If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Chaudhary Charan Singh Haryana Agricultural University Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Sep 2023
Closing Date30 Sep 2023
Tender Amount₹ 5,00,000 
Notes
Download

Costs

  • EMD

    ₹ 10,000
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 1,180

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc. exceeding 80 mm metre (HSR 4.16.1.2)

1

-

-

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc. exceeding 300 mm metre (HSR 4.16.1.3)

1

-

-

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge In cement mortar (HSR 5.7.4)

1

-

-

... More
Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): From brick work in cement mortar (HSR 5.8.3)

1

-

-

... More
Demolishing cement concrete manually/ by mechanical means direction of Engineer - in - charge. Nominal concrete 1 :2:4 or leaner mix (i/c equivalent cum design mix) (HSR 5.23.2)

1

-

-

... More
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. (HSR 5.27)

1

-

-

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: Of area 3 sq. metres and below each (HSR 5.29.1)

1

-

-

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: Of area beyond 3 sq. metres each (HSR 5.29.2)

1

-

-

... More
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead Of area 3 sq. metres and below (HSR 5.30.1)

1

-

-

... More
Removing rolling shutters including top cover, brackets and side guides etc.complete (HSR 5.41)

1

-

-

... More
Dismantling cement conglomerate / terrazzo floors 25 mm to 50 mm manually/ by mechanical means and disposal of material within standard lead as per direction of Engineer- in-charge. (HSR 5.42)

1

-

-

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm (HSR 5.43.1)

1

-

-

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm (HSR 5.43.2)

1

-

-

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead). (HSR 5.45)

1

-

-

... More
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 Meters lead as directed by Engineer-in-charge. (HSR 5.49)

1

-

-

... More
Removal of old broken glass panes (any thickness or size, quality or description) from wooden frames, glazed with putty or fixed with beads. (HSR 5.50)

1

-

-

... More
Removing old broken/serviceable glass of any thickness or size or description except polished plate glass from old wood or metal frames etc.(any thickness or size) hacking out old putty etc. including making good breakages in talking out and handling complete. (HSR 5.51)

1

-

-

... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (HSR 5.70)

1

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)

1

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:3:6 (1 Cement : 3 coarse sand (zone-Ill) : 6 graded cum stone aggregate 20 mm nominal size (HSR 6.1.4)

1

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:3:6 (1 Cement : 3 coarse sand (zone-Ill): 6 graded cum stone aggregate 40 mm nominal size) (HSR 6.1.5)

1

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded cum stone aggregate 40 mm nominal size) (HSR 6.1.6)

1

-

-

... More
Providing and laying damp-proof course with cement concrete 1: 1.5:3 (1 cement : 1.5 coarse sand (zone-Ill): 3 graded stone aggregate 20mm nominal size) 40 mm thick (HSR 6.9.2)

1

-

-

... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1. 7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. (HSR 6.10)

1

-

-

... More
20 mm thick cement plaster damp-proof course 1 :3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded Vertical (HSR 6.12.1)

1

-

-

... More
20 mm thick cement plaster damp-proof course 1 :3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded Horizontal (HSR 6.12.2)

1

-

-

... More
Making plinth protection 50mm thick of cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (HSR 6.13)

1

-

-

... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diaMeters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D kg or more. (HSR 6.33.6)

1

-

-

... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc.complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more (HSR 6.34.6)

1

-

-

... More
Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.21.1)

1

-

-

... More
Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.21.2)

1

-

-

... More
Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.22.1)

1

-

-

... More
Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.22.2)

1

-

-

... More
Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in foundations and plinth in: Cement mortar 1:3 (1 cement: 3 coarse sand) (HSR 7.27.1)

1

-

-

... More
Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in foundations and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.27.2)

1

-

-

... More
Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. Cement mortar 1:3 (1 cement :3 coarse sand) (HSR 7.28.1)

1

-

-

... More
Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. Cement mortar 1 :4 ( 1 cement :4 coarse sand) (HSR 7 .28.2)

1

-

-

... More
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay non-modular bricks of class designation 7.5 including grouting with cement mortar 1 :4 (1 cement : 4 fine sand). (HSR 7.55)

1

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Marble work (HSR 8.27.1)

1

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work (HSR 8.27.2)

1

-

-

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platfonn, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (HSR 8.28)

1

-

-

... More
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. (HSR 8.29)

1

-

-

... More
Painting top of roofs with bitumen of approved quality @ 17kg per 10 impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete With residual type petroleum bitumen of grade VG -10 (HSR 9.10.1)

1

-

-

... More
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: With common burnt clay non-modular brick tile of class designation 10 (HSR 9.11.1)

1

-

-

... More
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: With common burnt clay non-modular brick tile of class designation 10 (Based on HSR 9.11.1) Note:- Excluding the element of mud and brick tiles:- Mud and brick tiles of recovered from demonisation shall be supplied free of cost to agency for re-used.

1

-

-

... More
Providing gola 75x75 mm in cement concrete 1: 2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase (HSR 9.17.1)

1

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR 9.18)

1

-

-

... More
Providing and fixing Hi, Rib profiled sheets 0.60mm TT (Total Thickness) (only± 0.2mm tolerance allowed) Hi Tensile galvalume/Zincalume steel sheet of the approved make having a hot dip metallic Zinc-Aluminium alloy (AZ-150) coating of minimum (150 gms/sqm) with 550 Mpa yield strength of approved blue colour (RAL-5012) the colour coating shall be as per IS 15965 of SMP or Super Durable Polyester Paint XRW fixed with hex head self-drilling screw sloping roof without curvature as per approved specification, drawing and design. (HSR 9.31)

1

-

-

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing periMeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and30 mm long, the periMeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of periMeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charae but excludina the cost of oaintina with 12.5 mm thick tapered edge gypsum moisture resistant board (HSR 9.46.3)

1

-

-

... More
Providing and Fixing 15 mm thick densifled tegular edged eco friendly light weight calcium silicate false celling tiles of approved texlure of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising@ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm interval and laying 15 mm thick densifled edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixlures, smoke detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ·r, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. (HSR 9.48) Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, noncombustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/mK.

1

-

-

... More
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diaMeter (HSR 9.57.1)

1

-

-

... More
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diaMeter (HSR 9.57.2)

1

-

-

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diaMeter and weighing not less than 440 grams. (HSR 9.60)

1

-

-

... More
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)

1

-

-

... More
Providing and laying of screed of 50 mm thick cement concrete 1 :8:16 to sqm be laid below the topping. (HSR 10.4)

1

-

-

... More
Providing and laying of conglomerate floor 50mm thick cement concrete topping 1 :2:4 (HSR 10.7)

1

-

-

... More
Providing and laying of conglomerate floor 40mm thick cement concrete topping 1 :2:4 (HSR 10.8)

1

-

-

... More
Providing a floating coat of 1.50 mm thick neat cement laid in one operation to the topping. (HSR 10.14)

1

-

-

... More
Providing and laying cement concrete pavement with 1: 2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. (HSR 10.16)

1

-

-

... More
Providing and laying of brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1 :4 ( 1 cement : 4 coarse sand) (HSR 10.33.1)

1

-

-

... More
Providing and laying of flat brick or tile flooring with bricks of class designation 7 .5 laid in cement sand mortar 1 :4 on 100 mm thick cement concrete 1:8:16 and 100 mm sand filling and cement pointing 1 :2 on top. (HSR 10.35.1)

1

-

-

... More
Brick on end in soil/edging in required pattern with bricks of class designation (HSR 10.36)

1

-

-

... More
Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand) : 25 mm thick (HSR10.37.1 )

1

-

-

... More
Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (HSR 10.38)

1

-

-

... More
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. (HSR 10.42)

1

-

-

... More
Providing and fixing granite stone in all shades 15mm to 18 mm thick in sqm skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1 :3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. (HSR 10.51)

1

-

-

... More
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.58)

1

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1 :4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. (HSR 10.59)

1

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (HSR 10.63.2)

1

-

-

... More
Deduct for not using 20 mm thick cement mortar 1 :4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm (HSR 10.64)

1

-

-

... More
Providing and fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness (HSR 10.65)

1

-

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (HSR 10.67.2)

1

-

-

... More
Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.06% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm (HSR 10.71.2)

1

-

-

... More
Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles (HSR 10.72)

1

-

-

... More
Providing and fixing of P.V.C. sheet flexible type conforming to I.S.3462-1966 flooring plain coloured marble or mottled finish on a smooth damp proof base laid with adhesive recommended by manufacturer including pressing the sheet with a suitable tool to get a smooth surface all complete as directed by the Engineer-in-Charge. 2.00 mm thick (HSR 10.82.2)

1

-

-

... More
Providing and fixing of gun metal cramps 15 mm x 6 mm, 16.5 cm long as per design including cost of mortar. (HSR 10.90)

1

-

-

... More
Providing and fixing of copper pins 7.5 cm long of 6mm diaMeter including cost of mortar. (HSR 10.91)

1

-

-

... More
Cement Concrete 1:8:16 with stone aggregate 40 mm size in cum foundation and plinth. (HSR 10.100.2)

1

-

-

... More
Mirror polishing on marble work/Granite work/stone work whereever reqired sqm 243 45 288 to give high gloss finish complete. (HSR 10.104)

1

-

-

... More
Providing and laying matt finished vitrified tile of size 300x300x9.8mm having sqm 249 834 1082 with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1 :4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. (HSR 10.106)

1

-

-

... More
10 mm thick cement plaster 1 :3 (1 cement: 3 fine sand) (HSR 11.4.2)

1

-

-

... More
12 mm cement plaster of mix : 1 :4 (1 cement: 4 fine sand) (HSR 11.5.3)

1

-

-

... More
12 mm cement plaster of mix : 1 :6 (1 cement: 6 fine sand) (HSR 11.5.4)

1

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1 :4 (1 cement: 4 fine sand) (HSR 11.6.1)

1

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1 :6 (1 cement: 6 fine sand) (HSR 11.6.2)

1

-

-

... More
20 mm cement plaster of mix 1 :4 ( 1 cement: 4 coarse sand) (HSR 11.10.1)

1

-

-

... More
20 mm cement plaster of mix 1 :6 (1 cement: 6 coarse sand) (HSR 11.10.2)

1

-

-

... More
Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge. (HSR 11.17)

1

-

-

... More
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1 :5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1 :3 (1 cement : 3 coarse sand) finished rough with sponge. (HSR 11.20)

1

-

-

... More
Pointing on brick work or brick flooring with cement mortar 1 :3 (1 cement : 3 fine sand): Flush / Ruled/ Struck or weathered pointing (HSR 11.25.1)

1

-

-

... More
Pointing on tile brick work with cement mortar 1 :3 (1 cement : 3 fine sand): Flush/ Ruled/ Struck or weathered pointing (HSR 11.26.1 )

1

-

-

... More
Cement rendering on plaster 1 mm thick (HSR 11.52)

1

-

-

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. (HSR 11.59)

1

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (HSR 11.60)

1

-

-

... More
Distempering with 1st quality acrylic distemper (ready mixed) having voe content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work (HSR 11.65.1)

1

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer (HSR 11.67.1)

1

-

-

... More
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works (HSR 11.68.3)

1

-

-

... More
Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work (HSR 11. 71.1)

1

-

-

... More
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 11.76)

1

-

-

... More
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)

1

-

-

... More
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)

1

-

-

... More
Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 litre/10 sqm) over (HSR 11.94.1)

