Chaudhary Charan Singh Haryana Agricultural University Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Chaudhary Charan Singh Haryana Agricultural University Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date10 Mar 2022
Closing Date21 Mar 2022
Tender Amount₹ 3,70,75,135 
Notes
Download

Costs

  • EMD

    ₹ 6,00,000
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded cum stone aggregate 40 mm nominal size) (HSR 6.1.6)

46.72

-

-

... More
Making plinth protection 50mm thick of cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (HSR 6.13)

114.21

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: (HSR 6.14.1) 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size)

233.72

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size) (HSR 6.15.1)

66.9

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.16)

341.99

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete (HSR 6.30.1)

162.48

-

-

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. (HSR 6.30.2)

170.56

-

-

... More
Suspended floors, roofs, landings, balconies (HSR 6.30.3)

1549.85

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers (HSR 6.30.5)

731.1

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts (HSR 6.30.6)

696.75

-

-

... More
Stairs, (excluding landings) except spiral-staircases (HSR 6.30.7)

24.15

-

-

... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc.complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more (HSR 6.34.6)

83539.3

-

-

... More
Half brick masonry with common burnt clay non-modular bricks of class designation 10 .5 in superstructure above plinth level up to floor IV level. Cement mortar 1 :4 ( 1 cement :4 coarse sand) (HSR 7 .28.2)

207.39

-

-

... More
Brick work with common burnt clay machine moulded nonmodular bricks of class designation 12.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1 :6 (1 cement : 6 coarse sand). Above plinth level up to floor IV level (HSR 7.40.2)

1

-

-

... More
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay non-modular bricks of class designation 7.5 including grouting with cement mortar 1 :4 (1 cement : 4 fine sand). (HSR 7.55)

171

-

-

... More
Brick work with non modular fly ash bricks conforming to IS :12894, class designation 10 average compressive strength in super structure above plinth level up to floor IV level in Cement mortar 1:6 (1 cement: 6 Coarse sand) (HSR 7.47.2)

209.49

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platfonns, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab over 0.50 sqm (HSR 8.26.2.2)

78.87

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work (HSR 8.27.2)

94.79

-

-

... More
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: With common burnt clay non-modular brick tile of class designation 10 (HSR 9.11.1)

714

-

-

... More
Providing gola 75x75 mm in cement concrete 1: 2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase (HSR 9.17.1)

133.89

-

-

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing periMeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and30 mm long, the periMeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of periMeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charae but excludina the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) (HSR 9.46.1)

24.25

-

-

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross 'T' of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main 'T' runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending. (HSR 9.47.1)

352

-

-

... More
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)

566.9

-

-

... More
Providing and laying of screed of 50 mm thick cement concrete 1 :8:16 to be laid below the topping. (HSR 10.4)

260

-

-

... More
Providing and laying of precast terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 12 mm, laid in floors, and landings, jointed with neat cement sluny mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1 :4 (1 cement:4 coarse sand) : Light shade pigment using white cement (HSR 10.26.1)

536.78

-

-

... More
Providing and laying of precast terrazzo tiles 20 to 22 mm thick with graded marble chips of sizes up to 12 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1 :3 (1 cement : 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of: Light shade pigment using white cement (HSR 10.28.1)

53.68

-

-

... More
Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand) : 25 mm thick (HSR10.37.1 )

366.93

-

-

... More
Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (HSR 10.38)

36.69

-

-

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 :4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (HSR 10.50.1)

47.28

-

-

... More
Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1 :3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. (HSR 10.51)

11.15

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (HSR 10.63.2)

277.45

-

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (HSR 10.67.2)

27.75

-

-

... More
Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm (HSR 10.70.2)

305

-

-

... More
6 mm cement plaster of mix 1 :3 (1 cement : 3 fine sand) (HSR 11.1.1)

1416.37

-

-

... More
12 mm cement plaster of mix : 1 :6 (1 cement: 6 fine sand) (HSR 11.5.4)

997.96

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1 :6 (1 cement: 6 fine sand) (HSR 11.6.2)

1596.92

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (HSR 11.60)

2597.87

-

-

... More
White washing with lime to give an even shade New work (three or more coats) (HSR 11.61.1)

1416.37

-

-

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer (HSR 11.64.1)

2594.87

-

-

... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)

269.39

-

-

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)

556.24

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 litre/1 O sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (HSR 11.95.1)

1091.27

-

-

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISi marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately} Kiln seasoned and chemically treated Hollock wood 30 mm thick shutters (HSR 12.7.2.2)

81.37

-

-

... More
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: Kiln seasoned and chemically treated Hollock wood (HSR 12.9.2)

15.68

-

-

... More
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: Float glass panes 4 mm thick glass pane (weight not less than 10kg/sqm). (HSR 12.9.7.1)

65.69

-

-

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (HSR 12.50.1)

4121

-

-

... More
Providing and fixing bright finished brass casement window fastener with necessary screws etc. complete. (HSR 12.58)

35

-

-

... More
Providing and fixing aluminium sliding door bolts, ISi marked anodised(anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm (HSR 12.98.2 )

47

-

-

... More
Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 200x10 mm (HSR 12.99.3)

92

-

-

... More
150x10 mm (HSR 12.99.4)

96

-

-

... More
100x10 mm (HSR 12.99.5)

10

-

-

... More
Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 125 mm (HSR 12.102.1)

126

-

-

... More
100 mm (HSR 12.102.2)

172

-

-

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper (HSR 12.103.1)

62

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (HSR 12.157.1.3)

75.87

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary, filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (HSR 12.157.2.3)

48

-

-

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides (HSR 12.158.2 )

1.95

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) (HSR 12.159.4)

6.48

-

-

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness (HSR 12.160.1)

2

-

-

... More
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge Polyester powder coated minimum thickness 50 micron (HSR 12.163.3)

4

-

-

... More
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. (HSR 12.164)

1

-

-

... More
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Up to 5mm depth and 5 mm width (HSR 12.169.1)

207.39

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb (HSR 13.3.1.1)

89.61

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C Fixing with adjustable lugs with split end tail to each jamb (HSR 13.3.2.1)

382.08

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile E Fixing with adjustable lugs with split end tail to each jamb (HSR 13.3.3.1 )

753.33

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1 .25 mm M.S. laths with 1.25 mm thick top cover (HSR 13.37.1)

112.25

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (HSR 13.41)

400

-

-

... More
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of sluny of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken up to 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately). For the purpose of measurement the entire treated surface will be measured. (HSR 28.16)

714

-

-

... More
Flush pointing with cement mortar 1: 3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for prefixed flat tile bricks on top of mud phaska: With F.P.S. brick tiles (HSR 30.20.1)

714

-

-

... More
Earth filling under floors with dune sand (tibba sand), brought from outside (any lead), in 15 cm layer including laying, dressing, watering ramming, consolidating, excavation, carriage, loading, unloading and compensation, etc., complete. (NS)

500

-

-

... More
Earth filling under road with dune sand (tibba sand), brought from outside (any lead), in 25 cm layer including laying, dressing, watering ramming, consolidating, excavation, carriage, loading, unloading and compensation, etc., complete. (NS)

200

-

-

... More
Providing and fixing C.I. grating over 100 mm dia rain water pipe, fixed in position, complete in all respects. (NS)

