National High Speed Rail Corporation Limited Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

National High Speed Rail Corporation Limited - NHSRCL Tender

Works
Eprocure
Opening Date5 Oct 2020
Closing Date26 Oct 2020
Tender Amount₹ 9,05,62,897 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ of Signal and Telecommunication Utility Shifting Work from Vishwamitri to Pandya Bridge in Connection with Construction of MAHSR
Signal and Telecommunication Utility Shifting Work from Vishwamitri to Pandya Bridge in Connection with Construction of MAHSR
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
PVC Insulated, Unscreened Armoured, Underground Power Cable Size 2 Core X 25 Sq.mm Aluminium Conductor, RDSO Specn.No.IRS-S-63/2014 No.IS:1554 (PART I)

5.5

-

87110.4

... More
ARA Terminal blocks with links made of PBT Spec No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4.

150

-

72.6

... More
Disconnect Terminal Block, Screw less type as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments., 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3)

7500

-

58.08

... More
Supply of End plate for above item (I) 2.5mm/0.091 in thick as per site requirement.

1500

-

10.89

... More
Supply of End Stopper for above item (I) 10mm/0.0394 in width as per site requirement.

750

-

10.89

... More
Supply of Carrier Rails for above item 35mmx7.5mm,1mm/0.039 in thickness un-slotted type as per site requirement

150

-

113.74

... More
Markers strip for above item

7500

-

16.94

... More
Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.

7650

-

13.31

... More
Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50M and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker.

250

-

433.78

... More
Workstation with specification as "Intel Core i7 9700 16 GB/ 1000 GB HDD/ Windows 10 Professional. Make Hp/DELL or Similar

2

-

80999

... More
Apparatus Case Single NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A, fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377. Note: This item includes the supply & fixing of 2 Nos E Type Lock fitted on both doors, along with two Keys.

23

-

15889.72

... More
Apparatus Case half NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A fitted two nos E Type lock of (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377. Note: This item includes the supply & fixing of 2 Nos E Type Lock fitted on both doors, along with two Keys.

22

-

10035.74

... More
Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (20KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008.

45

-

9413.33

... More
Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer dia,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified

80

-

1898.53

... More
Half Round RCC pipes & collars of 300 mm outer dia & 250 mm internal dia (2-meter-long) along with collars as per IS No. 458/2003 of NP type

1700

-

721.16

... More
Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied

45

-

4941.64

... More
Excavation of cable trench as per cable route plan,1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtrs wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m

1500

-

289.59

... More
Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable

500

-

1247.51

... More
Supply of HDPE pipe as per IS 484-1995 and size 315mm dia. Of make Jin/Equivalent make. It includes loading, unloading, transportation etc.

1950

-

3638.75

... More
Laying of 315mm Dia HDPE pipe underground at the depth of atleast 2.50 meter from ground (the top of the pipe should be at 2.05 meter from ground level) using HDD machine including all related works i.e drive pit for machine, receiving pit for the pipe, required excavation on both sides of road, back filling, levelling etc. as per direction and instruction of Railway Engineer. Laying of signal Cable inside 315mm dia HDPE pipe by properly taking out the cable from drum without damaging the cable in proper level and alignment. Supply of HDPE pipe is taken separately.

1950

-

5791.25

... More
Laying of signal cable inside 315mm dia HDPE pipe by peroperly taking out the cable from drum without damaging the cable in proper level and alignment (cable in drum will be provided by railway free of cost)

58500

-

51.25

... More
Multi Function Printer HP 34 inch T-830 Model or similar

1

-

179360

... More
Trunking and capping to Part 7 & 17 respectively to Drg.no. CSTE/6224A

200

-

428.34

... More
Laying of capping on cable laid in trunking / directly of cables

200

-

10.89

... More
Placing of DWC/RCC/GI pipes along with collars in trenches at places of track and road crossings, platform cuttings etc.

480

-

31.24

... More
Laying of half round RCC pipe after laying the cables in the trenches. (Cable laying is covered separately)

3400

-

22.83

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.

100000

-

9.61

... More
Termination of cable cores on ARA terminal/fuse blocks, 8 way terminals block/ Screw less connectors in the apparatus Cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Railway Engineer at site. This item includes dressing of Cable, making wiring tree etc.

