 96 mm x 0-500 V, meter with selector switch amp. meter (of required ration upto 600/5 amp) with selector switch and required C.Ts 3 Nos. A set of 3 No. phase indication lamps RYB LED

2

-

-

... More
Providing and fixing 6 mm thick high pressure laminated (HPL) sheets at all height of Green, Century Alstone or Sundek make of approved colour fixed on aluminium tube frame of size 25 mm x 38.10 mm x 2.00 mm @ of 2`-0` C/C on wall cladding including cutting, sealant, tape, rawl plugs, nails, screws etc. complete in all respect as per drawing and design or as directed by Engineer-In-charge

27

-

-

... More
Providing and fixing in position white Chinaware wash hand basin of Avior-R model of Hindware make size 59.50 x 42 x 15.5cm, complete in all respect Cat No. 91207

3

-

-

... More
Supply and fixing of PVC Gully Trap of 100 mm dia size 4’’ i/dia with cover and frame (Heavy duty) of PRINCE/ SUPREME/ SKIPPER make.

2

-

-

... More
Providing and fixing CP brass Swan Neck single line pillar cock (Hindware make) Cat No. F520002, complete in all respect

3

-

-

... More
S/E of AC ceiling fan capacitor type complete with shackle, 300 mm down rod and regulator. (i) 1400 mm sweep, Make:- Orient, Crompton

16

-

-

... More
SITC of push ON/OFF type 25 A modular type motor starter switch (white colour) for AC`s including the cost of petty material required to complete the job upto entire satisfaction of Engineer-In-charge Make: Schnelder/Crabtree/Athena

4

-

-

... More
Supply of propeller type AC ventilating fan (exhaust fan) with necessary earthing arrangments of fan with shutter complete in all respect Size 300 mm (12`) sweep Make:-Orient, Usha, Havells, Crompton

2

-

-

... More
S/E of surface /wall mounted (20watt LED 4 feet fitting with Epoxy Powder coated white/ Grey extruded aluminium channel housing for efficient heat dissipation. Total system lumen of 20watt LED should be )2200 or above in cool day light ( 5700K to 6500K ) PF ) 0.95 , CRI )80 , Avg. life )50000 hours complete with mounting bracket and accessories as required with connections Make Philips , Havells , wipro , Bajaj

6

-

-

... More
Supply and erection of LED street light of system voltage ( 70/72 watt IP 66 multiple LED with lens optics and pressure dia-cast aluminium housing for effective thermal management. Total system lumen (70 watt LED should be 8400 or above in cool day light 5700K lumen efficiency =110lm/w PF )0.95, CRI)70, Average life )50000 hours with connections, working hours 50000 hrs. complete in all accessories as required. Make:- Phillips/Havells/Wipro/Bajaj

4

-

-

... More
Supplying, installation, testing and Commissioning of recessed type 42w Full window glare free opal Diffuser LED Panel of size 595X595mm suitable for Armstrong/POP/GB ceiling with MS Powder coated White Housing. Total system Lumen of 42W LED should be 5100 lumen or above in Cool day Light(5600K to 6500K), Power factor)0.95, CRI)80, LED lamp efficiency)100 lm/w, Average life: )50000 hours. Complete with all accessories as required with connections. (Philips, Havells and GE )

28

-

-

... More
Providing and installing split type air conditioners, four star rating inverter type with copper coils 2.0 ton capacity plus 10% fitted with super tropical- DC PAM inverter return cooled rotary compressor operating on refrigerant R-32-A/410 suitable for wall mounting confirming to IS:1391 (part-2) 92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts,50 Hz single phase A.C supply having following specifications:- i) Cooling coil row- 3 Nos. ii) Air flow (CMH)-800 - 1450 cum/hr iii) Sound level (H/M/L)-41/38/34/25 iv) Louvers swing -3D plus 3D Auto etc. complete in all respect Make Ogeneral/ Mitsubishi (Heavy industries)

