Bridge And Roof Company India Limited Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Bridge And Roof Company India Limited Tender

Works
Civil And Construction
Consultancy Services
Civil And Architectural Services
Eprocure
Opening Date29 Jun 2024
Closing Date16 Sep 2024
Tender Amount₹ 22,50,45,503 
Notes
Download

Costs

Summary

For Carrying Out Various Civil, Structural, Piping, Equipment And Ndt Works As Per Standard Specification In Connection With Composite Work For

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
NB 16.000 INCHES

1

18264

18264

... More
NB 18.000 INCHES

1

20547

20547

... More
NB 20.000 INCHES

1

22829

22829

... More
NB 24.000 INCHES

1

27395

27395

... More
NB 26.000 INCHES

1

29678

29678

... More
NB 30.000 INCHES

1

34244

34244

... More
NB 36.000 INCHES

1

41093

41093

... More
NB 40.000 INCHES

1

45659

45659

... More
C.S MITRE BENDS-90; THK. 10MM AND = 20MM

-

-

-

... More
NB 52.000 INCHES

1

71233

71233

... More
NB 60.000 INCHES

1

82192

82192

... More
C.S MITRE BENDS-45; THK. = 10MM

-

-

-

... More
NB 16.000 INCHES

1

12176

12176

... More
NB 18.000 INCHES

1

13698

13698

... More
NB 26.000 INCHES

1

19786

19786

... More
NB 30.000 INCHES

1

22829

22829

... More
NB 36.000 INCHES

1

27395

27395

... More
C.S ECC. REDUCERS; THK. = 10MM

-

-

-

... More
NB 18.000 INCHES

1

19786

19786

... More
NB 20.000 INCHES

1

21688

21688

... More
NB 36.000 INCHES

1

39191

39191

... More
C.S ECC. REDUCERS; THK. 10MM AND = 20MM

-

-

-

... More
NB 44.000 INCHES

1

57534

57534

... More
NB 52.000 INCHES

1

68036

68036

... More
NB 60.000 INCHES

1

78539

78539

... More
PIPING (ABOVE GROUND) Transportation of all piping items from Owner's storage point to work site / work shop; fabrication including cutting, edge preparation (inclusive of grinding the edges of pipe, pipe spools, fittings, flanges etc. to match with the mating edges of uneven/ different thickness wherever required); fitup, bending, preheating wherever required, welding, threading and laying of pipes and pipe spools (spools along with supports) of all types and thickness over sleepers, overhead on racks and at all elevations, hook-ups with existing piping, connecting with equipment nozzles, strainers, steam traps, orifice assemblies, spray nozzles, rotameters, tappings for pressure gauges, thermowells, sample connections, sample coolers, closed sample system cabinets etc. and fixing of gaskets, bolts, nuts including application of torque wherever required & all other inline instruments and fittings, like elbows, reducers, tees, flanges, spectacle blinds and spacer&blinds, piping specials such as mitres and fabricated fittings, vents, drains (but excluding reinforcing pads), SW valves upto 1.5 NB, Steam Supply/ Condensate Recovery stations(Cast/Fabricated), Supply & welding of Strip as per EIL Std 7-51-0112 to all pipes before hydro-testing at exit points of Units for earthing purpose; alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified draining, drying by compressed air, performing Positive Material Identification(PMI) using alloy analysers, completing all such works in all respects (including preparation of isometrics as mentioned in the Scope of Work for the job) as per the specifications, drawings and instructions of Engineer-in-Charge. PMI shall be performed by third party as defined in PMI spec.Rates for tubing (if any) shall include rates for valves, fittings, all in line instruments and testing etc. Carbon steel piping includes LTCS piping also.

-

-

-

... More
CARBON STEEL PIPING (NON IBR); THK. = 10MM

-

-

-

... More
FABRICATION (BUTT WELD)

-

-

-

... More
NB UPTO 1.5 INCH

4

1548

387

... More
NB 2 INCH - 6 INCH

9000

3483000

387

... More
NB 8 INCH - 14 INCH

20000

7740000

387

... More
NB 16 INCH - 24 INCH

19000

7353000

387

... More
NB 26 INCH - 36 INCH

12000

4644000

387

... More
NB 38 INCH - 48 INCH

1500

580500

387

... More
NB 50 INCH - 60 INCH

30

11610

387

... More
FABRICATION (FILLET WELD)

-

-

-

... More
NB UPTO 1.5 INCH

900

311400

346

... More
NB 2 INCH - 6 INCH

50

17300

346

... More
NB 8 INCH - 14 INCH

20

6920

346

... More
NB 16 INCH - 24 INCH

200

69200

346

... More
NB 26 INCH - 36 INCH

200

69200

346

... More
NB 50 INCH - 60 INCH

30

10380

346

... More
ERECTION (OTHER THAN SPOOL)

-

-

-

... More
NB UPTO 1.5 INCH

2500

320000

128

... More
NB 2 INCH - 6 INCH

58000

7424000

128

... More
NB 8 INCH - 14 INCH

160000

20480000

128

... More
NB 16 INCH - 24 INCH

130000

16640000

128

... More
NB 26 INCH - 36 INCH

140000

17920000

128

... More
NB 38 INCH - 48 INCH

7000

896000

128

... More
NB 50 INCH - 60 INCH

30

3840

128

... More
CARBON STEEL PIPING (NON IBR); THK. 10MM AND = 20MM

-

-

-

... More
FABRICATION (BUTT WELD)

-

-

-

... More
NB 2 INCH - 6 INCH

300

139800

466

... More
NB 8 INCH - 14 INCH

2700

1258200

466

... More
NB 16 INCH - 24 INCH

2700

1258200

466

... More
NB 26 INCH - 36 INCH

2200

1025200

466

... More
NB 38 INCH - 48 INCH

300

139800

466

... More
NB 50 INCH - 60 INCH

4000

1864000

466

... More
ABOVE 60 INCH

10000

4660000

466

... More
ERECTION (OTHER THAN SPOOL)

-

-

-

... More
NB 2 INCH - 6 INCH

1200

168000

140

... More
NB 8 INCH - 14 INCH

18000

2520000

140

... More
NB 16 INCH - 24 INCH

12000

1680000

140

... More
NB 26 INCH - 36 INCH

13000

1820000

140

... More
NB 38 INCH - 48 INCH

200

28000

140

... More
NB 50 INCH - 60 INCH

35500

4970000

140

... More
ABOVE 60 INCH

75000

10500000

140

... More
CARBON STEEL PIPING (IBR); THK. = TO 10MM

-

-

-

... More
FABRICATION (BUTT WELD)

-

-

-

... More
NB UPTO 1.5 INCH

100

40500

405

... More
NB 2 INCH - 6 INCH

950

384750

405

... More
NB 8 INCH - 14 INCH

2100

850500

405

... More
NB 16 INCH - 24 INCH

2000

810000

405

... More
NB 26 INCH - 36 INCH

2500

1012500

405

... More
FABRICATION (FILLET WELD)

-

-

-

... More
NB UPTO 1.5 INCH

5000

1820000

364

... More
ERECTION (OTHER THAN SPOOL)

-

-

-

... More
NB UPTO 1.5 INCH

3700

525400

142

... More
NB 2 INCH - 6 INCH

4000

568000

142

... More
NB 8 INCH - 14 INCH

8700

1235400

142

... More
NB 16 INCH - 24 INCH

9500

1349000

142

... More
NB 26 INCH - 36 INCH

11500

1633000

142

... More
CARBON STEEL PIPING (IBR); THK. 10MM AND = 20MM

-

-

-

... More
FABRICATION (BUTT WELD)

-

-

-

... More
NB 2 INCH - 6 INCH

8

3904

488

... More
NB 8 INCH - 14 INCH

980

478240

488

... More
NB 16 INCH - 24 INCH

1400

683200

488

... More
NB 26 INCH - 36 INCH

1800

878400

488

... More
ERECTION (OTHER THAN SPOOL)

-

-

-

... More
NB 8 INCH - 14 INCH

4300

679400

158

... More
NB 16 INCH - 24 INCH

7700

1216600

158

... More
NB 26 INCH - 36 INCH

11400

1801200

158

... More
CARBON STEEL PIPING (IBR); THK. 20MM AND = 40MM

-

-

-

... More
FABRICATION (BUTT WELD)

-

-

-

... More
NB 16 INCH - 24 INCH

550

466950

849

... More
NB 26 INCH - 36 INCH

2330

1978170

849

... More
ERECTION (OTHER THAN SPOOL)

-

-

-

... More
NB 16 INCH - 24 INCH

3000

684000

228

... More
NB 26 INCH - 36 INCH

12250

2793000

228

... More
STAINLESS STEEL PIPING (NON-IBR); THK. = 10MM

-

-

-

... More
FABRICATION (BUTT WELD)

-

-

-

... More
NB UPTO 1.5 INCH

30

23910

797

... More
NB 2 INCH - 6 INCH

1200

956400

797

... More
NB 8 INCH - 14 INCH

1800

1434600

797

... More
NB 16 INCH - 24 INCH

1550

1235350

797

... More
FABRICATION (FILLET WELD)

-

-

-

... More
NB UPTO 1.5 INCH

30

23070

769

... More
ERECTION (OTHER THAN SPOOL)

-

-

-

... More
NB UPTO 1.5 INCH

10

1610

161

... More
NB 2 INCH - 6 INCH

6000

966000

161

... More
NB 8 INCH - 14 INCH

10500

1690500

161

... More
NB 16 INCH - 24 INCH

9000

1449000

161

... More
ALLOY STEEL PIPING (NON-IBR); THK. = 10MM

-

-

-

... More
FABRICATION (BUTT WELD)

-

-

-

... More
NB 2 INCH - 6 INCH

370

225330

609

... More
FABRICATION (FILLET WELD)

-

-

-

... More
NB UPTO 1.5 INCH

30

16890

563

... More
ERECTION (OTHER THAN SPOOL)

-

-

-

... More
NB UPTO 1.5 INCH

3

453

151

... More
NB 2 INCH - 6 INCH

2500

377500

151

... More
STEAM TRACERS CARBON STEEL

-

-

-

... More
NB 0.500 INCHES

14600

4876400

334

... More
NB 0.750 INCHES

7

3507

501

... More
VALVES Transportation of all types of valves (Including special valves, motor operated valves, PRDS, PSVs, TSVs, Control valves, On-Off / Shutdown valves, Self actuating valves) from Owner's storage points to contractor's stores/worksite and installation of valves for all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification (PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge.