7650

-

2.42

... More
Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. Single Case as per Drg No SK 748 or CSTE/5074

23

-

7324.13

... More
Half Case as per Drg No SK 747or CSTE/5074 or SS Location

22

-

5591.41

... More
Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. Single Case

23

-

1104.73

... More
Half Case

22

-

672.76

... More
Fabrication and fixing of phenolic laminated sheet of size 10mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. Single Case

23

-

2492.6

... More
Half Case

22

-

727.21

... More
Installation of Maintenance free Earth Electrode for Maintenance free earth spec of RDSO/SPN/197/2008

45

-

1512.81

... More
Preparation of cable route plan, cable coreage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD in A3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with CD & 4 sets of final approved drawings. This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge. For small/medium yards

2

-

21329.88

... More
Tools as per Annexure

1

-

38713.18

... More
Digital Multimeter of Fluke 287 Industrial, True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 second or Superior make

1

-

46828.21

... More
Cable Route Locator/Tracer set suitable for detecting under ground armoured optic fiber cable and signalling cable with LCD graphic display active/ passive modes and depth range 4M-10M. The set shall consist of the following : 1. Receiver seek Tech line locator/ cable avoidance tool-01 no 2. Transmitter/ signal generator complete with earth stake & connection leads- 01 no 3. Inductive signal clamp -01 no Model no 8100 PDLG of M/s Radio Detection (UK) or similar. Inspection by RDSO

1

-

731600

... More
Cable termination racks as per Drg. no. CSTE 5004, 5005, 5006 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8-way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated.

2

-

24168.54

... More
Installation of Cable Termination Racks Assembly complete including wall supports, scaffolding, 8 way/ARA terminals /Screw less connectors, Tag blocks & other necessary accessories etc. The work shall be done as per approved plan, extant practice on WR & the instruction of Rly engineer at site.

2

-

9235.93

... More
PVC insulated Railway Signaling Indoor Single core wire conforming to IRS 76/89 (Amd3) or latest. Note: - Wire Colours shall be decided by engineer - in - Charge. Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3).

2.25

-

5581.73

... More
Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm. ( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89.

0.5

-

41286.41

... More
Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 + 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89.

0.5

-

132848.32

... More
Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89.

0.25

-

151277.83

... More
Program switches, snap action, base mounting type along with acrylic cover and mounting bracket, 25A, 6 pole, 3 position Siemens make or Similar.

9

-

6602.97

... More
Termination of outdoor cables, main cables laid in location boxes, Cable termination rack etc at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site. This item includes dressing of Cable, making wiring tree etc.

1500

-

2.42

... More
Fire Extinguisher CO2 type (capacity 5 kg.)

8

-

7057.93

... More
Digital Current clamp meter to measure current leaks [perasitic draws down to 1mA and electric loads from 1 mA to 100 Amp AC/DC and voltages from 0 to 600 V AC/DC, small jaw size to measure current in signalling circuits, 4 digit display. Make- Fluke/GTC/KEW or superior with better specificationas mentioned, with all accessories like test lead, batteries and carrying case, sample may be got approved from consignee before supply.

1

-

14299.2

... More
Supply of Megger 100 Volts as per specification.

1

-

1429

... More
Supply of Megger 500 Volts as per specification.

1

-

1429

... More
Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6 . Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).

15

-

3857.48

... More
Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.

30

-

2116.29

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. Full Case.

23

-

127.05

... More
Half Case

22

-

87.12

... More
Track relay QTA2, AC immunized, 9 Ohm, 2F.1B, along with plug board, retaining clip and connectors conforming to BRS:939A, BRS:966, IRS:S34 & IRS:S23.

20

-

5372.4

... More
Choke Coil for Single Rail Track Circuit on 25 KV 50 Hz AC Electrified Section as per Spec No IRS S 65/1983 with latest amendments.

20

-

1679.48

... More
Adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv) with latest amendments (with Phenolic moulded base).

20

-

878.46

... More
Track Lead Junction Boxes as per C.Rly Drg. No.RST 11509 made from fiber glass along with terminal blocks.

