Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Housekeeping Services
Eprocure
Opening Date29 Jan 2020
Closing Date17 Feb 2020
Tender Amount₹ 6,41,111 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for brick work with sub class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 (for manhole) complete all as specified and directed by Engr-in-charge.

8

-

-

... More
450 mm bore of pipe SGSW/RCC drain pipe

1000

-

-

... More
Taking down cement plaster on brick, stone or concrete surface including racking out joints hacking for key scrubbing down with water to receive plaster including removal of rubbish, etc. complete all as specified and directed by Engr-in-charge.

80

-

-

... More
Removing excavated materials to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m from starting point.

70

-

-

... More
150mm bore of pipe SGSW/RCC drain pipe

1500

-

-

... More
Preparation of new plastered surface and applying three coats of white wash etc. complete all as specified and directed by Engr-in-charge.

80

-

-

... More
M&L for RCC pipes Class NP-2 of size 450mm internal dia, laid in trenches and jointed with collar/push joint complete all as specified and directed by Engr-in-charge.

-

-

-

... More
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exc. 25 cm depth as in any type of soil complete all as specified and directed by Engr-in-charge.

100

-

-

... More
M&L for providing factory made precast reinforced cement concrete manhole cover in cement concrete 1:2:4 type B-1 (using 20/15 mm graded stone aggregates) surface area n.exc 0.80 sqm complete all as specified and directed.as in repairs. NOTE : Quoted rates deemed be inclusive of reinforcement bars.

90

-

-

... More
Cleaning of Sewage manholes etc. by removing accumulated sludge, silt and waste material including sludge water and removing to a distance out side of MOD land and depositing at a approved yard fixed by Defence/Local state authority with closed sewage containers by manually (Pumping/ removal of floating materials as required and work in foul places is included).The rates are deemed to be included for necessary safety equipments , tools and plants, complete all as specified and directed by Engr-in-charge. NOTE : (i) Measurement will be as measured at site i,e volume as calculated with actual dimensions before cleaning and after cleaning of sludge/solid materials as available (Pumping/ removal of floating materials as required and work in foul places is included).The rates are deemed to be included for necessary safety equipments, tools and plants, complete all as specified and directed by Engr-in-charge. (ii) Rates quoted be deemed inclusive of closing drain/pipe/manholes with gunny bags etc. to stop incoming sewage during cleaning.

-

-

-

... More
Taking down/Demolition of existing broken manholes cover of different size

90

-

-

... More
100 mm bore SGSW/RCC drain pipe

500

-

-

... More
All as per item No. 5 here-in-before but depth exc 3.00 m but n.exc 4.50 M in hard/dense soil

50

-

-

... More
Cleaning of PVC/CI sewer/sludge pipe from floor trap,PVC bend to gully trap/manholes in ground floor.

20

-

-

... More
Demolition and breaking up any sewage drain pipe not exceeding 150mm bore dia set in cement mortar including haunching complete all as specified and directed by Engr-in-charge.

50

-

-

... More
M&L for RCC pipes Class NP-2 of size 300mm internal dia, laid in trenches and jointed with collar/push joint complete all as specified and directed by Engr-in-charge.

-

-

-

... More
Depth of manholes up to 1.50 Mtr

100

-

-

... More
200/300 mm bore of pipe SGSW/RCC drain pipe

2000

-

-

... More
M&L for cement concrete bedding and haunching against the sides of pipes after they are laid to 300mm bore drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) laid to falls including packing under, and tested, complete all as specified and directed by Engr-in-charge. NOTE :- Pipe shall be measured and paid separately)

-

-

-

... More
S&F in repairs PVC (SWR) bend any radius, 75 mm dia with access door.

12

-

-

... More
Depth of manholes exc 1.50 mtr and n.exc 3.00 mtr

300

-

-

... More
450 mm bore of pipe SGSW/RCC drain pipe

200

-

-

... More
150mm bore of pipe SGSW/RCC drain pipe

500

-

-

... More
200/300 mm bore of pipe SGSW/RCC drain pipe

500

-

-

... More
Excavation in trenches n.exc 1.5 m wide & n.exc 1.5 m depth for foundations, sewage lines etc. and n.exc 10 Sqm on plan for manholes and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.

20

-

-

... More
Depth of manholes exc 3.00 mtr and n.exc 4.50 mtr

300

-

-

... More
Demolition of brick work/stone masonry built in cement mortar of any description

8

-

-

... More
S & Fixed in repairs PVC (SWR) pipes 75mm bore confirming to IS-13592-1992 type 'B' single socketed, in any length with rubber ring joints fixed to walls with PVC clamp complete all as specified and directed by Engr-in-charge.

20

-

-

... More
M&L for cement concrete bed to drain pipes, 150mm dia including forming cradles in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) complete all as specified and directed by Engr-in-charge. NOTE :- Pipe shall be measured and paid separately) as in repairs.