-

-

-

... More
FLANGED/WAFER VALVES INCLUDING MOV (UPTO 600#)

-

-

-

... More
NB 2.000 INCHES

33

20295

615

... More
NB 3.000 INCHES

15

13845

923

... More
NB 4.000 INCHES

4

4916

1229

... More
NB 6.000 INCHES

15

23055

1537

... More
NB 8.000 INCHES

11

25355

2305

... More
NB 10.000 INCHES

1

2767

2767

... More
NB 12.000 INCHES

1

3688

3688

... More
NB 16.000 INCHES

1

6147

6147

... More
NB 26.000 INCHES

1

8511

8511

... More
NB 30.000 INCHES

1

10059

10059

... More
NB 42.000 INCHES

1

14754

14754

... More
CONTROL VALVES (UPTO 600#)

-

-

-

... More
NB 3.000 INCHES

3

2769

923

... More
NB 4.000 INCHES

1

1383

1383

... More
NB 10.000 INCHES

1

3458

3458

... More
PRESS. RELIEF/ SAFETY VALVES, PILOT OP. SAFETY VALVES (UPTO 600#)( Size are valve inlet size)

-

-

-

... More
NB 0.750 INCHES

1

318

318

... More
NB 1.000 INCHES

6

2544

424

... More
NB 1.500 INCHES

1

530

530

... More
NB 8.000 INCHES

1

2651

2651

... More
SPRING SUPPORT ASSEMBLIES Transportation of all types of spring support assemblies from Owner's storage points to Agency's stores / worksite and installation of spring support assemblies for all rating including assembly, if any, fixing of gaskets bolts/nuts, welding attachments, wherever required and performing Positive Material Identification (PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Contractor to ensure that travel stops are removed and spring is locked in cold load position for Hydrotest. It shall be ensured that locking devices are removed and springs are properly set at hot load position during commissioning.

0.1

3037

30375

... More
BOLT TENSIONING Carrying out tensioning of bolted joints on all types of piping as called for in EIL Specification No.6-76-0002 on already erected system including supply of all materials, recording devices, instruments etc., Providing all normal and special equipment and gadgets, skilled / un skilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of Engineer-in-Charge. Some joints may require bolt tensioning more than once, but, payment for one joint shall be made only once.

-

-

-

... More
150# JOINTS

-

-

-

... More
NB 14.000 INCHES

13

29601

2277

... More
NB 16.000 INCHES

18

47754

2653

... More
NB 20.000 INCHES

100

327600

3276

... More
NB 24.000 INCHES

4

14088

3522

... More
NB 42.000 INCHES

2

11662

5831

... More
NB 46.000 INCHES

1

7109

7109

... More
300# JOINTS

-

-

-

... More
NB 10.000 INCHES

8

21880

2735

... More
NB 12.000 INCHES

10

29320

2932

... More
600# JOINTS

-

-

-

... More
NB 10.000 INCHES

3

9630

3210

... More
NB 12.000 INCHES

8

29488

3686

... More
REINFORCING PADS FOR PIPES Fabrication of reinforcing pads for pipe connection, wherever required, (from pipes only supplied by the Owner) and erection, fitup, welding & testing (including DP/MP), if required, of the same and performing Positive Material Identification(PMI) using alloy analysers as per the specifications, drawings and instructions of the Engineer-in- Charge. Note : Sizes mentioned for Reinforcing Pads are for branch pipe

-

-

-

... More
C.S REINFORCING PADS

-

-

-

... More
NB 2.000 INCHS

27

50031

1853

... More
NB 3.000 INCHS

15

41505

2767

... More
NB 4.000 INCHS

38

139840

3680

... More
NB 6.000 INCHS

27

148689

5507

... More
NB 8.000 INCHS

13

95342

7334

... More
NB 10.000 INCHS

6

54966

9161

... More
NB 12.000 INCHS

14

153832

10988

... More
NB 16.000 INCHS

4

58568

14642

... More
NB 20.000 INCHS

4

73184

18296

... More
NB 24.000 INCHS

1

21949

21949

... More
NB 44.000 INCHS

1

40218

40218

... More
RADIOGRAPHY Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specifications and instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Agency's fault and for additional radiography necessitated due to poor performance of Agency's welders shall be done at Agencyr's cost). Note : Unit for radiography quantity is "Nos of circumferencial weld joints"

-

-

-

... More
FOR JOINTS THK. = 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION)

-

-

-

... More
NB 0.750 INCHES

13

4095

315

... More
NB 2.000 INCHES

50

15750

315

... More
NB 3.000 INCHES

36

13464

374

... More
NB 4.000 INCHES

140

56700

405

... More
NB 6.000 INCHES

90

39780

442

... More
FOR JOINTS THK. = 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS)

-

-

-

... More
NB 4.000 INCHES

100

44200

442

... More
NB 6.000 INCHES

2

884

442

... More
NB 12.000 INCHES

3

2592

864

... More
NB 18.000 INCHES

4

5184

1296

... More
FOR JOINTS ABOVE THK. 8MM

-

-

-

... More
NB 4.000 INCHES

4

1768

442

... More
NB 6.000 INCHES

4

1768

442

... More
NB 8.000 INCHES

62

35712

576

... More
NB 10.000 INCHES

35

25200

720

... More
NB 12.000 INCHES

85

73440

864

... More
NB 14.000 INCHES

4

4032

1008

... More
NB 16.000 INCHES

4

4896

1224

... More
NB 18.000 INCHES

7

9072

1296

... More
NB 20.000 INCHES

26

37440

1440

... More
NB 24.000 INCHES

27

46656

1728

... More
NB 26.000 INCHES

6

10800

1800

... More
NB 28.000 INCHES

24

47520

1980

... More
NB 30.000 INCHES

18

37260

2070

... More
NB 36.000 INCHES

5

11250

2250

... More
NB 60.000 INCHES

3

12960

4320

... More
NB 66.000 INCHES

5

23760

4752

... More
DYE PENETRATION/MAGNETIC PARTICLE TEST Performance of magnetic particle/ dye penetrant test including supply of all necessary materials, equipment and labour for carrying out the work as per specification and directions of Engineer-in-Charge.

-

-

-

... More
DYE PENETRANT TEST

1600

14400

9

... More
MAGNETIC PARTICLE TEST

6000

108000

18

... More
PIPE SUPPORTS (FROM MATERIALS SUPPLIED ON FIM BASIS) Fabrication, erection(at all elevations) of pipe supports like shoes, cradles, hangers, clamps(of all sizes / thicknesses manufactured by forming method using die), turn buckles, saddles, guides, special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, returning surplus materials and scrap etc to owners storage points and completing work as per drawings, specifications and instructions of Engineer-in-charge.This job includes Modifications / rectifications, if required, and adjustment/ alignment during precommisioning, commisioning as per the instructions of Engineer-in-charge.

-

-

-

... More
DUMMY PIPE SUPPORTS FOR C.S (OWNER SUPPLIED)

1

41270

41270

... More
DUMMY PIPE SUPPORTS FOR S.S (OWNER SUPPLIED)

0.1

8972

89729

... More
PIPE SUPPORTS (FROM MATERIALS ISUUED ON FIM BASIS) Fabrication, erection(at all elevations) of pipe supports like shoes, cradles, hangers, clamps(of all sizes / thicknesses manufactured by forming method using die), turn buckles, saddles, guides, special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, and completing work as per drawings, specifications and instructions of Engineer-in-charge. This job includes Modifications / rectifications, if required, and adjustment/ alignment during precommisioning, commisioning as per the instructions of Engineer-in-charge.

-

-

-

... More
C.S STRUCTURAL STEEL (WITH FREE ISSUE MATERIAL)

90

3082860

34254

... More
S.S STRUCTURAL STEEL (WITH FREE ISSUE MATERIAL)

0.05

3067

61358

... More
A.S STRUCTURAL STEEL (WITH FREE ISSUE MATERIAL)

0.1

4362

43628

... More
STRESS RELIEVING Carrying out stress relieving of weld joints, including all types of attachment welds (corrosion pads, protection shields, supports, etc.), as applicable, on all types of piping as called for on shop/site fabricated already erected system including supply of all materials, consumables recording devices, insulation materials, instruments etc., providing all normal & special equipment and gadgets, skilled/unskilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of Engineer-in- Charge. Repeat performance due to defective stress relieving or any other account shall be on Contractor's cost. Payment shall be done only after submission and approval of charts. Stress relieving shall be followed by measurement of hardness and no separate payment shall be made for this. Note: Unit for stress relieving quantity is (Nos of circumferential weld joints)

-

-

-

... More
NB 0.750 INCHES

250

41000

164

... More
NB 1.000 INCHES

6

984

164

... More
NB 1.500 INCHES

4

656

164

... More
NB 2.000 INCHES

830

136120

164

... More
NB 3.000 INCHES

370

91020

246

... More
NB 4.000 INCHES

1500

492000

328

... More
NB 6.000 INCHES

480

235680

491

... More
NB 8.000 INCHES

380

248900

655

... More
NB 10.000 INCHES

370

303030

819

... More
NB 12.000 INCHES

1516

1490228

983

... More
NB 20.000 INCHES

70

114660

1638

... More
NB 24.000 INCHES

500

983000

1966

... More
NB 26.000 INCHES

225

479025

2129

... More
NB 28.000 INCHES

680

1559240

2293

... More
Ultrasonic Testing (UT) Performance of UT inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specifications and instructions of Engineer-in-Charge. UT shall be submitted to the Engineer-in-charge. (Repeat UT due to defective UT on repaired joints due to Contractor's fault and for additional UT necessitated due to poor performance of contractor's welders shall be done at contractor's cost) Note: Unit for UT quantity is 'Nos of circumferencial weld joints'.