1

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (HSR 11.95.1)

1

-

-

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately} 12.7.2 Kiln seasoned and chemically treated Hollock wood 30 mm thick shutters (HSR 12.7.2.2)

1

-

-

... More
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISi marked M.S. pressed butt hinges bright finished of required size with necessary screws. Kiln seasoned and chemically treated Hollock wood 30 mm thick (HSR 12.10.2.2)

1

-

-

... More
Providing & Fixing decorative high pressure laminated sheet of plain/ wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.5 mm thick (HSR 12.12.1)

1

-

-

... More
Providing & Fixing decorative high pressure laminated sheet of plain/ wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick (HSR 12.12.2)

1

-

-

... More
Providing and fixing wire gauge laminated veneer lumber shutters conforming to IS : 14616, using galvanised wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm as per IS :1568, for doors, windows and clerestory windows, including ISi marked M.S. pressed butt hinges bright finished of required size with necessary screws, as per directions of Engineer-in-charge: (Note:- Butt hinges and necessary screws shall be paid separately) 30 mm thick shutters (HSR 12.20.2)

1

-

-

... More
Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including llnd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge. With non decorative veneering on both sides (HSR 12.31.2)

1

-

-

... More
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISi marked Stainless Steel butt hinges with sqm necessary screws (HSR 12.37.1)

1

-

-

... More
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 25 mm thick (for cupboard) including ISi marked nickel plated bright finished M.S. piano hinges with necessary screws. (HSR 12.37.3)

1

-

-

... More
Providing M.S. Piano hinges ISi marked IS: 3818 finished with nickel plating and fixing with necessary screws etc., complete. Overall width 35 mm (HSR 12.57.1)

1

-

-

... More
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 356 4, embossed on the body, door weight up to 35 kg and door width up to 7 00 mm), with necessary accessories and screws etc. complete. (HSR 12.88)

1

-

-

... More
Providing and fixing aluminium e xtruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS: 3564, embossed on the body, door weight up to 3 6 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. (HSR 12.89)

1

-

-

... More
Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Size 40 mm (HSR 12.92.1)

1

-

-

... More
Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete (HSR 12.93)

1

-

-

... More
Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm (HSR 12.98.1)

1

-

-

... More
Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm (HSR 12.98.2 )

1

-

-

... More
Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 300x10 mm (HSR 12.99.1)

1

-

-

... More
Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 250x10 mm (HSR 12.99.2)

1

-

-

... More
Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 200x10 mm (HSR 12.99.3)

1

-

-

... More
Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 125 mm (HSR 12.102.1)

1

-

-

... More
Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 100 mm (HSR 12.102.2)

1

-

-

... More
Providing and fixing aluminium hanging floor door stopper, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper (HSR 12.103.1)

1

-

-

... More
Providing and fixing aluminium hanging floor door stopper, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper (HSR 12.103.2 )

1

-

-

... More
Providing and fixing aluminium casement stays, ISi marked, anodised transparent or dyed to required colour and shade or powder coated or polyester powder coated, with necessary screws etc. complete Anodized (AC-15) Aluminium (HSR 12.104.2)

1

-

-

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISi marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. (HSR 12.105)

1

-

-

... More
Providing Aluminium Jali of thickness 7mm thick with openings - 75mm X 75mm of including anodizing and fixing in frame with cost of screws etc. (HSR 12.107)

1

-

-

... More
Providing fixing aluminium round shape handle of outer dia 100mm with screws etc. complete. Anodized (AC-15) Aluminium (HSR 12.108.1)

1

-

-

... More
Providing fixing aluminium round shape handle of outer dia 100mm with screws etc. complete. Powder coated minimum thickness 50 micron (HSR 12.108.2)

1

-

-

... More
Providing and fixing of roller blinds on windows complete with material and labour complete with push up & down arrangement as per approved design /colour and Engineer-in-charge. (HSR 12.114)

1

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) (HSR 12.157.1.2)

1

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Zsections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron(HSR 12.157.2.2 )

1

-

-

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side (HSR 12.158.1)

1

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (HSR 12.159.2 )

1

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 6 mm thickness (weight not less than 15 kg/sqm) (HSR 12.159.3)

1

-

-

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness (HSR 12.160.1)

1

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). (HSR 12.171)

1

-

-

... More
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge. (HSR 12.173)

1

-

-

... More
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size). (HSR 13.1.1 )

1

-

-

... More
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (HSR 13.1.2)

1

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb (HSR 13.3.1.1)

1

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C Fixing with adjustable lugs with split end tail to each jamb (HSR 13.3.2.1)

1

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile E Fixing with adjustable lugs with split end tail to each jamb (HSR 13.3.3.1 )

1

-

-

... More
Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) (HSR 13.7.1)

1

-

-

... More
Providing and fixing factory made ISi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) (HSR 13.8.1 )

1

-

-

... More
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M .S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides (HSR 13.9.1)

1

-

-

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes (HSR 13.10.1)

1

-

-

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 5.5 mm thick glass panes (HSR 13.10.2)

1

-

-

... More
Extra for providing and fixing steel beading of MS flat of size 20mm x 3mm section For doors (HSR 13.12.1)

1

-

-

... More
Extra for providing and fixing steel beading of MS flat of size 20mm x 3mm section For windows (HSR 13.12.2 )

1

-

-

... More
Providing and fixing hard drawn steel wire fabric 75 mm X 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled sections with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect (HSR 13.18)

1

-

-

... More
Providing and fixing galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm fixed on steel windows of standard rolled steel section, with 3 mm thick MS flat iron cover moulding of 12.5 mm width, fixed with machine screws welded complete in all respects. (HSR 13.19)

1

-

-

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (HSR 13.27)

1

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(HSR 13.28)

1

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete (HSR 13.29.1)

1

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (HSR 13.29.2)

1

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes (HSR 13.30.1)

1

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1 .20 mm M.S. laths with 1.20 mm thick top cover (HSR 13.37.2)

1

-

-

... More
Providing and fixing ball bearing for rolling shutters. (HSR 13.38)

1

-

-

... More
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and up to 16.80 sqm in the area (HSR 13.39.1)

1

-

-

... More
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 16.80 sqm in area (HSR 13.39.2)

1

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (HSR 13.41)

1

-

-

... More
Water Bound Macadam Gr I Water Bound Macadam Grading I with screening Type 'A' Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-1 0 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications. (HSR 17.22.2)

1

-

-

... More
Water Bound Macadam Grading -II Water Bound Macadam - II with Screening Type 'A' / Type B Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-1 0 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications. (HSR 17.23.2)

1

-

-

... More
Tack Coat Providing and applying tack coat with penetration grade bitumen VG - 10 using bitumen pressure distributor at the rate of 0.30 kg per sqm on the prepared bituminous/ granular surface cleaned with mechanical broom as per technical clause 503 of MORT&H specifications. (HSR 17.26.2)

1

-

-

... More
Built-up-Spray Grout Providing, laying and rolling of built-up-spray grout layer over prepared base consisting of a two layer composite construction of compacted crushed coarse aggregates using motor grader for aggregates. key stone chips spreader may be used with application of bituminous binder after each layer, and with key aggregates placed on top of the second layer to serve as a Base conforming to the line, grades and cross-section specified, the compacted layer thickness being 75mm Nota: - 2 tippers will be needed to match the capacity of hydraulic chip spreader and front end loader. (HSR 17.29)

1

-

-

... More
Surface Dressing Providing and laying surface dressing as wearing course in single coat using crushed stone aggregates of specified size on a layer of bituminous binder VG - 10 laid on prepared surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 509 of MORT&H specifications 19 mm nominal chipping size, with bitumen (HSR 17.32.1)

1

-

-

... More
Open - Graded Premix Surfacing 20 mm U,ickness Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of crushed stone aggregates of specified grading premixed in a continuous type of hot mix plant of appropriate capacity not less not less than 75 tonne per hour, with bituminous binder VG - 10 @ 1.46 kg per sqm, laid with Paver Finisher Mechanical and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades complete as per technical clause 510 of MORT&H specifications (HSR 17.33.1)

1

-

-

... More
Type B with VG -10 bituminous binder Providing and laying of premix sand seal coat premixed in continuous type HMP of appropriate capacity not less than 75 tonnes/ hours using specified fine aggregates and penetration grade bitumen @0.68 kg/sqm laid to specified levels, grade and cross fall complete as per technical clause 511 of MORT&H specifications. (HSR 17.36.3)

1

-

-

... More
Patch Work with close graded Premix Surfacing/Mixed seal Surfacing 20 mm thickness (Type B) Providing and laying patch work with close graded premixed surfacing material of 20 mm thickness Type B using penetration grade Bitumen VG - 10 @ 1.9 kg per sqm and crushed aggregates of specified grading after trimming the pot holes, removal of failed material, including mixing in a continuous type of HMP, carriage of mixed material and rolling with a smooth wheeled roller to match the adjoinin surface complete as per technical clause 508 of MORT&H specifications. (HSR 17.50)

1

-

-

... More
Providing and laying of premix sand seal coat premixed in continuous type HMP of appropriate capacity not less than 75 tonnes/ hours using specified fine aggregates and penetration grade bitumen @0.68 kg/sqm laid to specified levels, grade and cross fall complete as per technical clause 511 of MORT&H specifications. (HSR 17.51)

1

-

-

... More
Removing of existing CC block pavement including transporting and stacking usable block along road side and dispose unusable blocks outside PWD land or desired by Engineer.. (HSR 17.67)

1

-

-

... More
Relaying of available (removed and stacked) C.C. Block M-30 Size 450x300x150mm and spreading 25 mm thick sand underneath filling joints with sand as per technical specification clause 1503. (HSR 17.68)

1

-

-

... More
Providing and Laying 80 mm thick ISi marked lntertocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect. (HSR 17.69.2)

1

-

-

... More
Providing and Laying 60 mm thick ISi marked lntertocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 35 over the bed of 25 mm thick fine sand complete in all respect. (HSR 17.69.3)

1

-

-

... More
Relaying of available (removed and stacked) Interlocking Paver Block Pavement having thickness 100 mm/80 mm/ 60 mm (average = 80mm) as per drawings and TechnicalSpecification Clause 1504 (HSR 17.71)

1

-

-

... More
Providing and applying two coats of Dr. Fixit Pidicrete URP – SBR Latex (Pidilite make) solution made of URP + cement in the proportion of 1:1.5 (as recommended by the manufacturer) on deteriorated concrete surfaces of slab and columns, complete in all respects as directed by the Engineer-in-Charge. (NS)

1

-

-

... More
Earth filling under floors/road/along with boundary wall/in open area with dune sand (tiba sand), brought from outside (any lead), in 15 cm layer including laying, dressing, watering ramming, consolidating, excavation, carriage, loading, unloading and compensation, etc., complete (NS)

1

-

-

... More
Providing and fixing planking of 19 mm thick wood polymer cellka board (ISI mark) of approved make in cupboards including cutting, nails and screws, etc., fixed in position, complete in all respects as per drawing and design. (NS)

1

-

-

... More
Providing and fixing PVC wall panelling consisting of 7mm thick hollow PVC section of Cactus or any other equivalent make Super Heavy (as approved by Engineer-in-Charge) PVC U-section beading of size 25mm x 8mm x 12mm and PVC angle nosing of size 25mm x 25mm x 1.5mm of Cactus or any other equivalent make (as approved by Engineer-in-Charge) including cost of PVC gutties, screws, jointed with polyfix (instant glue), complete in all respects as per drawing or as directed by Engineer-in-Charge. (NS)

