Oil And Natural Gas Corporation Limited Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Oil And Natural Gas Corporation Limited - ONGC Tender

Works
Electrical and Electronics
Eprocure
Opening Date30 Sep 2024
Closing Date22 Oct 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
providing and erecting Approved make standard Draw out type 3 Pole Air circuit breaker. Having following kA breaking capacity with ICU=ICS=ICW (1 sec)Vsr=690 v, Ui=1kv ,impulse voltage=12 kv with following type of relay and accessories. (1) Manual Draw out type (MDO) with following type of relay system (B) with microprocessor Release with over load, short circuit, earth fault protection (L.S.I.G.) and metering display in modular design with LED display and Test Trip button facility, CTs and auxiliary contacts, of following current ratings (viii) 4000 Amp 80kA Cat III ( SS CTF)

1

359350

359350

... More
providing and erecting Approved make standard Draw out type 3 Pole Air circuit breaker. Having following kA breaking capacity with ICU=ICS=ICW (1 sec)Vsr=690 v, Ui=1kv ,impulse voltage=12 kv with following type of relay and accessories. (1) Manual Draw out type (MDO) type with following type of relay system (B) with microprocessor Release with over load, short circuit, earth fault protection (L.S.I.G.) and metering display in modular design with LED display and Test Trip button facility, CTs and auxiliary contacts, of following current ratings (v) 2000 Amp 50kA Cat III ( SS CTF )

1

204540

204540

... More
providing and erecting Approved make standard Draw out type 3 Pole Air circuit breaker. Having following kA breaking capacity with ICU=ICS=ICW (1 sec)Vsr=690 v, Ui=1kv ,impulse voltage=12 kv with following type of relay and accessories.(1) Manual Draw out type (MDO) type with following type of relay system (B) with microprocessor Release with over load, short circuit, earth fault protection (L.S.I.G.) and metering display in modular design with LED display and Test Trip button facility, CTs and auxiliary contacts, of following current ratings vi) 2500 Amp 60kA Cat III ( MHN CTF)

1

233140

233140

... More
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 K.A. and above at 415 V having normal current rating 800A.with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S.housing.( MHN CTF)

1

35905

35905

... More
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 K.A. and above at 415 V having normal current rating up to 630A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing , Cat-III

9

296235

32915

... More
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 KA and above at 415 V having Normal current rating 400A. with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. With all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. ,Cat-III

4

117900

29475

... More
Providing and erecting following additional parts for panel mounting MCCBs (B)Extended operating rotary handle with pad lock with three position trip,off,on suitable for 400A to 800 A panel mounting cat-III

14

21420

1530

... More
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit breaker having CT ratio & MCCB rating as following along with shunt trip 220V AC. with all internal connections & complete erected in existing M.S.housing. suitable for 400 A , CT Ratio 1/400

4

25300

6325

... More
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit breaker having CT ratio & MCCB rating as following along with shunt trip 220V AC. with all internal connections & complete erected in existing M.S.housing suitable for 630 A to 4000 A, CT Ratio 1/800

13

91975

7075

... More
Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 digits LED display, 0 to 750 AC Volts range erected on existing panel board with all connection, wiring etc .with manufacturers calibration certificate.

2

2980

1490

... More
Supplying and erecting approved make panel mounting type Digital Ammeter having 3 digits LED display, external CT operated, calibrated for 0 to 1000 Amps suitable to operate on 500 Volt AC , erected on existing panel board with all connection, wiring etc .with manufacturers calibration certificate.

2

3640

1820

... More
Supplying and erecting Ammeter / Voltmeter selector switch for 3 phase AC Supply 500 V on existing panel board with necessary connections.

4

1480

370

... More
Supplying and erecting approved make suitable panel indicator LED type lamp, lens cover, complete erected with necessary connections.

12

600

50

... More
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 6-32 A Cat -III

20

7000

350

... More
Supplying & erecting Chemical Earthing- with earth pit & chember of minimum bore dia.150mm size approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia of 50mm Inner pipe dia of 25 mm connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for Panel Installation Length of pipe - 3 Mtr Back filling compound - 1 No Bag of 15 Kg.

4

24230

6057.56

... More
Providing , erecting & connecting GI strip 38x6 mm/ 25x6 mm with suitable SS nut bolts and washer - as per IS 3043. zincGalvanizing thickness 80 micron in strip.

80

17220

215.26

... More
Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for size of cables.(C) 3.5 core 240/300 Sq. mm

35

40391

1154.03

... More
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. One wire 4.00 sq. mm

40

1600

40

... More
Control Transformer copper wound 1 KVA ,415/220 Volts

4

28880

7220

... More
Installation & commissioning charges for panel [Size: 4 mtr.x 2.2 mtr. & 1mtr depth (approx)] including transportation of panel, placement of panel with C -chanels , angles arrangement , cable connections with lugging in new panel board & new transformer , disconnection of old transformer/ making of trench if reqd etc. LS charges

2

400000

200000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.