10

-

-

... More
Providing and fixing factory manufactured cement concrete 1:2:4 kerb finished smooth and of size 1’-0” x 1’-0” x 0’-6” of required shape and design fixed at ground level along with road, parking complete in all respect as directed by the Engineer-in-Charge but excluding cost of cement pointing. (NS)

100

-

-

... More
Providing and fixing factory manufactured cement concrete 1:2:4 channel finished smooth and of size 1’-0” x 1’-0” x 0’-3” of required shape and design fixed at ground level along with road, complete in all respect as directed by the Engineer-in-Charge but excluding cost of cement pointing. (NS)

100

-

-

... More
Providing and fixing 12 mm thick toughened glass ( Saint Gobin make) for door shutter including making holes for fixing accessories such as handles, L-connectors and cut out for floor machine etc., complete in all respect as directed by the Engineer In Charge. (excluding cost of handles, connectors and floor machine). (NS)

20

-

-

... More
Providing and fixing Glass Accessories i.e. handle of size 600 mmx 30 mm of DORMA make (model XL-C 3004) including cost of stainless steel screws etc., complete in all respect as directed by the Engineer In Charge. (NS)

8

-

-

... More
Providing and fixing Glass Accessories i.e. Glass Door package with lock (Floor machine) of DORMA make (model XL-C 4001) including cost of stainless steel screws etc., complete in all respect as directed by the Engineer In Charge. (NS)

2

-

-

... More
Providing and fixing PVC wall paneling consisting of 7mm thick cactus make hollow PVC section, PVC U section beading of size 25mmx8mmx12mm and PVC angle nosing of size 25mmx25mmx1.5mm including cost of PVC gutties, screws, jointed with polyfix (instant glue), complete in all respect as per drawing or as directed by Engineer-in-Charge. (NS)

150

-

-

... More
Providing and fixing frosted film of approved make, shade and colour, fixed in position on toughened glass including making design/pattern as per architectural drawing & design, complete in all respects. (NS)

8.4

-

-

... More
Providing and fixing 100mm wide vertical venetian blinds of required size and shape (Vista make select range), fixed in position, including rawal plugs and screws, etc. complete in all respects. (NS)

25

-

-

... More
Public Health work 84 to 150:- Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc, not exceeding 80 metre (HSR 4.16.1.1)

30.48

-

-

... More
Pipes, cables etc. exceeding 80 mm metre (HSR 4.16.1.2)

67.05

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)

8.04

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: (HSR 6.14.1) 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size)

0.7

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies (HSR 6.30.3)

8.22

-

-

... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc.complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more (HSR 6.34.6)

84

-

-

... More
Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.22.2)

1.61

-

-

... More
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)

19.68

-

-

... More
Providing and laying of screed of 40 mm thick cement concrete 1 :4:8 to be laid below the topping. (HSR 10.6)

25.57

-

-

... More
Providing and fixing granite stone in all shades 15mm to 18 mm thick in sqm skirting /dado/worktop/risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1 :3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. (HSR 10.51)

7.15

-

-

... More
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.62)

144.85

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (HSR 10.63.2)

45.25

-

-

... More
Cement Concrete 1 :8:16 Flooring Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. (HSR 10.100.2)

8.41

-

-

... More
12 mm cement plaster of mix : 1 :4 (1 cement: 4 coarse sand) (HSR 11.8.1)

16.69

-

-

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (HSR 13.27)

109

-

-

... More
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines 32 mm internal diameter (HSR 20.23.4)

3

-

-

... More
40 mm internal diameter (HSR 20.23.5)

1

-

-

... More
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required 11.43 cm thick wall (HSR 20.26.1)

10

-

-

... More
22.86 cm thick wall (HSR 20.26.2)

5

-

-

... More
Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repainting, replastering, replacing bitumen and colour or white washing where required 115 mm thickness of roof or floor (HSR 20.28.2)

2

-

-

... More
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I. pipelines laid in the ground or inside buildings, including cartage from divisional stores or nearest railway station to site of works 32 mm internal diametre (HSR 20.31.4)

3

-

-

... More
40 mm internal diametre (HSR 20.31.5)

1

-

-

... More
Making connection with the existing G.I. branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site. (HSR 20.36)

1

-

-

... More
Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1 :5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benchingb 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neat cement R.C.C. 1 :2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) (HSR 21.84.2)

3

-

-

... More
Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) (HSR 21.84.3)

5

-

-

... More
Extra for every 0.30 metre depth of Inspection chamber 400 mm x 600 mm inside (HSR 21.85.2)

0.9

-

-

... More
600 mmx 900 mm inside (HSR 21.85.3)

1.5

-

-

... More
Providing salt glazed stone ware pipes grade 'A' in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 induding the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. (HSR 21.94.2) 150mm i/d

67.05

-

-

... More
Providing and fixing white vitreous chinaware laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm (HSR 22.6.2)

4

-

-

... More
Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). One way (HSR 22.8.1)

4

-

-

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia (HSR 22.14.2.2)

12

-

-

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (HSR 22.15)

7

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (HSR 22.22.1)

3

-

-

... More
Providing and fixing white vitreous chinaware pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISi marked white solid plastic seat and lid (HSR 22.23.1 )

5

-

-

... More
Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required. Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern (HSR 22.26.4)

2

-

-

... More
Providing and fixing 8 mm dia C.P.S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. (HSR 22.38)

5

-

-

... More
Providing and fixing toilet paper holder C.P. brass (HSR 22.42.1)

4

-

-

... More
Providing and fixing partitions for different type of urinals. Large size 835mm x 355 mm White (HSR 22.50.1.2.1)

6

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes (HSR 22.86.2)

20.11

-

-

... More
25 mm nominal outer dia Pipes (HSR 22.86.3)

67.05

-

-

... More
32 mm nominal outer dia Pipes (HSR 22.86.4)

30.48

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal outer dia Pipes (HSR 22.87.5)

30.48

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore (HSR 22.103.3)

1

-

-

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore (HSR 22.104.1)

8

-

-

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore (HSR 22.107.1)

5

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore (HSR 22.108.1)

14

-

-

... More
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (HSR 22.109)

27

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (HSR 22.181)

2000

-

-

... More
Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc Aluminium coat and hat hooks One way ( HSR 22.212.2.1)

8

-

-

... More
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B 90 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.3)

46.94

-

-

... More
75 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.4)

48.76

-

-

... More
Providing and fixing in position v.chinawarwe W.H.B (Table top) (Aviator) Italian, white of Hindware make of size 59.50 x 42 x 15.5 cm, cat No. 91207, Star white (NS)

7

-

-

... More
Providing and fixing CP brass Piller tap of Jaquar make cat No. KUP-35021, white 190 mm (NS)

7

-

-

... More
Supply and fixing of PVC floor traps (Heavy duty) of 90 mm o/dia outlet of Prince /Supreme/Skipper make, complete in all respect. (NS)

24

-

-

... More
Supply and fixing of PVC gully traps (Heavy duty) of 100 mm dia size ( 4") with cover and frame of Prince/Supreme/skipper make complete in all respect. (NS)