4

-

-

... More
Providing and installation of automatic voltage stablizer of Single Phase 5.00 KVA capacity copper would heavy duty 100 volt up of Logicstate/ Voltstar/ Bluestar/ V-guard make ISI marked complete in all respect

4

-

-

... More
Providing and fixing extra copper tubing/refrigerant pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. (NS) NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing and laying refrigerant pipe line of four metres length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing and laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring: suitable electric wiring and switch should be provided with in 4 metres of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 gauge (1 mm) (i) Liquid line :- 6.35mm (1/4`) (ii) Gas line:- 15.88mm(5/8`) 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit.

16

-

-

... More
Providing and fixing in position powder coated MS stand for outdoor units of air conditioners including suitable nuts and bolts etc. of nest quality complete in all respect.

4

-

-

... More
S/E of underground cable XLPE cable aluminium conductor armored. 25 sqmm 4 core cable(armoured)

200

-

-

... More
S/E of underground cable XLPE cable aluminium conductor armored. 50 sqmm 4 core cable(armoured)

200

-

-

... More
Supply installation testing and commissioning of wall free mounting dust and vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3 mm thick bake-lite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of zine/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rising, the panel having PU/Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement of equipment/switch wear as per details.

10

-

-

... More
Supplying and fixing of copper bus bar duly tinned by means of SMC / BMC type insulatter high tensile nuts and bolts spring washer fixing to same in existing pannel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation complete in all respect.

15

-

-

... More
Supply Installation testing and commissioning of 24 Port POE Access Switch with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Switch should offer Wire-Speed and Non-Blocking Switching with 24 10/100/1000 RJ45 PoE/PoE plus Ethernet ports and additional 4 SFP plus (1G/10G ) fiber based ports, Minimum 2 port Populated with 10G MMF,Access Switches should support non-blocking switching fabric capacity of minimum 88 Gbps and minimum line-rate forwarding capacity of 57 Mpps, Access switch should support minimum 16K MAC addresses and minimum 4K active VLANs, Access Switch should have stacking capability with minimum stacking bandwidth of 40Gbps and should support a minimum of 8 units in a stack. Minimum one meter Stacking cables should be included in supplied material, Access switch should support up to 8 hardware queues per port, Access Switch should support full Layer 2 features like STP, RSTP, LACP, ACL, QoS, IGMP v1/v2, Access Switch should support basic L3 features like IPv4 and IPv6 static routing, Layer 3/4 ACLs, ECMP, virtual interfaces and routed interfaces from day 1, Access Switch should be upgradable to support advance Layer 3 features like, RIPv1/v2, OSPF v2, OSPFv3, and HSRP/VRRP in future with an additional software license upgrade,Access Switch should support minimum 1K IPv4 routes, The Access Switch should support IPv6 management features like IPv6 ping, IPv6 trace route, IPv6 Telnet, IPv6 TACACS, IPv6 and IPv6 RADIUS, All Switches and Transceivers should be of same OEM make,Access switch should support minimum 4K ACL rules ACL per Switch, Access switch should support SNMP v1/v2/v3, SSH, NTP and web management, Access switch should have 1G of RAM and 2G of Flash Memory. MAKE : RUKUS/CISCO/HP