-

-

-

... More
FOR JOINTS ABOVE THK. 8MM

-

-

-

... More
NB 6.000 INCHES

1

2025

2025

... More
NB 8.000 INCHES

21

43659

2079

... More
NB 10.000 INCHES

12

31188

2599

... More
NB 12.000 INCHES

26

81094

3119

... More
NB 14.000 INCHES

1

3639

3639

... More
NB 16.000 INCHES

1

4158

4158

... More
NB 18.000 INCHES

3

14034

4678

... More
NB 20.000 INCHES

7

36386

5198

... More
NB 24.000 INCHES

8

49896

6237

... More
NB 26.000 INCHES

1

6757

6757

... More
NB 28.000 INCHES

7

50939

7277

... More
NB 30.000 INCHES

6

46782

7797

... More
NB 36.000 INCHES

1

9356

9356

... More
NB 60.000 INCHES

1

15593

15593

... More
NB 66.000 INCHES

1

18711

18711

... More
MODIFICATION/EXTRA WORKS (IF ANY) Cutting, bevelling, fitup, welding of different sizes of CS/AS/SS/Higher Alloy piping of all types and thicknessess in shop, in position, on ground/overhead on rack and at all elevations; transportation of pipes, fittings, flanges etc from owner's storage point to work site/ work shop, making necessary scaffoldings, consumables, machinery, tools, tackles, labour and supervision including attending repairs for completing the work as per the instruction of Engineer-in-charge.

-

-

-

... More
FLAME CUTTING C.S PIPING IBR/NON IBR

2000

172000

86

... More
HACKSAW CUTTING C.S PIPING IBR/NON IBR

680

85680

126

... More
BEVELLING C.S PIPING IBR/NON IBR

2950

250750

85

... More
FITUP & WELDING C.S PIPING IBR/NON IBR

2950

1330450

451

... More
FLAME CUTTING S.S PIPING IBR/NON IBR

63

9261

147

... More
HACKSAW CUTTING S.S PIPING IBR/NON IBR

20

4700

235

... More
BEVELLING S.S PIPING IBR/NON IBR

73

12264

168

... More
FITUP & WELDING S.S PIPING IBR/NON IBR

73

62926

862

... More
FLAME CUTTING A.S PIPING IBR/NON IBR

9

981

109

... More
HACKSAW CUTTING A.S PIPING IBR/NON IBR

4

680

170

... More
BEVELLING A.S PIPING IBR/NON IBR

11

1133

103

... More
FITUP & WELDING A.S PIPING IBR/NON IBR

11

7480

680

... More
REMOVAL ERECTED PIPING (ABOVE GROUND) Removal of piping existing/ erected including SW valves for modification as required as per Drawings/P&IDs/instructions of Engineer- in-charge at all elevations, including providing assistance to owner for draining, cleaning and purging of the lines to be removed , unbolting of flanged joints /cutting of pipe lines wherever required, installation of flanges and blind flanges, removal of insulation from insulated lines, removing supports, steam tracers, all fittings and flanges, instruments etc, cutting of pipes in appropriate length for transporting purposes, cleaning, flushing, drying and transporting all materials to storage point(within the complex battery limits) designated by Owner/EIL including stacking of material and disposing of waste etc as instructed by Engineer-in-charge.

-

-

-

... More
C.S/A.S PIPING

16600

1460800

88

... More
S.S PIPING

600

73200

122

... More
CALLIBRATION OF SAFETY VALVES Cleaning, set pressure tests of pressure relief and thermal relief valves before installation, providing equipments, necessary test jig, instrument air, nitrogen cylinders, all consumables including dropping / shifting of the PSV's/TSV's from the installed position (if required) to workshop for calibration/re-calibration/re-checking, etc., and reinstall back to original location including parts replacement, gasket, stud/bolts etc., re-fixing of the PSV's /TSV's including lapping (if required) but excludes flow calibration, calibration/test reports and excluding supply of valves. Note : Size mentioned below are Safety Valve Inlet Size

-

-

-

... More
NB 0.750 INCHES

1

810

810

... More
NB 1.000 INCHES

6

4860

810

... More
NB 1.500 INCHES

1

1215

1215

... More
NB 8.000 INCHES

1

6480

6480

... More
PIPE DAVITS Supply, fabrication & erection of pipe davits as per EIL std. 7-12-023 for lowering of aircooler motors/safety valves from structural platforms, fixing the same to platforms, inspection as per specs., supply of all necessary materials, equipment, consumables, labour, supervision etc. The work shall be carried out as per the specifications, drawings & instruction of engineer in charge.

0.2

19426

97133

... More
CLOSE PROXIMITY RADIOGRAPHY Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specifications and instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineerin-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Agencyr's fault and for additional radiography necessitated due to poor performance of Agencyr's welders shall be done at Agency's cost). Note : Unit for radiography quantity is 'Nos of circumferential weld joints', and rates are also inclusive of scaffoldings wherever required.

-

-

-

... More
FOR JOINTS THK. = 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION)

-

-

-

... More
NB 3.000 INCH

3

2382

794

... More
NB 4.000 INCH

11

8734

794

... More
NB 6.000 INCH

7

5558

794

... More
FOR JOINTS THK. = 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS)

-

-

-

... More
NB 4.000 INCH

10

7940

794

... More
FOR JOINTS ABOVE THK. 8MM

-

-

-

... More
NB 8.000 INCH

8

7616

952

... More
NB 10.000 INCH

4

4764

1191

... More
NB 12.000 INCH

10

11910

1191

... More
NB 18.000 INCH

1

1985

1985

... More
NB 20.000 INCH

1

1985

1985

... More
NB 24.000 INCH

3

7143

2381

... More
NB 26.000 INCH

1

2778

2778

... More
NB 28.000 INCH

3

8334

2778

... More
NB 30.000 INCH

1

3175

3175

... More
DIGITAL RADIOGRAPHY Performance of Digital Radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per requirements specified in the piping scope of work, Digital Radiography procedures B269-000-6-41-NDT-0001 and instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-inCharge. (Repeat radiography due to defective radiograph on repaired joints due to contractor's fault and for additional radiography necessitated due to poor performance of Agency's welders shall be done at Agencyr's cost). Note: 1. Unit for radiography quantity is "Nos. of circumferential weld joints". 2. Digital Radiography is applicable to Process Piping.

-

-

-

... More
FOR JOINTS THK. = 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION)

-

-

-

... More
NB 0.750 INCH

7

5558

794

... More
NB 2.000 INCH

20

15880

794

... More
NB 3.000 INCH

17

13498

794

... More
NB 4.000 INCH

70

55580

794

... More
NB 6.000 INCH

45

35730

794

... More
FOR JOINTS THK. = 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS)

-

-

-

... More
NB 2.000 INCH

1

794

794

... More
NB 4.000 INCH

60

47640

794

... More
NB 6.000 INCH

1

794

794

... More
NB 12.000 INCH

1

1191

1191

... More
NB 18.000 INCH

1

1985

1985

... More
FOR JOINTS ABOVE THK. 8MM

-

-

-

... More
NB 4.000 INCH

1

794

794

... More
NB 6.000 INCH

1

794

794

... More
NB 8.000 INCH

50

47600

952

... More
NB 10.000 INCH

25

29775

1191

... More
NB 12.000 INCH

60

71460

1191

... More
NB 14.000 INCH

1

1588

1588

... More
NB 16.000 INCH

3

4764

1588

... More
NB 18.000 INCH

5

9925

1985

... More
NB 20.000 INCH

15

29775

1985

... More
NB 24.000 INCH

20

47620

2381

... More
NB 26.000 INCH

4

11112

2778

... More
NB 28.000 INCH

15

41670

2778

... More
NB 30.000 INCH

11

34925

3175

... More
NB 36.000 INCH

4

14288

3572

... More
NB 60.000 INCH

1

5954

5954

... More
NB 66.000 INCH

4

26988

6747

... More
Installation of Pre-insulated SS Tubing for Steam Tracing Transportation of all related preinsulated tubing materials from owners storage point to work site / workshop; fabrication, erection, supporting, testing etc., of Pre insulated SS Tubing from the Steam supply distribution manifold outlet upto the traced pipe & from the traced pipe to the Condensate Recovery manifold including supply of all enabling materials (including adaptor for joining tube with CS pipe),clamps, supports etc.; including tube bending, cutting, end preparation, making connections, supporting etc. as per specification (B269-6-44-0022),manufacturer specification, standard & guidelines etc. with all other tools and tackles including bending/crimping tools, sealing kits etc., skilled manpower including adequate prevention from dust contamination etc. to complete the work in all respect at all elevations as per the directions of the Engineerin-Charge

-

-

-

... More
Pre-insulated SS tubing

-

-

-

... More
0.5 INCH (WITH LP STEAM )

5050

2514900

498

... More
0.5 INCH (WITH MP STEAM)

12600

6274800

498

... More
0.75 INCH (WITH LP STEAM)

13

6474

498

... More
0.75 INCH (WITH MP STEAM)

13

6474

498

... More
Installation of pre-fabricated Hook-ups on the line Welding of First joint of Prefabricated hook- ups on pipe / equipment / orifice flange / flow-meter end, Welding of end connection on tapping / Pre-fabricated hook-ups, seal run of threaded connection including erection of supports, mounting of instrument stanchions (2" pipe) through pipe clamp / Brackets (if required), performing Positive Material Identification (PMI) using alloy analyzers and performing Radiography on all welds. PWHT to be done wherever applicable as per the piping class. Transportation of all items from Owner's storage point to work site/ workshop. Welding/ fixing of pipe clamps, instrument stanchion. Prefabricated hook-up welding on pipe shall be of dissimilar material. Material of Pre-fabricated hook-ups shall be SS (316/321).

-

-

-

... More
Flow assembly with 0.5" TH connection (without PWHT)

6

4320

720

... More
Pressure assembly with 0.75" SW connection (without PWHT)

6

6480

1080

... More
Transportation of parts of the assembly of Vortex Flow Meter, Venturi Type Flow Meter, Ultrasonic Flow Meter, Coriolis Mass Flowmeter, Thermal Mass Flow meter along with integral control valve ,Thermal Mass flowmeter, Integral Orifice Flowmeter, Flow Nozzles, Averaging Pitot Tubes for Flow messurement, Magnetic Flowmeter, Ultrasonic Spool Piece meter, Ultrasonic Insertion type flowmeter (the asembly will consists of instrument strainers, air eliminators, volume bottles, spool piece, inserts etc.) from Owner storage points to Agencyr's store/worksite and installation of the assembly of all ratings including assembly of all parts and fixing of gaskets, bolts, nuts wherever required, as per drawings, specifications, and directions of Owner/Engineer-in-Charge.