1

-

-

... More
Scraping of brick tiles of size 22.86 cm x 11.43 cm x 3.81 cm in cement mortar, complete (NS)

1

-

-

... More
Removing of existing false ceiling tiles at all height (ceiling tiles only) of size 60 cm x 60 cm x 12 mm thick of teak wood particle board and plain board in boarder (to be removed carefully), complete in all respects as directed by Engineer-in-Charge. (NS)

1

-

-

... More
Fixing of old false ceiling tiles at all height (ceiling tiles only) of size 60 cm x 60 cm x 12 mm thick of teak wood particle board in existing aluminium tee frame (excluding aluminium tee frame) properly maintaining 3/8” wide grooves including proper opening for light fittings, cost of screws, nails, rawl plugs, primer and painting etc. complete in all respects as directed by Engineer-in-Charge. (Note: - false ceiling tiles will be supplied by the department free of cost). (NS)

1

-

-

... More
Tacking (making rough) the exposed reinforced cement concrete surface for cement plaster (horizontal and vertical surface) including removing of loose concrete, disposing off the malba and cleaning the surface etc., complete in all respect as directed by Engineer-in-Charge. (NS)

1

-

-

... More
Providing and fixing 100 mm wide vertical venetian blinds of required size and shape ( Vista make select range), fixed in position including rawl plugs and screws, etc., complete in all respects as per drawing and design. (NS)

1

-

-

... More
Providing and fixing marble strips of size 14 mm to 17 mm thick and 40 mm wide in cement concrete/ terrazzo flooring fixed in position, complete in all respects as per drawing and design or as directed by Engineer-in-Charge. (NS)

1

-

-

... More
Providing and fixing marble strips of size 14 mm to 17 mm thick and 90 mm wide in cement concrete/ terrazzo flooring fixed in position, complete in all respects as per drawing and design or as directed by Engineer-in-Charge. (NS)

1

-

-

... More
Providing and fixing vitrified tiles of size 1200 x 600 mm of approved make in skirting laid in any patterns as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles (NS) Notes: i. Tile shall be premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, JOHNSONS, RAK, ORIENT BELL & SIMPOLO. ii. Tiles shall be fixed by using PVC spacers of required size and the space between tiles shall be filled up with cement based grout of approved make & colour. Nothing extra shall be paid for this.

1

-

-

... More
Providing and fixing factory manufactured cement concrete 1:2:4 kerb finished smooth and of size 1’-0” x 1’-0” x 0’-6” of required shape and design fixed at ground level along with road, complete in all respect as directed by the Engineer-in-Charge but excluding cost of cement pointing. (NS)

1

-

-

... More
Providing and fixing factory manufactured cement concrete 1:2:4 channel finished smooth and of size 1’-0” x 1’-0” x 0’-3” of required shape and design fixed at ground level along with road, complete in all respect as directed by the Engineer-in-Charge but excluding cost of cement pointing. (NS)

1

-

-

... More
Providing and fixing Glass Accessories i.e. handle of size 600 mm x 30 mm of DORMA make (Model XL-C-3004 ) including cost of stainless steel screws etc. complete in all respect as directed by Engineer-In-charge. (NS)

1

-

-

... More
Providing and fixing at all height, fiber glass sheets of approved colour on steel trusses/ frame (excluding cost of frame) including nuts, bolts, screws and bitumen washer etc. fixed in position, complete in all respect as per architectural drawing and design. (NS)

1

-

-

... More
Providing and fixing G.I. barbed wire fencing, weighing 13.60 kg to 15.50 kg per 100 metres (Horizontal/ diagonal )and fixed with G.I. wire of 12 gauge or by providing cut including drilling holes in the posts, complete in all respects as directed by Engineer-in-Charge (including the cost of G.I. wire used for binding which shall not be measured for payment but excluding the cost of posts, struts, earth work and concrete which is payable extra) (NS)

1

-

-

... More
Providing and fixing G.I. barbed wire fencing, weighing 13.60 kg to 15.50 kg per 100 metres (Horizontal/ diagonal) and fixed with G.I. hooks by means of G.I. wire of 12 gauge in the RCC posts, complete in all respects as directed by Engineer-in-Charge (including the cost of G.I. wire used for binding which shall not be measured for payment but excluding cost of RCC posts, G.I. hooks and cement concrete blocks which are payable separately.) (NS)

1

-

-

... More
Providing and fixing 8 gauge G.I. wire for making rings for reinforced concrete posts including bending, binding and placing in position, complete ( NS )

1

-

-

... More
Providing and fixing 0’-4” long M.S. pipe of ¾” dia (middle class) embedded in RCC posts, complete in all respects as per architectural drawing and design. (NS)

1

-

-

... More
Providing and fixing G.I. interlocking fencing of size 3”x 3” or any other size made of 10 gauge wire fixed with RCC post by means of M.S. flat & bolts/ nuts (Items of M.S. flat and bolts/ nuts shall be paid separately under HSR) including drilling holes in M.S. flats etc., complete in all respects as per architectural drawing and design. (NS)

1

-

-

... More
Providing and fixing 8 mm thick plain bison panel of approved make in cabinet shutter/duct in frame (cost of frame and moulding/beading shall be paid separtely) fixed with machine screws including cutting, drilling holes, etc., complete in all respects as per architectural drawing and design (NS)

1

-

-

... More
Removing of existing precast cement concrete kerbs (to be removed carefully) from road/path/plinth protection and shifting the same to maintenance store, complete in all respects as directed by the Engineer-in-Charge. (NS)

1

-

-

... More
Removing of existing precast cement concrete channels (to be removed carefully) from road/path/plinth protection and shifting the same to maintenance store, complete in all respects as directed by the Engineer-in-Charge. (NS)

1

-

-

... More
Fixing of existing precast cement concrete kerbs in path/road/plinth protection, complete in all respects as directed by the Engineer-in-Charge (old kerbs will be supplied by the department free of cost). (NS)

1

-

-

... More
Fixing of existing precast cement concrete channels in path/road/plinth protection, complete in all respects as directed by the Engineer-in-Charge (old channels will be supplied by the department free of cost). (NS)

1

-

-

... More
Providing and fixing concertina spiral GI wire fencing of 1'-6"/2'-0" dia or any other dia on Y-shape angle iron posts & barbed wire fencing (excluding cost of angle iron post & barbe wire fencing) weighing 150-160 kg per 100 metre, (of Make as approved by Engineer-in-Charge and confirming to IS specifications) fixed with plain GI wire of 16 gauge, complete in all respect as directed by Engineering Incharge (plain GI wire used for binding shall not be measured for payment). (NS)

1

-

-

... More
Providing and fixing 6 mm thick High Pressure Laminated (HPL) sheets, at all height of Green, Century Alstone or Sundrek of approved colour fixed on aluminium tube frame of size 25 mm x 38.10 mm x 2.00 mm @ of 2'-0'' C/C on wall cladding including sealent, tape, rawl plugs, nails, screws etc. complete in all respects as per drawing and design (NS)

1

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass of AIS/Modi/Guard/Saint Gobin make dully toughened by standarized plant with required holes and cut out for openable door shutter including providing and fixing top & botom pivot, complete in our respect as per direction of Engineering In-Charge. (Door Handle, Floor machine etc. to be paid separately. (NS)

1

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass of AIS/Modi/Guard/Saint Gobin make dully toughened by standarized plant with required holes and cut out for fixed partition including cost of top & botom stainless steel profile of required size, complete in all respect as per architectural drawing and design or as directed by Engineering In-Charge. (NS)

1

-

-

... More
Profixing and fixing Glass Accessories i.e. glass door package with lock (floor machine) of DORMA make (Model XL-C-4001 B) including cost of stainless steel screws etc. complete in all respect as directed by Engineer-In-Charge. (NS)

1

-

-

... More
Providing and fixing frosted lining film of approved make, shade and colour, fixed in position on toughened glass including making design/pattern as per architectural drawing & design, complete in all respects. (NS)

1

-

-

... More
Providing and fixing 3 mm thick wooden texture aluminium composite panels (ACP) of ALSTONE or ALUDECORE make of approved colour fixed on aluminium tube frame of size 50mm x 25 mm x 2.0mm @ 2’-0” c/c (horizontal/vertical as required), including sealent, tape, nails, screws etc. complete in all respects as per drawing and design. (NS)

1

-

-

... More
Uprooting of pipal trees (with entire roots by digging/forking the area) and vegeation, grass etc. from terrace (Flat surface) locations of the building and making good the area (i.e. repairing tile terracing, brick work etc.) and disposal of rubbish to all leades complete including all tool and plants, taxes etc. required to complete the job complete as directed and upto the entire satisfaction of Engineer In-Charge. Pipal plant of Grith From 2' to up to 5" whorse root impact area of 6 sqft approx. (NS)

1

-

-

... More
Uprooting of pipal trees (with entire roots by digging/forking the area) and vegeation, grass etc. from elevation face (outer wall areas at all heights) locations of the building and making good the area, proper injection of harbicide to root area and disposal of rubbish to all leads complete including all tools and plants, scafolding, taxes etc. required to complete the job complete as directed and up to the satisfaction of Engineer In charge. Plant having any girth ranging from 1" upto any grith having root impact area of 1 SQM (NS)

1

-

-

... More
Uprooting of pipal trees (with entire roots by digging/forking the area) and vegeation, grass from terrace (flat surface) locations of the building and making good the area (i.e. repairing tile terracing, brick work etc.) and disposal of rubbish to all leads complete including all tool and plants, taxes etc. required to complete the job complete as directed and up to the entire satisfaction of Engineer In charge. Pipal plant of Grith up to 2" whose root impact area of 2.25 sqft approx. (NS)

1

-

-

... More
Public Health work 217 to 376:- Extra for fixing and jointing union couplings in G.I. and W.I. pipelines 15 mm internal diameter (HSR 20.23.1)

1

-

-

... More
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines 20 mm internal diameter (HSR 20.23.2)

1

-

-

... More
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines 25 mm internal diameter (HSR 20.23.3)

1

-

-

... More
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines 32 mm internal diameter (HSR 20.23.4)

1

-

-

... More
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines 40 mm internal diameter (HSR 20.23.5)

1

-

-

... More
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required 11.43 cm thick wall (HSR 20.26.1)

1

-

-

... More
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required 22.86 cm thick wall (HSR 20.26.2)

1

-

-

... More
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required 34.29 cm thick wall (HSR 20.26.3)

1

-

-

... More
Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repainting, replastering, replacing bitumen and colour or white washing where required 75 mm thickness of roof or floor (HSR 20.28.1)

1

-

-

... More
Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repainting, replastering, replacing bitumen and colour or white washing where required. 115 mm thickness of roof or floor (HSR 20.28.2)

1

-

-

... More
Cutting holes up to 23 cm square for pipes in floor and roofs of cement concrete reinforced concrete or reinforced brick work and making good including, repainting, replastering, replacing bitumen and colour or white washing where required. 150 mm thickness of roof or floor (HSR 20.28.3)

1

-

-

... More
Dismantling disjointing, removal and carriage to stores, G.I. pipelines, specials, valves and fittings. 15 mm internal diametre of the pipeline (HSR 20.50.1)