1

-

-

... More
CCTV:-Supply Installation testing and commissioning of 4MP IP Network Dome Camera with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Image Sensor : 1/3” 4 Megapixel Progressive scan CMOS sensor or better ,Effective Pixels : 2688(H)x1520(V)) or better , Electronic Shutter : Auto/Manual, 1/3(4)~1/100000s, Scanning System : Progressive , Mini. Illumination : 0.08Lux/F2.0(Color): 0Lux (IR on), S/N Ratio : More than 50dB , Min. IR LEDs Length =50m, Day/Night : Auto(ICR) / Color / B/W,Back Light Compensation : BLC / HLC / WDR(120DB) ,White Balance : Auto/Natural/Street Lamp/Outdoor/Manual ,Motion Detection : Off/On (4Zone, rectangle),Focal Length : 2.8mm,Angle of View : H: 104° ,V: 57° ,Video Compression : H.265 plus / H.265 ,Resolution : 4MP (2688x1520)/3MP(2304x1296)/ 2MP(1920× 1080)/720P(1280× 720),Frame Rate (3 Stream) : Main stream (4MP (1 ~ 25/30fps)) and Sub stream : D1(1 ~ 25/30fps)and Third Stream : 720P (1 ~ 25/10fps),Digital Zoom : 16x,Bit Rate : H.265: 14 ~ 9984Kbps,Network Ethernet : RJ-45 (10/100Base-T) ,Protocol : HTTP: HTTPs: TCP: ARP: RTSP: RTP: UDP: SMTP: FTP: DHCP: DNS: DDNS: PPPOE: IPv4/v6: QoS: UPnP:NTP: Bonjour: 802.1x: Multicast: ICMP: IGMP: SNMP,SD Card : Min 128GB SD card support,Power Supply : DC12V, PoE (802.3af),Working Environment : -30°C~ plus 60°C / Less than 95%RH (no condensation),Ingress Protection : IP67 ,Audio Interface : Built-in-Mic,Intelligence (IVS) : Tripwire, Intrusion, Object Abandoned/Missing ,Advanced Intelligent Functions : Face Detection MAKE : DAHUA/HONEYWELL/HYUNDAI

4

-

-

... More
Supply Installation testing and commissioning of Video Management Recorder with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Main Processor : Intel Quad-core Processor or better, Operating System :Embedded LINUX,IP Camera Input : 32 Channel or More, Two-way Talk : 1 Channel Input, 1 Channel Output/RCA, Interface : =2 HDMI (up to 3840 x 2160 , Different Source), =1 VGA, Compression : H.265/H.264, Resolution : 12MP, 8MP, 6MP, 5MP, 4MP, 3MP, 1080P, 1.3MP, 720P etc., Bandwidth : )320Mbps,Record Mode : Manual, Schedule (Regular, MD (Motion Detection), Alarm, Analytics), Holiday, Stop, Video Detection : Motion Detection/ Video Loss and Tampering/ Multiple VCA Event, Alarm input : =16 Channel, Relay Output : =8 Channel, Search Mode : Time /Date, Alarm, MD / Smart Search, Backup Mode : USB Device/Network/eSATA Device, Network Interface : 4 RJ-45 Ports (10/100/1000Mbps), Ethernet Port : 4 Ethernet Ports Joint Working or 4 Independent 1000Mbps Ethernet Ports, Network Function : HTTP, HTTPs, TCP/IP, IPv4/IPv6, UPnP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE,DDNS, FTP, Alarm Server, IP Search etc., Optical Fiber Interface : =2 Giga Optical Fiber Interface, User Access : =128 users, Smart Phone : iPhone, iPad, Android, Interoperability : ONVIF 2.4, CGI Conformant, Internal HDD : 16 SATA III Ports, Up to 8 TB capacity for each HDD, HDD Mode : Single, Raid 0/1/5/6/10, Support Global HDD Hot-spare, eSATA : 1 eSATA Port, SAS : 1 Mini SAS Port, for Storage Expansion,Front Cover : Support Hot-swap, USB : 4 USB Ports (2 USB 2.0 , 2 USB 3.0 ), RS232 : 1 Port, for PC Communication and Keyboard, RS485 : 1 Port, for PTZ Control, Power Supply,Redudant Power supply : Support, Operating Conditions : -10°C ~ plus 55°C, Certifications : CE,UL,FCC (NS) MAKE : DAHUA/HYUNDAI/HONEYWELL

1

-

-

... More
Supply Installation testing and commissioning of 6TB surveillance hard disk with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : WD-PURPLE/SEGATE