-

-

-

... More
Cleaning of Septic tank, Soakage well, Filter Chamber, etc. by removing accumulated sludge, silt and waste materials including sludge water and removing to a distance out of MOD land and depositing at a approved yard fixed by Defence/Local state authority with closed sewage containers complete all as specified. NOTE : (i) Measurement will be as measured at site i,e volume as calculated with actual dimensions before cleaning and after cleaning of sludge/solid materials as available (Pumping/ removal of floating materials as required and work in foul places is included).The rates are deemed to be included for necessary safety equipments, tools and plants, complete all as specified and directed by Engr-in-charge. (ii) Rates quoted be deemed inclusive of closing drain/pipe/manholes with gunny bags etc. to stop incoming sewage during cleaning.

200

-

-

... More
Excavation in trenches n.exc 1.5 m wide & depth exc 1.5 m but n.exc 3.00 M for foundations, sewage lines etc. and n.exc 10 Sqm on plan for manholes and getting out in hard/dense soil

50

-

-

... More
Cleaning of Chocked Sewage lines manually by taking out accumulated sludge and all foreign material complete including pumping/ removal of floating materials as required and work in foul places etc. The rates are deemed to be included for necessary safety equipments, tools and plants, and removing the same to a distance outside of MOD land and depositing at a approved yard fixed by Defence/Local state authority with closed sewage containers complete all as specified.

-

-

-

... More
M&L for Rendering in cement mortar 1:4, 15mm thick on brick walls or concrete finished even and smooth, (without using extra cement) as external surfaces of manholes as complete all as specified and directed by Engr-in-charge.

80

-

-

... More
M&L for cement concrete bed to drain pipes, 300mm dia including forming cradles in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) complete all as specified and directed by Engr-in-charge. NOTE :- Pipe shall be measured and paid separately) as in repairs.

-

-

-

... More
Cleaning of PVC/CI sewer/sludge pipe from floor trap,PVC bend to gully trap/manholes of first floor.

20

-

-

... More
S&F in repairs, PVC (SWR) branch pipe, 110mm dia single (single ‘Y’) equal or un equal with access door complete all as specified and directed by Engr-in-charge.

5

-

-

... More
All as per item No. 5 here-in-before but depth exc 4.5 m but n.exc 6.00 M in hard/dense soil

50

-

-

... More
Cleaning of Chocked Sewage lines mechanically using necessary tools/auger/jetting machine etc. as essential and taking out accumulated sludge and all foreign material from adjoining manhole complete including pumping/ removal of floating materials as required and work in foul places etc. The rates are deemed to be included for necessary safety equipments, tools and plants, and removing the same to a distance outside of MOD land and depositing at a approved yard fixed by Defence/Local state authority with closed sewage containers complete all as specified and directed by Engr-in-charge.

-

-

-

... More
Depth of manholes exc 4.50 mtr and n.exc 6.00 mtr

300

-

-

... More
M & L Cement concrete 1:3:6 in foundations, filling and mass concrete complete all as specified and directed by Engr-in-charge.

2

-

-

... More
M&L for RCC NP-2 drain pipe 150 mm internal dia, grade ‘A’ laid in trenches and Collar/push joint complete all as specified and directed by Engr-in-charge.

-

-

-

... More
Surface dressing n exc 15 cm deep in any type of soil incl removal of bushes/plants / girth n exc 30 cm complete all as specified and directed by Engr-in-charge.

200

-

-

... More
Demolition and breaking up any sewage drain pipe not exceeding 300mm bore dia set in cement mortar including haunching complete all as specified and directed by Engr-in-charge.

100

-

-

... More
S&F in repairs PVC (SWR) bend any radius, 110 mm dia with access door.

10

-

-

... More
M&L for cement concrete bedding and haunching against the sides of pipes after they are laid to 150mm bore drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) laid to falls including packing under, and tested, complete all as specified and directed by Engr-in-charge. NOTE :- Pipe shall be measured and paid separately)

-

-

-

... More
S & Fixed in repairs PVC (SWR) pipes 110mm bore confirming to IS-13592-1992 type 'B' single socketed, in any length with rubber ring joints fixed to walls with PVC clamp complete all as specified and directed by Engr-in-charge.

40

-

-

... More
M&L for cement concrete bedding and haunching against the sides of pipes after they are laid to 450mm bore drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) laid to falls including packing under, and tested, complete all as specified and directed by Engr-in-charge. NOTE :- Pipe shall be measured and paid separately).

-

-

-

... More
S&F in repairs 110 mm dia PVC (SWR) junction single (T-Junction) equal or un equal with access door complete all as specified and directed by Engr-in-charge.

5

-

-

... More
Demolition and breaking up any sewage drain pipe not exceeding 450mm bore dia set in cement mortar including haunching complete all as specified and directed by Engr-in-charge.

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.