-

-

-

... More
Ultrasonic Flow meter

-

-

-

... More
18" line size ( Rating 150#)

1

11340

11340

... More
84" line size ( Rating 150#)

1

52920

52920

... More
90" line size ( Rating 150#)

1

56700

56700

... More
Vortex flow meter

-

-

-

... More
1" line size (Rating 150#)

1

630

630

... More
Flow Nozzle

-

-

-

... More
2" line size(Rating 150#)

1

1260

1260

... More
Supply of Flame proof torches- rechargeable (with high intensity)

6

50628

8438

... More
Supply of 40/80 wire-mesh SS for covering strainers/filters

60

40500

675

... More
Supply of rubber hoses(1", 15 mtr length, pressure-500 psi)

11

49005

4455

... More
Supply of fire hoses with connector for fire hydrants (dia. 63 mm, length-15 mtr as per relevant international specifications)

7

48195

6885

... More
To and fro transportation of all electrical, instruments, mechanical items from site/store (EIL within 50 kmradius as per instruction of engineer-in charge. Suitable packing shall be included in quoted rates)

6720

114240

17

... More
Fabrication & installation of chain in valves as per EIL Std.7-44-0050 & as per the instruction of Engineer -in-Charge. material for the same shall be in contractor scope.

-

-

-

... More
NB 2 INCH - 6 INCH

4

15120

3780

... More
NB 8 INCH - 14 INCH

4

17640

4410

... More
NB 16 INCH - 24 INCH

1

7560

7560

... More
EQUIPMENT ERECTION Transportation of reactors, columns, vessels, silencers, heat exchangers (shell and tube, plate fin, plate) and electric heater etc. from owner's storage point to work site, assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs, erection of wooden pillow for cold equipments, stacking of multi-tier exchanger(which are stored in unstacked condition), arranging hooks for test ring/ test flanges in heat exchangers, installation of demister, internal gratings, distributor, pipe davit, installation of mixer/agitator, cleaning and flushing by water, draining, drying by compressed air, arranging all tools, tackles, machinery, consumables, transportation equipment, erection equipment, instruments, labour, ancillary, etc. to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge.

-

-

-

... More
Equipment weighing less than 500 MT but 100 MT and above

85

773840

9104

... More
Equipment weighing less than 30 MT but 10 MT and above

4

44324

11081

... More
Equipment weighing less than 10 MT

1

11081

11081

... More
ARCHITECTURE

-

-

-

... More
ROOFING

-

-

-

... More
Providing and fixing 40mm x 6mm M.S. FLAT WIND TIES over sheeting with anticorrosive polymer coated G.I. nuts, bolts, polymer cap, seal and thrust washers of approved make iincluding painting with two coats of synthetic enamel paint of approved make over a coat of approved quality red oxide zinc chromate primer etc.all complete.

10

3290

329

... More
Providing and laying in position approved quality profiled, precoated, steel sheets (for roofing, cladding etc.) made from cold rolled high tensile Zincalume/ Galvalume Steel of 550 MPA yield stress conforming to IS:513, IS:15961 and ASTM AS: 1397; the substrate shall be hot dip metallic coating of aluminium- zinc alloy (150 grams per sq. mtr. Total on both sides, coating class AZ150); the bottom unexposed surface shall be provided with alkyd backer of minimum 5 microns over a 5 micron coat of primer; top exposed surface shall have SDP (Super Durable Polyester) paint system MINIMUM 20 microns in approved shade applied over 5 microns primer; overall coated thickness of sheets not less than 0.52 mm having base metal thickness of minimum 0.45mm (negative tolerance not acceptable), profile depth not less than 28mm and pitch of 195 to 255mm; including cutting, mitering, laps, providing cutouts for fixing accessories, necessary fastners (approved quality anti corrosive polyester polymer coated, rivets, nuts, bolts, self drilling screws/ fasteners with integral washers and EPDM seals, and nylon colour caps and natural cure type joint sealants etc.) All complete as per approved manufacturer's specifications. Note: The steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg name, etc) on back side at regular interval confirming genuinity of the material.

45

40275

895

... More
Providing and laying in position roofing and cladding accessories like ridge piece, corner piece, north light curve piece, apron piece, gutter, flashing etc. fabricated out of 0.5mm precoated Zincalume/ Galvalume Steel steel sheets of same material/ quality etc. as that of sheeting; bent and profiled to match with the roofing and cladding, including all cutting, fabrication, rivetting, fastners etc. all complete.

11

9845

895

... More
Polycarbonate sheets roofing/ cladding Providing and fixing in position (for roofing and cladding) machine made 2mm thick corrugated polycarbonate sheets (conforming to IS :14434, 14443) of approved manufacturer (in approved shade) extruded from polycarbonate resin, having profiles as approved/ matching exactly with the surrounding pre-coated roofing/ cladding sheets and having following properties: (a) Specific gravity 1.2 g/ cm3 (b) Hardness 119 M Scale (c) Tensile Strength 64 Mpa (d) Compressive strength 66Mpa (e) Impact Strength 900 J/m The item includes fixing to steel structure members (truss/ purlins)/ brick masonry walls by means of polymer coated 'J' or 'L' hooks, bolts, nuts 8mm dia G.I. bitumen washers etc. all complete as per approved manufacturer's recommendations and specifications.

7

10381

1483

... More
EARTH WORK (REFER SPECIFICATION NO. 6-68-0003)

-

-

-

... More
Earthwork excavation in soil

-

-

-

... More
Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.

2380

283220

119

... More
Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.

215

31390

146

... More
Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 3.0m and upto & inclusive of 4.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting.

9

1557

173

... More
Transporting & Disposing the SURPLUS EARTH AND DEBRIS

-

-

-

... More
Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids).

20

1620

81

... More
Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids).

970

78570

81

... More
"Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction areas to areas ANYWHERE OUTSIDE THE PLANT BOUNDARY, including re-excavating the deposited soil excavated earlier, loading, transportation, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). DISPOSAL AREAS OUTSIDE PLANT BOUNDARY TO BE ARRANGED BY THE CONTRACTOR. Royalty as applicable for disposal outside plant limits to be borne by the Contractor."

8

1480

185

... More
SHORING AND STRUTTING

-

-

-

... More
Providing and installing approved type of "SHORING & STRUTTING" by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed.

20

3780

189

... More
Providing and installing approved type of "SHORING & STRUTTING" by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed.

20

5280

264

... More
BACKFILLING AFTER EXECUTION OF WORK

-

-

-

... More
BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete.

1580

135880

86

... More
BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete.

20

2160

108

... More
BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 500M AND UPTO & INCLUSIVE OF 1KM including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete.

13

1638

126

... More
DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012)

-

-

-

... More
Making cut-outs in RCC slab/ wall upto a thickness of 400mm (taking all necessary safety precautions) by vibration-less spark-free mechanical means like core-cutting, wet cutting by diamond wall saw system at all depths & heights including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, disposal of unserviceable material, plastering & finishing the cut surfaces, all complete as specified and directed by the Engineer-in- Charge (Measurement on Plan/ Elevation Area basis).

2

8100

4050

... More
Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed.

4

4536

1134

... More
Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps ANYWHERE OUTSIDE THE PLANT BOUNDARY, all complete as specified and directed. Disposal areas outside plant Boundary to be arranged by the contractor. Royalty as applicable for disposal outside plant limits to be borne by the Contractor. (Excavation & backfilling shall be paid separately under relevant items).

4

4456

1114

... More
Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps ANYWHERE OUTSIDE THE PLANT BOUNDARY, all complete as specified and directed. Disposal areas outside plant Boundary to be arranged by the contractor. Royalty as applicable for disposal outside plant limits to be borne by the Contractor. (Excavation & backfilling shall be paid separately under relevant items).

4

4536

1134

... More
Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, upto & inclusive of 25mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items).

2

338

169

... More
Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, beyond 25mm and upto & inclusive of 50mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items).

2

474

237

... More
Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, beyond 50mm and upto & inclusive of 100mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items).

2

676

338

... More
Chipping of RCC WORK (taking all necessary safety precaution) by CHISELLING for thickness more than 100mm for all depths below plinth level including supply of all tools & tackles, scaffolding, propping, underpinning, etc. exposing, cutting, lapping/welding the reinforcement bars as per drawings & cleaning the same by wire brushing, washing the exposed surfaces, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items).

2

3376

1688

... More
Chipping of RCC WORK (taking all necessary safety precaution) by CHISELLING for thickness more than 100mm for all heights above plinth level including supply of all tools & tackles, scaffolding, propping, underpinning, etc. exposing, cutting, lapping / welding the reinforcement bars as per drawings & cleaning the same by wire brushing, washing the exposed surfaces, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed.

2

4050

2025

... More
POCKETS - NON FIM ITEMS

-

-

-

... More
Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed.

8

1896

237

... More
PCC _ NON FIM ITEMS

-

-

-

... More
Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items)

4

2432

608

... More
Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed.

4

3376

844

... More
Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps ANYWHERE OUTSIDE THE PLANT BOUNDARY, all complete as specified and directed. Disposal areas outside plant Boundary to be arranged by the contractor. Royalty as applicable for disposal outside plant limits to be borne by the Contractor. (Excavation & backfilling shall be paid separately under relevant items).

4

3512

878

... More
STEEL WORKS - NON FIM ITEMS

-

-

-

... More
Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed.

2

11476

5738

... More
AC / GI SHEETS - NON FIM ITEMS

-

-

-

... More
Dismantling GI/asbestos/translucent sheets, ridges, gutters etc. (taking all necessary safety precautions) in roofings and wall claddings, including supply of all tools & tackles, necessary scaffolding, consumables, cutting (by flame or saw) of fixing hooks, transporting and stacking the serviceable materials, cleaning the site and disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete for all levels, as specified and directed.

