Oil And Natural Gas Corporation Limited Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 85,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ONGC_209835_1Tender No
EY15C24013Tender Authority
Oil And Natural Gas Corporation Limited ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
providing and erecting Approved make standard Draw out type 3 Pole Air circuit breaker. Having following kA breaking capacity with ICU=ICS=ICW (1 sec)Vsr=690 v, Ui=1kv ,impulse voltage=12 kv with following type of relay and accessories. (1) Manual Draw out type (MDO) with following type of relay system
(B) with microprocessor Release with over load, short circuit, earth fault protection (L.S.I.G.) and metering display in modular design with LED display and Test Trip button facility, CTs and auxiliary contacts, of following current ratings (viii) 4000 Amp 80kA Cat III ( SS CTF)
1
359350
359350
providing and erecting Approved make standard Draw out type 3 Pole Air circuit breaker. Having following kA breaking capacity with ICU=ICS=ICW (1 sec)Vsr=690 v, Ui=1kv ,impulse voltage=12 kv with following type of relay and accessories. (1) Manual Draw out type (MDO) type with following type of relay system
(B) with microprocessor Release with over load, short circuit, earth fault protection (L.S.I.G.) and metering display in modular design with LED display and Test Trip button facility, CTs and auxiliary contacts, of following current ratings (v) 2000 Amp 50kA Cat III ( SS CTF )
1
204540
204540
providing and erecting Approved make standard Draw out type 3 Pole Air circuit breaker. Having following kA breaking capacity with ICU=ICS=ICW (1 sec)Vsr=690 v, Ui=1kv ,impulse voltage=12 kv with following type of relay and accessories.(1) Manual Draw out type (MDO) type with following type of relay system
(B) with microprocessor Release with over load, short circuit, earth fault protection (L.S.I.G.) and metering display in modular design with LED display and Test Trip button facility, CTs and auxiliary contacts, of following current ratings vi) 2500 Amp 60kA Cat III ( MHN CTF)
1
233140
233140
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 K.A. and above at 415 V having normal current rating 800A.with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S.housing.( MHN CTF)
1
35905
35905
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 K.A. and above at 415 V having normal current rating up to 630A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing , Cat-III
9
296235
32915
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 KA and above at 415 V having Normal current rating 400A. with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. With all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. ,Cat-III
4
117900
29475
Providing and erecting following additional parts for panel mounting MCCBs (B)Extended operating rotary handle with pad lock with three position trip,off,on suitable for 400A to 800 A panel mounting cat-III
14
21420
1530
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit breaker having CT ratio & MCCB rating as following along with shunt trip 220V AC. with all internal connections & complete erected in existing M.S.housing. suitable for 400 A , CT Ratio 1/400
4
25300
6325
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit breaker having CT ratio & MCCB rating as following along with shunt trip 220V AC. with all internal connections & complete erected in existing M.S.housing suitable for 630 A to 4000 A, CT Ratio 1/800
13
91975
7075
Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 digits LED display, 0 to 750 AC Volts range erected on existing panel board with all connection, wiring etc .with manufacturers calibration certificate.
2
2980
1490
Supplying and erecting approved make panel mounting type Digital Ammeter having 3 digits LED display, external CT operated, calibrated for 0 to 1000 Amps suitable to operate on 500 Volt AC , erected on existing panel board with all connection, wiring etc .with manufacturers calibration certificate.
2
3640
1820
Supplying and erecting Ammeter / Voltmeter selector switch for 3 phase AC Supply 500 V on existing panel board with necessary connections.
4
1480
370
Supplying and erecting approved make suitable panel indicator LED type lamp, lens cover, complete erected with necessary connections.
12
600
50
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 6-32 A Cat -III
20
7000
350
Supplying & erecting Chemical Earthing- with earth pit & chember of minimum bore dia.150mm size approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia of 50mm Inner pipe dia of 25 mm connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for Panel Installation Length of pipe - 3 Mtr
Back filling compound - 1 No Bag of 15 Kg.
4
24230
6057.56
Providing , erecting & connecting GI strip 38x6 mm/ 25x6 mm with suitable SS nut bolts and washer - as per IS 3043. zincGalvanizing thickness 80 micron in strip.
80
17220
215.26
Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for size of cables.(C) 3.5 core 240/300 Sq. mm
35
40391
1154.03
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. One wire 4.00 sq. mm
40
1600
40
Control Transformer copper wound 1 KVA ,415/220 Volts
4
28880
7220
Installation & commissioning charges for panel [Size: 4 mtr.x 2.2 mtr. & 1mtr depth (approx)] including transportation of panel, placement of panel with C -chanels , angles arrangement , cable connections with lugging in new panel board & new transformer , disconnection of old transformer/ making of trench if reqd etc. LS charges
2
400000
200000