6

-

-

... More
Supply of CPVC Union couplings with brass internal fittings, complete in all respect. (NS) Make:- Prince/Supreme/Skipper/ (a) For 32 mm nominal outer dia Pipes

3

-

-

... More
(b) For 40 mm nominal outer dia Pipes (NS)

2

-

-

... More
Supply of CPVC control valves (ball valves) with brass internals of Prince/Supreme/Skipper make . (NS) (a) For 32 mm outer dia pipes

3

-

-

... More
(b) For 40 mm nominal outer dia Pipes (NS)

2

-

-

... More
Supply and fixing of PVC elbows of followings sizes of Prince/ Supreme/ Skipper make. (NS) (i)110 mm o/d (4'' i/d)

9

-

-

... More
(ii) 90 mm o/d (4'' i/d)

3

-

-

... More
Providing and fixing CP grating 5" i/dia size of best quality, complete in all respect. Make:- Supreme/Skipper/Prince (NS)

24

-

-

... More
Providing and fixing looking mirror 5.5 mm thick in differnt sizes mounted on asbestos sheet ground fixed in position by means of 4 Nos. C.P. brass screws and washers on rubber washers and rawl plugs embeded in wall or CP brass clamps with CP brass screws etc. complete in all respect. Make:- Saint Gobain/MODI/ATUL (NS)

47

-

-

... More
Providing and fixing PVC door junctions of Prince/ Skipper/ Supreme make of following sizes.(NS) (i) 3'' x 3'' x 3'' i/dia

4

-

-

... More
(ii) 4'' x 4'' x 4'' i/dia

4

-

-

... More
Providing and fixing PVC Cowls of Prince/Supreme/Skipper make of following sizes. (NS) (a) 3'' i/dia

3

-

-

... More
(b) 4'' i/dia

2

-

-

... More
Electrical work 151 to 261:- Designing, Supply & erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 +(-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. a) Diesel Engine b) Alternator c) Battery 24 v. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) Tools, standard panel g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT's) h) Metering set 60/5A/11 OV (Amp. Meter, Volt Meter) i) Overload protection for DC-1 No. j) Battery Charger 24V DC k)Copper bus bar of suitable size I) KWH meter 96 sqmm size m) Starting fuse button and key switch9on/off) n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, De control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge 160 KVA (HSR 20.89.8)

1

-

-

... More
Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B (HSR 23.4.1.2)

300

-

-

... More
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire, including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B (HSR 23.4.4.2)

160

-

-

... More
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling, including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B (HSR 23.4.5.2)

162

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.5.6.2)

550

-

-

... More
1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.5.6.3)

350

-

-

... More
Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. (HSR 23.7.6.2)

2150

-

-

... More
FITTING AND ACCESSORIES Call bell 220/230 volts musical type (HSR 23.8.1.6)

10

-

-

... More
Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. (HSR 23.8.4)

71

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data (HSR 23.8.10.1)

132

-

-

... More
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 23.8.11.7) Step type Fan Regulator 2 modules 300 watt

71

-

-

... More
Telephone Socket outlet modular type (HSR 23.8.11.8)

24

-

-

... More
Blanking plate (HSR 23.8.11.10)

20

-

-

... More
RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type (HSR 23.8.11.11)

60

-

-

... More
Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA (HSR 23.22.1.9)

20

-

-

... More
4 pole MCCB 200 to 250 amp, 25 KA (HSR 23.22.1.11)

4

-

-

... More
4 pole MCCB 300 to 400 amp , 50 KA (HSR 23.22.1.12)

2

-

-

... More
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 4 way ( 2 incoming and 2 outgoing) (HSR 23.22.4.1)

8

-

-

... More
TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) (HSR 23.22.4.5)

3

-

-

... More
TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) (HSR 23.22.4.7)

5

-

-

... More
TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing) (HSR 23.22.4.8)

2

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole (HSR 23.22.5.1 )

261

-

-

... More
6 amp. to 32 amp MCB's FOUR POLE (HSR 23.22.5.7)

4

-

-

... More
40 amp to 63 amp. MCB's FOUR POLE (HSR 23.22.5.8)

7

-

-

... More
Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia (HSR 23.23.2.1)

71

-

-

... More
Supply and erection of blanking sheet in existing distribution board. (HSR 23.22.7)

19

-

-

... More
SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 400a mp 415 volts (HSR 23.22.8.5)

1

-

-

... More
Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire (HSR 23.23.8.1)

950

-

-

... More
Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required (HSR 23.23.9 )

2650

-

-

... More
Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current. The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1: 2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer- in-charge of the work:- M.S. pedestal of size 1500 mm wide , 1800 mm high ,450 mm deep and bottom totally open , duly embeded in cement concrete block of size 1650 mm x 600 mm x 200 mm above ground level , having a base of size 1 BOO mm x 750 mm x 250 mm below ground level . (HSR 23.27.6)

1

-

-

... More
EARTHING AND LIGHTENING ARRESTOR Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including each 3772 accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. (HSR 24.1.3)

8

-

-

... More
Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode. (HSR 24.1.5)

10

-

-

... More
Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. (HSR 24.1.4)

2

-

-

... More
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. (HSR 24.1.7)

20

-

-

... More
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.8)

10

-

-

... More
Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.9)

20

-

-

... More
Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.10)

10

-

-

... More
Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11)

40

-

-

... More
Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. (HSR 24.1.13)

20

-

-

... More
Laying of underground cable 0. 75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- 50 Sq mm to 150 sqmm 2 to 4 Core (HSR 24.2.2.3)

60

-

-

... More
300 sqmm to 400 sqmm 3 to 3½ Core (HSR 24.2.2.5)

950

-

-

... More
Laying of underground cable in pipe /existing open/closed trench etc as 16 Sq mm to 35s qmm 2 to 4 Core (HSR 24.2.3.2)

20

-

-

... More
50 Sq mm to 150s qmm 2 to 4 Core (HSR 24.2.3.3 )

40

-

-

... More
185 sqmm to 240s qmm 3 to 3½ Core (HSR 24.2.3.4)

40

-

-

... More
300 sqmm to 400 sqmm 3 to 3½ Core (HSR 24.2.3.5)

20

-

-

... More
Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50s qmm Cable 2 to 4 Core (HSR 24.2.7.3)

6

-

-

... More
70 sqmm to 95s qmm Cable 3 to 3½ Core (HSR 24.2.7.4)

6

-

-

... More
120 sqmm to 185 sqmm Cable 3 to 32 Core (HSR 24.2.7.5)

2

-

-

... More
300 sqmm to 400 sqmm Cable 3 to 3½ Core (HSR 24.2.7.7)

4

-

-

... More
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work . 25sqmm (HSR 24.2.8.5)

40

-

-

... More
70 sqmm (HSR 24.2.8.8)

8

-

-

... More
95 sqmm (HSR 24.2.8.9)

24

-

-

... More
185 sqmm (HSR 24.2.8.12)

8

-

-

... More
400 sqmm (HSR 24.2.8.15)

16

-

-

... More
S/E of underground cable XLPE LT CABLE aluminium conductor armoured .(NS) 25 sqmm 4 core cable (armoured)

150

-

-

... More
70 sqmm 3.5 core cable (armoured)

20

-

-

... More
95 sqmm 3.5 core cable (armoured)

70

-

-

... More
185 sqmm 3.5 core cable (armoured)