1

-

-

... More
Dismantling disjointing, removal and carriage to stores, G.I. pipelines, specials, valves and fittings. 20 mm internal diametre of the pipeline (HSR 20.50.2)

1

-

-

... More
Dismantling disjointing, removal and carriage to stores, G.I. pipelines, specials, valves and fittings. 25 mm internal diametre of the pipeline (HSR 20.50.3)

1

-

-

... More
Dismantling disjointing, removal and carriage to stores, G.I. pipelines, specials, valves and fittings. 32 mm internal diametre of the pipeline (HSR 20.50.4)

1

-

-

... More
Dismantling disjointing, removal and carriage to stores, G.I. pipelines, specials, valves and fittings. 40 mm internal diametre of the pipeline (HSR 20.50.5)

1

-

-

... More
Making connection with the existing G.I. branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site (HSR 20.36)

1

-

-

... More
Providing & fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS: 1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1 :2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge (HSR 21.28)

1

-

-

... More
Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1 :5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benchingb 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neat cement R.C.C. 1 :2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C.topping (HSR 21.84.1)

1

-

-

... More
Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) (HSR 21.84.2)

1

-

-

... More
Extra for every 0.30 metre depth of Inspection chamber 450 mm x 450 mm inside (HSR 21.85.1)

1

-

-

... More
Extra for every 0.30 metre depth of Inspection chamber 450 mmx 600 mm inside (HSR 21.85.2)

1

-

-

... More
Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1 :3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening (HSR 21.93.1)

1

-

-

... More
Providing salt glazed stone ware pipes grade 'A' in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 induding the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. (HSR 21.94.1) 100mm i/d

1

-

-

... More
Providing salt glazed stone ware pipes grade 'A' in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 induding the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. 150mm i/d (HSR 21.94.2)

1

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White vitreous chinaware Wash basin size 630x450 mm with a pair of 15 mm C. P. brass pillar taps (HSR 22.1.1)

1

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White vitreous chinaware Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap (HSR 22.1.2)

1

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White vitreous chinaware Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (HSR 22.2.1)

1

-

-

... More
Providing and fixing white vitreous chinaware pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. (HSR 22.5)

1

-

-

... More
Providing and fixing white vitreous chinaware laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 450x300x150 mm (HSR 22.6.1)

1

-

-

... More
Providing and fixing white vitreous chinaware laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm (HSR 22.6.2)

1

-

-

... More
Providing and fixing white vitreous chinaware laboratory sink including making all connections excluding cost of fittings : Size 450x300x150 mm (HSR 22.7.1)

1

-

-

... More
Providing and fixing white vitreous chinaware laboratory sink including making all connections excluding cost of fittings : Size 600x450x200 mm (HSR 22.7.2)

1

-

-

... More
Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). One way (HSR 22.8.1)

1

-

-

... More
Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). Two way (HSR 22.8.2)

1

-

-

... More
Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board 610x460 mm bowl depth 200 mm (HSR 22.10.2.2)

1

-

-

... More
Providing and fixing CP Brass Single lever telephonic wall mixer of quality &make as approved by Engineer in charge. 15 mm nominal dia (HSR 22.12.1)

1

-

-

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia (HSR 22.14.2.1)

1

-

-

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia (HSR 22.14.2.2)

1

-

-

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (HSR 22.15)

1

-

-

... More
Providing and fixing 40mm i/d G.I. waste pipe embedded in walls up to floor level including cost of union and plumber joint. (HSR 22.16)

1

-

-

... More
Providing and fixing 40mm i/d chromium plated trap with chromium plated pipe to wall with walflange completed for use with sinks With Bottle Trap (Indian make) (HSR 22.17.1)

1

-

-

... More
Providing and fixing 100 mm sand cast Iron grating for gully trap. (HSR 22.19)

1

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (HSR 22.22.1)

1

-

-

... More
Providing and fixing white vitreous chinaware pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISi marked white solid plastic seat and lid (HSR 22.23.1 )

1

-

-

... More
Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required 2 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern (HSR 22.26.1)

1

-

-

... More
Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern (HSR 22.26.3)

1

-

-

... More
Providing and fixing white vitreous chinaware water closet squatting pan (Indian type):- Orissa pattem W.C. pan of size 580x440 mm (HSR 22.28.2)

1

-

-

... More
Providing and fixing white vitreous chinaware pedestal type (European type/ wash down type) water closet pan. (HSR 22.30)

1

-

-

... More
Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (HSR 22.33)

1

-

-

... More
Providing and fixing floor mounted, white vitreous chinaware single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous chinaware cistern of capacity10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. (HSR 22.34)

1

-

-

... More
Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete: White solid plastic seat with lid (HSR 22.36.1)

1

-

-

... More
Providing and fixing 8 mm dia C.P.S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. (HSR 22.38)

1

-

-

... More
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White (HSR 22.39.1)

1

-

-

... More
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity- coloured (HSR 22.39.2)

1

-

-

... More
Providing and fixing toilet paper holder C.P. brass (HSR 22.42.1)

1

-

-

... More
Providing and fixing toilet paper holder Vitreous chinaware (HSR 22.42.2)

1

-

-

... More
Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (HSR 22.46)

1

-

-

... More
Providing and fixing partitions for different type of urinals. Small size 680mm x 330 mm White (HSR 22.50.1.1.1)

1

-

-

... More
Large size 835mm x 355 mm White (HSR 22.50.1.2.1)

1

-

-

... More
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 75 mm outlet Sand cast iron S&S as per IS - 3989 (HSR 22.80.2.1)

1

-

-

... More
Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1 :3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1 :4 (1 cement : 4 coarse sand) 100 mm dia (HSR 22.81.1)

1

-

-

... More
Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1 :3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1 :4 (1 cement : 4 coarse sand) 75 mm dia (HSR 22.81.2)

1

-

-

... More
Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1 :3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1 :4 (1 cement : 4 coarse sand) 50 mm dia (HSR 22.81.3)

1

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia Pipes (HSR 22.85.1)

1

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal outer dia Pipes (HSR 22.85.2)

1

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes (HSR 22.85.3)

1

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal outer dia Pipes (HSR 22.85.4)

1

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal outer dia Pipes (HSR 22.85.5)

1

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes (HSR 22.86.1)

1

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes (HSR 22.86.2)

1

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes (HSR 22.86.3)

1

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes (HSR 22.86.4)

1

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal outer dia Pipes (HSR 22.87.4)

1

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal outer dia Pipes (HSR 22.87.5)

1

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal outer dia Pipes (HSR 22.87.6)

1

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work· Exposed on wall 15 mm dia nominal bore (HSR 22.88.1)

1

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work· Exposed on wall 20 mm dia nominal bore (HSR 22.88.2)

1

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work· Exposed on wall 25 mm dia nominal bore (HSR 22.88.3)

1

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work· Exposed on wall 32 mm dia nominal bore (HSR 22.88.4)

1

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work· Exposed on wall 40 mm dia nominal bore (HSR 22.88.5)

1

-

-

... More
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore (HSR 22.89.1)

1

-

-

... More
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 20 mm dia nominal bore (HSR 22.89.2)

1

-

-

... More
Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. (HSR 22.90)

1

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc External work 25 mm dia nominal bore (HSR 22.91.3)

1

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc External work 32 mm dia nominal bore (HSR 22.91.4)

1

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc External work 40 mm dia nominal bore (HSR 22.91.5)

1

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc External work 50 mm dia nominal bore (HSR 22.91.6)

1

-

-

... More
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 15 mm nominal bore (HSR 22.94.1)

1

-

-

... More
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 20 mm nominal bore (HSR 22.94.2)

1

-

-

... More
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 25 mm nominal bore (HSR 22.94.3)

1

-

-

... More
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 32 mm nominal bore (HSR 22.94.4)

1

-

-

... More
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 40 mm nominal bore (HSR 22.94.5)

1

-

-

... More
Providing and fixing brass bib cock of approved quality: 15 mm nominal bore (HSR 22.96.1)

1

-

-

... More
Providing and fixing brass stop cock of approved quality: 15 mm nominal bore (HSR 22.97 .1)

1

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 25 mm nominal bore (HSR 22.98.1)

1

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 20 mm nominal bore (HSR 22.98.2)

1

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 32 mm nominal bore. (HSR 22.98.3)

1

-

-

... More
Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main 15 mm nominal bore (HSR 22.100.1)

1

-

-

... More
Providing and fixing Unplasticised PVC connection pipe with brass unions: 45 cm length 15 mm nominal bore (HSR 22.101.2.1)

1

-

-

... More
Providing and fixing Unplasticised PVC connection pipe with brass unions: 45 cm length 20 mm nominal bore (HSR 22.101.2.2)

1

-

-

... More
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: 100 mm diameter (HSR 22.102.1)

1

-

-

... More
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: 150 mm diameter (HSR 22.102.2)

1

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore (HSR 22.103.1)

1

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore (HSR 22.103.2)

1

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore (HSR 22.103.3)

1

-

-

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore (HSR 22.104.1)

1

-

-

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore (HSR 22.106.1)

1

-

-

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore (HSR 22.107.1)

1

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore (HSR 22.108.1)

1

-

-

... More
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (HSR 22.109)

1

-

-

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms (HSR 22.119.1)

1

-

-

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (HSR 22.119.2)

1

-

-

... More
Providing and fixing PTMT grating of approved quality and colour Circular type 100 mm nominal dia (HSR 22.123.1.1)

1

-

-

... More
Providing and fixing PTMT grating of approved quality and colour Circular type 125 mm nominal dia with 25 mm waste hole (HSR 22.123.1.2)

1

-

-

... More
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms (HSR 22.127)

1

-

-

... More
Providing and fixing C.I. sluice valves (with cap) c omplete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) 100 mm diameter Class I (HSR 22.162.1.1)

1

-

-

... More
Providing and fixing C.I. sluice valves (with cap) c omplete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) 100 mm diameter Class II (HSR 22.162.1.2)

1

-

-

... More
Providing and fixing C.I. sluice valves (with cap) c omplete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) 125 mm diameter Class I (HSR 22.162.2.1)

1

-

-

... More
Providing and fixing C.I. sluice valves (with cap) c omplete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) 125 mm diameter Class II (HSR 22.162.2.2)

1

-

-

... More
Providing and fixing C.I. sluice valves (with cap) c omplete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) 150 mm diameter Class I (HSR 22.162.3.1)

1

-

-

... More
Providing and fixing C.I. sluice valves (with cap) c omplete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) 150 mm diameter Class II (HSR 22.162.3.2)

1

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design 100 mm diameter S.W. pipe (HSR 22.165.1)

1

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design 150 mm diameter S.W. pipe (HSR 22.165.2)

1

-

-

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay non-modular bricks of class designation 7.5 (HSR 22.166.1.1)

1

-

-

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1 :4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1 :2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1 :5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1 :3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design: With common burnt clay non-modular bricks of class designation 7.5 (HSR 22.173.1)

1

-

-

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1 :4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 160 mm deep ( inside) with chained lid and RCC top slab 1 :2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 :3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay non-modular bricks of class designation 7.5 (HSR 22.174.1)

1

-

-

... More
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1 :4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1: 2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1 :3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay non-modular bricks of class designation 7.5 (HSR 22.175.1)

1

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (HSR 22.181)

1

-

-

... More
Supplying and fixing C.I. cover without frame for manholes: 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg (HSR 22.200.1)