1

-

-

... More
Supply installation testing and commissioning of internet box with RJ-45 Jacks, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer-in-charge. Make: DLINK/AMP/Molex/Belden

6

-

-

... More
Supply Installation testing and commissioning of outdoor 4 x 4 box with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer-in-charge. Make: Stronger/ Molex/ Amp/ Dlink

4

-

-

... More
Supply Installation testing and commissioning of Category 6 Patch Cord 6.5 feet, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. MAKE : DLINK/AMP/RandM

26

-

-

... More
Supply Installation testing and commissioning of 24Port loaded Straight Jack pannel, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. MAKE : DLINK/AMP/RandM

1

-

-

... More
Supply Installation testing and commissioning of 17 U Wall Mount rack with front glass door lockable, Fans 90 Cfm 230 Vac, PDU Horizontal 5Amp with 6 Schokets, Cantilever Tray-1U, Horizontal PVC Cable Manager and Hardware front panel Mtg. including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. MAKE : DLINK/AMP/RandM

1

-

-

... More
Supply Installation testing and commissioning of AP Management License with 3 years comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. MAKE : RUCKUS/CISCO/ARUBA

1

-

-

... More
Supply Installation testing and commissioning of Indoor Access Point with secure Mounting Bracket and with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : The Access Point should have 2 auto MDX, auto-sensing 10/100/1000 Mbps RJ-45, with POE support on one port, and one USB port. AP should be IOT ready from day 1, The APs should support the IEEE 802.11a, 802.11b, 802.11g , 802.11n and 802.11ac Wave2 standards. It should support minimum 3 MU-MIMO clients simalteniously, The AP must support Dual Band Concurrent Operation - 2.4GHz and 5GHz, Should support 3 spatial streams on both radio bands for an aggregate capacity of 1.75 Gbps including 450Mbps on 2.4Ghz, The AP shall have a Minimum Rx Sensitivity of -100 dBm, The access points should be centrally managed. In some small isolated environments the AP should be able to function as a full-fledged stand-alone access point without the requirement of a controller, Security mechanisms should be in place to protect the communication between the Access Point controller and the Access Points, Since most radio interference come from the WLAN network itself the vendor should specify what mechanisms such as beam steering/ adaptive antenna technology/ beamforming are available in combination to focus the energy on the destination STA and minimize radio interference with the surrounding of the AP. The vendor should specify if the activation of such feature is still compatible with 802.11n spatial multiplexing, Since the WLAN network will be using an unlicensed band the solution should have mechanisms that reduce the impact of interference generated by other radio equipment operating in the same band, The access point should be able to detect clients that have dual band capability and automatically steer those client to use the 5GHz band instead of the 2.4GHz band, The antennas to be dual polarised and should be integrated inside the access point enclosure to minimize damage and create a low profile unit that does not stand out visually, The antennas to be dual polarised and should be integrated inside the access point enclosure to minimize damage and create a low profile unit that does not stand out visually, The access point should support 802.1q VLAN tagging, The access point should support WPA2 enterprise authentication and AES/CCMP encryption. AP should support Authentication via 802.1X and Active Directory, Implement Wi-Fi alliance standards WMM, 802.11d, 802.11h and 802.11e, The Access Point should provide for concurrent support for high definition IP Video, Voice and Data application without needing any configuration. This feature should be demonstratable,Support RF auto-channel selection by the following methods: a) measuring energy levels on the channel: b) monitoring for 802.11 signal structures and: (c) detecting radar pulses. Other similar forms of smart selection shall also be accepted, Channel selection based on measuring throughput capacity in real time and switching to another channel should the capacity fall below the statistical average of all channels without using background scanning as a method, AP should provide minimum 23 dBm Radio output power for 2.4Ghz and 5Ghz both. (EIRP should be limited as per govt regulation for indoor AP`s), Should support Transmit power tuning in 1dB increments in order to reduce interference and RF hazards, Device antenna gain (integrated) must be at least 3dBi and should provide automatic interference rejection of about 10dB, Upto 16 BSSIDs per AP for multiple differentiated user services (e.g. voice), Should support upto 500 clients per AP, Should support IPv4 and IPv6 from day one, The access point should support following security mechanism: WEP, WPA-PSK, WPA-TKIP, WPA2 AES, 802.11i,System should support Authentication via 802.1X, local authentication database, support for RADIUS and Active Directory, Mechanism for physical device locking using padlock /Kensington lock / equivalent, Operating Temperature: 0°C - 40°C, Operating Humidity: upto 95% non-condensing, Should be UL 2043 plenum rated and comply to WEEE/RoHS, Should be EN 60601-1-2 Medical compliant, Should be WPC approved: ETA certificate to be enclosed. MAKE : RUCKUS/CISCO/ARUBA