40

-

-

... More
300 sqmm 3.5 core cable (armoured)

1050

-

-

... More
S/E of PVC unsheathed copper conductor cable single core 1100 volt grade in pipe of suitable size excluding cost and erection of pipe (NS) (i) Size 1.5 sqmm(3/0.81mm)

3850

-

-

... More
(ii) Size 2.5 sqmm(3/1.05mm)

2650

-

-

... More
(iii) Size 4 sqmm(7/0.85mm)

1950

-

-

... More
v) Cable size 6 sqmm(7/1.05mm)

200

-

-

... More
(v) Cable size 10 sqmm(7/1.35mm)

100

-

-

... More
Supply, installation testing and commissioning of wall/free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2mm thick CRCA sheet, required hardware 3mm thick Bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of Zinc/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/switch wear. Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar Bakelite sheet 3mm thick for separately cable alley to BBC from switch chamber extended solid copper bars upto cable alleys shall provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wiring (copper) and fuse protection (Only outer area on all sides shall be measured) (NS)

20

-

-

... More
Supplying and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation complete in all respect. (NS)

50

-

-

... More
Pdg. & fixing digital metering equipment for LT cubical panel consisting of 96mmx96mm 0-500V, volt meter with selector switch, Amp. meter (of required ratio upto 600/5 amp.) with selector switch and required CTs 3 Nos. a set of 3 No. phase indication lamps RYB LED.(NS)

2

-

-

... More
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod and regulator . (NS) i) 1200mm sweep. Make: Usha, Orient, Crompton.

21

-

-

... More
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod and regulator (NS) i) 1400mm sweep. Make: Usha, Orient, Crompton.

50

-

-

... More
S/E of surface/wall mounted ≤20W integrated LED 4 feet fitting with Epoxy Powder coated white/Grey extruded aluminium channel housing for efficient heat dissipation. Total system lumen of 20 watt LED should be ≥ 2000 or above in cool day light (5700K to 6500K), Power factor 0.95, CRI 80, Average life 50000 hours. Complete with mounting Brackets & accessories as required with connections(Industrial) Make: Philips, Havells, Wipro, Bajaj. (NS)

21

-

-

... More
Supply of propeller type AC ventilating fan (exhaust fan) with necessary earthing arrangements of fan with shutter complete in all respects Size 300mm(12”) sweep Make: Orient, Usha, orient, Havells. (NS)

6

-

-

... More
S/E of recessed type 42 Watt full window glare free opal diffuse LED Panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 5100 or above in cool day light (5600K to 6500K), Power factor 0.95, CRI (Ra) 80, LED Lamp efficiency ≥ 140 lm/w, Average life 50000 hours, complete with all accessories as required with connections (Industrial) Make: Havells /Bajaj/Wipro/Philips (NS)

204

-

-

... More
Provision of CCTV:- Supply Installation testing & commissioning of 4MP IP Network Dome Camera with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Image Sensor : 1/3” 4 Megapixel Progressive scan CMOS sensor or better, Effective Pixels : 2688(H)x1520(V)) or better, Electronic Shutter : Auto/Manual, 1/3(4)~1/100000s, Scanning System : Progressive, Mini. Illumination : 0.08Lux/F2.0(Color); 0Lux (IR on), S/N Ratio : More than 50dB, Min. IR LEDs Length ≥50m, IR Leds : 1, Day/Night : Auto(ICR) / Color / B/W, Back Light Compensation : BLC / HLC / WDR(120DB), White Balance : Auto/Natural/Street Lamp/Outdoor/Manual, Motion Detection : Off/On (4Zone, rectangle), Focal Length : 3.6mm,Region of Interest : off/on(4Zone), Angle of View : H: 104° ,V: 57°, Video Compression : H.265+/ H.265, Resolution : 4MP (2688x1520)/3MP(2304x1296)/ 2MP(1920× 1080)/720P(1280× 720), Frame Rate (3 Stream) : Main stream (4MP (1 ~ 25/30fps)) & Sub stream : D1(1 ~ 25/30fps)& Third Stream : 720P (1 ~ 25/10fps), Digital Zoom : 16x, Bit Rate : H.265: 14 ~ 9984Kbps, Network Ethernet : RJ-45 (10/100Base-T), Flip : 0°/90°/180°/270°, Protocol : HTTP; HTTPs; TCP; ARP; RTSP; RTP; UDP; SMTP; FTP; DHCP; DNS; DDNS; PPPOE; IPv4/v6; QoS; UPnP;NTP; Bonjour; 802.1x; Multicast; ICMP; IGMP; SNMP, Compatibility : ONVIF, SD Card : Min 128GB SD card support, Power Supply : DC12V, PoE (802.3af), Working Environment : -30°C~+60°C / Less than 95%RH (no condensation), Ingress Protection : IP67, Audio Interface : Built-in-Mic, Intelligence (IVS) : Tripwire, Intrusion, Object Abandoned/Missing, Advanced Intelligent Functions : Face Detection, Certification : CE, FCC,UL (NS) MAKE : DAHUA/HYUNDAI/HONEYWELL/

36

-

-

... More
Supply Installation testing & commissioning of 6TB surveillance hard disk with the 3 years free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : WD-PURPLE/SEGATE

8

-

-

... More
Supplying, Installation,Testing & Commissioning of 43 " LED /LFDFull HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) 4000:1,Built-in Speaker (10W + 10W), Magic Clone (to USB), Auto Source Switching & Recovery, Lamp Error Detection, Super Clear Coating, Temperature Sensor, Plug and Play (DDC2B), Pivot Display, Clock Battery, PIP/PBP, Video Wall (10x10), Image Rotation, Button Lock, HDCP Support, Smart Scheduling, Smart F/W update, Built-In MagicInfo Premium-S with Mounting Brackets/stand as per Technical Specification complete in all respect. (NS) MAKE :- Sony / Samsung / LG

1

-

-

... More
Supply Installation testing & commissioning of 24 Port POE Access Switch with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Switch should offer Wire-Speed and Non-Blocking Switching with 24 10/100/1000 RJ45 PoE/PoE+ Ethernet ports and additional 4 SFP+ (1G/10G ) fiber based ports, Minimum 2 port Populated with 10G MMF,Access Switches should support non-blocking switching fabric capacity of minimum 88 Gbps  and minimum line-rate forwarding capacity of 57 Mpps, Access switch should support minimum 16K MAC addresses and minimum 4K active VLANs, Access Switch should have stacking capability with minimum stacking bandwidth of 40Gbps and should support a minimum of 8 units in a stack. Minimum one meter Stacking cables should be included in supplied material, Access switch should support up to 8 hardware queues per port, Access Switch should support full Layer 2 features like STP, RSTP,  LACP, ACL, QoS, IGMP v1/v2, Access Switch should support basic L3 features like IPv4 & IPv6 static routing, Layer 3/4 ACLs, ECMP, virtual interfaces and routed interfaces from day 1, Access Switch should be upgradable to support advance Layer 3 features like, RIPv1/v2, OSPF v2, OSPFv3, and HSRP/VRRP in future with an additional software license upgrade,Access Switch should support minimum 1K IPv4 routes, The Access Switch should support IPv6 management features like IPv6 ping, IPv6 trace route, IPv6 Telnet, IPv6 TACACS, IPv6  and IPv6 RADIUS, All Switches and Transceivers should be of same OEM make,Access switch should support minimum 4K ACL rules ACL per Switch, Access switch should support SNMP v1/v2/v3, SSH, NTP and web management, Access switch should have 1G of RAM and 2G of Flash Memory.(NS) MAKE : RUKUS/CISCO/HP