1

-

-

... More
Supplying and fixing C.I. cover 300x300 mm without frame for gully trap each (standard pattern) the weight of cover to be not less than 4.5 kg (HSR 22.202)

1

-

-

... More
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (HSR 22.209)

1

-

-

... More
Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. C.P Brass One Way (HSR 22.212.1.1)

1

-

-

... More
Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. C.P Brass Two Way (HSR 22.212.1.2)

1

-

-

... More
Providing and fixing in position best Indian make C.P. brass Tooth Brush cumTooth Paste Holder fixed in with rawl plugs with C.P. brass screws complete including cutting and making good the walls etc. Tooth Brush-cum-Tooth Paste holder (HSR 22.213.1)

1

-

-

... More
Providing and fixing in position best Indian make C.P. brass Tooth Brush cumTooth Paste Holder fixed in with rawl plugs with C.P. brass screws complete including cutting and making good the walls etc. Toothbrush Holder (HSR 22.213.2)

1

-

-

... More
Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-incharge. 25 Litres capacity (HSR 22.216.1)

1

-

-

... More
Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-incharge. 30 Litres capacity (HSR 22.216.2)

1

-

-

... More
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. Table Top (size 49 x 40 x 15 cm) (HSR 22.221.11)

1

-

-

... More
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. Table Top square (size 39 x 39 x 15 cm) (HSR 22.221.13)

1

-

-

... More
Supply of CPVC Union couplings with brass internal fittings, complete in all respect. (NS) For 20 mm nominal outer dia Pipes

1

-

-

... More
Supply of CPVC Union couplings with brass internal fittings, complete in all respect. (NS) For 25 mm nominal outer dia Pipes

1

-

-

... More
Supply of CPVC Union couplings with brass internal fittings, complete in all respect. (NS) For 32 mm nominal outer dia Pipes

1

-

-

... More
Supply of CPVC Union couplings with brass internal fittings, complete in all respect. (NS) For 40 mm nominal outer dia Pipes

1

-

-

... More
Supply of CPVC ball valves with brass internal fittings, complete in all respect. (NS) For 20 mm nominal outer dia Pipes

1

-

-

... More
Supply of CPVC ball valves with brass internal fittings, complete in all respect. (NS) For 25 mm nominal outer dia Pipes

1

-

-

... More
Supply of CPVC ball valves with brass internal fittings, complete in all respect. (NS) For 32 mm nominal outer dia Pipes

1

-

-

... More
Supply of CPVC ball valves with brass internal fittings, complete in all respect. (NS) For 40 mm nominal outer dia Pipes

1

-

-

... More
Supply and fixing of PVC floor traps (Heavy duty) of 90 mm o/dia outlet of Prince /Supreme/Skipper make, complete in all respect. (NS)

1

-

-

... More
Supply and fixing of PVC gully traps (Heavy duty) of 100 mm dia size ( 4") with cover and frame of Prince/Supreme/skipper make complete in all respect. (NS)

1

-

-

... More
Providing and fixing PVC specials of Prince/Supreme/Skipper make of following sizes. (NS) (a) 100 mm i/dia (i) HR Bend

1

-

-

... More
Providing and fixing PVC specials of Prince/Supreme/Skipper make of following sizes. (NS) (a) 100 mm i/dia (ii) Door Tee 4" x 4" x4"

1

-

-

... More
Providing and fixing PVC specials of Prince/Supreme/Skipper make of following sizes. (NS) (a) 100 mm i/dia (iii) Elbow

1

-

-

... More
(iv) Plain Tee 4" x 4" x4"

1

-

-

... More
(v) Cowl

1

-

-

... More
(b) 80 mm i/dia (i) HR Bend

1

-

-

... More
(ii) Door Tee 3" x 3" x3"

1

-

-

... More
(iii) Elbow

1

-

-

... More
(iv) Plain Tee 3" x 3" x3"

1

-

-

... More
(v) Cowl

1

-

-

... More
Electrical works 376 to 612:- COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS --- ---- ---------- Wiring for Light/Fan/call bell point with modular type switch/socket and GIbox, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copperconductor cable in 1.6 mm thick MS conduit pipe. Group A (HSR 23.2.1.1)

1

-

-

... More
Wiring for Light/Fan/call bell point with modular type switch/socket and GIbox, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copperconductor cable in 1.6 mm thick MS conduit pipe. Group B (HSR 23.2.1.2)

1

-

-

... More
Wiring for Light/Fan/call bell point with modular type switch/socket and GIbox, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copperconductor cable in 1.6 mm thick MS conduit pipe. Group C (HSR 23.2.1.3)

1

-

-

... More
Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , includingproviding 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 AmpModular type switch required GI Box ,modular face plate etc complete asrequired Group A (HSR 23.2.4.1)

1

-

-

... More
Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , includingproviding 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 AmpModular type switch required GI Box ,modular face plate etc complete asrequired Group B (HSR 23.2.4.2)

1

-

-

... More
Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , includingproviding 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 AmpModular type switch required GI Box ,modular face plate etc complete asrequired Group C (HSR 23.2.4.3)

1

-

-

... More
Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling ,including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16Amp Modular switch required GI Box , modular face plate etc complete asrequired Group A (HSR 23.2.5.1)

1

-

-

... More
Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling ,including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16Amp Modular switch required GI Box , modular face plate etc complete asrequired Group B (HSR 23.2.5.2)

1

-

-

... More
Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling ,including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16Amp Modular switch required GI Box , modular face plate etc complete asrequired Group C (HSR 23.2.5.3)

1

-

-

... More
Wires and Cables ;-Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.1)

1

-

-

... More
Wires and Cables ;-Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.2)

1

-

-

... More
Wires and Cables ;-Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.3.6.3)

1

-

-

... More
Wires and Cables ;-Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) (HSR 23.3.6.4)

1

-

-

... More
Wires and Cables ;-Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required.1 run of Size 10 Sqmm(1/3.50 mm) (HSR 23.3.6.5)

1

-

-

... More
Wires and Cables ;-Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.6)

1

-

-

... More
Wires and Cables ;-Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.7)

1

-

-

... More
Wires and Cables ;-Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 2 run of Size 4 Sqmm(1/2.24mm) (HSR 23.3.6.8)

1

-

-

... More
Wires and Cables ;-Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 3 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.3.6.9)

1

-

-

... More
Wires and Cables ;-Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 3 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.3.6.10)

1

-

-

... More
COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A (HSR 23.4.1.1)

1

-

-

... More
COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B (HSR 23.4.1.2)

1

-

-

... More
COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C (HSR 23.4.1.3)

1

-

-

... More
Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group A (HSR 23.4.3.1)

1

-

-

... More
Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group B (HSR 23.4.3.2)

1

-

-

... More
Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group C (HSR 23.4.3.3)

1

-

-

... More
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A (HSR 23.4.4.1)

1

-

-

... More
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group B (HSR 23.4.4.2)

1

-

-

... More
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C (HSR 23.4.4.3)

1

-

-

... More
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A (HSR 23.4.5.1)

1

-

-

... More
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group B (HSR 23.4.5.2)

1

-

-

... More
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C (HSR 23.4.5.3)

1

-

-

... More
Wiring only in 1.5 sqmm PVC insulated copper conductor cable forLIGHT/FAN/Call bell point in existing conduit pipe and MS boxes includingcost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connectoretc. Group A (HSR 23.5.1.1)

1

-

-

... More
Wiring only in 1.5 sqmm PVC insulated copper conductor cable forLIGHT/FAN/Call bell point in existing conduit pipe and MS boxes includingcost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connectoretc. Group B (HSR 23.5.1.2)

1

-

-

... More
Wiring only in 1.5 sqmm PVC insulated copper conductor cable forLIGHT/FAN/Call bell point in existing conduit pipe and MS boxes includingcost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connectoretc. Group C (HSR 23.5.1.3)

1

-

-

... More
Wiring in existing conduit and MS box for 3-pin 5amp. Plug point by using 2no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire ,including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switchetc complete as required Group A (HSR 23.5.4.1)

1

-

-

... More
Wiring in existing conduit and MS box for 3-pin 5amp. Plug point by using 2no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire ,including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switchetc complete as required Group B (HSR 23.5.4.2)

1

-

-

... More
Wiring in existing conduit and MS box for 3-pin 5amp. Plug point by using 2no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire ,including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switchetc complete as required Group C (HSR 23.5.4.3)

1

-

-

... More
Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire forearthling, including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16Amp switch etc complete as required Group A (HSR 23.5.5.1)

1

-

-

... More
Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire forearthling, including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16Amp switch etc complete as required Group B (HSR 23.5.5.2)

1

-

-

... More
Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire forearthling, including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16Amp switch etc complete as required Group C (HSR 23.5.5.3)

1

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1)

1

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.5.6.2)

1

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.3.6.3)

1

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) (HSR 23.5.6.4)

1

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) (HSR 23.5.6.5)

1

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 2 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.6)

1

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 2 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.5.6.7)

1

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 2 run of Size 4 Sqmm(1/2.24mm) (HSR 23.5.6.8)

1

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 3 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.9)

1

-

-

... More
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 3 run of Size 2.50 Sqmm(1.1.80mm) (HSR 23.5.6.10)

1

-

-

... More
Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia (HSR 23.7.6.1)

1

-

-

... More
Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia (HSR 23.7.6.2)

1

-

-

... More
Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia (HSR 23.7.6.3)

1

-

-

... More
Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia (HSR 23.7.6.4)

1

-

-

... More
Supply and erection 5-30 A single phase A.C. energy metre, LCD display each 1920 and optical port, with rag bolts on wall/existing pedestal including the cost of rag bolts required to complete the job in all respect with necessary connections and bonding to earth. (HSR 23.8.5)

1

-

-

... More
Supply and erection 10-60 A Three phase A.C. energy metre , LCD display each 2206 and optical port, with rag bolts on wall/existing pedestal including the cost of rag bolts required to complete the job in all respect with necessary connections and bonding to earth. (HSR 23.8.8)

1

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects 1&2 Modules (HSR 23.8.10.1)

1

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects 3 Modules (HSR 23.8.10.2)

1

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects 4 Modules (HSR 23.8.10.3)

1

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects 6 Modules (HSR 23.8.10.4)

1

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects 8 Modules (HSR 23.8.10.5)

1

-

-

... More
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects 12 Modules (HSR 23.8.10.6)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch (HSR 23.8.11.1)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 2 way switch (HSR 23.8.11.2)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch (HSR 23.8.11.3)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket (HSR 23.8.11.4)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket (HSR 23.8.11.5)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. Bell Push (HSR 23.8.11.6)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. Step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type (HSR 23.8.11.8)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. TV Socket outlet modular type (HSR 23.8.11.9)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate (HSR 23.8.11.10)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable (HSR 23.8.11.11)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. USB Charger, 1000mA, 5V, 1 Module (HSR 23.8.11.12)

1

-

-

... More
Pdg. And fixing modular type accessorism of approved make in existing box including fixing and making necessary connections, complete in all respect. 32A D.P. Main Switch With Key Ring Tag 2 Module (HSR 23.8.11.13)

1

-

-

... More
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole onexisting wall/pedestal/Panel including bounding to earth and makingnecessary connections required to complete the job in all respect up to theentire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA (HSR 23.22.1.3)

1

-

-

... More
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole onexisting wall/pedestal/Panel including bounding to earth and makingnecessary connections required to complete the job in all respect up to theentire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA (HSR 23.22.1.4)