40

-

998.25

... More
Installation of DC track circuits covering points zones also. The item includes provision of continuity bonds of seven strand PVC jacketed wire/ GI wire 8 SWG on rail joints after drilling bond-hole of 7.0/7.1/7.2mm dia (double bond with sleeves and rail clips are to be provided at each rail joint), insertion of insulated block joint, fixing of Track lead Junction box on MS angle two numbers of size 40X40X5 mm 1200 mm length for track feed/ jumper / track relay ends of track CCTs (as per double TLJB arrangements) and also for fixing jumper cables as per insulation diagram WR Drg No. CSTE/6055 and standard practice, making rail connections through suitable insulated sleeves from Track lead Junction box at TF, jumper & TR end with seven strand PVC jacketed wire /GI wire 8 SWG , rail clips for fixing bond wire on the TLJB as per standard practice, termination of tail cables on bootleg terminals etc. TF/TR wiring shall be fixed on the suitable arrangement on PRC sleepers with the help of Hooks. Hooks shall be provided on PRC sleepers with the help of suitable steel bracket. This item also includes fixing & supply of channel pins etc. The item also includes supply of MS angles / trestles, GI wire 8 SWG / seven strand PVC jacketed wire, hooks, rail clips etc. (Supply of insulation material for block joint & Boot leg is covered in Schedule separately or will be supplied by Railways).

10

-

7373.74

... More
Low maintenance Lead acid secondary cell 2V/80 AH (Track feed Battery), shelf mounting type conforming to IRS:S- 88/2004 or latest (uncharged)

50

-

2198.57

... More
Medium Class G.I. Pipes to IS : 1239 (Pt.I)-2004 or latest ; 100mm dia. ( int. dia) 3.65 mm+/- 10% thick with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes.

500

-

603.2

... More
Charging of Lead Acid Batteries with contractors own battery grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of W.Rly & instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge.2V 80AH

50

-

394.46

... More
Track feed battery chargers, 110V AC input, 2 to 6 V DC Output; as per Specn.No.IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery.

20

-

3277.89

... More
Digging of trench 1.2 M deep from rail flange/ road level and, 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe coverd separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No.CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed.

30

-

291.61

... More
Dismantling / Releasing of existing Signaling Gears. One Signalling gear will be all parts of one signal (consisting of CLS unit, Signal post along with base) or lever frame (5 levers set), or one point (consisting of all parts of a mechanical point, point machine, ground connections etc.) or one track circuits (consisting of battery box & other parts of DC Track circuit / AFTC /DAC) or one Apparatus case etc. This includes the cost of transportation of release materials to store depot or as decided by consignee in charge. This work to be done by contactors with his own vehicle and labour (Rate to be consider when total gear to be dismantled at a station is more than 10)

30

-

1027.29

... More
Provision for Hiring of Vehicle for 24hrs for a period of 12 months.

12

-

45001.8

... More
Shifting of Axle counter Sk30h Double Rail Contact (Tx-Coil) With 8 Meter Integral Cable Eldyne or similar Make Multi Section Digital Axle Counter As Per Rdso Specn.Rdso/Spn/176/2013 Version 3

6

-

72700

... More
Sk30h Double Rail Contact (Rx-Coil) With 8 Meter Integral Cable Eldyne or similar Make Multi Section Digital Axle Counter As Per Rdso Specn.Rdso/Spn/176/2013 Version 3

6

-

72700

... More
SK 30H Double Rail contact with 5.5 mtr. Tx Coil (Tx1 & Tx2) for Axle counter Eldyne or similar Make

6

-

67300

... More
SK 30H Double Rail contact with 5.5 mtr. Rx coil(Rx1 & Rx2) for Axle counter Eldyne or similar Make

6

-

67300

... More
Analog card (AzLS) for Axle counter Eldyne or similar Make

5

-

75075

... More
Digital card (AzLS) for Axle counter Eldyne or similar Make

5

-

145255

... More
Track side Electronics Unit (EAK‐AzLM) for Axle Counter Eldyne or similar make

5

-

289335.38

... More
Parallel card for multi section digital axle counter (AzLM) Eldyne or similar make

5

-

76551.36

... More
Serial card for multi section digital axle counter (AzLM) Eldyne or similar make

5

-

76551.36

... More
CPU Card for MSDAC Eldyne or similar make

5

-

395508

... More
PDCU card for MSDAC Eldyne or similar make

5

-

26439.68

... More
Telecom PART

-

-

-

... More
Supply of Underground Railway Jelly Filled Telecom Quad Cable for Railway Signalling and Telecom Installations as aer IRS T C:30/2005 Ver.1 with Amdt -05 Or Latest Size 6 Quad Cable 0.9mm Dia.