1

-

-

... More
Supply Installation testing & commissioning of 48 Port Non POE Access Switch with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support having following technical specifications :Switch architecture should be Fixed Form factor/ stackable based.Switch should have wire-speed, non-blocking and fanless designe Architecture.Switch should have minimum of 48 x 10/100/1000 Mbps RJ45 ports and additional 4 SFP+ (1G/10G ) fiber based ports, Minimum 2 port Populated with 10G MMF.Switch should have minimum of 136 Gbps or more data switching capacity and 95 Mpps or more forwarding throughput.Access Switch should have stacking capability with minimum stacking bandwidth of 40Gbps and should support a minimum of 8 units in a stack Minimum one meter Stacking cables should be included in supplied material.Switch should support min 16 K MAC addresses and min 4000 active VLANs.Switch should have full Layer 2 features like STP, RSTP, MSTP/PVST, LACP/IEEE802.3ad, ACL, QoS and IGMPv1/v2/v3.Switch should have Static Routing for IPv4 & IPv6.Access Switch should be upgradable to support advance Layer 3 features like, RIPv1/v2, OSPF v2, OSPFv3, and HSRP/VRRP in future with an additional software license upgrade.Should support 4K IGMP Groups.Should support 8 queues per port and security protocols like RADIUS, TACACS/TACACS+, AAA & SSH.Switch should be quoted with 3 years direct OEM TAC support and Next Business day hardware shipment.Proposed switch should be IPv6 logo certified, including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. MAKE : RUKUS/CISCO/HP (NS)

1

-

-

... More
Supply Installation testing & commissioning of Category 6 Patch Cord 6.5 feet, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/R&M /Molex

175

-

-

... More
Supply Installation testing & commissioning of 24Port loaded Straight Jack pannel, including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/R&M

4

-

-

... More
Supply Installation testing & commissioning of Horizontal PVC Cable Manager - 1U , including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/R&M

4

-

-

... More
Supply Installation testing & commissioning of 10GBASE-SR,SFPP MMF LC CONNECTOR with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : RUKUS/CISCO/HP

1

-

-

... More
Supply Installation testing & commissioning of DIRECT ATTACHED SFPP ACTIVE COPPER with 10G speed, 1M with the 3 years free comprehensive warranty period and 24x7 direct OEM TAC Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : RUKUS/CISCO/HP

1

-

-

... More
Supply Installation testing & commissioning of Video Management Recorder with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : Main Processor : Intel Quad-core Processor or better, Operating System :Embedded LINUX,IP Camera Input : 64 Channel or More, Two-way Talk : 1 Channel Input, 1 Channel Output/RCA, Interface : ≥2 HDMI (up to 3840 x 2160 , Different Source), ≥1 VGA, Compression : H.265/H.264, Resolution : 12MP, 8MP, 6MP, 5MP, 4MP, 3MP, 1080P, 1.3MP, 720P etc., Bandwidth : 320Mbps,Record Mode : Manual, Schedule (Regular, MD (Motion Detection), Alarm, Analytics), Holiday, Stop, Video Detection : Motion Detection/ Video Loss and Tampering/ Multiple VCA Event, Alarm input : ≥16 Channel, Relay Output : ≥8 Channel, Search Mode : Time /Date, Alarm, MD / Smart Search, Backup Mode : USB Device/Network/eSATA Device, Network Interface : 4 RJ-45 Ports (10/100/1000Mbps), Ethernet Port : 4 Ethernet Ports Joint Working or 4 Independent 1000Mbps Ethernet Ports, Network Function : HTTP, HTTPs, TCP/IP, IPv4/IPv6, UPnP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE,DDNS, FTP, Alarm Server, IP Search etc., Optical Fiber Interface : ≥2 Giga Optical Fiber Interface, User Access : ≥128 users, Smart Phone : iPhone, iPad, Android, Interoperability : ONVIF 2.4, CGI Conformant, Internal HDD : 16 SATA III Ports, Up to 8 TB capacity for each HDD, HDD Mode : Single, Raid 0/1/5/6/10, Support Global HDD Hot-spare, eSATA : 1 eSATA Port, SAS : 1 Mini SAS Port, for Storage Expansion,Front Cover : Support Hot-swap, USB : 4 USB Ports (2 USB 2.0 , 2 USB 3.0 ), RS232 : 1 Port, for PC Communication and Keyboard, RS485 : 1 Port, for PTZ Control, Power Supply,Redudant Power supply : Support, Operating Conditions : -10°C ~ +55°C, Certifications : CE,UL,FCC (NS) MAKE : DAHUA/HYUNDAI/HONEYWELL

1

-

-

... More
Supply Installation testing & commissioning of 17 U Wall Mount rack with front glass door lockable, Fans 90 Cfm 230 Vac, PDU Horizontal 5Amp with 6 Schokets, Cantilever Tray-1U, Horizontal PVC Cable Manager and Hardware front panel Mtg. including 3 years free comprehensive warranty period and cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : DLINK/AMP/R&M/MTS

2

-

-

... More
Supply Installation testing & commissioning of Indoor Access Point with secure Mounting Bracket and with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specifications : The Access Point should have 2 auto MDX, auto-sensing 10/100/1000 Mbps RJ-45, with POE support on one port, and one USB port. AP should be IOT ready from day 1, The APs should support the IEEE 802.11a, 802.11b, 802.11g , 802.11n & 802.11ac Wave2 standards. It should support minimum 3 MU-MIMO clients simalteniously, The AP must support Dual Band Concurrent Operation - 2.4GHz and 5GHz, Should support 3 spatial streams on both radio bands for an aggregate capacity of 1.75 Gbps including 450Mbps on 2.4Ghz, The AP shall have a Minimum Rx Sensitivity of -100 dBm, The access points should be centrally managed. In some small isolated environments the AP should be able to function as a full-fledged stand-alone access point without the requirement of a controller, Security mechanisms should be in place to protect the communication between the Access Point controller and the Access Points, Since most radio interference come from the WLAN network itself the vendor should specify what mechanisms such as beam steering/ adaptive antenna technology/ beamforming are available in combination to focus the energy on the destination STA and minimize radio interference with the surrounding of the AP. The vendor should specify if the activation of such feature is still compatible with 802.11n spatial multiplexing, Since the WLAN network will be using an unlicensed band the solution should have mechanisms that reduce the impact of interference generated by other radio equipment operating in the same band, The access point should be able to detect clients that have dual band capability and automatically steer those client to use the 5GHz band instead of the 2.4GHz band, The antennas to be dual polarised and should be integrated inside the access point enclosure to minimize damage and create a low profile unit that does not stand out visually, The antennas to be dual polarised and should be integrated inside the access point enclosure to minimize damage and create a low profile unit that does not stand out visually, The access point should support 802.1q VLAN tagging, The access point should support WPA2 enterprise authentication and AES/CCMP encryption. AP should support Authentication via 802.1X and Active Directory, Implement Wi-Fi alliance standards WMM, 802.11d, 802.11h and 802.11e, The Access Point should provide for concurrent support for high definition IP Video, Voice and Data application without needing any configuration. This feature should be demonstratable,Support RF auto-channel selection by the following methods: a) measuring energy levels on the channel; b) monitoring for 802.11 signal structures and; (c) detecting radar pulses. Other similar forms of smart selection shall also be accepted, Channel selection based on measuring throughput capacity in real time and switching to another channel should the capacity fall below the statistical average of all channels without using background scanning as a method, AP should provide minimum 23 dBm Radio output power for 2.4Ghz and 5Ghz both. (EIRP should be limited as per govt regulation for indoor AP's), Should support Transmit power tuning in 1dB increments in order to reduce interference and RF hazards, Device antenna gain (integrated) must be at least 3dBi and should provide automatic interference rejection of about 10dB, Upto 16 BSSIDs per AP for multiple differentiated user services (e.g. voice), Should support upto 500 clients per AP, Should support IPv4 and IPv6 from day one, The access point should support following security mechanism: WEP, WPA-PSK, WPA-TKIP, WPA2 AES, 802.11i,System should support Authentication via 802.1X, local authentication database, support for RADIUS and Active Directory, Mechanism for physical device locking using padlock /Kensington lock / equivalent, Operating Temperature: 0°C - 40°C, Operating Humidity: upto 95% non-condensing, Should be UL 2043 plenum rated and comply to WEEE/RoHS, Should be EN 60601-1-2 Medical compliant, Should be WPC approved; ETA certificate to be enclosed. (NS) MAKE : RUCKUS/CISCO/ARUBA