1

-

-

... More
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole onexisting wall/pedestal/Panel including bounding to earth and makingnecessary connections required to complete the job in all respect up to theentire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA (HSR 23.22.1.5)

1

-

-

... More
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole onexisting wall/pedestal/Panel including bounding to earth and makingnecessary connections required to complete the job in all respect up to theentire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 300 Amp, 25 KA (HSR 23.22.1.6)

1

-

-

... More
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole onexisting wall/pedestal/Panel including bounding to earth and makingnecessary connections required to complete the job in all respect up to theentire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 400 Amp, 50 KA (HSR 23.22.1.7)

1

-

-

... More
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole onexisting wall/pedestal/Panel including bounding to earth and makingnecessary connections required to complete the job in all respect up to theentire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 600 to 800 Amp, 50 KA (HSR 23.22.1.8)

1

-

-

... More
Supply and erection of double door sheet steel enclosure distribution boardsuitable for MCBS and ELCBS etc. recessed in wall including bonding toearth with all labour and material required to complete the job in all respectup to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) (HSR 23.22.4.2)

1

-

-

... More
Supply and erection of double door sheet steel enclosure distribution boardsuitable for MCBS and ELCBS etc. recessed in wall including bonding toearth with all labour and material required to complete the job in all respectup to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 12 way ( 2 incoming and 10 outgoing) (HSR 23.22.4.3)

1

-

-

... More
Supply and erection of double door sheet steel enclosure distribution boardsuitable for MCBS and ELCBS etc. recessed in wall including bonding toearth with all labour and material required to complete the job in all respectup to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and3phase*4 outgoing) (HSR 23.22.4.5)

1

-

-

... More
Supply and erection of double door sheet steel enclosure distribution boardsuitable for MCBS and ELCBS etc. recessed in wall including bonding toearth with all labour and material required to complete the job in all respectup to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing) (HSR 23.22.4.8)

1

-

-

... More
Supply and erection double pole/Four pole Residual (RCCB/ELCB) on240/415V, 5Hz. AC supply installed in existing sheet steel enclosuresincluding making necessary connections and bonding to earth with all labourand material required to complete the job in all respect up to the entiresatisfaction of the Engineer-in-Charge of the work DP RCCB 30ma sensitivity , 40 A (HSR 23.22.6.2)

1

-

-

... More
Supply and erection double pole/Four pole Residual (RCCB/ELCB) on240/415V, 5Hz. AC supply installed in existing sheet steel enclosuresincluding making necessary connections and bonding to earth with all labourand material required to complete the job in all respect up to the entiresatisfaction of the Engineer-in-Charge of the work DP RCCB 30ma sensitivity , 63 A (HSR 23.22.6.3)

1

-

-

... More
Supply and erection double pole/Four pole Residual (RCCB/ELCB) on240/415V, 5Hz. AC supply installed in existing sheet steel enclosuresincluding making necessary connections and bonding to earth with all labourand material required to complete the job in all respect up to the entiresatisfaction of the Engineer-in-Charge of the work FP RCCB 30ma sensitivity, 40 A (HSR 23.22.6.5)

1

-

-

... More
Supply and erection double pole/Four pole Residual (RCCB/ELCB) on240/415V, 5Hz. AC supply installed in existing sheet steel enclosuresincluding making necessary connections and bonding to earth with all labourand material required to complete the job in all respect up to the entiresatisfaction of the Engineer-in-Charge of the work FP RCCB 30ma sensitivity, 63 A (HSR 23.22.6.6)

1

-

-

... More
MISCELLANEOUS Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia (HSR 23.23.2.1)

1

-

-

... More
Providing and fixing fan hook made from 8 mm dia MS rod 75 cm long of required shape and size (HSR 23.23.4)

1

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. To 32 amp. SP (HSR 23.22.5.1)

1

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. SP (HSR 23.22.5.2)

1

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. To 32 amp. SPN (HSR 23.22.5.3)

1

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. SPN (HSR 23.22.5.4)

1

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. To 32 amp. TP (HSR 23.22.5.5)

1

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. TP (HSR 23.22.5.6)

1

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. To 32 amp. Four Pole (HSR 23.22.5.7)

1

-

-

... More
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Four Pole (HSR 23.22.5.8)

1

-

-

... More
Supply & erection of cable tray made out of 2 mm thick galavanised perforated sheet steel including erection of the same on wall or ceiling with necessary fixture and other material required to complete the Job in all respect upto the Entire statisfaction of Engineer-in-Charge of the work. 50 x 100 mm (HSR 23.23.6.1)

1

-

-

... More
Supply & erection of cable tray made out of 2 mm thick galavanised perforated sheet steel including erection of the same on wall or ceiling with necessary fixture and other material required to complete the Job in all respect upto the Entire statisfaction of Engineer-in-Charge of the work. 50 x 200 mm (HSR 23.23.6.2)

1

-

-

... More
Supply & erection of cable tray made out of 2 mm thick galavanised perforated sheet steel including erection of the same on wall or ceiling with necessary fixture and other material required to complete the Job in all respect upto the Entire statisfaction of Engineer-in-Charge of the work. 50 x 375 mm (HSR 23.23.6.3)

1

-

-

... More
Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and shealed in existing pipe/Channel and making necessary connection complete in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. 2 pair Telephone wire (HSR 23.23.8.1)

1

-

-

... More
Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and shealed in existing pipe/Channel and making necessary connection complete in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. 5 pair Telephone wire (HSR 23.23.8.2)

1

-

-

... More
S/E/T/C of Cat-6 cable in existing PVC conduit /PVC channel complete in all respect with all labour and material required to complete the job in all respect. (HSR 23.23.9)

1

-

-

... More
Dismantling old wiring points ( surface wiring system ) including necessary repairs to wall etc Light, fan or call bell Point including circuit/sub main wiring (HSR 23.25.1.1)

1

-

-

... More
Dismantling old wiring points ( surface wiring system ) including necessary repairs to wall etc Wall socket point including circuit/submain wiring (HSR 23.25.1.2)

1

-

-

... More
Dismantling old wiring points ( Recess wiring or partly recess partly surface system , recess Conduit and box not to be dismanUed ) including necessary repairs to wall etc Light, fan or call bell Point including circuit/sub main wiring (HSR 23.25.2.1)

1

-

-

... More
Dismantling old wiring points ( Recess wiring or partly recess partly surface system , recess Conduit and box not to be dismanUed ) including necessary repairs to wall etc Wall socket point including circuit/submain wiring (HSR 23.25.2.2)

1

-

-

... More
Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required . (HSR 24.1.1)

1

-

-

... More
Extra for using salt and charcoal / coke for pipe earth electrode as required. (HSR 24.1.2)

1

-

-

... More
Providing and laying earth connections from earth electrode with 4.00 mm G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11)

1

-

-

... More
Laying of underground cable 1 metre below ground level covered with sand and bricks including excavation and refilling of trenches 2.5 Sq mm to 10 Sq mm 2 to 4 Core (HSR 24.2.2.1)

1

-

-

... More
Laying of underground cable 1 metre below ground level covered with sand and bricks including excavation and refilling of trenches 16 Sq mm to 35 sqmm 2 to 4 Core (HSR 24.2.2.2)

1

-

-

... More
Laying of underground cable 1 metre below ground level covered with sand and bricks including excavation and refilling of trenches 50 Sq mm to 150 sqmm 2 to 4 Core (HSR 24.2.2.3)

1

-

-

... More
Laying of underground cable 1 metre below ground level covered with sand and bricks including excavation and refilling of trenches 185 sqmm to 240 sqmm 3 to 3½ Core (HSR 24.2.2.4)

1

-

-

... More
Laying of underground cable 1 metre below ground level covered with sand and bricks including excavation and refilling of trenches 300 sqmm to 400 sqmm 3 to 3½ Core (HSR 24.2.2.5)

1

-

-

... More
Laying of underground cable in pipe /existing open/closed trench etc as 2.5 Sq mm to 10 Sq mm 2 to 4 Core (HSR 24.2.4.1)

1

-

-

... More
Laying of underground cable in pipe /existing open/closed trench etc as 16 Sq mm to 35 sqmm 2 to 4 Core (HSR 24.2.4.2)

1

-

-

... More
Laying of underground cable in pipe /existing open/closed trench etc as 50 Sq mm to 150 sqmm 2 to 4 Core (HSR 24.2.4.3)

1

-

-

... More
Laying of underground cable in pipe /existing open/closed trench etc as 185 sqmm to 240 sqmm 3 to 3½ Core (HSR 24.2.4.4)

1

-

-

... More
Laying of underground cable in pipe /existing open/closed trench etc as 300 sqmm to 400 sqmm 3 to 3½ Core (HSR 24.2.4.5)

1

-

-

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required Suitable for 70 to 120 sqmm 3 core XLPE Cable (HSR 24.3.3.1)

1

-

-

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required For 70 sqmm to 95 sqmm Cable 3 to 4 Core (HSR 24.3.5.1)

1

-

-

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required For 120sqmm to 150 sqmm Cable 3 to 4 Core (HSR 24.3.5.2)

1

-

-

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required For 185 sqmm Cable 240 sqmm cable 3 to 4 Core (HSR 24.3.5.3)

1

-

-

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required For 300 sqmm to 400 sqmm Cable 3 to 4 core (HSR 24.3.5.4)

1

-

-

... More
Supply and erection of 32mm dia metre 1.5 m long bracket (B-class) each 573 making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing of GI. bracket on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections. (HSR 24.4.3)

1

-

-

... More
Supply and errection of Hot Dip Galavanized octagonal pole 3 thichness, with base plate including of nut and bolts and all accessories as supplied by the manufacture including cost of fundation accessories etc. The foundation bolts as per manufacturer design should be hot dipped galanized pole complet of 2 nos. 100 A, 4 pole nature links including connection etc with suitable connection arrangments for 2 no. MCB/ kit kat including cost of RCC 1:1:5:3 for foundation of size 0.7 m x 0.7m x 1.8 m with minimum 8 Nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm CC for fixing the pole with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work 7 M long pole with top dia 70 mm and bottom dia 130 mm with base plate of size 220 x 220 x 12mm. (HSR 24.4.8.5)

1

-

-

... More
Supply and errection of Hot Dip Galavanized octagonal pole 3 thichness, with base plate including of nut and bolts and all accessories as supplied by the manufacture including cost of fundation accessories etc. The foundation bolts as per manufacturer design should be hot dipped galanized pole complet of 2 nos. 100 A, 4 pole nature links including connection etc with suitable connection arrangments for 2 no. MCB/ kit kat including cost of RCC 1:1:5:3 for foundation of size 0.7 m x 0.7m x 1.8 m with minimum 8 Nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm CC for fixing the pole with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work 8M long pole with top dia 70 mm and bottom dia 135 mm with base plate of size 225 x 225 x 16mm. (HSR 24.4.8.6)

1

-

-

... More
Supply and errection of Hot Dip Galavanized octagonal pole 3 thichness, with base plate including of nut and bolts and all accessories as supplied by the manufacture including cost of fundation accessories etc. The foundation bolts as per manufacturer design should be hot dipped galanized pole complet of 2 nos. 100 A, 4 pole nature links including connection etc with suitable connection arrangments for 2 no. MCB/ kit kat including cost of RCC 1:1:5:3 for foundation of size 0.7 m x 0.7m x 1.8 m with minimum 8 Nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm CC for fixing the pole with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work 9 M long pole with top dia 70 mm and bottom dia 155 mm with base plate of size 260 x 260 x 16 mm. (HSR 24.4.8.7)