25

2025

81

... More
MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013)

-

-

-

... More
BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE

-

-

-

... More
Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturer's specification for protection of reinforcement against corrosion. Supply of admixture in Agency's scope.

110

8910

81

... More
CUTTING RCC PILES - NON FIM ITEMS

-

-

-

... More
Cutting the heads of R.C.C. piles of diameter upto 600mm and a length not exceeding 1500mm including exposing/ cleaning, bending of the reinforcement, making site clean for casting of pile cap and removal of debris to the spoil heaps within the plant boundary etc. all complete as specified & directed. (Excavation; if any, to be measured separately under respective item).

4

3240

810

... More
BUILDING PILE HEADS - NON FIM ITEMS

-

-

-

... More
Providing and building up pile heads of diameter upto 600mm in RCC of grade M30 with 20mm and down size graded crushed stone aggregates/ gravel including all shuttering but excluding the cost of reinforcement (to be measured under respective item) all complete as directed.

2

9748

4874

... More
SAND FILLING - NON FIM ITEMS

-

-

-

... More
Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer- in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete .

22

25256

1148

... More
BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056)

-

-

-

... More
EPOXY RESIN - NON FIM ITEMS

-

-

-

... More
Providing and applying approved EPOXY RESIN (prepared as per manufacturer's recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items).

4

4320

1080

... More
FIREPROOFING OF STEEL STRUCTURES (REF SPEC NO 6-68-0033)

-

-

-

... More
Concrete - Non FIM Items

-

-

-

... More
Vermiculite Concrete for Structural Steel - Non-FIM Items

-

-

-

... More
Mechanical works

-

-

-

... More
Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed.

0.1

8037

80378

... More
DISMANTLING OF STEEL WORKS

-

-

-

... More
Dismantling structural steel already erected by others including provision of adequate temporary supports, bracings etc. wherever required, to ensure safety of the affected structure or part thereof, and replacing back all original members into their respective positions true to line and level, removing all temporary supports/bracings, welding/bolting of the end connections, splicing or strengthening the member and their joints to regain original strengths, all complete as directed by the Engineer-in-Charge. Note: The weight of dismantled and re- erected structure shall be measured only once.(SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE)

2

13006

6503

... More
PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004)

-

-

-

... More
PCC - NON FIM ITEMS

-

-

-

... More
Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE AGENCY

45

161820

3596

... More
Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE AGENCY

8

35984

4498

... More
RCC SUBSTRUCTURE - NON FIM ITEMS

-

-

-

... More
Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.

100

552300

5523

... More
Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE AGENCY.

9

50265

5585

... More
RCC SUPERSTRUCTURE - NON FIM ITEMS

-

-

-

... More
Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.

70

417690

5967

... More
PRECAST ELEMENTS - NON FIM ITEMS

-

-

-

... More
Manufacturing, transporting, supplying and erecting in position Reinforced Cement Concrete PRECAST ELEMENTS such as manholes, catch-basins, pits, pipe sleepers, box-culverts, drains, trenches, etc. of M-30 grade with 20mm and down size graded crushed stone aggregates/ gravel, each unit beyond 1000 kg and upto and inclusive of 3000 kg. for all leads, levels below plinth, shapes and thickness including all moulds, shuttering and centering, vibrating, tamping, curing, chamfering wherever required, providing lifting hooks, metal inserts, making holes, pockets, (only M.S. inserts to be measured & paid separately) transporting to site, erecting, levelling, aligning and fixing in position with cement mortar 1:3 (Cement : 3 Coarse Sand), breaking bricks and/ or concrete surfaces and making good the same etc. all complete (excluding the Cost of Reinforcement) and as directed. All materials including cement supplied by the contractor.

144

1079568

7497

... More
Manufacturing, transporting, supplying and erecting in position Reinforced Cement Concrete PRECAST ELEMENTS such as columns, beams, cover slabs, lintels, louvers, fins, shelves etc. of M-30 grade with 20mm and down size graded crushed stone aggregates/gravel, each unit upto and inclusive of 500 kg. for all leads, levels, shapes and thickness including all moulds, shuttering and centering, vibrating, tamping, curing, chamfering wherever required, finishing the top surface with cement mortar 1:3 ( 1 Cement : 3 Sand) to give a smooth and even surface, or non skid finish as specified, providing lifting hooks, metal inserts, making holes pockets, (only M.S. inserts to be measured & paid separately) transporting to site, erecting, levelling, aligning and fixing in position with cement mortar 1:3 ( Cement : 3 Coarse Sand), breaking bricks and/or concrete surfaces and making good the same etc. all complete (excluding the Cost of Reinforcement ) and as directed. All materials including cement supplied by the contractor.

2

15876

7938

... More
Manufacturing, transporting, supplying and erecting in position Reinforced Cement Concrete PRECAST ELEMENTS such as columns, beams, cover slabs, lintels, louvers, fins, shelves etc. of M-30 grade with 20mm and down size graded crushed stone aggregates/gravel, each unit beyond 500 kg and upto and inclusive of 1000 kg. for all leads, levels, shapes and thickness including all moulds, shuttering and centering, vibrating, tamping, curing, chamfering wherever required, finishing the top surface with cement mortar 1:3 ( 1 Cement : 3 Sand) to give a smooth and even surface, or non skid finish as specified, providing lifting hooks, metal inserts, making holes pockets, (only M.S. inserts to be measured & paid separately) transporting to site, erecting, levelling, aligning and fixing in position with cement mortar 1:3 (1 Cement : 3 Coarse Sand), breaking bricks and/or concrete surfaces and making good the same etc. all complete (excluding the Cost of Reinforcement ) and as directed. All materials including cement supplied by the Agency.

2

15876

7938

... More
HYD BARS / MS BARS - NON FIM ITEMS

-

-

-

... More
Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D TMT conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN AGENCY'S SCOPE.

30

1688850

56295

... More
CONC. ENCASING - NON FIM ITEMS

-

-

-

... More
Providing and laying Reinforced Cement Concrete of grade M-30 with 20mm and down size graded stone aggregates for ENCASING OF STRUCTURAL STEEL WORK including chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (excluding the cost of Reinforcement and Shuttering) for all heights and depths in any shape, position, and thickness etc. all complete as specified and shown. Cement. All materials supplied by the Agency.

2

11826

5913

... More
CENTERING & SHUTTERING - NON FIM ITEMS

-

-

-

... More
Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment / machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed.

1170

321750

275

... More
Providing and fixing CENTERING & SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments, columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed.

480

216000

450

... More
EXPANSION JOINTS - NON FIM ITEMS

-

-

-

... More
Providing 20mm wide EXPANSION JOINTS in flooring and pavement slabs and ISOLATION JOINTS around equipment foundations / columns / pedestal / trenches etc. including cleaning the joints of all loose material, filling clean sand for the full depth of slab (upto and inclusive of 300 mm) except for 12mm depth from top and sealing the top 12mm with approved two part liquid polysulphide Sealing Compound as per IS:12118 etc. all complete as shown, specified and directed.

45

5175

115

... More
MECHANICAL REBAR COUPLERS - NON FIM ITEMS

-

-

-

... More
"Supplying and fixing MECHANICAL REBAR COUPLER of approved make for jointing high strength deformed steel reinforcement bars of Grade Fe500D (conforming to IS:1786) of dia. upto and inclusive of 25 mm at all levels & locations including testing as per manufacturer's recommendations, adjusting etc. all complete as specified and directed.

9

8262

918

... More
Supplying and fixing MECHANICAL REBAR COUPLER of approved make for jointing high strength deformed steel reinforcement bars of Grade Fe500D (conforming to IS:1786) of dia. above 25 mm at all levels & locations including testing as per manufacturer's recommendations, adjusting etc. all complete as specified and directed.

9

10332

1148

... More
FIXING RE-BARS IN ALREADY CAST CONCRETE - NON FIM ITEMS

-

-

-

... More
Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. upto 12 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturer's recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN AGENCY'S SCOPE EXCLUDING REINFORCEMENT BARS.

20

9180

459

... More
Designing, supplying and fixing REBARS in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 16 mm & 20 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturer's recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN AGENCY'S SCOPE EXCLUDING REINFORCEMENT BARS.

20

9180

459

... More
Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 25 mm & 28 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturer's recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN AGENCY'S SCOPE EXCLUDING REINFORCEMENT BARS.

25

11475

459

... More
SAFETY (REFER EIL SPECIFICATION)

-

-

-

... More
Safety Structures - Non FIM Items

-

-

-

... More
Supplying, Transporting, Storing, Fabricating & Erecting in position and testing/ examining bolted and/ or welded Structural Steel Works at all locations and levels in HANGER SCAFFOLDING below piperack, comprising of hangar channels, fabricated pen wen ladder beams, steel planks bent to shape and size and any other sections, if required, all as per sketches/ specifications and load tested for statisfactory performance, including cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, including preparation and submission of detailed fabrication drawings, preparing the surface for painting as per BIS codes after fabrication etc. all complete as specified and directed. All items shall be removed & carried back by Contractor as per instructions of Engineer-in-Charge after completion of works. (Supply of All Material In Contractor's Scope).

140

289240

2066

... More
Covering of existing openings in buildings with 6 mm thick MS chequered plates by stitch welding (12 mm @ 500 mm centres) to the existing steel framework and in case existing MS framework is not available, by providing necessary anchor fastner (Mechanical) in concrete/ brick wall etc., including cutting, grinding edges, hoisting, fixing in position all complete as per the directions of Engineer-in-Charge. Rate is inclusive of supply of all materials and consumables.

320

30080

94

... More
Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers.

420

51240

122

... More
Providing of steel scaffold stair tower system with minimum 800 mm wide flights, landings at every 1.5 to 2.0 m height, handrailing around flights and landings for safe access upto a height of 12.0 m, all complete including supply of all materials, tools & tackles, manpower etc., at the location directed by Engineer-in-Charge on monthly rental basis. Rental charges shall be payable after completion of erection of the system and acceptance by the Engineer-in-Charge. Rates shall also be inclusive of dismantling of the system and taking out all materials from the project permises as directed by the Engineer-in-Charge. Rate quoted shall be for Running Meter (Height) per month.