8

-

-

... More
Supply Installation testing & commissioning of AP Management License with 3 years comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE : RUCKUS/CISCO/ARUBA

8

-

-

... More
Supply, Installation and commissioning of 1 x 20 KVA UPS Each UPS of 20 KVA/16 KW should have following specifications in addition to tender requirements : True online double conversions,with inbuit isolation transformer ,IGBT Rectifier & inverter based UPS. Three phases Input/ three phase output with SMF batteries Suitable for 30 Min backup on Full load (20 KVA) at 0.8 output power factor. Input voltage range 360-478V at 100% load, 220-478 V @ 50% load. Input power factor 0.99,Output THD is less than 3% for linear load. Less than 5 % for nonlinear load. Crest factor 3:1, over load 125% for 10 min, 150% for 1 min and should be able to operate continuously at 115% load on bypass mode. Battery voltage Adjustable from 384VDC to 480 VDC on site. Battery Bank sizing as 42 AH x 40 nos. X 1 String. Battery type should be Valve regulated lead-acid (VRLA) of make Exide/Panasonic/QUANTA/Rocket. Audible noise level should not exceed 63 dB (A). Parallel communication port, RS232. USB EPO and SNMP interface, BMS interface are required. EMC-IEC62040-2 safety-IEC62040 II operating temperature 0-40 deg C, relative humidity 95% Non-Condensing. No derating e to 40 Deg temp.. UPS shall have inbuilt Input Isolation Transformer. static by pass and manual by pass built in required. Third party test report through accredited lab like TUV is required for IEC 62040-3 and IP20. UPS should be provided with environment monitoring probe to measure temperature and humidity of UPS room. UPS shall have dust filter sat Air Inlet level to improve UPS reliability. LCD Display indicating all important parameters. SNMP software should be compatible to Microsoft windows XP, Windows Vista, Window 8, Window server 2003 R2, UPS software should be compatible to google chrome, Mozilla fire fox and Microsoft internet explorer. Battery rack, battery interlinks battery breaker, battery to UPS cable as required should be provided with UPS systems. (NS) Make: Elnova, Eaton, Peagasus,GE,Gutor

1

-

-

... More
Wi-fi system:- Supply Installation testing & commissioning of WLAN Controller WITH 3 YEAR Support including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having following technical specification : WLAN Controller should have minimum 2 nos. of 10/100/1000 Ethernet or SFP Ports and one Console port. (NS) (MAKE : RUCKUS/CISCO/ARUBA) Proposed Controller should be ready for supporting 50 AP’s from day one with scalability for 75 AP support in future without adding any new hardware. Controller should be able to support minimum 75 campus connected AP’s or more with support of seamless roaming access over L2/L3 network. Controller should support minimum 250 WLAN’s , Controller should have capacity to handle minimum 2000 or more Concurrent devices. General Feature Controller should provide air-time fairness between these different speed clients – slower clients should not be starved by the faster clients and faster clients should not adversely affected by slower clients. Controller should support Spectrum Analysis feature to detect interference from different sources., System Should provide real-time charts showing interference for access point, on a per-radio, per-channel basis. Ability to map SSID to VLAN and dynamic VLAN support for same SSID. support automatic channel selection for interference avoidance Controller must support 802.11k and 802.11r. Auto Deployment of AP's at different locations Access points can discover controllers on the same L2 domain without requiring any configuration on the access point. Access points can discover controllers across Layer-3 network through DHCP or DNS option ,Security & monitoring , Controller should support following for security & Authentication: WIRELESS SECURITY: WEP, WPA-TKIP, WPA2-AES, 802.11i AUTHENTICATION : 802.1X, local database External AAA servers : Active Directory, RADIUS, LDAP System should provide DOS attacks and Intrusion Detection & Prevention and Control for any Rough Access Points., Controller should support CAPWAP/LWAPP protocol. System must be able to provide L2/L3/L4 Access Control. Controller Should support L2 Client Isolation so User cannot access each other’s devices. Isolation should have option to apply on AP or SSID's. Controller should be able to create local database of up to 2000 users. Controller should support Access Control based on Identity/Role/ Device/time or Application. , Support for Walled garden “Walled Garden” functionality to allow restricted access to select destinations by unauthorized wireless users. IPv4 & IPv6 support from Day 1 , Should support on board and external DHCP server Controller should support integrated or External AAA server including Microsoft AD and Linux based open source AAA servers. , The proposed architecture should be based on controller based Architecture with thick AP deployment. While Encryption / decryption of 802.11 packets should be able to perform at the AP. , The Controller should support OS/Device finger printing and device type based policies i.e allow or deny, Bandwidth rate limit, VLAN mapping. , The controller shall be manageable using CLI, Telnet/SSH, HTTP based GUI and SNMPv2/v3. , The controller should be able to present a customizable dashboard with information on the status of the WLAN network. The controller should be able to raise critical alarms by sending an email. The email client on the controller should support SMTP outbound authentication and TLS encryption. The vendor should specify if all features are available with the basic access controller pricing or if the support of some features require the acquisition of some licenses. The vendor should specify which feature requires which type of licensing including its cost. Controller should have inbuilt BYOD features and Guest Access management procedure where user may use internet without entering to Enterprise SSID and should be time restricted. The Guest management should be a self-service one from end user perspective without the use of any additional software. , QoS features per SSID or dynamic Per user bandwidth Rate Limiting , Self-healing (on detection of RF interference or loss of RF coverage) and vendor should provide their Interference mitigation techniques for same Domain interference (interference from AP's connected to same Controller) and from other AP's and 2.4Ghz devices (Microwave's, Radio's etc.) Dynamic RF management that provides the capability to pause channel scanning / adjust RF scanning intervals based on application and load presence. Capability to provide preferred access for “fast” clients over “slow” clients (11n vs. 11g) in order to improve overall network performance. System must support Band Steering where 5 Ghz clients are forced to connect over 5Ghz Radio to provide better load balancing among 2.4Ghz and 5Ghz Radios. Support advanced multicast features and WMM support to provide best performance on Video applications. Should have Voice Call Admission control , Client Management The controller should provide a Guest Login portal in order to authenticate users that are not part of the organization. , The solution should be able to provide a web-based application that allows non-technical staff to create Guest accounts with validity for fixed duration like hours or days. , System should be able to send password direct through Email and SMS to the user., System should be able to generate one click password for single user, multiple users or single user multiple devices., System should support internal and External Database for user authentication. System should support user management features like Rate limiting based on time based WLAN Access & User profile per WLAN etc. ,Regulatory ,Wi-Fi Alliance certified