1

-

-

... More
Supply, Installation, Testing and Commissioning of Interactive Flat Panel Wall Mount - Technology TFT LCD with DLED Backlit: Display size (diagonal) 86` or Higher. Aspect Ratio 16:09: Resolution 3840 x 2160 4K Ultra HD: Flicker Free Yes with Blue Light Filter: static contrast ratio 1200:1 (typ): brightness 350 nits:display clour 1.07B colours:input ports HDMI x 3:VGAx1:display portx1:audiox1:CVBS(AV):RS232x1:PC slotx2:Slotin for pc built inx1:Wifi module slot built in x 1:output port HDMI x1:audio (earphone out)x1:SPIDFx1:LAN RJ45 x1:USB3.0 type A x3:2.0 typeA x3:2.0 type B(for touch) x2 :Speaker 16 w x2 :Touch type :IR recognition:touch resolution:32767x32767,Touch point:20 points:writing :10 points:response time(15ms:support:windows 10/windows8/windows7/windowsXP/Vista/LInux/MAC/ANdroid/wince/Chrome:embedded player CPU inbuilt Android Version:5.1:CPU:ARM quad core cortex A53 1.2Ghz:GPU ARM Mali-450 MP 4:Memory:2 GB:Storage:16GB eMMC:Networking:10/100M auto-identtification and DHCP:Anti Scratch-Anti Glare Minimum 7 H scratch resistant and anti glare :mirror extending flexibility to allow content to be mirrored on two IFB simultanesouly through HDMI out.Save option built in save option directly to Google Drive and One Drive. QR Code Scan:In Android Mode should have File download feature in smart phone just by scanning the QR code. Email: In Android juts by pressing of a icon the email should get generated and it should have facility to get the annotation/session attached as PDFautomatically. Split Screen: Should have the feature, built-in facility to split the screen in 2,3,4,5 or max.6 for simultaneous function/working on various application at the same time from a single PC. Annotation/Writing: Should be able to write on a Blank screen and on any application -PPT, Word, Excel, PDT, Web Browser, Video etc. Floating Tool: Should have floating tools which should appear just by press of 2 fingers for writing/annotation. Recording: It should also have recording function of Audio and Video. Quiz Built in Tool to allow participants to submit answwers from their Smart Phones, Zoom Video Conferencing - Built-in PC with IFP Core i5, DDR4 8GB, 2.5`,128 GB SATA S3 SSD, Network: Wireless 802.11: including the cost of all petty material required to complete the job upto the entire satisfaction of Engineer-in-charge Make: View Sonic/Samsung/Sony

1

-

-

... More
S/I/T/C of Two-Way 4` Coaxial Ceiling Loudspeaker with Frequency Range: 74 Hz - 20 kHz, Power Capacity (low-Z): 60 W Cont. ProgramMax. SPL: 102 dB @ 1m ave., 108 dB peak, Nominal Impedance: 8 ohms (in irect/bypass 8O setting), 70V/100V Transformer Taps, including the cost of all petty material required to complete the job upto the entire satisfaction of Engineer-in-charge. Make:-Bose/JBL/Audio tek