42

144606

3443

... More
STRUCTURAL STEEL WORKS SPEC NO. 6-68-0006

-

-

-

... More
General Steel Works - FIM Items

-

-

-

... More
Dismantling, modification & re-erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS ALREADY ERECTED BY OTHERS at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, repair of damaged portion of primer as per Sl No 7.2.1 of Table 7.2 of Standard Specification for Surface Preparation and Protective Coating Document No. 6-79-0020 (or as per Job Specification, wherever applicable), grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. SUPPLY OF ALL OTHER MATERIAL (OTHER THAN ALREADY ERECTED STRUCTURAL STEEL) IN CONTRACTOR'S SCOPE.

2

41310

20655

... More
Dismantling, modification & re-erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS ALREADY ERECTED BY OTHERS at all locations and levels MORE THAN 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, repair of damaged portion of primer as per Sl No 7.2.1 of Table 7.2 of Standard Specification for Surface Preparation and Protective Coating Document No. 6-79-0020 (or as per Job Specification, wherever applicable), grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. SUPPLY OF ALL OTHER MATERIAL (OTHER THAN ALREADY ERECTED STRUCTURAL STEEL) IN CONTRACTOR'S SCOPE.

2

42750

21375

... More
Transporting, Assembling and Erecting in position bolted and/ or welded already fabricated Structural Steel works (of any Grade) at all levels & locations, comprising of rolled/ built-up sections made of joists, channels, angles, flats rounds, plates cut and/ or bent to any shape and size, in beams, girders, trusses columns, brackets, bracings, ladders (with or without cage), safety chain brackets, staircases, handrailings and platforms of any shape and size (including chequered plates/ gratings), on vertical and/ or horizontal equipments, in miscellaneous valve operating platforms, pipe supports etc, fixing in line and level with temporary staging and removal of the same after erection, grouting below base plates with free flow non shrink/ ordinary grout as specified to bring them to required levels, all complete as shown, specified and directed. ALREADY FABRICATED STRUCTURAL STEEL SHALL (WITH CONNECTION BOLTS) BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTOR'S SCOPE.

7

74816

10688

... More
General Steel Works - Non FIM Items

-

-

-

... More
Taking delivery, Fabricating at Shop outside the plant boundary, transporting fabricated items to site, unloading, storing, erecting in position and testing/ examining, bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E250A / E250BR / E250B0 (conforming to IS:2062 at all locations and levels UPTO & INCLUSIVE OF 20 M ABOVE HPP/ FGL including all builtup sections/ compound sections made out of rolled sections and/or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified all complete. SUPPLY OF STRUCTURAL STEEL IS EXCLUDED FROM AGENCY'S SCOPE.

27

513324

19012

... More
Taking delivery, Fabricating at shop outside the plant boundary, transporting fabricated items to site, unloading, storing, erecting in position and testing/ examining, bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E250A / E250BR / E250B0 (conforming to IS:2062 at all locations and levels MORE THAN 20 M ABOVE HPP/ FGL including all builtup sections/ compound sections made out of rolled sections and/or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified all complete. SUPPLY OF STRUCTURAL STEEL IS EXCLUDED FROM AGENCY'S SCOPE.

11

223234

20294

... More
STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007)

-

-

-

... More
Yst310 IS 4923

-

-

-

... More
Taking delivery, transporting, storing, fabricating, erecting in position & testing / examining at all locations and levels, bolted and/or welded STRUCTURAL STEEL WORKS of all types using COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS: 4923, Grade Yst-310 of approved make in all type of trusses, purlins, girders, side rails, columns, runners, beams, ties, portals, framework, bracing, brackets, sagrods etc. including all handling straightening/bending if required, cutting to required size & shape, edge preparation, welding & bolting of joints, providing and fixing end caps and plugging holes, fixing in line and level with necessary temporary staging and removal of the same after erection, grouting with Ordinary/ premix free flow Non-Shrink Grout as specified all complete as specified and directed (SUPPLY OF STRUCTURAL STEEL IS EXCLUDED FROM AGENCY'S SCOPE).

15

304410

20294

... More
MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008

-

-

-

... More
Anchor Bolts - Non FIM Items

-

-

-

... More
Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN AGENCY'S SCOPE).

1

84150

84150

... More
MS Metal Inserts - Non FIM Items

-

-

-

... More
Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable) etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN AGENCY'S SCOPE).

3

241134

80378

... More
GI Pipe Sleeves - Non FIM Items

-

-

-

... More
Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement / any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed.

1

91800

91800

... More
MS Chequered Plates - Non FIM Items

-

-

-

... More
Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN AGENCY'S SCOPE).

1

79186

79186

... More
MS Grating Cat. A,B - Non FIM Items

-

-

-

... More
Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED GALVANISED GRATING (purchased from approved manufacturer of the Owner) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) and EIL Standard No. 7-65-0206 (in catch basins, drains, etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturer's supplied galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed (SUPPLY OF ALL MATERIALS IN AGENCY'S SCOPE).

4

375840

93960

... More
Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings.

4

2592

648

... More
MS Rungs - Non FIM Items

-

-

-

... More
Supplying, fabricating, fixing and keeping in position M.S. RUNGS in R.C.C. works at all depths and heights including handling, transporting the steel to site workshop and site of work, straightening, if required, cutting, bending to shape, necessary tying and welding with reinforcement, adjustment of shuttering, cleaning, surface preparation, shop primer as per EIL Spec. 6-79-0020 (or Job Specification, wherever applicable) and two coats of anticorrosive paint of approved quality on the exposed portion of rungs etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN AGENCY'S SCOPE).

11

990

90

... More
Hand Railing 1000mm - Non FIM Items

-

-

-

... More
Supplying, fabricating and fixing in position at all locations 1000 mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32 mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS:4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable) etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN AGENCY'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).

45

72135

1603

... More
Supplying, fabricating and fixing in position at all locations 1000 mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500 mm c/c) with 32 mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable) etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).

90

156060

1734

... More
Hand Railing 500mm - Non FIM Items

-

-

-

... More
Supplying, fabricating and fixing in position at all locations 500mm HIGH INCLINED HAND RAILING (for stair cases) consisting of top rail & vertical posts (maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable) etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN AGENCY'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).

22

34584

1572

... More
Supplying, fabricating and fixing in position at all locations 500mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable) etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN AGENCY'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).

45

67005

1489

... More
Mechanical Anchor fastners - Non FIM Items

-

-

-

... More
Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.

45

15525

345

... More
Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 20mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.

22

12628

574

... More
Chemical Anchor Fastner

-

-

-

... More
Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be used with the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.

22

24420

1110

... More
Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be used with the help of dispenser, of 24mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed.

22

41250

1875

... More
BRICK MASONRY (REFER SPECIFICATION NO.6-68-0009)

-

-

-

... More
CLASS 10.0 at all depths -Non FIM Items

-

-

-

... More
Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 10.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/ curved brick masonry) at all depths below plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/ slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.

4

17300

4325

... More
Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 10.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/ curved brick masonry) at all heights above plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/ slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR.

2

9360

4680

... More
GENERAL CIVIL

-

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
Supply and installation of Combined Safety Shower and Eyewash units as per Spec. No. 6-66-0038, including providing and fixing of necessary foundation bolts in foundations / pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge.

1

36000

36000

... More
Installation of Expansion Bellow as per specification comprising of rubber expansion bellow in position including taking delivery, transportation of the material to work site, as per directions of Engineer-in-Charge. For following nominal size and piping class

-

-

-

... More
Dia 60 Inch Piping Material Class A93A

3

162000

54000

... More
Dia 20 Inch Piping Material Class A93A

1

13500

13500

... More
Restriction Orifice

-

-

-

... More
Supplying of Restricted Orifice Plate including manufacture, delivery to owner's storage point all complete as data sheet, specifications, drawings and directions of Engineer-in-Charge. For following nominal sizes of pipes and Piping material class.

-

-

-

... More
Nominal Dia. 4 Inch Piping Material Class A91Y

115

177675

1545

... More
Nominal Dia. 2 Inch Piping Material Class J92A

1

949

949

... More
Nominal Dia. 3 Inch Piping Material Class J92A

1

1148

1148

... More
Nominal Dia. 4 Inch Piping Material Class J92A

1

1545

1545

... More
Nominal Dia. 8 Inch Piping Material Class J92A

1

3290

3290

... More
Nominal Dia. 12 Inch Piping Material Class J92A

1

7956

7956

... More
Nominal Dia. 6 Inch Piping Material Class J92A

3

7116

2372

... More
Fabrication and Erection of piping (underground)

-

-

-

... More
Laying and joining of externally 3LPE Pre-coated Carbon Steel Pipes and specials underground including transportation of all material from Owner's storage point to worksite, earthwork in excavation in all types of soils excluding soft rock and hard rock for pipe trenches, saddles, etc. including dewatering, shoring and strutting if required, dressing of sides, levelling, grading and ramming of bottoms, cutting of pipes to required lengths if required, edge preparation, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments,, fixing of nuts, bolts, gaskets and washers, welding, carrying out repairs of coating defects not attributed to owner (i.e. defects occurring after taking over of pipes from owner), Liquid epoxy coating (EP) as per DIN EN 10289, Class C, Type 3 of all field weld joints (at pipes, bends, fittings, valves, flanges etc.) as per specification including supply of coating material, inspection and testing for the corrosion protection coating as per specification, cutting of road wherever required and making good the same, hydrostatic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including reexcavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part- VII or 85% relative density as per IS: 2720 part XIV as applicable, making good the surface, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipes and specials to owner's storage point. (All the materials except Pre-coated Pipes and fittings shall be supplied by the Agency. Pre-coated Pipes and fittings shall be issued free of cost by the Owner.) (Depth of excavation for pipe trench shall be upto 3.0m)

-

-

-

... More
Carbon Steel Piping (Non IBR), Thickness =10 mm

-

-

-

... More
Fabrication, For the following nominal sizes

-

-

-

... More
NB 2 inch - 6 inch

230

89010

387

... More
NB 8 inch - 14 inch

190

73530

387

... More
NB 16 inch - 24 inch

2450

948150

387

... More
NB 26 inch - 36 inch

120

46440

387

... More
Erection including corrosion protection coating of field joints, for Water System (Pressure Piping), For following Nominal Sizes