9

-

244850

... More
Supply of Polythene insulated polythene sheathed jelly filled (PIJF) cable as per RDSO specification IRS:TC-41/97 AMD. 03 or latest 50 pair x 0.63 mm dia

5

-

378780

... More
Supply of Underground 20 Pair PIJF Cable 0.5 mm Dia as per Specification No.IRS:TC-41/97 With Amndt No - 03 Or Latest.

2

-

141600

... More
Supply of Heat Shrinkable jointing kit with 2T transformer suitable for 6 quad cable and PIJF cable as per IRS: TC 77/2012 (Rev.3.0) with Amdt.-1,2&3 latest

15

-

3757.08

... More
Thermo Shrink Jointing Kit For Jointing Underground PIJF Cable as per RDSO Specn RDSO/SPN/TC/57/2015 (Rev.1) Amdt-1 Or Latest (TSF-2)

4

-

1003

... More
Thermo Shrink Jointing Kit for Jointing Underground PIJF Cable As per RDSO Specn RDSO/SPN/TC/57/2015 (Rev.1) Amdt-1 or Latest (TSF-3)

10

-

1398.3

... More
Supply of 50 Pair Outdoor Cable Termination Box with Brass Washers having tight locking arrangement

4

-

4867.5

... More
Supply of Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (20KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008

2

-

9413.33

... More
Supply of Half Round RCC pipes & collars of 150 mm internal dia (2 meter long) along with collars as per IS No. 458/2003 of NP type

2000

-

352.07

... More
Supply of Double Wall Corrugated (DWC) pipe with associated collars etc. as per specification no. IS 14390 part I & II or latest anti- rodent & anti-oxidant & non-flame propogating type in 6 meters straight length and of size 120 mm outer dia. & 103.55 mm inner dia. (the manufacturer, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). The required coupling arrangement should also be supplied as per RDSO/SPN/204/2011 Ver.1.1 or latest. 1) Suitable snapfit coupler with rubber O Ring 2) Spacers 3) Tees 4) Bend 5) End cap

30

-

1898.53

... More
Supply of Medium Class G.I. Pipes to IS : 1239 (Pt.I)-2004 or latest ; 100mm dia. ( int. dia) 3.65 mm+/- 10% thick with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes.

90

-

603.2

... More
Installation of Maintenance free Earth Electrode for Maintenance free earth spec of RDSO/SPN/197/2008

2

-

1512.81

... More
Excavation of cable trench as per cable route plan,1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtrs wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.

1500

-

289.59

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.

16000

-

9.61

... More
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.

90

-

206.68

... More
Jointing of 4 / 6 quad /Signaling cable with Heat Shrinkable straight through Jointing Kit. All the material required for the work are to be arrange by contractor himself at his own cost except Thermo shrinkable Joint Kit . After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost.

25

-

1222.03

... More
Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50m and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker

90

-

433.78

... More
Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. this include insertion of different dia DWC pipe/ GI pipes coupling etc. as per direction of Engineer In charge.

100

-

1247.51

... More
Laying of half round RCC pipe after laying the cables in the trenches. (Cable laying is covered separately)

4000

-

22.83

... More
Placing of DWC/RCC/GI pipes along with collars in trenches at places of track and road crossings, platform cuttings etc.

180

-

31.24

... More
Fixing of all types of Cable Termination box andtermination of cable. This include armour earthing also.

4

-

293.08

... More
Supply, Fabrication & Errection of Emergency post assembly complete with 6 Pin Socket Box and its wiring as directed by Engineer In charge. Complete work will be done by contractor with excavation, if required. Emergency plug & socket should be RDSO Spcn. No. IRS/TC/42/87or latest & each socket should have inbuilt universal lock with key. this includes erection of whole assembly it's foundation by brick, masonary and painting of whole assembly including EC Socket box. Note:- One sample of fabricated post to be got approved from Railway Engineer in charge before bulk supply.

8

-

2187.49



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.