2

-

-

... More
Supply, Installation, Testing and Commissioning of Digital Podium – Material: Mild Steel: Should have Tray for Keyboard. ( Keyboard Dimension Standard Lenovo Keyboard): Should have built-in Visualizer and 19” Interactive Panel .It should also have the flexible options in sizes for the 21.5” or 23` Interactive Panel to fit in: Interactive Panel motorised positioning up and down as per the user convenience: Should have single Sliding tray to Protect the Interactive panel and for the controller:The top of the Podium should be wooden. Should have a space for the Desktop PC and for the equipments to fit in as per the International standards. Sliding Shelf 1) For Placement of extra laptop or Document 2) Drawer For Visualizer with Lock: Door Lock – Yes. Central Control System Should be able to control from the Controller with easy identified keys - Projector On Off , Motorised Screen Up and Down , Switching between PC, Visual Presenter and laptop, Volume Control. Front Panel should have- 17 Membrane keys for control, Power Plug 0f 220 Volt Power out for Laptop etc.,VGA Port X 01, 3.5mm Audio Input X 01,Network Port wired Internet x 01,USB X 02 Ports ,Ports for 6.35mm Microphone Input Back Panel of the Controller should have - Should have Projector IR Controller ,Should have 1 RS 232 Projector Control ,Should have 2 x 2 VGA matrix, Should have 2 HDMI Input and 1 HDMI Out, Should have 2 USB Ports for front, Connectivity, Should have Network Port for front connectivity, Should have2 Video In and 2 Video out, 2 Audio (Left) in , 2 Audio (Right) in, Should have 1 x Projector Power , 1 x Electric Screen Power: Built-in inputs on the left hand side : HDMI x 1, VGA x 1, USB Ports x 2, Power Plug x 1, Audio Mini In x 1, RJ 45 x 1, Microphone Input x 1, Video In x 1, Audio in ( Left and Right) x 2 Signal Switching :The Interactive Monitor touch should work independently for the both Laptop and PC. Whichever source is selected PC/Laptop when both are connected to the Podium the content should appear on Interactive Panel along with touch activated of the selected source, automatically without detaching or attaching a cable. CPU: Core i5 equivalent processor: Suitable express Chipset: 8GB RAM, 1TB HDD: OS: Windows 8 / 10: Keyboard and Mouse Built-in Audio Microphones: 1 x Gooseneck Mike: Frequency range 50 – 70000 Hz, Output Impedance at 1000Hz Should be rated at 150 O : Dynamic range and 1kO load- 96.2dB : Interactive Panel Panel Type:Active Matrix Color TFT: Display Size:19” or higher: Resolution: 1024 x 768 pixels: Brightness: 250cd/m2 or higher : Contrast: 1000:1: Connectivity : RGB/VGA : Interface: USB: including the cost of all petty material required to complete the job upto the entire satisfaction of Engineer-in-charge (NS) Make: ATDSC/LABWE/AHA

1

-

-

... More
Power Mixer SITC of Powered Mixer ideal for installs with inbuilt Class D amplifier, Max. midband output power, 1 kHz, THD = 1%, dual channel into 4 O :2 x 450 W into 8 O: 2 x 270 W , also capable of Direct-Drive option for 100V speaker lines. Frequency response, -3 dB, ref. 1 kHz,Any input to any Mixer output 15–22000 Hz.Crosstalk, 1 kHz Amplifier Ch1/Ch2 ( -85 dB.5 MIC/LINE input channels with compressor / limiter and talk-over function, 3 Stereo Inputs including Jack, RCA and USB connectors, onboard player for MP3 or WAV audio files, high quality effects section with 32 editable presets, 3 Master outputs with 7-band EQ each and flexible signal routing options, delay line for Master-B (150 msec / 50m), Auxiliaries (FX, AUX) 1 Post, 1 Pre ,Input impedances MIC 2 kO CD 10 kO All other inputs ) 15 kO, headphones control, LPN speaker processing, , comprehensive protection package, , optional rack mount kit, including the cost of all petty material required to complete the job upto the entire satisfaction of Engineer-in-charge. (NS) Make: Bosch / Bayerdynamics/Senneheiser