-

-

-

... More
NB 2 inch - 6 inch

1081

328624

304

... More
NB 8 inch - 14 inch

1600

430400

269

... More
NB 16 inch - 24 inch

51275

13382775

261

... More
NB 26 inch - 36 inch

700

182700

261

... More
Supply, fabrication and Erection of piping (underground)

-

-

-

... More
Supply and Laying of U/G PPR pipe for Water Services

-

-

-

... More
Supplying, laying and fixing 3 Layer PP-R (Poly Propylene Random copolymer) pipes underground. Pipes shall conform to IS:15801; SDR 7.4 U V stabilized & antimicrobial fusion welded, having thermal stability for hot & cold water supply, including supply and fixing of all PP-R plain & brass threaded polypropylene random fittings, PP-R Male adopters, bends, elbows, tees, reducers, sockets, unions and other specials, cutting pipes to required lengths, making connections, jointing, earthwork in excavation for pipe trenches, etc. in all types of soil excluding soft rock and hard rock including dewatering, shoring and strutting if required, dressing of sides, levelling, grading and ramming of bottoms, including laying of pipes in trenches, hydrostatic testing of the piping, backfilling the trenches with selected/approved earth fill material, cutting of roads wherever required, making good the road surface after laying, disposal of surplus earth at a designated area anywhere within complex limit etc. all complete as per drawings, manufacturer specifications and directions of Engineer-in-Charge. For the following Nominal Bore (NB) pipe:

-

-

-

... More
Nominal Dia. 160 mm

22

98208

4464

... More
Nominal Dia. 200 mm

22

159984

7272

... More
Nominal Dia. 75 mm

22

26136

1188

... More
Nominal Dia. 110 mm

22

48312

2196

... More
Water System Galvanised Pressure Piping (Under Ground) (Screwed)

-

-

-

... More
Supplying and laying Carbon Steel Galvanised Pipes as per piping materials specification Class underground including supply of all necessory fittings including Tee, reducing Tee, reducing Coupling, nipple, coupling, elbows etc. supply of teflon tapes, PTFE tape, white lead, etc. cutting the pipes to required lengths, making threads, earthwork in excavation for trenches, etc. in all types of soil except soft rock & hard rock including dewatering, shoring and strutting if required, dressing of sides, levelling, grading and ramming of bottoms, including laying of pipes in trenches, jointing the pipes and fittings with threaded connections, hydrostatic testing of the piping, backfilling the trenches with selected/approved earth fill material, cutting of roads wherever required, making good the road surface after laying, disposal of surplus earth at a designated area anywhere within complex limit etc., complete as per specifications, drawings and directions of Engineer-in-Charge. For following Nominal Size and Piping Material Class.

-

-

-

... More
Nominal Dia 2 Inch Piping class J92A

4

10332

2583

... More
Nominal Dia 3 Inch Piping class J92A

4

13360

3340

... More
Nominal Dia 4 Inch Piping class J92A

9

40059

4451

... More
Nominal Dia 1 Inch Piping class J92A

360

629280

1748

... More
Supplying and laying Carbon Steel Galvanized Pipes for Fire water spray system/ sprinkler system/ detection system as per piping material specification, UNDER GROUND, including supply of all necessary fittings such as tees, reducing tees, reducing couplings, couplings, elbows, nipples, Teflon tapes, PTFE tape, white lead etc., cutting the pipes to required lengths, making threads, including laying of pipes in RCC TRENCHES, joining of pipes and fittings with threaded/flanged connection, gaskets and bolts, hydrostatic testing of the piping including supply of necessary fittings etc. complete as per specifications, drawings and instructions of Engineer-in-charge For following nominal sizes and piping material class. (Construction of trench, backfilling with sand shall be paid under separate item).

-

-

-

... More
Nominal Dia 1 Inch Piping Class J92A

550

783200

1424

... More
Nominal Dia 2 Inch Piping Class J92A

42

94878

2259

... More
Under Ground Sewer System - HDPE Pipe

-

-

-

... More
Supplying, laying and jointing of underground approved quality HDPE pipes to be used for soil and waste discharge or rain water application outside buildings confirming to IS: 14333 including all necessory fittings/ specials such as bends, Y junction, T junction (both single and double), plugs, coupler, adapter etc. including solvent welded jointing and testing as per manufacturers reommendations , including earthwork in excavation in all types of soil for pipe trenches, etc. including dewatering, shoring and strutting if necessary, dressing of sides, leveling, grading and ramming of bottoms, cutting the pipes to required lengths, lowering the pipes to proper grade and alignment, jointing, including connecting the pipes to manholes by using concrete manhole adapters and grouting the pipe body with manhole wall using cement mortar 1:2 (1cement : 2 sand), testing, draining of water and cleaning of pipe after testing, backfilling the trenches with select material from available excavated soil including re excavating the deposited soil excavated earlier breaking clods and laying in layers of 15cm compacted thickness , watering and compacting with mechanical means like vibro rammers etc. to 90% standard proctor density as per IS:2720 Part-VII, making good the surface, including cutting of roads wherever required and making good the same, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete for all depths as per drawings, specifications and instructions of Engineer-in-Charge. (Depth of excavation for pipe trench shall be upto 3.0m)

-

-

-

... More
(All material including cement supplied by Agency) Nominal Dia. 315 mm Pressure Rating(Kg/Cm2) 6

22

101376

4608

... More
(All material including cement supplied by Agency) Nominal Dia. 150 mm Pressure Rating(Kg/Cm2) 6

22

34848

1584

... More
(All material including cement supplied by contractor) Nominal Dia. 200 mm Pressure Rating(Kg/Cm2) 6

22

60192

2736

... More
(All material including cement supplied by contractor) Nominal Dia. 75 mm Pressure Rating(Kg/Cm2) 6

22

15048

684

... More
(All material including cement supplied by contractor) Nominal Dia. 250 mm Pressure Rating(Kg/Cm2) 6

22

69388

3154

... More
UNDERGROUND CI/ DI PIPING SYSTEM

-

-

-

... More
Supplying and laying CI Socket and Spigot Spun Pipes class conforming to IS:1536 with all necessary specials such as bends, tees, reducers, sockets, flanges, tail pieces, plugs etc., jointing by tyton or other similar joints with rubber gaskets in proper grade or alignment including cutting of pipes if required, earthwork in excavation, dismantling the existing road surface for pipe line trenches, in all types of soil except soft rock and hard rock for all depths including dewatering, shoring and strutting if necessary, dressing of sides and levelling, or grading and ramming of bottoms, connecting the pipes to manholes and jointing the pipe body to masonry/ concrete wall in cement mortar 1:2 (1 cement : 2 sand), watering, curing, hydrostatic testing for the complete pipe section, draining the water and cleaning the pipe line after testing, backfilling the trenches, etc. with selected materials from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying at all depths in layer of 15cm compacted thickness, watering and compacting with mechanical means like vibro rammers etc. to 90% Standard proctor density a per IS:2720 part VII, cutting of roads wherever required, making good the road surface etc. , disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and direction of Engineer-in-charge. For following Pipe size and Class

-

-

-

... More
Dia. 80 mm Pipe Class A

13

7020

540

... More
Supply, fabrication and Erection of piping (Above ground)

-

-

-

... More
Fire water spray/ sprinkler/ detection system G.I. PIPING A/G (Screwed)

-

-

-

... More
Supplying and laying ABOVE GROUND MILD STEEL GALVANISED PIPES for Fire water spray system/ sprinkler system/ detection system as per piping material specification including supply of reducing tees, fittings, elbows, nipples, Teflon tapes, white lead etc., cutting the pipes to required lengths, making threads, including laying of pipes on pipe rack, sleepers, T-supports, erection of piping on equipments, pumps etc. including joining of pipes and fittings with threaded/flanged connections, including installation of spray nozzles, Quartzoid bulb detectors, restriction orifice, flanges, break-up flanges, gaskets and bolts, hydrostatic testing of the piping including supply of necessary fittings etc. complete as per specifications, drawings and instructions of Engineer-in- charge.(Spray nozzles, restriction orifice, flanges and break-up flanges shall be paid separately under separate SOR/ shall be given as free issue to the contractor.) For following nominal sizes and piping material class.

-

-

-

... More
Dia. 1 Inch PMS J92A

224

358624

1601

... More
Dia. 2 Inch PMS J92A

4

10168

2542

... More
Drinking water G.I. PIPING (ABOVE GROUND)

-

-

-

... More
Supplying and laying ABOVE GROUND MILD STEEL GALVANISED PIPES for drinking water system as per piping material specification, including supply and installation of reducing tees, fittings, elbows, nipples, Teflon tapes, white lead etc., cutting the pipes to required lengths, making threads, including laying of pipes on pipe rack, sleepers, T-supports, erection of piping on technological structures etc. including joining of pipes and fittings with threaded/ flanged connections etc. hydrostatic testing of the piping including supply of necessary fittings etc. and pipe supports complete as per data sheets, specifications, drawings and instructions of Engineer- in-charge.(Pipe shall be insulated. S/I of insulation shall be under separate SOR)

-

-

-

... More
Dia. 2 Inch PMS J92A

4

8268

2067

... More
Dia. 3 Inch PMS J92A

4

11068

2767

... More
Dia. 4 Inch PMS J92A

9

33822

3758

... More
Supply and installation of valve assembly, flange assembly etc.

-

-

-

... More
Supply and installation of VALVE ASSEMBLY consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge.

-

-

-

... More
Gate valve assembly for following nominal sizes and piping material class

-

-

-

... More
Dia. 3 Inch PMS J92A

1

23976

23976

... More
Dia. 1 Inch PMS J92A

13

80236

6172

... More
Dia. 2 Inch PMS J92A

1

13353

13353

... More
Check valve assembly for following nominal sizes and piping material class

-

-

-

... More
Dia. 3 Inch PMS J92A

1

36069

36069

... More
Coating of field fabricated pipe specials

-

-

-

... More
Coating of field fabricated pipe specials like mitre bend, reducer etc. with Liquid epoxy coating (EP) as per DIN EN 10289, Class C, Type 3 including supply of coating material, inspection and testing for the coating as per specification.