1

-

-

... More
Supply and erection of weather proof MS box size 20cm x 30cm x 10cm of 16G and covered with MS sheet hinged cover having locking arrangement housed in 1:2:4 CC muff of size 40cm dia 55cm high including cost of PVC pipe of suitable size for incoming and outgoing cable, 4 copper bars of size 20 mm x 3mm, 125 mm duly tined, insulated and supported with porcelain insulator, 2 nos. 16 A 416V kit kat fixed in the MS box including painting etc complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. (HSR 24.4.17)

1

-

-

... More
Supply and errection of double walled corrugated (DWC) HDPE pipe laid 1 meter below ground level including diging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of the labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work HDPE pipe 63/50 mm outer dia/ inner dia (HSR 24.5.2.3)

1

-

-

... More
Supply and errection of double walled corrugated (DWC) HDPE pipe laid 1 meter below ground level including diging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of the labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work HDPE pipe 90/75 mm outer dia/ inner dia (HSR 24.5.2.4)

2

-

-

... More
Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/Cubic meter of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1 :5: 1 O of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 7 Meter Octagonal Pole (HSR 24.8.5)

1

-

-

... More
Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/Cubic meter of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1 :5: 1 O of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 8 Meter Octagonal Pole (HSR 24.8.6)

1

-

-

... More
Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/Cubic meter of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1 :5: 1 O of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 9 Meter Octagonal Pole (HSR 24.8.7)

1

-

-

... More
Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 75 kg/Cubic meter of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for high mast octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 12.5 Meter High Mast (HSR 24.9.1)

1

-

-

... More
Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 75 kg/Cubic meter of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for high mast octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 16.0 Meter High Mast (HSR 24.9.2)

1

-

-

... More
Digging & Refilling of trench 30 cm below ground level for erection of pipe (up to deapth of 1 Meter.) underground cable excluding the cost of cable /pipe complete in all respect. (HSR 24.10.1)

1

-

-

... More
S/E of AC ceiling fan capacitor type complete with shackle 300mm down rod etc. Make USHA , Bajaj , Crompton (NS) 1200 mm sweep

1

-

-

... More
S/E of AC ceiling fan capacitor type complete with shackle 300mm down rod etc. Make USHA , Bajaj , Crompton (NS) 1400 mm sweep

1

-

-

... More
S/E of XLPE (E) 11 KV HT aluminum conductor armoured cable ISI mark laid in 1 meter below ground level with sand & bricks with all labour and material including digging and refilling of trench, required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (NS) (i) 35 sqmm 3 core XLPE cable

1

-

-

... More
S/E of XLPE (E) 11 KV HT aluminum conductor armoured cable ISI mark laid in 1 meter below ground level with sand & bricks with all labour and material including digging and refilling of trench, required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (NS) (ii) 50 sqmm 3 core XLPE cable

1

-

-

... More
S/E of XLPE (E) 11 KV HT aluminum conductor armoured cable ISI mark laid in 1 meter below ground level with sand & bricks with all labour and material including digging and refilling of trench, required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (NS) (iii)120 sqmm 3 core XLPE cable

1

-

-

... More
S/E of XLPE (E) 11 KV HT aluminum conductor armoured cable ISI mark laid in existing pipe /trenches/surface with all labour and material including required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (NS) (i) 35 sqmm 3 core XLPE cable

1

-

-

... More
S/E of XLPE (E) 11 KV HT aluminum conductor armoured cable ISI mark laid in existing pipe /trenches/surface with all labour and material including required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (NS) (ii) 50 sqmm 3 core XLPE cable

1

-

-

... More
S/E of XLPE (E) 11 KV HT aluminum conductor armoured cable ISI mark laid in existing pipe /trenches/surface with all labour and material including required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (NS) (iii) 120 sqmm 3 core XLPE cable

1

-

-

... More
Supply and erection of under ground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches. (NS) (i) 16 Sq. mm 2 Core Cable . Al. Ar.

1

-

-

... More
Supply and erection of under ground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches. (NS) (ii) 16 Sq. mm 4 Core Cable . Al. Ar.

1

-

-

... More
Supply and erection of under ground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches. (NS) (iii) 25 Sq. mm 4 Core Cable .Al. Ar.

1

-

-

... More
Supply and erection of under ground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches. (NS) (iv) 50 Sq. mm 4 Core Cable .Al. Ar.

1

-

-

... More
Supply and erection of under ground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches. (NS) (v) 95 Sq. mm 3.5 Core Cable.Al. Ar.

1

-

-

... More
Supply and erection of under ground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches. (NS) (vi) 120 Sq. mm 3.5 Core Cable.Al. Ar.

1

-

-

... More
Supply and erection of under ground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches. (NS) (vii) 185 Sq. mm 3.5 Core Cable.Al. Ar.

1

-

-

... More
Supply and erection of under ground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches. (NS) (viii) 240 Sq. mm 3.5 Core Cable.Al. Ar.

1

-

-

... More
Supply and erection of under ground cable loose in existing pipe/trench including necessary connections. (NS) (i) 16 Sq. mm 2 Core Cable . Al. Ar.

1

-

-

... More
Supply and erection of under ground cable loose in existing pipe/trench including necessary connections. (NS) (ii) 16 Sq. mm 4 Core Cable . Al. Ar.

1

-

-

... More
Supply and erection of under ground cable loose in existing pipe/trench including necessary connections. (NS) (iii) 25 Sq. mm 4 Core Cable .Al. Ar.

1

-

-

... More
Supply and erection of under ground cable loose in existing pipe/trench including necessary connections. (NS) (iv) 50 Sq. mm 4 Core Cable .Al. Ar.

1

-

-

... More
Supply and erection of under ground cable loose in existing pipe/trench including necessary connections. (NS) (v) 95 Sq. mm 3.5 Core Cable.Al. Ar.

1

-

-

... More
Supply and erection of under ground cable loose in existing pipe/trench including necessary connections. (NS) (vi) 120 Sq. mm 3.5 Core Cable.Al. Ar.

1

-

-

... More
Supply and erection of under ground cable loose in existing pipe/trench including necessary connections. (NS) (vii) 185 Sq. mm 3.5 Core Cable.Al. Ar.

1

-

-

... More
Supply and erection of under ground cable loose in existing pipe/trench including necessary connections. (NS) (viii) 240 Sq. mm 3.5 Core Cable.Al. Ar.

1

-

-

... More
10 pair Telephone wire jelly filled armoured cable 0.51mm copper complete in all respect. (NS)

1

-

-

... More
20 pair Telephone wire jelly filled armoured cable 0.51mm copper complete in all respect. (NS)

1

-

-

... More
50 pair Telephone wire jelly filled armoured cable 0.51mm copper complete in all respect. (NS)

1

-

-

... More
S/E/T/C of RG-1 1 COAXIAL cable in existing PVC pipe /channel complete in all respect with all labour and material required to complete the job in all respect. (NS)

1

-

-

... More
Supply and erection of heavy duty 4 pole ON load changeover load breaker switch comprising of switches 63 amp to 400 amp suitable for operation on 415 V 50 Hz AC supply complete with handle assembly having door interlock & padlocking arrangement on existing panel / including making necessary connections with petty material required to complete the job. (NS) (i) 100Amp 4P Changeover Switch

1

-

-

... More
Supply and erection of heavy duty 4 pole ON load changeover load breaker switch comprising of switches 63 amp to 400 amp suitable for operation on 415 V 50 Hz AC supply complete with handle assembly having door interlock & padlocking arrangement on existing panel / including making necessary connections with petty material required to complete the job. (NS) (ii) 200Amp 4P Changeover Switch

1

-

-

... More
Supply and erection of heavy duty 4 pole ON load changeover load breaker switch comprising of switches 63 amp to 400 amp suitable for operation on 415 V 50 Hz AC supply complete with handle assembly having door interlock & padlocking arrangement on existing panel / including making necessary connections with petty material required to complete the job. (NS) (iii) 400Amp 4P Changeover Switch

1

-

-

... More
Supply and erection of heavy duty 4 pole ON load changeover load breaker switch comprising of switches 63 amp to 400 amp suitable for operation on 415 V 50 Hz AC supply complete with handle assembly having door interlock & padlocking arrangement on existing panel / including making necessary connections with petty material required to complete the job. (NS) (iv) 630Amp 4P Changeover Switch

1

-

-

... More
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. (NS)

1

-

-

... More
Dismantling of pole/ street light standard/ strut embedded in brick ballast foundation etc. as required (NS)

1

-

-

... More
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required (NS)

1

-

-

... More
Rewinding of Ceiling Fan complete with copper wire winding and all petty material required to complete the job after deducting old scrap winding complte in all respect (NS) (i) 1200mm

1

-

-

... More
Rewinding of Ceiling Fan complete with copper wire winding and all petty material required to complete the job after deducting old scrap winding complte in all respect (NS) (ii) 1400mm

1

-

-

... More
Rewinding of Ceiling Fan complete with copper wire winding , bearing , small parts and all petty material required to complete the job after deducting old scrap winding complte in all respect. (i) 1200mm (NS)

1

-

-

... More
Rewinding of Ceiling Fan complete with copper wire winding , bearing , small parts and all petty material required to complete the job after deducting old scrap winding complte in all respect.(NS) (ii) 1400mm

1

-

-

... More
Rewinding of Exhaust Fan 300mm to 450mm complete with copper wire winding , bearing , small parts and all petty material required to complete the job after deducting old scrap winding complte in all respect (NS)

1

-

-

... More
S/E of reccessed type≤42 watt fullwindow glare free opal diffuse LED Panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated whire housing. Total system lumen of 42 watt LED should be 5100 or above in cool dry light (5700K), Power factor≥0.95, CRI (Ra)≥80, LED LAmp efficiency≥140lm/w, Average life50000 hours, complete with all accessories as required with connections including 3 year defect liability period and free replacement in case of non functioning of the light fixture. Make: Bajaj, Havells, Philips (NS)

1

-

-

... More
S/E of T-8 LED tube rod 20 wattTotal system of 20 watt LED should be 2000 or above in coll day light (5700 K to 6500 K) power factor 0.95, CRI80, Average life50000 Hours Make: Bajaj, Havells, Philips (NS)

1

-

-

... More
S/E of surface/ wall mounted ≤ 40watt integrated LED 4 feet fitting with epoxy powder coatted white/gray extruded Aluminum channel housing for efficient heat dissipation Total system of 40 watt LED should be 3960 or above in coll day light (5700 K to 6500 K) power factor 0.95, CRI80, Average life50000 Hours complete with mounting bracket and accessories.Havells/Philiphs/Wipro/ Bajaj Make ( Industrial ) (NS)

1

-

-

... More
S/E of surface/ wall mounted ≤ 20watt integrated LED 4 feet fitting with epoxy powder coatted white/gray extruded Aluminum channel housing for efficient heat dissipation Total system of 20 watt LED should be 2000 or above in coll day light (5700 K to 6500 K) power factor 0.95, CRI80, Average life50000 Hours complete with mounting bracket and accessories.Havells/Bajaj//Philiphs/Wipro Make ( Industrial ) (NS)