1

-

-

... More
SITC Speaker EN 54-24 Certified 20W wall mount speaker with excellent speech and High-fidelity music reproduction Max Power: 30W,Rated Power: 20Watts, Power Tapping:20/10/5/2.5W Effective frequency range(-10 dB) : 90 Hz to 20KHz SPL at rated power (1Khz at 1 m) 101 dB Opening Angle 1 KHz / 4 KHz (-6 dB): 174° / 136° (hor.) 127° / 141° (ver.) Woofer :- 5 inch : tweeter 1inch: Cabinet and front grill :- Aluminium Operating Temp : -25°C to plus 55°C : RH(95% EN60065: UL 94 V0 : Water and Dust protection :- EN60529 IP 65, including the cost of all petty material required to complete the job upto the entire satisfaction of Engineer-in-charge. (NS) Make: Bosch / Bayerdynamics/Senneheiser

6

-

-

... More
Wireless Lapel Mic SITC of Wireless Lapel Mic with Cardiod polar pattern for transmitter , Receiver and Transmitter frequency response 100Hz-18kHz or better,Receiver RF sensitivity ( 1.0 µV,Receiver Image rejection)55dB,Receiver Dyanmic range )95dB and receiver having 32 channels possible,Receiver S/N ratio )100dB A,distortion (1 %, Transmitter sensitivity - 5.6 mV/Pa,modulation: plus /-40kHz, including the cost of all petty material required to complete the job upto the entire satisfaction of Engineer-in-charge. Make: Bosch / Bayerdynamics/Senneheiser

1

-

-

... More
Wireless Handheld Mic SITC of Handheld Wireless Mic with Cardiod polar pattern for transmitter,Dynamic microphone with Neodymium magnet , Receiver frequency response 80Hz-18kHz,Receiver RF sensitivity ( 1.0 µV,Receiver Image rejection)55dB,Receiver Dyanmic range )95dB and receiver having 32 channels possible,Receiver S/N ratio )100dB A,distortion (1 %, Transmitter sensitivity - 3.2 mV/Pa,modulation: plus /-40kHz, including the cost of all petty material required to complete the job upto the entire satisfaction of Engineer-in-charge. Make: Bosch / Bayerdynamics/Senneheiser

1

-

-

... More
SITC of Dual Channel Power Amplfier - 300W Analog Input Signal to Noise Ratio (ref. rated power, 100V, 20Hz - 20kHz) at 8 ohms) ) 104dB Frequency Response (8O, 20 Hz - 20 kHz) plus /-0.5dB Crosstalk (below rated power) 20 Hz to 1 kHz ) 80dB also shall have GPIO/AUX Port – Recall presets, mute channels, monitor faults, power on/off the amplifier, and more through a combined GPIO/AUX Port, including the cost of all petty material required to complete the job upto the entire satisfaction of Engineer-in-charge. Make:-Bose/JBL/Audio tek

1

-

-

... More
SITC of Wireless Presenter Set Microphone System, Carrier frequency range 500.1 MHz – 864.9 MHz, Switching bandwidth 30.5 MHz (depending on local regulations), Audio bandwidth 35 to 20,000 Hz, Signal to Noise 120 dB-A, Up to 16 pre-programmed frequencies per group, including the cost of all petty material required to complete the job upto the entire satisfaction of Engineer-in-charge. Make:-Bose/AKG/Audiotek