-

-

-

... More
C.S MITRE BENDS-90 Degree; THK. = 10MM

-

-

-

... More
Nominal Dia. 150 mm

4

8100

2025

... More
Nominal Dia. 100 mm

4

5400

1350

... More
Nominal Dia. 600 mm

4

32400

8100

... More
Nominal Dia. 500 mm

4

27000

6750

... More
Nominal Dia. 400 mm

4

21600

5400

... More
Nominal Dia. 300 mm

4

16200

4050

... More
Nominal Dia. 200 mm

4

10800

2700

... More
C.S MITRE BENDS-45 Degree; THK. = 10MM

-

-

-

... More
Nominal Dia. 150 mm

4

6076

1519

... More
Nominal Dia. 100 mm

4

4052

1013

... More
Nominal Dia. 600 mm

4

24300

6075

... More
Nominal Dia. 500 mm

4

20252

5063

... More
Nominal Dia. 400 mm

4

16200

4050

... More
Nominal Dia. 300 mm

4

12152

3038

... More
Nominal Dia. 200 mm

4

8100

2025

... More
C.S CONC. REDUCERS; THK. = 10MM

-

-

-

... More
Nominal dia. 150 mm

4

4052

1013

... More
Nominal dia. 100 mm

4

2700

675

... More
Nominal dia. 600 mm

4

16200

4050

... More
Nominal dia. 500 mm

4

13500

3375

... More
Nominal dia. 400 mm

4

10800

2700

... More
Nominal dia. 300 mm

4

8100

2025

... More
Nominal dia. 200 mm

4

5400

1350

... More
FIRE FIGHTING EQUIPMENTS

-

-

-

... More
Installation of Deluge Valve Skid

-

-

-

... More
Installation, erection, testing and commissioning of Deluge Valve assembly Skid Actuated through wet detection/ air detection system including placing the skid at the dsignated location and fixing with anchoring bolts, connecting the water inlet and system piping, connecting detection network piping, fittings etc. complete for deluge valve skid assembly as per specification, drawings and directions of Engineer-in-Charge. (Deluge valve skid fitted with all instruments & piping/ valves shall be provided as free issue to the contractor.)

-

-

-

... More
Nominal Dia of Deluge Valve 4 Inch

3

151200

50400

... More
Nominal Dia of Deluge Valve 6 Inch

7

396900

56700

... More
Nominal Dia of Deluge Valve 8 Inch

4

302400

75600

... More
Nominal Dia of Deluge Valve 3 Inch

1

37800

37800

... More
Nominal Dia of Deluge Valve 2 Inch

1

25200

25200

... More
S/I Portable/ trolley mounted Extinguishers

-

-

-

... More
Installation of PORTABLE DCP (Dry Chemical Powder) Extinguisher including transporting the same to worksite from Owner's store, fixing in position including supply of all fixing material, labor etc. complete as per drawings, specification and directions of Engineer-in-Charge.

-

-

-

... More
Capacity 6 kg

4

1440

360

... More
Capacity 9 kg

4

2160

540

... More
Installing/Placing in position, trolley mounted DCP (Dry Chemical Powder) portable extinguisher including transporting the same to worksite from Owner's store, labor etc. complete as per drawings, specification and directions of Engineer-in-Charge.

-

-

-

... More
Capacity 50 kg

2

3600

1800

... More
Capacity 75 kg

1

2520

2520

... More
Installation of PORTABLE CO2 (Carbon dioxide) extinguisher including transporting the same to worksite from Owner's store, fixing in position including supply of all fixing material, labor etc. complete as per drawings, specification and directions of Engineer-in-Charge.

-

-

-

... More
Capacity 4.5 kg

4

1440

360

... More
Installation of firefighting equipment including transporting the equipment from Owner's store to work site, fixing of nuts, bolts, washers, gaskets needed for fixing the equipment with matching flange, welding etc. complete as per drawings, specifications and direction of Engineer-in- Charge. (All fire fighting equipment's and accessories shall be supplied by the owner)

-

-

-

... More
Installation of Type-II Hose Box Chamber including all items inside the chamber, fixing in position with anchor bolts/ PCC Block in foundation, including all civil works and supply of all materials including cement etc. (hose box and inside accessories supplied free of cost by owner)

95

82080

864

... More
Remote operated long range water/ water cum foam monitor on technological structure/ pipe rack/ independent tower etc.

6

108000

18000

... More
Stand Post type fire hydrant ( Double outlet)

130

140400

1080

... More
Long range water/ water cum foam monitor

65

702000

10800

... More
First Aid hose reel (Wall Mounted)

20

14400

720

... More
First Aid hose reel (Floor Mounted)

2

1440

720

... More
Double headed landing valve

20

28800

1440

... More
Repairing of 3LPE coating

-

-

-

... More
Repairing of the 3LPE coating of the pipe by Coating of pipe and fittings with Liquid epoxy coating (EP) as per DIN EN 10289, Class C, Type 3 including supply of coating material, inspection and testing for the coating as per specification and directions of Engineer-in-Charge.

450

1093500

2430

... More
CONCRETE PAVEMENTS

-

-

-

... More
Providing and laying Reinforced Cement Concrete with 20mm and down size graded crushed stone aggregates in flooring, pavements etc. including leaving pockets, if necessary, making recess/drains, laying in alternate panels, etc. for all depths including shuttering, tamping, curing, etc. as specified in any shape, thickness, position and finishing the top surface smooth etc. all complete as per drawings, specifications and directions of Engineer-in-Charge.

-

-

-

... More
For RCC of M-30 grade concrete (all materials including cement but excluding cost of providing & fixing reinforcement and joint sealing shall be supplied by the contractor).

45

254745

5661

... More
Providing 20mm wide Expansion Joints in pavement slabs as per std. No.7-65-0404 including cleaning the joints of all loose material, filling with 20mm thick impregnated fibre boards for the full depth of slab except for 25mm depth from top and sealing the top 25mm with approved Silicone Sealant as per ASTM 5893 including providing primer as per IRC-57 etc. all complete as per drawings, specifications and directions of Engineer-in-Charge.

-

-

-

... More
For type-I pavement (Upto and inclusive of thickness of 200 mm). (Including providing and laying MS dowel bar, painting as required, GI pipe and cap and cotton waste).

13

7956

612

... More
For type-II pavement (Upto and inclusive of thickness of 150 mm)

25

3450

138

... More
For type-III pavement (Upto and inclusive of thickness of 100 mm).

4

460

115

... More
For thickened pavement (Upto and inclusive of thickness of 300 mm).

4

672

168

... More
Providing joints in pavements and around foundations as per std. no.7-65-404 including cleaning the joints of all loose materials and sealing with Silicone Sealant as per ASTM 5893 including providing primer as per IRC-57 as required etc. complete as per drawings, specifications and directions of Engineer-in-Charge for;

-

-

-

... More
Construction joints 20mm wide x 25mm deep.

10

1150

115

... More
Sealing joint around pedestal and column etc. 20mm wide x 200 mm deep including filling with 20mm thick impregnated fire board for the full depth of slab except for 25mm depth from top and sealing the top 25mm with approved Silicone Sealant as per ASTM 5893 including providing primer as per IRC-57.

4

460

115

... More
Sealing joint around pedestal and column etc. 20mm wide x 150 mm deep including filling with 20mm thick impregnated fire board for the full depth of slab except for 25mm depth from top and sealing the top 25mm with approved Silicone Sealant as per ASTM 5893 including providing primer as per IRC-57.

4

460

115

... More
Sealing joint around pedestal and column etc. 20mm wide x 100 mm deep including filling with 20mm thick impregnated fire board for the full depth of slab except for 25mm depth from top and sealing the top 25mm with approved Silicone Sealant as per ASTM 5893 including providing primer as per IRC-57.

4

460

115

... More
Sealing joint around pedestal and column etc. 20mm wide x 300 mm deep including filling with 20mm thick impregnated fire board for the full depth of slab except for 25mm depth from top and sealing the top 25mm with approved Silicone Sealant as per ASTM 5893 including providing primer as per IRC-57.

4

460

115

... More
Supplying and laying of 150 micron thick HM HDPE (Grade-I) FILM lining conforming to IS 10889 below concrete pavements, Hard stand, at any other place etc. including royalties, taxes, handling, transportation, unloading, storage, joining etc. all complete as per drawings, manufacturer's specifications and directions of Engineer-in-charge.

300

34500

115

... More
Supply of all materials and Construction of DRY LEAN CEMENT CONCRETE SUB-BASE (7 days compressive strength of 10.0 MPa) with 26.5 mm and down size aggregate including ordinary portland cement 43 Grade, water and approved additives on a prepared sub-grade, mixed in batching plant, transported to site, for all leads & lifts, laid, compacted, finished and cured etc. complete as per IRC:SP:49 (Guidelines for the use of Dry Lean Concrete as Sub- Base), drawings, standards, specifications and directions of Engineer-in-charge.

35

85680

2448

... More
Supply of Manpower : Agency to provide & mobilise following manpower as per instructions of Engineer in-charge for delivering exclusive service to B AND R . However, 2 weeks' notice shall be given for mobilisation and 1 day notice shall be given for demobilisation. Note that quoted rate of manpower deployment shall be inclusive of cost towards required PPEs, facilities ecessary for functioning at site and complience of applicable Statutory obligation e.g P.F. & ESI etc. (1 Man-Month should be considered as 30 man-days).

-

-

-

... More
ENGINEER :

-

-

-

... More
PLANNING

14

630000

45000

... More
CIVIL / MECHNICAL

84

3780000

45000

14

415800

29700

... More
SAFETY

-

-

-

... More
LEAD SAFETY OFFICER

14

756000

54000

... More
SUPERVISOR/STEWART

56

1058400

18900

... More
SUPERVISOR

-

-

-

... More
PLANNING

14

415800

29700

28

831600

29700

... More
CIVIL / MECHNICAL

140

4158000

29700

... More
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.