1

-

-

... More
S/E of surface/ wall mounted 1'*4' 36 watt ≤ 36watt integrated LED 4 feet fitting with epoxy powder coatted white/gray extruded Aluminum channel housing for efficient heat dissipation Total system of 36 watt LED should be 4000 or above in coll day light (5700 K to 6500 K) power factor 0.95, CRI80, Average life50000 Hours complete with mounting bracket and accessories.Havells/Bajaj//Philiphs/Wipro Make ( Industrial ) (NS)

1

-

-

... More
S/E of Propeller type AC ventalating fans ( exhaust fan ) with necessary earthing of fan complete with louver shutter , 380mm sweep 900RPM ( Heavy Duty ) Make Orient , Usha , Khaitan , Crompton (NS)

1

-

-

... More
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Cable Size 1 sqmm (14/0.03) (NS)

1

-

-

... More
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. (NS) 1.5 sqmm copper wire

1

-

-

... More
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. (NS) 2.5 sqmm copper wire

1

-

-

... More
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. (NS) 4.0 sqmm copper wire

1

-

-

... More
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. (NS) 6.0 sqmm copper wire

1

-

-

... More
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. (NS) 10.00 sqmm copper wire

1

-

-

... More
S/E of flat PVC service wire 10 sqmm 2 core aluminum complete in all respect upto the entire satisfaction of the Engineer-in-charge of work. (NS)

1

-

-

... More
S/I/T/C of push On/OFF type 25Amp modulator type motor starter switch for AC (NS)

1

-

-

... More
Dismentalling of 9/11 Meter PCC Pole complete in all respect and return to store as per satisfaction of EIC. (NS)

1

-

-

... More
Erection of 9/11 Meter PCC Pole complete in all respect and pick from store as per satisfaction of EIC. (NS)

1

-

-

... More
Dismentalling of ACSR / AB Cable from 9/11 Meter PCC Pole complete in all respect and return to store as per satisfaction of EIC.(NS)

1

-

-

... More
Erection of ACSR/AB Cable from 9/11 Meter PCC Pole complete in all respect and pick from store as per satisfaction of EIC.(NS)

1

-

-

... More
Dismentalling of existing Window Air Conditioner 1.0 ton to 2.0 ton with stablizer , copper piping etc in all respect and return to store as per satisfaction of EIC. (NS)

1

-

-

... More
Erection of Window Air Conditioner 1.0 ton to 2.0 tonwith stablizer , copper piping etc in all respect and pick from store as per satisfaction of EIC. (NS)

1

-

-

... More
Dismentalling of existing Split Air Conditioner 1.0 ton to 2.0 ton with stablizer , copper piping etc in all respect and return to store as per satisfaction of EIC. (NS)

1

-

-

... More
Erection of Split Air Conditioner 1.0 ton to 2.0 ton with stablizer , copper piping etc in all respect and pick from store as per satisfaction of EIC. (NS)

1

-

-

... More
Replacement of Old Compressor with new compressor 1.0 ton to 2.0 ton after decucting cost of old compressor etc in all respect and return to store as per satisfaction of EIC. Re- filling of R410A/R32 Air conditioner Gas in Split/Window 1.0 ton to 2.0 ton AC complete in all respect. (NS)

1

-

-

... More
S/E of trenchless boring of road by HDD machine for laying required size of HDPE pipe 6" with socket reducer as per dia of cable at the end of pipe to closed the end of pipe to avoid entering of sand in pipe and all petty material required to complete the job as per entire satisfaction of the EIC. (NS)

1

-

-

... More
Labour Charges of Dehydration of Transformer Oil complete with Labour for empty , refilling and other overhead charges but excluding of oil upto satisfaction of EIC. (NS) (i) upto 100/125KVA

1

-

-

... More
Labour Charges of Dehydration of Transformer Oil complete with Labour for empty , refilling and other overhead charges but excluding of oil upto satisfaction of EIC. (NS) (ii) Upto 200/250KVA

1

-

-

... More
Labour Charges of Dehydration of Transformer Oil complete with Labour for empty , refilling and other overhead charges but excluding of oil upto satisfaction of EIC. (NS) (iii) Upto 400/500/630KVA

1

-

-

... More
Supply of fresh transformer oil for existing transformers in university/outside KVK's station complete with filling, transportation etc. (NS)

1

-

-

... More
Shifting of Existing Transformer upto 630KVA including cost of hydra , vehicle ,dismentalling of connection and reconnection of at new place complete in all respect upto entire satisfaction of EIC. Upto 100/125KVA (NS)

1

-

-

... More
Shifting of Existing Transformer upto 630KVA including cost of hydra , vehicle ,dismentalling of connection and reconnection of at new place complete in all respect upto entire satisfaction of EIC. Upto 200/250KVA (NS)

1

-

-

... More
Shifting of Existing Transformer upto 630KVA including cost of hydra , vehicle ,dismentalling of connection and reconnection of at new place complete in all respect upto entire satisfaction of EIC. Upto 400/500/630KVA (NS)

1

-

-

... More
Making of Suitable size foundations as per design of transformer upto 630KVA including cost of material required for making suitable caoacity foundation as per the design of manufacturers complete in all respect upto entire satisfaction of EIC.Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/Cubic meter of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per OEM recommendations to provide levelled surface for placement of the DG set complete in all respects and as per directions of Engineer-in-charge (Size of foundation assumed = 5.0x1 .Bx1 .Om) (NS) Upto 100/125KVA

1

-

-

... More
Making of Suitable size foundations as per design of transformer upto 630KVA including cost of material required for making suitable caoacity foundation as per the design of manufacturers complete in all respect upto entire satisfaction of EIC.Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/Cubic meter of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per OEM recommendations to provide levelled surface for placement of the DG set complete in all respects and as per directions of Engineer-in-charge (Size of foundation assumed = 5.0x1 .Bx1 .Om) (NS) Upto 200/250KVA

1

-

-

... More
Making of Suitable size foundations as per design of transformer upto 630KVA including cost of material required for making suitable caoacity foundation as per the design of manufacturers complete in all respect upto entire satisfaction of EIC.Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/Cubic meter of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per OEM recommendations to provide levelled surface for placement of the DG set complete in all respects and as per directions of Engineer-in-charge (Size of foundation assumed = 5.0x1 .Bx1 .Om) (NS) Upto 400/500/630KVA

1

-

-

... More
Hiring Charges of 62.5 KVA DG set complete with to and fro from supplier end to university campus including freight but excluding cost of oil . (NS)

1

-

-

... More
Hiring Charges of 125 KVA DG set complete with to and fro from supplier end to university campus including freight but excluding cost of oil . (NS)

1

-

-

... More
Hiring Charges of 250 KVA DG set complete with to and fro from supplier end to university campus including freight but excluding cost of oil . (NS)

1

-

-

... More
Repair / Service of 11KV VCB complete with accessories details are :- (NS) (i) TNC Switch

1

-

-

... More
Repair / Service of 11KV VCB complete with accessories details are :- (NS) (ii) Digital Ammeter

1

-

-

... More
Repair / Service of 11KV VCB complete with accessories details are :- (NS) (iii) Servicing Charges

1

-

-

... More
Repair / Service of 11KV VCB complete with accessories details are :- (NS) (iv) Shunt

1

-

-

... More
Repair / Service of 11KV VCB complete with accessories details are :- (NS) (v) Motor,gear box , girrari , Mechanism

1

-

-

... More
Repair / Service of 11KV VCB complete with accessories details are :- (NS) (vi) 11KV SF6 Breaker Service complete

1

-

-

... More
Supply , installation , testing and commissioning of 24 port POE Access switch with the 3 year free comprehensive warranty period and 24*7 direct OEM TAC spot including cost of petty material required to complete the work upto the entire satisfaction of EIC having following techanical specification switch shoul offer wire speed and non blocking switching with 24 / 10 /100 /1000 RJ 45 POE / POE +ethernet ports and additional for SFP + ( IG/10G) fibre based ports , minimum 2 port populated with 10G MMF Access switches should spot non blocking switching fabric capacity of minimum 88 GB PS and minimum line rate forwarding capacity of 57 MPPS access switch shoul spot minimum 16KMAC addresses and minimum 4K active VLANs Acess switch shoul have stacking capability with minimum stacking band with widthof 40GBPS and should spot minimum of 8 unit stack from day 1 . (NS)

1

-

-

... More
S/E of lED street light of system voltage ≤70 watt IP 66 multiple LED with lens optics and pressure die-cast aluminium housing for effective thermal management. Total system lumen of ≤70 watt LED should be 8400 or above in cool day light.(5700K), Lumen efficieny 120 lm/W, power factor≥0.95, CRI≥ 70, avg. life≥5000 hours, complete with all accessories as required with connections including 3 years defect liability period and free rreplacement in case of non-functioning of the light fixture Make Havells, Bajaj , Philiphs (NS)

1

-

-

... More
S/E of lED street light of system voltage ≤90 watt IP 66 multiple LED with lens optics and pressure die-cast aluminium housing for effective thermal management. Total system lumen of ≤90 watt LED should be 10800 or above in cool day light.(5700K), Lumen efficieny 120 lm/W, power factor≥0.95, CRI≥ 70, avg. life≥5000 hours, complete with all accessories as required with connections including 3 years defect liability period and free rreplacement in case of non-functioning of the light fixture Make Havells, Bajaj , Philiphs (NS)

1

-

-

... More
S/E of double arm street light bracket of size 1.5 Meter long made of 32/50 mm dia GI pipe B-class ISI, with collerr pipe (GI) 75mm dia 300mm long duly welded, painted with 2 coats of aluminium paint on bracket for fixing on the existing 7 Meter. Hot Dip galvanized octagonal pole complete the job in all respects. (NS)

1

-

-

... More
S/E of single arm street light bracket of size 1.5 Meter long made of 32/50 mm dia GI pipe B-class ISI, with collerr pipe (GI) 75mm dia 300mm long duly welded, painted with 2 coats of aluminium paint on bracket for fixing on the existing 7 Meter. Hot Dip galvanized octagonal pole complete the job in all respects.(NS)

1

-

-

... More
Supply Installation testing & commissioning of 6-core Multimode OM3 OFC including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (MAKE : Molex/Siemon/Dlink) (NS)

1

-

-

... More
Supply Installation testing & commissioning of 12-core Multimode OM3 OFC including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (MAKE : Molex/Siemon/Dlink) (NS)

1

-

-

... More
Supply Installation testing & commissioning of Om3 Fibre Patch cord duplex including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (MAKE : Molex/Siemon/Dlink) (NS)

1

-

-

... More
Supply & Erection of Termination Kit of OM3 OFC 6/12 Pair Cables complete with Labour for Filling in all respect. (NS)

1

-

-

... More
Supply & Erection of Jointing Kit of OM3 OFC 6/12 Pair Cables Cables complete with Labour for Filling in all respect. (NS)

1

-

-

... More
Labour Charges of Splishing Jointing Kit of OM3 OFC Cables complete with Labour for Filling in all respect. (NS)

1

-

-

... More
Labour Charges of road crossing of 3"/4" dia pipe for LT/HT cables upto depth of 1 mtr below ground level complete in all respect but excluding cost of PVC pipe etc. (NS)

1

-

-

... More
Supply installation testing and commissioning of wall/ free floor mounting dust and vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet required hardware 3 mm thick bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted 2 coat of Zinc/ Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/ switch war. (NS)

1

-

-

... More
Supplying and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation complete in all respects. (NS)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.