1

-

-

... More
S/I/TC of 12x8 Digital Signal Processor with Digital link and AEC , 12 Analog Inputs (with 48v Phantom Power per Channel), 8 Analog Outputs, 12 Control Inputs and 6 Logic Outputs for GPIO Integration, Maximum Input Level: plus 20dBu with 0dB input gain, plus 8dBu with 12dB gain, Digital Input Impedance: 110 ohm (AES/EBU), 75 ohm (S/PDIF), Sample Rate: 48kHz or 96kHz, THD plus N: (-140dB, Maximum Analog Output Level: plus 19dBu, Frequency Response: 20Hz-20KHz ( plus 0.5dB/-1dB), THD: (0.01% 20Hz to 20KHz, plus 10dBu output, Dynamic Range: 108dB typical, 22Hz-22KHz unweighted, including the cost of all petty material required to complete the job upto the entire satisfaction of Engineer-in-charge. Make:-Bose/BSS/AMX

1

-

-

... More
All types of cables (Cat-6, HDMI, XLR/microphone cable of any length) and connectors required to complete the job in all respect i.e. connectivity of podium to IFP to delegate unit and viceversa to run all the equipments in tandem, including the cost of all petty material required to complete the job upto the entire satisfaction of Engineer-in-charge. Make: Krammer/Sommer/Belden/Bosch LBB / Bayerdynamics/senneheiser

1

-

-

... More
SITC of Analog input expander 8 analog MIC/Line input,2×RJ45 digital audio bus port,Phantom power on all inputs, including the cost of all petty material required to complete the job upto the entire satisfaction of Engineer-in-charge. Make:-Bose/BSS/AMX

1

-

-

... More
Supply Installation, Testing and Commissioning of POE Switch : 8 Port ,layer 2 with 8 Each.10/100/1000 basetx POE port with SFP port one no. dual personality GBE port for copper/fibre uplink.20 GBPS switching capacity,maximum power consumption 85 watt, including the cost of all petty material required to complete the job upto the entire satisfaction of Engineer-in-charge. (NS) Make : CISCO/Ruckus/HP

1

-

-

... More
SITC of 5.5KVA 4.4KW online UPS With inbuilt isolation transfomer with 30 minutes back up time,DEFAULT: 192VDC, ADJUSTABLE : 216VDC,SINGLE PHASE WITH GROUND,19.2KHz for high side IGBT and 50Hz for low Side -IGBT,Input nominal voltage-19.2KHz for high side IGBT and 50Hz for low Side -IGBT,ACCEPTABLE VOLTAGE RANGE-165-285V AC,FREQUENCY RANGE-40Hz - 55Hz @50 Hz System,OUTPUT NOMINAL VOLTAGE-208V AC / 220V AC/ 230VAC,AC VOLTAGE REGULATION- plus 1% (battery mode),FREQUENCY RANGE-Mains Mode(Synchronized Range): 45Hz - 55Hz/ Battery Mode: 50Hz 0.1Hz,TRANSFER TIME-AC TO DC MODE-Zero,INVERTER TO BYPASS MODE-Zero,BYPASS TO INVERTER MODE-‹5ms,WAVEFORM-Pure Sinewave,EFFICIENCY-AC MODE/ BATTERY MODE-87%/ 91%,RECOMMENDED BATTERY TYPE-SMF Battery,BATTERY CHARGING AMP.-2/4/ 8 AMP (D efault : 8 AMP.),NO. OF BATTERIES-16-18 Each(26AH),INDICATORS-Line ,Battery,Bypass,Fault,LCD DISPLAY-LOAD LEVEL, BATTERY LEVEL, AC MODE, BATTERY MODE, BYPASS MODE AND FAULT INDICATORS,ALARMS-Battery Mode: Sounding every 4 Seconds ,Overload: Sounding twice every second,Low Battery: Sounding every second, Fault: Continuously Sounding,MANAGEMENT-RS-232/ USB and BMS and SNMP interface,Supports Windows@ 2000/2003/XP/Vista/2008/7/8, Linux and MAC.with connection cables,accessories,suitable powder coated rack Make:-Eaton,Emerson,Microtek

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.