1

-

-

... More
Supply Installation testing & commissioning of 12-core Singlemode OFC cable including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge.(NS) (MAKE : Molex/Siemon/Dlink)

1000

-

-

... More
Supply Installation testing & commissioning of Single mode Fibre Patch cord including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) (MAKE : Molex/Siemon/Dlink)

2

-

-

... More
Supply Installation testing & commissioning of Black, 12F, L1U, Loaded with, Splice tray, Couplers & Pigtails including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) (MAKE : Molex/Siemon/Dlink)

1

-

-

... More
Supply Installation Testing and Commissioning of Digital central controller for powering and controlling of discussion devices. The controller should have connections at rear to connect audio peripherals or conference dome cameras. The system settings such as microphone management should be configurable from software on a PC/tablet using web browser. The number of open microphones should be controllable from either the control unit itself or web based software. The controller should be able to accommodate upto 10 number of open microphones. The control unit should be capable of connecting to cameras for conference room, external wired/wireless microphone, sound reinforcement systems, audio equipment, external audio processor, telephone coupler, external recorder or computer. The control unit should have the following modes : Open mode - Participants speak by pressing their PTT button. When max no. of open mics reached the next participant is automatically waitlisted. Over ride mode - when max no. of open mics reached the first mic to be switched on is automatically switched off. Voice activated mode - mics switch on their own when participant speaks near the mic. PTT mode - Participant presses his PTT button and the mic is switched on till the time button is pressed. • Inbuilt MP3 recorder which can support upto 128GB flash drive or 4000 hours of discussion. • Inbuilt digital acoustic feedback suppressor to control acoustic feedback or howling in the system. • No. of discussion devices - max 40 per trunk line. • Sample rate 44.1kHz. • Frequency response - 30Hz - 20kHz. • S/N 94dBA. (NS) Make:-Bosch/Brahler /Beyar Dynamic

1

-

-

... More
Supply Installation Testing and Commissioning of digital chairman unit with priority, inbuilt speaker, PTT button and 48 cm long gooseneck microphone. The unit should have following features: • Possible to speak indicator - The microphone should have a white LED indication which shows when the microphone can be activated; • Request to speak indicator - the microphone should have a green LED indicator when the microphone is in queue to be activated; • Built in loudspeaker with volume controller; the unit shoul dhave built in head phone socket with volume control for the same. • The discussion unit should have immunity from mobile phone signals. • Frequency response - 200Hz-12.5kHz; • Loud speaker output - 72dB SPL Make:-Bosch/Brahler /Beyar Dynamic (NS)

1

-

-

... More
Supply Installation Testing and Commissioning of digital delegate unit with inbuilt speaker, PTT button and 48 cm long gooseneck microphone. The unit should have following features: • Possible to speak indicator - The microphone should have a white LED indication which shows when the microphone can be activated; • Request to speak indicator - the microphone should have a green LED indicator when the microphone is in queue to be activated; • Built in loudspeaker with volume controller; the unit shoul dhave built in head phone socket with volume control for the same. • The discussion unit should have immunity from mobile phone signals. • Frequency response - 200Hz-12.5kHz; • Loud speaker output - 72dB SPL Make:-Bosch/Brahler /Beyar Dynamic (NS)

20

-

-

... More
Supply Installation Testing and Commissioning of DSP with USB THD+N (22Hz to 22kHz) 0.002% (1kHz @ +4dBu)EIN 125dBu, unweighted (20Hz to 20kHz)Dynamic Range 110dB, unweighted,Propagation Delay 4ms, Crosstalk, input to input, 1kHz 110dB Sampling Rate 48kHz A/D-D/A Converters 32-bit Acoustic Echo Cancellation Requires HearClear™ license; 250ms latency at eight channels, 100ms at 16 channels BTU/Heat Load 44 BTU/hr, Processor Type 40-bit floating point Phantom Power +48VDC (with XC-SML) up-to 75mA maximum Power Supply IEEE 802.3af, Class 0 Power-over-Ethernet Power Consumption 13W maximum Ambient Operating Temperature 32-104°F (0–40°C) Humidity 0–98%, non-condensing Altitude 0-6,600 feet (0–2000 Meters) MSL Network Connections 2x RJ45 (≥Cat 5e) including dedicated 1000Mbps Dante™ connection and, separate Ethernet port for control and Power-over-Ethernet USB (with XC-SUB) Bit depth: 16-bit, Number of channels: 2x2, send and receive, Driver sample rate: 48kHz Card sample rate: follows DSP settings, Connector: USB B, female Dante™ 4x4 bi-directional; AES67.MAKE:- Xilica/Audio Technica/BSS/Bosch/Brahler /Beyar Dynamic (NS)

1

-

-

... More
Supply Installation Testing and Commissioning of Amplifier Channels 4 Sensitivity (for full rated power at 8 ohms) 0.7V RMS Rated Power Output (per channel @ 4 ohms) 300W Analog Input Signal to Noise Ratio (ref. rated power, 100V, 20Hz - 20kHz) at 8 ohms) 104dB THD (full rated power, 20 Hz - 20 kHz) 0.35% Damping Factor (20 Hz to 100 Hz) 1000 Frequency Response (8Ω, 20 Hz - 20 kHz) +/-0.5dB Crosstalk (below rated power) 20 Hz to 1 kHz 80dB Input Impedance (nominally balanced, nominally unbalanced) 20 kΩ balanced, 10 kΩ unblanced Dimensions (inches) (W x H x D) (depth not including 1.3 inch front panel protrusion) 19 x 3.5 x 12.25 Weight 16.13 lbs (7.31 kg) Power Supply Connector "Standard IEC type 320 inlet for detachable connector 100 – 240V~".Make:-Bosch/Brahler /Beyar Dynamic (NS)

2

-

-

... More
Supply Installation Testing and Commissioning of 30W ceiling/wall mount Premium-sound cabinet loudspeaker High-Fidelity music and speech reproduction, Selectable 8 ohm, 70V and 100V inputs, Safety acc. to EN60065, water production acc. to EN60529 IPx4. Power tapping - 30/15/7.5/3.75W, Sound pressure level at rated power/1 W(1kHz, 1 m) 105/90 dB (SPL), Effective Frequency Range (- 10dB) 100Hz to 19kHz. Make:-Make:-Bosch/Brahler /Beyar Dynamic (NS)

18

-

-

... More
Supply , Installation , Testing & Commissioning of Full HD 20X Optical Zoom Camera With HDMI, USB,,LAN ports features advanced ISP processing algorithms and exceptional Pan-Tilt mechanism to provide high resolution, vivid performance and smooth moves. HD Pan/Tilt/Zoom (PTZ) camera has USB 3.0 and HDMI and IP video output interface , equipped with a high performance imaging, fine detail, and color rendering with 1/2.8″ low-noise, HD CMOS image sensor with Full HD 1080p output resolution and a high dynamic image of 60 fps. The superior 20x optical zoom lens,wide shooting angle and achieves high-speed, quiet, and precise positioning with smooth PTZ operations. There are up to 255 preset setting movements and stable remote controlling for displaying effective and efficient presentations supports VISCA, Pelco-D, and Pelco-P camera control protocols TCP/IP, RS-232, USB, and IR control,remote control ,Minimum Illumination 0.5 Lux @ F 1.8 (AGC ON) ,Focal Length 5.5 – 110 mm (20x), F Number F1.6-F3.5, Field of View 55.8° (wide) – 3.2° (tele) , Pan/Tilt Rotation -170°∼+170°, -30°∼+90° , Network Protocol RTSP, RTMP, ONVIF , GUI-based configuration. Make:-Solvision/Panasonic/Sony (NS)

1

-

-

... More
S.I.T.C. of 55" 4k Display panel for viewing content- LED display, HDMI X 2, DVI X 1, DP X 1, VGA X 1, Video IN X 1, Component x 1, USB X 2, RS232 X 1, Audio IN X1, 20W in built speaker, IPS LED display, USB media player, Auto Input search, Auto sleep, Auto wakeup, Auto source detect Make:-Panasonic/LG/Samsung (NS)

1

-

-

... More
S.I.T.C. of 86" Intractive flat Panel, IR touch technology, IPS Panel UHD Native Resolution ( 3849 x 2160 ), Brightness 330 Nits; Contrast ratio 1100:1, response time :8ms, Orientation Landscape Connectivity. ( Input ) Video / Audio HDMI (3), RGB / Audio in(input) External Control rS232C In,RJ45 (Input) USB USB 2.0 (3, Front : 2ea, Bottom side :1ea Only for software. Audio HDMI (1), Optical Output / Audio Out with OPS i5 system Touch type IR. Available object size for touch Ø3 mm ↑ Response Time 60ms ↓ (Andriod) / 100ms ↓ (Windos) Accuracy 1.5mm Unreface USB 2.0 Protection Glass Thickness 4T (Anti - Glare) Make Panasonic,Samsung,LG, Sony, View Sonic etc. (NS)

3

-

-

... More
Supply, Installation, Testing, Commisioing of Interactive Digital Podium system with 16" interactive screen EMR technology, also available Gooseneck Microphone inbuilt Aluminium plated system Interface : USB, Pressure sensitive. Still image Resolution: XGA,SXGA,720P, 1080P, FRAME RATE 20 FRAMES/SEC. Image Mode: Normal/photo/Text/Slide/Film/Gray. Inputs- VGAx 2, HDMIX 1, Video x 2, Audiox 2 Outputs- VGA x 2, hHDMIX 1 VIDEOX1 AUDIO X1. Make:-AHA/Digital Podium Media (NS)

3

-

-

... More
Power Mixer - SITC of Powered Mixer ideal for installs with inbuilt class D amplifier , max. midband output power, 1 khz, THD = 1%, dual channel into 4Ω : 2 x 450 W into 8Ω : 2 x 270 W, also capable of Direct - Drive option for 100V speaker lines. Frequency reponse, -3db, ref. 1khz, any input to any Mixer output 15-22000 Hz. Crosstalk , 1khz Ampifier Ch1/Ch2˂ -85 db. 5 MIC/LINE input channels with compressor / limiter and talk over function, 3 Stereo inputs including jack, RCA and USB connecters, onboard player for MP3 or WAV audio files, high quality effects section with 32 editable presets, 3 master outputs with 7-bands EQ each and flexible signal routing options, delay line for Master-B (150msec) / 50m), Auxiliaries (FX,AUX) 1 Post 1 Pre, Input impedences MIC 2kΩ Cd 10kΩ All other inputs ˃ 15kΩ, headphones control, LPN speaker processing, comprehensive protection package, optional rack ,ount kit. Make Bosch //Brahler /Bayerdynamics / Senneheiser etc. (NS)

3

-

-

... More
Supply, Installation, Testing and Commissioning of XLR cables -of different sizes : Male,females, Speakon connectors, conducting, solding etc . (NS)

3

-

-

... More
Supply, Installation, Testing and Commissioning of HDMI Cable 10 Meter High Speed HDMI Cable; Ethernet, 3D, 4K, Audio Return Supported;Gold Plated Connector; Bare Copper Connector for high quality transmission; full metal jacket with shielding; 0% transmission loss. (NS) MAKE : Stacker/Aten/Kramer/TEKWIN/WBOX

3

-

-

... More
Providing and installing split type air conditioners, five star rating inverter type with copper coils 2.0 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-32/R-410-A suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:-(i) Cooling coil row -3 Nos.(ii) Air flow (CMH) - 800 to 1400 cum/ hr.(iii) Sound level (H/M/L)- 41/38/34/25(silent mode)(iv) Louvers swing- 3D + 3D Auto etc. complete in all respectMAKE :- O General/Mitsubishi (Heavy Industries)/Hitachi (five star rating) Model as approved by the Engineer-in-Charge. (NS)

24

-

-

... More
Providing and installing split type air conditioners, five star rating inverter type with copper coils 1.5 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-32/R-410-A suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:-(i) Cooling coil row -3 Nos.(ii) Air flow (CMH) -600 to 1100 cum/ hr.(iii) Sound level (H/M/L)- 41/38/34/25(silent mode)(iv) Louvers swing- 3D + 3D Auto etc. complete in all respectMAKE :- O General/Mitsubishi (Heavy Industries)/Hitachi (five star rating) Model as approved by the Engineer-in-Charge (NS)

8

-

-

... More
Providing and installation of automatic voltage stabilizer of 5.00 KVA capacity (heavy duty) copper wound 100 up voltatge of Voltstar / microtek/V-guard make ISI marked complete in all respect. (N.S.)

32

-

-

... More
Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing & laying refrigerant pipe line of four metres length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing & laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring ; suitable electric wiring and switch should be provided with in 4 metres of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4") (ii) Gas line:- 15.88mm(5/8") 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit. (NS)

160

-

-

... More
Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts & bolts etc. of best quality complete in all respect (NS)

32

-

-

... More
S/I/T/C of push ON/OFF type 25 A modular type motor starter switch (white color) for AC's including the cost of petty material required to compete the job upto entire satisfaction of Engineer-in-charge. (NS) Make;- Schneider/Crabtree/Athena

32

-

-

... More
S/I/T/C of CPVC/UPVC Pipe for Drainage System of Air Conditioners 25mm dia including the cost of petty material required to compete the job upto entire satisfaction of Engineer-in-charge. (NS) Make;- Finolex/Ravindra/Supreme

224

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.